For specific models only.
|
|
- Daniel Ray
- 7 years ago
- Views:
Transcription
1 For specific models only.
2 Description Exploded view Specification & echnical Data Description Exploded view Specification and Material of Construction echnical Data Description Exploded View Specification and Material of Construction echnical Data Cable selection table Conversion table 0 2
3 - = Water filled = Resin filled encapsulated = Non-toxic fluid filled NOMINAL MOOR DIA = ", 4 = 4", 6 = 6", 8 = 8", 0=0" ype = A/B/N his digit is only applicable for -Phase "R" Series motors without Lightning Arrestor. N = Ph / CSCR type / wire / 50Hz = Ph / PSC / wire / 50Hz = Ph / PSC / 2 wire / 50Hz = Ph / S.D. / 50Hz = Ph / DOL / 50Hz kw = 0.7, = 0.55, =., =, =, = 8.5, = 00, = 25
4
5 hese oil filled motors are one among the proven & successful products from the house of C.R.I. hese motors are developed with due diligence complying with all safety standards and giving importance to the customers' need. All the components that are in contact with water is made of AISI 04 stainless steel and the motor is pre-filled with edible grade oil which acts as coolant as well as lubricant and heat dissipation media. he freezing point of the oil used is -0 deg C. Dynamically balanced rotors and equipped with quality ball bearings maintain uniform clearance thereby giving better efficiency and increase the life cycle. Up to.0 kw 2 and from.7 kw ball bearings are used to withstand the high axial load. he lower ball bearings are of angular contact type. he shaft extension is made of 00 series stainless steel to avoid splines worn-out. High quality carbon/ceramic mechanical seal and oil seal made of Nitrile rubber are used to ensure better sealing system. For easy maintenance & safe handling plug-in type removable cable leads are provided. It is mandatory to use CRI control box for all ph motors and adequate control & protection system is required for all ph motors. Mounting dimensions of these motors are in accordance with NEMA standard. High operating efficiency and lesser power consumption Extremely hard wearing ball & angular contact bearings Filled with edible grade oil Can be easily dismantled and repaired hese prime mover submersible motors are suitable to couple with deepwell submersible pump ends, used for irrigation, domestic water supply, fountains, industrial water supply, pressure boosting units, ponds, gardens, sprinkler systems and mining. Housing Shell SS 04 Stator Shell S.S - 04 Bearings Shaft Lip Seal / Oil Seal Mechanical seal Diaphragm Upper : Ball Bearing Lower : Angular contact ball Bearing (upto kw- No.) & from.7 kw - 2 No.s 7-4 PH Nitrile Rubber (NBR) Carbon / Ceramic Nitrile Rubber (NBR) 7
6 Nominal Diameter : Series Motor Base Diaphragm 0.06 Snap Ring 0.2 Motor Base op Lower Housing Guide Bush Rotor Upper Housing 4.07 Upper Housing Shell Cable Grommet Sand Guard-Rubber Cable Plug Shell Cable Clamp 6.00 Mechanical Seal Motor Frame 2.08 Oil Seal 2.09 O-Ring 2.2 Screw Stud 2.6 Washer 2.8 Bearing 8.02 Cable Plug/Pin Assembly 8
7 Nominal Diameter : Series Nominal Dia Power range Speed Version Class of Insulation Degree of Protection Direction of Rotation ype of Duty Down hrust Load Minimum cooling flow along the motor Maximum liquid temperature Maximum immersion depth Starts per hour Shaft Mounting Standard Method of Starting Cable Lead out 4 (00mm) 0.7 kw to 2.2 kw Single Phase 0.7 kw to kw hree Phase 2900 rpm Single Phase 20 V, 50 Hz, A.C Supply hree Phase 400 V, 50 Hz, A.C Supply F IP 68 CCW - Single Phase Electrically Reversible - hree Phase S (Continuous) N (0.7 to. kw) 4000 N ( to.0 kw) 6500 N (.7 to kw) 0.5 m/sec O C 50 m 20 Splined as per NEMA standard NEMA Standard Single Phase: Permanent Split Capacitor (PSC) hree Phase: Direct on line (DOL) wire removable type EPDM rubber flat cable L4A-0N L4A-05N L4A-07N L4A-N L4A-5N L4A-22J L4A-0J L4A-7J L4A-40J L4A-55J L4A-75J L4A-0N L4A-05N L4A-07N L4A-N L4A-5N L4A-22J L4A-0J L4A-7J L4A-40J L4A-55J L4A-75J Single Single Single Single Single hree hree hree hree hree hree
8 hese motors are hermetically sealed, encapsulated and water lubricated type with removable cable lead out. he stator windings are of enameled copper wire and the wound stator is mounted in a stainless steel shell and is completely protected by a stainless steel cylinder and stator room is pre-filled with resin. he resin filled in the space between the stator & the stainless steel cylinder dissipates heat quickly resulting in longer motor life. Except stator, other portions of the motor is pre-filled with deionised water containing propylene glycol (anti-freeze agent) which serves as coolant & lubricant for rotor, bushes and thrust bearing. If any leakage of water is observed bring to the notice of the distributor. Dynamically balanced rotors of these motors