KERN VB Version 1.3 7/2005 Operating Instructions Electronic Platform Balance

Size: px
Start display at page:

Download "KERN VB Version 1.3 7/2005 Operating Instructions Electronic Platform Balance"

Transcription

1 GB KERN VB Version 1.3 7/25 Operating Instructions Electronic Platform Balance Table of contents 1 Technical data KERN VB: Electronic platform balances 18 2 Installation of the balance Unpacking and package volume Installation 19 3 Power supply Power connection 19 4 Adjustment Entering the adjustment weight 21 5 Controls Overview of displays and indicators Overview of the keypad 24 6 Control functions Turning the balance on and off Zeroing the balance Taring Manual tare 27 7 Important information 28 8 Minor breakdown 29 9 Declaration of Conformity 3 1 Safety seal for calibration 31 VB-BA-defsi

2 1 Technical data 1.1 KERN VB: Electronic platform balances KERN VB6K2M VB15K5M VB3K1SM Readout 2 g 5 g 1 g Weighing range 6 kg 15 kg 3 kg Taring range (subtractive) 6 kg 15 kg 3 kg Adjusting weight (not included) (clase) Operating temperature 5 kg (M1) 1 kg (M1) 2 kg (M1) - 1 C C Air humidity +15% % Case (W x D x H) mm 3 x 3 x 65 Weighing plate mm 3 x 3 Weight kg (net) 7 kg KERN VB3K1M VB6K2M VB15K5M Readout 1 g 2g 5g Weighing range 3 kg 6 kg 15 kg Taring range (subtractive) 3 kg 6 kg 15 kg Adjusting weight (not included) (clase) Operating temperature 2 kg (M1) 5 kg (M1) 1 kg (M1) - 1 C C Air humidity +15% % Case (W x D x H) mm 38 x 38 x 9 Weighing plate mm 38 x 38 Weight kg (net) 1 kg 18 VB-BA-defsi-413

3 KERN VB3K1M VB6K2LM VB15K5LM Readout 1g 2 g 5 g Weighing range 3 kg 6 kg 15 kg Taring range (subtractive 3 kg 6 kg 15 kg Adjusting weight (not included) (clase) Operating temperature 2 kg (M1) 5 kg (M1) 1 kg (M1) - 1 C C Air humidity +15% % Case (W x D x H) mm 48 x 48 x 96 Weighing plate mm 48 x 48 Weight kg (net) 21 2 Installation of the balance 2.1 Unpacking and package volume Remove the balance from the packing materials carefully, take off the plastic cover and set up the balance at the work site. Keep all packing materials for future transport of the balance. Standard accessories: KERN VB Balance (mounted platform and terminal) Instruction manual Voltage adapter 2.2 Installation Set the balance on a stable surface Make sure the balance is level by adjusting the foot screws until the air bubble (at the left front of the body) is inside the circle. 3 Power supply 3.1 Power connection Connect the power supply (12-18 Vdc) with the connection cable to the balance. Connect the power supply to the mains VB-BA-defsi

4 4 Adjustment The adjustment weight can be used to check and adjust balance precision at any time. Adjustment weights can be acquired from KERN as an optional component. To decide which adjustment weights are required, refer to Chapter 1 Technical Data. Adjustment procedure Note! In calibrated apparatus, the adjustment switch can only be accessed by destroying the safety seal (first unscrew the terminal from the platform resp. the stand). This would void the calibration. Check that the surrounding conditions are stable, see Important instructions. A short warm-up time of about 1 minute is recommended for stabilisation. Remove the 6 screws below the display and keypad unit, as shown in the figure. Screws Safety seal for calibration Place the top of the display and keypad unit toward one side. Turn the switch ON as shown in the figure Screws OFF ON 2 VB-BA-defsi-413

