Type MS325. Phone: Fax: Web: - Manual motor protectors
|
|
- Charla Washington
- 7 years ago
- Views:
Transcription
1 Manual motor protectors Type MS32 MS Manual motor protectors Type MS32 Thermal setting Single-phase 3-phase Catalog List range horsepower ratings 1 horsepower ratings number price (Amps) 120V 240V 240V 480V 600V MS MS $ MS MS /2 1/2 MS /10 3/4 3/4 MS /6 1/ MS /8 1/ MS /4 1/ MS / MS / MS MS MS MS MS32 UL File #E Accessories UL File #E9033 Single phase motor ratings are based upon wiring all three poles in series. Discount schedule MA
2 Type MS32 UL 08E Manual motor protectors MS Manual motor protectors Type MS32 Thermal setting Single-phase 3-phase Catalog List range horsepower ratings 1 horsepower ratings number 2 price (Amps) 120V 240V 240V 480V 600V MS E MS32-0.2E $ MS E MS E /2 1/2 MS32-1.0E /10 3/4 3/4 MS32-1.6E /6 1/ MS32-2.E /8 1/ MS32-4.0E /4 1/ MS32-6.3E / MS32-9.0E / MS32-12.E MS32-16E MS32-20E MS32-2E 302 MS32 UL File #E Accessories UL File #E9033 Class 10 overload Short circuit rating of 18kA 1 Single phase motor ratings are based upon wiring all three poles in series. 2 Part includes MMP, barrier and trip signal. Discount schedule MA
3 Manual motor protectors Type MS32 Accessories MS32-HK11 Auxiliary contact blocks for Type MS32 (side mount) Auxiliary contact blocks for Type MS32 (front mount) Bell alarm contact blocks for Type MS32 1 NO & 1 NC MS32-HK11 2 NO MS32-HK20 $ 33 2 NC MS32-HK02 1 NO & 1 NC MS32-HKF11 2 NO MS32-HKF20 1 NO MS32-SK10 1 NC MS32-SK01 $ 33 $ 33 MS32-HKF11 Shunt trips for Type MS VAC/VDC, 60 Hz MS32-ST VAC/DC, 60 Hz MS32-ST24 $ 82.0 MS32-UA24 Undervoltage trip for Type MS32 24V MS32-UA24 48V MS32-UA48 60V MS32-UA60 110V MS32-UA110 $ V MS32-UA V MS32-UA400 41V MS32-UA41 480V MS32-UA480 Remote control unit MS32-AS Electrically operated remote control unit for MS32. For use up to MS32-16 and below. Not for use with MS32-20 & MS32-2. Provided with 1 NO & 1 NC auxiliary contacts and 1NO trip signal contacts NOTE: May not be used with HFK, SK, ST or UV accessories 24V AC/DC RC32-24V 48V AC/DC RC32-48V 60V AC/DC RC32-60V $ V AC/DC RC32-110V 230V AC/DC RC32-230V MS32-SA1 MS32-SA3 Supporting terminal for Type MS32 for UA or as N/LS clamp MS32-AS $ 1 Padlocking devices for Type MS32 Adapter for padlock type SA1 MS32-SA1 $ 1.00 Complete padlock kit (includes adaptor, padlock & 3 keys) MS32-SA Discount schedule MA
4 Type MS32 Accessories Manual motor protectors Switch cublicle mounting kit Molded plastic enclosures for Type MS32 Item Protection Catalog List description level number price Light gray enclosure with black handle IP64 OTPA32B2P1 $ 7 Light gray enclosure with red/yellow handle IP64 OTPA32A2P1 7 Gray enclosure w/clear lid, 4 module IP Gray enclosure w/clear lid, 6 module IP Gray enclosure with black handle IP6 IB32-G 7 Yellow enclosure with red handle IP6 IB32-Y 7 NOTE: Use Discount schedule MA for IP64 & IP6 enclosures; use Discount schedule CB8 for IP enclosures. Plastic adaptors for enclosures for Type MS32 PG16 TO 1/2 NPT PG16-1/2 NPT $ 10 MS32-BB1 MS32-SM1 PS3-2-0 PS3-4-0 Selector handles for through-the-door operation for Type MS32 1 Shaft coupler MSMN $ 1 NEMA 1, 3R, 12 black selector handle OHB2AJ 30 NEMA 1, 3R, 