1 FT-NIR SPECTROSCOPY application note Near-Infrared Spectroscopy in the Quality Control Laboratory of a Pharmaceutical Company An evaluation of a new technique for identification of raw materials and blinded study materials Dr. Peter Hofstetter of Werthenstein Chemie AG Dr. Joachim Oelichmann of PerkinElmer Instruments Introduction In the pharmaceutical industry, checking the identity and conformity of materials is one of the main tasks of the analytical lab. Nearinfrared spectroscopy is gaining importance as a tool for compound identification because it is fast, simple to use, and requires little or no sample preparation. Identification tests are mainly performed for: Raw Materials Biotech Operation, Chemical Pilot Plant, and Clinical Manufacturing. Clinical Study Material Identification of blinded study material for correct packaging according to treatment groups of the Master code i.e. active, placebo, and competitor s products). Accurate identification of compounds using NIR spectroscopy The near-infrared region had not traditionally been used analytically because complex molecule vibrations and overtones are abserved. This can lead to spectra that are not simple to predict or understand. From a NIR spectrum, the molecular structure cannot be predicted, however, each compound does have a unique NIR spectrum. A compound can be identified by comparing the sample spectrum with a reference spectrum. The main advantage of using NIR rather than conventional IR spectroscopy is, that undiluted samples can be measured directly. The instrument s reflection mode allows compounds to be identified - even through the outer package (e.g. a sample in a glass bottle, a capsule in a blister pack). Figure 1 shows such a simple measurement of a powder sample in a glass vial. The measurement takes only a few seconds with automatic data handling. Various compounds with small spectral differences can be confidently identified with the system s built-in chemometrics SIMCA software. Figure 1: Powder sample being placed on the Spectrum One (NTS), near infrared testing system, featuring the NIRA sampling module
2 The analytical laboratory is under pressure to perform more tests European GMP guidelines require that each container of a raw material be identified: "There should be appropriate procedures or measures to assure the identity of the contents of each container of starting material" (EU cgmp guidelines, chapter 5.30). This results in a substantial amount of work for the Biotech operation because raw materials are often delivered in several small units or containers. Additionally the number of clinical studies has drastically increased resulting in an increase in requests for materials identification. Figure 2 show a statistical analysis of the number of identification requests between 1983 and 1996 where each request consists of several identification checks. Assuring the identity of incoming raw materials Raw material identification by NIR is performed by comparing the sample s spectrum with a database containing reference spectra of all previously identified raw materials. The system performs a spectral comparison (COMPARE Function) and ranks the findings by similarity; from 1.0 or completely identical, to 0.0 or completely different. Lactose is a good example of how NIR can accurately compare the NIR spectra of very similar compounds. Lactose is used as formulation ingredient in both the hydrous and anhydrous forms. The NIR spectra of the two compounds can easily be distinguished because the hydrate form shows the -OH overtone vibrations. The NIR spectra of four batches of hydrous lactose and four batches of anhydrous lactose is shown in Figure 3. Figure 2: Analytical requests are on the rise at the pharmaceutical laboratory. Figure 3: NIR comparison of hydrous and anhydrous lactose.
3 Figure 4 is another example of using NIR to distinguish between polyethylene glycol compounds with different chain lengths and molecular weights. The sample materials were kept in brown glass bottles, and no preparation was performed before testing. The measurements were taken by placing a few ml of sample into a cup and scanning in transflectance mode using the system s reflectance sampling system. As a last example we have compared the NIR spectra of SCH dihydrochloride with that of SCH dihydrochloride dihydrate. Also in this example the two forms can easily be distinguished by NIR (Figure 5). Verifying a sample tablet s content simplifying this critical process for clinical studies Packaging double blind clinical study material is a critical step as all medications (active, placebo, and competitors products) look identical. Great care must be taken in order to prevent the mix-up of the products. As a final check, samples from one patient unit of each medication group are checked by quality control for identity. HPLC is the currently used to perform this verification. The HPLC method requires that the content of several samples (capsules) are dissolved in an appropriate solvent. A standard solution is prepared with a reference standard. A HPLC unit is set up, equilibrated for the methods, a system suitability check performed. Only then can the samples be analyzed. Thousands of units are measured this way by the QC lab. A simpler method would drastically reduce the efforts for these determinations. Figure 4: Using NIR to distinguish between polyethylene glycol compounds. Figure 5: Using NIR to distinguish between dihydrochloride and dihydrochloride dihydrate of an active
4 Figure 6: Identification of Ribavirin 200 mg capsule versus a placebo capsule Figure 7: Differentiation of Mometasone active powder from placebo powder NIR is an alternate technique that simplifies the sampling and method development process. The pharmaceutical sample is placed on the sample window and measured. Since NIR radiation penetrates the product a few millimeters before it s reflected, the compound within a capsule shell can be identified without opening the shell. In the case of the identification of an active capsule from a placebo capsule the spectrum of the active capsule is the sum of the spectra of the gelatin capsule and its content (excipients and active drug), while the spectrum of the placebo capsule is the sum of the spectra of the gelatin capsule and excipients without active drug. Small spectral differences can easily be distinguished by this method. The Spectrum One NTS built in chemometrics SIMCA software allows it to make a statistically significant assignment of a sample spectrum of the active or placebo group. An example of using NIR in this manner is the identification of Ribavirin 200 mg capsule versus a placebo capsule. The spectrum of the active capsule and the placebo capsule are significantly different (Figure 6). Another example is the identification of the content of Mometasone dry powder inhalers. In this case some powder was removed from the inhaler by opening the inhaler and placing it on a small glass plate for measuring. All different strengths of Mometasone inhalers contain the same powder, only the dosing device has a different volume. Differentiation of active powder from placebo powder is not simple, but there is a typical absorbance band in the active powder at 6120 cm -1, which is missing in the placebo powder (Figure 7).
