1 PCC Air Cooled Process Cooling Chillers From 5kW to 225kW 3 Operating Characteristics R410A as standard R134A high ambient R404A low temperature Industrial Process Cooling Air Conditioning

2 GalxC has evolved and become one of the UK s leading sales and service providers in industrial packaged water chiller, heat pumps and fan coil units. We at GalxC pride ourselves on our professional service, practical expertise and ability to select the most cost effective solution to meet our customer s needs. The latest innovation in Industrial Process Cooling Packaged air cooled water chillers. A reliable, highly efficient, user friendly Industrial Process Cooling Chiller Standard features Integral by-pass Fill and vent tank Internal flow switch Integral 3 bar pump Integral hydraulic tank Auto-adaptive set point Electronic expansion valve Modulating fan speed control User friendly controller Inlet & outlet ball valves, fitted into integral pump 10 Good reasons to opt for the PCC Highly Efficient Servicing Made Easy User-Friendly Controller Optimum Performance Advanced Fluid Control Improved Safety Features All European brand components Correct refrigerant choice, to suit application 2 years Manufacturer Warranty at no additional cost Dedicated Product Support Team throughout the UK

3 Auto Adaptive Advanced microprocessor control Automatically adjusts the unit s set point to the ambient conditions in order to reduce the power consumption Enables lower water volume in the hydraulic circuit Reduces number of compressor start-ups Improved Design Easy Access Servicing and Optimum Performance 1. Fill and Vent Tank 2. Flow Switch 3. Condenser Fans & Safety Fan Guard 4. Integral By-Pass (with external adjustable valve) 5. Hydraulic Pressure Gauge (Rear output panel) 6. Upright Hydraulic Tank 7. Inlet & Outlet Isolating Ball Valves 8. Crank Case Heater 9. High Efficiency Scroll Compressor 10. Hydraulic Pump 11. Filling Point 12. LP & HP Pressure Gauges (Front Outer Panel) 13. Electrical Panel & Controller Selectable options Correct refrigerant for application ~ R410A standard operation ~ R134A high ambient conditions >45 degrees ~ R404A low water temperature <-8 degrees Inverter driven compressor for close control Expansion tank for pressurised system Centrifugal fans (top/front or rear air discharge) 5 Bar Pump EC Brushless Fans Remote Communication

4 GalxC Cooling Services Ltd Unit 3 Lulworth Business Centre Nutwood Way Totton Southampton Hampshire SO40 3WW t: e: f: w: Innovative Cooling Solutions PCC CS sizes PCC005 PCC010 PCC015 PCC020 PCC025 PCC030 PCC035 PCC040 PCC045 PCC050 Water 20/15 C Air 25 C glic0% Cooling Capacity kw Tot. Abs. Power (Fans Incl.) kw Tot. Abs. Current (Fans Incl.) A EER (Incl. Fans,water press drops) Water Flow l/h Pressure drop, water side kpa Available head, standard pump kpa Available head, uprated pump kpa Water 15/10 C Air 25 C glic0% Cooling Capacity kw Tot. Abs. Power (Fans Incl.) kw Tot. Abs. Current (Fans Incl.) A EER (Incl. Fans,water press drops) Water Flow l/h Pressure drop, water side kpa Available head, standard pump kpa Available head, uprated pump kpa Water 12/7 C Air 35 C glic0% Cooling Capacity kw Tot. Abs. Power (Fans Incl.) kw Tot. Abs. Current (Fans Incl.) A EER (Incl. Fans,water press drops) Water Flow l/h Pressure drop, water side kpa Available head, standard pump kpa Available head, uprated pump kpa Water 5/0 C Air 25 C glic25% Cooling Capacity kw Tot. Abs. Power (Fans Incl.) kw Tot. Abs. Current (Fans Incl.) A EER (Incl. Fans,water press drops) Water Flow l/h Pressure drop, water side kpa Available head, standard pump kpa Available head, uprated pump kpa Water 0/-5 C Air 25 C glic25% Cooling Capacity kw Tot. Abs. Power (Fans Incl.) kw Tot. Abs. Current (Fans Incl.) A EER (Incl. Fans,water press drops) Water Flow l/h Pressure drop, water side kpa 11 < Available head, standard pump kpa Available head, uprated pump kpa

