Name Comment Datatype Scale & Unit. The version number for fieldbus list used in this switch box.

Size: px
Start display at page:

Download "Name Comment Datatype Scale & Unit. The version number for fieldbus list used in this switch box."

Transcription

1 Switchbox Wilo-Control with Modbus MSTP interface / FC/ Installation For install on unisolated S485 interface on Pin 67 (A- and Pin 68 (B+ and for and FC install on the isolated S485 interface on Pin 69 (A- and Pin 70 (B+. To Working description of the system A connection of the to a network will be established through the EIA 485 interface of the Modbus MSTP port. The is working as a Modbus slave. The menus for the Modbus configuration are baud rate, slave address parity and stop bits. Through Modbus some parameters of the can be read or written (see Table. System MODBUS specificati on (protocol register Name Comment Datatype Scale & Unit 40001(0 Version communicatio n profile The version number for fieldbus list used in this switch The number before the point changes if the list is incompatible with previous version. For example if new items were replaced. The number after the point changes if changes are compatible with previous version of the list. So, you only need to update your control system if you want to use new features (1 Wink service If wink service is active an indicator in the HMI is blinking for 30 seconds to help to identify the device. Parameters 0,001 BOOL Acc ess W EBA-supplemental sheet WILO-CONTOL page 1 of 9

2 40003(2 Switch box type CC CC...FC CCe Enum CC CC...FC CCe 40008(7 Switch box ID The Serial number of the switch UINT (13 Bus command timer This parameter is responsible for access via HMI and/or fieldbus. Several possibilities exist. Option "manual", HMI and fieldbus can access the switch box parameters. In this case HMI and fieldbus have the same priority and last written value is active. Option "Off", the HMI is locked completly, so only fieldbus has access. If fieldbus fails, you have no access the the switch box until fieldbus is recovered. Option "Set", HMI is locked and a five minutes timer starts and the state of this register changes to active. The "Set" option has to be send at least every five minutes to keep the active state. If Option "Set" is not send again, state changes to "eset" and HMI gets back access and fieldbus is locked. To unlock fieldbus you have to send "Set" before you can access any other register through the fieldbus (14 Drives on/off To switch the drives of all s on or off. Pump kick does not take place if drives are off which is different from Extern off (15 Pump hand PM[0] 40017(16 Pump hand PM[1] 40018(17 Pump hand PM[2] 40019(18 Pump hand PM[3] 40020(19 Pump hand PM[4] Enum - Off Set Active eset al BOOL The speed of the s in PM or %. The speed of the s in PM or %. The speed of the s in PM or %. The speed of the s in PM or %. The speed of the s in PM or %. EBA-supplemental sheet WILO-CONTOL page 2 of 9

3 40021(20 Pump hand PM[5] The speed of the s in PM or % (23 FC on/off For devices with internal frequency converter this register actives or disables the FC (24 Control mode The control mode adapts the controller to the physical quantity to be used in the application (25 Current value This data point returns the current value of the measured physical quantity. The unit depends on the active control mode (26 Active setpoint value 40028(27 Number of s 40029(28 Maximum active s BOOL Enum INT16 bar C p-c dp-c dp-v dt-c dt-v n(tv n(t n(tp n(ta n-c The active set point. The unit depends on the active control mode. INT16 bar C The total number of s present in the system. The maximum number of simultaneous s in the system (32 Pump state[0] The data point returns the state (error,,... of a as an unning eserve EBA-supplemental sheet WILO-CONTOL page 3 of 9

4 40034(33 Pump state[1] The data point returns the state (error,,... of a as an 40035(34 Pump state[2] The data point returns the state (error,,... of a as an 40036(35 Pump state[3] The data point returns the state (error,,... of a as an 40037(36 Pump state[4] The data point returns the state (error,,... of a as an 40038(37 Pump state[5] The data point returns the state (error,,... of a as an 40041(40 Pump mode[0] unning eserve unning eserve unning eserve unning eserve unning eserve The mode (on, off, auto for the single s. Enum Off EBA-supplemental sheet WILO-CONTOL page 4 of 9

