Aboveground Storage Tanks, Motor Fuel Dispensing, Flammable and Combustible Liquids. Captain Tom Ellison

Size: px
Start display at page:

Download "Aboveground Storage Tanks, Motor Fuel Dispensing, Flammable and Combustible Liquids. Captain Tom Ellison"

Transcription

1 Aboveground Storage Tanks, Motor Fuel Dispensing, Flammable and Combustible Liquids. Captain Tom Ellison Assistant Fire Marshal, Kern County Fire Department

2 What is an above ground tank system?

3 Tanks used for storage and dispensing of Class 1, 2, and 3 Flammable or Combustible Liquids.

4 Above-ground tanks for storage and dispensing of Class 1, 2, or 3 flammable and combustible liquids. What are common examples of the various flammable and combustible liquids classified by NFPA 30? Class IA Diethyl Ether, Ethylene Oxide, some light crude oils Class IB Motor and Aviation Gasolines, Toluene, Lacquers, Lacquer Thinner Class IC Xylene, some paints, some solvent based cements Class II Diesel Fuel, Jet Fuel, Paint Thinner Class IIIA Home Heating Oil Class IIIB Motor Oil, Hydraulic Fluid, Lubricating Oils

5 Above-ground tanks for storage and dispensing of Class 1, 2, or 3 flammable and combustible liquids. What are common examples of the various flammable and combustible liquids classified by NFPA 30? Class IA Diethyl Ether, Ethylene Oxide, some light crude oils Class IB Motor and Aviation Gasolines, Toluene, Lacquers, Lacquer Thinner Class IC Xylene, some paints, some solvent based cements Class II Diesel Fuel, Jet Fuel, Paint Thinner Class IIIA Home Heating Oil Class IIIB Motor Oil, Hydraulic Fluid, Lubricating Oils

6 Class 1 Liquid Motor Fuel Gasoline Aviation Gas

7 Class 2 Liquid Motor Fuels Diesel Fuel Jet Fuel

8 Storage of Class 1 and Class 2 Flammable Liquids Gasoline, Aviation Gas, Diesel Fuel, and Jet Fuel stored in above-ground tanks shall be listed and labeled as protected above-ground tanks in accordance with UL 2085! California Fire Code, 2013 (CFC) Chapter 23, Section Kern County Ordinance

9 Fire Protected Tanks, UL Above-ground tanks located outside, above grade. Above-ground tanks shall not be used for the storage of Class I, II or III liquid motor fuels, except as provided by this section. 1. Above-ground tanks used for outside, above-grade storage of Class I liquids shall be listed and labeled as protected above-ground tanks in accordance with UL 2085 and shall be in accordance with Chapter 57. Such tanks shall be located in accordance with Table

10 Fire Protected Tanks, UL 2085 Fire-Protected Tanks designed for the safe storage and dispensing of petroleum products (gasoline, diesel, fuel-oil, heating-oil, kerosene, and alcohol), chemicals and other flammable or combustible products. FireProtected Tanks are designed to withstand prolonged exposure to extreme temperatures while maintaining the temperature of the primary tank and its contents below thresholds that may ignite or rapidly combust the liquids/vapors within. Fire-Protected steel exterior tanks utilize a lightweight concrete thermal insulation material to achieve thermal protection. Fire-Protected concrete aggregate exterior tanks utilize a dense industrial grade concrete to achieve thermal protection. Both Fire-Protected aboveground tank designs have merits that are usually dependent upon specific end-user site and performance requirements. Underwriters Laboratories (UL) has issued performance standard UL-2085, Protected Secondary Containment Aboveground Tanks for Flammable and Combustible Liquids, a performance standard which requires that tank designs be third-party tested and certified as having successfully passed the following tests:

11 UL-2085 Test Summary Prolonged Fire-Test Hose-Stream Test 2-Hours at 2000 degrees F Maximum Avg. Temp.= 280 degrees F 5-minutes, 45 psig water stream after fire test 5-rounds, 150 grain, Caliber.30, M2 Ball Bullet Resistance Test Ammunition 2700 feet/second impact velocity Vehicle Impact 12,000 pounds applied over 1sq. 10mph Leakage Test After successful completion of above, leakage test performed using 5.0 psig air; tank to hold air for 1 hour without leaking

12 Protected Above-Ground Tanks UL 2085

13 Protected Above-Ground Tanks UL 2085

14 Class 3 Flammable and Combustible Liquids Motor Oil Hydraulic Fluid

15 Storage of Class IIIB Flammable or Combustible Liquid Class IIIB Liquid shall be stored and dispensed from a listed and labeled UL 2085 or UL 142 tank, shall be double walled or have secondary containment. California Fire Code 2013 (CFC), Chapter 23, section sub-section 5 Kern County Ordinance

16 A tank used for Type 3 flammable or combustible liquids (motor oil, gear oil) shall comply with UL 142 or UL 2085 standards. Each tank shall bear a permanent nameplate or marking indicating the standard used as the basis of design.