12 red/yellow selector handle OHY2AJ length shaft OXSX length shaft OXSX180 6 NOTE: Use Discount schedule MA for shaft coupler; use Discount schedule H6 for handles and shafts. Power feed terminal blocks for Type MS32 Busbars for Type MS32 2 Standard, accepts 4 AWG wire MS32-SM1 $ 24 Low profile, accepts 4 AWG wire MS32-BB1 2.0 for 2 devices; without auxiliary switch PS3-2-0 $ 24 for 3 devices; without auxiliary switch PS for 4 devices; without auxiliary switch PS for devices; without auxiliary switch PS for 2 devices; with 1 auxiliary switch PS for 3 devices; with 1 auxiliary switch PS for 4 devices; with 1 auxiliary switch PS for devices; with 1 auxiliary switch PS for 2 devices; with 2 auxiliary switches PS for 4 devices, with 2 auxiliary switches PS Busbars can be daisy chained to connect additional MS32s. Close coupling adapters Device MS32 + B6/B7 contactor MS32 + VB6/VB7 reversing contactor Catalog number BEA7/32 MS32-VB7 List price $ MS32 + A9, A12, A16 contactor BEA16/ MS32 + A26 contactor BEA26/ AL9 - AL16 BEA16/32AL 14.0 AL26 BEA26/32AL MS32 coupled to mini-contactor UL 08 Type E Accessories Required Device Catalog number List price Line side infeed block S3-M3 $ 30 Short circuit trip signal CK Must have shaft coupler, handle and shaft for through-the-door operation. 2 UL file # E16720; CSA file# LR98427M7-11
5 Manual motor protectors Technical data Type MS32 Short circuit ratings Short circuit ratings MS32 Group installation short circuit ratings 480V 1 600V 2 Short Circuit Maximum Fuse Range rating size ka, 600VAC A MS32 ka 30 ka 0 ka 8kA Current Fuse MCCB Fuse MCCB Fuse MCCB Fuse range A A A A S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S4H S7H S7H S4H S7H S7H S4H S7H S7H S4H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S4H S7H S7H S7H S7H S7H S4H S7H S4H20 1 Fuse: Rated 1600A, Listed Class L. All others, listed RK. Both time delay fuses. 2 Fuse: Rated 1600A, Listed Class L. All others, listed K. Both time delay fuses.
6 Technical data Type MS32 Short circuit protection Manual motor protectors Short-circuit protection MS32 Setting ranges, short-circuit strength and max. back-up fuses Maximum rated current of the short-circuit fuses if I at at at at at from to 230 V AC 400 V AC 440 V AC 00 V AC 690 VAC I cs gl, am I cs gl, am I cs gl, am I cs gl, am I cs gl, am ka A ka A ka A ka A ka A A A Fuse types: Diazed, l.v.h.b.c., utilisation categories: gl, am (VDE), gl/gg (IEC) Setting ranges to Short-circuit proof No back-up fuse required up to I cc = 100 ka / cc > I cs Short-circuit protection MS32 Setting ranges, short-circuit strength and max. back-up fuses Setting ranges Maximum rated current of the short-circuit fuses if I cc > I cs at at at at at from to 230 V AC 400 V AC 440 V AC 00 V AC 690 VAC I cs gl, am I cs gl, am I cs gl, am I cs gl, am I cs gl, am ka A ka A ka A ka A ka A A A Fuse types: Diazed, l.v.h.b.c., utilisation categories: gl, am (VDE), gl/gg (IEC) to Short-circuit proof No back-up fuse required up to I cc = 0 ka / I cs = Rated service short-circuit breaking capacity, I cu = Rated ultimate short-circuit capacity, I cc = Prospective short-circuit current at installation location. I cs = I cu in the case of MS 32 and MS 116!
Manual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationTechnical Catalogue. Manual Motor Starters MS116, MS325, MS4xx ABB
Technical Catalogue Manual Motor Starters MS116, MS325, MS4xx ABB 1 ABB Manual Motor Starters Type Series M up to 45 kw (400 V AC) Contents Manual Motor Starter MS116 0-16 A, 16/50 ka... 6 Manual Motor
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More informationGeneral information Circuit breakers for power distribution T1 T3
Circuit breakers for power distribution T1 T3 T1 T2 T3 T1 1P T1 T2 T3 UL 489 CSA C22.2 Frame size A 100 100 100 225 Number of poles Nr 1 3, 4 3, 4 3, 4 Rated voltage AC (50-60 Hz) V 277 600Y / 347V 480
More informationSentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More information3RV Motor Starter Protectors up to 100 A
General data Overview S0 motor 3RV1 motor are compact, current limiting motor which are optimized for load feeders. The motor are used for switching and protecting three-phase induction motors of up to
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More informationCUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH 3215-30 098793_0_000
Seite 1 von 6 Certification Record CUSTOMER CLASS FILE ABB STOTZ-KONTAKT GmbH 3215-30 098793_0_000 Eppelheimer Strasse 82, SUPPLEMENTARY PROTECTORS- COMPONENT ACCEPTANCE PROGRAM Heidelberg Baden-Wurttemberg
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationProtection Equipment
Protection Equipment Price groups 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 4N1 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors/ circuit breakers up to
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationTmax. Molded case circuit breakers. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com. Tmax.
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More information3K Load-Break Switches The Program for Safety and Performance. sentric
3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationMOTOR PROTECTIVE DEVICES
W MOTOR PROTECTIVE DEVICE, SERIES MP 206 BE400206 BE400306 Inherently stable without back-up fuseup to 4 A at 400 V AC, > 4 A main back-up fuse 100 A gl Thermal and magnetic release Terminal and accessory
More informationBreakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM
Breakers and Switches Switches Switch-disconnectors OT, OETL, OTDC and OTM Switch-disconnectors OT 16...2500, OETL 3150, OTDC16...32 and OTM160...2500 Contents 4 Product overview, features 8 Technical
More informationSafety detection solutions
Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking
More informationBETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
More informationMolded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data
Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationDimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)
9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity
More informationMotor circuit-breakers
Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationW DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6
W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions
More informationAC1645. System pro M compact Supplementary Protectors Miniature MCCBs
AC1645 System pro M compact Supplementary Protectors Miniature MCCBs Table of Content 1 2 3 4 5 pro M compact General information...1.1 S200 - Supplementary protectors...1.7 S200U - Miniature MCCBs...1.12
More informationApplication Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)
Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic
More informationCam Switches, Manual Motor Controllers, Disconnects For Single phase Applications
7/ Moeller Electric Corporation Manual Motor Controllers, Disconnects For use as Padlockable, red handle with yellow collar, suitable as Emergency-Stop Circuit function diagram Front Plate No. ) ON OFF
More informationCircuit Breakers Supplementary Protectors Manual Motor Controllers
WHITE PAPER Circuit Breakers Supplementary Protectors Manual Motor Controllers Circuit Protection Methods Differentiating between Supplementary Protection, Branch Circuit Protection, and Self-Protected
More informationMolded case circuit breakers
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationRotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationLow Voltage Fuses For Motor Protection
Code Requirements The NEC or CEC requires that motor branch circuits be protected against overloads and short circuits. Overload protection may be provided by fuses, overload relays or motor thermal protectors.