5 Using chemometrics software (SIMCA) the spectra of active and placebo powder are reduced each to a datapoint in a x,y coordinate system. The system is calibrated by measuring 5 to 10 active and placebo capsules. The x,y coordinates of the datapoints of one medication group (active or placebo) should then lay within a certain range, with no overlapping of the ranges between active and placebo. The more different the spectra of active and placebo are, the bigger is the distance between the datapoints in the x,y coordinate system. Figure 8 shows this graphically for the case of the Mometasone DPI s. When a sample to be identified is measured, the spectral data are reduced in the same way to a x,y coordinate and the sample gets assigned to one of these groups, or its identification is not confirmed, if the x,y coordinates are outside of a certain range of the two groups. The report in Figure 9 shows such an assignment. We have measured randomly about 20 samples and each of them has been correctly identified. This example shows the limits of such a system. Only a NIR instrument with good resolution can distinguish small spectral differences. The other NIR instrument tested was not able to measure such small spectral differences as that instrument uses a spectral resolution of 25 cm-1 (compared to the instrument from PerkinElmer, which can be configured to a resolution of 2 cm-1). We also learned that this method is not applicable, when the active component in the medication unit is less than about 5% of the total unit weight, as in that case the spectral differences between active and placebo samples are too small. This is for example true for all biotechnological products and most of the solutions. Figure 8: The application of chemometrics software determines the clusters of the active and the placebo powders Figure 9: Classification report for the identification of Mometasone active powder
6 Approval of NIR as an accepted method by the health authorities NIR finds more and more applications in a GMP environment. It is often used in pharmaceutical companies for compound identification. The new issue of the European Pharmacopeia even has a separate chapter describing this technique. This technique is now a widely accepted method accepted by IKS and the Swiss Health Authorities. Demonstrating system performance and suitability are also important aspects of gaining regulatory approval. The NIR instrument has a built in calibration program, which calibrates the wavelength and transmission within a few minutes with a built in reference. A corresponding report is printed out. Compared to many other instruments this calibration is fast and very simple. It is recommended to perform this task about every six months. Conclusion After the tests all participants were surprised, how universal such an instrument can be used. The time reduction for raw material or study material identification is very significant as no sample preparation has to be performed and the measurement and reporting is performed within one to two minutes. Such an instrument could heavily reduce the workload in the lab. Get more connected. PerkinElmer Instruments 761 Main Avenue Norwalk, CT USA Tel: or (+1) Fax: (+1) U.K., PerkinElmer Infrared Spectroscopy Business PerkinElmer is a trademark of PerkinElmer, Inc. Spectrum One is a trademark of PerkinElmer Instruments LLC. Post Office Lane, Beaconsfield, Bucks, HP9 1QA Tel: (01494) Fax: (01494) / PerkinElmer, Inc. Printed in U.S.A. D-6283 KG030005
Pharmaceutical Quality Systems: US Perspective
Pharmaceutical Quality Systems: US Perspective Rick Friedman Associate Director, Office of Manufacturing and Product Quality Center for Drug Evaluation and Research Topics Background: The ICH Q10 Pharmaceutical
More informationQualitative NIR Analysis for Ingredients in the Baking Industry
Overview The challenge to all baking companies in today s economy is to operate plants as efficiently as possible, with a focus on quality and keeping costs in check. With regulatory issues becoming more
More informationIndustrial Process Monitoring Requires Rugged AOTF Tools
Industrial Process Monitoring Requires Rugged AOTF Tools Dr Jolanta Soos Growth has been rapid in the use of spectroscopic methods to monitor industrial processes, both in production lines and for quality