maintain uniform clearance thereby giving better efficiency and increase the life cycle of the water lubricated bush bearings. Specially designed high performance thrust bearings are used that can withstand high axial thrust loads and upthrust loads with minimum wear and tear. he unique design of thrust bearings creates a wedge of water between the shoe and the disc and thereby providing better water lubrication and increases the life cycle of the thrust bearings. Pressure equalizing rubber diaphragm is provided to guard the pressure and volume variations due to thermal expansion of the water inside the motor. Motor sealing are made by means of O rings. Shaft seals and sand guard prevents ingress of well water, sand and fiber particles into the motor. Care should be taken to ensure that the motor does not run when it is not submerged in the water. o prevent the motor dry running, install water level monitor / dry run preventor. he motor needs a constant flow of water past it s body to keep it at correct operating temperature. Ideally, the motor should be set just below the level at which water enters the bore well. When this level is not ascertained, fit a flow inducer pipe over the pumpset to ensure adequate cooling. It is mandatory to install C.R.I Control box for all single phase wire motors. All Ph motors require an adequate motor protection control panel. Mounting dimensions of motors are in accordance with NEMA standards. Corrosive resistant stainless steel body. Specially designed thrust bearing to withstand high axial thrust loads. Copper rotors and low watt loss silicon steel laminations for higher starting torque. Higher power factor resulting in lesser power consumption. Larger shaft diameter for better power transmission. High heat dissipation for better life cycle. hese prime mover submersible motors are suitable to couple with deepwell submersible pumpends used for Irrigation, Domestic water supply Fountains Industrial water supply Pressure boosting units Ponds, Gardens Sprinkler systems and mining 0
9 Nominal Diameter : Series 0.02 Diaphragm 0.0 Diaphragm Bottom Plate Capacitor Chamber hrust Base hrust Pad Rocker Screw Lower Housing Bush-Carbon Rotor Up hrust Washer Upper Housing Cable Grommet Sand Guard-Rubber Sand Guard-SS/Bakelite 4.07 Upper Housing Shell Motor Frame 2.00 Bolt Key Nut 2.08 Oil Seal 2.09 O-ring Screw Stud Washer
10 Nominal Diameter : Series 0.00 Motor Base Diaphragm Diaphragm Bottom plate hrust Base hrust Pad Rocker Screw Lower Housing Bush-Carbon.00 Rotor Up hrust Washer Upper Housing 4.0 Cable Grommet Sand Guard-Rubber Sand Guard-SS/Bakelite 4.07 Upper Housing Shell Motor Frame Bolt 2.05 Key 2.07 Nut Oil Seal O-ring 2.2 Screw Stud 2.6 Washer 2
11 Nominal Diameter : Series Motor Base Diaphragm Doom Nut hrust Base hrust Base Housing hrust Pad Rocker Cap Rocker Screw Lower Housing Rotor Up hrust Washer Upper Housing Sand Guard-Rubber 4.05 Sand Guard-SS/Bakelite Cable Plug Shell Cable Clamp Motor Frame Circlip Key Nut Oil Seal O-ring 2.2 Screw Stud 2.6 Washer Cable Grommet Bush - Carbon
12 Nominal Diameter : Series Nominal Dia Maximum Outer Diameter Power Range Speed Versions Class of Insulation Degree of Protection Direction of Rotation ype of Duty Down hrust Load Minimum Cooling Flow Along the Motor Maximum emperature of Liquid Starts per Hour Shaft Mounting Standard Method of Starting Cable Leadout 96 mm (max.) 07 kw to. kw - Single Phase 2 wire 0.7 kw to 2.2 kw - Single wire Incorporated with hermal Protector upto. kw Incorporated with Lightening arrestor upto kw 0.7 kw to 5.5 kw - hree phase wire 2900 rpm Single Phase - 20 V, 50 Hz, A.C. Supply hree Phase - 45 V, 50 Hz, A.C. Supply F IP 68 CCW - Single Phase Electrically Reversible - hree Phase S (continuous) 0.7 kw to kw lbs / N 2.2 kw to 5.5 kw - 500lbs / 6500N 0.5 m/sec O C 20 times Splined as per NEMA standard NEMA Standard Single Phase - Capacitor Start Capacitor Run (CSCR) Permanent Split Capacitor (PSC) hree Phase - Direct On Line (DOL) 2 & Wire Removable type EPDM rubber flat Cable Housings Shell S.S - 04 Stator Shell S.S - 04 hrust Pad Carbon Graphite hrust Base S.S 'O' Ring Nitrile rubber (NBR) Diaphragm Nitrile rubber (NBR) Motor Base S.S Capacitor Chamber hermoplastic (2 Wire) 4
13 Nominal Diameter : Series R4A-0M R4A-05M R4A-07M R4A-M Wire Motor Dimensional Drawing R4A-0M R4A-05M All dimensions are in mm Splined shaft 4 eeth - module 875 O Pressure angle 0 A.N.S.I.B Coupling Class 5 R4A-07M R4A-M : - P / 20V / 2 Wire / Permanent Split Capacitor ype (PSC) 5
14 Nominal Diameter : Series R4A-0S R4A-05S R4A-07S R4A-S R4A-5S R4A-22S R4A-0 R4A-05 R4A-07 R4A- R4A-5 R4A-22 R4A-0 R4A-7 R4A-40 R4A * : - P / Wire / 20 V / Capacitor Start Capacitor Run (CSCR) - P / Wire / 45 V / D.O.L. R4A-0S R4A-0 R4A-05S R4A-05 R4A-07S R4A-07 R4A-S R4A- R4A-5S R4A-5 R4A-22S R4A-22 NA NA NA R4A-7 R4A-40 R4A-55 "NA" denotes not available NA NA NA NA NA NA