5 40042(41 Pump mode[1] 40043(42 Pump mode[2] 40044(43 Pump mode[3] 40045(44 Pump mode[4] 40046(45 Pump mode[5] 40050(49 Pump actual PM[0] 40051(50 Pump actual PM[1] 40052(51 Pump actual PM[2] 40053(52 Pump actual PM[3] 40054(53 Pump actual PM[4] 40055(54 Pump actual PM[5] 40062(61 Switch box state The mode (on, off, auto for the single s. Enum Off The mode (on, off, auto for the single s. Enum Off The mode (on, off, auto for the single s. Enum Off The mode (on, off, auto for the single s. Enum Off The mode (on, off, auto for the single s. Enum Off The actual speed of the single s. Unit (rpm,% depends on switch The actual speed of the single s. Unit (rpm,% depends on switch The actual speed of the single s. Unit (rpm,% depends on switch The actual speed of the single s. Unit (rpm,% depends on switch The actual speed of the single s. Unit (rpm,% depends on switch The actual speed of the single s. Unit (rpm,% depends on switch The global state of the switch box, i.e. SBM, SSM. SBM SSM EBA-supplemental sheet WILO-CONTOL page 5 of 9

6 40068(67 Set points[0] Depending on the switch box a certain number of set points (CC: 3, : 2 can be defined here (68 Set points[1] Depending on the switch box a certain number of set points (CC: 3, : 2 can be defined here (69 Set points[2] Depending on the switch box a certain number of set points (CC: 3, : 2 can be defined here (74 External set point value 40076(75 External set point on/off 40077(76 Switch box cycles 40079(78 Switch box total hours 40081(80 Pumps switch cycles[0] 40083(82 Pumps switch cycles[1] If control mode is p-c, dp-c, dt-c, n(tx it returns the actual external value. INT16 bar bar bar bar C Enable or disable the external set point. BOOL The total number of power offs for the switch UINT32 The total on-time of the switch box in hours. UINT32 The total number of switch cycles for a. UINT32 The total number of switch cycles for a. UINT32 EBA-supplemental sheet WILO-CONTOL page 6 of 9

7 40085(84 Pumps switch cycles[2] 40087(86 Pumps switch cycles[3] 40089(88 Pumps switch cycles[4] 40091(90 Pumps switch cycles[5] 40097(96 Pumps total hours[0] 40099(98 Pumps total hours[1] 40101( ( (104 Pumps total hours[2] Pumps total hours[3] Pumps total hours[4] The total number of switch cycles for a. UINT32 The total number of switch cycles for a. UINT32 The total number of switch cycles for a. UINT32 The total number of switch cycles for a. UINT32 The total time of a in hours. UINT32 1 min The total time of a in hours. UINT32 1 min The total time of a in hours. UINT32 1 min The total time of a in hours. UINT32 1 min The total time of a in hours. UINT32 1 min EBA-supplemental sheet WILO-CONTOL page 7 of 9

8 40107( ( ( ( ( (146 Pumps total hours[5] state The total time of a in hours. UINT32 1 min The error states for the switch box as a Therefore several errors can be indicated simultaniously. 32 Sensor error P man P min FC TLS Pump 1 Pump 2 Pump 3 Pump 4 Pump 5 Pump Frost Battery Low Acknowledge Use this data point to give a receipt for an alarm. BOOL W history index history error code histogram index The error history has a certain number of entries depending on the switch box type (CC,. To access an entry provide its index here. Than you can read its values in the following registers. The code of the selected error history entry. 0,1 The error histogram has a certain number of entries depending on the number of available errors (CC, 10. To access a bin provide its index here. Than you can read its values in the following registers. EBA-supplemental sheet WILO-CONTOL page 8 of 9

9 40148( (148 histogram error code histogram error count The error code of the selected error histogram bin. 0,1 The number of occurrence of the error of the selected error histogram bin. EBA-supplemental sheet WILO-CONTOL page 9 of 9

For support on the Beijer HMI please contact: info.usa@beijerelectronics.com.

