1 LAUREL ELECTRONICS, INC. Laureate Quadrature Encoder Position & Rate Meter Features Accepts low-level differential or single-ended 5V logic level outputs from quadrature encoders Quadrature count x1, x2 or x4 Combined encoder pulse rate to 250 khz Programmable display update rate up to 25/s Zero channel input 6-digit red or green LED display Universal AC power Input, Vac Isolated 5, 10 or 24 Vdc excitation output NEMA 4X, 1/8 DIN case Optional serial I/O: Ethernet, USB, RS232, RS485, Ethernet-to-RS485 converter Optional relay outputs: dual or quad relays, contact or solid state Optional isolated analog output: 4-20 ma, 0-20 ma, 0-10V, -10 to +10V Optional low voltage power: Vdc or Vac Description Position, Length or Angle Measurement The Laureate quadrature meter with the Standard counter main board accepts the A & B quadrature signals from linear encoders and shaft encoders to provide a highly accurate, scaled display of position, length, or angle in engineering units, such as ft, cm or degrees. The A & B quadrature signals are 90 out of phase, and their phase relationship determines whether up counts (+) or down counts (-) are counted. The meter totalizes the counts and then scales the total in software for display and control. A zero index signal, or Z signal, may be added as a third input to the A & B signals. Scaled Rate Measurement Use of the Extended counter main board can convert the quadrature meter from scaled position to scaled rate. For example, it can display the speed of a moving slab in ft/sec. Simultaneous display of position and rate will require two meters. The display and control output update rate for position or rate is normally set to a maximum of 25/s, as determined by a userprogrammable gate time. Quadrature Meter Capabilities One, two or four transitions may be counted at a maximum combined rate of 250 khz and be mathematically scaled for display in engineering units from -999,999 to +999,999. The quadrature board has input circuitry which may be jumpered for either single-ended input signals or for balanced line driver signals. Anti-jitter circuitry eliminates errors produced by vibration of the encoder. A zero index pulse, if available, is interpreted by the meter as indicating a zero reference for an integral number of revolutions of a rotary shaft encoder or the home position of a linear encoder. It is used by the meter for initializing and to correct for any cumulative pulse count errors. Special circuitry corrects for width of the zero index pulse. In the event of a power failure, the latest total may be stored in non-volatile memory and can be used as the starting point for counting when power resumes. Power fail save or zero index capabilities are alternate meter setup choices. Designed for system use. Optional plug-in boards include Ethernet and other serial communication boards, dual or quad relay boards, and an isolated analog output board. Laureates may be powered from Vac or optionally from Vac or Vdc. The display is available with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A builtin isolated 5, 10, or 24 Vdc excitation supply can power transducers and eliminate the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs. LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel
2 Specifications Display Readout Display Range Zero Adjust Span Adjust Indicators 6 LED digits, 7-segment, 14.2 mm (.56"), red or green LED to , XXXXEX notation beyond to to Four LED lamps Inputs Type Transitions Monitored Max Pulse Rate Position Error Differential high threshold Differential low threshold Differential common mode Single-ended high voltage Single-ended low voltage Input Resistance, typ. Differential or single-ended quadrature x1, x2 or x4 250 khz at x1, 125 khz at x2, 62.5 khz at x4 No error contributed by meter +200 mv -200 mv ± 7V 2.5V to 10V -1V to +1V 17 kohm Quadrature Position Mode Zero Adjust Span Adjust to to Quadrature Rate Mode Conversion Technique Conversion Time Gate time Time Before Zero Output Output & Display Update Time Base Accuracy Inverse period Gate time + 30 ms signal periods Selectable 10 ms to s Selectable 10 ms to s Same as conversion time Calibrated to ±2 ppm Power Voltage, standard Voltage, optional Power frequency Power consumption (typical, base meter) Power isolation Vac or Vdc Vac or Vdc DC or Hz 120 Vac, 240 Vac, 10 Vdc, 20 Vdc, 30 Vdc, 40 Vdc, 48 Vdc Excitation Output (standard) 5 Vdc 10 Vdc 24 Vdc Output Isolation 5 Vdc ± 5%, 100 ma 10 Vdc ± 5%, 120 ma 24 Vdc ± 5%, 50 ma 50 Vdc to meter ground Analog Output (optional) Output Levels Current compliance Voltage compliance Scaling Resolution Isolation 4-20 ma, 0-20 ma, 0-10V, -10 to +10V (single-output option) 4-20 ma, 0-20 ma, 0-10V (dual-output option) 2 ma at 10V ( > 5 kω load) 12V at 20 ma ( < 600Ω load) Zero and full scale adjustable from to bits (0.0015% of full scale) (dual analog outputs share the same ground) Relay Outputs (optional) Relay Types Current Ratings Output common 2 Form C contact relays or 4 Form A contact relays (NO) 2 or 4 Form A, AC/DC solid state relays (NO) 8A at 250 Vac or 24 Vdc for contact relays 120 ma at 140 Vac or 180 Vdc for solid state relays Isolated commons for dual relays or each pair of quad relays LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel
3 Isolation Serial Data I/O (optional) Board Selections Protocols Data Rates Digital Addresses Isolation Ethernet, Ethernet-to-RS485 converter, USB, USB-to-RS485 converter, RS485 (dual RJ11), RS485 Modbus (dual RJ45), RS232. Modbus RTU, Modbus ASCII, Laurel ASCII protocol 300 to baud 247 (Modbus), 31 (Laurel ASCII), Environmental Operating Temp. Storage Temp. Relative Humidity Protection 0 C to 55 C -40 C to 85 C 95% at 40 C, non-condensing NEMA-4X (IP-65) when panel mounted Mechanical LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel
4 Application Examples Using Quadrature for Cutting to Length Controlling the repetitive cutting of material to length is an excellent application of the Laureate quadrature meter. The quadrature encoder shares the shaft of a sensing wheel, whose rotation corresponds to lineal displacement of material. The meter compares the displacement reading against setpoint information, and then uses its dual relays to first slow down and then cut the material. Using Quadrature for X-Y Positioning Accurate X-Y position or rate can be obtained from two shaft encoders, which convert linear position to quadrature signals as a shaft turns. In addition to serving as a display, each Laureate can use its optional dual relay setpoint capability for closed loop control. It can also transmit data via RS-232, RS-485, or a 4-20 ma analog signal. Using Quadrature to Monitor a Drilling Operation Quadrature can be used to track position and vertical drilling speed of the bit in an oil drilling operation. A shaft encoder is rotated by a cable that moves with the drilling shaft. In this application, the same encoder signal is applied to a Laureate quadrature meter for position, and to a second quadrature meter for rate. Both meters can be scaled to read out in appropriate engineering units, such as feet and inches per minute, and can be alarmed. A Laureate 6-digit remote display could be added to read out peak rate. LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel
5 Ordering Guide Create a model number in this format: L50000QD, IPC Main Board Power Relay Output Analog Output Digital Interface Input Type L5 Standard Main Board, Green LEDs (for position) L6 Standard Main Board, Red LEDs (for position) L7 Extended Main Board, Green LEDs (for position or rate) L8 Extended Main Board, Red LEDs (for position or rate) 0 Isolated Vac 1 Isolated Vac or Vdc 1 Two 8A Contact Relays 2 Two 120 ma Solid State Relays 3 Four 8A Contact Relays 4 Four 120 ma Solid State Relays 1 Single isolated 4-20 ma, 0-20 ma, 0-10 V, -10 to +10V 2 Dual isolated 4-20 ma, 0-20 ma, 0-10V 1 RS RS485 (dual RJ11 connectors) 4 RS485 Modbus (dual RJ45 connectors) 5 USB 6 USB-to-RS485 converter 7 Ethernet 8 Ethernet-to-RS485 converter QD Quadrature Signal Conditioner Add-on Options CBL01 RJ11-to-DB9 cable. RJ11 to DB9. Connects RS232 ports of meter and PC. CBL02 USB-to-DB9 adapter cable. Combination of CBL02 and CBL01 connects meter RS232 port to PC USB port. CBL wire data cable, RJ11 to RJ11, 1 ft. Used to daisy chain meters via RS485. CBL wire data cable, RJ11 to RJ11, 7 ft. Used to daisy chain meters via RS485. CBL05 CBL06 CASE1 CASE2 IPC BOX1 BOX2 BL NL USB cable, A-B. Connects USB ports of meter and PC. USB to RS485 adapter cable, half duplex, RJ11 to USB. Connects meter RS485 port to PC USB port. Benchtop laboratory case for one 1/8 DIN meter Benchtop laboratory case for two 1/8 DIN meters Splash-proof cover NEMA-4 Enclosure NEMA-4 enclosure plus IPC Blank Lens without button pads Meter lens without button pads or Laurel logo LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel
TELEDYNE HASTINGS INSTRUMENTS
TELEDYNE HASTINGS INSTRUMENTS THCD 100 Self contained display for flow meter/controller and pressure transducers FEATURES 16-Bit Resolution ± 0.2% Reading +1 Digit Accuracy 0-5 VDC Setpoint via Front Panel
Monitor for Measurement of Speed and Detection of Direction Series D224.xxS2
D Monitor for Measurement of Speed and Detection of Series D.xxS KEY FEATURES Speed and Monitor with sensor monitoring and self-test function Frequency range 0 Hz 00 khz Analog Output 0/ 0 ma Bright red
A.4 Specifications for the CPU 224
A.4 Specifications for the CPU 224 Specifications for and Physical Size Dimensions (W x H x D) Weight Power loss (dissipation) CPU Features On-Board digital inputs On-Board digital outputs High speed counters
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Data Sheet SIMATIC S7-200 CPU 226 DC/DC/DC and CPU 226 AC/DC/Relay
SIMATIC S7-200 and Table 1 Specifications for and Physical Size Dimensions (W x H x D) Weight Power loss (dissipation) CPU Features On-board digital inputs On-board digital outputs High speed counters
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
KRAL Electronics BEM 300 and BEM 500.