5 4.1 Entering the adjustment weight Display Requirements: Turn the adjustment switch ON 1 Hold the key down and TARE TARE press the keys Press the key until the following values appear on the Display (depending on model): Confirm with the key Use the and keys to enter the maximum balance load (Max) (see table) VB6K2M 2 VB15K5M 5 VB3K1SM 1 VB3K1M 1 VB6K2M 2 VB6K2LM 2 VB15K5M 5 VB15K5LM 5 VB3K1M 1 VB6K2M 6 VB15K5M 15 VB3K1SM 3 VB3K1M 3 VB6K2M 6 VB6K2LM 6 VB15K5M 15 VB15K5LM 15 VB3K1M 3 Confirm with the key : 1, Use the and keys to select the adjustment weight size used (e.g., 1 kg), see Chapter 1 Technical Data. VB-BA-defsi

6 Remark: You should select adjustment weights above 3% of the maximum load. : 1, Confirm with the key CAL Confirm with the key Confirm with the key, the zero point is adjusted. Wait until CAL SP appears on the display.. Place the adjustment weight on the balance plate. CAL SP Confirm with the key TARE An internal control number that does not correspond to the weight will appear Confirm by pressing the key. The balance will exit the adjustment operation. Turn the adjustment switch OFF. Turn the switch OFF again. Replace the keypad cover and secure with 6 screws. Check that the balance is properly set by placing the 1/3 weight, then 2/3 weight and finally the total weight on the balance. Balance precision should be checked regularly when using the balance for qualityrelated applications. 22 VB-BA-defsi-413

7 5 Controls 5.1 Overview of displays and indicators, Stability indicator Lights when the weight is stable. Zero indicator Set the weight indicator to zero. Net Net indicator Lights when the tare is stored. VB-BA-defsi

8 5.2 Overview of the keypad TARE O N OFF O N OFF ON/OFF button Zeroing key TARE Tare key Digit selection key for manual tare entry. Number selection key for manual tare entry. 24 VB-BA-defsi-413

9 6 Control functions 6.1 Turning the balance on and off 1. To turn the balance on, press the ON/OFF key The balance will perform a self-test. 2. Once the weight appears on the Display, the balance is ready for weighing. kg 8,8,8,8,8, , 6.2 Zeroing the balance Due to environmental influences, the balance may not display exactly ". even when the weighing plate is empty. Nevertheless, you can zero the balance display at any time to ensure that weighing actually starts at zero. Zeroing with some weight on the balance can only be done within a certain range, depending on type. If the balance does not allow zeroing with the weight on the plate, the weight is out-of-range. 1. If the balance does not display zero exactly even when the weighing plate is empty, press the Zeroing key and the balance will start reinitialising at zero. 2. After a brief wait, the balance will be set to zero., kg VB-BA-defsi

10 6.3 Taring The weight of the containers used for weighing can be tared by pressing a button, such that the net weight of the item being weighed is displayed in subsequent weighing operations. kg 1. Place the empty container to be tared on the weighing plate. The total weight of the container will be displayed.,28 2. Press the TARE key to start the tare operation.,28 3. After taring is finished, zero is displayed along with the NET symbol that indicates net weight. The balance is ready to be used., Note: The balance can only store one tare value. When the balance is empty, the stored tare value will be displayed with a negative sign. To clear the stored tare value, empty the weighing plate and then press the TARE key. 26 VB-BA-defsi-413

11 6.4 Manual tare kg 1. If the numeric value of the tare is known (e.g.,.28 kg), use the selection keys to enter this value.,, 2. Use the digit selection key to select the initial figures for tare entry. The selected figure will blink., 8 3. Use the number selection key to select the necessary number value. 4. Follow these steps to enter the entire number (e.g.,.28 kg).,28 5. Press the TARE key. The tare will be stored. -,28 VB-BA-defsi

12 7 Important information Electronic balances are precision instruments. Avoid disturbing environmental conditions such as air current, vibrations and rapid change of ambient temperature. When necessary readjust the balance upon temperature adaptation. When appearing strong magnetic fields deviations are possible. Avoid high humidity, vapours and dust as the balance is not hermetically sealed. Do not let the balance come into direct contact with liquids, as these could enter the measuring cell. Therefore please wipe the unit with a dry or damp cloth. Do not use solvents, because varnished or plastic parts could be damaged. A short warming up time of some minutes after having switched on the balance will stabilize the measuring values. Place the object carefully on the weighing plate. Avoid any constant load on the weighing plate beyond of the use. Avoid by all means shocks and extreme impairments. Remove any spilled product immediately. When the program cycle is disturbed, switch off the balance and then turn on it again, Start again the weighing procedure. Do not use the balance in rooms where is a danger of explosion. The serial version is not explosion-proof. Check the balance regularly using external adjusting weights. 28 VB-BA-defsi-413

13 8 Minor breakdown Breakdown Possible causes No indication. Balance is not switched on. The power connection is cut off (power cable is defective or not properly inserted). Power cut. Weight indication is changing Permanently Air movements Table/Floor vibrations The pan is in contact with an alien foreign particle. Weighing result is obviously faulty The balance display is not zero The adjusting is no longer correct Temperature deviations. If any other error messages appear turn off the balance and on again. When the error message still appear please contact the manufacturer. VB-BA-defsi

14 9 Declaration of Conformity Declaration of Conformity The non-automatic electronic platform balances Type: KERN VB6K2M KERN VB15K5M KERN VB3K1SM KERN VB3K1M KERN VB6K2M Certificate no. for tests relating to the authorisation of EC construction type: Test centre: KERN VB15K5M KERN VB3K1M KERN VB6K2LM KERN VB15K5LM T 5783 NMI Are in accordance with the model described in the type-approval certificate and the requirements of the following EC directives: EC Directive relating to balances EC EMC directive Version 9/384/EWG Version 89/336/EWG Compatible norms are, in particular EN 4551 EN 5522 This declaration shall be valid only if accompanied by a certificate of conformity issued by a stated centre If a change is made to the above mentioned appliances without consulting KERN this declaration will become invalid. Date: 15. January 21 Signed: Gottl. KERN & Sohn GmbH Management Gottl. KERN & Sohn GmbH, Ziegelei 1, D Balingen-Frommern, Tel /9933-, Fax / VB-BA-defsi-413

15 1 Safety seal for calibration Safety seals (self-sticking seal (B) or lead (A)) VB-BA-defsi

Operating instructions Platform/floor scales

Operating instructions Platform/floor scales KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN

More information

The Analytical Balance

The Analytical Balance Chemistry 119: Experiment 1 The Analytical Balance Operation of the Single-Pan Analytical Balance Receive instruction from your teaching assistant concerning the proper operation of the Sartorius BP 210S

More information

Antenna Splitter ASA 1. Instruction manual

Antenna Splitter ASA 1. Instruction manual Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...

More information

804 Ti Stand. Manual 8.804.8001EN

804 Ti Stand. Manual 8.804.8001EN 804 Ti Stand Manual 8.804.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com 804 Ti Stand Manual 8.804.8001EN 06.2010 ek Teachware

More information

OCSM Series. High Resolution Digital Crane Scale. User Guide

OCSM Series. High Resolution Digital Crane Scale. User Guide OCSM Series High Resolution Digital Crane Scale Content 1. Safety Guide... 1 2. Features... 1 3. Specifications... 2 4. Capacity... 3 5. Display & Keys... 3 Scale & Remote Keys... 3 Indicators... 4 Message...

More information

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION Calibration Guide PREPARATION Adventurer Pro Adventurer Pro balances have two calibration methods: Span and Linearity. Some models have Internal Calibration (InCal ) for Span calibration. Ensure that the

More information

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG Safety precautions Safety precautions The DSL modem alpha DSL WTM EG complies with the European norm EN60950 safety of information technology

More information

Model UT713 OPERATING MANUAL

Model UT713 OPERATING MANUAL Model UT713 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Introduction Unpacking Inspection Safety Information Turning the Calibrator On Simulating a Thermocouple Measuring a Thermocouple Simulating TC

More information

Operating Manual Electronic Wheelchair Scale with cable display M50610

Operating Manual Electronic Wheelchair Scale with cable display M50610 Operating Manual Electronic Wheelchair Scale with cable display M50610 ADE GmbH & Co. Hammer Steindamm 27 29 D 22089 Hamburg Germany +49(40)432776-0 Fax +49(40)432776-10 E-mail: info@ade-hamburg.de Contents