5 GalxC Cooling Services Ltd Unit 3 Lulworth Business Centre Nutwood Way Totton Southampton Hampshire SO40 3WW t: e: f: w: Innovative Cooling Solutions PCC CS sizes PCC060 PCC065 PCC070 PCC090 PCC105 PCC120 PCC140 PCC160 PCC180 Water 20/15 C Air 25 C glic0% Cooling Capacity kw Tot. Abs. Power (Fans Incl.) kw Tot. Abs. Current (Fans Incl.) A EER (Incl. Fans,water press drops) Water Flow l/h Pressure drop, water side kpa Available head, standard pump kpa Available head, uprated pump kpa Water 15/10 C Air 25 C glic0% Cooling Capacity kw Tot. Abs. Power (Fans Incl.) kw Tot. Abs. Current (Fans Incl.) A EER (Incl. Fans,water press drops) Water Flow l/h Pressure drop, water side kpa Available head, standard pump kpa Available head, uprated pump kpa Water 12/7 C Air 35 C glic0% Cooling Capacity kw Tot. Abs. Power (Fans Incl.) kw Tot. Abs. Current (Fans Incl.) A EER (Incl. Fans,water press drops) Water Flow l/h Pressure drop, water side kpa Available head, standard pump kpa Available head, uprated pump kpa Water 5/0 C Air 25 C glic25% Cooling Capacity kw Tot. Abs. Power (Fans Incl.) kw Tot. Abs. Current (Fans Incl.) A EER (Incl. Fans,water press drops) Water Flow l/h Pressure drop, water side kpa Available head, standard pump kpa Available head, uprated pump kpa Water 0/-5 C Air 25 C glic25% Cooling Capacity kw Tot. Abs. Power (Fans Incl.) kw Tot. Abs. Current (Fans Incl.) A EER (Incl. Fans,water press drops) Water Flow l/h Pressure drop, water side kpa Available head, standard pump kpa Available head, uprated pump kpa

6

Water Chillers - The range CH and RPW series

Water Chillers - The range CH and RPW series Water Chillers - The range CH and RPW series PIOVAN S.p.A. Cooling Centre 1 (1) Piovan Chiller Range Piovan Spa 03.2004 Modification reserved Water chillers A dedicated Cooling Centre Integration with

More information

Refrigerant R410A. Mini SysAqua DCI. 5.5 to 16.0kW. Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI

Refrigerant R410A. Mini SysAqua DCI. 5.5 to 16.0kW. Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI Refrigerant R4A Mini SysAqua DCI Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI 5.5 to 16.0kW Mini SysAqua DCI 1 Strength Points By introducing the variable speed in our packaged heat pump

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Cool Design for Homes and Offices

Cool Design for Homes and Offices AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners

More information

BTI Light commercial atmospheric water heater

BTI Light commercial atmospheric water heater Light commercial atmospheric water heater BTI - 65/85/100 Atmospheric water heater, primarily intended for light commercial / industrial applications Control, high limit and energy cut-off thermostats

More information

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES

More information

State of the Art Energy Efficient Data Centre Air Conditioning

State of the Art Energy Efficient Data Centre Air Conditioning - White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...

More information

Refrigerated Water Chiller

Refrigerated Water Chiller Refrigerated Water Chiller PCA-200 to 1000 Spare Parts Lists 9829 2107 32 July 2010 Table of Contents PCA-200, 300 Main Parts...2, 3 PCA-400, 500 Main Parts...4, 5 PCA-750, 1000 Main Parts...6 PCA-200,

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

Condensing unit type EPSILON-ECHOS LE Technical information manual

Condensing unit type EPSILON-ECHOS LE Technical information manual Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps

More information

Kälte Klima. Condenserless chillers for indoor installation from 45 kw to 360 kw. Scroll compressors SCLY DE 48

Kälte Klima. Condenserless chillers for indoor installation from 45 kw to 360 kw. Scroll compressors SCLY DE 48 Condenserless chillers for indoor installation from 45 kw to 360 kw Scroll compressors Series: SCLY Leaflet: DE 48 Issue: 03/12 Supersedes: 04/11 Index Identification code Index... pag. 2 Identification

More information

Regency TAFE, SA. An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump. July 2008. Prepared by

Regency TAFE, SA. An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump. July 2008. Prepared by Regency TAFE, SA An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump July 2008 Prepared by Andrew Pang Andrew Pang & Associates Pty Ltd Phone: 0438 188 180 Facsimile: 9331 0898

More information

marine/bespoke split applications

marine/bespoke split applications split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