15 Nominal Diameter : Series hese motors are eco-friendly wet type, water filled rewindable. he stator windings are of water proof synthetic film insulated copper winding wires. It features water lubricated thrust and journal bearings. Motor is pre-filled with clear, cold, pure, fresh, filtered water. However, on request motors can be pre-filled with water and propylene glycol (Anti-freeze agent) for places where the temperature is below the freezing conditions. Before commissioning, ensure the pre-filled level of water inside the motor. If any loss of volume is noticed, refill with clear, cold, pure, fresh, filtered water, through water filling plugs / valves provided in the upper housing. Where the use of anti-freeze agent mixed water is not be allowed for special applications, these motors can also be filled with clear, cold, pure, fresh, filtered water and operated. Dynamically balanced rotors of these W series motors maintain uniform clearance thereby giving better efficiency and increase the life cycle of the water lubricated bush bearings. Specially designed high performance thrust bearings are used that can withstand high axial thrust loads and up thrust loads with minimum wear and tear. he unique design of thrust bearings creates a wedge of water between the shoe and the disc, and thereby providing better water lubrication and increases the life cycle of the thrust bearings. Pressure equalizing rubber diaphragm is provided to guard the pressure and volume variations of the water inside the motor. Motor sealing are made by means of O rings. Shaft seals and sand guard prevents ingress of well water. sand and fiber particles into the motor. Care should betaken to ensure that the motor does not run when it is not submerged in the water, o prevent the motor from dry running, install water level monitor/dry run preventor. he motor needs a constant flow of water past it s body to keep it at correct operating temperature. Ideally, the motor should be set just below the level at which water enters the bore well. When this level is not ascertained, fit a Flow inducer pipe over the pumpset to ensure adequate cooling. It is mandatory to install a C.R.I. Control box for all single phase wire motors. Mounting dimensions of motors are in accordance with NEMA standards. Corrosive resistant stainless steel body. Specially designed thrust bearing to withstand high axial thrust loads. Copper rotors and low watt loss silicon steel laminations for higher starting torque. Higher power factor resulting in lesser power consumption. Larger shaft diameter for better power transmission. hese prime mover submersible motors are suitable to couple with deepwell submersible pumpends used for Irrigation, Domestic water supply Fountains Industrial water supply Pressure boosting units Ponds, Gardens Sprinkler systems and mining 7
16 Motor Base Diaphragm Diaphragm Bottom Plate hrust Base hrust Pad Rocker Screw Lower Housing Bush-LB Guide Bush Rotor Upper Housing Cable Grommet Sand Guard-Rubber Upper Housing Shell Wound Stator Outer Shell Bolt Key Oil Seal O-ring Screw Stud Washer 2.9 O-Ring 8
17 0.00 Motor Base 0.02 Diaphragm Doom Nut hrust Base.0.06 hrust Base Housing hrust Segment.09 Rocker Screw Lower Housing Bush-LB Lower Housing Pipe Rotor Counter hrust Pad 4.00 Upper Housing 4.0 Cable Grommet Sand Guard-Rubber Upper Housing Pipe 4.07 Upper Housing Shell 24.0 Wound Stator 2.0 Circlip 2.05 Key Nut Oil Seal O-ring 2.2 Screw Stud Washer Gasket 2.22 ie Bolt 9
18 Motor Base Diaphragm Diaphragm Bottom Plate Diaphragm Plate Doom nut hrust Base hrust base Housing hrust Pad hrust Segment Rocker Cap Rocker Lock nut Rocker Screw Lower Housing Bush-Carbon Supporting Ring Rotor Up hrust Washer Upper Housing Cable Grommet Cable Winding Guard Circlip Key Nut Oil seal O-ring 2. Plug 4.02 Cable Grommet Lock Plate 2.2 Screw 4.04 Sand Guard -Rubber Stud Sand Guard-SS/Bakelite Oil seal Housing Wound Stator Washer Gasket ie Bolt 20
19 Sand Guard Shaft Seal Guard Water Filling Plug / Drain Plug Shaft Seal Upper Housing Nut Cable Grommet Grommet Plate Gasket Stator Winding Cable Body Rotor Circlip Lower Housing Counter hrust Pad ie-bolt hrust Bearing Pad hrust Bearing Base Rocker Screw Rocker Screw Nut Rocker Cap Segment Shell hrust Segment Half Round Guide Pad Key Motor Base Diaphragm Doomnut 'o' Ring Diaphragm Plate Bolt Oil Seal Housing Oil Seal Housing Gasket 2
