SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 and 4 pole - 50 Hz

Size: px
Start display at page:

Download "SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 and 4 pole - 50 Hz"

Transcription

1 OPERATING LIMITS Flow rates up to: 24 m 3 /h Head up to: Maximum immersion depth: 62 m 12.5 m Max. particle size: Ø 5 to 8* ND discharge port: 8/1 mm IP : 68 *depending on model UVO-UCA-UCB JETSON SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 and 4 pole - 5 Hz APPLICATIONS Hm 17 UCA UVO DN8 Qm 3 /h UCA UCB DN Pumps intended for sewerage lift and discharge stations, intermittent operation. Lifting of: waste water, excess water, muddy water, industrial water. Drainage of: septic tanks, drains. AdVANTAGES - Several particle sizes: 5/7/8, several types of use depending on the type of impeller. - No risk of infiltration into the submerged motor chamber. - Completely leaktight motor part. - The cassette seal ensures reliable sealing: no bellows and no ageing through natural or chemical agents. Caracteristics - Several impeller types: VORTEX, singlechannel, two-channel. - The submerged motor cable inlet is protected 3 times against the infiltration of fluid. - Mechanical seal on the fluid side. - The UCB pumps are fitted with a block seal. UCA-UVO 28 N.T. N /ENG. - Ed.3/7-8 1

2 JETSON UVO-UCA-UCB DESIGN Hydraulic part - Submersible, vertical shaft. - Shaft common to pump and motor Oil-filled. - Interstage chamber between pump and motor, insulated by a lip seal and mechanical seals: - Double mechanical block seal for UCB pumps. - Three impeller types: single-channel, twochannel or vortex impeller. Motor - Leaktight with dry rotor. - Built-in thermal probe protecting the motor against overheating. - Direct starting up to 4 kw; Star-delta starting over 4 kw. Speed: 145 and 29 rpm Winding: ~3 ; 4 V Frequency: 5 HZ Insulation class: 155 (F) Protection index: IP 68 CE Compliance Moisture detector on models UCA 41 et UVO 28 1,5kW Option : ATEX (on certain models) IDENTIFICATION UCA /3,7 T4 CB 4 VO Range code CA: single-channel impeller CB: two-channel impeller VO: Vortex impeller number of poles Discharge diameter in cm HYDRAULIC PERFORMANCES Imp.gpm 6 Hm Qm 3 /h UCA-UVO-UCB DN8 3~4V,5Hz Ql/min Ql/s Imp.gpm 8 Hm Qm 3 /h Ql/min Ql/s UCA-UCB DN1 3~4V,5Hz 14 1 UCA-UVO 48 N UCA /3.7 T4 1 UCA /3.7 T4 2 UCA /5. T4 3 UCA /5. T4 4 UVO /1.5 T4 5 UVO /15.5 T4 6 UVO /15.5 T4 7 UVO /15.5 T4 8 UVO /15.5 T4 9 UCA-UCB 41 N UCA 41-23/6.5T4 1 UCA 41-26/1T4 11 UCA 41-28/1.T4 12 UCB 41-33/25.T4 13 UCA 41-37/25.T4 14 UCA 41-41/34.T Hft Hft Impeller diameter in cm P2 in kw T4: 4V 3~ STANDARD CONSTRUCTION Model UCA 28 UVO 28 UCA 41 UCB 41 Pump body EN-GJL 2 EN-GJL 25 EN-GJS 5-7 Impeller GGG 5 (.75) EN-GJL 2 (GG2 -.62) EN-GJL 25 EN-GJS 5-7 Shaft AISI-42 AISI-42 Mechanical seal SiC / SiC SiC / SiC Sealing on motor side NBR NBR SiC / SiC Motor frame EN-GJL 2 EN-GJL 2 EN-GJL 25 2