More informationBack to Basics Fundamentals of Polymer Analysis
Back to Basics Fundamentals of Polymer Analysis Using Infrared & Raman Spectroscopy Molecular Spectroscopy in the Polymer Manufacturing Process Process NIR NIR Production Receiving Shipping QC R&D Routine
More informationChemometric Analysis for Spectroscopy
Chemometric Analysis for Spectroscopy Bridging the Gap between the State and Measurement of a Chemical System by Dongsheng Bu, PhD, Principal Scientist, CAMO Software Inc. Chemometrics is the use of mathematical
More informationAnnex 7 Guidelines on pre-approval inspections
World Health Organization WHO Technical Report Series, No. 902, 2002 Annex 7 Guidelines on pre-approval inspections 1. General 94 2. Glossary 94 3. Objectives 95 4. Priorities 96 5. Preparation for the
More informationMeasurement & Analytics Measurement made easy. MB3600-CH10 FT-NIR oleochemicals analyzer Pre-calibrated for Iodine Value (IV) and %Trans Fat
Measurement & Analytics Measurement made easy MB36-CH1 FT-NIR oleochemicals analyzer Pre-calibrated for Iodine Value (IV) and %Trans Fat FT-NIR optimizing productivity Rapid, reliable oil and fat analysis
More informationMB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC
Measurement & Analytics Measurement made easy MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC MB3600 FT-NIR spectrometer for your industry
More informationINFRARED SPECTROSCOPY (IR)
INFRARED SPECTROSCOPY (IR) Theory and Interpretation of IR spectra ASSIGNED READINGS Introduction to technique 25 (p. 833-834 in lab textbook) Uses of the Infrared Spectrum (p. 847-853) Look over pages
More informationSpectrum 10 Spectroscopy Software
P R O D U C T N O T E Infrared Spectroscopy Spectrum 10 Spectroscopy Software PerkinElmer Spectrum 10 is the infrared spectroscopy software platform for the range of PerkinElmer FT-IR spectrometers. Designed
More informationIn this column installment, we present results of tablet. Raman Microscopy for Detecting Counterfeit Drugs A Study of the Tablets Versus the Packaging
Electronically reprinted from June 214 Molecular Spectroscopy Workbench Raman Microscopy for Detecting Counterfeit Drugs A Study of the Tablets Versus the Packaging With the increasing proliferation of
More informationGuideline on Process Validation
1 2 3 4 29 March 2012 EMA/CHMP/CVMP/QWP/70278/2012-Rev1 Committee for Medicinal Products for Human Use (CHMP) Committee for Medicinal Products for Veterinary Use (CVMP) 5 6 Draft Draft Agreed by CHMP /
More informationThe identification of tablets and capsules containing barbiturates by MATR infrared spectroscopy
J. Pharm. Pharmac., 1971,23,781-785 Recehled February 23, 1971 The identification of tablets and capsules containing barbiturates by MATR infrared spectroscopy J. E. ATKINSON The School of Pharmacy, Robert
More informationMeasurement & Analytics Measurement made easy
Measurement & Analytics Measurement made easy MB3600-PH Versatile FT-NIR analyzer for the life sciences and pharmaceutical industries Designed for QA/QC, research and development and at-line PAT applications
More informationQUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.
QUANTITATIVE INFRARED SPECTROSCOPY Objective: The objectives of this experiment are: (1) to learn proper sample handling procedures for acquiring infrared spectra. (2) to determine the percentage composition
More informationFT-NIR for Online Analysis in Polyol Production
Application Note: 51594 FT-NIR for Online Analysis in Polyol Production Key Words Acid Number Ethylene Oxide FT-NIR Hydroxyl Value Polyester Polyols Abstract Hydroxyl value and other related parameters
More informationANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION
Chem 306 Section (Circle) M Tu W Th Name Partners Date ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION Materials: prepared acetylsalicylic acid (aspirin), stockroom samples
More informationMeriCal Quality Profile
January 5, 2015 Dear Valued Customer, Since the implementation of new federal regulations, MeriCal Inc. has received a large volume of questionnaires and surveys regarding our services and procedures.