20 Nominal Diameter : Series Nominal Dia Maximum Outer Diameter Power Range Speed Versions Class of Insulation Degree of Protection Direction of Rotation ype of Duty Maximum Down hrust Load Minimum emperature of Liquid Maximum emperature of Liquid Starts per Hour Shaft Mounting Standard Method of Starting Cable Leadout mm (max.) 0.7 kw to 2.2 kw - Single Phase (Incorporated with hermal Protector) 0.7 kw to kw - hree Phase 2900 rpm Single Phase - 20 V, 50 Hz, A.C. Supply hree Phase V, 50 Hz, A.C. Supply Y IP 58 CCW - Single Phase Electrically Reversible - hree Phase S (continuous) 0.7 kw to. kw lbs / N kw to 4.0 kw lbs / 4000 N 5.5 kw to kw lbs / 6500 N 0.5 m/sec O C 20 times Splined as per NEMA standard NEMA Standard Single Phase - Capacitor Start Capacitor Run (CSCR) hree Phase - Direct On Line (DOL) Permanently Connected and Sealed /4 core EPDM rubber Flat Cable Shaft Seal Nitrile rubber (NBR) Housing Sell S.S - 04 Stator Shell S.S - 04 hrust Pad Carbon Graphite hrust Base S.S Diaphragm Nitrile rubber (NBR) Motor Base S.S - 04 ype 'N' motors are available upto. kw 22
21 Nominal Diameter : Series W4A-0S W4A-05S W4A-07S W4A-S W4A-5S W4A-22S W4A-0 W4A-05 W4A-07 W4A- W4A-5 W4A-22 W4A-0 W4A-7 W4A-40 W4A-55 W4A W4A-0S W4A-05S W4A-07S W4A-S W4A-5S W4A-22S S S S S S S W4A-0 W4A-05 W4A-07 W4A- W4A-5 W4A-22 W4A-0 W4A-7 W4A-40 W4A-55 W4A * : - P / 20 V / CSCR ( Wire) - P / D.O.L. / 45V
22 Nominal Diameter : Series Nominal Dia Maximum Outer Diameter Power Range Speed Versions Class of Insulation Degree of Protection Direction of Rotation ype of Duty Maximum Down hrust Load Minimum cooling flow along the motor Maximum emperature of Liquid Starts per Hour Shaft Mounting Standard Method of Starting Cable Leadout 6" (50mm) 44 mm (max.) 2.2 kw to 45 kw - hree Phase 2900 rpm hree Phase V, 50 Hz, A.C. Supply Y IP 68 Electrical Reversible - hree Phase S (continuous) 2.2 kw to 22 kw lbs / 5500 N 26 kw to 45 kw lbs / N 0.5 m/sec O C 20 times Splined as per NEMA standard NEMA Standard 2.2 kw to 45 kw Direct On Line (D.O.L.) 5.5 kw to 45kW Star Delta (S.D.) Permanently Connected and Sealed /4 core EPDM Rubber Flat Cable Optional: On request motors can be supplied with P sensors and PE2 windings. Shaft Seal / Nitrile Rubber (NBR) Nitrile Rubber (NBR) Mechanical Seal Ceramic - Carbon Ceramic - Carbon Housings Shell S.S - 04 Cast Iron Stator Shell S.S - 04 S.S - 04 hrust Pad Carbon Graphite Carbon Graphite hrust Base S.S Cast Iron Dhaphragm Nitrile Rubber (NBR) Nitrile Rubber (NBR) Motor Base S.S - 04 Cast Iron 24
23 Nominal Diameter : Series W6A-22 W6A-0 W6A-7 W6A-40 W6A-45 W6A-55 W6A-75 W6A-9 W6A-0 W6A-0 W6A-50 W6A-85 W6A-220 W6A-260 W6A-00 W6A-70 W6A W6A-55D W6A-75D W6A-9D W6A-0D W6A-0D W6A-50D W6A-85D W6A-220D W6A-260D W6A-00D W6A-70D W6A-450D Dimensional Drawing W6A-22 W6A-0 W6A-7 W6A-40 W6A-45 W6A-55 W6A-75 W6A-9 W6A-0 W6A-0 W6A-50 W6A-85 W6A-220 W6A-260 W6A-00 W6A-70 W6A P / DOL / 45V W6A-55D W6A-75D W6A-9D W6A-0D W6A-0D W6A-50D W6A-85D W6A-220D W6A-260D W6A-00D W6A-70D W6A-450D P / SD / 45V
24 Nominal Diameter : Series Nominal Dia Maximum Outer Diameter Power Range Speed Versions Class of Insulation Degree of Protection Direction of Rotation ype of Duty Maximum Down hrust Load Minimum cooling flow along the motor Maximum emperature of Liquid Starts per Hour Shaft Mounting Standard Method of Starting Cable Leadout 94 mm 7-9 kw 2900 rpm hree Phase V 50 Hz, A.C. Supply Y IP 68 Electrically Reversible - three Phase S (continuous) 0000 lbs / N 0.6 m/sec O C 0 times Splined as per NEMA standard NEMA Standard 7 kw to 9 kw (D.O.L. & SD) Permanently Connected and Sealed /4 core Rubber insulated Flat Cable Optional: On request motors can be supplied with P sensors and PE2 windings. Shaft Seal Housing S.S Casted Cast Iron Shaft Seal / Nitrile Rubber (NBR) Nitrile Rubber (NBR) Mechanical Seal Ceramic - Carbon Ceramic - Carbon Upper & Lower Housings S.S Cast Iron Stator Shell S.S - 04 Cast Iron hrust Pad Carbon Graphite Carbon Graphite hrust Base S.S S.S Diaphragm Nitrile Rubber (NBR) Nitrile Rubber (NBR) Motor Base S.S Casted Cast Iron * Shaft Seal Housing S.S Casted only applicable for type -A motors. 26
25 Nominal Diameter : Series W8B-70 W8B-70D 7 W8B-450 W8B-450D 45 W8B-550 W8B-550D 55 W8B-60 W8B-60D 6 W8B-750 W8B-750D 75 W8B-90 W8B-90D W8B-70 W8B-450 W8B-550 W8B-60 W8B-750 W8B-90 W8B-70D W8B-450D W8B-550D W8B-60D W8B-750D W8B-90D P / DOL / 80-45V P / SD / 80-45V
26 Nominal Diameter : Series Nominal Dia Maximum Outer Diameter 2 mm Power Range 8 to 85 kw - hree Phase Speed 2900 rpm Versions hree Phase V 50 Hz, A.C. Supply Degree of Protection IP 68 Direction of Rotation Electrically Reversible - three Phase ype of Duty S (continuous) Maximum Down hrust Load N Starts per Hour 0imes Shaft Splined as per NEMA standard Mounting Standard NEMA Standard Method of Starting D.O.L. & S.D. Optional: On request motors can be supplied with P sensors and PE2 windings. Shaft Seal / Mechanical Seal Nitrile Rubber (NBR) Ceramic - Carbon Stator Shell S.S - 04 Mechanical Seal Ceramic Carbon hrust Bearing S.S. 420 hrust Base Antimony Carbon hrust Base Housing GG 22 Diaphragm NBR - EPDM Motor Base GG 22 * Shaft Seal Housing S.S Casted only applicable for type -A motors. 28