For support on the Beijer HMI please contact: info.usa@beijerelectronics.com. Date: 8 August 2008 www.quicksilvercontrols.com Beijer HMI Associated Files: - Example.VF6 (Written with H-Designer) - Profile Velocity Continuous -Beijer.qcp Overview The Human Machine Interface (HMI)

More information

The Answer to the 14 Most Frequently Asked Modbus Questions

The Answer to the 14 Most Frequently Asked Modbus Questions Modbus Frequently Asked Questions WP-34-REV0-0609-1/7 The Answer to the 14 Most Frequently Asked Modbus Questions Exactly what is Modbus? Modbus is an open serial communications protocol widely used in

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2 SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2 USER MANUAL Rev. P1.11 September 13, 2006 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc. 1998,

More information

Technical Information Sheet Page 1 of 8

Technical Information Sheet Page 1 of 8 Page 1 of 8 TIS#: 293 Date: November 27, 2006 Issued by: Chris Lawlor Subject Serial Talk Through: Configuring a 3508 with itools through a 6000 Series Recorder Definition: Serial talk-through allows a

More information

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April 2015 1SFC132089M0201 1

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April 2015 1SFC132089M0201 1 Softstarters Type PSTX Fieldbus communication, Built-in Modbus RTU 1SFC132089M0201 April 2015 1SFC132089M0201 1 1 Modbus RTU The Modbus protocol is a fieldbus protocol that provides full control and status

More information

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section

More information

EVAL-UFDC-1/UFDC-1M-16

EVAL-UFDC-1/UFDC-1M-16 Evaluation Board for Universal Frequency-to- Digital Converters UFDC-1 and UFDC-1M-16 EVAL-UFDC-1/UFDC-1M-16 FEATURES Full-Featured Evaluation Board for the Universal Frequency-to-Digital Converters UFDC-1

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

1-Port R422/485 Serial PCIe Card

1-Port R422/485 Serial PCIe Card 1-Port R422/485 Serial PCIe Card Installation Guide 1. Introduction Thank you for purchasing this 1-Port RS422/485 Serial PCI Express (PCIe) Card. It is a universal add in card that connects to a PC or

More information

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master Page 1 of 13 Table of Contents 1 OVERVIEW... 3 2 INSTALLING AND CONFIGURING THE ANYBUS -X GENERIC GATEWAY AND ETHERNET

More information

Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs

Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs AN033101-0412 Abstract This describes how to interface the Dallas 1-Wire bus with Zilog s Z8F1680 Series of MCUs as master devices. The Z8F0880,

More information

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification Assembly 025A0215 600A0942 Rev. A May 14, 2012 025A0215 Brushless DC Motor Controller Page 1 Revision History ECN # Date Rev Description

More information

Troubleshooting and Diagnostics

Troubleshooting and Diagnostics Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem

More information

How To Set Up A Protocessor Protonode

How To Set Up A Protocessor Protonode Setup Manual BACnet Protocol Gateway for TempTrac and XR Water Heater Control When a BAS interface with TempTrac or the XR requires a protocol other than the standard Modbus RTU, PVI Industries offers

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems ViewPower User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview... 2 1.1. Introduction...2 1.2. Structure...2 1.3. Applications...2 1.4. Features...2

More information

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL 80202201 (Rev. 2.1)

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL 80202201 (Rev. 2.1) Master-Touch and ValuMass Modbus Communications INSTRUCTION MANUAL 80202201 (Rev. 2.1) Eldridge Products, Inc. 2700 Garden Road, Building A Monterey, CA 93940 Tel: 800/321-3569 or 831/648-7777 Fax: 831/648-7780

More information

Keep it Simple Timing

Keep it Simple Timing Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring

More information

Instructions. ECL Comfort 210 / 310, communication description. Table of Contents

Instructions. ECL Comfort 210 / 310, communication description. Table of Contents Table of Contents 1. Introduction... 3 2. ECL Comfort 210/310 communication interfaces... 4 3. USB service port... 5 3.1 USB driver installation... 5 4. RS-485 Modbus... 6 4.1 RS-485 network description...