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationIndex. 15 - Miniature circuit breakers. Miniature circuit breakers. S200 Miniature circuit breakers...15.1-15.42
Miniature Index Miniature circuit breakers - Miniature Miniature... -.42 UL 489 Series Ordering details Description... Features... U-K, 240 VAC...2 U-Z, 240 VAC...3 UP-K, 480Y/277 VAC...4 UP-Z, 480Y/277
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
More informationBreakers and Switches. Switches Change-over, bypass and transfer switches
Breakers and Switches Switches Change-over, bypass and transfer switches Change-over, bypass and transfer switches Product overview, features Product overview 4 Features 6 Technical data Manual / motorized
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More informationSPEEDFAX TM 2011 Disconnect Switches Contents
SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection
More informationResidual Current Protective Devices
Residual Current Protective Devices /2 Introduction / 5SM3 RCCBs /9 SIQUENCE, 5SM3 and 5SU1 universal -sensitive RCCBs, type B and type B+ /12 Additional components /1 5SM2 RC units /18 5SU1 RCBOs /25
More informationPhone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationSENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationSwitching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches
Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation
More informationProduct Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage
More informationSoftstarters Type PSR
Catalog Softstarters Softstarters ABB Softstarters General To the left: A combination with PSR and a manual Motor Starter MS116 Above: PSR16, PSR30 and PSR 45 1 ABB Automation Products serve customers
More informationProduct Guide. Cable-in / cable-out miniature circuit breakers and supplementary protectors
Product Guide Cable-in / cable-out miniature circuit breakers and supplementary protectors Cable-in / cable-out miniature circuit breakers and supplementary protectors Eaton offers a complete line of
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More informationProduct Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
More informationCam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5
Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock
More informationHow To Protect A Motor From Overcurrent
Phase ailure elays Type PS and PD Class 8430 Catalog 04 CONTENTS Description.....................................................Page Product Description and Definitions......................................
More informationRenewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.
G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable
More informationVL circuit breakers. Information guide. www.usa.siemens.com/circuitbreakers
VL circuit breakers Information guide www.usa.siemens.com/circuitbreakers Table of contents Technical data 2 8 DG 150A frame 9 14 FG 250A frame 15 20 JG 400A frame 21 26 LG 600A frame 27 32 MG 800A frame
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationmecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationMaximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
More informationShort-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A
Short-circuit current rating (SCCR) of industrial control panels NEC Article 409 and UL 508A Short-circuit current rating (SCCR) of industrial control panels 1 Introduction 2 Overview of NEC Article 409
More informationVLT Series 3500 Adjustable Frequency Drive Instruction Manual
Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software
More informationLINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationMiniature Circuit Breakers and Supplementary Protectors
Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors. Industrial Circuit Breakers QUICKLAG............................................. QUICKLAG
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationELFA MINIATURE CIRCUIT BREAKERS
ELFA MINIATURE CIRCUIT BREAKERS Standard Accesories CATALOG NO. ITEM LIST M ELFA-714 3 Phase Bus connection $101.00 39 inches (1000 mm) M ELFA-085 Protective Cap for Finger Safe $ 1.70 M ELFA-760 Bus Bar
More informationSIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
More informationHow can a charging station for electric vehicles be set up simply and safely?
SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,
More informationProduct Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930
Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930 Description Firetrol FTA1930 Digital Solid State Starting Fire Pump Controllers feature soft start, soft stop and
More informationGuidelines on the Short Circuit Current Rating for Industrial Control Panels
usa.siemens.com/sccr Guidelines on the Short Circuit Current Rating for Industrial Control Panels Technical Paper for Practical Applications White Paper I October 2014 As per NEC Edition 2014, and UL508A
More informationOperation and Maintenance manual. fusible shunt trip switch
Operation and Maintenance manual fusible shunt trip switch Table of Contents Fusible Shunt Trip Switch Device Overview... 2 Installation Instructions... 3 Catalog Number Selection Table... 4 Motor Fuse
More informationUncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA
Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA Miniature Circuit Breaker SU 200 M The next generation MCB for UL/CSA applications within
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationHS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.
y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock
More informationSpeed Control Relays SX2
SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationZS25 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD
More informationACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
More informationBolted contact switches. Pringle switches
Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial
More informationHeavy Duty Control. Catalog Numbering System. General 8/47. Siemens Industry, Inc. Industrial Controls Catalog. 48 Overload Size
Heavy Duty Control Catalog Numbering System 48 Overload Size A B Frame A Frame B T ESP200 3 3 Phase Single Phase 00,, 20 or 30 Selectable Current Range A 0.2 B 0.7 3.4 Reset C 3 2 D. 22 E 40 F 3 2 G 2