17 Kern County Fire Department Construction Information for Above Ground Tanks Installation

18 Kern County Fire Department Permit Requirements for Above-Ground Fuel Tanks 20Requirements/Aboveground%20Storage%20Tanks.pdf

19 Enforcement of Non-Permitted Above-Ground Tanks CFC General. The fire code official is hereby authorized to enforce the provisions of this code and shall have the authority to render interpretations of this code, and to adopt policies, procedures, rules and regulations in order to clarify the application of its provisions. Such interpretations, policies, procedures, rules and regulations shall be in compliance with the intent and purpose of this code and shall not have the effect of waiving requirements specifically provided for in this code.

20 2013 California Fire Code CFC Permits required. Any property owner or authorized agent who intends to conduct an operation or business, or install or modify systems and equipment which is regulated by this code, or to cause any such work to be done, shall first make application to the fire code official and obtain the required permit.

21 2013 California Fire Code CFC Existing noncompliant installations. Existing above-ground tanks shall be maintained in accordance with the code requirements that were applicable at the time of installation. Above-ground tanks that were installed in violation of code requirements applicable at the time of installation shall be made code compliant or shall be removed in accordance with Section , regardless of whether such tank has been previously inspected (see Section 106.4).

22 Systems in Violation of the California Fire Code CFC section ; Gravity and pressure dispensing. Flammable liquids shall not be dispensed by gravity from tanks, drums, barrels or similar containers. Flammable or combustible liquids shall not be dispensed by a device operating through pressure within a storage tank, drum or container

23

24

25

26

27 California State Fire Marshal Information Bulletin Issued: July 25, 2014 Underground Fuel Storage Tanks Prohibited for Use as Aboveground Fuel Storage Tanks

28 California State Fire Marshal Information Bulletin Addendum Issued: January 29, 2015 Underground Storage Tanks Being Sold as Aboveground Storage Tanks

29

30

31

32

33

Queen's University Environmental Health and Safety

Queen's University Environmental Health and Safety April, 2009 1 SOP-Chem-08 1.0 Introduction This document is intended as a guide to the Queen s University requirements for handling and storing flammable and combustible material in non-laboratories areas.

More information

Notes. Material 1. Appropriate Flammable Liquids

Notes. Material 1. Appropriate Flammable Liquids 29 CFR 1910.106 Flammable Materials Flammable Liquids Preparation 1. Read Applicable Background information and related Company Policy Chapter. 2. Make Copies of this Lesson Plan for Personnel 3. Make

More information

Waste Oil Collection / Storage

Waste Oil Collection / Storage ENVIRONMENTAL & REGULATORY SERVICES Storage Tank Regulation Section P. O. Box 7837 Madison, Wisconsin 53707-7837 TDD #: (608) 264-8777 http://www.commerce.state.wi.us http://www.wisconsin.gov Jim Doyle,

More information

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil) Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil) References: Comm 10 2009 EDITION / NFPA 30 2008 EDITION ITEM DESCRIPTION Comm 10 / NFPA General

More information

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT Reference: IFC 34&27, Denver Amendments, and NFPA 30, 33, 704 Approved: Joseph L. Gonzales, Division Chief, Fire Prevention and Investigation Division Number: IFC-3403-1 Effective Date: February 1 st 2012

More information

List of Frequently Utilized Storage Tank Standards and Practices

List of Frequently Utilized Storage Tank Standards and Practices List of Frequently Utilized Storage Tank Standards and Practices Below is a list of frequently used storage tank standards and practices from organizations that are referenced in 25 PA Code, Chapter 245.

More information

Sample Written Program. For. Flammable Liquids

Sample Written Program. For. Flammable Liquids Sample Written Program For Flammable Liquids 1 Flammable Liquids. (YOUR COMPANY NAME) Purpose Proper Storage and use of flammable liquids can significantly reduce the possibility of accidental fires and

More information

Flammable and Combustible Liquids. Slide 1 (of 23)

Flammable and Combustible Liquids. Slide 1 (of 23) Flammable and Combustible Liquids Slide 1 (of 23) Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and storage of flammable liquids

More information

MOTOR FUEL DISPENSING SAFETY

MOTOR FUEL DISPENSING SAFETY STRATEGIC OUTCOMES PRACTICE TECHNICAL ADVISORY BULLETIN January 2010 MOTOR FUEL DISPENSING SAFETY Fire! Not an alarm anyone wants to hear, especially not when the fire is burning at a major fuel source.