Direct Fresh Air Free Cooling of Data Centres

Direct Fresh Air Free Cooling of Data Centres White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

SMM. Installation Operation Maintenance

SMM. Installation Operation Maintenance SMM Configuration SMM Module for Scroll Units, H Generation Installation Operation Maintenance 1 0 L80 IM 022 GB SMM Configuration SMM Module for Scroll Units, H generation Foreword These installation,

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

AIRROLLAIR COMPRESSORS 15-20 - 25-30 - 40E

AIRROLLAIR COMPRESSORS 15-20 - 25-30 - 40E AIRROLLAIR COMPRESSORS 15-20 - 25-30 - 40E ROLLAIR 15-40E: INCREASED FLEXIBILITY IN AN EXTENDED RANGE Worthington Creyssensac cares for future generations and is an ISO 14000 certified manufacturing company

More information

Refrigerated Air Dryers. Catalogue

Refrigerated Air Dryers. Catalogue Refrigerated Air Dryers Catalogue GB Why use a refrigerated dryer? Humidity is a component of atmospheric air, which can be found in the compressed air distribution systems and the machines that use the

More information

Drives and motors. A guide to using variable-speed drives and motors in data centres

Drives and motors. A guide to using variable-speed drives and motors in data centres Drives motors A guide to using variable-speed drives motors in data centres The power behind the data Private public businesses, from banks to supermarkets, to telecommunications companies internet providers

More information

Wiring Diagram. Diplomat 400V 3N. www.thermia.com

Wiring Diagram. Diplomat 400V 3N. www.thermia.com www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

Packaged Air Conditioner - Water Cooled Vertical Type Model 25

Packaged Air Conditioner - Water Cooled Vertical Type Model 25 Refrigerant R407C CX Packaged Air Conditioner - Water Cooled Vertical Type Model 25 8.0kW CX 25 1 Product Code Model Power supply Product code CX 25 230V / 1 ~ / 50 Hz 7XU012153 CX 25 CX 25 2 CX 25 General

More information

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R. www.heating.danfoss.com

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R. www.heating.danfoss.com MAKING MODERN LIVING POSSIBLE Wiring Diagram www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29 Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29 A refrigerant retrofit project, involving the conversion of a large Data Room cooling system from R22 to R422D (DuPont

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Aerona Air Source Heat Pumps

Aerona Air Source Heat Pumps ADDENDUM to INSTALLATION INSTRUCTIONS for Aerona Air Source Heat Pumps DOC.87-05/05 Rev.04 March 2013 ATTENTION INSTALLERS - UPDATED INFORMATION! Your Grant Aerona Air Source Heat Pump has a number of

More information

Commercial Hot Water. Make a difference...

Commercial Hot Water. Make a difference... Commercial Hot Water Make a difference... heat S O L A R pumps The Company Quantum Energy Technologies The Quantum story is based on innovation and the quest to harness renewable energy to produce sustainable

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

DATA CENTER SOLUTIONS. For More Information: (866) 787-3271 Sales@PTSdcs.com. Technical Data

DATA CENTER SOLUTIONS. For More Information: (866) 787-3271 Sales@PTSdcs.com. Technical Data DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com Technical Data Contents Overview................................................ 1 Scalable Solution for Critical Environments...................

More information

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009 Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25

More information

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4. AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice

More information

Maintenance for Energy Efficiency

Maintenance for Energy Efficiency Maintenance for Energy Efficiency Institute of Hospital Engineering, Australia (IHEA) Seminar Asset Management & Energy Efficiency Exclusive Trane distributor Australia/New Zealand. The TRANE trade mark

More information

Refrigeration Air Dryers. Catalogue

Refrigeration Air Dryers. Catalogue Refrigeration Air Dryers Catalogue GB Using a dryer is worth it Humidity is a component of atmospheric air, which can be found in our compressed air distribution systems and the machines that use the compressed

More information

Air/water chillers. With plug fans and scroll compressors, for indoor installation Model CGCM Cooling capacity kw CGCM-PRC001A-GB

Air/water chillers. With plug fans and scroll compressors, for indoor installation Model CGCM Cooling capacity kw CGCM-PRC001A-GB Air/water chillers With plug fans and scroll compressors, for indoor installation Model CGCM Cooling capacity 44-315 kw CGCM-PRC001A-GB Contents Technical specifications...4 Options and accessories...9

More information

Air Conditioning. Light Commercial, Commercial and Industrial

Air Conditioning. Light Commercial, Commercial and Industrial Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Air Conditioning Light Commercial, Commercial and Industrial Systemair Trust

More information

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: Test Report issued under the responsibility of: TEST REPORT EHPA-DACH Testing Regulation Supplemental requirements for granting the international quality label for heat pumps Testing of Air/Water Heat

More information

Nirvana. Cycling Refrigerated Dryers

Nirvana. Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:

More information

User manual. 086U6297 Rev. 9 EN

User manual. 086U6297 Rev. 9 EN User manual Atria Atria Duo Atria Duo Optimum Atria Optimum Comfort Diplomat Diplomat Duo Diplomat Duo Optimum Diplomat Duo Optimum G2 Diplomat Optimum Diplomat Optimum G2 086U6297 Rev. 9 EN Thermia Värme

More information

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Hot Water. Heat pump water heaters. Residential and Commercial R410a Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling for Simultaneous Heating and Cooling F. Sustainable Energy Centre, University of South Australia Mawson Lakes Boulevard, Mawson Lakes 5095 AUSTRALIA E-mail: Frank.@UniSA.edu.au Abstract The high efficiency

More information

How to reduce the energy consumption of your air-cooled chillers by up to 25% without breaking the bank? Condenser Fan Pak

How to reduce the energy consumption of your air-cooled chillers by up to 25% without breaking the bank? Condenser Fan Pak How to reduce the energy consumption of your air-cooled chillers by up to 25% without breaking the bank? Condenser Fan Pak Bob Gray HVAC/R Segment Manager Agenda - HVAC/R Market trends - Condenser Fan

More information

100% Oil-Free - Guaranteed

100% Oil-Free - Guaranteed 03 GB 100% Oil-Free - Guaranteed Oil-Free Rotary Screw Compressors Fixed & Regulated Speed (RS) Truly innovative oil-free compressed air technologies D75-D160 and Water Cooled purity that meets the most

More information

Simulation of a small size solar assisted adsorption air conditioning system for residential applications

Simulation of a small size solar assisted adsorption air conditioning system for residential applications Heat Powered Cycles Conference 2009 2009 Simulation of a small size solar assisted adsorption air conditioning system for residential applications Salvatore Vasta, Andrea Frazzica, Gaetano Maggio, Alessio

More information

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) Drives and motors A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) The power behind the data Private and public businesses, from banks to

More information

01 GB. Refrigeration Dryer. High quality compressed air. F-Series. Energy efficient compressed air treatment. 50Hz & 60Hz

01 GB. Refrigeration Dryer. High quality compressed air. F-Series. Energy efficient compressed air treatment. 50Hz & 60Hz 01 GB Refrigeration Dryer High quality compressed air Energy efficient compressed air treatment F-Series 50Hz & 60Hz Energy efficient refrigeration dryers First-class air treatment efficiency For CompAir,

More information

Air-cooled Chillers with High Speed Centrifugal Compressors

Air-cooled Chillers with High Speed Centrifugal Compressors Air-cooled Chillers with High Speed Centrifugal Compressors Model GVAF-X 575-1613 kw Model GVAF-XP 720-1220 kw Model GVAF-XPG 500-1257 kw 1 Trane Sintesis excellent Air-cooled Chillers with High Speed

More information

Midea Commercial Air Conditioner Malfunction Handbook

Midea Commercial Air Conditioner Malfunction Handbook Midea Commercial Air Conditioner Malfunction Handbook May 1, 2008 Customer Service Philosophy of Midea Air Conditioner Service Target: 100% Customer Satisfaction Service Standard: 100% Earnestness Service

More information

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers COMMERCIAL HVAC CHILLER EQUIPMENT Air-Cooled Chillers Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They

More information

Zeta Echos air/water chillers and heat pumps Technical information manual

Zeta Echos air/water chillers and heat pumps Technical information manual Zeta Echos air/water chillers and heat pumps Technical information manual Western Airconditioning B.V. Tel. +31 (0) 33 247 78 00 www.western.nl ZETA ECHOS Water chiller ZETA ECHOS/HP Reversible heat pump

More information

INSTALLATION MANUAL. Address card EKAC10B

INSTALLATION MANUAL. Address card EKAC10B INSTALLATION MANUAL 88 44 µchiller compact 70 64 4a 4b G G0 power supply G G0 power supply 50 5 50 5 4a 4b 5a 5b 4 5a 5b Installation manual READ THIS MANUAL ATTENTIVELY BEFORE STARTING UP THE UNIT. DO

More information

60-150kW. For more information on Airedale visit www.barbourproductsearch.info SmartCool. 0-150kW. > SmartCool. www.airedale.com

60-150kW. For more information on Airedale visit www.barbourproductsearch.info SmartCool. 0-150kW. > SmartCool. www.airedale.com 60-150kW 0-150kW > Next generation precision air conditioning Typical applications > Data centres and computer rooms > Telecommunications and ISP facilities > Clean rooms > Switching stations > Laboratories

More information

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany Life Cycle Costing Analysis of Water-cooled Chillers Chillventa Nuremburg, Germany Spring 2012 Description Life Cycle Cost Analysis is a method of determining and comparing the total costs of investment

More information

Troubleshooting Compressor Faults (Screw compressor equipped chillers.)

Troubleshooting Compressor Faults (Screw compressor equipped chillers.) Troubleshooting Compressor Faults (Screw compressor equipped chillers.) A problem with the compressors operation is displayed with a Compressor Failure Event (alarm) on the FX16 or Carel controller. The

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

AIRAH Refrigeration (in HVAC) Back to Basics. For the First Time

AIRAH Refrigeration (in HVAC) Back to Basics. For the First Time AIRAH Refrigeration (in HVAC) Back to Basics For the First Time Terms of Reference What this session is NOT about Detailed Refrigeration Design Detailed analysis of various Refrigants properties Comparison

More information

GRF Series Non-Cycling Refrigeration Dryers

GRF Series Non-Cycling Refrigeration Dryers GRF Series Non-Cycling Dryers Why Dry Compressed Air Compressed air is a clean, convenient and versatile energy resource ideal for many industrial, commercial and instrument applications. To optimize a

More information

Product Data. Features/Benefits. AquaForce 30XA080-501 Air-Cooled Liquid Chillers. 80 to 500 Nominal Tons (265 to 1740 Nominal kw)

Product Data. Features/Benefits. AquaForce 30XA080-501 Air-Cooled Liquid Chillers. 80 to 500 Nominal Tons (265 to 1740 Nominal kw) Product Data AquaForce 080-501 Air-Cooled Liquid Chillers 80 to 500 Nominal Tons (265 to 1740 Nominal kw) a30-4024 Well exceeds ASHRAE 90.1 Standards. AquaForce chillers were designed from the ground up

More information

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

Advances in Gas Cooler Design and the New Gas Cooler Product Selector Advances in Gas Cooler Design and the New Gas Cooler Product Selector Simon Jones Engineering Manager Sean Armitage Sales Manager Introduction GEA Searle Over 90 years experience in the design and manufacture

More information

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT UP TO 15 SEER Performance MINI-SPLIT SYSTEM UNITS AIR CONDITIONING AND HEAT PUMPS COMPLETE ROOM COMFORT WITH EASY-TO-USE REMOTE CONTROL HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT The Goodman brand offers

More information

Octopus for a sustainable future

Octopus for a sustainable future AN ENVIRONMENTALLY FRIENDLY HEAT PUMP - TODAY AND TOMORROW - Octopus has developed and produced heat pumps since 1981 and has, through many years development, taken forward the best possible solution for

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................

More information

Time to Rethink Heating

Time to Rethink Heating your comfort. our world. Time to Rethink Heating Daikin Altherma Hybrid heat pump Presented by Stuart Tandy Contents 1. Introducing Daikin 2. The time is right for hybrid 3. Rethink heating 4. How hybrid

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

Application Engineering

Application Engineering Application Engineering February 2012 Digital Capacity Control for Copeland Scroll Refrigeration Compressors INDEX Page 1. Introduction... 1 2. Theory of Operation... 1 3. Nomenclature... 1 4. Digital

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

Use, installation and instruction manual

Use, installation and instruction manual MU 5 44 kw Manual M14 Issue 02.99 Replaces 09.96 Use, installation and instruction manual Water chillers Water/water Hermetic scroll packaged compressors ISO 9001 Cert. N. 0603 TECHNICAL DATA MU SERIES

More information

Chapter 4.9: HVAC System

Chapter 4.9: HVAC System Chapter 4.9: HVAC System Short type questions 1. Define tons of refrigeration?. One ton of refrigeration is the amount of cooling obtained by one ton of ice melting in one day. It is equivalent to kcal/h,

More information

AFRICAN DEVELOPMENT BANK, NIGERIA FIELD OFFICE, ABUJA, NIGERIA. LOT 2: VOL 4-2 MECHANICAL (HVAC SERVICES) DRAWINGS MAY 2013

AFRICAN DEVELOPMENT BANK, NIGERIA FIELD OFFICE, ABUJA, NIGERIA. LOT 2: VOL 4-2 MECHANICAL (HVAC SERVICES) DRAWINGS MAY 2013 www.interstatearchitects.com AFRICAN DEVELOPMENT BANK, NIGERIA FIELD OFFICE, ABUJA, NIGERIA. LOT 2: VOL 4-2 MECHANICAL (HVAC SERVICES) DRAWINGS Lagos: 45 M/Muhammed Int/Airport Road, Tinuose House,Ajao

More information

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the specifier in correctly specifying Mechanical System Testing

More information

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro + MAKING MODERN LIVING POSSIBLE User Guide DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro + www.heating.danfoss.com The English language

More information

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT 48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED

More information

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle

More information

Cold Logik. ColdLogik Water Cooled Cabinet Solution. Reduce Your Cooling Energy Consumption. Potential Savings In Excess of 60%

Cold Logik. ColdLogik Water Cooled Cabinet Solution. Reduce Your Cooling Energy Consumption. Potential Savings In Excess of 60% 1 ColdLogik Water Cooled Cabinet Solution Reduce Your Cooling Energy Consumption Potential Savings In Excess of 60% CL20 Rear Door Heat Exchanger RDHx RDHx Principle Fitted to the rear of the cabinet the

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

Heat Pump Applications

Heat Pump Applications Heat Pump Applications For Rebel Commercial Rooftop Systems Rebel Advantages Rebel Is Much Better Than Competitive Heat Pumps Optional variable volume cooling Excellent energy savings Why install a unit

More information

Split units TH with hermetic compressors

Split units TH with hermetic compressors Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

ERROR CODE LISTING COMMERCIAL SPLIT SYSTEMS ELECTRIC VRF GAS DRIVEN VRF HEATING SOLUTIONS. SANYO Air Conditioners. The natural choice.

ERROR CODE LISTING COMMERCIAL SPLIT SYSTEMS ELECTRIC VRF GAS DRIVEN VRF HEATING SOLUTIONS. SANYO Air Conditioners. The natural choice. ERROR CODE LISTING COMMERCIAL SPLIT SYSTEMS ELECTRIC VRF GAS DRIVEN VRF HEATING SOLUTIONS SANYO Air Conditioners. The natural choice. A CODES GHP ENGINE ISSUES A01 GHP - Engine oil pressure fault A02 A03

More information

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

POLICY BULLETIN Tecumseh Compressor Company Compressor Group to Bulk Milk Coolers and Other System Page 1 of 5 Overall reliability can be enhanced if there exists a complete understanding of the features, system design, installation requirements, processing, charging

More information

MANUAL. for installation and start up of cooling hydraulic module HMC30 MkI

MANUAL. for installation and start up of cooling hydraulic module HMC30 MkI MANUAL for installation and start up of cooling hydraulic module HMC30 MkI IM HMC30MkI EN 02 2014 Table of Contents General information Main parts of hydraulic module........3 Overall and mounting dimensions..4

More information

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump. English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation... 3 3.2 The user interface

More information

User manual. Solid (FR 98,),

User manual. Solid (FR 98,), User manual Solid (FR 98,), If these instructions are not followed during installation and service, Thermia Värme ABliability according to the applicable warranty is not binding. Thermia Värme AB retains

More information

EHDC. Cooling system for Data Center and server cabinets.

EHDC. Cooling system for Data Center and server cabinets. EHDC Cooling system for Data Center and server cabinets. EHDC PEN LP EHDC L is a High Density Cooling module for an pen Loop configuration. It is ideally installed with Enoc Systems cold corridor containment

More information

AE21-1319 R6 December 2013. Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE21-1319 R6

AE21-1319 R6 December 2013. Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE21-1319 R6 AE21-1319 R6 December 2013 Digital Capacity Control for Copeland Scroll Refrigeration Compressors TABLE OF CONTENTS Section Page Section Page Safety Safety Instructions...2 Safety Icon Explanation...2

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences

More information