27 Nominal Diameter : Series W0B-80 W0B-80D W0B-920 W0B-920D W0B-A0 W0B-A0D W0B-A29 W0B-A29D W0B-A47 W0B-A47D W0B-A66 W0B-A66D W0B-A85 W0B-A85D W0B-80 W0B-80D 8 0 /D W0B-920 W0B-920D /D W0B-A0 W0B-A0D 0 50 /D W0B-A29 W0B-A29D /D W0B-A47 W0B-A47D /D W0B-A66 W0B-A66D /D W0B-A85 W0B-A85D /D
28 hese are maximum length of cable in MERES from POWER SOURCE to MOOR. Exceeding these length will void warranty. 0
29 hese are maximum length of cable in MERES from POWER SOURCE to MOOR. Exceeding these length will void warranty.
30 x x 0, x x x x X x x x x x Kilometer = 000 metres = miles mile = metres = kilometers (cwt) x x x x emperature Celsius, tc emperature Fahrenheit, tf emperature Celsius, tc emperature Fahrenheit, tf emperature Kelvin, tk emperature Kelvin, tk emperature Kelvin, tk emperature Kelvin, tk emperature Fahrenheit, tf emperature Celsius, tc emperature Celsius, tc emperature Fahrenheit, tf K = tc + 2 K = (tf /.8) F =.8 tc + 2 C = (tf - 2) /.8 C = tk - 2 F =.8tk
31
The conditions below apply to the curves shown on the following pages.
GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves
More informationCDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
More informationJOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.
Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
More informationKTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet
KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429
More informationSeries description: Wilo-Drain TC 40
Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site
More information300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS
Section: MOYNO 500 PUMPS Page: 1 of 8 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Mechanical Seal Models Packing Gland Models MODELS DESIGN FEATURES
More information4" SUBMERSIBLE PUMPS
4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant
More informationVolkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)
19 Engine - Cooling System (Page GR-19) Cooling system draining and filling general information Body components, layout Engine components, layout Radiator fan run-on checking Recommended mixture ratios
More informationPump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More information1/29/2008 DR70. Baja Motorsports Inc. P.O. Box 61150 Phoenix, AZ 85082 Toll Free: 888-863-2252 PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 43
DR70 Toll Free: 888-863-2252 PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 43 CYLINDER & CYLINDER HEAD 1 DR70-001 883099044472 CYLINDER 1 1 2 DR70-002 883099044489 GASKET, CYLINDER 1 1 3 DR70-003 883099044496
More information1/29/2008 DR50. Baja Motorsports Inc. P.O. Box 61150 Phoenix, AZ 85082 Toll Free: 888-863-2252 PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 45
DR50 Toll Free: 888-863-2252 PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 45 CYLINDER & CYLINDER HEAD Part UPC Number Description Baja Description 1 DR50-001 842645074424 CYLINDER 1 1 2 DR50-002 842645074431
More informationDR90. Baja Motorsports Inc. P.O. Box 61150 Phoenix, AZ 85082 Toll Free: 888-863-2252 PART NUMBERS AND PRICES ARE SUBJECT TO CHANGE 1 of 51
DR90 Toll Free: 888-863-2252 PART NUMBERS AND PRICES ARE SUBJECT TO CHANGE 1 of 51 CYLINDER & CYLINDER HEAD 1 DR90-001 842645048166 CYLINDER 1 1 2 DR90-002 842645048173 GASKET, CYLINDER 1 1 3 DR90-003
More informationTECHNICAL INFORMATION Bulletin
Peerless Pump Company 2005 Dr. M.L. King Jr. Street, P.O. Box 7026, Indianapolis, IN 46207-7026, USA Telephone: (317) 925-9661 Fax: (317) 924-7338 www.peerlesspump.com www.epumpdoctor.com TECHNICAL INFORMATION
More informationAn SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps
An SPX Process Equipment Operation Universal II Industrial Series Rotary Positive Displacement ECP Pumps New levels of performance. Reduced operational and maintenance costs. For more than half a century,
More information1/29/2008 DR125 / DR150. Baja Motorsports Inc. P.O. Box 61150 Phoenix, AZ 85082 Toll Free: 888-863-2252 PARTS AND PRICES ARE SUBJECT TO CHANGE 1 of 55
DR125 / DR150 Toll Free: 888-863-2252 PARTS AND PRICES ARE SUBJECT TO CHANGE 1 of 55 CYLINDER HEAD ASSY. 1 125-001 883099006937 CYLINDER HEAD COVER 1 1 2 125-002 883099006944 BOLT M6X28 2 3 3 125-003 883099006951
More informationDR90. Baja Motorsports Inc. P.O. Box 61150 Phoenix, AZ 85082 Toll Free: 888-863-2252 PART NUMBERS AND PRICES ARE SUBJECT TO CHANGE 1 of 51
DR90 Toll Free: 888-863-2252 PART NUMBERS AND PRICES ARE SUBJECT TO CHANGE 1 of 51 CYLINDER & CYLINDER HEAD Part UPC Number Description Baja Description 1 DR90-001 842645048166 CYLINDER 1 1 2 DR90-002
More informationTECHNICAL SPECIFICATION
THOMAS - G-FLEX GFLEX TECH SPEC CONNECTING INNOVATION JOHANNESBURG TEL: +27 11 794 7594 CAPE TOWN TEL: +27 21 556 5258 POLOKWANE TEL: 015 298 9142 DESIGNER, MANUFACTURER AND DISTRIBUTOR OF PIPE CONNECTION,
More informationSIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
More informationFlygt 3068, 50Hz. Technical Specification
Flygt 3068, 50Hz Technical Specification Table of Contents Table of Contents B-pump...2 Product description...2 Motor rating and performance curves...4 C-pump...6 Product description...6 Motor rating
More informationCRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
More informationCRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
More informationMaintenance and Service Instruction
Screw pumps E4 Maintenance and Service Instruction E4 1 IMO AB This instruction is valid for all E4 pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationMDT5N25 & MTD5N40 SERVICE PARTS
MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts
More informationDR50 Hensim Dirt Runner 49cc Dirt Bike (VIN PREFIX LLCH or LUAH)
Page 1 of 21 Product Information Baja Web > Product Information > Parts Lists > DIRTBIKE > DR50 Hensim Dirt Runner 49cc Dirt Bike (VIN PREFIX LLCH or LUAH) DR50 Hensim Dirt Runner 49cc Dirt Bike (VIN PREFIX
More information4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves
1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire
More informationVolkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
More informationHorizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
More informationDR125 and DR150 Hensim Dirt Runner 125cc and 150cc Dirt Bike (VIN PREFIX LLCH or LUAH)
Parts Lists - DR125 and DR150 Hensim Dirt Runner 125cc and 150cc Dirt Bike (VIN PR... Page 1 of 25 Product Information Baja Web > Product Information > Parts Lists > DIRTBIKE > DR125 and DR150 Hensim Dirt
More informationDrive shaft, servicing
Volkswagen Passat B6 - Drive shaft, servicing Стр. 1 из 41 40-7 Drive shaft, servicing Drive shafts, overview I - Assembly overview: Drive axle with CV joint VL100 40-7, Drive axle with CV joint VL100,
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationSECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationMODEL 300505 INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.
More informationWorld Bridge Replacement Parts for EMD 567 and 645 Diesel Engines
40000927-WB REPAIR KIT, WATER PUMP 40005124-WB MAIN & ROD BEARING KIT, 16 CYLINDER 40005125-WB MAIN & ROD BEARING KIT, 20 CYLINDER 40006129-WB PISTON, 645E HTG AND TIN PLATED 40006130-WB PISTON, 645 E3
More informationCompact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw.
Compact pumps from the wastewater experts FLYGT 304, 307, 3068. Power range 0.7.4 kw. Wastewater is unpredictable, Flygt pumps are not If you want a wastewater pump that just works month after month, year
More informationMustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
More information2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS
2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature
More informationSolar Collector Series. Product List
Solar Collector Series List FULL COLLECTORS (MANIFOLD, TUBES & ROOF FRAME) : CSR00051 Apricus Collector : AP10 10-Way Manifold, 10 Tubes and Standard Roof Frame CSR00052 Apricus Collector : AP20 20-Way
More informationPS1800 Centrifugal Pumping Systems
PS1 Centrifugal Pumping Systems General Data and Sizing Tables The curve show the performance range of 4 models at 1Wp solar array - irradiation of 6kWh/m² on a tilted surface - ambient temperature 3 C
More informationLU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions
LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment
More informationTECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
More informationLF-1 CYLINDER HEAD COVER
PITBIKE AB, SWEDEN LIFAN 50cc SOHC parts catalogue Copyright PITBIKE AB, SWEDEN LF- CYLINDER HEAD COVER 5 6 7 8 9 0 5 /P5FMI 0/P5FMI /P50FMH /P5FMI-B /P5FMI /P5FMI 5/P50FMH GB/T9 /P5FMI 5/P5FMI 8/P50FMG
More informationSEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor
INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:
More informationSingle-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
More informationProject: Model: Chk d: Date: Model 32DGUII61.5S
Contents Model 32DGUII6.5S 32DGFU6.5S 32DGFU6.5 50DGFU62.2S 50DGFU62.2 50DGFU63.7S 50DGFU63.7 Section Page Specifications 2-38 Selection Chart 2-38 Performance Curves 2-6 Outline Drawings 2-8 Sectional
More informationVertical Pumps for the Oil & Gas Industry
Vertical Pumps for the Oil & Gas Industry ITT API Expert ITT Commitment ITT is committed to the Oil and Gas market, which is the largest segment of our business. We have been investing in technology to
More informationPRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
More informationMARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. Water supply. Sprinkler irrigation. Pressure boosting. Fire-fighting.
