Expansion Vessels. 16 Product overview 2013 We reserve the right to change designs and technical specifications of our products.

Size: px
Start display at page:

Download "Expansion Vessels. 16 Product overview 2013 We reserve the right to change designs and technical specifications of our products."

Transcription

1 . Expansion Vessels Flamco produces a comprehensive range of diaphragm expansion vessels. Both the steel vessel and the diaphragm are of the highest quality. They are compliant with all prevailing European standards and carry the CE mark of conformity. Flamco vessels are available for both potable, chilled and heated water systems in sizes ranging from 2 litres up to 8,000 litres. 6 Product overview 203 We reserve the right to change designs and technical specifications of our products.

2 Expansion Vessels Product overview 203 We reserve the right to change designs and technical specifications of our products. 7

3 Expansion Vessels Overview Fixed Diaphragm Removable bladder Diaphragm Removable Flexcon Intermediate bladder Vessels Contra-Flex litres. Max. operating pressure; 3 bar: 8-35 litres, 6 bar: litres. Flexcon M 80-8,000 litres. Max. operating pressure: 6/0/6/25 bar. High-quality industrial tank. Larger dimensions available on request. Flexcon VSV For central heating systems in which the inlet temperature exceeds 90 C or the return temperature exceeds 70 C. Max. operating temperature: 60 C. Operating pressure: 6/0 bar. Flexcon C 2 -,000 litres. Max. operating pressure: 3 bar For small installations. Flexcon PRO 200 -,000 litres. Max. operating pressure: 6 bar. Flexcon V-B For central heating systems in which the inlet temperature exceeds 90 C or the return temperature exceeds 70 C. Max. operating temp.: 20/60 C. Max. operating pressure: 6/0 bar. Flexcon 0 -,000 litres. Max. operating pressure: 6 bar: 0 -,000 litres, 0 bar: 0 -,000 litres. For systems large and small. Flexcon TOP 8-80 litres. Max. operating pressure: 6 bar. High-pressure alternative for smaller systems. Cubex R 2-8 litres. Max. operating pressure: 3 bar. Space-saving alternative for smaller systems. Flexcon Solar 8 -,000 litres. Max. operating pressure: 8 bar: 8-80 litre, 0 bar: 0 -,000 litres. For solar systems. Flexcon P 8-50 litres. Max. operating pressure: 3 bar. Space-saving alternative for smaller systems. 8 Product overview 203 We reserve the right to change designs and technical specifications of our products.

4 Expansion Vessels Flexcon P: Space Saving Expansion Vessels of Superior Quality Butyl rubber diaphragm: Excellent pre-charge gas pressure maintenance. Pre-formed convex diaphragm with flexible 'rolling' action prevents the diaphragm from stretching. The proven Flamco clamp ring construction permits the use of a butyl rubber diaphragm that is approximately half the size of a full diaphragm in a comparable vessel. This ensures reduced permeability and a long service life for the expansion vessel. Quick, easy and space saving installation using the wall mounting bracket. 5 year warranty. FLEXCON P 8 FLEXCON P 25 FLEXCON P 35 FLEXCON P 50 Product overview 203 We reserve the right to change designs and technical specifications of our products. 9

5 Vessel Calculation for Central Heating Systems Calculation for a Flexcon expansion vessel for central heating systems with fixed or removable diaphragm Basic parameters for the calculation of a Flexcon expansion vessel. Initial pressure of the Flexcon expansion vessel This is the pressure measured at the nitrogen filler valve at ambient temperature and atmospheric pressure. The pressure is equivalent to the static height, rounded up to a factor of 0.5 bar. Vessel volume This is the total capacity of the Flexcon expansion vessel. Vessel efficiency This is the maximum amount of expansion water that can be contained in the vessel. Static height This is the height of the system from the Flexcon expansion vessel connection to the highest point of the system measured in water column metres, ( wcm 0. bar). Maximum working pressure This is the maximum permissible system pressure at the Flexcon expansion vessel. The maximum working pressure may not exceed the maximum value indicated on the expansion vessel. Output This is the ratio between the gross and net vessel capacity. Net contents Output = Gross capacity The output is determined by the ratio between initial and end pressure. In formulaic form, this is as shown below (derived from Boyle's Law): end pressure initial pressure Output = end pressure Pre-charge pressure Pre-charge pressure 0.5 bar Pre-charge pressure.0 bar 20 Product overview 203 We reserve the right to change designs and technical specifications of our products.

6 Expansion Vessels Note: pressure in bar absolute Max. output of Flexcon expansion vessels with fixed diaphragm Max. output of Flexcon 800 litre expansion vessel = 0.5, Flexcon,000 litre expansion vessel = 0.4. Max. output of Flexcon M = If the maximum output of an expansion vessel is exceeded, the diaphragm may be subjected to tensile stress. This could lead to damage to the diaphragm or even cause it to rupture. System water capacity This is the total volume of water in the entire system including heat source, radiators, pipe work etc. Expansion volume The expansion volume is calculated as follows: expansion volume = water capacity x increase in volume at average heating temperature. Example: heating temperature 90/70 C (average 80 C) = 2.89%. Safety factor We recommend including a margin of 25% when calculating the expansion volume. Gross capacity of Flexcon expansion vessels The gross capacity of Flexcon expansion vessels is calculated as follows: expansion volume x.25 Gross capacity of vessel = output Product overview 203 We reserve the right to change designs and technical specifications of our products. 2

7 Increase in volume of water in % The table below shows the percentage volume increase of water as temperature increases from 0 C to 0 C. Temperature in the Flexcon expansion vessel The maximum continuous temperature in the Flexcon expansion vessel is 70 C. The minimum permissible temperature in the Flexcon expansion vessel is -0 C. Temperature increase [ C] Volume increase [%] Volume increase [%] Temperature [ C] 22 Product overview 203 We reserve the right to change designs and technical specifications of our products.