More information

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate

More information

EGCP-3 MC 8406-114 Revision H Software 5448-145 Revision F. Explanation of Software Changes Made for the EGCP-3 MC Control. Application Note 51298

EGCP-3 MC 8406-114 Revision H Software 5448-145 Revision F. Explanation of Software Changes Made for the EGCP-3 MC Control. Application Note 51298 EGCP-3 MC 8406-114 Revision H Software 5448-145 Revision F Explanation of Software Changes Made for the EGCP-3 MC Control Application Note 51298 WARNING DANGER OF DEATH OR PERSONAL INJURY WARNING FOLLOW

More information

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions

More information

EGCP-3 LS 8406-113 Revision L. Explanation of Software Changes Made for the EGCP-3 LS Control. Application Note 51294

EGCP-3 LS 8406-113 Revision L. Explanation of Software Changes Made for the EGCP-3 LS Control. Application Note 51294 EGCP-3 LS 8406-113 Revision L Explanation of Software Changes Made for the EGCP-3 LS Control Application Note 51294 WARNING DANGER OF DEATH OR PERSONAL INJURY WARNING FOLLOW INSTRUCTIONS Read this entire

More information

RcWare SoftPLC Modbus server mapping editor User manual

RcWare SoftPLC Modbus server mapping editor User manual RcWare SoftPLC Modbus server mapping editor User manual 1 Contents 1 Contents... 2 2 Why SoftPLC as a Modbus server... 3 3 Installation and setup of the Modbus mapping editor... 4 4 Creating and editing

More information

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX Mitsubishi Heavy Industries AC IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)

More information

DUKANE Intelligent Assembly Solutions

DUKANE Intelligent Assembly Solutions PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc

More information

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement BAnet Protocol Implementation onformance Statement Date: November 13, 2012 Vendor Name: ABB Inc Product Name: Low Voltage A Motor Drive Product Model Number: AS320 Applications Software Version: 403 Firmware

More information

MeetMe Conferencing. Quick Reference

MeetMe Conferencing. Quick Reference MeetMe Conferencing Quick Reference 2013 8156 S. Wadsworth Blvd, Suite E-354 Littleton, CO 80128 www.ipitimi.com sales@ipitimi.com 1-855-IPITIMI (474-8464) MEET-ME CONFERENCIING Creating Conferences Access

More information

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600 User Manual Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600 2 1. Introduction 1. Introduction 1.1 Introduction Thank you for choosing an EFOY product. Please read

More information

Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface

Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Application te Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Abstract This

More information

Hydras 3 LT Quick Start

Hydras 3 LT Quick Start Catalog Number 6234218 Hydras 3 LT Quick Start SOFTWARE MANUAL December 2005, Edition 2 Hach Company, 2005. All rights reserved. Printed in the U.S.A. Catalog Number 6234218 Hydras 3 LT SOFTWARE MANUAL

More information

2-Port RS232/422/485 Combo Serial PCI Card

2-Port RS232/422/485 Combo Serial PCI Card 2-Port RS232/422/485 Combo Serial PCI Card Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial PCI Card. It is a universal add in card that connects to a

More information

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts Rubbermaid Medical Solutions Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts REVISED FEBRUARY 25, 2010 Filename: Cart Interface Installation & Control Board

More information

EtherNet/IP Scanner Configuration for the Moxa MGate 5105-MB-EIP

EtherNet/IP Scanner Configuration for the Moxa MGate 5105-MB-EIP the Moxa MGate 5105-MB-EIP Contents Moxa Technical Support Team support@moxa.com 1. Introduction... 2 2. Applicable Products... 2 3. System Requirements... 2 4. System Overview... 2 5. Configuring a Moxa

More information

Installation and Operation. Manual

Installation and Operation. Manual S e a N e t - A l a r m U S B Installation and Operation Manual Hardware Version V 1.1 Software Version 1.00 March 2009 2004 All Rights Reserved http://www.gadgetpool.de 2004 Alle Rechte vorbehalten alarm@gadgetpool.de

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 Telephone : 800-876-1172 International : (979) 690-5560, Fax : (979) 690-0440 e-mail : globalw@globalw.com

More information

APR-PRT3 Printer Module: C-Bus Programming Instructions

APR-PRT3 Printer Module: C-Bus Programming Instructions APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us

More information

Meet Me Conferencing. Document Date: 05/15/2015 Document Version: 1.0d

Meet Me Conferencing. Document Date: 05/15/2015 Document Version: 1.0d Meet Me Conferencing Document Date: 05/15/2015 Document Version: 1.0d Creating Conferences Access You have access to Conferencing features if you have been assigned to a Meet-Me conference bridge. Go to

More information

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com

More information

Time Attendance V1.4

Time Attendance V1.4 Time Attendance V1.4 Installation Manual May 11, 2011 Page 1 TABLE OF CONTENTS 1. TIME ATTENDANCE...5 2. SOFTWARE INSTALLATION...6 3. SETTING UP THE TIME ATTENDANCE SYSTEM...7 3.1 Set Password...7 3.2

More information

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description... 3. 1.1 Objective... 3 1.2 Goals...

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... Moxa MGate 5105-MB-EIP Contents Moxa Technical Support Team support@moxa.com 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements...

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

PM1122 INT DIGITAL INTERFACE REMOTE

PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings

More information

Vicon Flash Upgrade Software

Vicon Flash Upgrade Software NOTES NO. REV. SEC. INSTRUCTION MANUAL Refer to XX134-11-00 1108 3 XX134 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT through a PC using the Flash Upgrade software.

More information

Bluetooth Serial Adapter

Bluetooth Serial Adapter RN-BT-SRL-UM Bluetooth Serial Adapter 0 Roving Networks. All rights reserved. RN-BT-SRL-UM-.0 Version.0 //0 USER MANUAL RN-BT-SRL-UM-.0 OVERVIEW Roving Networks offers a variety of Bluetooth serial adapters

More information

DCM. Product Brochure. Diagnostic Communication Master

DCM. Product Brochure. Diagnostic Communication Master DCM Product Brochure Diagnostic Communication Master DCM The DCM Diagnostic Communication Master is the best solution for the control of actuators from a remote control room through a two-wire transmission-mode

More information

Modbus Server SAMSUNG Air Conditioners

Modbus Server SAMSUNG Air Conditioners IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master

More information

Omron I/O Driver (Series 2) Programmable Serial Interface Card

Omron I/O Driver (Series 2) Programmable Serial Interface Card Omron I/O Driver (Series 2) Programmable Serial Interface Card USER MANUAL Rev. P1.55 June 8, 2012 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc. 1998, 1999.

More information

How To Use An American Zw.Com V20-20 (V20) V20 (Veu) V2.20 (Femalese) V1.2.2 (V2.1) V3.

How To Use An American Zw.Com V20-20 (V20) V20 (Veu) V2.20 (Femalese) V1.2.2 (V2.1) V3. Cover SINAMICS V: Speed Control of a V20 with S7-1200 via USS Protocol in TIA Portal SINAMICS V20, SIMATIC S7-1200 Short Documentation November 2012 Applications & Tools Answers for industry. Siemens Industry

More information

This guide describes the details that are necessary for making a HMI (PC RT or panel) for an S5 PLC.

This guide describes the details that are necessary for making a HMI (PC RT or panel) for an S5 PLC. Page 1 of 8 HOWTO_setup_and_connect_panel_to_S5.doc date: 20-01-11. - JMP / 6011 This guide describes the details that are necessary for making a HMI (PC RT or panel) for an S5 PLC. A typical application

More information

User Guide Reflow Toaster Oven Controller

User Guide Reflow Toaster Oven Controller User Guide Reflow Toaster Oven Controller Version 1.5-01/10/12 DROTEK Web shop: www.drotek.fr SOMMAIRE 1. Introduction... 3 2. Preparation of THE REFLOW CONTROLLER... 4 2.1. Power supply... 4 2.2. USB

More information

Vicon Flash Upgrade Software

Vicon Flash Upgrade Software INSTRUCTION MANUAL Notes Refer to XX134 NO. XX134-13-01 REV. 1212 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT and Surveyor -Mini Camera Domes through a PC using

More information

FUTURELIGHT RDM PC DIRECTOR

FUTURELIGHT RDM PC DIRECTOR FUTURELIGHT RDM PC DIRECTOR User manual rev. 1.3 Contents INTRODUCTION... 3 ABOUT LIGHTING NORMS... 3 INSTALLATION... 3 Connections... 5 Software upgrade... 5 THE PC SOFTWARE... 5 MENU - ABOUT... 6 MENU

More information

User Guide Win7Zilla

User Guide Win7Zilla User Guide Win7Zilla Table of contents Section 1: Installation... 3 1.1 System Requirements... 3 1.2 Software Installation... 3 1.3 Uninstalling Win7Zilla software... 3 Section 2: Navigation... 4 2.1 Main

More information

Fanuc 0 M/T Model C Serial (RS232) Connection Guide

Fanuc 0 M/T Model C Serial (RS232) Connection Guide Memex Automation Inc., Burlington, Ontario Canada L7N 1 http://www.memex.ca Fanuc 0 M/T Model C Serial (RS232) Connection Guide The Fanuc 0-C control has two RS-232 interfaces. Interface number 1 (M5)

More information

Software Upgrade Instructions for Field Conversion of EGCP-2 Controls: Application Note 51270 (Revision NEW, 11/2005) Original Instructions

Software Upgrade Instructions for Field Conversion of EGCP-2 Controls: Application Note 51270 (Revision NEW, 11/2005) Original Instructions Application Note 51270 (Revision NEW, 11/2005) Original Instructions Software Upgrade Instructions for Field Conversion of EGCP-2 Controls: 8406-120 A, B, C, D, E, and F to 8406-120 G 8406-121 A, B, C,

More information

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

E-Mon Communication Gateway Utility Instructions for BACnet/mstp E-Mon Communication Gateway Utility Instructions for BACnet/mstp The E-Mon Communication Gateway utility will allow you to configure the Device Instance (Node ID) and other parameters needed for your BACnet/mstp

More information

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3 Contents Moxa Technical Support Team support@moxa.com 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...

More information

User s Manual. Management Software for Uninterruptible Power Supply Systems

User s Manual. Management Software for Uninterruptible Power Supply Systems PowerShield NetGuard User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. NetGuard Overview...2 1.1. Introduction...2 1.2. Structure...2 1.3. Applications...3

More information

AN00140-003: Using Wago CANOpen IO

AN00140-003: Using Wago CANOpen IO AN00140-003: Using Wago CANOpen IO Overview Baldor now offers WAGO Modular IO Systems for use with Mint Motion Controllers using the CANOpen field bus interface. The WAGO units provide a very flexible

More information

The most complete Classroom Management Software

The most complete Classroom Management Software The most complete Classroom Management Software Interactivity Collaboration Communicatio Control Multimedia Assesment Messages Broadcast Sharing Remote Monitoring www.snetclass.net Key Features Snetclass

More information

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04. DOORKING SYSTEMS ACCESS CONTROL SOLUTIONS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS REV 04.11 LOCAL AREA NETWORK (LAN) CONNECTION Ethernet Connection: An Ethernet Cable, or wireless connection must

More information

MeshBee Open Source ZigBee RF Module CookBook

MeshBee Open Source ZigBee RF Module CookBook MeshBee Open Source ZigBee RF Module CookBook 2014 Seeed Technology Inc. www.seeedstudio.com 1 Doc Version Date Author Remark v0.1 2014/05/07 Created 2 Table of contents Table of contents Chapter 1: Getting

More information

ViewPower User Manual

ViewPower User Manual ViewPower User Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview... 1 1.1. Introduction... 1 1.2. Structure... 1 1.3. Applications... 1 1.4. Features...

More information

KCU Communication. PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules. System requirement: Windows XP or above

KCU Communication. PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules. System requirement: Windows XP or above KCU Communication PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules System requirement: Windows XP or above KCU Communication PC Software User Guide TABLE OF CONTENTS SECTION

More information

Brushless DC Motor Controller Product Specification Assembly 025F0129

Brushless DC Motor Controller Product Specification Assembly 025F0129 Brushless DC Motor Controller Product Specification Assembly 025F0129 September 16, 2009 025F0129 ST B Brushless DC Motor Controller Data Sheet Page 1 Revision History ECN # Date Rev Description By 07058

More information

Adaptability to Enhanced Security

Adaptability to Enhanced Security Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access