More information

SATEX SA 230. - Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND

SATEX SA 230. - Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND - Manual SATEX SA 230 PRECISION BALANCE Weegtechniek holland b.v. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND Tel. + 31 36 522 20 30 Fax. + 31 36 522 20 60 Email info@satex.nl Website www.satex.nl page

More information

BW-500 BED WEIGHER USER MANUAL

BW-500 BED WEIGHER USER MANUAL BW-500 BED WEIGHER USER MANUAL 0 1 TABLE OF CONTENTS SPECIFICATION... 3 Equipment... 4 INSTALLING WEIGH BEAM... 5 PREPARATION FOR MEASUREMENT... 6 DP3800 Indicator... 8 POWER SUPPLY... 8 PANEL... 9 KEY

More information

Model 349KLX Remote Display Digital Scale User Instructions

Model 349KLX Remote Display Digital Scale User Instructions Model 349KLX Remote Display Digital Scale User Instructions P/N UM349KLX Rev 3-080713 1 Model 349KLX Thank you for your purchase of this Health o meter Professional product. Please read this manual carefully,

More information

CELO5. User & Installation Manual. www.audac.eu

CELO5. User & Installation Manual. www.audac.eu CELO5 User & Installation Manual www.audac.eu 2 Introduction 5 High-end Slim Ceiling Speaker The CELO5 is the 5 version of AUDAC s CELO High-end Slim ceiling speaker series with an RMS power of 50 Watt

More information

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS Safety precautions Safety precautions The DSL modem alpha DSL WTM HS complies with the European norm EN60950 safety of information technology

More information

WSD130 SOLDERING STATION

WSD130 SOLDERING STATION NOTES S2032ACH 8/98 Rev. 11/01 WSD130 SOLDERING STATION 1. Power Switch 2. Digital Display 3. UP Button 4. DOWN Button 5. Optical Regulator, Right 6. Connection for Soldering Iron, Right 7. Selection Switch

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI American Weigh Scales, Inc. CQ-Series Digital Pocket Scale 7 4 1 0. 8 9 5 6 2 3 x = - CALI + CALC MODE M CAL AC CE % TARE OFF ON MC MR CQ-350 (350x0.1g) CQ-500 (500x0.1g) User Manual CQ-Series Manual Thank

More information

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso SevenEasy Conductivity Italiano Español Français Deutsch English Contents Contents Page 1. Introduction...

More information

Thermocouple Thermometer Models

Thermocouple Thermometer Models Technology Made Easy... Thermocouple Thermometer Models 60010-00 (Type J) 60010-10 (Type K) 60010-20 (Type T) 68X309905 Rev 1 04/04 TABLE OF CONTENTS 1. INTRODUCTION 4 2. SAFETY PRECAUTIONS 6 3. SPECIFICATIONS

More information

Quick Guide. Precision Balances XS models

Quick Guide. Precision Balances XS models Quick Guide XS models Table of Contents Introduction 5 Safety Information 6. Definition of signal warnings and symbols 6. Product safety information 6 3 Design and Function 8 3. Overview 8 3.. S weighing

More information

OCS-S High Resolution Digital Crane Scale

OCS-S High Resolution Digital Crane Scale OCS-S High Resolution Digital Crane Scale Content 1. Safety Guide... 1 2. Features... 1 3. Specifications... 2 4. Capacity... 2 5. Dimension & Weight... 3 6. Display & Keys... 4 Scale Keys... 4 Indicators...