KRAL Electronics BEM 300 and BEM 500. KRAL Electronics BEM 300 and BEM 500 Electronic units that are coordinated to KRAL flowmeters and their diverse applications. Coordinated to the flowmeters and their
Selector Guide. UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell
e o on rc trol Precision pa n ins entation w i t h trum an al fo d r in Selector Guide, og dig nd pulse ital a i n pu ts UNIVERSAL DIGITAL COUNTER Frequency and Period Rate and Total Integration and Square
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
COMPALARM C2C ALARM SYSTEM
INSTRUCTION MANUAL IM670-U v0.1 COMPALARM C2C ALARM SYSTEM GENERAL Compact alarm system, with a basic module of 12 signals Multiple modules coupling possibility Easy printing of the alarm points description
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
Multi-Channel Programmable DC Power Supplies
Dual and triple output models with two 30V/1.5A (45W) channels and a 6V/5A (30W) channel on the triple output supply All channels are independently controlled and have isolated outputs for maximum flexibility
Every device is developed according to international IEC standards and verified by independent certification bodies including UL and TÜV.
Test Set CMC 256 Unique test sets from the technology leader OMICRON s commitment to innovation is evident in the outstanding features and the absolute quality of its test sets. Making use of leadingedge
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
Single Channel Speed Monitor for Rotating Equipment with SIL2 requirements Series E16521D.3
E16 Single Channel Speed Monitor for Rotating Equipment with SIL2 requirements Series Front View KEY FEATURES SIL2 / IEC 61508:2010 compliant Single Channel Monitor with sensor monitoring and self-test
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
Variable Preset Counter signo 723.1
Variable Preset Counter signo 723.1 Large, 6-digit, 14 mm high LED display Up/down counter with prescaler 2 presets, one programmable as trailing preset Easy direct selection by 2 function keys 2 relay
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
- + +GF+ SIGNET 5075 Totalizing Monitor Instructions ENGLISH. Contents 1. Power Connections 2. Compatible Sensor Wiring
GF SIGNET Totalizing Monitor Instructions ENGLISH 3.0901 (B1/00) English CAUTION! Refer to this instruction manual for more details. Remove power to unit before wiring input and output connections. Follow
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Flexible Counter Series in DIN size 24 x 48 mm
Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display 2 different supply voltages available: independent of mains supply with lithium battery
IQ151 CONTROLLER DATA SHEET
IQ151 CONTROLLER DATA SHEET The IQ151 is a controller in the Trend range with 64 inputs and 32 outputs. Full DDC (direct digital control) with PID control loops is provided. The output channels may be
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
Section 16935 TELEPHONE AUTOMATIC DIALER SYSTEM
Section TELEPHONE AUTOMATIC DIALER SYSTEM PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Design Requirements: 1. Electronic monitoring system shall interface plant alarms to public telephone system or cellular
Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation
DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch
Flexible Counter Series in DIN size 24 x 48 mm
Fleible Counter Series in DIN size 24 48 mm high contrast display or brilliant 6-digit LED display different supply voltages available: independent of mains supply with lithium battery or maintenance-free
CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13
CONTENTS PAGE Chapter 1 General Information 1 Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13 Chapter 3 Alarm/Excitation Options 15 Wiring 17 Chapter
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor
CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5
Unitary Controller. Features. Description. Technical Specification Sheet Document No. 149-188P25 Rev. 6 March, 2000
Technical Specification Sheet Document No. 149-188P25 Rev. 6 March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE
Digital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
Generator Meter Model: VAAFH Installation/Operation Manual
Generator Meter Model: VAAFH Installation/Operation Manual I) Introduction The VAAFH is an ideal monitor system for 240/120 generators and grid power sources and provides monitor of load balancing on the