8 Expansion Vessels Output In this table you can read off the output for various levels of initial and end pressure. We recommend a margin of at least.5 bar between the initial and end pressure. Static height [m] Initial pressure End pressure Approximation of the water capacity of the system In order to be able to determine the required capacity of the Flexcon vessel, the water capacity of the system as a whole must be calculated. If it is not possible to determine the capacity of the system, it can be approximated using the historic data shown here, based on a supply/return temperature of 90/70 C. The water capacity of the system can be approximated by multiplying the output of the system by the values specified in the table. The table refers to new systems. For older systems, we recommend using higher values. This method is an indication only and does not guarantee a precise calculation of the capacity required for your Flexcon expansion vessel. Central heating system with [l/kw] [860 kcal/h] convectors and/or air heaters 5.2 induction units 5.5 air treatment systems 6.9 panel radiators 8.8 central heating utilities mix 0.0 column radiators 2.0 cooled water utilities mix 20.0 heated ceiling and/or under-floor heating 8.5 extensive pipework (district heating) 25.8 Product overview 203 We reserve the right to change designs and technical specifications of our products. 23

9 Example calculations for Flexcon expansion vessels Example Data - water capacity = 340 liters - average heating temperature (90/70 ºC) = 80 ºC - system height = 8 m - end pressure = 3.0 bar - Flexcon expansion vessel and boiler placed above. Calculation Increase in volume in % = 2.89% 2.9% 340 x 2.9 Expansion volume = = 9.86 liters 00 Reserve 25% = 9.9 x.25 = 2.4 liters (3.0 + ) - (0.5 + ) Output = = 0.63 (3.0 + ) Required gross capacity of the 2.4 Flexcon expansion vessel = = 9.7 liters 0.63 The ideal model is a Flexcon 25/0.5. Example 2 Data - capacity unknown - boiler output = 280 kw - average heating temperature (80/60 ºC) = 70 ºC - system height = 2 m - end pressure = 3.0 bar - Flexcon expansion vessel and boiler placed below. - system components: 00% panel radiators Calculation Calculated system capacity = 280 x 8.8 = 2,464 liters Increase in volume in % = 2.25% 2,464 x 2.25 Expansion volume = = 55.4 liters 00 Reserve 25% = 55.4 x.25 = 69.3 liters (3.0 + ) - (.5 + ) Output = = (3.0 + ) Required gross capacity of the 69.3 Flexcon expansion vessel = = 84.8 liters The ideal model is a Flexcon 200/ Product overview 203 We reserve the right to change designs and technical specifications of our products.

10 Expansion Vessels Theory Minimum working pressure Specific circulation pumps demand a certain pressure (for instance bar) in their suction pipe in order to function properly. Many modern central heating boilers are protected to a minimum working pressure of 0.8 or bar. If such a pump or boiler is built in to a central heating system with a low static height, it may be more sensible to set the initial pressure of the expansion vessel to bar rather than 0.5 bar. Note that the increased initial pressure does not ensure that the minimum working pressure is replicated throughout the system! The chance of negative pressure being created high up in the system when it is cooling down, which would cause air circulation problems, is greater if the initial pressure is, say, bar than if the initial pressure were set at 0.5 bar. If the pressure in the system drops below bar, expansion vessels with initial pressure of bar cannot give back water to the system as the expansion vessel would run dry! Boost pressure In order to prevent negative pressure and air circulation problems, it is of the greatest importance that the expansion vessel does not run dry. This is why Flamco recommends that you fill the system when it is cold and at a pressure equal to the initial pressure plus 0.2 to 0.3 bar (if you are topping up a warmer system, the pressure must, accordingly, be higher). An incorrect, excessive boost pressure may lead to problems. If the system in which a expansion vessel is fitted and an initial pressure of 0.5 bar is filled to 2 bar rather than 0.8 bar, 30% more of the gross capacity will already have been used up before the central heating water expands due to the increase in temperature! (3 + ) - (0.8 + ) A = = 0.55 = 55% (3.0 + ) (3 + ) - (2 + ) B = = 0.25 = 25% (3 + ) Difference in output ( ): 30% Conclusion A higher initial pressure in a expansion vessel does not guarantee higher system pressure. An incorrect, excessive boost pressure has an undue impact. Flamco recommends filling the system to the right pressure, preferably 0.2 to 0.3 bar above the initial pressure of the Flexcon expansion vessel (when cold). Assistance To make the correct calculation in respect of which Flexcon expansion vessel to use, Flamco can offer all sorts of assistance; we can provide technical documentation, disc calculators and computer programs. N.B.: The right place for the expansion vessel is in the system s return line, on the suction side of the circulation pump. Product overview 203 We reserve the right to change designs and technical specifications of our products. 25

11 Vessel Calculation for Cooling Systems In a cooling system, Flexcon expansion vessels may have the following functions: As the system cools, the volume of the cooling water shrinks. The Flexcon expansion vessel thus gives water back to the system, maintaining system pressure. If the system is turned off, the water can return to the ambient temperature, allowing it to expand. The vessel absorbs this expansion volume. The Expansion Coefficient of Antifreeze All Flexcon expansion vessels can be used in systems in which glycol-based anti-freeze is added to the system water. The table below shows the increase in volume of various water/ethylene glycol mixing ratios. These are average values. Expansion coefficient of water with and without added anti-freeze Temperature [ C] Percentage of glycol 0% 0% 20% 30% 40% 50% Volume Increase [%] vol.% [-40 C] 44 vol.% [-30 C] 39 vol.% [-25 C] 34 vol.% [-20 C] 28 vol.% [-5 C] 20 vol.% [-0 C],3 0,78 0,64 0,44 0,3 0, Temperature [ C] 0 vol.% = water 26 Product overview 203 We reserve the right to change designs and technical specifications of our products.

12 Expansion Vessels Calculation for a Cooling System The following data is required to calculate the required volume of Flexcon expansion vessel: Volume of system water. Percentage of added anti freeze. Lowest system temperature. Maximum system temperature (= highest ambient temperature). Water - anti-freeze mix expansion (percentage). Static height of the system above the vessel. Maximum working pressure. The initial pressure of the expansion vessel is selected to match the static height of the system (above the expansion vessel). The following formula can be used to calculate the fill level of the expansion vessel at the lowest operating pressure. lowest operating pressure - initial pressure I = fill level lowest operating pressure This means that the residual factor of the expansion vessel can be determined. Residual factor = - fill level. The end pressure must be 0.5 bar lower than the set pressure of the safety valve. The output is calculated using the formula below: end pressure - lowest operating pressure II x residual factor = output end pressure Note: Pressure in bar absolute. Max. output of Flexcon expansion vessels with fixed diaphragm Max. output of Flexcon 800 liter expansion vessel = 0/5, Flexcon.000 liter expansion vessel = 0/4. Max. output of Flexcon M = The temperature in the Flexcon expansion vessel must remain above -0 ºC. A buffer vessel or Flexcon intermediate expansion vessel may have to be fitted between the system and the Flexcon expansion vessel. For calculations of Flexcon expansion vessels for Solar installations, refer to the spreadsheet on Product overview 203 We reserve the right to change designs and technical specifications of our products. 27

13 Flamco Flexcon The Top in Pressure Expansion Vessels Flamco s standard programme covers a wide range of expansion vessels from 2-8,000 liters with a wide choice of pre-charge pressures and maximum operating pressures. All models are characterised by their construction, superior quality diaphragms or bladders, high quality coating on the expansion vessel itself and efficient production methods. Why Flexcon is the best choice The rolling action of the diaphragm prevents stretching.this has a significant impact on its service life. The unique clamp construction damages neither the diaphragm nor the two halves of the expansion vessel. The thread of the water connection is uncoated to ensure easy and water tight installation. All vessels are factory tested. The two halves of the vessel are coated prior to assembly. Flexcon expansion vessels are delivered in a stackable cardboard packaging with hand grip and each box contains clear assembly instructions. Flexcon expansion vessels are always in stock at our wholesalers and our own warehouses. Qualified Flamco employees will be happy to give you advice and support. They are just a telephone call away. FLEXCON 2-4 FLEXCON 8-25 FLEXCON FLEXCON 0 -,000 Other reasons for choosing Flexcon Excellent service before, during and after installation. Handy accessories for mounting or disconnecting Flexcon expansion vessels. Our diaphragms are suitable for use with antifreeze. Exact details are available on request. The nitrogen valve of Flexcon 8-80 litre expansion vessels is countersunk and and is protected by a dust cap and plastic cover. The two halves of the vessel are coated prior to assembly. 28 Product overview 203 We reserve the right to change designs and technical specifications of our products.

14 Expansion Vessels Systems with Flexcon expansion vessels. Flexcon expansion vessel. 2. Prescor Safety valve. 3. Flamco tundish. 4. Flamcovent or Flexair air separator. 5. Flexfast quick-release coupling. 6. Flexcon pressure gauge. The diaphragm has a extremely low permeability The thread of the water connection is uncoated to ensure easy and water tight installation. The rolling action of the diaphragm prevents stretching. This has a significant impact on its service life. The nitrogen valve of Flexcon 8-80 litre expansion vessels is countersunk and and is protected by a dust cap and plastic cover. The unique clamp construction damages neither the diaphragm nor the two halves of the expansion vessel. When cold, the nitrogen cushion presses the diaphragm against the wall of the Flexcon expansion vessel. When heated, the expansion vessel partially fills with water and the nitrogen gas is compressed. When heated further, the expansion vessel portion fully fills with water and the nitrogen gas is fully compressed. If the pressure rises too high, the Prescor valve opens. The excess water/steam is discharged. Product overview 203 We reserve the right to change designs and technical specifications of our products. 29

15 CONTRA-FLEX For sealed heating and chilled water (cooling) installations. When the temperature in the installation rises, the system water will expand. The expansion water is stored temporarily in the expansion vessel to keep the pressure in the installation at the correct level. Each vessel is factory tested. Diaphragm: Flexible rubber with rolling action. Suitable for addition of glycol-based anti-freeze up to 50%. Max. temperature on diaphragm (EN 383/8): 70 C. Max. temperature at (heating) outlet: 20 C. In accordance with Pressure Equipment Directive 97/23/EC. Contra-Flex W 8-35 Maximum operating pressure: 3.0 bar. Deep drawn zinc plated steel clench ring. White (RAL 900) epoxy powder coating. Contra-Flex W / 4" Contra-Flex W / 4" Contra-Flex W / 4" Contra-Flex W / 4" Contra-Flex W / 4" Contra-Flex W Maximum operating pressure: 6.0 bar. Deep drawn zinc plated steel clench ring. White (RAL 900) epoxy powder coating. Contra-Flex W / 4" Contra-Flex W " Contra-Flex Maximum operating pressure: 6.0 bar. All welded construction. Red (RAL 3002) epoxy powder coating. Contra-Flex " Contra-Flex " Product overview 203 We reserve the right to change designs and technical specifications of our products.

16 Expansion Vessels FLEXCON C For sealed heating and chilled water (cooling) installations. When the temperature in the installation rises, the system water will expand. The expansion water is stored temporarily in the expansion vessel to keep the pressure in the installation at the correct level. Each vessel is factory tested. The diaphragm is clamped between two vessel halves, preventing mechanical damage to the diaphragm or vessel halves during use. Compared to other bladder type vessels, the clamp ring construction cuts the air to water diaphragm surface ratio in half, resulting in a much lower permeability of the gas charge, a greater reliability and overall life expectancy of the vessel. The thread of the system connection is uncoated, ensuring problem free connection. Diaphragm: Flexible rubber with rolling action. Suitable for addition of glycol-based anti-freeze up to 50%. Red (RAL 3002) epoxy powder coating. Max. temperature on diaphragm (EN 383/8): 70 C. Max. temperature at (heating) outlet: 20 C. In accordance with Pressure Equipment Directive 97/23/EC. Flexcon C 2-25 Maximum operating pressure: 3.0 bar. Deep drawn zinc plated steel clench ring. Flexcon C 2 2 0, / 4", Flexcon C / 4" Flexcon C 4 4 0, / 4", Flexcon C / 4" Flexcon C / 4" Flexcon C / 4" Flexcon C 8 8 0, / 4" Flexcon C / 4" Flexcon C , / 4" Flexcon C / 4" Flexcon C Maximum operating pressure: 3.0 bar. Deep drawn zinc plated steel clench ring. Flexcon C / 4" Flexcon C , / 4" Flexcon C 50 50, / 4" Flexcon C / 4" Flexcon C / 4" Flexcon C , " Flexcon C 80 80, " Flexcon C " Flexcon C " Product overview 203 We reserve the right to change designs and technical specifications of our products. 3

17 Flexcon C Maximum operating pressure: 6.0 bar. All welded construction. Red (RAL 3002) epoxy powder coating. [litres] (bar) Height (mm) 8 Flexcon C " 23,8 70 Flexcon C " 23,8 8 7 Flexcon C " 23, Flexcon C 0 0 specify " 23, Flexcon C " 25, Flexcon C " 25, Flexcon C " 25, Flexcon C specify " Flexcon C " 38, Flexcon C " 38, 8 72 Flexcon C " 38, Flexcon C specify " Flexcon C " 56, Flexcon C " 56, Flexcon C " 56, Flexcon C specify " Flexcon C " 76,4 740 Flexcon C " 76,4 74 Flexcon C " 76,4 742 Flexcon C specify " Flexcon C " 92,9 760 Flexcon C " 92,9 76 Flexcon C " 92,9 762 Flexcon C specify " Flexcon C " 26,9 780 Flexcon C " 26,9 78 Flexcon C specify " Flexcon C " 45,9 790 Flexcon C specify " Product overview 203 We reserve the right to change designs and technical specifications of our products.

18 Expansion Vessels FLEXCON For sealed heating and chilled water (cooling) installations. When the temperature in the installation rises, the system water will expand. The expansion water is stored temporarily in the expansion vessel to keep the pressure in the installation at the correct level. Each vessel is factory tested. All welded construction. Diaphragm: Flexible rubber with rolling action. Suitable for addition of glycol-based anti-freeze up to 50%. Red (RAL 3002) epoxy powder coating. Max. temperature on diaphragm (EN 383/8): 70 C. Max. temperature at (heating) outlet: 20 C. In accordance with Pressure Equipment Directive 97/23/EC. Flexcon bar Maximum operating pressure: 6.0 bar. Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon 0 0 specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Product overview 203 We reserve the right to change designs and technical specifications of our products. 33

19 Flexcon bar Maximum operating pressure: 0.0 bar. Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon 0 0 specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon " Flexcon specify " Product overview 203 We reserve the right to change designs and technical specifications of our products.

20 Expansion Vessels FLEXCON TOP For sealed heating and chilled water (cooling) installations. When the temperature in the installation rises, the system water will expand. The expansion water is stored temporarily in the expansion vessel to keep the pressure in the installation at the correct level. Each vessel is factory tested. Diaphragm: Flexible rubber with rolling action. Suitable for addition of glycol-based anti-freeze up to 50%. Red (RAL 3002) epoxy powder coating. Max. operating pressure: 6.0 bar. Max. temperature on diaphragm (EN 383/8): 70 C. Max. temperature at (heating) outlet: 20 C. In accordance with Pressure Equipment Directive 97/23/EC. Flexcon Top 2-25 Deep drawn zinc plated steel clench ring. Flexcon Top / 4" Flexcon Top / 4" Flexcon Top / 4" Flexcon Top 8 8 specify / 4" Flexcon Top / 4" Flexcon Top / 4" Flexcon Top / 4" Flexcon Top 2 2 specify / 4" Flexcon Top / 4" Flexcon Top / 4" Flexcon Top / 4" Flexcon Top 8 8 specify / 4" Flexcon Top / 4" Flexcon Top / 4" Flexcon Top / 4" Flexcon Top specify / 4" Flexcon Top Deep drawn zinc plated steel clench ring. Flexcon Top / 4" Flexcon Top / 4" Flexcon Top / 4" Flexcon Top / 4" Flexcon Top specify / 4" Flexcon Top / 4" Flexcon Top / 4" Flexcon Top / 4" Flexcon Top / 4" Flexcon Top specify / 4" Flexcon Top " Flexcon Top " Flexcon Top " Flexcon Top specify " Product overview 203 We reserve the right to change designs and technical specifications of our products. 35

21 FLEXCON SOLAR Expansion vessels for solar powered installations. Suitable for addition of glycol-based anti-freeze up to 50%. In accordance with Pressure Equipment Directive 97/23/EC. Flexcon Solar 8-25 Deep drawn zinc plated steel clench ring. White (RAL 900) epoxy powder coating. Maximum operating pressure: 8.0 bar. Maximum temperature load on the diaphragm: 0 C. Flexcon Solar / 4" Flexcon Solar / 4" Flexcon Solar / 4" Flexcon Solar / 4" Flexcon Solar Deep drawn zinc plated steel clench ring. White (RAL 900) epoxy powder coating. Maximum operating pressure: 8.0 bar. Maximum temperature load on the diaphragm: 0 C. Flexcon Solar / 4" Flexcon Solar / 4" Flexcon Solar " Flexcon Solar All welded construction. Red (RAL 3002) epoxy powder coating. Maximum operating pressure: 0.0 bar. Maximum temperature load on the diaphragm (EN 383/8): 70 C. Flexcon Solar " Flexcon Solar " Flexcon Solar " Flexcon Solar " Flexcon Solar " Flexcon Solar " Flexcon Solar " Flexcon Solar " Product overview 203 We reserve the right to change designs and technical specifications of our products.

22 Expansion Vessels CUBEX R For sealed heating and chilled water (cooling) installations. When the temperature in the installation rises, the system water will expand. The expansion water is stored temporarily in the expansion vessel to keep the pressure in the installation at the correct level. Each vessel is factory tested. Deep drawn zinc plated steel clench ring. Diaphragm: Flexible rubber with rolling action. Suitable for addition of glycol-based anti-freeze up to 50%. Max. operating pressure: 3.0 bar. Max. temperature on diaphragm (EN 383/8): 70 C. Max. temperature at (heating) outlet: 20 C. In accordance with Pressure Equipment Directive 97/23/EC. Cubex R Cubex R / 4" Cubex R / 4" Cubex R / 4" FLEXCON P Expansion vessel with reduced height and suspension eye for use in sealed heating and cooling installations. When the temperature in the installation rises, the system water will expand. The expansion water is stored temporarily in the expansion vessel to keep the pressure in the installation at the correct level. Each vessel is factory tested. The oval shape combined with the practical suspension eye enables quick and easy mounting, optimising the use of space. Thanks to the design no rest water remains in the vessel. Deep drawn zinc plated steel clench ring. Suitable for addition of glycol based anti freeze up to 50%. Red (RAL 3002) epoxy powder coating. Max. working pressure: 3.0 bar. Max. temperature on diaphragm (EN 383): 90 C. Max. temperature at (heating) outlet: 20 C. Vessel of high tensile steel. Diaphragm material: butyl rubber. In accordance with Pressure Equipment Directive 97/23/EC. Flexcon P Flexcon P / 4" Flexcon P / 4" Flexcon P / 4" Flexcon P / 4" Product overview 203 We reserve the right to change designs and technical specifications of our products. 37

23 Flexcon M A Flexcon M expansion vessel offers you advantages in installations with big differences in the static pressure and set pressure of the safety valve. All Flexcon M expansion vessels are fitted with an exchangeable bladder. This bladder forms the separation between the expansion water inside the bladder and the nitrogen cushion. The Flexcon M s flange construction allows you to replace the butyl-rubber bladder. High efficiency means that the capacity of the vessel is used to best effect. As an option, the Flexcon M expansion vessel can be fitted with a Flexvent Super Automatic Air Vent. Each Flexcon M expansion vessel is fitted with a pressure gauge as standard. From 2,800 litres all Flexcon M expansion vessels are fitted with an adjustable foot. FLEXCON M Systems with more than one boiler:. Flexcon expansion vessel (depending on boiler capacity). 2. Prescor safety valve or Prescomano. 3. Flamco tundish. 4. Flexcon Connection Assembly ½". 5. Flexcon pressure gauge or combined pressure gauge/thermometer. 6. Flamco venting equipment. 7. One or more Flexcon M vessels. 8. Flamco pressurisation unit. 38 Product overview 203 We reserve the right to change designs and technical specifications of our products.

24 Expansion Vessels FLEXCON M For heating and chilled water (cooling) installations. The vessel is equipped with a replaceable bladder made from high-quality butyl rubber in compliance with EN 383/8. Particular benefits of use are achieved in installations with large variations between static pressure and pre-set pressure of the safety valve. Accessories to be ordered separately. Replaceable bladder. With inspection cover and pressure gauge. With height-adjustable feet (From 2,800 litres). Delivered ready for connecting to system. Suitable for addition of glycol-based anti-freeze up to 50%. Red (RAL 3002) epoxy powder coating. Max. temperature on diaphragm (EN 383/8): 70 C. Max. temperature at (heating) outlet: 20 C. In accordance with Pressure Equipment Directive 97/23/EC. Material quality: - ASTM/ISO: A8 class 60 / S235JRG2. Flexcon M bar Maximum operating pressure: 6.0 bar. Flexcon M " Flexcon M / 4" Flexcon M / 4" Flexcon M / 4" Flexcon M / 2" Flexcon M / 2" Flexcon M / 2" Flexcon M " Flexcon M / 2" Flexcon M / 2" Flexcon M / 2" Flexcon M DN 00 * Flexcon M DN 00 * * Flanges as per EN 092- PN 6. Flexcon M bar Maximum operating pressure: 0.0 bar. Flexcon M " Flexcon M / 4" Flexcon M / 4" Flexcon M / 4" Flexcon M / 2" Flexcon M / 2" Flexcon M / 2" Flexcon M / 2" Flexcon M " Flexcon M / 2" Flexcon M / 2" Flexcon M / 2" Flexcon M DN 00 * Flexcon M DN 00 * * Flanges as per EN 092- PN 6. Product overview 203 We reserve the right to change designs and technical specifications of our products. 39

25 Flexcon Pro A Flexcon Pro expansion vessel offers you extra-special advantages in installations with big differences in the static pressure and set pressure of the safety valve. Diaphragm pressure expansion vessel with an exchangeable bladder according to DIN 4807/3. For the use in heating installations with a working temperature of 20 C (maximum temperature (bladder) of 70 C) and for chilled water (cooling and airconditioning) installations. From 770 liters or more the Flexcon Pro expansion vessels are fitted with a pressure gauge. High efficiency means that the capacity of the expansion vessel is used to best effect. Thanks to its threaded connection, a Flexcon Pro expansion vessel can be installed easily and costeffectively onto the system. FLEXCON PRO Systems with more than one boiler:. Flexcon expansion vessel (depending on boiler capacity). 2. Prescor safety valve or Prescomano. 3. Flamco tundish. 4. Flexcon Connection Assembly ½". 5. Flexcon pressure gauge or combined pressure gauge/thermometer. 6. Flamco venting equipment. 7. One or more Flexcon M vessels. 8. Flamco automatic top-up unit. 40 Product overview 203 We reserve the right to change designs and technical specifications of our products.

26 Expansion Vessels FLEXCON PRO For heating and chilled water (cooling) installations. Replaceable bladder. Red (RAL 3002) epoxy powder coating. Suitable for addition of glycol-based anti-freeze up to 50%. Max. operating pressure: 6.0 bar. Max. temperature on diaphragm (EN 383/8): 70 C. Max. temperature at (heating) outlet: 20 C. In accordance with Pressure Equipment Directive 97/23/EC. Material quality: ASTM/ISO: A8 class 60 / S235JRG2. Flexcon PRO Flexcon PRO " Flexcon PRO " Flexcon PRO " Flexcon PRO " Flexcon PRO " Flexcon PRO " Flexcon PRO " Flexcon PRO " Flexcon PRO " Flexcon PRO " Product overview 203 We reserve the right to change designs and technical specifications of our products. 4

27 Flexcon VSV/VB Intermediate Vessels In sealed heating systems, the supply temperature can reach 20 C. The maximum permissible continuous temperature load on the diaphragm in the Flexcon vessels is 70 C in compliance with the appropriate standard. That is why Flexcon expansion vessels must be fitted in the return line. If the temperature in the return line is not capped at 70 C, an intermediate vessel must be fitted. In this intermediate vessel the expansion water is allowed to cool. The maximum supply temperature of the water for Flexcon VSV/VB vessels is 60 C. The extent to which the expansion water is cooled depends on the volume of the intermediate vessel. An intermediate vessel must not be insulated. Around the vessel and between the vessel and the ceiling there must be clearance of at least 400 mm. System water flows from the installation into the top of the intermediate vessel. The hot water mixes in the vessel with the cold water already in the vessel. From the bottom of the vessel, significantly cooler water is fed into the expansion vessel. The temperature of the expansion water that is supplied to the Flexcon expansion tank remains under the maximum temperature permissible for the membrane. Calculation for a Flexcon VSV/VB intermediate vessel The required volume of a Flexcon VSV/VB intermediate vessel depends on the supply temperature and a percentage of the net expansion volume as per the table below. Supply temperature Flexcon intermediate vessel volume % of the net expansion volume 90-0 C 5-25 C C C 60 Example calculation for a Flexcon intermediate vessel Data: - expansion volume =.740 litres - supply temperature (05/95 C) = 05 C Calculation: Required vessel volume = 5% of the expansion volume 5 x.740 = = 26 litres 00 The ideal intermediate vessel is thus the Flexcon VSV 350. Flexcon intermediate vessel connection diagram The intermediate vessel functions according to the principle that hot water is lighter than cold water. As the intermediate vessel is filled with water from the top, the heat will be concentrated there. System water that has been allowed to cool will, due to its greater density, fall and this cooler water will naturally be forced towards the connection on the underside of the expansion vessel. (Automatic) Vent FLEXCON VSV Drain Expansion line 42 Product overview 203 We reserve the right to change designs and technical specifications of our products.

28 Expansion Vessels FLEXCON INTERMEDIATE VESSELS Vessels to protect Flexcon expansion vessels on elevated temperature systems. The vessels are fitted in between the expansion vessel and the system return. Red (RAL 3002) epoxy powder coating. Suitable for addition of glycol-based anti-freeze up to 50%. In accordance with Pressure Equipment Directive 97/23/EC. Material quality: ASTM/ISO: A8 class 60 / S235JRG2. Flexcon VSV bar Maximum working temperature (design): 60 C. Connection to Vessel System (F) (F) Flexcon VSV / 2" / 2" Flexcon VSV / 2" / 2" Flexcon VSV " 2" Flexcon VSV " 2" Flexcon VSV " 2" Flexcon VSV bar Maximum working temperature (design): 60 C. Connection to Vessel System (F) (F) Flexcon VSV / 2" / 2" Flexcon VSV / 2" / 2" Flexcon VSV " 2" Flexcon VSV " 2" Flexcon VSV " 2" Flexcon V-B bar Maximum working temperature (design): 20 C. Connection Vessel System (F) V-B / 2" / 2" V-B " 2" Flexcon V-B bar Maximum working temperature (design): 60 C. Connection Vessel System (F) V-B / 2" / 2" V-B " 2" Product overview 203 We reserve the right to change designs and technical specifications of our products. 43

FLEXCON EXPANSION VESSELS. Flamco FLEXCON 2-80. Flexcon. Expansion vessels FLEXCON 110 1000 FLEXCON M. Flamco FLEXCON V-B.

FLEXCON EXPANSION VESSELS. Flamco FLEXCON 2-80. Flexcon. Expansion vessels FLEXCON 110 1000 FLEXCON M. Flamco FLEXCON V-B. FLEXCON EXPANSION VESSELS Flamco 1 Flexcon Expansion vessels FLEXCON 2-80 FLEXCON 110 1000 FLEXCON M Flamco FLEXCON V- 2007 edition / UK Flamco Flexcon the first name in expansion vessels Flamco has over

More information

Flamco Diaphragm pressure expansion vessels

Flamco Diaphragm pressure expansion vessels FLEXCON expansion vessels Your reliable partner 1 Flamco Diaphragm pressure expansion vessels FLEXCON C 2-80 FLEXCON P FLEXCON 110-1000 FLEXCON M FLEXCON V-B EDition exp 2008 Diaphragm pressure expansion

More information

Flamco. Flexcon M. Installation and operating instructions. 2002 Flamco 18501067

Flamco. Flexcon M. Installation and operating instructions. 2002 Flamco 18501067 Flexcon M E Installation and operating instructions 2002 Flamco 1801067 Flamco b.v. P.O. Box 11 2800 AC Gouda - Holland Industriestraat 6 2802 AC Gouda - Holland Tel.: +31(0)182 91800 Fax: +31(0)182 227

More information

solarplus solar systems general features

solarplus solar systems general features SOLARPLUS solar systems solarplus Applications: expansion vessels for solar systems Zilmet, an internationally operating company with over 50 years of experience has grown to be the biggest European producer

More information

AIR AND DIRT SEPARATORS. Flamco FLEXVENT. Air and dirt separators FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S.

AIR AND DIRT SEPARATORS. Flamco FLEXVENT. Air and dirt separators FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S. AIR AND DIRT SEPARATORS 7 Flamco FLEXVENT FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN 2007 edition / UK FLAMCO A-S Flexvent : reliable and easy to mount The Flexvent 3 /8 and 1 /2 are supplied together

More information

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol

More information

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy VIESMANN VITOSOL 200-F Flat-plate collector for the utilisation of solar energy Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 13 VITOSOL 200-F Type SV2 and SH2 Flat-plate

More information

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet

More information

Draining and filling cooling system

Draining and filling cooling system Page 1 of 9 Draining and filling cooling system Special tools and workshop equipment required Adapter -V.A.G 1274/8- Pipe -V.A.G 1274/10- Drip tray -V.A.G 1306- or drip tray for workshop hoist -VAS 6208-

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013 ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 0 QUALITY 0 YEAR GUARANTEE Exclusively distributed by: Table of contents Panel radiators General / Guarantee Technical data and radiator dimensions

More information

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant

More information

1 DESCRIPTION OF THE APPLIANCE

1 DESCRIPTION OF THE APPLIANCE 1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19) 19 Engine - Cooling System (Page GR-19) Cooling system draining and filling general information Body components, layout Engine components, layout Radiator fan run-on checking Recommended mixture ratios

More information

Blowdown vessels Meeting the requirements of HSE PM60

Blowdown vessels Meeting the requirements of HSE PM60 Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove

More information

Flamco. Products for Solar powered installations. Your reliable partner FLEXCON SOLAR FLEXCON V-B PRESCOR SOLAR FLEXVENT TOP SOLAR FLAMCOVENT SOLAR V

Flamco. Products for Solar powered installations. Your reliable partner FLEXCON SOLAR FLEXCON V-B PRESCOR SOLAR FLEXVENT TOP SOLAR FLAMCOVENT SOLAR V PRODUCTS FOR SOLR POWERED INSTLLTIONS Your reliable partner Flamco Products for Solar powered installations FLEXCON SOLR FLEXCON V- PRESCOR SOLR FLEXVENT TOP SOLR FLMCOVENT SOLR V DUO SOLR EDITION EXP

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

EXPANSION AUTOMATS. Flamco. Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA.

EXPANSION AUTOMATS. Flamco. Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA. EXPANSION AUTOMATS 2 Flamco Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA 2007 edition / UK Flexcon M-K, the powerful compressor expan Flexcon M-K automats consist

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Venting Range and Air/Dirt Separators

Venting Range and Air/Dirt Separators . Venting Range and Air/Dirt Separators Systems in which the water is properly de-aerated and free of contamination are more efficient, produce less noise and have a longer service life. Our products use

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

Session 2: Hot Water Supply

Session 2: Hot Water Supply MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:

More information

HDA -----------------------------------------------------------

HDA ----------------------------------------------------------- ----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes

More information

PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS

PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS I N S P I R E D E F F I C IEN C Y PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS INSPIRED EFFICIENCY Mikrofill Systems Ltd is a Midlands based British

More information

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =

More information

Zenith Solar thermal 4.5m pump station Installation manual

Zenith Solar thermal 4.5m pump station Installation manual Zenith Solar thermal 4.5m pump station Installation manual Product code: 20026145 INSTALLATION MANUAL WATER RETURN GROUP This instruction manual is an integral part of the installation and maintenance

More information

Select Radiators Installation Guide

Select Radiators Installation Guide Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall

More information

Accessories for Heating and Cooling Installations

Accessories for Heating and Cooling Installations . ccessories for Heating and ooling Installations Flamco has a complete range of products for safeguarding chilled and heating systems. The various models of Flamco Prescor safety relief valves are used

More information

Flamco. Flamco. Flamco. Venting range and dirt separators FLEXVENT FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S

Flamco. Flamco. Flamco. Venting range and dirt separators FLEXVENT FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S VENTING RNGE ND DIRT SEPRTORS Flamco Flamco Venting range and dirt separators FLEXVENT FLMCOVENT FLMCOVENT CLEN FLEXIR FLMCO CLEN Flamco Edition 2005 / EXP FLMCO -S Flamco Flexvent floatvents: reliable

More information

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston. SK Series Piston Types TYPE 2 pplication: Low-friction design for higher piston speeds, slow movements without stick-slip effect and high number of actuations (millions). ctual cycles achieved will vary

More information

ENERGY RETROFIT PROGRAM

ENERGY RETROFIT PROGRAM ENERGY RETROFIT PROGRAM An innovative but simple retrofit for existing hot water and chilled water piping systems that will help you save money. REDUCE FLOW BY 50% REDUCE PUMP HEAD BY 75% REDUCE PUMP POWER

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS

More information

Solar Hot Water Heaters

Solar Hot Water Heaters Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless

More information

Description of functions

Description of functions Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the

More information

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED. CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

building engineering services association specification for: Domestic Heating www.thebesa.com

building engineering services association specification for: Domestic Heating www.thebesa.com building engineering services association specification for: Domestic central Heating installation www.thebesa.com building engineering services association acknowledgments Guide to good practice: Domestic

More information

SunMor SM-V30 Solar Water Heater Installation Manual

SunMor SM-V30 Solar Water Heater Installation Manual SunMor SM-V30 Solar Water Heater Installation Manual Rev. 1.02 Congratulations on the purchase of your new SunMor SM-V30 from Nature s Comfort LLC! You must read this entire instruction manual before beginning

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

In-Line Air Separators

In-Line Air Separators Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI

More information

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009 Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVI is self-acting thermostatic actuator primarily for use for temperature control

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

BLADDER SURGE CONTROL SYSTEM

BLADDER SURGE CONTROL SYSTEM PART I GENERAL 1.01 Description BLADDER SURGE CONTROL SYSTEM This specification describes the requirements for a Bladder Surge Control System. The purpose of the system is to minimize transient pressures

More information

Stove-boiler for solid fuels 12-30 KW Directions for use and assembling

Stove-boiler for solid fuels 12-30 KW Directions for use and assembling Stove-boiler for solid fuels 12-30 KW Directions for use and assembling February 7, 2012 Contents 1 Technical data 2 1.1 Boiler properties TEMY PLUS 12-30 KW......................... 3 1.2 On Product............................................

More information

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert. Price List Rev.2 2010 AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.com SOMMARIO INDEX SOLAR SYSTEMS... page 10 COMPONENTS

More information

EXPANSION AUTOMATS. Flamco. Flamco. Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA. Flamco. 2005 Edition / EXP

EXPANSION AUTOMATS. Flamco. Flamco. Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA. Flamco. 2005 Edition / EXP EXPANSION AUTOMATS Flamco Flamco Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA Flamco 2005 Edition / EXP Flexcon M-K, the powerful compressor expan Flexcon M-K

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves

More information

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation) PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold

More information

Laddomat 21 Charging Unit

Laddomat 21 Charging Unit Laddomat 21 Charging Unit Part.No. 11 23 78 User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according

More information

UNDERSTANDING REFRIGERANT TABLES

UNDERSTANDING REFRIGERANT TABLES Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 UNDERSTANDING REFRIGERANT TABLES INTRODUCTION A Mollier diagram is a graphical representation of the properties of a refrigerant,

More information

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name. ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the

More information

SISTO-16TWA/HWA/DLU. Type Series Booklet

SISTO-16TWA/HWA/DLU. Type Series Booklet Diaphragm Valve SISTO-16TWA/HWA/DLU PN16 DN 15-200 Maintenance-free Flanged Ends Type Series Booklet Legal information/copyright Type Series Booklet SISTO-16TWA/HWA/DLU All rights reserved. The contents

More information

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Volkswagen Touareg 3.2 - Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! Hot steam may escape when opening expansion tank.

More information

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2 Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2 Please read and understand these instructions before starting work. Please leave this leaflet with

More information

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5

More information

Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized

Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized Gravity Solar System Installation Manual: This manual explains how to install a system of evacuated

More information

SOLAR WATER HEATER USER AND INSTALLATION MANUAL

SOLAR WATER HEATER USER AND INSTALLATION MANUAL SOLAR WATER HEATER USER AND INSTALLATION MANUAL SOLAR WATER HEATER USER AND INSTALLATION MANUAL Non-pressure series solar water heater SZ58/1800-10 SZ58/1800-15 SZ58/1800-18 SZ58/1800-20 Index System

More information

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100 MODEL - FCA & FCA-S HD FIRE PROTECT TECHNICAL DATA MODELS FCA-65, FCA-80 & FCA-100 Carbon Steel Construction FCA-S 65, FCA-S 80 & FCA-S 100 Stainless Steel Construction INLET SIZE 65, 80, 100 NB WORKING

More information

VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy

VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy Datasheet Part no. and prices: see pricelist VITOSOL 200-F Type SV2A/B and SH2A/B Flat-plate collector for vertical or horizontal

More information

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers COMMERCIAL HVAC CHILLER EQUIPMENT Air-Cooled Chillers Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They

More information

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME UNDERSTANDING HOT WATER SYSTEMS IN THE HOME This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential

More information

CHEMICAL CLEANING UNIT Product number: 737189

CHEMICAL CLEANING UNIT Product number: 737189 CHEMICAL CLEANING UNIT Product number: 737189-1 - v.05/16 Content Page Intro 3 Specifications 4 Installation 5 Safety precautions 7 Maintenance 8 Spares and Accessories 8 Unitor Chemicals 9 Notes 10-2

More information

SF15K SF05KSS, SF10KSS

SF15K SF05KSS, SF10KSS Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water

More information

Volkswagen Golf 5 2004-> VW Rabbit GTI 2006->

Volkswagen Golf 5 2004-> VW Rabbit GTI 2006-> Стр. 1 из 24 Volkswagen Golf 5 2004-> VW Rabbit GTI 2006-> 19-1 Cooling system components Warning! Hot steam may escape when opening expansion tank. Wear protective goggles and protective clothing to prevent

More information

Solar Collector Series. Product List

Solar Collector Series. Product List Solar Collector Series List FULL COLLECTORS (MANIFOLD, TUBES & ROOF FRAME) : CSR00051 Apricus Collector : AP10 10-Way Manifold, 10 Tubes and Standard Roof Frame CSR00052 Apricus Collector : AP20 20-Way

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

Cooling system components, servicing

Cooling system components, servicing 19-1 Cooling system components, servicing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate protection, cover the cap

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,

More information

Technical catalogue convectors POLAND 2012

Technical catalogue convectors POLAND 2012 Technical catalogue convectors POLAND 2012 index convectors review...3 Narbonne...4 Narbonne VT... 10 Narbonne V... 16 Narbonne V VT... 20 mounting distances for Narbonne...26 mounting distances for Narbonne

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

Condensing unit type EPSILON-ECHOS LE Technical information manual

Condensing unit type EPSILON-ECHOS LE Technical information manual Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps

More information

Thermo Siphon Solar Systems

Thermo Siphon Solar Systems Thermo Siphon Solar Systems Thermo Siphon Solar Systems are a very cost effective way of producing hot water due to their simplicity in design and installation requirements. Usually more common in hotter

More information

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district PLANT TORINO NORD Iren Energia is the company in the Iren Group whose core businesses are the production and distribution of electricity, the production and distribution of thermal energy for district

More information

BRAZED PLATE INSTALLATION MANUAL

BRAZED PLATE INSTALLATION MANUAL www.brazedplate.com BRAZED PLATE INSTALLATION MANUAL S.E.C. Heat Exchangers P.E.I. CANADA C0A 1A0 tel; 902-659-2424 fax; 902-659-2800 Table of Contents Description...2 Mounting position...3 Piping connections......3

More information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system

More information

Data sheet ECC 12 and 22

Data sheet ECC 12 and 22 Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe

More information

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com. Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

Series 510 Submersible Level Transmitters

Series 510 Submersible Level Transmitters Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable

More information

Bypass level indicator With magnetic display Model BNA

Bypass level indicator With magnetic display Model BNA Level measurement Bypass level indicator With magnetic display Model BNA WIKA data sheet LM 10.01 Applications Continuous level indication without power supply Indication of the level proportional to height

More information

8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en

8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en 8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................

More information

Instructions for designing heating systems.

Instructions for designing heating systems. Instructions for designing heating systems. In order to obtain the required effect, a lower consumption, a smaller quantity of impurities and improved comfort, heat and domestic hot water installations

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information