1 Multi-Speed Three-Phase Induction Motors Including Motors for Fan Applications Product Catalogue

2 Multi-Speed Three-Phase Induction Motors Certificates Cantoni Motor SA ISO 0 KEMA Since September 0, Besel SA ISO 0 DQS Since July, 99 00Q Indukta SA ISO 0 KEMA Since April, 99 ISO 00 KEMA Since July, Celma SA ISO 0 Germanischer Lloyd since June, 99 QS- HH ISO 00 Germanischer Lloyd Since November, 999 EM- HH Emit SA ISO 0 Polski Rejestr Statków Sine January, 99 NC-0/00 0 0

3 Multi-Speed Three-Phase Induction Motors Cantoni Motor S.A. M. Gra yñskiego, -0 Bielsko-Bia³a, Poland tel.: + 00 fax: + 0 motor@cantonigroup.com BESEL od roku 90 od roku od roku 9 od roku EMIT od roku 9 0

4 DESCRIPTION OF THE CATALOGUE VERSION Application general industrial, centrifugal machines Duty S voltage 00V Frequency 0 Hz Ambient temperature from - C to +0 C Mounting height up to 000 m above sea level of free shaft ends Insulation class F Degree of protection IP DESCRIPTION OF THE CUSTOMIZED VERSION Different duty type Different supply voltage Frequency 0 Hz of free shaft ends Insulation class H Degree of protection IP Tropicalization Other versions per customer s specifications Motor type designation s s Operating duty Supply voltage Frequency Mounting arragements Degree of protection Special requirements ORDERING INFORMATION When placing an order, the following motor data should be given: Information concerning additional accesories e.g. Thermal protection Anticondensation heaters Vibration sensors, etc. When ordering spare parts the following data should be given: Full motor type designation including its serial number Degree of protection Mounting arrangement Name of spare part of pieces As part of our development program, we reserve the right to alter or amend any of the specifications included in this catalogue without giving prior notice. 0

5 This catalogue covers industrial squirrel cage multi- motors for general application as well as for driving centrifugal machines such as fans. Our motors are designed for long life and reliable operation in severe industrial applications. All the motors are manufactured in Quality Assurance System consistent with ISO 0. ISO0 Multi- motors can be applied where a rough grading of is acceptable. In these motors the operation at two or more fixed s is obtained by changing the magnetic poles. Multi- motors can be either single winding - Dahlander connection where ratio is to or with two separate windings where ratio other than to can be obtained. Single winding motors are designed for direct starting from the supply and are single voltage. All the motors described in the present catalogue are provided with CE mark. It means that our products are consistent with the European Union directives regarding the safety measures. In this catalogue the motors designed especially for driving centrifugal machines are marked. In these motors the power at higher is much larger than at lower. It is because the demanded for this kind of applications varies as the square of the. The other motors can be used in applications with constant requirements such as mixers, conveyors. General technical information such as type of bearings, mounting arrangements, construction is the same as for standard motors and is described in catalogue: General Purpose -Phase Induction Motors. This catalogue contains also dimensional drawings of motors. The motors covered by this catalogue comply with the IEC 00- standard as well as standards effective in other countries, consistent with IEC. IEC This catalogue describes the most widely used multi- motors. Other types - for different fixed s can be supplied according to customer s specifications. 0

6 00/000 rpm - motors designed application rotor Weight (IMB) P N n N T N N cos N I [00V] N T L/TN I L/IN T b/tn J m [HP] [rpm] [Nm] [%] [-] [A] [-] [-] [-] [kgm ] p=/ n =00/000 rpm s. Sh -/A. Sh -/AW. Sh -/B. Sh -/BW. Sh -/C. Sh 0-/A. Sh 0-/AW. Sh 0-/B 9. Sh 0-/BW 0. Sh S-/. Sh S-/W. Sh L-/. Sh L-/W. PSh L-/ ) 0, 0, 0,0 0, 0, 0, 0, 0, 0, 0,,00, 0,,,,, 0, 0, 0,09 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,, 0,,,, ,,0 0,,,,,09,0,,,,,,,,9 9,,9,,, ,,,,,,,9,, 0, 0, 0, 0, 0. 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,,, 0,,,,,, 0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,9,,,,,,,,,,,,0,,,,9,9,,,,,,,,,,,,,,,,,,,,9,, 0,0000 0,0000 0,000 0,000 0, ,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,0,9,9,,,,, 0, 0,, )- mounting and overall dimensions are the same as for Motors with Increased Output. Highest at both s, Dahlander connection Centrifugal drive, Dahlander connection W U L V U W L V W U U V L W V L U V W U V W U V W U V W L L L L 0