More information

OREGON FIRE CODE Interpretations and Technical Advisories

OREGON FIRE CODE Interpretations and Technical Advisories OREGON FIRE CODE Interpretations and Technical Advisories A collaborative service by local and state fire professionals, along with our stakeholders and customers, to provide consistent and concise application

More information

BP WIND ENERGY POLICIES AND PROCEDURES

BP WIND ENERGY POLICIES AND PROCEDURES BP WIND ENERGY POLICIES AND PROCEDURES Document Control Details 1.0 Purpose/Scope 1.1 This procedure provides the minimum requirements to be followed for the storage of flammable or combustible materials

More information

ADMINISTRATIVE SERVICES MANUAL

ADMINISTRATIVE SERVICES MANUAL Purpose Responsibilities Proper Storage and use of flammable liquids can significantly reduce the possibility of accidental fires and injuries. To minimize risk to life and properly, the requirements of

More information

The following definitions apply with regard to requirements specified in this document:

The following definitions apply with regard to requirements specified in this document: GUIDELINES FOR INSTALLATION OF TEMPORARY AND PERMANENT ABOVEGROUND DIESEL FUEL TANKS FOR EMERGENCY AND STANDBY POWER SYSTEMS LOCATED OUTSIDE OF BUILDINGS For Use by Unidocs Member Agencies or where approved

More information

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY FREQUENTLY ASKED QUESTIONS (FAQ) Question: Do fuel tanks fall under the requirements of Directive 055? No. For storage of fuels (e.g.,

More information

Shop Fabricated Aboveground Tank Construction Standards

Shop Fabricated Aboveground Tank Construction Standards Shop Fabricated Aboveground Tank Construction Standards Wayne Geyer Steel Tank Institute Fourth Biennial Freshwater Spills Symposium 2002 March 19-12, 2002 Cleveland, OH One key to clean freshwater is

More information

Alabama Air and Waste Regulatory Update

Alabama Air and Waste Regulatory Update Alabama Air and Waste Regulatory Update September 24, 2015 RSA Activity Center Montgomery, AL New Federal UST Regulations (Effective Date October 13, 2015) What Does This Mean To Me? The Current ADEM Regulations

More information

Recommended Fuel Piping Specification For UPP Piping, UL-971

Recommended Fuel Piping Specification For UPP Piping, UL-971 Recommended Fuel Piping Specification For UPP Piping, UL-971 1.0 General The primary delivery piping system shall be for suction or pressure applications and have semi-rigid coaxial type double wall construction,

More information

Presented by: Rich Perry Marsh Risk Consulting

Presented by: Rich Perry Marsh Risk Consulting Flammable and Combustible Liquids Presented by: Rich Perry Marsh Risk Consulting What s the Big Deal? Flammable and combustible liquids are easily ignited Ignite with explosive force Burn readily and give

More information

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 14.00: FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE SOLIDS OR FLAMMABLE GASES

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 14.00: FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE SOLIDS OR FLAMMABLE GASES 527 CMR 14.00: FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE SOLIDS OR FLAMMABLE GASES Section 14.01: Scope 14.02: Definitions 14.03: Storage 14.04: Handling of Flammable Fluids 14.05: Handling of Flammable

More information

OSHA Tank Venting DEFINITIONS

OSHA Tank Venting DEFINITIONS OSHA Tank Venting DEFINITIONS 1910.106 - Flammable and combustible liquids. 1910.106(a)(2) (a) Definitions. As used in this section: (2) Atmospheric tank shall mean a storage tank which has been designed

More information

NFPA 30-2008: Basic Requirements for Storage Tanks

NFPA 30-2008: Basic Requirements for Storage Tanks NFPA 30-2008: Basic Requirements for Storage Tanks New York City Metro Chapter Society of Fire Protection Engineers New York, NY February 22, 2011 NFPA 30, Flammable and Combustible Liquids Code Storage

More information

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Ethanol Vehicle and Infrastructure Codes and Standards Citations Ethanol Vehicle and Infrastructure Codes and Standards Citations This document lists codes and standards typically used for U.S. ethanol vehicle and infrastructure projects. To determine which codes and

More information

September 2008 AFC 4.6.2.1.(2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations

September 2008 AFC 4.6.2.1.(2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations FIRE CODE VARIANCE September 2008 AFC 4.6.2.1.(2) Page 1 of 5 ISSUE Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations The Alberta Fire Code (AFC) limits

More information

PROPANE AUTOGAS REPAIR AND MAINTENANCE FACILITY REQUIREMENTS

PROPANE AUTOGAS REPAIR AND MAINTENANCE FACILITY REQUIREMENTS PROPANE AUTOGAS REPAIR AND MAINTENANCE FACILITY REQUIREMENTS ROPANE AUTOG INTRODUCTION For more than 80 years, vehicles fueled by propane autogas have been a popular choice in countries around the globe.

More information

Pollution Prevention And Best Management Practices For Dry Cleaners Operating In Broward County

Pollution Prevention And Best Management Practices For Dry Cleaners Operating In Broward County FORWARD In 1991, the Broward County Environmental Protection and Growth Management Department, who was then known as the Department of Natural Resource Protection (DNRP), initiated the development of Pollution

More information

Petroleum Tanks at Municipal Facilities

Petroleum Tanks at Municipal Facilities January/February 2013 Petroleum Tanks at Municipal Facilities This document was reprinted with permission from the New York Association of Towns Talk of the Towns/Topics magazine January/February 2013

More information

Flammable liquid classes: Combustible Liquid Classes. Class IC. Class II. Class IB F.P. below 22.8 C (73 F), boiling point at or above 37.

Flammable liquid classes: Combustible Liquid Classes. Class IC. Class II. Class IB F.P. below 22.8 C (73 F), boiling point at or above 37. BCFC Part 4 Flammable and Combustible Liquids Application: BCFC Part 4 Part 4 provides for the storage, handling, use and processing of flammable liquids and combustible liquids in buildings,, structures

More information

Propane Autogas Fleets Safety & Training

Propane Autogas Fleets Safety & Training Propane Autogas Fleets Safety & Training Stuart Flatow Vice President, Safety & Training Propane Education & Research Council Fleets rely on training, garaging, repair & maintenance facilities Available

More information

A Code Review for Emergency Generators and Indoor Use of Portable Generators

A Code Review for Emergency Generators and Indoor Use of Portable Generators A Code Review for Emergency Generators and Indoor Use of Portable Generators By: the Fire and Life-Safety Group (FLS) Fire Code requires that emergency generators be stationary generators. Therefore, a

More information

OSHA Office of Training and Education 1

OSHA Office of Training and Education 1 Flammable and Combustible Liquids OSHA Office of Training and Education 1 Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and

More information

The following definitions apply with regard to requirements specified in this document:

The following definitions apply with regard to requirements specified in this document: GUIDELINES FOR INSTALLATION OF TEMPORARY AND PERMANENT ABOVEGROUND DIESEL FUEL TANKS FOR EMERGENCY AND STANDBY POWER SYSTEMS LOCATED OUTSIDE OF BUILDINGS For Use by Unidocs Member Agencies or where approved

More information

Flammable and Combustible Storage Checklist

Flammable and Combustible Storage Checklist Flammable and Combustible Storage Checklist Occupational Safety and Health Bureau Montana Department of Labor and Industry Prepared for Montana Employers by the Occupational Safety & Health Bureau Department

More information

Above Ground Liquid Storage Solutions

Above Ground Liquid Storage Solutions Above Ground Liquid Storage Solutions AVIATION FARMS/FORRESTRY/MINING FLEET/YARD OPERATION Inside Front Cover-See Cover File for Graphic MARINE MILITARY/PUBLIC SAFETY MISSION CRITICAL OPERATIONS WATER

More information

NFPA31FuelOilPiping 1 Revised 3-1-11

NFPA31FuelOilPiping 1 Revised 3-1-11 NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from

More information

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario Fire Code, Part 4, and of the Regulations for

More information

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

In accordance with NFPA 30, these containers are not to store Class I flammable liquids. In accordance with NFPA 30, these containers are not to store Class I flammable liquids. Zurich recommends storing these containers in dedicated liquid storage rooms, detached buildings, or in listed dispensing

More information

OIL STORAGE REQUIREMENTS OF THE SPCC REGULATIONS. Christopher J. Ecsedy, P.E. Fuss & O'Neill, Inc. 146 Hartford Road Manchester, CT 06040

OIL STORAGE REQUIREMENTS OF THE SPCC REGULATIONS. Christopher J. Ecsedy, P.E. Fuss & O'Neill, Inc. 146 Hartford Road Manchester, CT 06040 ABSTRACT OIL STORAGE REQUIREMENTS OF THE SPCC REGULATIONS Christopher J. Ecsedy, P.E. Fuss & O'Neill, Inc. 146 Hartford Road Manchester, CT 06040 The SPCC regulations entail numerous requirements for the

More information

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to

More information

Secondary Containment Options for Aboveground and Underground Tanks. Wayne Geyer Steel Tank Institute

Secondary Containment Options for Aboveground and Underground Tanks. Wayne Geyer Steel Tank Institute Secondary Containment Options for Aboveground and Underground Tanks Wayne Geyer Steel Tank Institute Secondary containment tanks first appeared in the United States in the early 1980's, when several local

More information

FIRE PREVENTION PLAN

FIRE PREVENTION PLAN FIRE PREVENTION PLAN 1 FIRE PREVENTION PLAN OSHA s Fire Prevention Plan regulation, found at 29 CFR 1910.38(b) and 29 CFR 1926.24, requires Northern Clearing, Inc. to have a written fire prevention plan

More information

Section III Hazardous Materials Management

Section III Hazardous Materials Management Section III Hazardous Materials Management This section of the Everyday Hazmat User s Training Guide covers various types of hazardous materials commonly found in the USDA Forest Service. Federal regulations

More information

Fuels Safety Program. Liquid Fuels Handling Code Adoption Document Amendment

Fuels Safety Program. Liquid Fuels Handling Code Adoption Document Amendment Fuels Safety Program Liquid Fuels Handling Code Adoption Document Amendment Ref. No.: FS-207-14 Date: IN THE MATTER OF: Technical Standards and Safety Act 2000, S.O. 2000, c. 16, and Ontario Regulation

More information

STORAGE AND HANDLING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

STORAGE AND HANDLING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS Page 1 of 10 STORAGE AND HANDLING OF These guidelines provide requirements for all University faculty, staff, and students using, handling, or storing flammable and combustible liquids. These requirements

More information

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION Oxford Hills Bus Garage 36 Brown St, Norway, ME Oil Storage Inspection 2/20/14 CONDITIONS OBSERVED Underground Oil Storage: 12,000 gallon underground oil storage tank (split 10,000 gallon diesel/2,000

More information

FUELING AND FUEL STORAGE

FUELING AND FUEL STORAGE FUELING AND FUEL STORAGE BENCHMARK Implement spill prevention measures whenever fuel is handled or stored. Report, minimize, contain and clean up spills that do occur. FUELING BMPS Spills of diesel, oil,

More information

~~~~ Brian L. Harper, M.D., M.P.H. Commissioner of Health. Vito Minei, P.E. Director of Environmental Quality

~~~~ Brian L. Harper, M.D., M.P.H. Commissioner of Health. Vito Minei, P.E. Director of Environmental Quality SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES DIVISION OF ENVIRONMENTAL QUALITY ABOVEGROUND OUTDOOR TANK AND ASSOCIATED PIPING DESIGN STANDARDS ~~~~ Brian L. Harper, M.D., M.P.H. Commissioner of Health

More information

Civil Engineering Sector Labour-Management Health and Safety Committee

Civil Engineering Sector Labour-Management Health and Safety Committee PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION SITES Civil Engineering Sector Labour-Management Health and Safety Committee July 2008 PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION

More information

Flammable Liquids Storage

Flammable Liquids Storage A Health and Safety Guideline for Your Workplace Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario

More information

Performance Standard for Secondary Containment

Performance Standard for Secondary Containment Performance Standard for Secondary Containment For Test Certifiers JULY 2012 PERFORMANCE STANDARD Preface This standard document is one of a series produced by the Environmental Protection Authority (EPA)

More information

The Federal Spill Prevention, Control & Countermeasures (SPCC) Rule Overview

The Federal Spill Prevention, Control & Countermeasures (SPCC) Rule Overview The Federal Spill Prevention, Control & Countermeasures (SPCC) Rule Overview January 2012 Presented by: Annie Macmillan, Stephanie Congo The purpose of the SPCC rule is to prevent discharges of oil into

More information

ALL UST SYSTEMS. MOTOR FUEL, USED OIL, BULK HEATING OIL STORAGE (Federal/State Regulated Systems)

ALL UST SYSTEMS. MOTOR FUEL, USED OIL, BULK HEATING OIL STORAGE (Federal/State Regulated Systems) FACTS ABOUT: UST SYSTEMS COMPLIANCE OUTLINE Maryland Department of the Environment In Maryland, certain UST systems must meet various compliance requirements. The following is a summary of the current

More information

Flammable Liquids 29 CFR 1910.106

Flammable Liquids 29 CFR 1910.106 Flammable Liquids 29 CFR 1910.106 OSHA s Directorate of Training and Education These materials were developed by OSHA s Directorate of Training and Education and are intended to assist employers, workers,

More information

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes FLAMMABLE AND COMBUSTIBLE LIQUIDS OSHA Changes Introduction This module covers the two primary hazards associated with flammable and combustible liquids: explosion and fire. In order to prevent these hazards,

More information

Building Code Clarifications - 7. Fire Resistance

Building Code Clarifications - 7. Fire Resistance Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,

More information

Spill Prevention Control and Countermeasure (SPCC) Regulations Fact Sheet

Spill Prevention Control and Countermeasure (SPCC) Regulations Fact Sheet Spill Prevention Control and Countermeasure (SPCC) Regulations Fact Sheet REGULATORY SUMMARY The Spill Prevention Control and Countermeasure (SPCC) regulations strive to prevent oil from entering navigable

More information

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable

More information

FLAMMABLE AND COMBUSTIBLE LIQUIDS

FLAMMABLE AND COMBUSTIBLE LIQUIDS FLAMMABLE AND COMBUSTIBLE LIQUIDS These guidelines provide requirements for all University faculty, staff, and students using, handling, or storing flammable and combustible liquids. These requirements