More information

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP-2004-12 ver.1.0

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP-2004-12 ver.1.0 HIGH PRECISION BALANCE MWP OWNER S MANUAL MWP-2004-12 ver.1.0 INTRODUCTION------------------------------------------------1 1. INSTALLATION---------------------------------------------------2 Unpacking---------------------------------------------------------------2

More information

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01 Milwaukee Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: SM600 Smart DO Meter Authorized Dealer: ISMIL600 11/01 PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery

More information

XP Series Balances Operation Manual

XP Series Balances Operation Manual XP Series Balances Operation Manual North and South America: 6542 Fig Street Arvada, Colorado 84 1-8-321-1135 Tel: 33-431-7255 Fax: 33-423-4831 U.K. and Ireland: Denver House, Sovereign Way Trafalgar Business

More information

Product Information Sheet UH28CS-12kV Hi Pot Tester

Product Information Sheet UH28CS-12kV Hi Pot Tester Product Information Sheet UH28CS-12kV ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet:

More information

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:

More information

MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W

MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the

More information

User manual. Videomatic VERDE MF

User manual. Videomatic VERDE MF User manual Videomatic VERDE MF EN Contents Product information.......................................... 6 I. General information....................................... 6 Notes on the electromagnetic

More information

SR 801. DK... Digitalvægt... 2 GB... Digital Scale... 7 D... Digitalwaage... 12 S... Digitalvåg... 17 U.S.A. and countries outside the EU...

SR 801. DK... Digitalvægt... 2 GB... Digital Scale... 7 D... Digitalwaage... 12 S... Digitalvåg... 17 U.S.A. and countries outside the EU... SR 801 DK.... Digitalvægt.......................... 2 GB.... Digital Scale......................... 7 D...... Digitalwaage....................... 12 S...... Digitalvåg.......................... 17 U.S.A.

More information

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall

More information

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, UK. Tel: +44 (0)1527 406800 Fax:

More information

CYMAQ Marking System AS200 + DS7050 N-14

CYMAQ Marking System AS200 + DS7050 N-14 CYMAQ Marking System AS200 + DS7050 N-14 Serial Number: 13716 CYMAQ www.cymaq.com INDEX 1. PRESENTATION AND GENERAL POINTS 1.1. General Points 1.2. Identification plate 2. MACHINE CHARACTERISTICS 2.1.

More information

My Weigh Ultraship Series User Manual

My Weigh Ultraship Series User Manual My Weigh Ultraship Series User Manual Low Batteries, bad battery connections & Faulty AC Adaptors are the #1 cause of Ultraship malfunction and inaccuracy! We test all of our scale returns from consumers.

More information

ELECTRONIC COUNTING SCALE. Operation Manual. l JCS- A SERIES

ELECTRONIC COUNTING SCALE. Operation Manual. l JCS- A SERIES ELECTRONIC COUNTING SCALE Operation Manual l JCS- A SERIES CONTENTS I. Specification:... II. Operation:... III. Weight calibration:... IV. RS232 transmission confer Data format (optional) V. Regular trouble

More information

Retail Scale bc: be connected be successful

Retail Scale bc: be connected be successful User Guide Retail Scale bc: be connected be successful User Guide Mettler-Toledo (Albstadt) GmbH ME-2201 5885H Printed in Germany 0211/2.11 Contents Contents 1. Introduction 1.1 Declaration of Conformity...1

More information

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances Operating Instructions MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances 15043 1/1.00 10 9 8 1 7 6 1 Display 2 Slider switch cd/m² segment test 3 ON/OFF switch 4

More information

Hand-held thermometer Model CTH7000

Hand-held thermometer Model CTH7000 Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference

More information

TIG INVERTER INSTRUCTION MANUAL

TIG INVERTER INSTRUCTION MANUAL TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4

More information

W850. Maintenance Guide

W850. Maintenance Guide W850 Maintenance Guide August 2011 www.lexmark.com Contents...3 Cleaning the exterior of the printer...3 Storing supplies...3 Conserving supplies...3 Checking the status of supplies...4 Checking the status

More information

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales Installation information METTLER TOLEDO MultiRange Floor scales / Pit scales KC300/KCS300 KC600/KCS600 KD600/KD1500 KE1500/KE3000 KES1500/KES3000 KG3000/KG6000 KN1500 Floor scales / Pit scales Contents

More information

1. SAFETY INFORMATION

1. SAFETY INFORMATION RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter

More information

Phoenix Body Fat Scale Manual

Phoenix Body Fat Scale Manual Phoenix Body Fat Scale Manual Low Batteries & bad battery connections are the #1 cause of scale malfunction and inaccuracy! We test all of our scale returns from consumers. Fully 60% of consumer returns

More information

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES 1 TABLE OF CONTENTS POWER SUPPLY... 3 SPECIFICATIONS... 3 MAINATENANCE AND GENERAL CARE........