3 UVO-UCA-UCB JETSON DIMENSIONS UCA-UVO 28 fixed installation DN 8 mobile installation DN 8 UCA-UVO 28 A B C D E F G H1 H2 I J K L M N O P Q R UCA28-12/3.7 T UCA28-13/3.7 T UCA28-13/5. T UCA28-15/5. T UVO28-16/1.5 T UVO28-16/15.5 T UVO28-17/15.5 T UVO28-19/15.5 T UVO28-21/15.5 T TECHNICAL DATA courbe curve Submerged Installation Installation Dry sump Fonction- P1 P2 I Vitesse Speed Tension Mainsde IP Cable Weight Poids Granulométrie Particle Démarrage Starting nbr n installation immergée puisard installation sec Operation nement (kw) (kw) (A) A tr/min (rpm) réseau voltage (m) m (kg) size UCA /3.7 T4 1 + S2-15 S1 4,75 3,75 7,6 29 3~4V, 5Hz direct UCA /3.7 T4 2 + S2-15 S1 4,75 3,75 7,6 29 3~4V, 5Hz direct UCA /5. T4 3 + S2-15 S ,7 29 3~4V, 5Hz Y - UCA /5. T S ,7 29 3~4V, 5Hz Y - UVO /1.5 T S1 12,3 1,5 2,5 29 3~4V, 5Hz Y - UVO /15.5 T S1 18,6 15,5 3,5 29 3~4V, 5Hz Y - UVO /15.5 T S1 18,6 15,5 3,5 29 3~4V, 5Hz Y - UVO /15.5 T S1 18,6 15,5 3,5 29 3~4V, 5Hz Y - UVO /15.5 T S1 18,6 15,5 3,5 29 3~4V, 5Hz Y - 3

4 JETSON UVO-UCA-UCB DIMENSIONS UCA-UVO 41 fixed installation DN 1 mobile installation DN 1 UCA-UVO 41 A B C D E F G H1 H2 I J K L M N O P Q R DN UCA41-23/6.5 T UCA41-26/1. T UCA41-28/1. T UCB41-33/25. T Special Pied d assise base elbow UCB41-37/25. T set pour for UCB UCB41-41/34. T TECHNICAL DATA courbe curve Submerged Installation Installation Dry sump Fonction P1 P2 I Vitesse Speed Tension Mains IP Cable Weight Poids Granulométrie Particle Démarrage Starting n nr installation immergée puisard installation sec Operation nement (kw) (kw) (A) A tr/min (rpm) de voltage réseau (m) m (kg) size UCA 41-23/6.5T S1 8,1 6,5 13, ~4V, 5Hz Y - UCA 41-26/1.T S1 12, ~4V, 5Hz Y - UCA 41-28/1.T S1 12, ~4V, 5Hz Y - UCB 41-33/25.T S1 28, , ~4V, 5Hz Y - UCA 41-37/25.T S1 28, , ~4V, 5Hz Y - UCA 41-41/34.T S1 38, ~4V, 5Hz Y - 4

5 Yn 5 MEMO RESET AUTO UVO-UCA-UCB JETSON RECOMMENDED ACCESSORIES FOR ATEX INSTALLATIONS 1 - Gate valves 295 Gate valve DN Gate valve DN Check valve Ball check valve DN Ball check valve DN A , 5 and 14 - Electronic air pressure switch B IPAE with 1 m cable IPAE with 3 m cable IPAE with 5 m cable Cable hook for an IPAE (5) : Gate valve 2 : Ball check valve 4 : IPAE air pressure switch 5 : Cable hook for an IPAE 6 : ND 32 guide bars (ND 5 for UCB 41s) 7 : Lifting chain 9 : Control box for ATEX installations unit (YN5E) to be placed out of hazardous area 1 : Base elbow set 11 : Electrical motor cable (15m) 13 : Bleed hole to be created 14 : Zener barrier, compulsory for an ATEX installation Zener barrier (14) Chain 5 m, 6 mm thick m, 6 mm thick m, 8 mm thick (for UCB) m, 8 mm thick (for UCB) Control boxes 1 pump installation 2 pump installation Reminder: ATEX pumps are optional. Control box Reference Control box Reference UCA /3.7 T4 YN511E YN521E UCA /3.7 T4 YN511E YN521E P 1 P UCA /5. T4 YN511E YN521E UCA /5. T4 YN511E YN521E UVO /1.5 T4 YN512E YN522E I Yn 5 UVO /15.5 T4 YN5132E YN5232E UVO /15.5 T4 YN5132E YN5232E UVO /15.5 T4 YN5132E YN5232E UVO /15.5 T4 YN5132E YN5232E UCA 41-23/6.5T4 YN5116E YN5216E UCA 41-26/1T4 YN512E YN522E UCA 41-28/1.T4 YN512E YN522E UCB 41-33/25.T4 YN5155E YN5255E UCA 41-37/25.T4 YN5155E YN5255E UCA 41-41/34.T4 YN5171E YN5271E Base elbow set Base elbow set DN 8, 2 bar DN Base elbow set DN 1, 2 bar ND 32 (for UCA 41) Base elbow set DN 1, 2 bar DN 5 (for UCB 41)

6 MEMO RESET AUTO JETSON UVO-UCA-UCB RECOMMENDED ACCESSORIES FOR FIXED INSTALLATIONS Yn Gate valves Gate valve DN Gate valvedn Check valve Ball check valve DN Ball check valve DN Float switches 1 Nivo 43X1-1M ECOLO Nivo 43X1-2M ECOLO Raceway wall bracket : Gate valve 2 : Ball check valve 3 : Float switches 5 : Cable look 6 : Guide bars DN 32 (DN 5 for UCB 41s) 7 : Lifting chain 8 : Control box YN 4 or YN 5E 1 : Base elbow set 11 : Electrical motor cable (15m) 13 : Bleed hole to be created 7 - Chain 5 m, 6 mm thick m, 6mm thick m, 8 mm thick (for UCB) m, 8 mm thick (for UCB) Control boxes 1 pump installation 2 pump installation Control box Reference Control box Reference UCA /3.7 T4 YN YN UCA /3.7 T4 YN YN P 1 P UCA /5. T4 YN YN UCA /5. T4 YN YN UVO /1.5 T4 YN512E YN522E I Yn 5 UVO /15.5 T4 YN5132E YN5232E UVO /15.5 T4 YN5132E YN5232E UVO /15.5 T4 YN5132E YN5232E UVO /15.5 T4 YN5132E YN5232E UCA 41-23/6.5T4 YN5116E YN5216E UCA 41-26/1T4 YN512E YN522E UCA 41-28/1.T4 YN512E YN522E UCB 41-33/25.T4 YN5155E YN5255E UCA 41-37/25.T4 YN5155E YN5255E UCA 41-41/34.T4 YN5171E YN5271E Base elbow set Base elbow set DN 8, 2 bar DN Base elbow set DN 1, 2 bar DN 32 (for UCA 41) Base elbow set for UCB 41, 2 bar DN

7 MEMO RESET AUTO UVO-UCA-UCB JETSON ACCESSORIES RECOMMENDED FOR MOBILE INSTALLATIONS 1 - Pedestal 6 Mobile installation pedestal DN Mobile installation pedestal DN 8/1 (for UCA-UVO 28 Hmax>44m and UCA 41) Mobile installation pedestal DN 1 (for UCB) min 2 - Elbow Right elbow DN Right elbow DN : Mobile installation mounting 2 : Right elbow 3 & 4 : Quick coupling 5 : Flexible pipe 6 : Lifting chain 2 3 and 4 - Quick coupling 3) DN ) DN ) DN ) DN Flexible pipe Flexible pipe 1m DN Flexible pipe 2m DN Flexible pipe 3m DN Flexible pipe 1m DN Flexible pipe 2m DN Flexible pipe 3m DN Chain 5m, 6 mm thick m, 6 mm thick m, 8 mm thick (for UCB) m, 8 mm thick (for UCB) Control box 1 pump installation 2 pump installation Control box Reference Control box Reference UCA /3.7 T4 YN YN UCA /3.7 T4 YN YN UCA /5. T4 YN YN P 1 P UCA /5. T4 YN YN UVO /1.5 T4 YN512E YN522E I Yn 5 UVO /15.5 T4 YN5132E YN5232E UVO /15.5 T4 YN5132E YN5232E UVO /15.5 T4 YN5132E YN5232E UVO /15.5 T4 YN5132E YN5232E UCA 41-23/6.5T4 YN5116E YN5216E UCA 41-26/1T4 YN512E YN522E UCA 41-28/1.T4 YN512E YN522E UCB 41-33/25.T4 YN5155E YN5255E UCA 41-37/25.T4 YN5155E YN5255E UCA 41-41/34.T4 YN5171E YN5271E