Unidirectional Transmitter/ Receiver Units Introduction
Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created
iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O
iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch User-definable Modbus/TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Save time and wiring cost with peer-to-peer
EasyIO FG Series User Reference v1.3. EasyIO FG Series DDC User Reference
EasyIO FG Series DDC User Reference Document Change Log 1 st April 2013 Document created. 7 th July 2013 Correct mistakes and typo error. 4 th August 2013 Restore Factory settings 10 th Sept 2013 Added
Digital and Analog I/O
70072-0127-07 TECHNICAL NOTE 02/2007 Digital and Analog I/O This document discusses the application and configuration of digital and analog inputs/outputs (I/O). Details are for both onboard I/O and external
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
Remote Sources. Facility. Router
A tally display system is an essential part of any broadcast or production environment. It must tell you where signals come from, where they go, and how they are being used. In a typical multi-production
PowerLogic Sub Meter Display (SMD and SMDOPN)
Instruction Bulletin Z203742-0B PowerLogic Sub Display (SMD and SMDOPN) CONTENTS Introduction... 2 Parts of the Sub Display... 3 Dimensional Drawing... 4 Installation... 5 Mounting the SMD... 5 Mounting
USB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications
Eight-channel Quadrature Encoder Input Device s Document Revision 1.1 May 2012 Copyright 2012 s All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. s in
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
02/11/2015
Smart "Compact" range with display CD12 Smart Part number 88974043 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions
T M. IRDH275 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 08.
T M 1 IRDH275 Series Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012021 / 08.2013 IRDH275 Series Digital ground fault monitor / ground
Transmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
AI-80 CALLER ID SIGNAL GENERATOR. Key Features. Applications. Generates both On Hook and Off Hook (Type I/II) Caller ID signals
CALLER ID SIGNAL GENERATOR Key Features Generates both On Hook and Off Hook (Type I/II) Caller ID signals Supports both FSK and DTMF Signalling Methods Supports all Caller ID Standards such as Bellcore,
USB Step and Direction Pulse Generator. User Manual
USB Step and Direction Pulse Generator User Manual 2012 Kellyware 1/15/2012 Table of Contents Table of Contents... 2 Parts List... 3 Key Features... 3 Introduction... 4 Installation... 5 Setup... 5 Wiring
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
100% electricity. Generating set controller RGK 60
00% electricity Generating set controller RGK 60 Large graphic screen for measurement and 5-language help prompt display Operating mode selection touch keys Manual control of stand-by generating set Load
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
Air flow meter Model A2G-25
Electronic pressure measurement Air flow meter Model A2G-25 WIKA data sheet SP 69.04 Applications For measuring the air flows of radial ventilators For measuring air flows in ventilation pipes and ducts
Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V
Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input
Series 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address
Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
Using installed Fieldbus Wiring to carry Ethernet Communications
Using installed Fieldbus Wiring to carry Ethernet Communications Modbus Plus, Data Highway, GE Genius, Profibus, ControlNet, DeviceNet, InterbusS and many other RS232 or RS4422 cables Key Issues when upgrading
Personal Daq/50 Series USB Data Acquisition Modules Models /54, /55, & /56
USB Data Acquisition Modules Models /5, /55, & /56 Features Multifunction data acquisition modules attach to PCs via Universal Serial Bus (USB 1.1 & 2.0 compatible) Ultra low-power design requires no external
SIMEXR SWE-73-A 1.2.3. low-cost meter in a small case input: 0/4-20 ma 0/1-5V; 0/2-10V RS-485 / Modbus RTU. Process Meters. Typical applications
Process Meters R SWE-7-A low-cost meter in a small case input: 0/4-20 ma 0/1-5V; 0/2-10V / Modbus RTU New pilot SIR-15 The SWE-7 efficiency indicators are low-cost and affordable panel-mounted digital
Wahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.
USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation
x - + - + x L L L AC SO 4-45 A DC SO 4- A ServoOne Specification x 9 - + - + x 7 x 8 X 8 Option - Technology x 6 TTL Encoder / TTL Encoder simulation Specification ServoOne Specification Option - Technology
sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES
ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS Enhanced defect detection Built-in diagnostics for press machinery Quicker setup and easier maintenance than competitive systems Lowest monitoring cost per
AC3200 INTELLIGENT BROADBAND AMPLIFIER
Kari Mäki 12.11.2009 1(8) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both
Filename: EAAM037301EN.docx Rev. 01 Date: 07/05/2013 ID Document: EAAM0373 Product: DANOUT (4 analog outputs module with RTU/CanBus Modbus protocol)
Filename: EAAM037301EN.docx Rev. 01 Date: 07/05/2013 ID Document: EAAM0373 Product: DANOUT (4 analog outputs module with RTU/CanBus Modbus protocol) 1. GENERAL CHARACTERISTICS... 3 1.1 VERSIONS AVAILABLE...
I/O MODULES AND CONVERTERS Input/Output, Control, Data-logging, Conversion
I/O MODULES AND CONVERTERS Input/Output, Control, Data-logging, Conversion Modules and converters can be used in many types of applications as: input modules (analog and logic), radio and serial transmitters,
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Short information Parameters are programmed via front-side membrane keypad
Digital remote display for Flow Meter DM /DE Universal meter UZ Indication of the quantity consumed in m³ Features LED-Display 14.2mm red Indicating range -99999... 999999 0... 3 Decimal points programmable
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
M90-19-R5. RS232 to RS422/RS485 Isolated Universal Converter. 1. Introduction. 2. Function diagram
to RS422/RS485 Isolated Universal Converter 1. Introduction The converts serial data from the standard to either RS422 or RS485. Features: Universal converter can be used with both and other manufacturer
ERMA-Electronic GmbH - Max-Eyth-Str.8-78194 Immendingen - Tel: +49(0)7462/2000-0 - Fax: +49(0)7462/2000-29. Technische Änderungen vorbehalten
Panel mounting instruments / DIN cabinets mounting different standard housing sizes different supply voltages all usual measured variables Measuring instruments programmable industrialfair execution customized
MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
S Page 608 Mar 2008 Siemens ITS
S7-200 Overview The new modular miniature controller from the SIMATIC S7 family Comprising: Controller with integrated PROFINET IO controller interface for communication between SIMATIC controllers, HMI,
Fluke 8808A Digital Multimeter Extended Specifications
Fluke 8808A Digital Multimeter Extended Specifications Making measurements is as simple as pushing a button The Fluke 8808A 5.5 digit multimeter has a broad range of functions, measuring volts, ohms and
Comprehensive Modular Genset Controller
Inteligen Click Here To Learn More Comprehensive Modular Genset Controller Brief Description The Inteligen is a comprehensive controller for single and multiple generating sets operating in standby or
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
3500/22M Transient Data Interface
3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery
H Unit Input/Output Manual
H Unit Input/Output Manual 4 INPUTS 4 OUTPUTS RS485 Table of Contents Safety Rules...Inside Front Cover. Introduction...IFC 2. Communications...IFC 2.2 Baud Rate...IFC 2.3 Modbus Address... 2.4 Speed of
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
LONWORKS Fibre Optic Converter
LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
3.5 AMP CONTROLLERS AND MOTORS SilverSterling 3.5 Amp QCI-S2-IG Controller/Drivers
Date: 5 May 2014 WWW.QUICKSILVERCONTROLS.COM Price List Notes RoHS available on most products. Check website or call for a list of compliant products. Prices subject to change without notice. QuickSilver
Laser Diode Controller LDC1000
Laser Diode Controller LDC1000 Features Applications Laser Diode Driver High power laser diode control Up to 300, 600 or 1.500W Pumping solid state and fiber lasers Up to 150A laser diode current Material
Elektor's Arduino 37 in 1 Sensor kit (Part No )
Elektor's Arduino 37 in 1 Sensor kit (Part No. 150001-91) The Elektor set for the Arduino system consists of 37 individual modules which can be used to carry out many interesting experiments using the
Programmable Relays. ZEN Series. ZEN Programmable Relays. Applications
Programmable Relays ZEN Series Relay, Timer, Counter, and Time Switch Functions Weekly Timer and Calendar Timer Functions Twin Timer Function (Separate ON/OFF Times) Two Analog Input Channels (DC Models
Starting Torque: Mass Moment of Inertia: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Flat Cable:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
Intelligent RS-485 I/O expansion unit: RU-87Pn Series
INTRODUCTION RU-87Pn series is a remote intelligent I/O expansion unit that used to expand i-87k series I/O modules over the RS-485 for industrial monitoring and controlling applications. There are more
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement