Selection Guide for Mechanical Thermometers

Size: px
Start display at page:

Download "Selection Guide for Mechanical Thermometers"

Transcription

1 Selection Guide for Mechanical Thermometers SCOPE The purpose of this article is to outline three popular classes of Self Powered mechanical thermometers. Having knowledge of thermometer selection criteria is important for proper use and value to the user. Every application presents a unique set of circumstances that need to be considered. Rangeability, the range span and the resolution in the use range, is an important factor for choosing the instrument that will have the required accuracy. Metric ( C), English ( F), or dual units of measure are important for the familiarity of the end users. Over range, and storage temperature capability are of considerable concern for protection against damage and for the long life use that these thermometers are expected to have. Measurement accuracy is most important and can be stated in a variety of ways according to the type and class of thermometer. Environmental conditions, such as ambient temperature and outdoor exposure, need to be taken into account when choosing a type and style of thermometer casing. Thermowells are available in a variety of materials and sizes and process connections; a proper fit of the thermowell to the thermometer stem is important and is shown for each classification of thermometer. External, internal or non-resetable adjustments may be required for field adjustment; each type of thermometer has a field adjustment feature that is unique. Reliance on self-powered thermometers to perform their function is enhanced with proper selection knowledge. More detailed information on the thermometers described can be found in "Temperature Measurements" ASME/ANSI PTC 19.3, Performance Test Codes, Part 3. SELF POWERED THERMOMETERS An instrument, which generates movement of a column of liquid or a pointer across a scale, graduated to define a temperature range. The energy to move this column or pointer is derived from thermal energy delivered via temperature differential to the thermometer bulb, without any outside power source. There are three general types of self-powered thermometers: LIQUID-IN GLASS 1 - Liquid in-glass 2 - Bimetallic Actuated 3 - Filled System A Liquid-in-glass Thermometer is one consisting of a thin-walled glass bulb attached to a glass capillary stem closed at the opposite end, with the bulb and a portion of the stem filled with an expansive liquid, the remaining part of the stem being filled with an inert gas. Associated with the stem is a scale in temperature degrees so arranged that when calibrated the reading corresponding to the end of the liquid column indicates the temperature of the bulb. The 3/3/06 Page 1 of 1 This sheet is reviewed periodically and may be updated. Visit for the latest version.

2 operation of a liquid-in-glass thermometer depends upon the coefficient of expansion of the liquid. As a consequence, an increase in the temperature of the bulb causes liquid to be expelled from the bulb, resulting in a rise in position of the end of the liquid column. ETCHED STEM LABORATORY THERMOMETER As the name suggests, the scale is marked directly on the glass stem by etching. The etched stem marks are made legible by filling with a pigment material. Etched stem thermometers are manufactured for total immersion, or partial immersion. An emersion line is etched to the thermometer tube to indicate the immersion depth on a partial immersion thermometer. Full immersion thermometers are considered the most accurate because the stem is at the same temperature as the bulb; it is necessary, however, to have the depth of the bath to include the column of the thermometer. Etched stem thermometers are used for direct immersion into a liquid. A series of etched stem thermometers called ASTM thermometers are made in strict accordance to rigid specifications of American Society for Testing Materials Standard E1-03, available in 110 versions of sizes and ranges, extreme precision with sub divisions as small as 1/20 th of a degree are available. When cased in a metal armor with a cut out to view the scale etched stem thermometers can be used to measure temperature of sand, powder, liquid asphalt and similar materials. High precision thermometers of this type are made with mercury as the expansion liquid, other liquids are now available that are non-toxic and environmentally compatible, where this is a concern an MSDS data sheet should be requested from the manufacturer. INDUSTRIAL TYPE THERMOMETERS In this type thermometer the glass bulb and a portion of the glass stem are enclosed in a metal tube, while the glass scale section is contained in an attached metal case. The temperature scale is printed on metal plates fastened to the inside of the case; the scale attachment allows a limited vertical adjustment of the scale for field calibration offset. The case opening is closed by a glass or plastic viewing window. Industrial Thermometers are available in a variety of case sizes, stem lengths and case-stem angles. The bulb chamber, or sensitive portion may be immersed directly in the medium whose temperature is being measured, or more common it may be inserted in a well (separable socket), which in turn is threaded into a pipeline, tank or other vessel. The extension of the bulb assembly incorporates a threaded swivel nut connection. It is thru this connection, the thermometer is mounted to the well (separable socket). Metal to metal contact between the tapered bore of the thermo-well, and the tapered sensitive portion of the bulb chamber, provides the thermal path directly to the sensing portion and a rapid response to temperature changes in the process being measured. Union bushings and air duct flange connections are also available as an alternative means of mounting. 3/3/06 Page 2 of 2 This sheet is reviewed periodically and may be updated. Visit for the latest version.

3 Industrial Thermometers are available in case stem angles of 180º or straight, the 90º back angle, 90º right and left side angles, and various oblique angles. The step angle allows the connection to various pipe connections with the reading portion in an upright vertical position. An adjustable angle form can be positioned to assume all of the case stem angles and has become by far the most popular type. This field position adjustment is a valuable aid when installing the thermometer to the equipment. The most common case sizes are 7", and 9. A 6" case thermometer is available for small pipelines, and other equipment where space is somewhat limited. Stem construction, wells (separable sockets) and other fittings have their distinct thread and sizing, different from the 7" and 9 size. 6" case thermometers have similar case angles, but are not available in the adjustable angle configuration. Industrial Thermometers historically used Mercury as the actuating medium; the modern Industrial Glass thermometer uses an organic liquid as the fill media that is responsive to temperature change. With Mercury actuated Industrial Thermometers the limits for temperature ranges are as follows: Adjustable Angle: -40ºF thru 750 F. All other fixed case forms: -40ºF thru 1100ºF With the Organic liquid ranges limits are from -300ºF thru 550ºF. Most applications for Industrial glass thermometers are within 40 F to 550 F. Celsius and dual scales are readily available. See Alert Bulletin published by Fluid Controls Institute regarding mercury. A copy is available on the Fluid Control Institute s website: Please refer to ASME PTC 19.3 for additional details. BIMETALLIC ACTUATED THERMOMETER An analog, dial type, device utilizing a bimetal element which senses temperature and indicates it by means of a pointer moving over a graduated scale. Fixing one end of a bimetallic element and attaching a shaft and pointer to the other achieve a rotational motion of the pointer with temperature. The bimetallic element is a strip of dissimilar metals bonded together, and coiled in the form of a helix. The rotational motion of the bimetal helix depends upon the difference in thermal expansion of the two metals. See Illustrations. 3/3/06 Page 3 of 3 This sheet is reviewed periodically and may be updated. Visit for the latest version.

4 LABORATORY OR TEST TYPE BIMETALIC THERMOMETER Tech Sheet #I 308 These thermometers are characterized by the absence of threaded connections, case sizes ranging from 1" to 2-1/2", and stem diameters from 1/8" to 1/4". Standard stem lengths are 5" or 8". Temperature ranges for the laboratory thermometer are -40 F thru 550 F. INDUSTRIAL TYPE BIMETAL THERMOMETER Standard case /dial sizes are 2, 3 and 5 diameter, consider installation space limitations and readability when choosing the size. There are three case connections adjustable angle, rear/back and lower/bottom; all have stainless steel cases and process connections. The case style can have an external reset screw on it so it can be recalibrated in the field or tamper proof which has no adjustment. Threaded connections are generally ¼ NPT for 2 dials and ½ NPT 3 & 5 dials. See Illustrations. Such connection is welded or brazed to the case and to the top of the stem. The diameter of the stem is 1/4". Standard stem lengths are 21/2, 4, 6, 9, 12, 15, 18 & 24. Longer stem lengths are available. This thermometer is available dry or liquid filled, for very severe applications special high shock constructions are made. Thermo-wells are the major accessories for bimetallic thermometers. Where pressure, velocity, corrosion, or erosion indicates the need for greater protection of the thermometer stem, wells should be used, where process condition warrants it. Temperature ranges for the bimetallic Industrial thermometer are -80ºF thru 1000ºF. (Continuous service up to 800ºF with intermittent service from 800ºF to 1000ºF). Liquid filled bimetallic industrial thermometers are available in ranges from -20 to 550ºF. Refer to ASME B40.3 and ASME PTC 19.3 for further details. FILLED SYSTEM THERMOMETERS Filled system thermometers are suitable for a wide variety of applications and are therefore offered in various categories called classes. Filled system thermometers are the only selfpowered temperature instruments that can be produced for direct mounting to equipment or as a remote mounting, with the sensing element (bulb) mounted up to 100 feet away from the case. The common elements are they all use a bulb which is completely or partially filled; a connecting tubing or capillary; an elastic element which may be in the shape of a "C", helical, spiral, or other form; and a movement that converts elastic element motion to a rotary pointer. If the elastic element is a direct drive spiral, or helix, a movement is not used. Case sizes for filled system thermometers are offered from 2" Diameter thru 81/2" Diameter in a variety of materials and mounting configurations. Sensing bulbs are available in different styles and sizes, bulbs with a union connection mount directly into a process or thermowell, plain bulbs for use in open tanks 3/3/06 Page 4 of 4 This sheet is reviewed periodically and may be updated. Visit for the latest version.

5 or air and special air bulbs that have a quick temperature response and can measure the average temperature across an air duct. See Illustration. CLASSIFICATION SUMMARY CLASS Filling Range Limits 1 Organic Liquid -100/750ºF - 70/400ºC 2 Vapor -40/450ºF - 40/230ºC 3 Gas -320/1200ºF - 200/650ºC 4 Gas w/adsorbent -320/1200ºF - 200/650ºC 5 Mercury -40/1000ºF - 40/540ºC 6 Non-organic liquid -40/300ºF - 40/150ºC In addition to the basic class designations, there are sub classifications that consider compensation to correct the effects of ambient temperature changes on the elastic element (case compensation) or the effect on the entire length of the capillary. Consideration should be given to the following: *Accuracy required *Case size and means of mounting *Process compatibility *Installation into process *Operating Range Please refer to ASME PTC 19.3 for addition details 3/3/06 Page 5 of 5 This sheet is reviewed periodically and may be updated. Visit for the latest version.

6 REFERENCED SPECIFICATIONS AND PERFORMANCE TEST CODES Tech Sheet #I 308 All ASME (American Society of Mechanical Engineers) standards noted refer to temperature measuring instruments described in this article. SELECTION GUIDE: ETCHED STEM THERMOMETERS (Options) Length: pocket 6, 12,16,18,and 24 Immersion: Partial or full Range: select between 150F and 750F or specify C Accuracy: sub divisions of 5, 2, 1,1/2,1/5, 1/10, or 1/20 Fill Media: Mercury, Spirit, or Environmental safe liquid Accessories: Open Face Armor, Solid Armor, Certificate of accuracy (Example): 12, 3 immersion, 30/0/120F, 1 sub divisions, mercury, with armor SELECTION GUIDE: INDUSTRIAL TYPE THERMOMETERS (Options) Scale/ Case Size: 7, 9 Stem Connection: Back, Bottom, or Adjustable Temperature Range: -40F to 750F Stem Length: 3.5, 6, 9, 12 Thread Size: 1 ¼ - 18 swivel nut (industry standard) or air duct flange Fill Media: Mercury, Spirit, Environmental safe liquid Thermowell (if required): to fit stem length with NPT at hex or on thermowell neck supplied as standard in Brass, optional Stainless Steel or Steel (Example): 9, Adjustable form, 30/240F, standard connection, Environmental safe liquid, 3.5 well ¾ NPT Brass SELECTION GUIDE BIMETALLIC THERMOMETERS (Options) Type: Test or Industrial Dial/Case Size: Test type 1 or 1 ¾ Industrial Type 2, 3 or 5 diameter 3/3/06 Page 6 of 6 This sheet is reviewed periodically and may be updated. Visit for the latest version.

7 Connection Location: Test type Back connected Industrial Back, Bottom or Adjustable Connection Size: Industrial Type ½ NPT standard External Reset Adjustment: With reset or without reset Stem Length: Test Type 5 or 8 Industrial Type 2.5, 4, 6, 9, 12 Stem Diameter: Test Type.150 Industrial Type ¼ Range: Specify from standard ranges between 80 to 100F or equivalent C or dual scale Accuracy: 1% of scale range Thermowell (if required) To fit stem length Brass or Stainless steel with ½ NPT, ¾ NPT, 1 NPT at the hex or with lagging extension neck (Example): 5 Industrial Type, adjustable form, ½ NPT, with reset screw, 4 stem X ¼ diameter, range 0/250 F, nominal 4 SS well ¾ NPT SELECTION GUIDE FILLED SYSTEM THERMOMETERS (Options) Dial/Case Size: 2, 2 ½, 3 ½, 4 ½, 6 and 8 ½ Case Material: Stainless Steel (all sizes), Die cast Aluminum (4 ½ & 6 ), Phenolic (4 ½, 6 ) Mounting Style: Remote Mount (Front Flange, U-clamp, or Back Flange), Direct Mount (Adjustable with thermowell or Union connection) Range: Depends upon classification available in F, C, or dual scale Accuracy: 1% or 1 scale division Capillary: Remote Type-1 to 100 ft copper, stainless steel, braded copper, armored stainless steel Connection: Includes fitting for thermowell or Union, plain no fitting Sensing Bulb: Depends upon class ¼, 3/8, 7/16, ½, 9/16 and ¾ Fill Media: Depends upon classification Thermowell (if required): Size/style to fit sensing bulb, Brass and stainless steel available (Example): 4 ½ case, Stainless Steel case, Remote with Back Flange, Range 50/750 F & 0/400ºC dual scale, 1% full scale accuracy, 20ft capillary, union connection for, 6 SS thermowell with ½ NPT, 3/8 dia X 3 sensing bulb, Enhanced Gas filled (class 4) 3/3/06 Page 7 of 7 This sheet is reviewed periodically and may be updated. Visit for the latest version.

8 3/3/06 Page 8 of 8 This sheet is reviewed periodically and may be updated. Visit for the latest version.

9 3/3/06 Page 9 of 9 This sheet is reviewed periodically and may be updated. Visit for the latest version.

10 Industrial Type Glass Thermometer 3/3/06 Page 10 of 10 This sheet is reviewed periodically and may be updated. Visit for the latest version.

11 3/3/06 Page 11 of 11 This sheet is reviewed periodically and may be updated. Visit for the latest version.

12 INSTRUMENT SECTION MEMBERS and WEBSITES AMETEK, U. S. GAUGE DIVISION BURKERT FLUID CONTROL SYSTEMS MID-WEST INSTRUMENT MOELLER INSTRUMENT CO., INC. NOSHOK, INC. ORANGE RESEARCH THUEMLING INSTRUMENT GROUP, INC. TREND INSTRUMENTS INC. WEISS INSTRUMENTS, INC. 3/3/06 Page 12 of 12 This sheet is reviewed periodically and may be updated. Visit for the latest version.

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE www.winters.com MANUFACTURER OF INDUSTRIAL INSTRUMENTATION Bi-Metal Thermometers Bi-Metal Thermometers Winters bi-metal thermometers are direct sensing

More information

Many Products...One Source

Many Products...One Source PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K

More information

REGULATORS 175/153 Series

REGULATORS 175/153 Series 175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed

More information

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories Commercial / HVAC / Plumbing Specification Guide For Pressure & Temperature Instruments & Related Accessories Prepared for Consultant, Design & Specification Engineers Gauges Contractor Gauge (PCT, PCT-LF)

More information

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION 220519 - THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION 220519 - THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

A99B Series Temperature Sensors

A99B Series Temperature Sensors FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

B-Series Temperature Switches

B-Series Temperature Switches FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment

More information

79 GAUGE / THERMOMETER H N O

79 GAUGE / THERMOMETER H N O 79 GAUGE / TERMMETER plastic-housing 80 A 100 - D 40 Centre back entry and are not aggressive to copper alloys. Design: E 837-1. Case: black plastic. Dial: white plastic. Window: clear plastic. Pressure

More information

The Unique Accelabar Flow Meter

The Unique Accelabar Flow Meter The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD HVAC/R GAS TEST GAUGE Hex or Bell Type mounting 5 to00 Psi pressure ranges Steel case and brass internals Use to pressure test all new gas installations for leaks and passing inspection codes. After installing

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

Bimetal thermometer Model 52, industrial series

Bimetal thermometer Model 52, industrial series Mechanical temperature measurement Bimetal thermometer Model 52, industrial series WIKA data sheet TM 52.01 for further approvals see page 6 Applications A wide range of applications in machine building,

More information

Bimetal Operating Principle

Bimetal Operating Principle BI-METAL THERMOMETERS Mechanical Temperature > Bimetal Thermometers > Bimetal Operating Principle Bimetal Operating Principle The temperature is measured with a bimetal system inside the thermometer stem.

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

Thermometer in stainless steel with capillary and switch contacts

Thermometer in stainless steel with capillary and switch contacts Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy

More information

SOLFRUNT Pressure Gauges and Other Products for the Process Industries

SOLFRUNT Pressure Gauges and Other Products for the Process Industries A1 SOLFRUNT Pressure Gauges and Other Products for the Process Industries AMETEK s line of high quality process gauges are specifically designed to meet the demanding needs of the chemical and petroleum

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

BIMETAL THERMOMETERS Universal Mount All Star Adjustable Union All Pro Replaceable Element Slip-Fit 3A Sanitary Surface Thermometers Thermowells

BIMETAL THERMOMETERS Universal Mount All Star Adjustable Union All Pro Replaceable Element Slip-Fit 3A Sanitary Surface Thermometers Thermowells BIMETAL THERMOMETERS Universal Mount All Star Adjustable Union All Pro Replaceable Element Slip-Fit 3A Sanitary Surface Thermowells 316SS IP67 All Star now in 316SS with IP67 www.palmerwahl.com PW1120

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

15. Liquid-in-Glass Thermometry

15. Liquid-in-Glass Thermometry 123 15. Liquid-in-Glass Thermometry Even though the liquid-in-glass thermometer is used much less frequently today than formerly, it is still a very commonly used device. Although it is normally an instrument

More information

ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.

ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16. ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.4-1998 - Cast Iron Threaded Fittings ASME/ANSI B16.5-1996 - Pipe

More information

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial sect. 05 9600 rev. 206/08/0 Pressure Gage and Swichgage Instruments OPL Series 4-/2 in. (4mm) Diameter Dial The OPL-series pressure Swichgage instruments are combination pressure indicating gages with

More information

Screw Plug Immersion Heaters

Screw Plug Immersion Heaters Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters

More information

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems APPLICATION AID SAA20 Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems Duct Air page 4 Thermal-Ribbon pages 6-7 Room Air Compact Room Air page

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

Boilers Compressors Chillers Pipe Systems. HVAC & Refrigeration Applications Pressure and Temperature Measurement

Boilers Compressors Chillers Pipe Systems. HVAC & Refrigeration Applications Pressure and Temperature Measurement Boilers Compressors Chillers Pipe Systems HVAC & Refrigeration Applications Pressure and Temperature Measurement R Mechanical Pressure Refrigeration Gauge WIKA s type 111.11RF 2½ gauges, which have an

More information

Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems

Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems The measurement of temperature is critical in the determination of the true volume of product in a hydrocarbon

More information

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures

More information

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below: Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees

More information

Self-operated Temperature Regulators Temperature Regulator Type 1u

Self-operated Temperature Regulators Temperature Regulator Type 1u Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2 Instruction Manual Dew Point Tester The CVS Dew Point Tester is a chilled mirror apparatus, which operates by attaining the conditions necessary by the definition of dew point. When a gas is cooled out

More information

Model 43AP Pneumatic Controller, Style B

Model 43AP Pneumatic Controller, Style B Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set

More information

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose: PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Self-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F

Self-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F Self-operated Temperature Regulators Type 1 to Type 9 PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F Edition April 2012 Information Sheet T 2010 EN Self-operated

More information

Temperature Regulators

Temperature Regulators Direct-Operated Temperature www.watsonmcdaniel.com 428 Jones Boulevard Limerick Airport Business Center Pottstown PA 19464 Tel: 610-495-5131 265 W91 Non-Indicating Indicating - Dial Thermometer Description

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for

More information

Baumann 81000 Mikroseal Control Valve

Baumann 81000 Mikroseal Control Valve Product Bulletin D103340X012 Baumann 81000 Mikroseal Control Valve The Baumann 81000 Mikroseal control valve (figures 1 and 2) is excellent for throttling of liquid or gaseous media, particularly where

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family

More information

Hose Clamps & Fittings

Hose Clamps & Fittings All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw

More information

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

Commercial Gas Cooking Thermostats

Commercial Gas Cooking Thermostats BJWA Series Commercial Gas Thermostat A223 Commercial Gas Cooking Thermostats Designed specifically for heavy-duty commercial oven and griddle applications Hi-Temp thermostat with steel bulb and capillary

More information

THERMOCOUPLES GENERAL DESIGN AND SELECTION THERMOCOUPLE STANDARD

THERMOCOUPLES GENERAL DESIGN AND SELECTION THERMOCOUPLE STANDARD THERMOCOUPLES GENERAL Straight Thermocouples Straight thermocouple with metal and ceramic protecting tubes are widely used in a variety of processes between 200 C and 2320 C The maximum operating temperatures

More information

SITRANS F flowmeters SITRANS F M

SITRANS F flowmeters SITRANS F M Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update

More information

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS THERMOMETERS BIMETA THERMOMETERS (DIN 1 1 - PART 2) TYPE: MBT 7 2 4 8 1 12 C APPICATION This thermometer is designed for indication of oil temperature in both transformers with epansion conservator or

More information

Baumann 87000 Flexsleev Sanitary Control Valve

Baumann 87000 Flexsleev Sanitary Control Valve Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

PTFE Slide Bearings 04/10 149

PTFE Slide Bearings 04/10 149 04/10 149 1.0 GENERAL INFORMATION In a wide range of applications, PTFE Slide bearings are superior to conventional expansion plates, rollers and rocker arm type supports. They support petrochemical plant,

More information

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide: LO TORC Plug Valve The high value, dependable performance, and low maintenance requirements of Halliburton Lo Torc valves can help reduce overall operating costs and help cut downtime. These features have

More information

Introducing VE Thermowell

Introducing VE Thermowell Thermowell Introducing VE Thermowell Finally we can deliver the best possible performance AND safety, with total confidence in both. A complex and meticulously researched and engineered product, providing

More information

TEL-TRU MANUFACTURING COMPANY BIMETAL THERMOMETERS

TEL-TRU MANUFACTURING COMPANY BIMETAL THERMOMETERS TEL-TRU MANUFACTURING COMPANY BIMETAL THERMOMETERS www.teltru.com Tel-Tru Manufacturing Company We manufacture thermometers but we sell service, reliability, product quality and performance, and our experience

More information

BB-18 Black Body High Vacuum System Technical Description

BB-18 Black Body High Vacuum System Technical Description BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The

More information

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors s Control Analysis Fabrication A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors Eductors Ensure Thorough Mixing to Improve Product Quality and Reduce Maintenance Time Tank mixing eductors

More information

Submersion/Insertion Toroidal Sensor

Submersion/Insertion Toroidal Sensor Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS

More information

Portable digital microprocessor thermometers with interchangeable probes

Portable digital microprocessor thermometers with interchangeable probes JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

Part I - Installation

Part I - Installation 400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read

More information

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as

More information

FLASH TANK ECONOMIZER PRODUCT GUIDE

FLASH TANK ECONOMIZER PRODUCT GUIDE FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.

More information

Lathe Milling Attachment

Lathe Milling Attachment Lathe Milling Attachment By L C. MASON BY CLEVERLY stacking cold-rolled flat stock together, T-slots and slide for this lathe milling attachment are made without costly machinery. In fact, only two tools,

More information

Item Number Description Type of Gauge Size in " Price

Item Number Description Type of Gauge Size in  Price FARIA Euro Perimeter lighted black dial with bold white graphics, black aluminum bezel, contoured white pointer and flat fog resistant lens EURO Item Number Description Type of Gauge Size in " Price 32805

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

Temperature Calibration; Depths of Immersion

Temperature Calibration; Depths of Immersion Temperature Calibration; epths of Immersion Author: John P. Tavener Company Isothermal Technology Limited, Pine Grove, Southport, England Abstract Of all the sources of errors and uncertainties in thermal

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,

More information

Heat Pipe Selection Revision 12/04/2001

Heat Pipe Selection Revision 12/04/2001 Heat Pipe Selection Revision 12/04/2001 Heat pipes are being used very often in particular applications when conventional cooling methods are not suitable. Once the need for heat pipe arises, the most

More information

Laminar Flow Elements

Laminar Flow Elements Laminar Flow Elements Meriam Laminar Flow Elements (LFEs) are excellent for measuring low gas flow rates from 0.2 SCCM up to 2250 SCFM. They are inherently accurate and repeatable and are calibrated traceable

More information

Die casting Figure M2.3.1

Die casting Figure M2.3.1 Die casting Die casting is a moulding process in which the molten metal is injected under high pressure and velocity into a split mould die. It is also called pressure die casting. The split mould used

More information

Copper and Copper Alloy Tube, Pipe and Fittings

Copper and Copper Alloy Tube, Pipe and Fittings Copper and Copper Alloy Tube, Pipe and Fittings COPPER and COPPER ALLOY TUBE and PIPE Seamless Copper Pipe: Copper pipe is almost pure copper manufactured to the requirements of ASTM B 42 - Standard Specification

More information

Fisher 377 Trip Valve

Fisher 377 Trip Valve 377 Trip Valve Product Bulletin Fisher 377 Trip Valve Fisher 377 pressure sensing trip valves are for control applications where a specific valve/actuator action is required when supply pressure falls

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

Ultrasonic Reference Blocks

Ultrasonic Reference Blocks Ultrasonic Reference Blocks Custom and Standard Test Blocks for Nondestructive Testing Introduction 3 IIW Type 1 Calibration Block 4 Miniature Angle Beam (ROMPAS) Calibration Block 4 Distance Calibration

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

AIR LINE VALVES AND GAUGES

AIR LINE VALVES AND GAUGES AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand

More information

Steam System Best Practices Condensate System Piping

Steam System Best Practices Condensate System Piping Steam System Best Practices Condensate System Piping Summary The best method for improving steam system energy efficiency, reducing chemical costs, and reducing make-up water costs is to return the maximum

More information

RTD Temperature Probe for the Food/Pharmaceutical Industry

RTD Temperature Probe for the Food/Pharmaceutical Industry sales@jumo.co.uk Data Sheet 902810 Page 1/9 RTD Temperature Probe for the Food/Pharmaceutical Industry For temperatures between -50 and +250 C Protection type up to IP69 according to DIN EN 60529 (IP69K

More information

WIKA INSTRUMENT CORPORATION

WIKA INSTRUMENT CORPORATION WIKA INSTRUMENT CORPORATION Instruction Manual GAUGE PRESSURE INDICATOR Series 1500 Series 1000 Series 300 WIKA Instrument Corporation 1000 Wiegand Boulevard Lawrenceville, GA 30043 1-888-945-2872 http://www.wika.com

More information

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description. Worldwide Contacts www.tyco-fire.com Series Multiple Jet Controls DN20, DN25, DN40, and DN50, 2 bar BSPT Inlet & Outlets Threads General Description The TYCO Series Multiple Jet Controls are control valves

More information

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here. COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?

More information

Corrugated Tubular Heat Exchangers

Corrugated Tubular Heat Exchangers Corrugated Tubular Heat Exchangers HEAT EXCHANGERS for the 21st CENTURY Corrugated Tubular Heat Exchangers (CTHE) Corrugated Tube Heat Exchangers are shell and tube heat exchangers which use corrugated

More information

Micro Motion Model D and DL Coriolis Flow and Density Meters

Micro Motion Model D and DL Coriolis Flow and Density Meters Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,

More information

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB PRODUCT DESCRIPTION: BOON EDAM TOMSED MODEL TUT-65TMB STAINLESS STEEL BARCODE SCANNING ELECTRONIC REGISTERING TURNSTILE SCOPE OF OPERATION: A. The TUT-65TMB

More information

Safety at a high level!

Safety at a high level! SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP

More information

RAPID DIAL TEST INDICATORS

RAPID DIAL TEST INDICATORS RAPID DIAL TEST INDICATORS The Verdict Rapid presents the dial face inclined to the workpiece surface ensuring good visual accessibility obviating parallax error. Rapids incorporate a rear swivel spigot

More information

Introduction to vacuum gauges. Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges)

Introduction to vacuum gauges. Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges) Introduction to vacuum gauges Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges) BOURDON Vacuum Gauge The inside of a tube which is bent into a circular

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Pressure calibration equipment

Pressure calibration equipment Pressure calibration equipment Pressure calibration evolution 1925 Westertoren in Amsterdam 30 meter mercury column (±40 bar) 1950 comparison test pump 21 st century Stiko gas driven differential deadweight

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

KEYSTONE. Stainless steel hygienic butterfly valves F250 for imperial tubing F251 for metric tubing

KEYSTONE. Stainless steel hygienic butterfly valves F250 for imperial tubing F251 for metric tubing KEYSTONE Stainless steel hygienic butterfly valves F0 for imperial tubing F for metric tubing Features Keystone technology. Quarter turn operation. Isolation or regulation control. Equal percentage characteristics.

More information

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions The Versatile Differential Pressure Transmitter By David Gunn Honeywell Process Solutions The Versatile Differential Pressure Transmitter 2 Table of Contents Abstract... 3 Pressure Fundamentals... 3 Applications...

More information

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B s/objectives Level B CHEM 6014: Properties and Characteristics of Natural Gases Discuss the pertinent properties and uses of natural gases as they occur in gas processing. 1. Describe the physical properties

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information