VIESMANN. VITOCELL 340-M/360-M Heating water buffer cylinder with DHW heating 750 and 950 litre capacity. Datasheet. VITOCELL 360-M Type SVSA

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "VIESMANN. VITOCELL 340-M/360-M Heating water buffer cylinder with DHW heating 750 and 950 litre capacity. Datasheet. VITOCELL 360-M Type SVSA"

Transcription

1 VIESMANN VITOCELL 340-M/360-M Heating water buffer cylinder with DHW heating 750 and 950 litre capacity Datasheet Part numbers and prices: see pricelist VITOCELL 340-M Type SVKA Multi-mode heating water buffer cylinder with integral DHW heating Heating water: 708/906 l content DHW: 30/30 l capacity Indirect solar coil: 12/14 l content VITOCELL 360-M Type SVSA Multi-mode heating water buffer cylinder with stratification system and integral DHW heating Heating water: 708/906 l content DHW: 30/30 l capacity Indirect solar coil: 12/14 l content 5/2010

2 Product information Vitocell 340-M and Vitocell 360-M Connection of several heat sources and hygienic DHW heating with high draw-off rates; space-efficient in a single combi cylinder. Benefits at a glance Vitocell 340-M/360-M combination of heating water buffer cylinder and DHW cylinder. For heating systems with several heat sources. Particularly suitable in connection with Viessmann solar thermal systems for DHW heating and central heating backup. Connections at different heights enable the utilisation of different heat sources, e.g. a solid fuel boiler. The temperature stratification remains unaffected. Low space requirement and installation effort combined DHW cylinder and buffer cylinder. Corrugated DHW pipe made from high-alloy stainless steel resilient and stress-free integration in the cylinder. Optimum exploitation of solar energy through targeted cooling in the lower section via the large indirect coil surface of the corrugated DHW pipe. Vitocell 360-M: The stratification system provides layering of solar heated water at different temperatures, making DHW heated by solar energy available very quickly. Vitocell 340-M (type SVKA) multi-mode heating water buffer cylinder with integral DHW heating A Heating water flow 1 / air vent valve B DHW / DHW circulation C Corrugated DHW pipe made from stainless steel D Heating water flow 2 / heating water return 1 E EHE immersion heater F Heating water return 2 H Heating water return 3 K Cold water L Drain M Heating water return / solar thermal system drain N Heating water flow / solar thermal system air vent valve 2 VIESMANN VITOCELL 340-M/360-M

3 Benefits at a glance (cont.) C Corrugated DHW pipe made from stainless steel D Heating water flow 2 / heating water return 1 E EHE immersion heater F Heating water return 2 G Stratification system H Heating water return 3 K Cold water L Drain M Heating water return / solar thermal system drain N Heating water flow / solar thermal system air vent valve Vitocell 360-M (type SVSA) multi-mode heating water buffer cylinder with stratification system and integral DHW heating A Heating water flow 1 / air vent valve B DHW / DHW circulation VITOCELL 340-M/360-M VIESMANN 3

4 Specification Vitocell 340-M / Vitocell 360-M For storing heating water and heating DHW in conjunction with solar collectors, heat pumps and solid fuel boilers. Suitable for the following systems: DHW temperature up to 95 C Heating water flow temperature up to 110 C Solar flow temperature up to 140 C Operating pressure on the heating water side up to 3 bar Operating pressure on the solar side up to 10 bar Operating pressure on the DHW side up to 10 bar Cylinder capacity l Heating water content l DHW capacity l Indirect solar coil content l DIN register number Vitocell 340-M 0262/06-10MC/E Vitocell 360-M 0263/06-10MC/E Dimensions Length (7) incl. thermal insulation a mm excl. thermal insulation o mm Width b mm Height incl. thermal insulation c mm excl. thermal insulation mm Height when tilted excl. thermal insulation and adjustable feet mm Weight of Vitocell 340-M incl. thermal insulation kg excl. thermal insulation kg Weight of Vitocell 360-M incl. thermal insulation kg excl. thermal insulation kg Connections Heating water flow and return R 1¼ 1¼ Cold water, hot water R 1 1 Heating water flow and return (solar) G 1 1 Drain R 1¼ 1¼ Solar indirect coil Heating surface m Indirect DHW coil Heating surface m Max. connectable aperture area Vitosol m Standby heat loss q BS at 45 K temperature differential kwh/24 h (standard parameter) Standby capacity V aux l Solar capacity V sol l VIESMANN VITOCELL 340-M/360-M