More information

How To Safely Handle A Spill

How To Safely Handle A Spill WD DWGB 22 6 2010 Best Management Practices for Fueling and Maintenance of Excavation and Earthmoving Equipment Env Wq 401, Best Management Practices for Groundwater Protection, applies to a variety of

More information

Flammable Liquids Storage

Flammable Liquids Storage A Health and Safety Guideline for Your Workplace Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario

More information

Fixed or Semi-Fixed Fire Protection Systems for Storage Tanks

Fixed or Semi-Fixed Fire Protection Systems for Storage Tanks Fixed or Semi-Fixed Fire Protection Systems for Storage Tanks In the early years of the oil industry, fire in a storage tank was a common occurrence. Virtually all products were stored in cone roof tanks

More information

APPENDIX G Materials Storage and Handling Guidelines

APPENDIX G Materials Storage and Handling Guidelines APPENDIX G Materials Storage and Handling Guidelines 1.0 INTRODUCTION Operations at Austin-Bergstrom International Airport (ABIA) comprise several different industrial activities including aircraft, ground

More information

Spill Control Prevention Plan (SCPP)

Spill Control Prevention Plan (SCPP) Spill Control Prevention Plan (SCPP) FACILITY INFORMATION PLEASE PRINT Facility Name: Mailing Address: Physical address if different: Owner Name: Owner Address: Primary Contact Name: Work Phone Number:

More information

Spill Prevention Control & Countermeasure (SPCC) for Farms

Spill Prevention Control & Countermeasure (SPCC) for Farms Spill Prevention Control & Countermeasure (SPCC) for Farms Ag View FS, Inc. & Marshall-Putman Farm Bureau March 19, 2013 Oil Storage on the Farm Today s Topics: EPA SPCC Regulation Secondary Containment

More information

FLAMMABLE AND COMBUSTIBLE LIQUIDS

FLAMMABLE AND COMBUSTIBLE LIQUIDS CITY OF BLAINE SAFETY SERVICES 10801 Town Square Drive, Blaine MN 55449 Business Phone 763-785-6187 Fax 763-717-2634 FLAMMABLE AND COMBUSTIBLE LIQUIDS Storage, use, dispensing, mixing and handling of flammable

More information

SECTION FC 2706 NON-PRODUCTION CHEMICAL LABORATORIES

SECTION FC 2706 NON-PRODUCTION CHEMICAL LABORATORIES New York City Administrative Code - Title 29 New York City Fire Code SECTION FC 2706 NON-PRODUCTION CHEMICAL LABORATORIES 2706.1 Scope. This section shall govern the storage, handling and use of laboratory

More information

Design of a Fuel Oil Storage Facility

Design of a Fuel Oil Storage Facility Design of a Fuel Oil Storage Facility Background The goal of this project is to design a new, state-of-the-art fuel oil storage facility for the Kanawha Valley Facility, such as the one illustrated in

More information

LIST OF COMMONLY ENCOUNTERED PETROLEUM AND PETROLEUM PRODUCTS 1

LIST OF COMMONLY ENCOUNTERED PETROLEUM AND PETROLEUM PRODUCTS 1 LIST OF COMMONLY ENCOUNTERED AND S 1 Crude Oil 1 Natural Gas 1 Motor Gasoline Aviation Gasoline White Gas Kerosene 2 Jet Fuel Unleaded Gasoline Leaded Gasoline Gasohol Ethanol (E85) AVGAS Kerosene (non-jet

More information

EMERGENCY PETROLEUM SPILL WASTE MANAGEMENT GUIDANCE. Hazardous Materials and Waste Management Division (303) 692-3300

EMERGENCY PETROLEUM SPILL WASTE MANAGEMENT GUIDANCE. Hazardous Materials and Waste Management Division (303) 692-3300 EMERGENCY PETROLEUM SPILL WASTE MANAGEMENT GUIDANCE Hazardous Materials and Waste Management Division (303) 692-3300 First Edition January 2014 This guidance is meant to provide general information to

More information

HAZARDOUS AREA TECHNICAL GUIDE

HAZARDOUS AREA TECHNICAL GUIDE Page 1 HAZARDOUS AREA TECHNICAL GUIDE The Redapt Hazardous Area Technical Guide provides an overview for the design and use of equipment used within potentially explosive atmospheres created by gases,

More information

FLAMMABLE AND COMBUSTIBLE LIQUIDS

FLAMMABLE AND COMBUSTIBLE LIQUIDS CHAPTER 57 FLAMMABLE AND COMBUSTIBLE LIQUIDS SECTION 5701 GENERAL 5701.1 Scope and application. Prevention, control and mitigation of dangerous conditions related to storage, use, dispensing, mixing and