More information

Microwave Meter. Instruction Manual

Microwave Meter. Instruction Manual Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted

More information

EC Type-Approval Certificate UK 2943

EC Type-Approval Certificate UK 2943 UK 2943 V(0)a EC Type-Approval Certificate UK 2943 issued by the: National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Non-Automatic Weighing Instruments Regulations

More information

Instruction Manual Crane Scales PCE-HS Series

Instruction Manual Crane Scales PCE-HS Series PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

High precision counting scale. Operation Manual. l RCZ-A Series

High precision counting scale. Operation Manual. l RCZ-A Series High precision counting scale Operation Manual l RCZ-A Series TABLE OF CONTENTS I. PRECAUTIONS BEFORE USING THE SCALE 1 II. EXPLANATION OF DISPLAY SYMBOLS 2 III. KEYPAD FUNCTIONS 4 IV. OPERATIONS 5 SWITCH

More information

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184 EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49

More information

www.blackanddecker.co.uk Ireland Australia New Zealand

www.blackanddecker.co.uk Ireland Australia New Zealand www.blackanddecker.co.uk 3 2 4 5 5 6 1 7 UK Ireland Australia New Zealand 1 8 9 10 11 12 13 1 A 14 15 B 7 18 19 16 18 19 21 17 20 C D E 2 Intended use Your Black & Decker distance and space measurer has

More information

Thermistor Thermometer MODEL NO. 93210-00

Thermistor Thermometer MODEL NO. 93210-00 Thermistor Thermometer MODEL NO. 93210-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com e-mail:

More information

MagIC 6100. Installation Manual. Point of Sales Terminals TD06014B

MagIC 6100. Installation Manual. Point of Sales Terminals TD06014B MagIC 6100 Installation Manual Point of Sales Terminals TD06014B Contents Description 3 Introduction 3 Presentation of the MagIC 6100 terminal 3 Technical Data 4 Installation 5 Unpacking 5 Safety recommendations

More information

REMOTE TERMOMETER TE 219 LED USER MANUAL

REMOTE TERMOMETER TE 219 LED USER MANUAL INTRODUCTION REMOTE TERMOMETER TE 219 LED USER MANUAL Thank you for purchasing this unit with indoor thermometer, wireless thermometer sensor and radiocontrolled clock. This device is also equipped with

More information

Hygro-Thermometer + InfraRed Thermometer Model RH101

Hygro-Thermometer + InfraRed Thermometer Model RH101 User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative

More information

Rhopoint Instruments Ltd.

Rhopoint Instruments Ltd. Rhopoint Instruments Ltd. Novo-Gloss Trio Operation Manual Information in this document is subject to change without notice. 2006 Rhopoint Instrumentation Ltd. All Rights Reserved. Novo-Gloss Trio, Novo-Shade

More information

How To Use A Meter

How To Use A Meter Table of Contents Title I UT391 Product Introduction II Unpacking Inspection III Safety Instruction IV Meter Structure V Setting and Operation of Meter VI Technical specifications VII Maintenance 3 4 5

More information

Installation and safety instructions for AC/DC built-in devices

Installation and safety instructions for AC/DC built-in devices The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further

More information

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output. High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output. Modular Design for Easy, Cost Effective Maintenance. Standardized Interface Allows Interchangeable Control Modules

More information

Gebrauchsanweisung und Medizinproduktebuch User manual and medical device booklet

Gebrauchsanweisung und Medizinproduktebuch User manual and medical device booklet Gebrauchsanweisung und Medizinproduktebuch User manual and medical device booklet DE EN Quick guide For initial use (see figure page 50) Press down on the ridges of the battery cover and slide the cover