5 Vitocell 340-M, type SVKA TH TH k g l i Specification Vitocell 340-M / Vitocell 360-M (cont.) HV1/EL WW/Z ELH TH SPR1 HV2/HR1 SPR2/TH c b o m HR2 SPR3/TH HR3 KW f e d a n n HVs/ELs E h HRs HVs/HRs/ELs ELH SPR1-3 E Drain EL Air vent valve EL s Solar indirect coil air vent valve ELH Immersion heater (fem. connection Rp 1½) HR Heating water return HR s Heating water return, solar thermal system HV Heating water flow HV s Heating water flow, solar thermal system KW Cold water TH Fitting for thermometer sensor or additional sensor SPR Temperature sensor or thermostat WW DHW Z DHW circulation (threaded DHW circulation fitting, accessory) Dimensions Cylinder capacity l Length (7) a mm Width b mm Height c mm d mm e mm f mm g mm h mm i mm k mm l mm m mm n mm Length excl. thermal insulation o mm VITOCELL 340-M/360-M VIESMANN 5

6 l i Specification Vitocell 340-M / Vitocell 360-M (cont.) Vitocell 360-M, type SVSA TH HV1/EL WW/Z ELH TH SPR1 HV2/HR1 SPR2/TH c b o HR2 e d HVs/ELs m n n g SPR3/TH HR3 KW f a E h k HRs TH HVs/HRs/ELs ELH SPR1-3 E EL EL s ELH HR HR s Drain Air vent valve Solar indirect coil air vent valve Immersion heater (fem. connection Rp 1½) Heating water return Heating water return, solar thermal system HV Heating water flow HV s Heating water flow, solar thermal system KW Cold water TH Fitting for thermometer sensor or additional sensor SPR Temperature sensor or thermostat WW DHW Z DHW circulation (threaded DHW circulation fitting, accessory) Dimensions Cylinder capacity l Length (7) a mm Width b mm Height c mm d mm e mm f mm g mm h mm i mm k mm l mm m mm n mm Length excl. thermal insulation o mm Continuous output Continuous output kw For DHW heating from 10 to 45 C and a heating water flow temperature of 70 C at the heating l/h water throughput stated below (tested at HV 1 /HR 1 ) Heating water throughput for the stated continuous output l/h Continuous output kw For DHW heating from 10 to 60 C and a heating water flow temperature of 70 C at the heating water throughput stated below (tested at HV 1 /HR 1 ) l/h Heating water throughput for the stated continuous output l/h Information regarding continuous output When designing the system for the continuous output as stated or calculated, allow for the corresponding circulation pump. The stated continuous output is only achieved when the rated boiler output continuous output. 6 VIESMANN VITOCELL 340-M/360-M

7 Specification Vitocell 340-M / Vitocell 360-M (cont.) Performance factor N L To DIN Cylinder storage temperature T cyl = cold water inlet temperature + 50 K +5 K/-0 K and 70 C heating water flow temperature. Performance factor N L subject to the heat input delivered by the boiler (Q D ) Cylinder capacity l Q D in kw N L performance factor Information regarding performance factor The performance factor N L varies according to the cylinder storage temperature T cyl. Standard values T cyl = 60 C 1.0 N L T cyl = 55 C 0.75 N L T cyl = 50 C 0.55 N L T cyl = 45 C 0.3 N L Peak output (over 10 minutes) Relative to the performance factor N L. DHW heating from 10 to 45 C and 70 C heating water flow temperature. Peak output (l/10 min) subject to the heat input delivered by the boiler (Q D ) Cylinder capacity l Q D in kw Peak output Max. draw-off rate (over 10 minutes) Relative to the performance factor N L. With reheating. DHW heating from 10 to 45 C and 70 C heating water flow temperature. Max. DHW draw-off rate (l/min) subject to the heat input delivered by the boiler (Q D ) Cylinder capacity l Q D in kw max. draw-off rate Available water volume Cylinder volume heated to 60 C. Without reheating. Draw-off rate l/min Available water volume Water with t = 45 C (mixed temperature) 750 l l VITOCELL 340-M/360-M VIESMANN 7

8 Specification Vitocell 340-M / Vitocell 360-M (cont.) Pressure drop Pressure drop in mbar Heating water throughput in l/h Pressure drop (on the heating water side) Pressure drop in mbar B A 2000 Process medium throughput in l/h Pressure drop on the solar side A Cylinder capacity 750 l B Cylinder capacity 950 l 8 VIESMANN VITOCELL 340-M/360-M