More information

Appendix VIII: Spill Prevention, Control and Countermeasure (SPCC) Plans

Appendix VIII: Spill Prevention, Control and Countermeasure (SPCC) Plans Appendix VIII: Spill Prevention, Control and Countermeasure (SPCC) Plans Background What is a Spill Prevention, Control and Countermeasure (SPCC) Plan? An SPCC plan is a written document that describes

More information

New York State Department of Environmental Conservation 625 Broadway, Albany, NY 12233 www.dec.ny.gov. Environmental Self Audit For Small Businesses

New York State Department of Environmental Conservation 625 Broadway, Albany, NY 12233 www.dec.ny.gov. Environmental Self Audit For Small Businesses New York State Department of Environmental Conservation 625 Broadway, Albany, NY 12233 www.dec.ny.gov Environmental Self Audit For Small Businesses Disclaimer The materials in this document are intended

More information

Antifreeze Solutions in Residential Fire Sprinkler Systems

Antifreeze Solutions in Residential Fire Sprinkler Systems Antifreeze Solutions in Residential Fire Sprinkler Systems The 2013 edition of NFPA 13D, as amended by TIA 13 1, discourages the use of antifreeze solutions within residential fire sprinkler systems unless

More information

Fire & Explosion Risks in Service Stations

Fire & Explosion Risks in Service Stations Fire & Explosion Risks in Service Stations Petrol Vapour Petrol gives off highly flammable vapour even at very low temperatures. Because of the flammability of petrol vapours, service stations carry a

More information

Used Oil Guidance. Tank and Secondary Containment Requirements For Used Oil Processors

Used Oil Guidance. Tank and Secondary Containment Requirements For Used Oil Processors Used Oil Guidance Tank and Secondary Containment Requirements For Used Oil Processors Washington State Department of Ecology Publication Number 05-04-016 November 2005 For more information The Washington

More information

Farm Fuel Tank Safety Guide

Farm Fuel Tank Safety Guide Farm Fuel Tank Safety Guide This brochure is provided by North Dakota Department of Emergency Services, your Local Emergency Planning Committee, and the State Emergency Response Commission along with assistance

More information

Flammable Storage in a Biotech Facility

Flammable Storage in a Biotech Facility Deputy Chief Gerard Mahoney; Chairman 100 Smith Place Cambridge, MA, 02138 (617) 349-4944 Fax: (617) 349-4905 Mailing Address: 491 Broadway Cambridge, MA 02138 Flammable Storage - Intro Date: 12/09/2009

More information

Examples of Flammable Liquid Products Used in the USDA Forest Service

Examples of Flammable Liquid Products Used in the USDA Forest Service FLAMMABLE LIQUID 3 Examples of Flammable Liquid Products Used in the USDA Forest Service Flammable Liquids NFPA Class IA Ether (starting fluid)............................. Flammable Liquids NFPA Class

More information

CHAPTER 62-740 PETROLEUM CONTACT WATER

CHAPTER 62-740 PETROLEUM CONTACT WATER CHAPTER 62-740 PETROLEUM CONTACT WATER 62-740.010 Declaration of Intent (Repealed) 62-740.020 Applicability 62-740.030 Definitions 62-740.040 General 62-740.100 Management Practices for Producers of PCW

More information

Safe Operating Procedure

Safe Operating Procedure Safe Operating Procedure (Revised 3/14) ABOVEGROUND PETROLEUM STORAGE TANKS INTRODUCTION Aboveground storage tanks (ASTs) are used to store petroleum products at several UNL locations. For example, ASTs

More information

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity? A Health and Safety Guideline for Your Workplace What is static electricity? What causes it? How is it hazardous? And, most importantly, how can it be controlled? All of these questions will be answered

More information

Fire Prevention Plan for Flynn Hall 1648 Musketeer Drive

Fire Prevention Plan for Flynn Hall 1648 Musketeer Drive Audit and Risk Management and Xavier Police Fire Prevention Plan for Flynn Hall 1648 Musketeer Drive Xavier University October 12, 2006 Ken Grossman Page 1 10/29/2013 Table of Contents Fire Prevention

More information

The Federal Spill Prevention, Control & Countermeasures (SPCC) Rule Overview

The Federal Spill Prevention, Control & Countermeasures (SPCC) Rule Overview The Federal Spill Prevention, Control & Countermeasures (SPCC) Rule Overview January 2012 Presented by: Annie Macmillan, Stephanie Congo The purpose of the SPCC rule is to prepare and implement a plan

More information

If your campus has. Oil Pollution Prevention Rules (con.) Oil Pollution Prevention Rules (con.)

If your campus has. Oil Pollution Prevention Rules (con.) Oil Pollution Prevention Rules (con.) De-Mystifying the Oil SPCC Rules Presented by: Karen Townsend, P.E. Project Manager Woodard & Curran August 9, 2004 Agenda 1. Oil SPCC Regulatory Background 2. Highlights of 2002 Oil SPCC Amendments 3.