More information

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,

More information

PNSPO! Modbus Solution CP1H / CP1L / CJ1 / CJ2 / CS1. Version 2.05 6/18/2009

PNSPO! Modbus Solution CP1H / CP1L / CJ1 / CJ2 / CS1. Version 2.05 6/18/2009 PNSPO!! Modbus Solution CP1H / CP1L / CJ1 / CJ2 / CS1 Version 2.05 6/18/2009 Section 1. Overview The Omron CP1H and CP1L PLCs offer a built in function called Easy Modbus, that performs a Modbus RTU Master

More information

UDG1000 Hach PCX2200 Serial Port Input Driver configuration

UDG1000 Hach PCX2200 Serial Port Input Driver configuration UDG1000 Hach PCX2200 Serial Port Input Driver configuration Introduction: The UDG1000 Hach PCX2200 Serial Port Input Driver is used to collect data from one or more daisy-chained Hach 2200 PCX Particle

More information

AirPatrol WiFi Full Manual V1.0

AirPatrol WiFi Full Manual V1.0 AirPatrol WiFi Full Manual V1.0 Index What AirPatrol WiFi does? 3 Lights and buttons 4 WiFi Network 5 Installing AirPatrol Wifi 6 Quick Setup steps 7 AirPatrol WiFi setup 8 Sending commands (Low heat mode)

More information

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:

More information

EZ-View Network Communications Guide www.cszindustrial.com

EZ-View Network Communications Guide www.cszindustrial.com Network Communications Guide EzView Network Communications Guide RevB July 2013 (V2.2) Supersedes: RevA (May 2011) Cincinnati Sub-Zero Products, LLC 513-772-8810 12011 Mosteller Road Cincinnati, Ohio 45241

More information

Adaptability to Enhanced Security

Adaptability to Enhanced Security Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access

More information

ACTi Streaming Explorer User s Manual Ver 2.1.09

ACTi Streaming Explorer User s Manual Ver 2.1.09 ACTi Streaming Explorer User s Manual Ver 2.1.09 2011/06/24 Overview Streaming Explorer is a Web tool used to manage devices remotely. The Functions provided include Connection, PTZ, DI/DO, Motion, Camera

More information

IP Link Device Interface Communication Sheet

IP Link Device Interface Communication Sheet This document provides additional assistance with wiring your Extron IP Link enabled product to your device. Different components may require a different wiring scheme than those listed below. For complete

More information

ONE POS User Manual. A brief hand guide for ONE ERP POS SYSTEM MYIT SOLUTION. Latest update on: 03/09/12

ONE POS User Manual. A brief hand guide for ONE ERP POS SYSTEM MYIT SOLUTION. Latest update on: 03/09/12 ONE POS User Manual A brief hand guide for ONE ERP POS SYSTEM MYIT SOLUTION Latest update on: 03/09/12 TABLE OF CONTENTS CHAPTER 1 - SETTINGS Database Setup... 3 Printer Configuration... 5 Cash Drawer

More information

Tebis application software

Tebis application software Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices WYC81xQ

More information

Software User Guide UG-461

Software User Guide UG-461 Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment

More information

CPUs - CPU 315-2 PN/DP

CPUs - CPU 315-2 PN/DP Overview The CPU with a medium program memory and quantity framework High processing performance in binary and floating-point arithmetic Used as a central controller on production lines with central and

More information

Technical Training Module ( 30 Days)

Technical Training Module ( 30 Days) Annexure - I Technical Training Module ( 30 Days) Section 1 : Programmable Logic Controller (PLC) 1. Introduction to Programmable Logic Controller - A Brief History, Need and advantages of PLC, PLC configuration,

More information

LOCAL INTERCONNECT NETWORK (LIN)

LOCAL INTERCONNECT NETWORK (LIN) 54B-1 GROUP 54B LOCAL INTERCONNECT NETWORK (LIN) CONTENTS GENERAL INFORMATION........ 54B-2............ 54B-3 STRUCTURE................... 54B-2 54B-2 LIN refers to "Local Interconnect Network," which

More information

Instruction Manual FL

Instruction Manual FL 3. Operation Overview The most common used features (such as displaying force, peak hold, zero and changing of displayed units) can all be done by pressing a single dedicated key identified on the front