More information

Operating instructions for Electrode sharpening machine WIG 4

Operating instructions for Electrode sharpening machine WIG 4 Operating instructions for Electrode sharpening machine WIG 4 Original Please keep for further use! Kaindl-Schleiftechnik REILING GmbH D-75203 Königsbach-Stein Remchinger Str. 4 Germany Tel.: +49 7232

More information

The Bose 601 TM Series IV Direct/Reflecting Speaker System

The Bose 601 TM Series IV Direct/Reflecting Speaker System The Bose 601 TM Series IV Direct/Reflecting Speaker System Owner s Guide October 25, 2001 AM257731_00_V.pdf Customer Information Declaration of Conformity We, the offerer: Bose Corporation, The Mountain,

More information

To purchase a full bound copy of this document contact

To purchase a full bound copy of this document contact 29570 SUB Aqua Plus IQOQ document Unique Product Serial number label placed here To purchase a full bound copy of this document contact Grant Instruments (Cambridge) Ltd Shepreth Cambridgeshire SG8 6GB

More information

How To Test A Titrette And Digital Burette

How To Test A Titrette And Digital Burette Titrette and Digital Burette (all models) Testing Instructions (SOP) May 2013 1. Introduction The standard ISO DIS 8655 describes both the design and the testing of bottle-top burette. The following Testing

More information

Spetec Laminar Flow Systems. Operating Instructions

Spetec Laminar Flow Systems. Operating Instructions Spetec Laminar Flow Systems Operating Instructions 1 Spetec Laminar Flow Systems Operating Instructions Thank you for your trust in the Spetec clean room systems! Your chosen system is ideally suited for

More information

FC6 FOOT CONTROLLER OWNER S MANUAL

FC6 FOOT CONTROLLER OWNER S MANUAL FC6 FOOT CONTROLLER OWNER S MANUAL Congratulations and thank you for purchasing the KORG FC6 Foot Controller. To get the most out of this advanced instrument (?) for the longest possible time, we recommend

More information

National- Spencer Inc.

National- Spencer Inc. 9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

RAEGuard EC FGM-13XX

RAEGuard EC FGM-13XX RAEGuard EC FGM-13XX User s Guide P/N 033-4102-000 Rev B May 2007 - READ BEFORE OPERATING - This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining,

More information

ACS-3S/NEW SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL

ACS-3S/NEW SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL ACS- SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL Thank you for choosing our ACS-3S / NEW SU single/double side display electronic waterproof weighing/counting scale. The new SU

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor

CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor 7030.111 Montage-, Installations- und Bedienungsanleitung Assembly and operating instructions Foreword Foreword Dear Customer, Thank

More information

Nokia Bluetooth Headset BH-109

Nokia Bluetooth Headset BH-109 Nokia Bluetooth Headset BH-109 Issue 1.0 2 Introduction About your headset With Nokia Bluetooth Headset BH-109, you can handle calls hands-free, even when you are using two mobile devices at the same time.

More information

Leica DISTO TM D210 The original laser distance meter

Leica DISTO TM D210 The original laser distance meter Leica DISTO TM D0 The original laser distance meter Table of Contents Instrument Set-up - - - - - - - - - - - - - - - - - - - - - - - - - - Overview - - - - - - - - - - - - - - - - - - - - - - - - - -

More information

UT202A Operating Manual. Contents

UT202A Operating Manual. Contents Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols

More information

rail design 22001-22008 Operating Manual State January 2005 Rev. 0. 2005

rail design 22001-22008 Operating Manual State January 2005 Rev. 0. 2005 rail design 22001-22008 State January 2005 Rev. 0. 2005 Operating Manual Contents IV 1 Environnemental information UW 2 General information AL 3 Safety SI 4-7 Technical details TE 8 Transport TR 9 Commissioning

More information

Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394

Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394 GE Industrial Sensing 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Druck DPI 104 Digital pressure indicator User manual - K394 A1.1 A1.2 B1 1 A2 B2 2 3 4 5 6 A1.3 8 7

More information

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)

More information

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1 Operating Instuctions Shaking device SV 14 / 22 SV 29 / 45 page 1 General notes, safety notes, notes on electrical equipment and electromagnetic compatibility, as well as notes on maintenance of the unit

More information

Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements

Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction

More information

FLEXIT S4 R S6 R S7 R

FLEXIT S4 R S6 R S7 R 94111E-05 2005-10 FLEXIT S4 R S6 R S7 R User Manual Air Handling Unit Cabinet Models with Heat Recovery - Rotor Contents 1 Important Safety Instructions... 3 2 Method of Operation - System... 3 2.1 Heating

More information

USER GUIDE. Please read carefully before use. Press button to insert or remove wand. Slide wand fully into hose.