4 Submersible Pumps GS Series MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. APPLICATIONS Water supply. Sprinkler irrigation. Pressure boosting. Fire-fighting. Compact Sturdy Abrasion resistant All components
More informationVolkswagen B3 Passat Manual Transmission 02A 34 Manual Transmission - Controls, Assembly (Page GR-34) 02A 5-speed. Gearshift cable/lever installing
34 Manual Transmission - Controls, Assembly (Page GR-34) 02A 5-speed Gearshift cable/lever installing Gearshift housing repairing Gearshift lever repairing lever/relay lever, installing Gearshift mechanism
More information2" & 3" Poly Wet Seal Pump Instruction Manual
Always place the pump as close to the liquid to be pumped as possible. Keep the suction line short and with few bends. Keep the pump and engine on a level foundation. A poor foundation and a heavy suction
More informationTECHNICAL SERVICE MANUAL
TECHNICAL SERVICE MANUAL HEAVY-DUTY PUMPS SERIES 4195 AND 495 SIZES GG - AL SECTION TSM 144 PAGE 1 of 10 ISSUE D CONTENTS Introduction....................... 1 Safety Information.................... 2
More informationCooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
More informationBaumann 87000 Flexsleev Sanitary Control Valve
Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found
More informationASSEMBLY DIAGRAM AND ASSEMBLY REFERENCE ULTIMA OLD SCHOOL 2 EVO & TC BELT DRIVE UNITS
ASSEMBLY DIAGRAM AND ASSEMBLY REFERENCE ULTIMA OLD SCHOOL 2 EVO & TC BELT DRIVE UNITS BELT DRIVE ASSEMBLIES Part# 58-850 2 Old School Belt Drive Assembly - Polished Part# 58-851 2 Old School Belt Drive
More informationFLANGED END BALL VALVE
Specification: FLANGED END BALL VALVE - Chem Oil s two-piece ball valve has been designed to handle extreme service applications with unsurpassed reliability. Valve body machined from solid wrought material
More informationBR150 Pmi Baja Reaction 150cc Go Kart (VIN PREFIX L4VM)
Page 1 of 21 Product Information Baja Web > Product Information > Parts Lists > GOKART > BR150 Pmi Baja Reaction 150cc Go Kart (VIN PREFIX L4VM) BR150 Pmi Baja Reaction 150cc Go Kart (VIN PREFIX L4VM)
More informationPOSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
More information50Hz SUBMERSIBLE MOTORS APPLICATION INSTALLATION MAINTENANCE
50Hz SUBMERSIBLE MOTORS APPLICATION INSTALLATION MAINTENANCE Commitment To Quality Franklin Electric is committed to provide customers with defect free products through our program of continuous improvement.
More informationTC 170 & TC 170 PD TRANSFER CASE
Automotive Corporation TC 170 & TC 170 PD TRANSFER CASE PARTS MANUAL Fabco Automotive Corporation, Livermore, CA Ph:(925) 454-9500 Fax:(925) 454-9501 1-(800) 967-8838 www.fabcoautomotive.com VII. PARTS
More informationISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24
Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical
More informationNo: 898501 En Revision 02 2009.08. Parts List. MINEX 8101.171 100-110 222 200-21 3
No: 89850 En Revision 02 2009.08 Parts List MINEX 80.7 www.grindex.com 2 3 6 3 5 00-0 7 8 9 5 6 7 20 2 22 6 8 9 0 2 3 5 20 2 22 23 23 2 25 26 27 7 8 9 50 5 52 53 5 220 22 222 200-2 3 55 56 57 28 58 59
More informationMechanical shaft seal types and sealing systems
Chapter 2 Mechanical shaft seal types and sealing systems 1. Mechanical shaft seal types 2. Sealing systems 3. Selecting a mechanical shaft seal Mechanical shaft seal types and sealing systems 1. Mechanical
More informationSJT / SJM / SJP Large Vertical Pumps
SJT / SJM / SJP Large Vertical Pumps The Heart of Your Process SJT, SJM, SJP Large Vertical Pumps Product Overview SJT Turbine Ns 1800 < 5000 nq 35 < 110 SJM Mixed Flow Ns 5800 < 8300 nq 113 < 161 SJP
More informationSelect Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
More informationP498-2 For Model: NL498D2 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators
P498-2 For Model: NL498D2 PARTS CATALOG Marine Generators Marine Diesel Engines Land-Based Generators CALIFORNIA Proposition 65 Warning: Diesel engine exhaust and some of its constituents are known to
More informationKESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water
More informationK&T Saw Shop 606-678-9623 or 606-561-4983
12-600072F PRO MAC 850 SUPER CHAIN SAW 05/92 to Current IPL 215710-R1 Page 1 of 16 Accessories www.ktoutdoor.com 12-600072F PRO MAC 850 SUPER CHAIN SAW 05/92 to Current IPL 215710-R1 Page 2 of 16 Accessories
More informationSTEERING SYSTEM - POWER
STEERING SYSTEM - POWER 1990 Nissan 240SX 1990 STEERING Nissan - Power Rack & Pinion Axxess, Maxima, Pulsar NX, Sentra, Stanza, 240SX, 300ZX DESCRIPTION The power steering system consists of a rack and
More information60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
More informationModel 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com
Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022
More informationIF IT FLOWS THE BOWIE PUMP CAN PUMP IT
IF IT FLOWS THE BOWIE PUMP CAN PUMP IT Bowie Industries, Inc. Bowie, TX 76230 USA Page 1 Bowie Pumps Manual General Pump Information..Page 2 300 Series Pumps.. Page 5 400 Series Pumps.Page 11 500 Series
More informationSubmersible pumps Grundfos With top exit Mop sump pomps Simer en City With top exit Submersible pumps Homa Submersible pumps DAB