More information

User Manual Revision 2.101 English

User Manual Revision 2.101 English Document code: MN67011_ENG Revision 2.101 Page 1 of 18 User Manual Revision 2.101 English CAN / Modbus Master - Converter (Order Code: HD67011) for Website information: www.adfweb.com?product=hd67011 HD67011

More information

VLT 6000 HVAC. Contents

VLT 6000 HVAC. Contents Contents Introduction Safety...3 Safety Guidelines...3 Warnings Against Unintended Start...3 Introduction...4 About this manual...4 Assumptions...4 References...4 Trademarks...5 Programming the VLT 6000

More information

Supplemental User Guide

Supplemental User Guide Supplemental User Guide SUPPLEMENTAL GUIDE FOR UPDATG FIRMWARE ON Z-MAX TM LIGHTG CONTROL RELAY PANELS WITH MASTER CONTROL MODULE Software revision.00 an up LIT-ZMAXS-00 Rev A, August 2004 Technical Services:

More information

PDA Software Manual For the Windows CE and Mobile Operating Systems

PDA Software Manual For the Windows CE and Mobile Operating Systems PDA Software Manual For the Windows CE and Mobile Operating Systems Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560,

More information

7.6.4 Communication via BACnet MS/TP. Logical error. Maximum processing time, p2024[0] Process data monitoring time (setpoint timeout), p2040

7.6.4 Communication via BACnet MS/TP. Logical error. Maximum processing time, p2024[0] Process data monitoring time (setpoint timeout), p2040 Logical error If the slave detects a logical error within a request, it responds to the master with an "exception response". In this case, the slave sets the highest bit in the function code to 1 in the

More information

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication

More information

Kramer Electronics, Ltd. Site-CTRL and Web Access Online User Guide (Documentation Revision 2)

Kramer Electronics, Ltd. Site-CTRL and Web Access Online User Guide (Documentation Revision 2) Kramer Electronics, Ltd. Site-CTRL and Web Access Online User Guide (Documentation Revision 2) Software Version 1.9. 2902 To check that you have the latest version, go to the DOWNLOADS section of our Web

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0 SolarEdge RS485 Expansion Kit Installation Guide Version 1.0 Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in

More information

S7 for Windows S7-300/400

S7 for Windows S7-300/400 S7 for Windows S7-300/400 A Programming System for the Siemens S7 300 / 400 PLC s IBHsoftec has an efficient and straight-forward programming system for the Simatic S7-300 and ern controller concept can

More information

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian.

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian. Problem: Patton / 240T WAN Setup Platform: NetGuardian 240T This TKP is a guide to setting up a PPP to T1 WAN connection between a Patton Model 2603 Router and a NetGuardian 240T. The example in this guide

More information

OPR3301 USER MANUAL (OS version: RBJV0211 / Application version: RFJ35530)

OPR3301 USER MANUAL (OS version: RBJV0211 / Application version: RFJ35530) CAUTION: This information is subject to change without prior notice. Copyright 2010, Opticon Sensors Europe BV, all rights reserved. This manual may not, in whole or in part, be copied, photocopied, reproduced,

More information

Keeper Care System Data Manager Version 1.0

Keeper Care System Data Manager Version 1.0 Automated Inventory Solutions, Inc. User Manual Keeper Care System Data Manager Version 1.0 Automated Inventory Solutions Phone: (304)725-4801 Fax: (304)725-6983 www.aisvendors.com Email: support@aisvendors.com

More information

Table 1 below is a complete list of MPTH commands with descriptions. Table 1 : MPTH Commands. Command Name Code Setting Value Description

Table 1 below is a complete list of MPTH commands with descriptions. Table 1 : MPTH Commands. Command Name Code Setting Value Description MPTH: Commands Table 1 below is a complete list of MPTH commands with descriptions. Note: Commands are three bytes long, Command Start Byte (default is 128), Command Code, Setting value. Table 1 : MPTH

More information

Projector Control Command Reference Manual

Projector Control Command Reference Manual Projector Control Reference Manual Copyright (C) NEC Display Solutions, Ltd. 2014-2015 BDT140013 Revision 4.0 Introduction This manual describes the commands used to control an NEC-made projector from

More information