8 JETSON UVO-UCA-UCB RECOMMENDED ACCESSORIES FEATURES Yn4 : control and protection units for 1 or 2 lifting pumps. Pump management in fixed, flooded sump or dry well installations; level monitoring and protecting of motor against overcurrents, overloads and dry running. Control unit order reference Intensity range Yn41 Yn42 in A 1 PUMP 2 PUMPS 1.6 to 5 (Yn415)43581 (Yn425) to 12 (Yn4112)43582 (Yn4212)43584 Probe management card: for S4 (I 12A). YN5E Management via microprocessor of one or two pumps in a fixed installation: flooded sump or dry well. Level monitoring and protecting of motor against overcurrents, thermal overloads and dry running. ORDER intensity range Starting REFERENCE A YN 511E ,5-1 direct YN 521E ,5-1 direct YN 519E ,3-9 Y YN 529E ,3-9 Y YN 5111E Y YN 5211E Y YN 5116E ,5-16 Y YN 5216E ,5-16 Y YN 512E Y YN 522E Y YN 5132E Y YN 5232E Y YN 5142E ,1-42 Y YN 5242E ,1-42 Y YN 5155E ,1-55 Y YN 5255E ,1-55 Y YN 5171E Y YN 5271E Y IPAE Electronic Air Pressure Switch for clear and polluted water. - Suitable for operation in an explosive atmosphere. - Suitable for draining and filling. - Complies with directive 94/9/CE (ATEX): protection against explosive atmospheres - Remote control. - Anti-deflagrating. - Insensitive to water temperature and foam. - Acid-resistant. - Undisruptable, highly accurate to within 2 cm and economical - Power supply voltage: 22V - 5 Hz. - Used with the YN 5E. For an ATEX installation use the Zener barrier (see IPAE manual for more information) NIVO43 - Ecological, mercury-free polluted water float switch. - Suitable for draining and filling, with discontactor. a) Electrical - Three-phase 4V, 5 Hz, direct-on-line starting on models 28-12/3,7 T4 and 28-13/3,7 T4. - Three-phase 4V, 5 Hz, Y starting. - Mandatory thermal protection against overcurrents via discontactor, circuit breaker or control unit with level regulator. b) Installation - Pump in vertical position, for fixed or mobile installation. - Mobile installation: the discharge port will be connected with an elbow to flexible piping with larger diameter than the pump discharge. - Dual installation: the pumps may be twinned by collector. - Check valves and valves to be installed, preferably in the upper section of the discharge duct. - Connection with flexible or rigid piping. c) Packaging - Pump supplied on a pallet - Pump supplied with electric cables H7RN-F for UCAs or NSSHOJ-S for UVO/UCB. - Accessories packaged separately. 8

Series description: Wilo-Drain TC 40

Series description: Wilo-Drain TC 40 Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site

More information

SIR 900-1100. INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES

SIR 900-1100. INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES OPERATING LIMITS Useful volume up to : L 9 L Ambient temperature : to + C Max.fluid temperature : + C* passing blade at : mm Ø Inlet dia. : mm DN Ø Outlet dia. : / Ø Vent dia.: mm Ø Cable passage : mm

More information

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR CAUTION! Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR NOTE: read the manual prior to commencement of use. For safety reasons, the pump can only be operated by

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100 CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL

More information

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. SANITARY & WASTE WATER PUMPING SYSTEMS Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. Wallace Pumps solve all those waste disposal problems, big or small, with

More information

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

Multistage high-pressure multistage centrifugal pumps

Multistage high-pressure multistage centrifugal pumps Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Fire Pump Plan Review March 2010

Fire Pump Plan Review March 2010 Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:

More information

Wilo SP Series Submersible Sump Pumps ECS. ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions

Wilo SP Series Submersible Sump Pumps ECS. ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions Wilo SP Series Submersible Sump Pumps ECS ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can

More information

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering

More information

DRS/A40-115-1.1M GRINDER. Q = Portata / Flow rate / Débit Modello l/min 75 120 180 225 240 270 Model m Modèle

DRS/A40-115-1.1M GRINDER. Q = Portata / Flow rate / Débit Modello l/min 75 120 180 225 240 270 Model m Modèle DRS/A40-115-1.1M S.C. 07/13 DRS/A40-115-1.1M CURVE DI PRESTAZIONE PERFORMANCE CURVES COURBES DE PERFORMANCE TABELLA PRESTAZIONI PERFORMANCE TABLE TABLEAU DE PERFORMANCES Q = Portata / Flow rate / Débit

More information

LC/LCD ranges level controllers

LC/LCD ranges level controllers GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice

More information

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP

400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP ERB400SWP 2 Congratulations on your purchase of a quality power tool from screwfix Direct Ltd. This product should give you reliable service but your peace of mind this power tool does carry a 12-month

More information

Vertical selfpriming Side-Channel Pumps Type WPV

Vertical selfpriming Side-Channel Pumps Type WPV Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS

More information

Series description: Wilo-Star-Z

Series description: Wilo-Star-Z H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry

More information

Installation, Operating and Maintenance Instructions

Installation, Operating and Maintenance Instructions 60 Hz 10/2014 Installation, Operating and Maintenance Instructions www.sulzer.com 2 Installation and Operating Instructions Submersible Grinder Pump Type ABS Piranha S10/4-60 S10/4-60 Ex PE25/2W-C-60 Ex

More information

1. Description. 2. List of Accessories included A B C F G H

1. Description. 2. List of Accessories included A B C F G H 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

The conditions below apply to the curves shown on the following pages.

The conditions below apply to the curves shown on the following pages. GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves

More information

Submersible pumps Grundfos With top exit Mop sump pomps Simer en City With top exit Submersible pumps Homa Submersible pumps DAB

Submersible pumps Grundfos With top exit Mop sump pomps Simer en City With top exit Submersible pumps Homa Submersible pumps DAB Submersible pumps Grundfos With top exit Mop sump pomps Simer en City With top exit Submersible pumps Homa Submersible pumps DAB Grunfos KP sump pump completely made of stainless steel.. Very effective

More information

lifting stations motralec

lifting stations motralec 3.0 lifting stations motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

PS1800 Centrifugal Pumping Systems

PS1800 Centrifugal Pumping Systems PS1 Centrifugal Pumping Systems General Data and Sizing Tables The curve show the performance range of 4 models at 1Wp solar array - irradiation of 6kWh/m² on a tilted surface - ambient temperature 3 C

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular

More information

Aludesign K A T A L O G

Aludesign K A T A L O G Aludesign K A T A L O G plynové radiátory DESIGN The result of lengthy experience and technological research, GAZELLE TECHNO today is a universally recognised gas radiator*. It has been completely re-designed

More information

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk 1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance

More information

Flygt 3068, 50Hz. Technical Specification

Flygt 3068, 50Hz. Technical Specification Flygt 3068, 50Hz Technical Specification Table of Contents Table of Contents B-pump...2 Product description...2 Motor rating and performance curves...4 C-pump...6 Product description...6 Motor rating

More information

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz VM, VMC, VMN Vertical Multistage Centrifugal Pump, 60Hz Approvals CERTIFICATE IQNet and SQS hereby certify that the organisation Swiss Pump Company AG 3645 Thun-Gwatt Switzerland Whole Company Design,

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

Installation, Operating and Maintenance Instructions

Installation, Operating and Maintenance Instructions 04/2016 EN Installation, Operating and Maintenance Instructions www.sulzer.com 2 Installation, Operating and Maintenance Instructions (Original Instructions) Submersible Grinder Pump Type ABS Piranha S10/4W-50

More information

CRK 2-130 A-W-A-BUBV 85805906

CRK 2-130 A-W-A-BUBV 85805906 GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html

More information

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES 01D351-GB FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES DOLOMIT FLOAT SWITCHES The DOLOMIT float switches find application in liquid level control in tanks and wells; they require connection

More information

Horizontal Jet Pumps 1/3-1-1/2 HP

Horizontal Jet Pumps 1/3-1-1/2 HP Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The

More information

How To Pump A Pump

How To Pump A Pump Multistage Pumps P, PVa, MP 300 Technical Data Performance range: m Capacities up to 1800m 3 /h (8800USgpm) m Head up to 300m (1000feet) m Max. speed up to 1750rpm Multistage pumps of series MP with smaller

More information

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS. Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid

More information

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz Product Catalogue ETX, Stainless steel threaded centrifugal pumps, Hz Contents Introduction... ETX... Choosing the right pump There are a wide range of pumps to select from. In order to find the right

More information

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE. SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION

More information

MODEL 300505 INSTALLATION INSTRUCTIONS

MODEL 300505 INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

SEG range 0.9 4.0 kw GRUNDFOS WASTEWATER

SEG range 0.9 4.0 kw GRUNDFOS WASTEWATER SEG range 0.9 4.0 kw GRUNDFOS WASTEWATER Grundfos SEG range Tough, versatile pumps for domestic sewage transfer In areas with no sewer systems, or areas where gravitation systems are unsuitable, pressurised

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

WATER pressure. Issue 3 / 2014. Clear water pumps for domestic and commercial applications

WATER pressure. Issue 3 / 2014. Clear water pumps for domestic and commercial applications Issue 3 / 214 WATER pressure PUMPS AND washdown transfer pumps Clear water pumps for domestic and commercial applications Email: enquiries@dlmwallace.co.nz Web: www.dlmwallace.co.nz Auckland: Maurice Road,

More information

4" SUBMERSIBLE PUMPS

4 SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant

More information

N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt

N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING Flygt The Concept N-Pump series. Bringing NEW levels of efficiency to wastewater handling applications Reduced pumping efficiency,

More information

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation

More information

How To Build A Low Voltage Capacitor Lvcp

How To Build A Low Voltage Capacitor Lvcp Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched

More information

Surface Technology. Centrifugal Fan GMD

Surface Technology. Centrifugal Fan GMD Centrifugal Fan ATEX classed adapted for paint shops Wide assortment broad area of application Service friendly low maintenance costs Headquarters: Centrifugal Fan Centrifugal Fan is a direct driven industrial

More information

In addition to the basic models, it is also possible for the units to be outfitted with add-ons.

In addition to the basic models, it is also possible for the units to be outfitted with add-ons. 1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS D R I V E S Y S T E M S PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS The vision of Iskra Avtoelektrika is to be: One of the world's leading manufacturers of electric motors and controllers for

More information

Series description: Wilo-Yonos MAXO

Series description: Wilo-Yonos MAXO 16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection

More information

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw.

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw. Compact pumps from the wastewater experts FLYGT 304, 307, 3068. Power range 0.7.4 kw. Wastewater is unpredictable, Flygt pumps are not If you want a wastewater pump that just works month after month, year

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

Direct steam injection humidifiers

Direct steam injection humidifiers Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check

More information

Flygt N-Pumps 3085, 3102 & 3127. For reliable and efficient wastewater handling

Flygt N-Pumps 3085, 3102 & 3127. For reliable and efficient wastewater handling Flygt N-Pumps 3085, 3102 & 3127 For reliable and efficient wastewater handling The Concept Flygt N-Pump series Reduced pumping efficiency, high energy and maintenance costs shouldn t be a fact of life

More information

Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1

Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1 Description NordicFlow s keep the system pressurized during normal conditions and prevent unnecessary activation of the main pump. They have compact design, high efficiency, low noise, reliable sealing

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Model 1210C Battery Powered Pump Shown. Description

Model 1210C Battery Powered Pump Shown. Description 12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information

SIGMA GROUP a. s. Divize průmyslová čerpadla

SIGMA GROUP a. s. Divize průmyslová čerpadla SIGMA GROUP a. s. Divize průmyslová čerpadla SIGMA GROUP a. s. INDUSTRIAL PUMP DIVISION Jana Sigmunda 79, 783 50 LUTÍN SEWAGE PUMPS NFPH, NFVH, NFJH, NFRH, NFPV, NFVV, NFJV, NFRV, NFPW NFVW Tel.: +420

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06 SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz

More information

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual V - JET Counteflow System V-JET Counterflow System Installation and Operation Manual 1. System Installation By purchasing the V - JET counterflow system you have obtained high-quality product, which will

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Series description: Wilo-Yonos MAXO-D

Series description: Wilo-Yonos MAXO-D ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power

More information

Project: Model: Chk d: Date: Model 32DGUII61.5S

Project: Model: Chk d: Date: Model 32DGUII61.5S Contents Model 32DGUII6.5S 32DGFU6.5S 32DGFU6.5 50DGFU62.2S 50DGFU62.2 50DGFU63.7S 50DGFU63.7 Section Page Specifications 2-38 Selection Chart 2-38 Performance Curves 2-6 Outline Drawings 2-8 Sectional

More information

Radial piston pumps type R and RG

Radial piston pumps type R and RG Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps P/N: DEF-0613A Diesel Exhaust Fluid (DEF) Pumps DEF Solutions Standard Pump has designed a range of unique, preconfigured DEF Pump Packages that are engineered to transfer AdBlue (AUS32) Diesel Exhaust

More information

Mechanical shaft seal types and sealing systems

Mechanical shaft seal types and sealing systems Chapter 2 Mechanical shaft seal types and sealing systems 1. Mechanical shaft seal types 2. Sealing systems 3. Selecting a mechanical shaft seal Mechanical shaft seal types and sealing systems 1. Mechanical

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

TIMER CONTROLLED DRAINS

TIMER CONTROLLED DRAINS TIMER CONTROLLED DRAINS FLUIDRAIN EZ-1 TEC-11 TEC-44 QUICK-SET D-LUX HIGH PRESSURE ENVIRONMENT DRAIN FLEXIBILITY SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS 190602_Timer_Drains_catalogus_2014.indd

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER System for flow measurement, data acquisition and transmission for wastewater with long battery life With Long Life Battery Open Channel Flow Meter

More information

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced

More information

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8

More information