Product Data. A/RH Series Relative Humidity Transmitters

Size: px
Start display at page:

Download "Product Data. A/RH Series Relative Humidity Transmitters"

Transcription

1 Relative Humidity DISPLAYS A CI Product Data A/RH Series Relative Humidity Transmitters First in Sensor Quality The A/RH Series Relative Humidity transmitters, convert a resistance change to a linear to 0 ma, 0 to VDC, or 0 to 0 VDC output. The current signal may be transmitted over long distances on twisted-pair wire and will not be affected by the lead wire resistance or electrical noise. Accuracy is maintained over the entire operating range, using a thermistor for temperature compensation. All A/RH Series transmitters have a limited year warranty. %, %, %, and % Accuracies Low Drift Highly Repeatable Calibration Certificates Available Applications: Building Automation Systems PRESSURE Each A/RH Series humidity transmitter is calibrated using a NIST Traceable Temperature /Humidity Chamber. Both three and five point calibration certificates are avalable for % and % RH accuracies but they must be ordered separately. Field selectable output signals RELATIVE HUMIDITY The Advanced Ceramic Technology design overcomes the limitations of other resistance-based humidity sensors that utilize water-soluble polymer coatings. The Advanced Ceramic Technology enables these sensors to recover fully from condensation. This also allows the sensor to maintain its accuracy over a longer period of time. Despite its high accuracy, the Advanced Ceramic Technology sensor and related circuitry is economical. Attributes: Single point Field Calibration TEMPERATURE Product Description Light Industrial Pharmaceutical Supply Voltage 77oF Wiring Diagrams available at Data acquisition OEM Automation Components, Inc. 0 Pleasant View Rd. Middleton, WI PH: (08) 8-8 FAX: (08) C00000 rev.pdf RH- ACCESSORIES Long Term Stability Hysteresis Repeatablity Sensitivity Response Time Operating Temperature Range Operating Humidity Range Saturation Response Time Humidity Chambers AIR QUALITY Power Consumption RH Measurement Range RH Output 0 Ohm Load: + to VDC /.-. VAC 0-VDC: +- VDC /.-. VAC 00 Ohm Load: +8 to VDC /.-. VAC 0-0VDC: +8- VDC /.-. VAC VA max. 0 to 00% -wire, to 0mA (Factory Standard) -wire, 0-, 0-0 VDC or to 0mA +/- % over 0% span (between 0 to 90%) +/- %, %, or % from 0 to 9% Less than % drift / years Less than 0.% RH 0.% RH 0. % RH 0 seconds for % Step -0 to of (-. to 0oC) 0 to 9 % RH non-condensing 0 minutes for % Step CURRENT Product Specifications

2 DISPLAYS Dimensions Room.7" (70 mm)." (9 mm) Outside () PG /" (7 mm) NPT Knockouts.0" (9 mm) RELATIVE HUMIDITY TEMPERATURE." ( mm) Duct." (7 mm).8" (98 mm) 0." dia. (7 mm) 0.8" ( mm) O.D. Ref. Stainless Plate Mounting Hole Separation:.9" (8 mm) PRESSURE 7." (8 mm) 0.7" dia. (9 mm).0" ( mm) Plastic Washer.00" ( mm) CURRENT 0.7" (9 mm)." (7 mm) 0 Micron S.S. Sintered Filter.7" (70 mm) 0.7" dia. (9 mm) AIR QUALITY ACCESSORIES Ordering Information Accuracy Range if % Configuration A/ [ ] -[ ] -[ ] RH (+/- %) Please Specify (R) Room RH (+/- %) a 0% (D) Duct RH (+/- %) (i.e. 0-0%) (O) Outdoor Air RH (+/- %) (SP) Stainless Plate PT NIST Certificate ( point Calibration 0, 0 and 80% RH) PT NIST Certificate ( point Calibration Certificate w/standard points choosen by ACI) Example: A/RH-R or A/RH-D or A/RH-O or A/RH-(0 to 0%)-SP 0 Pleasant View Rd. Middleton Industrial Park Middleton, WI PH: (08) 8-8 FAX: (08) RH-