Submersible pumps Grundfos With top exit Mop sump pomps Simer en City With top exit Submersible pumps Homa Submersible pumps DAB Grunfos KP sump pump completely made of stainless steel.. Very effective
More informationJames M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
More informationPRINCE 50 Parti di ricambio agg. al 30-11-09
. 缸 头 罩 部 件 CYLINDER HEAD COVER(FOR EUROPE) 50000 COVER COMP HEAD 2 5000 GASKET HEAD COVER 3 50002 Aeration Head Cover 4 50372 AERATION CAP 5 50355 TUBE BREATHER 6 50356 TIE-IN 7 50358 AERATION TUBE ASSY
More informationSERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A
PAGE 1 OF 6 BASE ASSEMBLY 00 0 EXAMPLE: Component Parts (Small #) Are Included When Ordering The Assembly (Large #). SPECIFY CATALOG NO. AND NO. WHEN ORDERING PARTS 1 02-80-0050 Thrust Bearing (1) 2 05-80-0510
More informationStandard offering (pumps)
MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) info@mdmpumps.co.uk
More informationOPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE 215.10
OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE 215.10 To Pump model Pump number Our order Your order Order date Reference Item number Destination Plant Before storing, installation, operation or maintenance
More informationOPERATION & MAINTENANCE MANUAL SUBMERSIBLE SEWAGE PUMP
OPERATION & MAINTENANCE MANUAL SUBMERSIBLE SEWAGE A Mark of Quality CROSS SECTION DRAWING No. DESCRIPTION MATERIAL 01 CABLE PVC. INSU. SHEATHED 02 CABLE PROTECTOR NITRILE RUBBER 03 GLAND COVER C.I. IS-210,
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationTube Type Oil Skimmer Comparison
Process Overview- Tube Type Oil Skimmers Oil flows down the face of the skimmer and into a sludge pan that is plumbed to a barrel. Model BG01 & BG34 or 6V Oil Skimmer 1.0 or 3/4 Diameter Collector Tube
More informationCooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More informationToroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
More informationAC Electric Motors best practice
If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training
More informationAir Vantage 500 Kubota
Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-625 P-625 RETURN TO MAIN INDEX PARTS LIST FOR Air Vantage 500 Kubota P-625-A
More informationELECTRIC MOTOR TEFC OPERATION & MAINTENANCE. meps Approved
SOUTH AUSTRALIA HEAD OFFICE (Accounts / Payments) 34-36 Kinkaid Avenue NORTH PLYMPTON SA 5037 Ph: (08) 8295 5566 Fax: (08) 8295 5533 VICTORIA 23 James Street CLAYTON SOUTH VIC 3169 Ph: (03) 9544 2324 Fax:
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationMODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK
1 565AKHU HYDRAULIC 1.22 O-RING - 2 REQUIRED UNIT 1.23 O-RING COMPLETE 1.24 TEFLON O-RING 2 REQUIRED 1.3 EXTENSION SCREW 1.3A SPRING PIN 1.4 SPRING SUPPORT 1.5 SCREW BUSHING 1.6 Y SHAPE SEAL RING 1.7 HEAD
More informationPSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS
PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS AC AND DC GENERATOR SCHEMATIC ENGINE GENERATOR ASSEMBLY REF Description QTY PSS10 PSS12 1 Engine, Honda GX620K1VXC2 Code 637220 1 99779-000 GX670VXC2 Code 637220
More informationThis is the civilian transfer case with the cooling loop only found in the driven gear half of the front case.
INTRODUCTION The Transfer case used in the AMG Hummer is a New Venture Gear, model 242. This case has been in use for the H-1/Hummer since the early 1990 s. There have been modifications to the internal
More information11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50
11 COOLING SYSTEM SERVICE INFORMATION------------------------------------------------ 11-1 TROUBLESHOOTING----------------------------------------------------- 11-1 RADIATOR ------------------------------------------------------------------
More informationVolkswagen Golf 5 2004-> VW Rabbit GTI 2006->
Стр. 1 из 24 Volkswagen Golf 5 2004-> VW Rabbit GTI 2006-> 19-1 Cooling system components Warning! Hot steam may escape when opening expansion tank. Wear protective goggles and protective clothing to prevent
More informationCooling system components, servicing
19-1 Cooling system components, servicing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate protection, cover the cap
More informationInnovative Products For Unique Applications. A Tradition of Excellence. Creative Engineering for Fluid Systems. Earthquake Proof Valves
A Tradition of Excellence With the development of the first rubber seated butterfly valve more than 70 years ago, the Henry Pratt Company became a trusted name in the flow control industry, setting the
More informationDO NOT attempt to repair hub and wheel bearing assembly.
Page 1 of 6 HUB & WHEEL BEARINGS (WITH PULSE VACUUM HUBLOCK) DO NOT attempt to repair hub and wheel bearing assembly. Removal DO NOT remove hub lock assembly by prying on hub lock legs. This can crack
More informationSIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06
SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz
More informationWATER pressure. Issue 3 / 2014. Clear water pumps for domestic and commercial applications
Issue 3 / 214 WATER pressure PUMPS AND washdown transfer pumps Clear water pumps for domestic and commercial applications Email: enquiries@dlmwallace.co.nz Web: www.dlmwallace.co.nz Auckland: Maurice Road,
More information