More informationWhy System Suitability Tests Are Not a Substitute for Analytical Instrument Qualification
White paper System Suitability Tests and AIQ R.D.McDowall PhD Principal, McDowall Consulting Paul Smith European Validation Program Manager, PerkinElmer Nicola Vosloo PhD European Market Development Leader,
More informationPHARMACEUTICAL REFERENCE STANDARDS
PHARMACEUTICAL REFERENCE STANDARDS 11 th International Symposium organised by the European Directorate for the Quality of Medicines & HealthCare (EDQM), Council of Europe 3-4 September 2012, Strasbourg,
More informationMultivariate Chemometric and Statistic Software Role in Process Analytical Technology
Multivariate Chemometric and Statistic Software Role in Process Analytical Technology Camo Software Inc For IFPAC 2007 By Dongsheng Bu and Andrew Chu PAT Definition A system Understand the Process Design
More informationImplementing New USP Chapters for Analytical Method Validation
Implementing New USP Chapters for Analytical Method Validation March 2010 Ludwig Huber Fax.: +49 7243 602 501 E-mail: Ludwig_Huber@labcompliance.com Today s Agenda Handling Method Changes vs. Adjustments
More informationPL 17871/0208 UKPAR TABLE OF CONTENTS
Fultium-D 3 3,200 IU Capsules PL 17871/0208 UKPAR TABLE OF CONTENTS Lay Summary Page 2 Scientific discussion Page 4 Steps taken for assessment Page 11 Summary of Product Characteristics Page 12 Patient
More informationSymmetric Stretch: allows molecule to move through space
BACKGROUND INFORMATION Infrared Spectroscopy Before introducing the subject of IR spectroscopy, we must first review some aspects of the electromagnetic spectrum. The electromagnetic spectrum is composed
More informationApplications of Near Infrared Spectroscopic Analysis in the Food Industry and. Research
Applications of Near Infrared Spectroscopic Analysis in the Food Industry and Research Written by Rolf Nilsson for the Food Safety Centre, Tasmanian Institute of Agricultural Research, University of Tasmania,
More informationBRIEFING 661.2 Plastic Packaging Systems for Pharmaceutical Use.
BRIEFING 661.2 Plastic Packaging Systems for Pharmaceutical Use. USP proposes the revision and development of a suite of plastic packaging system standards in the current issue of PF. General test chapter
More informationB i o s o l u t i o n s
B i o s o l u t i o n s Implementation of pharmatracker TM : A case study Prepared by Ocimum Biosolutions Ocimumbio Solutions August 2006 All rights reserved. 2 B i o s o l u t i o n s an ISO 9001:2000
More informationMicrobiology and Auditing. Don Singer
Microbiology and Auditing Don Singer ASQ Northeast Pharmaceutical GMP/Quality Conference 2011 Through the eyes of a Microbiologist Microbiology Audit = Inspection / Investigation Systematic Auditing Planning
More informationUltraviolet Spectroscopy
Ultraviolet Spectroscopy The wavelength of UV and visible light are substantially shorter than the wavelength of infrared radiation. The UV spectrum ranges from 100 to 400 nm. A UV-Vis spectrophotometer
More informationHandheld Raman Instruments for Pharmaceutical Raw Material Inspection: From the Lab to the Loading Dock
White Paper: 1.5 Handheld Raman Instruments for Pharmaceutical Raw Material Inspection: From the Lab to the Loading Dock Key Words Raw Material Identification Raman Spectroscopy Regulatory Compliance The
More informationAbsorption by atmospheric gases in the IR, visible and UV spectral regions.
Lecture 6. Absorption by atmospheric gases in the IR, visible and UV spectral regions. Objectives: 1. Gaseous absorption in thermal IR. 2. Gaseous absorption in the visible and near infrared. 3. Gaseous
More informationExtemporaneously Prepared Early Phase Clinical Trial Materials
Extemporaneously Prepared Early Phase Clinical Trial Materials Richard Hoffman, MS, RAC Eli Lilly & Co. Regulatory Advisor International Consortium for Innovation & Quality in Pharmaceutical Development
More informationIntroduction to Fourier Transform Infrared Spectrometry
Introduction to Fourier Transform Infrared Spectrometry What is FT-IR? I N T R O D U C T I O N FT-IR stands for Fourier Transform InfraRed, the preferred method of infrared spectroscopy. In infrared spectroscopy,
More informationANEXO VI. Near infrared transflectance spectroscopy. Determination of dexketoprofen in a hydrogel. M. Blanco y M. A. Romero
ANEXO VI Near infrared transflectance spectroscopy. Determination of dexketoprofen in a hydrogel M. Blanco y M. A. Romero Enviado para su publicación NEAR INFRARED TRANSFLECTANCE SPECTROSCOPY. Determination
More informationHPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies
HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies Application Note Small Molecule Pharmaceuticals Authors Jignesh Shah, Tiantian Li, and Anil Sharma Agilent Technologies,
More informationAsian Journal of Food and Agro-Industry ISSN 1906-3040 Available online at www.ajofai.info
As. J. Food Ag-Ind. 008, (0), - Asian Journal of Food and Agro-Industry ISSN 906-00 Available online at www.ajofai.info Research Article Analysis of NIR spectral reflectance linearization and gradient
More informationTotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow
TotalChrom Chromatography Data Systems Streamlining your laboratory workflow maximize productivity with TotalChrom CDS Acquiring, processing, reporting, reviewing and approving data is a streamlined series
More informationCombination Products. Presented by: Karen S. Ginsbury For: IFF March 2014. PCI Pharma
Combination Products Presented by: Karen S. Ginsbury For: IFF March 2014 Types of products Biological and medical device (freeze dried + syringe dual volume) Medical device and plasma devised product (syringe)
More informationPotential use of handheld Raman devices as tools for screening medicines for quality
Potential use of handheld Raman devices as tools for screening medicines for quality Mustapha Hajjou Program Manager U.S Pharmacopeia Convention Patrick Lukulay Vice President United States Pharmacopia
More informationBiotechpharma company profile
Biotechpharma company profile October 2013 1 History 2004 Biotechpharma UAB established as a proteomic research company in Vilnius, Lithuania 2005 Company became a member of UK s Northway group, investing
More informationNevirapine 200 mg tablets WHOPAR part 5 09/2010, version 1.0 (Matrix Laboratories Ltd), HA396 LABELLING. Page 1 of 8
LABELLING Page 1 of 8 PARTICULARS TO APPEAR ON THE OUTER PACKAGING OR, WHERE THERE IS NO OUTER PACKAGING, ON THE IMMEDIATE PACKAGING HDPE bottle carton label 1. NAME OF THE MEDICINAL PRODUCT Nevirapine
More informationIR Applied to Isomer Analysis
DiscovIR-LC TM Application Note 025 April 2008 Deposition and Detection System IR Applied to Isomer Analysis Infrared spectra provide valuable information about local configurations of atoms in molecules.
More informationO2PLS for improved analysis and visualization of complex data
O2PLS for improved analysis and visualization of complex data Lennart Eriksson 1, Svante Wold 2 and Johan Trygg 3 1 Umetrics AB, POB 7960, SE-907 19 Umeå, Sweden, lennart.eriksson@umetrics.com 2 Umetrics
More informationDetermining the Structure of an Organic Compound
Determining the Structure of an Organic Compound The analysis of the outcome of a reaction requires that we know the full structure of the products as well as the reactants In the 19 th and early 20 th
More informationGetting Answers at the Source Requires a New Way of Thinking About Software
m o l e c u l a r s p e c t r o s c o p y RESULT Software Getting Answers at the Source Requires a New Way of Thinking About Software Method Development Workflow Development Deployment & Support Methodology
More informationC 5. chemical development contract research custom synthesis cgmp API manufacturing commercial production. Welcome to
C 5 chemical development contract research custom synthesis cgmp API manufacturing commercial production Welcome to ChemCon Company profile Company profile ChemCon offers outstanding chemical services
More informationUrostemol Men capsules THR 02855/0240
Urostemol Men capsules THR 02855/0240 UKPAR TABLE OF CONTENTS Lay summary Page 2 Scientific discussion Page 3 Steps taken for assessment Page 14 Steps taken after initial registration Page 15 Summary of
More information0 10 20 30 40 50 60 70 m/z
Mass spectrum for the ionization of acetone MS of Acetone + Relative Abundance CH 3 H 3 C O + M 15 (loss of methyl) + O H 3 C CH 3 43 58 0 10 20 30 40 50 60 70 m/z It is difficult to identify the ions
More informationSPECIFICATIONS AND CONTROL TESTS ON THE FINISHED PRODUCT
SPECIFICATIONS AND CONTROL TESTS ON THE FINISHED PRODUCT Guideline Title Specifications and Control Tests on the Finished Product Legislative basis Directive 75/318/EEC as amended Date of first adoption
More informationThe photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
More informationAMBERLITE IRP64 Pharmaceutical Grade Cation Exchange Resin (Polacrilex Resin)
AMBERLITE IRP64 Pharmaceutical Grade Cation Exchange Resin (Polacrilex Resin) Description AMBERLITE IRP64 [1] resin is an insoluble, weakly acidic, hydrogen form, cation exchange resin supplied as a dry,
More informationHighly Potent APIs The right platform, people and procedures for successful development and manufacturing
Pharma&Biotech Highly Potent APIs The right platform, people and procedures for successful development and manufacturing Custom Manufacturing and Development Services for Highly Potent APIs Pharma&Biotech
More informationSTABILITY TESTING: PHOTOSTABILITY TESTING OF NEW DRUG SUBSTANCES AND PRODUCTS
INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED TRIPARTITE GUIDELINE STABILITY TESTING: PHOTOSTABILITY TESTING OF NEW
More informationMeasuring equipment in a laboratory.
Measuring equipment in a laboratory. Laboratory and metrology are two words that practically do not function separately. They are integrally connected to measuring equipment for tests and measurements.
More informationInfrared Spectroscopy: Theory
u Chapter 15 Infrared Spectroscopy: Theory An important tool of the organic chemist is Infrared Spectroscopy, or IR. IR spectra are acquired on a special instrument, called an IR spectrometer. IR is used
More informationProcess Validation Protocol (Reference: SOP )
Project Name Equipment Manufacturer Process Line/Location Project Number Serial Number Model Number Protocol number [Enter Product Title, Number & Strength] MULTI VITAMIN TABLETS PRODUCT CODE: Name: Position:
More informationIncreasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening
Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening Application Note Forensics Author Erin Shonsey Director of Research Alabama Department of Forensic Science Abstract
More informationwhere h = 6.62 10-34 J s
Electromagnetic Spectrum: Refer to Figure 12.1 Molecular Spectroscopy: Absorption of electromagnetic radiation: The absorptions and emissions of electromagnetic radiation are related molecular-level phenomena
More informationDETECTION OF COATINGS ON PAPER USING INFRA RED SPECTROSCOPY
DETECTION OF COATINGS ON PAPER USING INFRA RED SPECTROSCOPY Eduard Gilli 1,2 and Robert Schennach 1, 2 1 Graz University of Technology, 8010 Graz, Austria 2 CD-Laboratory for Surface Chemical and Physical
More informationFTIR Instrumentation
FTIR Instrumentation Adopted from the FTIR lab instruction by H.-N. Hsieh, New Jersey Institute of Technology: http://www-ec.njit.edu/~hsieh/ene669/ftir.html 1. IR Instrumentation Two types of instrumentation
More informationAn Industry White Paper
Driving Continuity and Collaboration from Lab Floor to Plant Floor to Top Floor An Industry White Paper Who is AspenTech? AspenTech is a global company founded in 1981 with more than 1,300 employees in
More informationInfrared Spectroscopy 紅 外 線 光 譜 儀
Infrared Spectroscopy 紅 外 線 光 譜 儀 Introduction Spectroscopy is an analytical technique which helps determine structure. It destroys little or no sample (nondestructive method). The amount of light absorbed
More informationACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND
#3. Acid - Base Titrations 27 EXPERIMENT 3. ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND Carbonate Equilibria In this experiment a solution of hydrochloric
More informationIMPURITIES IN NEW DRUG PRODUCTS
INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED TRIPARTITE GUIDELINE IMPURITIES IN NEW DRUG PRODUCTS Q3B(R2) Current
More information1. Scope This SOP covers requirements for PHARMCO-AAPER s Quality Management System
Page 1 of 8 1. Scope This SOP covers requirements for PHARMCO-AAPER s Quality Management System 2. Application This Standard Operating Procedure applied to the entire Quality Management System as it relevant
More informationChemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets
Chemistry 119: Experiment 7 Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets Vitamin C is another name for ascorbic acid (C 6 H 8 O 6, see below ), a weak acid that can be determined by titration
More informationMB3000-PH FT-IR spectrometer for the pharmaceutical industry Designed for QA/QC, formulation, research and development laboratory applications
Measurement & Analytics Measurement made easy MB3000-PH FT-IR spectrometer for the pharmaceutical industry Designed for QA/QC, formulation, research and development laboratory applications MB3000-PH FT-IR
More informationReflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.
T e c h n i c a l N o t e Reflectance Measurements of Materials Used in the Solar Industry UV/Vis/NIR Author: Dr. Jeffrey L. Taylor PerkinElmer, Inc. 710 Bridgeport Avenue Shelton, CT 06484 USA Selecting
More informationHomeland Security, Medical, Pharmaceutical and Non-destructive Testing Applications of Terahertz Radiation
Applications of THz Radiation APS March Meeting, March 23, 2005 Homeland Security, Medical, Pharmaceutical and Non-destructive Testing Applications of Terahertz Radiation Colin Baker colin.baker@teraview.com
More informationA Look at Accelerated Photostability Testing for Packaged Food and Drinks
A Look at Accelerated Photostability Testing for Packaged Food and Drinks By Dr. Oliver Rahäuser and Dr. Artur Schönlein Atlas Material Testing Technology GmbH Vogelsbergstr. 22, 63589 Linsengericht-Altenhaßlau,
More informationBilling with National Drug Codes (NDCs) Frequently Asked Questions
Billing with National Drug Codes (NDCs) Frequently Asked Questions NDC Overview Converting HCPCS/CPT Units to NDC Units Submitting NDCs on Professional/Ancillary Claims Reimbursement Details For More Information
More informationNear Infrared Transmission Spectroscopy in the Food Industry
Near Infrared Transmission Spectroscopy in the Food Industry Introduction: Near Infrared Spectroscopy is used in many industries including the pharmaceutical, petrochemical, agriculture, cosmetics, chemical
More informationINTRODUCING THE NEW. Xcelodose S. New Powder Micro-dosing System. Even Faster Time to First in Man
INTRODUCING THE NEW Xcelodose S New Powder Micro-dosing System Even Faster Time to First in Man Xcelodose S Benefits Even Faster Time to First in Man with precision, speed and accuracy Fills with precision
More informationValidation and Calibration. Definitions and Terminology
Validation and Calibration Definitions and Terminology ACCEPTANCE CRITERIA: The specifications and acceptance/rejection criteria, such as acceptable quality level and unacceptable quality level, with an
More informationIR READY TOGO. Spectrum Two FT-IR Spectroscopy
IR READY TOGO Spectrum Two FT-IR Spectroscopy 2 IR FOR EVERYBODY EVERYWHERE EVERYDAY SPECTRUM TWO IR READY TO GO Easy to use, powerful, compact and robust Spectrum Two is the IR spectrometer of choice
More informationPublic Assessment Report. Decentralised Procedure
Public Assessment Report Decentralised Procedure Olopatadine Zentiva 1 mg/ml eye drops, solution (olopatadine hydrochloride) Procedure No: UK Licence No: PL 17780/0568 Winthrop Pharmaceuticals UK Limited
More informationPublic Assessment Report Scientific discussion. Prednisolon Alternova (previous Prednisolon E Consult) (prednisolone) Asp no: 2011-0921
Public Assessment Report Scientific discussion Prednisolon Alternova (previous Prednisolon E Consult) (prednisolone) Asp no: 2011-0921 This module reflects the scientific discussion for the approval of
More informationMultivariate Tools for Modern Pharmaceutical Control FDA Perspective
Multivariate Tools for Modern Pharmaceutical Control FDA Perspective IFPAC Annual Meeting 22 January 2013 Christine M. V. Moore, Ph.D. Acting Director ONDQA/CDER/FDA Outline Introduction to Multivariate
More informationThe Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD
TN-100 The Fundamentals of Infrared Spectroscopy The Principles of Infrared Spectroscopy Joe Van Gompel, PhD Spectroscopy is the study of the interaction of electromagnetic radiation with matter. The electromagnetic
More informationNEW CHEMICAL ENTITIES
NEW CHEMICAL ENTITIES PIONEERING PARTNER FOR PEPTIDES With more than 40 years of expertise in peptide synthesis, a track record in process development, large-scale manufacturing and outstanding product
More informationAppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT
AppNote 6/2003 Analysis of Flavors using a Mass Spectral Based Chemical Sensor Vanessa R. Kinton Gerstel, Inc., 701 Digital Drive, Suite J, Linthicum, MD 21090, USA Kevin L. Goodner USDA, Citrus & Subtropical
More informationAPPLIED. Measuring Caffeine Concentration. Application Summary. Analytes: caffeine (C 8 H 10 N 4 O 2
Application Summary Analytes: caffeine (C 8 H 10 N 4 O 2 ) Detector: OMA-300 Process Analyzer (UV-Vis spectrophotometer) Introduction While it may mystify those of us that need strong coffee to get through
More informationGMP Pharma BV. Netherlands
GMP Pharma BV Netherlands Connecting the European & Indian Pharmaceutical, Biotechnology and Biopharmaceutical Industry for parallel growth and solicitation. About Us: GMP Pharma BV is a multisource organization
More information2Technical Support 3Formulation Development 4Proof of Concept 5 GMP Services 6Advanced Drug Delivery 1EUDRAGIT Products Evonik. Power to create.
GMP Services Solutions for Clinical Sample Manufacturing 1 EUDRAGIT Products 2 Technical Support 3 Formulation Development Proof of Concept 4 5 GMP Services 6 Advanced Drug Delivery Evonik. Power to create.
More information13C NMR Spectroscopy
13 C NMR Spectroscopy Introduction Nuclear magnetic resonance spectroscopy (NMR) is the most powerful tool available for structural determination. A nucleus with an odd number of protons, an odd number
More informationLacidipine 2 mg Film-Coated Tablets PL 08553/0502. Lacidipine 4 mg Film-Coated Tablets PL 08553/0503. UK Public Assessment Report
Lacidipine 2 mg Film-Coated Tablets PL 08553/0502 Lacidipine 4 mg Film-Coated Tablets PL 08553/0503 UK Public Assessment Report TABLE OF CONTENTS Lay Summary Page 2 Scientific discussion Page 4 Steps taken
More informationMozzarella Process Analysis Get more out of your production with High Resolution in-line analysis. ProFoss. Dedicated Analytical Solutions
Mozzarella Process Analysis Get more out of your production with High Resolution in-line analysis ProFoss Dedicated Analytical Solutions Get a clearer picture of your mozzarella production with High Resolution
More informationLean Process Improvements for the GMP Laboratory
Lean Process Improvements for the GMP Laboratory ITRODUCTIO Pharmaceutical manufacturing costs the industry approximately $90 billion each year and represents twice the expenditure of research and development.
More informationAnalysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )
Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 ) Andrew Aubin Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S Fast analysis of
More informationAustin Peay State University Department of Chemistry Chem 1111. The Use of the Spectrophotometer and Beer's Law
Purpose To become familiar with using a spectrophotometer and gain an understanding of Beer s law and it s relationship to solution concentration. Introduction Scientists use many methods to determine
More informationRaising the Bar in FT-IR: Getting the Most Out of On-site Oil Condition Monitoring
Technical Note Raising the Bar in FT-IR: Getting the Most Out of On-site Oil Condition Monitoring FT-IR Spectroscopy Introduction Lubrication is a vital component of machinery and, as with any component,
More informationSIMCA 14 MASTER YOUR DATA SIMCA THE STANDARD IN MULTIVARIATE DATA ANALYSIS
SIMCA 14 MASTER YOUR DATA SIMCA THE STANDARD IN MULTIVARIATE DATA ANALYSIS 02 Value From Data A NEW WORLD OF MASTERING DATA EXPLORE, ANALYZE AND INTERPRET Our world is increasingly dependent on data, and
More informationThe Effect of Coating Process Conditions and Coating Formula Type on the Quantity and Location of Water in Film Coated Tablets
OPADRY II Application Data High Performance Film Coating System The Effect of Coating Process Conditions and Coating Formula Type on the Quantity and Location of Water in Film Coated Tablets OBJECTIVES
More informationExperiment #5: Qualitative Absorption Spectroscopy
Experiment #5: Qualitative Absorption Spectroscopy One of the most important areas in the field of analytical chemistry is that of spectroscopy. In general terms, spectroscopy deals with the interactions
More informationAxION edoor. Web-Based, Open-Access Mass Spectrometry Software
AxION edoor Web-Based, Open-Access Mass Spectrometry Software 2 AxION edoor is the open-access software solution for today s fast-paced laboratory. It is designed to operate and optimize the management
More informationCatalog. Global Education. and Training. Global Expertise Trusted Standards Improved Health
Global Education Catalog 2013 2014 and Training Global Expertise Trusted Standards Improved Health USP s mission is to improve global health through public standards and related programs that help ensure
More informationA Complete Solution for Method Linearity in HPLC and UHPLC
Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,
More informationEvaluating Current Practices in Shelf Life Estimation
Definition of Evaluating Current Practices in Estimation PQRI Stability Working Group Pat Forenzo Novartis James Schwenke Applied Research Consultants, LLC From ICH Q1E An appropriate approach to retest
More informationGRADUATE CERTIFICATE IN GOOD MANUFACTURING PRACTICE (GMP) Plan your career for tomorrow and you will be ahead of your competitors
GRADUATE CERTIFICATE IN GOOD MANUFACTURING PRACTICE (GMP) Plan your career for tomorrow and you will be ahead of your competitors This course is a distance-learning program that will culminate in a Graduate
More informationANALYTICAL OUTSOURCING WHY SHOULD YOU OUTSOURCE?
ANALYTICAL OUTSOURCING WHY SHOULD YOU OUTSOURCE? The choice to outsource is a somewhat difficult decision, but it is one that can be both analytically and financially rewarding. By carefully considering
More information