3 ACI Automation Components, Inc. Installation and Operation Instructions ACI/RH Room Series Please Read Instruction Carefully Before Installation! The ACI/RH Room Series transmitters are a universal Relative Humidity transmitter that can be powered with either a + to VDC or VAC supply voltage. The ACI/RH uses a half-wave bridge rectifier to convert the AC power to a useable DC voltage. Caution: When using a VAC transformer, ACI recommends that you use an isolated transformer. If sharing the transformer with your controller, valve, actuator, or any other device, be sure to connect all of the devices with the proper polarity, since most controllers are earth grounded. Failure to do so may result in damage to the ACI/RH, your controller, or any other devices that are attached due to a ground loop problem. The ACI/RH Room transmitters are designed with a field selectable -0 ma, 0- VDC, or 0-0 VDC output signal that is equivalent to 0 to 00% RH. Unless specified upon ordering, all units are shipped from the factory to accept DC power with a -wire, -0 ma loop-powered output. Caution: When changing the Output Selection Switch (SW) make sure that the power supply is turned off before making any changes. Failure to do this may cause damage to the unit. RH Wiring Diagram ACI recommends that all ACI/RH -0 ma Room relative humidity transmitters be wired with a to AWG -wire twisted pair or shielded cable for best results. All ACI/RH Room voltage output transmitters should use a -wire to AWG shielded cable. Note: When using a shielded cable, be sure to connect only () end of the shield to ground at the controller. Connecting both ends of the shield to ground may cause a ground loop. SW Adjust Adjust Output Selection Switches (SW) AC Power -0mA Out AC/DC Power 0- VDC Out Io Vin Gnd Vo DC Power -0mA Out AC/DC Power 0-0 VDC Wire Access Hole Figure # Test and Calibration Switch Settings (SW) 0% RH Output Normal Operating Condition Relative Humidity Sensor SW 0% RH Output 00% RH Output Increment RH Output Decrement RH Output Reset to Original Calibration S S Relative Humidity Temperature Sensor Temperature Sensor (Combination Unit) Figure # Figure # 0 Pleasant View Rd. Middleton Industrial Park Middleton, WI PH: (08) 8-8 FAX (08) File Name: I0000 Rev

4 + to VDC Input / to 0mA Output Supply Ground / Common + VAC Input / to 0mA Output + to VDC Supply Voltage to 0mA Output SW + VAC Supply Voltage to 0mA Output SW SW SW S S S S 0 to VDC Output + to VDC Input / 0 to VDC Output + VAC Input / 0 to 0 VDC Output 0 to 0 VDC Output Supply Ground / Common + to VDC Supply Voltage SW Supply Ground / Common + VAC Supply Voltage SW SW SW Figure # S S S S RH Test and Calibration Dip Switch Settings (See Figure #) Note: Do not adjust these switches unless you are using them to troubleshoot or recalibrate the sensor. Dipswitch # should always be left in the position. Failure to do so will not allow the RH transmitter to read the sensor (The output will always remain the same). 0% RH Output - Transmitter always outputs a signal of ma or 0 VDC. Sensor doesn t affect the transmitter output. (For Trouble Shooting Purposes Only) 0% RH Output - Transmitter always outputs a signal of ma,. VDC, or VDC. Sensor doesn t affect the transmitter output. (For Trouble Shooting Purposes Only) 00% RH Output - Transmitter always outputs a signal of 0 ma, VDC, or 0 VDC. Sensor doesn t affect the transmitter output. (For Trouble Shooting Purposes Only) Normal Operating Condition - The DIP switch must be set in this position for the RH signal to change, due to the actual measurement of the Relative Humidity by the humidity sensor. Increment RH Output - This DIP switch will allow you to calibrate the sensor through the software. The switch must be toggled from the Off to the On position and then returned to the Off position for an increase of 0.% RH. This means that if your humidity has drifted % over a certain time period, you will be able to toggle the Increment RH Output switch () times in order to slide the whole curve upward %. Note: This is only a single point calibration, and is not 0 Pleasant View Rd. Middleton Industrial Park Middleton, WI PH: (08) 8-8 FAX (08) File Name: I0000 Rev

5 recommended for critical applications. Please contact the factory before doing any field calibration. Decrement RH Output - This DIP switch will allow you to calibrate the sensor through the software. The switch must be toggled from the Off to the On position and then returned to the Off position for a decrease of 0.% RH. This means that if your humidity has drifted % over a certain time period, you will be able to toggle the Decrement RH Output switch times in order to slide the whole curve downward. Note: This is only a single point calibration, and is not recommended for critical applications. Please contact the factory before doing any field calibration. Reset to Original Calibration - Both the Increment and the Decrement DIP switches should be turned on for a minimum of seconds before turning them both off again. This will allow you to reset the transmitter back to the original factory calibration. Temperature Sensor Wiring Diagram (For RH/Temperature Combination Units only) Adjust SW Adjust Wire Access Hole + T - Setpt O/R J "After Hours" N/O Override (Dry Contact Closure) "After Hours" N/O Override (Dry Contact Closure) "After Hours" N/O Override Pushbutton (+) Temperature Sensor / Override (Short Sensor) Output to Building Automation /DDC System (-) Temperature Sensor / Override (Short Sensor) Output to Building Automation / DDC System Adjustable Setpoint Output to Controller Adjustable Setpoint Output to Controller J SW Adjustable Setpoint Actuator Override Jumper Settings (J) Override Shorts Sensor J Separate Input (Dry Contact) J Figure # Relative Humidity Sensor Relative Humidity Temperature Sensor Temperature Sensor (Combination Unit) Note: When using an AD9 or LM Temp. sensor with a current (ua) output, the (+) T terminal should be used for a + to 0VDC supply voltage and the (-) is the current output to the Building Automation or DDC System. S S Figure # Setpoint Jumper Settings (J) In Series with Sensor Separate Input J J Figure # 7 Space Mount: The RH transmitter should be placed away from areas of excessive moisture, corrosive fumes, vibration, or extremely high temperatures. The base of the housing was designed to mount over a standard X single gang junction box or flush to the wall. All of the RH sensors have a +/- % interchangeability. It is recommended to do a single point calibration for a much higher accuracy.. Mount the unit on an indoor wall, approximately to feet above the floor.. Make sure that the unit receives adequate airflow.. Connect the wires to the corresponding terminal blocks as shown in Figure # and Figure #.. Now make sure that all of the dip switches are properly set before initially powering the unit.. Now snap the cover back into position.. Finally turn out the () / Allen screws at the bottom of the enclosure until the cover cannot be removed. 0 Pleasant View Rd. Middleton Industrial Park Middleton, WI PH: (08) 8-8 FAX (08) File Name: I0000 Rev

6 Troubleshooting No reading Erratic readings are Inaccurate readings RH Conversion Formulas. Check that you have the correct supply voltage at the power terminal blocks.. Check wiring configuration and all DIP switch settings are as in Figure # and Figure #.. Verify that the terminal screws are all connected tightly and that all of the wires firmly in place. To convert transmitter output signal to %RH.. Verify that all of the wires are terminated properly.. Make sure that there is no condensation on the board.. Check that the input power is clean. In areas of high RF interference or noise, shielded cable may be necessary to stabilize signal.. If you suspect that the transmitter is not reading within the specified tolerance, please contact the factory for further assistance. -0mA to %RH Example: ma transmitter signal output (ma-ma)/ 0. = 0% RH 0- VDC to %RH Example: VDC transmitter signal output VDC/0.0 = 0% RH 0-0 VDC to %RH Example: 8 VDC transmitter signal output 8 VDC/0.0 = 80% RH 0 Pleasant View Rd. Middleton Industrial Park Middleton, WI PH: (08) 8-8 FAX (08) File Name: I0000 Rev

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

PART 1 - INTRODUCTION...

PART 1 - INTRODUCTION... Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation 1

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation 1 IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs

More information

Radiant Temperature Sensor TY7321

Radiant Temperature Sensor TY7321 AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional

More information

T7079A,B Solid State Remote Temperature Controllers

T7079A,B Solid State Remote Temperature Controllers T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature

More information

Hardware Installation Guide

Hardware Installation Guide Hardware Installation Guide Toll-free: -800-0-00 Tel. International: 0--9898 Allure EC-Sensor Series: Space temperature sensors. Product Description. General Installation Requirements The Allure EC-Sensor

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

IQ151 CONTROLLER DATA SHEET

IQ151 CONTROLLER DATA SHEET IQ151 CONTROLLER DATA SHEET The IQ151 is a controller in the Trend range with 64 inputs and 32 outputs. Full DDC (direct digital control) with PID control loops is provided. The output channels may be

More information

SLATE. Analog I/O Module INSTALLATION INSTRUCTIONS R8001U3001

SLATE. Analog I/O Module INSTALLATION INSTRUCTIONS R8001U3001 SLATE Analog I/O Module R8001U3001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

Automatic Humidifier Control SEH-7100-000

Automatic Humidifier Control SEH-7100-000 TM Automatic Humidifier Control SEH-7100-000 by Skuttle Indoor Air Quality Products Safety and Installation Instructions* INSTALLER: READ COMPLETE INSTALLATION INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

More information

TR21, TR22, TR23, and TR24 Wall Modules

TR21, TR22, TR23, and TR24 Wall Modules TR21, TR22, TR23, and TR24 Wall Modules FEATURES INSTALLATI INSTRUCTIS The TR21, TR22, TR23, and TR24 family of wall modules include: Models with setpoint adjustment. Models with humidity output. Models

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features: GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low

More information

Pressure transmitter (2 wire) / switch for continuous or On/Off Control

Pressure transmitter (2 wire) / switch for continuous or On/Off Control transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.

Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter. Installation Instructions Differential Air-pressure Transmitter Catalog Numbers 1414-IPZ10FODAA, 1414-IPZ10FNDAA, 1414-IPD10FNRAA, 1414-CPZ10FODAA, 1414-CPZ10FNDAA, 1414-CPD10PNRAA Topic Page Before Installation

More information

Y7230A CO 2 Alarm System

Y7230A CO 2 Alarm System Y7230A CO 2 Alarm System FOR CO 2 GAS DETECTION PRODUCT DATA FEATURES APPLICATION Y7230A CO 2 alarm system is used to detect gas leaking from CO 2 beverage dispensing systems and posts an alarm to occupants

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

- + +GF+ SIGNET 5075 Totalizing Monitor Instructions ENGLISH. Contents 1. Power Connections 2. Compatible Sensor Wiring

- + +GF+ SIGNET 5075 Totalizing Monitor Instructions ENGLISH. Contents 1. Power Connections 2. Compatible Sensor Wiring GF SIGNET Totalizing Monitor Instructions ENGLISH 3.0901 (B1/00) English CAUTION! Refer to this instruction manual for more details. Remove power to unit before wiring input and output connections. Follow

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

Series 510 Submersible Level Transmitters

Series 510 Submersible Level Transmitters Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting

More information

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB TB6980/TB7980 1. Introduction The TB6980/TB7980 digital thermostats provide proportional plus integral individual space temperature control in zoned commercial HVAC systems such as hydronic and pressure

More information

USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15

USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15 USER'S GUIDE Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15 PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit our Internet

More information

HD402T Pressure Transmitters

HD402T Pressure Transmitters HD402T Pressure Transmitters Sensor with high accuracy and stability Measurement of pressures relative to the atmosphere or differential pressures Dual analogue output: current and voltage Versions with

More information

Pressure Sensors. for neutral and slightly aggressive liquids and gases

Pressure Sensors. for neutral and slightly aggressive liquids and gases 1909P01 Pressure Sensors for neutral and slightly aggressive liquids and gases QBE2003-P QBE2103-P High-precision measuring Measuring range 0 to 60 bar relative Supply voltage AC 24 V / DC 12...33 V or

More information

asense CO 2 / temperature transmitter

asense CO 2 / temperature transmitter Function Description and Maintenance Instruction asense CO 2 / temperature transmitter General The IAQ-sensor product asense is used to measure indoor air carbon dioxide concentration and temperature in

More information

A99B Series Temperature Sensors

A99B Series Temperature Sensors FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors

More information

UNICOM 2500 UNICOM 2500. Installation Operation Programming. Universal Communication Converter

UNICOM 2500 UNICOM 2500. Installation Operation Programming. Universal Communication Converter User Manual UNICOM 2500 Installation Operation Programming Universal Communication Converter UNICOM 2500 Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590 Tel 516.334.0870 Fax 516.338.4741

More information

Humidity Sensor. Model HU-224/225

Humidity Sensor. Model HU-224/225 Humidity Sensor Model HU-224/225 RoHS Ultra fast response cross-linked bulk polymer capacitive sensing element Proprietary hydrophobic and oleophobic eptfe filter to protect the sensing element from condensation,

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

E 3 Point. Toxic and Combustible Gas Detector Network Platform (BACnet MS-TP, Modbus) PRODUCT SUBMITTAL ORDERING INFORMATION

E 3 Point. Toxic and Combustible Gas Detector Network Platform (BACnet MS-TP, Modbus) PRODUCT SUBMITTAL ORDERING INFORMATION E 3 Point PRODUCT SUBMITTAL Toxic and Combustible Gas Detector Network Platform (BACnet MS-TP, Modbus) ORDERING INFORMATION Single-Gas, Surface-Mount Base unit only; sensor cartridge sold separately E3SM

More information

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position

More information

Worldwide Manufacturer of Gas Detection Solutions. O 2 Transmitter ZD 21. Operation Manual

Worldwide Manufacturer of Gas Detection Solutions. O 2 Transmitter ZD 21. Operation Manual Worldwide Manufacturer of Gas Detection Solutions O 2 Transmitter ZD 21 Operation Manual Table of Contents For your safety...4 General description...4 Detection principle...5 Operational notes...5 Design...5

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

USER GUIDE. RLH 4RU Plug-in Fiber Card Housings with Optional Power Supply. Introduction. Installation. The leader in rugged fiber optic technology.

USER GUIDE. RLH 4RU Plug-in Fiber Card Housings with Optional Power Supply. Introduction. Installation. The leader in rugged fiber optic technology. USER GUIDE The leader in rugged fiber optic technology. 2013B-0830 RLH 4RU Plug-in Fiber Card Housings with Optional Power Supply NEBS LEVEL III CERTIFIED Introduction RLH 4RU Fiber Card Housings provide

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

DSL-340 MkIII Double Pass Dust Monitor Measures 0-1000mg/m 3 using DDP

DSL-340 MkIII Double Pass Dust Monitor Measures 0-1000mg/m 3 using DDP Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

PIEZOMETER AIRFLOW MEASURING RING

PIEZOMETER AIRFLOW MEASURING RING PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer

More information

2-Pair HDSL1 Adtran Fiber Optic Link System

2-Pair HDSL1 Adtran Fiber Optic Link System ISSUE 2 June 01, 2004 Data Sheet #37 2-Pair HDSL1 Adtran Fiber Optic Link System Contents 1. General. 1 2. Application... 2 3. Housings.. 2 4. Installation 3 5. Provisioning. 5 6. LED Indicators. 6 7.

More information

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections

More information

DS 1.102 DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

DS 1.102 DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches DS 1.102 02/99 AIR ROOM TEMPERATURE SENSOR with fan speed control switches Specification No. 528-X-XXX* The Active Room Temperature sensor incorporating fan speed control switches is designed to give a

More information

MTII4200 level Transmitter Installation, Operation & Maintenance Instructions

MTII4200 level Transmitter Installation, Operation & Maintenance Instructions Specialists in Liquid Level Indication MTII4200 level Transmitter Installation, Operation & Maintenance Instructions Section: M500 Bulletin: M500.31 Date: 01-26-12 Supersedes: 04-22-08 1. INTRODUCTION

More information

Relative, and differential pressure transmitter type 699

Relative, and differential pressure transmitter type 699 Relative, and differential pressure transmitter type 699 Pressure range -1... 1 mbar / 0... 0.3 50 mbar The type 699 transmitters are available in switchable pressure ranges and with or without display.

More information

Multipoint Scanning Alarm System

Multipoint Scanning Alarm System Multipoint Scanning Alarm System Many gas detection applications require multiple sensing locations to provide adequate area protection for plant personnel. Signals from a variety of field measurement

More information

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air

More information

Technical Description

Technical Description abcxyz Contents 1. General...1 2. Block Diagram...2 3. First Steps...2 4. Technical Data...3 4.1 AS-Interface...3 4.2 Pin Out...4 4.3 Supply of Periphery...4 4.4 Inputs...5 4.5 Outputs...5 4.6 Mechanical

More information

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC. 81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX

More information

T775U Series 2000 Electronic Stand-Alone Controller

T775U Series 2000 Electronic Stand-Alone Controller T775U Series 2000 Electronic Stand-Alone Controller INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The T775 electronic stand-alone controllers are the next generation of universal controls capable of remote

More information

Beck. The differential pressure transmitter for air

Beck. The differential pressure transmitter for air Beck. The differential pressure transmitter for air Differential pressure transmitter 98 General description The differential pressure transmitters of the 98 series are used to measure differential pressure,

More information

Operating Instructions. UL325 Compliant Non-monitored

Operating Instructions. UL325 Compliant Non-monitored IRB-325 Infrared Photocell UL325 Compliant Non-monitored Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment

More information

INSTRUCTION Version

INSTRUCTION Version INSTRUCTION Version 08.04.2013 BUSCOMPATIBLE TEMPERATURE SENSORS Sleeve temperature sensor HTF RS485 Teflon 2m Surface contacting temperature sensor ALTF2 RS485 Outside temperature sensor ATF2 RS485 Duct

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch User-definable Modbus/TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Save time and wiring cost with peer-to-peer

More information

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry CAMS Combustion Airflow Management System Proven solutions for a tough industry CAMS TM Combustion Airflow Management System Product Description The Air Monitor Power CAMS TM Combustion Airflow Management

More information

22.302 Experiment 5. Strain Gage Measurements

22.302 Experiment 5. Strain Gage Measurements 22.302 Experiment 5 Strain Gage Measurements Introduction The design of components for many engineering systems is based on the application of theoretical models. The accuracy of these models can be verified

More information

RSC232 Communication Converter

RSC232 Communication Converter RSC232 Communication Converter Installation and Operation Manual LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument for faulty workmanship or parts from

More information

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration Relative Humidity Measurement and Calibration The widest range of humidity products from a pioneer of RH sensor development The best in Relative Humidity technology to optimize your process Whether you

More information

Installation Guide - Alarm Module T941AM8

Installation Guide - Alarm Module T941AM8 Alarm Module T9AM Installation Guide - Alarm Module T9AM T9AM has physical inputs for connection to external alarm devices. Inputs are galvanically isolated, have transient protection, and can be programmed

More information

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY RESULT IN INJURY TO YOU OR DAMAGE TO

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

Differential Pressure Sensor

Differential Pressure Sensor 1 921 1921P01 Differential Pressure Sensor for neutral and mildly corrosive liquids and gases QBE64-DP4 Differential pressure sensor, suitable for gases or liquids, for the measurement of positive or negative

More information

POWERS CONTROL RC 195 Single Input Receiver-Controller

POWERS CONTROL RC 195 Single Input Receiver-Controller Document No. 155-119P25 RC 195-4 POWERS CONTROL RC 195 Single Input Receiver-Controller Description The RC 195 Single lnput Receiver-Controller is a pneumatic instrument which receives one pneumatic input,

More information

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. 7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND

More information

4.1. D GND D, Pins 1-3

4.1. D GND D, Pins 1-3 1. INTRODUCTION The Fiber Optic Network Extender (FONE) is designed to transmit and receive light pulses over fiber optic cable in response to INCOM communications signals. With FONE units, one INCOM master

More information

Pressure sensors for refrigerants

Pressure sensors for refrigerants 1 905 1905P02 Pressure sensors for refrigerants QBE621-PU Pressure sensor for the measurement of positive positive and negative pressure in HVAC applications with low temperature liquids or gases Piezo-resistive

More information

Temp. & humidity Transmitter Instructions

Temp. & humidity Transmitter Instructions Temp. & humidity Transmitter Instructions AQ3485/AQ3485Y www.aosong.com 1 Product Overview AQ3485/ AQ3485Y outdoor network temperature and humidity transmitter is accurate measurement of relative humidity

More information

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter Product Bulletin CD-Pxx-00-1 Code No. LIT-216525 Issued December 6, 2010 Supersedes September 12, 2008 Johnson Controls offers a complete line of Carbon Dioxide

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

Microcontroller to Sensor Interfacing Techniques

Microcontroller to Sensor Interfacing Techniques to Sensor Interfacing Techniques Document Revision: 1.01 Date: 3rd February, 2006 16301 Blue Ridge Road, Missouri City, Texas 77489 Telephone: 1-713-283-9970 Fax: 1-281-416-2806 E-mail: info@bipom.com

More information

User's Guide. Model W 3-in-1 Switching DC Power Supply

User's Guide. Model W 3-in-1 Switching DC Power Supply User's Guide Model 382260 80W 3-in-1 Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 80W 3-in-1 Switching DC Power Supply. The Model 382260 has three output ranges

More information

Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596

Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital

More information

Digital relative humidity & temperature sensor RHT03

Digital relative humidity & temperature sensor RHT03 1. Feature & Application: *High precision *Capacitive type *Full range temperature compensated *Relative humidity and temperature measurement *Calibrated digital signal 2. Description: Digital relative

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7

Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7 THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3

More information

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS EPP - 1 DECRIPTION The odel 575 is used in general water/wastewater applications. The transmitter is offered in a standard non-clogging snub nose end, flush diaphragm or protected flush diaphragm with

More information

TAC I/NETTM MR-AHU-HP. Application Specific Controller

TAC I/NETTM MR-AHU-HP. Application Specific Controller TAC I/NETTM MR-AHU-HP Both the MR-AHU and MR-HP controllers are application specific controllers (ASCs). The intention of the design is to reduce total install cost through pre-engineered control algorithms

More information

Instruction Manual. T3111 T3111L T3111P T3111Ex

Instruction Manual. T3111 T3111L T3111P T3111Ex www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

Capteur température et humidité pour HVAC

Capteur température et humidité pour HVAC Capteur température et humidité pour HVAC oct-13 Type R 590 Type R 591 Cable Pvc / Pvc Cable Silicone / Silicone Sonde de température Pt100, Pt1000, Ni1000, KTY, NTC, autres sur demande Classe B ou A Raccordement

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

RAEGuard EC FGM-13XX

RAEGuard EC FGM-13XX RAEGuard EC FGM-13XX User s Guide P/N 033-4102-000 Rev B May 2007 - READ BEFORE OPERATING - This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining,

More information

MAXIGARD A1000 SPEED SWITCH. Introduction

MAXIGARD A1000 SPEED SWITCH. Introduction A102-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 MAXIGARD A1000 SPEED SWITCH Introduction The Maxigard A1000 speed switch is designed to monitor

More information

AE8-1328 R5 March 2011. Copeland Digital Compressor Controller AE8-1328 R5. Specifications

AE8-1328 R5 March 2011. Copeland Digital Compressor Controller AE8-1328 R5. Specifications AE8-1328 R5 March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the Copeland

More information

Max-Air Technology Inc. NAMUR SOLENOID VALVE 4 and NEMA 7. Technical Data. Material

Max-Air Technology Inc. NAMUR SOLENOID VALVE 4 and NEMA 7. Technical Data. Material Technical Data Port connections Inlet and exhaust Outlet DIN connector (NEMA 4 Pictured) NAMUR SOLENOID VALVE NEMAs 4 and NEMA 7 1/4 NPT NAMUR interface 1/2" NPT Pressure Range: 30 to 150 PSI Flow factor:

More information

Mobile Data Power Model: MDP-25

Mobile Data Power Model: MDP-25 Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss

More information