USER GUIDE. Please read carefully before use. Press button to insert or remove wand. Slide wand fully into hose. 1 Assembling your Dyson 1 2 3 Press button to insert or remove wand. Slide wand fully into hose. 4 5 6 Twist tools before locating. Wind cable around cable winders, in an anti-clockwise direction. USER

More information

=============================== WARNING

=============================== WARNING =============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that

More information

OPERATING INSTRUCTIONS FOR ELECTRODE SHARPENING MACHINE WIG 4

OPERATING INSTRUCTIONS FOR ELECTRODE SHARPENING MACHINE WIG 4 OPERATING INSTRUCTIONS FOR ELECTRODE SHARPENING MACHINE WIG 4 Original Please keep for further use! Kaindl-Schleiftechnik REILING GmbH, D-75203 Königsbach-Stein, Remchinger Str. 4 Germany Tel.: +49 7232/4001-0,

More information

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. White series

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. White series C88-VW-B UG [Update 10.05.12]_User guide 10/05/2012 09:40 Page 1 User Guide Vax Careline: (UK) 0844 412 8455 Bagless Cylinder White Get Cleaning... What s your Vax model number? (Located on the top flap

More information

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL 148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

More information

How To Use A Cell Phone On A Cellphone On A Kx-Tvm Series 2 (Kx) (Kox-Tvp) ( Kx) Series 2.5 (Kuk) Series (Kq) Series 1

How To Use A Cell Phone On A Cellphone On A Kx-Tvm Series 2 (Kx) (Kox-Tvp) ( Kx) Series 2.5 (Kuk) Series (Kq) Series 1 Model No. KX-DT321 Thank you for purchasing a Digital Proprietary Telephone (DPT). Please read this manual carefully before using this product and save this manual for future use. For more details, please

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

Accessories SUNNY REMOTE CONTROL

Accessories SUNNY REMOTE CONTROL Accessories SUNNY REMOTE CONTROL Mounting Instructions SRC20-MO-IEN121010 IMEN-SRC20 Version 1.0 EN SMA Solar Technology AG 1 Information on this Document 1 Information on this Document Validity This

More information

Operating Instructions Drill rig DRU160

Operating Instructions Drill rig DRU160 Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested

More information

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30 INSTRUCTION MANUAL FOR WB/WBS 3, 4, 5, 7, 8, 11, 14, 30 WATER BATH PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

Tassimo The Art of the Perfect Cup

Tassimo The Art of the Perfect Cup USER INSTRUCTIONS Tassimo The Art of the Perfect Cup Thank you for purchasing the Tassimo hot beverage machine. With Tassimo, you can now enjoy your favourite hot beverage any time. Rich filter coffee,

More information

Power Supply Guide Version 1.0 for D-Show

Power Supply Guide Version 1.0 for D-Show Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731

More information

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide (=7ÔWÌ) 1307.7039.62 06 Test & Measurement Quick Start Guide This Quick Start Guide describes the following converter

More information

Infrarot-Bewegungsmelder IP44

Infrarot-Bewegungsmelder IP44 Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion

More information

Turb 550 / Turb 550 IR

Turb 550 / Turb 550 IR Operating Manual ba41112e Turb 550 / Turb 550 IR Turbidity Measuring Instrument ba41112e03 04/2003 Accuracy when going to press The use of advanced technology and the high quality standard of our instruments

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510 User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

Instruction Manual Differential Pressure Transmitter

Instruction Manual Differential Pressure Transmitter DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information