More information

Guide to Certification for Retail Hardware Stores

Guide to Certification for Retail Hardware Stores Guide to Certification for Retail Hardware Stores A Guide for the Person in Charge DECEMBER 2011 TECHNICAL GUIDE 2 Table of contents Table of contents... 2 Preface... 3 Purpose of this publication... 4

More information

KANSAS STORAGE TANK PROGRAM ABOVEGROUND STORAGE TANK OVERVIEW March 2, 2015

KANSAS STORAGE TANK PROGRAM ABOVEGROUND STORAGE TANK OVERVIEW March 2, 2015 KANSAS STORAGE TANK PROGRAM ABOVEGROUND STORAGE TANK OVERVIEW March 2, 2015 http://www.kdheks.gov/tanks/index.html Copies of this document are available at: http://www.kdheks.gov/tanks/download/ast_overview.pdf

More information

NDEP Bureau of Corrective Actions Secondary Containment Regulations Guidance Document April 7, 2010 (Revision)

NDEP Bureau of Corrective Actions Secondary Containment Regulations Guidance Document April 7, 2010 (Revision) NDEP Bureau of Corrective Actions Secondary Containment Regulations Guidance Document April 7, 2010 (Revision) ADOPTED REGULATION OF THE STATE ENVIRONMENTAL COMMISSION LCB File No. R005-08 (Codified in

More information

Standard Operating Procedure

Standard Operating Procedure Standard Operating Procedure FLAMMABLE LIQUIDS This standard operating procedure (SOP) is intended to provide general guidance on how to safely work with flammable liquids. This SOP is generic in nature

More information

Safety Manual Title: Spill Prevention & Response Review Date: 6/1/2014

Safety Manual Title: Spill Prevention & Response Review Date: 6/1/2014 Operation s Purpose The purpose of this plan is to document spill prevention and response requirements. Each Elkhorn Construction, Inc. jobsite will develop a spill prevention and response plan based on

More information

Section A SPCC Plan Implementation Checklist This section of the report addresses compliance with certain requirements of Federal Regulations 40 CFR 112. I. STATUS OF SPCC PLAN (40 CFR 112.3) YES NO A.

More information

MaxCell Technical Manual Design Parameters

MaxCell Technical Manual Design Parameters MaxCell Technical Manual Design Parameters Breaking Strength by Product Style, lbs Product Style Standard MaxCell Fire Resistant MaxCell Test Method 4 Cell 2,750 2,200 ASTM D 5 Bellcore 5 5.. Cell 2,50

More information

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems Page 1 of 5 Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems New Hampshire Department of Environmental Services

More information

FLAMMABLE AND COMBUSTIBLE LIQUIDS

FLAMMABLE AND COMBUSTIBLE LIQUIDS GAP.8.1.0 A Publication of Global Asset Protection Services LLC FLAMMABLE AND COMBUSTIBLE LIQUIDS INTRODUCTION National Fire Protection Association (NFPA) documents describe a level of fire protection

More information

Rule 1146.2 - EMISSIONS OF OXIDES OF NITROGEN FROM LARGE WATER HEATERS AND SMALL BOILERS

Rule 1146.2 - EMISSIONS OF OXIDES OF NITROGEN FROM LARGE WATER HEATERS AND SMALL BOILERS Rule 1146.2 - EMISSIONS OF OXIDES OF NITROGEN FROM LARGE WATER HEATERS AND SMALL BOILERS (a) Purpose and Applicability The purpose of this rule is to reduce NOx emissions from natural gas-fired large (commercial)

More information

LIQUEFIED PETROLEUM GASES

LIQUEFIED PETROLEUM GASES CHAPTER 38 LIQUEFIED PETROLEUM GASES SECTION 3801 GENERAL 3801.1 Scope. Storage, handling and transportation of liquefied petroleum gas (LP-gas) and the installation of LP-gas equipment pertinent to systems

More information

The Original and Patented Stackable Poly Tanks. When You Want to Beat the Drum!

The Original and Patented Stackable Poly Tanks. When You Want to Beat the Drum! The Original and Patented Stackable Poly Tanks When You Want to Beat the Drum! A TOTE A LUBE STORAGE & DISPENSING SYSTEM IS A LOW COST INVESTMENT THAT PAYS HIGH DIVIDENDS IN TIME SAVED, EFFICIENT USE OF

More information

Vehicle Maintenance Facilities Requirements for CNG and LNG Vehicles

Vehicle Maintenance Facilities Requirements for CNG and LNG Vehicles Vehicle Maintenance Facilities Requirements for CNG and LNG Vehicles Presented by: Leo Thomason Executive Director Natural Gas Vehicle Institute (NGVi) at NFPA Conference and Expo, June 11, 2014 Leo Thomason

More information