9 Specification Vitocell 340-M / Vitocell 360-M (cont.) Pressure drop in mbar DHW throughput in l/h 2000 Pressure drop on the DHW side 750/950 l Delivered condition Vitocell 340-M, type SVKA 750 and 950 litre capacity Multi-mode heating water buffer cylinder, made from steel with integral stainless steel indirect coil for DHW heating. 3 welded-in sensor wells 2 thermometers 2 fittings for additional thermometer sensors or additional sensors Adjustable threaded feet Air vent valve for the indirect solar coils Packed separately and fitted to the crate: Thermal insulation made from polyester fleece The colour of the plastic-coated thermal insulation is Vitosilver Vitocell 360-M, type SVSA 750 and 950 litre capacity Multi-mode heating water buffer cylinder, made from steel with stratification system and integral stainless steel indirect coil for DHW heating. 3 welded-in sensor wells 2 thermometers 2 fittings for additional thermometer sensors or additional sensors Adjustable threaded feet Air vent valve for the indirect solar coils Packed separately and fitted to the crate: Thermal insulation made from polyester fleece The colour of the plastic-coated thermal insulation is Vitosilver VITOCELL 340-M/360-M VIESMANN 9

10 Design information Vitocell 340-M / 360-M DHW connection Connection to DIN 1988 Vitocell 340-/360-M A DHW B DHW circulation line C DHW circulation pump D Spring-loaded check valve E Tundish F Safety valve G Shut-off valve H Flow regulating valve *1 (installation recommended) The safety valve must be installed. K Pressure gauge connector L Non-return valve M Drain N Cold water O Drinking water filter *2 P Pressure reducer to DIN issue Dec R Non-return valve/pipe separator S Diaphragm expansion vessel, suitable for drinking water Recommendation: Install the safety valve higher than the top edge of the cylinder. This protects the valve against contamination, scaling and high temperatures. The DHW cylinder must then not be drained when working on the safety valve. Heating water flow temperatures in excess of 110 C For these operating conditions, DIN 4753 recommends the installation of a type-tested high limit safety cut-out in the cylinder, which limits the temperature to 95 C. Warranty Our warranty for DHW cylinders requires that the water to be heated meets the potable water quality in accordance with current Drinking Water Ordinance, and that existing water treatment systems work correctly. Heat transfer surface The corrosion-resistant, protected heat transfer surface (DHW/process medium) corresponds to type C to DIN *1 We recommend the installation and adjustment of the maximum water flow rate in accordance with the 10-minute peak performance of the DHW cylinder. *2 According to DIN , a drinking water filter should be installed in systems with metal pipework. Viessmann and DIN 1988 also recommend the installation of a drinking water filter when using plastic pipes, to prevent contamination entering the DHW system. 10 VIESMANN VITOCELL 340-M/360-M

11 Design information Vitocell 340-M / 360-M (cont.) Immersion heater When using third party products, the threaded heater element must have an unheated length of at least 100 mm. Technical guide For further information regarding the design and sizing, see the "Vitosol technical guide" and the "Vitoligno technical guide". Installation example with Vitocell 340-M WW RL VL VL VL RL AB A M B RL RL RL KW KW Cold water D Solar control unit WW DHW E Solar collector RL Return F Collector temperature sensor VL Flow G Air vent valve *3 A Oil/gas boiler H Solar-Divicon (pump station) B Heating circuit K Fill valve C Vitocell 340-M L Manual solar fill pump *3 Install at least one air vent valve (quick-acting air vent valve with shut-off valve or a manual air vent valve) at the highest point of the system. VITOCELL 340-M/360-M VIESMANN 11

12 Design information Vitocell 340-M / 360-M (cont.) M Air separator *4 N Cylinder temperature sensor O P DHW circulation Draw-off points Vitocell 340-M / 360-M accessories Thermometer Part no To be installed in the thermal insulation for cylinders with 750 and 950 litre capacity. Note One or two thermometers can be installed to capture the temperature profile inside the cylinder (e.g. in conjunction with solid fuel boilers) EHE immersion heater Current type and rated voltage 3/N/PE 400 V/50 Hz IP rating: IP 54 Output range max. 6 kw max. 12 kw Rated power consumption in standard operation/during quick heat-up kw Rated current A Heat-up time from 10 to 60 C 750 l h l h Multi-mode heating water buffer cylinder with DHW heating and EHE immersion heater Vitocell 340-M 360-M Cylinder capacity (total) l Cylinder capacity/content (heating water/dhw/solar) l 708/30/12 906/30/14 708/30/12 906/30/14 Content to be heated with an immersion heater l Dimensions Width b (with EHE immersion heater) mm Minimum wall clearance for the installation of an 2/4/6 kw mm EHE immersion heater 4/8/12 kw mm Weight Vitocell 340-/360-M with thermal insulation kg EHE immersion heater 2/4/6 kw kg /8/12 kw kg b b Vitocell 340-M with EHE immersion heater Vitocell 360-M with EHE immersion heater b: Width incl. EHE immersion heater b: Width incl. EHE immersion heater *4 Mount the air separator at an accessible point in the flow pipe. 12 VIESMANN VITOCELL 340-M/360-M

13 Vitocell 340-M / 360-M accessories (cont.) Threaded DHW circulation fitting Part no For connecting a DHW circulation line to the DHW connection. WW WW Z WW DHW Z DHW circulation Circulation pump for cylinder heating Part no Pump type UP VIRS 30/6-1 VI TOP-S 40/4 Voltage V~ Power consumption W Connection R 1 1¼ DN 40 Connecting cable m for boilers up to 40 kw from 40 to 70 kw from 70 kw Part no and B A Part no Head in m 1 C Pump rate in m³/h A Part no B Part no C Part no VITOCELL 340-M/360-M VIESMANN 13

14 Vitocell 340-M / 360-M accessories (cont.) Safety assembly to DIN 1988 Safety assembly, comprising: Shut-off valve Non-return valve and test connector Pressure gauge connector Diaphragm safety valve DN 20/R 1 Maximum heat input 150 kw 10 bar: Part no VIESMANN VITOCELL 340-M/360-M

15 VITOCELL 340-M/360-M VIESMANN 15

16 Printed on environmentally friendly, chlorine-free bleached paper Subject to technical modifications. Viessmann Werke GmbH&Co KG D Allendorf Telephone: Fax: Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Telephone: Fax: VIESMANN VITOCELL 340-M/360-M

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy VIESMANN VITOSOL 200-F Flat-plate collector for the utilisation of solar energy Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 13 VITOSOL 200-F Type SV2 and SH2 Flat-plate

More information

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation) PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold

More information

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol

More information

VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy

VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy Datasheet Part no. and prices: see pricelist VITOSOL 200-F Type SV2A/B and SH2A/B Flat-plate collector for vertical or horizontal

More information

VIESMANN. VITODENS Gas condensing boiler 3.8 to 35.0 kw. Technical guide. VITODENS 200-W Type WB2C. VITODENS 222-W Type WS2B. VITODENS 300-W Type WB3D

VIESMANN. VITODENS Gas condensing boiler 3.8 to 35.0 kw. Technical guide. VITODENS 200-W Type WB2C. VITODENS 222-W Type WS2B. VITODENS 300-W Type WB3D VIESMNN VITODENS Gas condensing boiler 3.8 to 35.0 kw Technical guide VITODENS 200-W Type WB2C Wall mounted gas condensing boiler, 4.8 to 35.0 kw, for natural gas and LPG VITODENS 222-W Type WS2B Compact

More information

Technical Data Manual Model Nos. and pricing: see Price List

Technical Data Manual Model Nos. and pricing: see Price List VITOCELL-V 00 Indirect-fired domestic hot water storage tank 4 to 0 / 60 to Technical Data Manual Model Nos. and pricing: see Price List Vitocell-V 00 4 to / 60 to Vitocell-V 00 0 / Vitocell-V 00 CVA Series

More information

VIESMANN. VITODENS Gas condensing boiler 1.9 to 35.0 kw. Technical guide. VITODENS 200-W Type B2HA, B2KA. VITODENS 222-W Type B2LA

VIESMANN. VITODENS Gas condensing boiler 1.9 to 35.0 kw. Technical guide. VITODENS 200-W Type B2HA, B2KA. VITODENS 222-W Type B2LA VIESMANN VITODENS Gas condensing boiler 1.9 to 35.0 kw Technical guide VITODENS 200-W Type B2HA, B2KA Wall mounted gas condensing boiler 3.2 to 35.0 kw For natural gas and LPG VITODENS 222-W Type B2LA

More information

The Fusion Range of Electric Boilers

The Fusion Range of Electric Boilers The Fusion Range of Electric Boilers The Ultimate Solution for Electric Wet Central Heating Our range of Electric Boilers provide complete peace of mind for reliability, performance and safety. The Fusion

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range

More information

VITOSOL. Solar heating systems Flat-plate and tube collectors

VITOSOL. Solar heating systems Flat-plate and tube collectors VITOSOL Solar heating systems Flat-plate and tube collectors 2 Vitosol Solar collectors Heat from the sun: Free energy The heating system that loves the environment The sun can radiate the annual energy

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes

More information

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

VIESMANN. Installation and service instructions VITOTROL 100. for contractors Installation and service instructions for contractors VIESMANN Vitotrol 100 Type UTDB-RF2 Room temperature controller with digital time switch and wireless receiver For applicability, see the last page

More information

BTI Light commercial atmospheric water heater

BTI Light commercial atmospheric water heater Light commercial atmospheric water heater BTI - 65/85/100 Atmospheric water heater, primarily intended for light commercial / industrial applications Control, high limit and energy cut-off thermostats

More information

ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating!

ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating! ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating! Solar energy: free and inexhaustible. Energy and resources The solar age has begun. Low expenditure

More information

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K The Die competent Kompetenzmarke brand for für energy Energiesparsysteme saving systems Conventional gas fired boilers open vented / sealed unvented CGU-2 / CGU-2K CGG-2 / CGG-2K NEW The next generation

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder INSTALLATION INSTRUCTIONS Wagner& Co ECOplus Solar Cylinder Connection Diagram Hot water consumer circulation pump Backflow preventer CORREX-UP impressed current anode Safety valve, 10 bar Hot water connection,

More information

SOLAR HEATING SYSTEMS. www.orkli.com

SOLAR HEATING SYSTEMS. www.orkli.com SOLAR HEATING SYSTEMS www.orkli.com // 2 Orkli is one of the main European manufacturers of components for household appliances and innovative solutions for the comfort sector. Its corporate activity is

More information

StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS StainlessLite Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS Gledhill built on service, quality and tradition The Gledhill

More information

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water Torrent ECO Open vented thermal store providing heating and mains pressure hot water SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS The final piece in your heating and hot water system What is a thermal

More information

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name. ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the

More information

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as

More information

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:

More information

Water heating systems. Module 6

Water heating systems. Module 6 Water heating systems Module 6 Contents Introduction Module 6.1 Water Heating Systems Module 6.2 Water Heating System Fuel Types Module 6.3 Standardised Operation Conditions Module 6.4 Water Heating Systems

More information

MADE IN GERMANY. Valves, controls + systems Thermal solar energy Stations, controllers, collectors, accessories, service, software

MADE IN GERMANY. Valves, controls + systems Thermal solar energy Stations, controllers, collectors, accessories, service, software Innovation + Quality Valves, controls + systems Thermal solar energy Stations, controllers, collectors, accessories, service, software Product range Award: MADE IN GERMANY Thermal solar energy Content

More information

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert. Price List Rev.2 2010 AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.com SOMMARIO INDEX SOLAR SYSTEMS... page 10 COMPONENTS

More information

Zenith Solar thermal 4.5m pump station Installation manual

Zenith Solar thermal 4.5m pump station Installation manual Zenith Solar thermal 4.5m pump station Installation manual Product code: 20026145 INSTALLATION MANUAL WATER RETURN GROUP This instruction manual is an integral part of the installation and maintenance

More information

DHW storage tanks VITOCELL. Heating Systems Industrial Systems Refrigeraation Systems

DHW storage tanks VITOCELL. Heating Systems Industrial Systems Refrigeraation Systems DHW storage tanks VITOCELL Heating Systems Industrial Systems Refrigeraation Systems Vitocell domestic hot water storage tanks 4 to 9 USG / 60 to 450 ltr / Rediscover domestic hot water comfort With a

More information

Session 2: Hot Water Supply

Session 2: Hot Water Supply MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

ErP made easy! Valves, controls + systems. Guideline Individual packages according to ErP with high energy efficiency and a good benefit/cost ratio

ErP made easy! Valves, controls + systems. Guideline Individual packages according to ErP with high energy efficiency and a good benefit/cost ratio Valves, controls + systems Innovation + Quality Guideline Individual packages according to ErP with high energy efficiency and a good benefit/cost ratio ErP made easy! ErP Directive Content ErP Directive

More information

Natural geothermal energy.

Natural geothermal energy. ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.

More information

Installation and Service Instructions for use by heating contractor SM1 SOLAR CONTROL MODULE IMPORTANT

Installation and Service Instructions for use by heating contractor SM1 SOLAR CONTROL MODULE IMPORTANT Installation and Service Instructions for use by heating contractor Solar Control Module for solar connections to the Vitotronic control SM1 SOLAR CONTROL MODULE Product may not be exactly as shown IMPORTANT

More information

Itho Products for Hot and Boiling water. product-

Itho Products for Hot and Boiling water. product- Itho Products for Hot and Boiling water product- 2 This booklet provides additional information on the range of hot and boiling water appliances by Itho. The data will allow you to determine which product

More information

Solar Thermal Systems

Solar Thermal Systems Solar Thermal Systems Design and Applications in the UAE Murat Aydemir Viessmann Middle East FZE General Manager (M.Sc. Mech.Eng., ASHRAE) Dubai Knowledge Village Congress Centre, Dubai 20.4.2009 Viessmann

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Vitocaldens 222-F Compact Gas-Hybrid appliance

Vitocaldens 222-F Compact Gas-Hybrid appliance Vitocaldens 222-F Compact Gas-Hybrid appliance Heating systems Industrial systems Refrigeration systems 2/3 Vitocaldens 222-F: The future-proof energy-source mix in one appliance Choosing Vitocaldens

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions Part No. 130009 Iss. 12 August 2004 Elson www.elsonhotwater.co.uk Open Vented Thermal Store providing mains pressure hot water heated by electricity Installation, Servicing and User's Instructions Read

More information

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME UNDERSTANDING HOT WATER SYSTEMS IN THE HOME This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

Sustainable water heating solutions through solar systems

Sustainable water heating solutions through solar systems VIESMANN Sustainable water heating solutions through solar systems Murat Aydemir Managing Director Viessmann Middle East FZE Viessmann is a Registered Provider with The American Institute of Architects

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

ComfortLine gas fired condensing boilers

ComfortLine gas fired condensing boilers The competent brand for energy saving systems ComfortLine gas fired condensing boilers Wall mounted gas fired condensing boilers CGB / CGB-K Gas fired condensing centres CGS / CGW ComfortLine gas fired

More information

Parker Indirect Fired Hot Water Boiler

Parker Indirect Fired Hot Water Boiler Parker Indirect Fired Hot Water Boiler Mfg: Parker Model: WH-970 Stock No. CGCB074.1 Serial No. Parker Indirect Fired Hot Water Boiler. Model: WH-970. MAWP: 125 psi., heating surface: 103.5 sq. ft. Horse

More information

HOT WATER SYSTEMS. www.thermann.com.au

HOT WATER SYSTEMS. www.thermann.com.au HOT WTER SYSTEMS www.thermann.com.au GS HOT WTER SYSTEM The Thermann 4 star Gas hot water heater can suit almost any family type. With an adjustable thermostat for safety and efficiency it allows you to

More information

maximise the sun s energy with warmflow solar Warmflow Solar

maximise the sun s energy with warmflow solar Warmflow Solar maximise the sun s energy with warmflow solar Warmflow Solar Warmflow Solar warmflow solar - the perfect choice Warmflow has been established as a privately owned company since 1970. During this time we

More information

BRAVA small size, big performance

BRAVA small size, big performance BRAVA small size, big performance www.sime.it BRAVA: small size, big performance Brava Slim and Brava One are part of a new generation wall hung boilers, particularly compact and functional. They represent

More information

INSTALLATION & TECHNICAL MANUAL

INSTALLATION & TECHNICAL MANUAL The COMET Range of Boilers the ultimate solution for central heating INSTALLATION & TECHNICAL MANUAL If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: info@electric-heatingcompany.co.uk

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Operating instructions

Operating instructions Operating instructions Gas condensing boilers MGK-130 MGK-170 MGK-210 MGK-250 MGK-300 Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de Document

More information

building engineering services association specification for: Domestic Heating www.thebesa.com

building engineering services association specification for: Domestic Heating www.thebesa.com building engineering services association specification for: Domestic central Heating installation www.thebesa.com building engineering services association acknowledgments Guide to good practice: Domestic

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Description of functions

Description of functions Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the

More information

INSTRUCTIONS FOR USE AND INSTALLATION OF AN ACCUMULATOR TANK

INSTRUCTIONS FOR USE AND INSTALLATION OF AN ACCUMULATOR TANK INSTRUCTIONS FOR USE AND INSTALLATION OF AN ACCUMULATOR TANK TABLE OF CONTENTS 1 OVERVIEW.. 5 2 TRANSPORTATION 6 3 POSITIONING. 6 4 DIMENSIONS. 7 4.1 Dimensions of the Accumulator tank 7 4.2 Domestic Hot

More information

Steam Generators. & SPA Accessories

Steam Generators. & SPA Accessories Steam Generators & SPA Accessories HygroMatik steam generators Different performance classes for all kinds of uses HygroMatik steam generators produce mineral-free, hygienic steam for the modern application

More information

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS Solar MAX ELECTRIC BOOSTED SPECIFICATIONS Proudly Australian ALL AUSSIE GAS & ELECTRIC BOOSTED WATER S Harness the power of the Sun. 1 Energy efficiency that s out of this world AquaMAX high efficiency

More information

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and

More information

Heating with wood the most natural fuel in the world

Heating with wood the most natural fuel in the world Heating with wood 2/3 Heating with wood the most natural fuel in the world The rising cost of fossil fuels and growing environmental awareness are resulting in an ever-increasing demand for renewable

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

ROTEX gas hybrid heat pump. A strong team.

ROTEX gas hybrid heat pump. A strong team. ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat

More information

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store

More information

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet

More information

HYBRID HEAT PUMPS. Switch over to more efficiency, even in old buildings. Air/water system for heating HBW series. Quality with systems. max.

HYBRID HEAT PUMPS. Switch over to more efficiency, even in old buildings. Air/water system for heating HBW series. Quality with systems. max. HYBRID HEAT PUMPS Switch over to more efficiency, even in old buildings max. 90 Inlet temperature Air/water system for heating HBW series 1-2015 Quality with systems THE HYBRID TREND TECHNOLOGY Two technologies

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Solar Collector Series. Product List

Solar Collector Series. Product List Solar Collector Series List FULL COLLECTORS (MANIFOLD, TUBES & ROOF FRAME) : CSR00051 Apricus Collector : AP10 10-Way Manifold, 10 Tubes and Standard Roof Frame CSR00052 Apricus Collector : AP20 20-Way

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Professional Report. Map section. Location of the system. Valkkinen Longitude: 23.667 Latitude: 61.267 Elevation: 89 m

Professional Report. Map section. Location of the system. Valkkinen Longitude: 23.667 Latitude: 61.267 Elevation: 89 m Puulämmitys 6 x SF3 Location of the system Map section Valkkinen Longitude: 23.667 Latitude: 61.267 Elevation: 89 m This report has been created by: Samppa Takala Samppa Takala Nyrhintie 14 28760 Pori

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Air Source Heat Pump Installation and Maintenance Manual

Air Source Heat Pump Installation and Maintenance Manual Air Source Heat Pump Installation and Maintenance Manual Model Numbers: RC090MHXEA RC160MHXEA January 2013 www.samsungehs.co.uk Hendra - January 2013 1 The outdoor unit (boiler) Deciding on Where to Install

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

10% better heat transfer using our patented Micro Plate TM technology. Global Price List January

10% better heat transfer using our patented Micro Plate TM technology. Global Price List January Danfoss District Energy Global Price List January 2015 Light Duty Stations 10% better heat transfer using our patented Micro Plate TM technology. www.district-heating.danfoss.com Danfoss District Energy

More information

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special

More information

STATIONARY WATER HEATERS

STATIONARY WATER HEATERS OPERATING AND INSTALLATION MANUAL STATIONARY WATER HEATERS OKCE 100 NTR / 2,2 kw OKCE 125 NTR / 2,2 kw OKCE 160 NTR / 2,2 kw OKCE 200 NTR / 2,2 kw OKCE 250 NTR / 2,2 kw OKCE 300 NTR / 2,2 kw OKCE 300 NTR

More information

TECHNICAL DATA SHEET. Fresh water unit FWS-V200

TECHNICAL DATA SHEET. Fresh water unit FWS-V200 TECHNICAL DATA SHEET Fresh water unit FWS-V FWS-V-14 with circulation FWS-V-14 without circulation FWS-V- with circulation FWS-V- without circulation FWS-V- with circulation FWS-V- without circulation

More information

9CAST IRON FUEL OIL / GAS BOILERS

9CAST IRON FUEL OIL / GAS BOILERS EASYLIFE PROJECT GT / GTU 0 GTU 0 GTU 0 FF 9CAST IRON FUEL OIL / GAS OILERS POWER RANGES GT COERCIAL OUTPUTS see page GTU 0... 6-9 kw p. 06 GTU 00... 6-9 kw p. 07 GTU 00/V 0. 6- kw p. 07 GTU 00 GTU 00

More information

SOLAR HOT WATER SOLUTIONS stainless steel roof systems

SOLAR HOT WATER SOLUTIONS stainless steel roof systems SOLAR HOT WATER SOLUTIONS stainless steel roof systems RHEEM. SINCE 1937. Rheem has been manufacturing in Australia since 1937. Over seventy-five years later, Rheem is a household name and is as much a

More information

Open Vented Thermal Store to provide mains pressure domestic hot water. Coral Aquanox

Open Vented Thermal Store to provide mains pressure domestic hot water. Coral Aquanox Open Vented Thermal Store to provide mains pressure domestic hot water Coral Aquanox Open Vented Thermal Store to provide mains pressure domestic hot water Coral Aquanox Elson is part of the BDR Thermea

More information

Megaflo eco. Unvented hot water cylinders

Megaflo eco. Unvented hot water cylinders Megaflo eco Unvented hot water cylinders Megaflo eco. Better for you, your customers and your environment. Our Megaflo eco range is the best choice for conserving energy while providing superior performance.

More information

Water Heating Catalogue

Water Heating Catalogue CI/SfB (53.3) x July 2012 Water Heating Catalogue Introduction 2 A Leading Name Santon has been a leading name in water heating for over seventy years with a comprehensive product portfolio, which includes

More information

Water Chillers - The range CH and RPW series

Water Chillers - The range CH and RPW series Water Chillers - The range CH and RPW series PIOVAN S.p.A. Cooling Centre 1 (1) Piovan Chiller Range Piovan Spa 03.2004 Modification reserved Water chillers A dedicated Cooling Centre Integration with

More information

SOLID FUEL BOILERS LEADER IN SOLID FUEL BOILERS WOOD AND PELLET BOILERS FERROLI SOLID FUEL RANGE

SOLID FUEL BOILERS LEADER IN SOLID FUEL BOILERS WOOD AND PELLET BOILERS FERROLI SOLID FUEL RANGE SOLID FUEL BOILERS SOLID FUEL BOILERS LEADER IN SOLID FUEL BOILERS Ferroli, in line with its position as a comfort multinational, one of the major players at a world level, permanently carries out research

More information

The complete heating system.

The complete heating system. ROTEX EcoHybrid The complete heating system. ROTEX EcoHybrid renewable energy sources perfectly combined. "We had no idea how complicated selecting the right heating system for our house would be. Fortunately

More information

INSTALLATION INSTRUCTIONS FOR ALBION ULTRASTEEL UNVENTED CYLINDERS: DIRECT, INDIRECT AND SOLAR MODELS.

INSTALLATION INSTRUCTIONS FOR ALBION ULTRASTEEL UNVENTED CYLINDERS: DIRECT, INDIRECT AND SOLAR MODELS. IMPORTANT NOTE TO THE INSTALLER Read these instructions before commencing installation. Unvented cylinders are a controlled service as defined in the latest edition of the building regulations and should

More information

Operating instructions

Operating instructions 6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump your comfort. our world. Daikin Altherma Hybrid Heat Pump The natural combination Heating Integrated Solutions Ventilation Air Conditioning Refrigeration About Daikin Forward thinking... Daikin has a worldwide

More information

Heating with oil. Heating systems Industrial systems Refrigeration systems

Heating with oil. Heating systems Industrial systems Refrigeration systems Heating with oil Heating systems Industrial systems Refrigeration systems 2/3 Heating with oil technology with up to 98 percent efficiency On the following pages you will find extensive information about

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump your comfort. our world. Daikin Altherma Hybrid Heat Pump Smart heating technology for the best of both worlds Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Forward thinking About

More information

NIBE ACCESSORIES. NIBE Accessories A NEW GENERATION OF HEAT PUMPS

NIBE ACCESSORIES. NIBE Accessories A NEW GENERATION OF HEAT PUMPS NIBE ACCESSORIES NIBE Accessories A NEW GENERATION OF HEAT PUMPS OVERVIEW Extract of NIBE Accessories Ground source heat pumps VPB 200 VPB 300 VPBS 300 VPB 500 750 1000 VPAS AHPS/ AHP HPAC 40 45 PCM 40

More information

Create the right atmosphere with renewables.

Create the right atmosphere with renewables. The complete ROTEX heat pump product range Create the right atmosphere with renewables. ROTEX air-to-water and ground source heat pumps for new build and modernisation. The inexhaustible heat source on

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

Mounting and operating instructions. Fresh water station WHI freshaqua 44 #1 Fresh water station WHI freshaqua 55 #1 83514402 1/2014-03

Mounting and operating instructions. Fresh water station WHI freshaqua 44 #1 Fresh water station WHI freshaqua 55 #1 83514402 1/2014-03 Mounting and operating instructions Fresh water station WHI freshaqua 44 #1 Fresh water station WHI freshaqua 55 #1 83514402 1/2014-03 1 Information for the user... 5 1.1 User guidance... 5 1.1.1 Symbols...

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump Daikin Altherma Hybrid Heat Pump Smart technology for the best of both worlds NATIONAL HEAT PUMP 19 JUNE 2014 ICC BIRMINGHAM WINNER Forward thinking Now is the time to rethink the way we heat our homes

More information

DOM 9: GUIDE TO THE DESIGN OF ELECTRIC WATER HEATING SYSTEMS FEBRUARY

DOM 9: GUIDE TO THE DESIGN OF ELECTRIC WATER HEATING SYSTEMS FEBRUARY DOM 9: GUIDE TO THE DESIGN OF ELECTRIC WATER HEATING SYSTEMS FEBRUARY 2006 The Electric Heating and Ventilation Association Westminster Tower, 3 Albert Embankment, London SE1 7SL t: +44 (0) 20 7793 3008

More information

LK Electric Boiler - 4,5

LK Electric Boiler - 4,5 LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered

More information

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction

More information

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50

More information

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH Centauri Condensing Fire Tube Water Boiler 399 to 1000 MBH Pre-mix surface burner with up to a 7-to-1 turndown NOx levels as low a 5 ppm at full rate Operates on 4" gas pressure shown with optional gauges

More information

YUTAKI S. Domestic Heating

YUTAKI S. Domestic Heating YUTAKI S ECOLOGY & COMFORT OUTDOOR UNIT RAS 3HVRNME-AF YUTAKI-S MODULE RWM 2~10.0HFSN3E The Yutaki S heat pump is the ideal solution both in new installations and refurbishments. Its exceptional performance

More information