7 00/000 rpm - motors designed application rotor Weight (IMB) [Nm] p=/ N cos N I N [00V] [%] [-] [A] n s=00/000 rpm T L/TN I L/IN T b/tn J m [HP] [rpm] [-] [-] [-] [kgm ]. Sg 00L-/A. Sg 00L-/AW. Sg 00L-/B. Sg 00L-/BW 9. Sg M-/ 0. Sg M-/W. Sg S-/. Sg S-/W. Sg S-/WB. Sg M-/. Sg M-/B. Sg M-/W. Sg M-/WB. PSg M-/ ) 9. Sg 0M-/ 0. Sg 0M-/W. Sg 0L-/. Sg 0L-/W, 0,,,,,,,,,,,,,9,,,,,, 0 0,,,,,,,,,,,,,9 9,, 0, 9,, 0, 0,, ,,,,,,9,9,, 9,9 9, 9,, 0,,,, 9,,,9 9,,,,,9,,9,,9,9,,, 9,,,,,,9 9, 9, 9,9,,,,,,,, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0, 0, 0, 0, 0, 0, 0, 0,,,,,,,, 9, 9,,,,,,,,,,,, 9,,,, 9,,9,,,,,,,,,,,,,,,,,0,,,,,,,,,,,,,9,,,9,9,,,,,,,,,,9,,,9,,,,,,9,,,,,,,,,,,9,,,,9,,,,9,,,,,,,,,,9,, 0,00 0,00 0,00 0,00 0,09 0,09 0,09 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0,,, ) - mounting and overall dimensions are the same as for Motors with Increased Output. Highest at both s, Dahlander connection Centrifugal drive, Dahlander connection W U V W L V W L U U U V L W V L U V W U V W U V W U V W L L L L 0

8 00/000 rpm - motors designed application rotor Weight (IMB) [rpm] p=/ N cos N I N [00V] [%] [-] [A] n s=00/000 rpm T L/TN I L/IN T b/tn J m [HP] [Nm] [-] [-] [-] [kgm ] Sg 0M-/ Sg 0M-/W Sg 0L-/ Sg 0L-/W Sg 00L/ Sg 00L/ Sg S/ Sg S/ Sg M/ Sg M/ Sg 0M/ Sg 0M/ Sg 0S/ Sg 0S/ Sg 0M/ Sg 0M/ Sg M/ 9, 9,, 0 9, 9 9, 0, ,,,,,9,,9 0, ,,,,,9 9 9,, 9, 9, 9, 9 9 9, 9, 9, 9, ,9 9, 9, 9, 9 9, 9, 9 0,9 0, 0, 0, 0, 0, 0, 0,, 0,,,, ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,9,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,9,,,,,,,,,,,,, 0, 0, 0, 0, 0, 0, 0, 0,, Highest at both s, Dahlander connection Centrifugal drive, Dahlander connection V W L V W W U L U U U V W V L L U V W U V W U V W U V W L L L L 0

9 000/00 rpm - motors designed application rotor Weight (IMB) [HP] p=/ T N N cos N I N [00V] [Nm] [%] [-] [A] n s=000/00 rpm P N n N T L/TN I L/IN T b/tn J m [rpm] [-] [-] [-] [kgm ] Sh -/A Sh -/B Sh -/C Sh 0-/A Sh 0-/B Sh 0-/C Sh S-/ Sh L-/ Sh S-/W Sh L-/W Sg 00L-/A Sg 00L-/AW Sg 00L-/B Sg 00L-/BW Sg M-/ Sg M-/W 0,0 0, 0, 0, 0, 0, 0, 0, 0,0 0 0, 0, 0, 0,,,,, 0,0 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0,,0 0,,,,,9,, ,,,9 9,,,,0,,0,,,,,,,9,,0,,,, 0, ,,,0,,9,9 9,,,,,,,9,0,, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,9 0, 0,,0, 0,,,,,,,9,,9,9,,,,,,,,,,,,0,,,,,,,,,,,,,,,,,,,0,0,,,,,,,,,,9,,,,,,,,,,,,,,,,,,,,,0,,,,,,,,,,,,,,,,0, 0,000 0,0009 0,00 0,009 0,000 0,009 0,00 0,00 0,00 0,00 0,00 0,00 0,009 0,009 0,00,0,9,,,,,,,,, Two separate windings, centirfugal drive or highest at both s L L U V W U V W U V W L L 09

10 000/00 rpm - motors designed application rotor Weight (IMB) N cos N I N [00V] T L/TN I L/IN T b/tn J m [HP] [rpm] [Nm] [%] [-] [A] [-] [-] [-] [kgm ] p=/ n =000/00 rpm s Sg S-/ Sg S-/W Sg M-/ Sg M-/W Sg 0M-/ Sg 0M-/W Sg 0L-/ Sg 0L-/W Sg 0L-/ Sg 0L-/W,,,,,,,,,,, 0,, 0,,,,,,,,, 9,9, 9 9,,,, ,,,, 0, 9,,,,,9,,,,,, 9, 0 9,,,,,9,,, 9,,,, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,9 0, 0, 0, 0,,,9, 9,,,9,, 0,,9 9,9,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,9,,,,,,,,,,,,,9,,,,,,, 0,09 0,0 0,099 0,09 0,0 0,09 0,09 0,09 0,9 0, Two separate windings, centirfugal drive or highest at both s L L U V W U V W U V W L L 0

11 000/00 rpm - motors designed application rotor Weight (IMB) N cos N I N [00V] T L/TN I L/IN T b/tn J m [HP] [rpm] [Nm] [%] [-] [A] [-] [-] [-] [kgm ] p=/ n =000/00 rpm s Sg 00L/ Sg 00L/ Sg S/ Sg S/ Sg M/ Sg M/ Sg 0M/ Sg 0M/ Sg 0S/ Sg 0/ Sg 0M/ Sg 0M/ Sg M/B Sg S/ Sg M/A Sg M/A , 9, 9,,, 9, 9,, 9,, 9,, 9, 9, 9, 9, , 9, 9 9, 9, 9, 0, 0, 0,9 0, 0, 0, 0, 0, 0, 0, ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,9,,,,,,,,,,,,9,,,,,9,,,9,,,,,,,,,,,, 0, 0, 0, 0, 0, 0,,,,,,, Two separate windings, centirfugal drive or highest at both s L L U V W U V W U V W L L

12 0/00 rpm - motors designed application rotor Weight (IMB) [rpm] p=/ N cos N I N [00V] [%] [-] [A] n s=0/00 rpm T L/TN I L/IN T b/tn J m [HP] [Nm] [-] [-] [-] [kgm ] 9. Sh -/AW 9. Sh -/BW 9. Sh 0-/A 9. Sh 0-/AW 9. Sh 0-/B 9. Sh 0-/BW 9. Sh S-/ 99. Sh S-/W 00. Sh L-/ 0. Sh L-/W 0. Sg 00L-/W 0. Sg 00L-/A 0. Sg 00L-/AW 0. Sg 00L-/B 0. Sg 00L-/BW 0. Sg M-/ 0. Sg M-/W 09. Sg M-/BW 0,0 0, 0,09 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,, 0,,,, 0,0 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 9, 0,,, 0,,,, ,,,,,,,9,,9,0,,,,,9,,, 9,,,9, 9,0,, 0, 0, 0,, ,,9 9,9,,,,,,,,,,,,, 0,,,9, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 9 0, 0, 0, 0, 0, 0, 0, 0, 0,, 0,,, 0,,,,,,9,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,0,9,9,,,,,,,,,9,,,,,,,,,,,,,,,,,,,,,,,,,,,,, 0,000 0,0009 0,009 0,009 0,000 0,000 0,00 0,00 0,00 0,00 0,009 0,00 0,00 0,009 0,009 0,0 0,0 0,0,,,,,,,,,,, 9, Highest at both s, Dahlander connection Centrifugal drive, Dahlander connection U V W L V W W L U U U V W V L L U V W U V W U V W U V W L L L L

13 0/00 rpm - motors designed application rotor Weight (IMB) N cos N I N [00V] T L/TN I L/IN T b/tn J m [HP] [rpm] [Nm] [%] [-] [A] [-] [-] [-] [kgm ] p=/ n s=0/00 rpm 0. Sg S-/. Sg S-/W. Sg S-/WB. Sg M-/. Sg M-/W. Sg M-/WB. Sg 0M-/. Sg 0M-/W. Sg 0L-/ 9. Sg 0L-/W 0. Sg 0L-/. Sg 0L-/W. Sg 00L/. Sg 00L/. Sg S/. Sg S/. Sg M/. Sg M/,,,,,,,,,,,,, 0,,9, 9,,,,,,,,, 9,, 9, 9 0, ,,,,9 0,, 9,,, 0,,9,9, 9, 9, 0,, ,,, 0, 0,,,,,,, 0,,,,,,9,,,,, 9,, 9 9, 9, 9,, 9, 9, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,,9,, 9,, 0,, 0,,, 9,,, 9,, 9, 0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,9,,,,,,,,,,,,,,,,,,,,9,,,9,,,,,,,,,,,,,,,,,,, 0,09 0,0 0,0 0,099 0,0 0,0 0,0 0,0 0,09 0,09 0, 0, 0, 0, 0, 0, 0, 0, Highest at both s, Dahlander connection Centrifugal drive, Dahlander connection Two separate winding, centrifugal drive V W L V W W U L L U V W L U U U V L W V L U V W U V W U V W U V W U V W U V W L L L L L L

14 0/00 rpm - motors designed application rotor Weight (IMB) [rpm] p=/ N cos N I N [00V] [%] [-] [A] n s=0/00 rpm T L/TN I L/IN T b/tn J m [HP] [Nm] [-] [-] [-] [kgm ]. Sg 0M/ 9. Sg 0M/ 0. Sg 0S/. Sg 0S/. Sg 0M/. Sg 0M/. Sg M/. Sg M/A. Sg M/B. Sg M/C. Sg M/C 9. Sg M/C 0. Sg M/C. Sg S/. Sg S/. Sg M/A. Sg M/A. Sg M/B. Sg M/B. Sg L/. Sg L/ ,,, 9, 9 9,, 9, 9 9, 9 9, 9, 9, , 9, 9, 9, 9, 9, 9 9, 9 9, 9, 9, 9 9,9 9, 9 9, 9 9, 9, 9, 9, 9,9 9, 9,9 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,9 0,9 0,9 0, 0,9 0, 0, 0, 0, 0, 0, 0, ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,0,,,,,,,,,,,9,,9,,,,,,,,,,,9,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Highest at both s, Dahlander connection Centrifugal drive, Dahlander connection U W V W L V W L U U U V W V L L U V W U V W U V W U V W L L L L

15 0/000 rpm - motors designed application rotor Torque Weight (IMB) N cos N I N [00V] T L/TN I L/IN T b/tn J m [HP] [rpm] [Nm] [%] [-] [A] [-] [-] [-] [kgm ] p=/ n s=0/000 rpm 9. Sh S-/W 0. Sh L-/W. Sg 00L-/AW. Sg 00L-/BW. Sg M-/. Sg M-/W. Sg S-/W. Sg M-/AW. Sg M-/BW. Sg 0L-/ 9. Sg 00L/ 0. Sg S/. Sg M/. Sg 0M/. Sg 0S/. Sg 0M/. Sg M/. Sg M/A 0, 0, 0, 0, 0,0,,,,,,0, 0 0 0, 0, 0, 0, 0, 0,,,,,9,0,,, 0, ,,9,,,0 9,,00,,9, 0,0,0, ,,,,,, 9,,,,, 9 9,9 9, 0,,,,,, , 9, 9 0, 0, 0,9 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,9 0,9 0, 0,9 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,,,,,,9,,,,9,,,, 9,,,,,,,, ,,,,,,,,0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,9,,,,,,,9,,,,9,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, 0,00 0,00 0,00 0,009 0,0 0,0 0,0 0,0 0,00 0, 0, 0,,,, 9,,,,9, Two separate windings, centirfugal drive or highest at both s L L U V W U V W U V W L L

16 00/000 rpm - motors designed application rotor Weight (IMB) N cos N I N [00V] T L/TN I L/IN T b/tn J m [HP] [rpm] [Nm] [%] [-] [A] [-] [-] [-] [kgm ] p=/ n =00/000 rpm s. Sg M-/W. PSg M-/ 9. Sg 0M-/ 0. Sg 0L-/. Sg S/. Sg M/. Sg 0S/. Sg 0M/. Sg M/. Sg M/C. Sg M/A. Sg M/B 9. Sg M/B 0,,,,,,, ,,,,,,, 0, ,9,, 0,,,,0, ,,, 0,,, 0,, 0, 9, 9, 9,, 9, 9 9, 9, 9 9, 9, 9,9 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,,,, 9,,,,,,, 00, 99 0,9,,,,,,,,,,,,,,,,,0,,,9,,,,,,,,,,,,,,,,,,,,,,,,0,,,,,,,,,,,,,,,,,,,, 0,0 0,0 0,0 0,09 0, 0,,,, 9, Highest at both s, Dahlander connection Centrifugal drive, Dahlander connection U W V W L V W L U U U V W V L L U V W U V W U V W U V W L L L L

17 Three-Speed Motors 000/00/000 rpm 0/00/000 rpm rotor Weight (IMB) N cos N I N [00V] T L/TN I L/IN T b/tn J m [HP] [rpm] [Nm] [%] [-] [A] [-] [-] [-] [kgm ] p=// n s=000/00/000 rpm 0. Sg 0M-//. Sg 0L-//,,,,,, 0,, , 0,,,,,, 0,,,, 0,9 0, 0,9 9,,,,, 0,,,,,,,,,,,,,, 0,0 0, Sg S-//. Sg 0M-//. Sg 0L-// L Medium V,,,,,, 9, U W,9,,, 9, 9,9 p=// L 9,, 9,,,, 9,,9 V U W n =0/00/000 rpm s 000/00/000 rpm: two separate windings, medium / high - Dahlander connection, highest at all s,, 9,,, 0, 0, 0, 0, 0, 0,,9,,,, 0,,,,,,,,,9,9,,,,,,,,,,,9 0,0 0,0 0, V W L U V U W U V W U V W U V W U V W U V W U V W L L L 0/00/000 rpm: two separate windings, low / medium - Dahlander connection, highest at all s Medium L V W L V W U V W L U U U V W U V W U V W U V W U V W U V W L L L

18 Three-Speed Motors 0/000/00 rpm rotor Weight (IMB) [HP] [rpm] p=// T N N cos N I N [00V] [Nm] [%] [-] [A] n s=0/000/00 rpm P N n N T L/TN I L/IN T b/tn J m [-] [-] [-] [kgm ]. Sg S-//. Sg M-//. Sg 0M-//. Sg 0L-// 9. Sg 0L-//. Sg 00L// 9. Sg S// 9. Sg M// 9. Sg 0M// 9. Sg 0S// 9. Sg 0M// 9. Sg S//,,,9,,,,,9,, ,,,,,,,,,9 9, , 9, 0,,9,,,,,,,, 0,, ,,,,, 9, 9,,,,,,,,, , 9, 9 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,9 0, 0, 0, 0, 0,,9,,,, 9, 0,, 9,9 9,,, ,,,,,,,,,,,,,,,,,,,,,,,,,,,,9,,,9,,,,,9,,,,,,,,,,,,,,,,9,,,,,,,,,,9,,,,,,,9,,,,,,,,,,,,,,,,, 0,09 0,099 0,0 0,09 0, 0, 0, 0,,,, Two separate windings, low / high - Dahlander connection, highest at all s V W Medium L U V W L V W V W Medium U L V W L U U L U V L W U U V W U V W U V W U V W U V W U V W U V W U V W U V W U V W U V W U V W L L L L L L

19 Four-Speed Motors 00/00/000/00 rpm rotor Weight (IMB) 9. Sg 0M-/// 9. Sg 0L-/// 99. Sg S/// 00. Sg S///,,,9,,,9, 9 Medium-lower N cos N I N [00V] T L/TN I L/IN T b/tn J m [HP] [rpm] [Nm] [%] [-] [A] [-] [-] [-] [kgm ] p=/// n s=00/0/000/00 rpm,,,,,,, 9 0, Two separate windings, highest at all s, low / medium-higher - Dahlander connection, medium-lower / high - Dahlander connection,,,,,,, 9 Medium-higher,, 9,, 9,,,,,,, 9 9 0, 0, 0, 0, 0,,,, 9, 9, 0, 0, 9 9,,,,,,,,,,,,,,,,9,,,,,,,,,,,,,,,,, 0,0 0,09 0,, U U V W V W L V W L V W L U V W L U U V U W U V W U V W U V W U V W U V W U V W U V W U V W U V W U V W U V W U V W L L L L Performance data placed on rated plates of the motors may be different from catalogue data as a result of number roundings. 9

20 CANTONI MOTOR S.A. M. Gra yñskiego -00 Bielsko-Bia³a, Poland tel fax + 0 motor@cantonigroup.com 0/WBF-EN/0_009

We will discuss common industrial applications with guides for the proper use of electric motors on these.

We will discuss common industrial applications with guides for the proper use of electric motors on these. INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES

THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES IE2 FRAMES 80 355 0,75 315kW (1500rpm) FOR INVERTER DUTY Code Declaration of conformity The motors described in this catalogue satisfy the essential

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

Data Sheet. AC Industrial Electric Motors

Data Sheet. AC Industrial Electric Motors Data Pack B Issued ovember 2005 1502325812 Data Sheet AC Industrial Electric Motors Standards organisations The RS-ABB range of ac induction motors is produced to common European standards, these being

More information

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

SIMOTICS Low-Voltage Motors

SIMOTICS Low-Voltage Motors SIMOTICS Low-Voltage Motors 'LVWULEXWLRQ RIIHULQJ 7KLV WHFKQLFDO EURFKXUH IRFXVHV RQ D VHOHFWHG PRWRU VSHFWUXP VSHFLILFDOO\ GHILQHG IRU WKH GLVWULEXWLRQ EXVLQHVV FRYHULQJ DOO PDLQ VWDQGDUG DSSOLFDWLRQV

More information

1 Temperature Derating Guide

1 Temperature Derating Guide VLT HVAC Drive FC 02 Application Note Temperature Derating Guide Temperature Derating Guide.. Abstract This paper provides detailed data regarding the operation of the VLT HVAC Drive FC02 at varying ambient

More information

Unit 33 Three-Phase Motors

Unit 33 Three-Phase Motors Unit 33 Three-Phase Motors Objectives: Discuss the operation of wound rotor motors. Discuss the operation of selsyn motors. Discuss the operation of synchronous motors. Determine the direction of rotation

More information

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS D R I V E S Y S T E M S PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS The vision of Iskra Avtoelektrika is to be: One of the world's leading manufacturers of electric motors and controllers for

More information

OJ L 191, 23.7.2009, p. 26. OJ L 2, 7.1.2014, p. 1.

OJ L 191, 23.7.2009, p. 26. OJ L 2, 7.1.2014, p. 1. Table of Contents 1. Purpose of the guidelines and disclaimer... 2 1.1. The Regulations... 2 2. Scope... 2 3. Historic developments... 4 4. Scope and Requirements... 5 4.1. Scope... 5 4.2. Requirements...

More information

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications The XFE Soft Starter range provides a combination of competitive prices, flexible

More information

D.C. Motors. Products and specifications subject to change without notice.

D.C. Motors. Products and specifications subject to change without notice. D.C. Motors Order/Technical Support - Tel: (8) 677-5 / FAX: (8) 677-865 / www.crouzet-usa.com / DC Motors Selection guide Gearbox Speed Torque max (Nm).5. Type of Gearbox 8 8 8. Power usable (w) Torque

More information

PM734F - Technical Data Sheet Winding 28

PM734F - Technical Data Sheet Winding 28 - Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including

More information

Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue

Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue Energy Saving ECM s and Fans 2010 Ventilation Catalogue CONTENTS For ellington, sustainability is about delivering products at competitive prices while preserving the environment for future generations.

More information

How the efficiency of induction motor is measured?

How the efficiency of induction motor is measured? How the efficiency of induction motor is measured? S. Corino E. Romero L.F. Mantilla Department of Electrical Engineering and Energy E.T.S.I.I. y T. Universidad de Cantabria Avda de Los Castros, 395 Santander

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-12702 This is to certify that the Electric Motor with type designation(s) RN series 56 up to 315L Manufactured by Rotor B.V. EIBERGEN, Netherlands

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

C Standard AC Motors

C Standard AC Motors C Standard AC Standard AC C-1 Overview, Product Series... C-2 Constant... C-9 C-21 C-113 Reversible C-147 Overview, Product Series Constant Reversible Electromagnetic Brake C-155 Electromagnetic Brake

More information

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated? Extra Questions - 2 1. A straight length of wire moves through a uniform magnetic field. The e.m.f. produced across the ends of the wire will be maximum if it moves: a) along the lines of magnetic flux

More information

FAN & BLOWER CENTRIFUGAL FANS

FAN & BLOWER CENTRIFUGAL FANS FAN & BLOWR CNTRIFUGAL FANS INTRODUCTION GNRAL PRODUCT RANG FANS BY FANTCH - INTRACTIV PRODUCT SUIT SLCTION PROGRAM PRFORMANC CONSTRUCTION The Fan & Blower range of centrifugal fans is marketed to the

More information

Torque motors. direct drive technology

Torque motors. direct drive technology Torque motors direct drive technology Why Direct Drive Motors? Fast and effective Direct-drive technology in mechanical engineering is defined as the use of actuators which transfer their power directly

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt. Lab 13: Wound rotor induction motor. Objective: to examine the construction of a 3-phase wound rotor induction motor; to understand exciting current, synchronous speed and slip in this motor; to determine

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP ABB The Preferred Partner Egypt Cement Corporation, a major cement manufacturer, has chosen ABB wound rotor motors for all key applications

More information

What Do All Those Things on an AC Motor Nameplate Mean?

What Do All Those Things on an AC Motor Nameplate Mean? What Do All Those Things on an AC Motor Nameplate Mean? Introduction: Ever order a motor on power, speed, and enclosure? PO says maybe "5 hp, 1,800 rpm, TEFC." New-motor nameplate says "HP 5, RPM 1748,

More information

Small Coreless DC Motors

Small Coreless DC Motors CL Series 3 to 25 W Coreless DC Motors Smooth-running, optimized-performance coreless DC motors Small Coreless DC Motors Allied Motion s CL series of small coreless DC motors provides maximized performance

More information

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR INDEX NO. : M-142 TECHNICAL MANUAL FOR NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR Manufactured by : PREMIER TRADING CORPORATION (An ISO 9001:2000 Certified Company) 212/1, Mansarover Civil

More information

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION SC ELECTROPUTERE SA SC ELECTROPUTERE SA 1. Vision, Mission, Values SC ELECTROPUTERE SA 2. LOCATION Craiova: Located in the South West of the country,

More information

BIG SAVINGS FOR A LOT MORE APPLICATIONS

BIG SAVINGS FOR A LOT MORE APPLICATIONS MSF SOFT STARTERS BIG SAVINGS FOR A LOT MORE APPLICATIONS Soft Starters from Emotron Unique features built into Emotron MSF Soft Starters reduce costs significantly for many more applications when compared

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

BMD. Permanent Magnet AC Synchronous Motors

BMD. Permanent Magnet AC Synchronous Motors BMD Permanent Magnet AC Synchronous Motors Power, control and green solutions About us 3 Bonfiglioli, one name for a large international group. It was back in 1956 that Clementino Bonfiglioli established

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) 4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact

More information

MOTOR CONTROL IS OUR NATURE

MOTOR CONTROL IS OUR NATURE MOTOR CONTROL IS OUR NATURE profile Founded in 1977, Solcon Industries Ltd. is a dynamic Power Electronics Company that develops, manufactures and manages worldwide product sales all under one roof. Our

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

Water-cooled three-phase asynchronous motors. Type series K21B / K23B

Water-cooled three-phase asynchronous motors. Type series K21B / K23B Water-cooled three-phase asynchronous motors Type series K21B / K23B Contents Page Introduction 3 Standards and regulations 4 Design version 4 Water cooling 5 Degree of protection 5 Drain holes 5 Vibration

More information

Baldor Electric Position on DOE Small Motor Rule

Baldor Electric Position on DOE Small Motor Rule Baldor Electric Position on DOE Small Motor Rule WP0035 WP0034 Page 1 of 6 US Integral DOE Small HP Motor Rule Rule Baldor Electric Position on DOE Small Motor Rule 10/28/14 On March 9, 2010 the US Department

More information

ICQ Series - square centrifugal

ICQ Series - square centrifugal product ICQ Square Centrifugal (TEFC) dimensions mm 280-710 poles & duty 4-8 / up to 4,500 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fire pumps

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

ENERGY-SAVINg DRIVE PACKAGE DE ES FR IT. Overview

ENERGY-SAVINg DRIVE PACKAGE DE ES FR IT. Overview ENERGY-SAVINg DRIVE PACKAGE SPriPM Motor & YASKAWA V1000 Inverter Drive EN DE ES FR IT Overview - Super Premium IPM Motor & YASKAWA V1000 Inverter Drive The Motor-Inverter Package was developed to support

More information

CRK 2-130 A-W-A-BUBV 85805906

CRK 2-130 A-W-A-BUBV 85805906 GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html

More information

ELECTROMAGNETIC DISC BRAKES

ELECTROMAGNETIC DISC BRAKES ELECTROMAGNETIC DISC BRAKES TYPE 66E 15/30 52.121 Hand release Lining wear adjustment Torque adjustment 4 holes ø13 DISC SIZE Ø A Braking torque Nm Regulated from (40-100%) Reaction on the shaft N Control

More information

Application Information

Application Information Moog Components Group manufactures a comprehensive line of brush-type and brushless motors, as well as brushless controllers. The purpose of this document is to provide a guide for the selection and application

More information

Introduction. Upon completion of Basics of AC Motors you should be able to:

Introduction. Upon completion of Basics of AC Motors you should be able to: Table of Contents Introduction...2 AC Motors...4 Force and Motion...6 AC Motor Construction... 12 Magnetism... 17 Electromagnetism... 19 Developing a Rotating Magnetic Field...24 Rotor Rotation...29 Motor

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60076-1 Edition 2.1 2000-04 Edition 2:1993 consolidated with amendment 1:1999 Power transformers Part 1: General This English-language version is derived from the original bilingual

More information

Motor Specifications. Nameplate

Motor Specifications. Nameplate Motor Specifications Nameplate The nameplate of a motor provides important information necessary for selection and application. The following drawing illustrates the nameplate of a sample 30 horsepower

More information

Permanent Magnet DC Motors

Permanent Magnet DC Motors typical applications Robotics and factory automation Pick-and-place robots Positioning tables Welding wire feeders Automatic guided vehicles Barcoding equipment Computer and office equipment Copier and

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

SYNCHRONOUS MACHINES

SYNCHRONOUS MACHINES SYNCHRONOUS MACHINES The geometry of a synchronous machine is quite similar to that of the induction machine. The stator core and windings of a three-phase synchronous machine are practically identical

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet HCM434F - Winding 311 Technical Data Sheet HCM434F SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards

More information

PPA & PPC series motors High specification cast iron units

PPA & PPC series motors High specification cast iron units Edition 4 Issue 3 PPA & PPC series motors High specification cast iron units Accreditation No. 14396 SOLUTIONS, not just products Specialists in Electric Motors, Geared Motors & AC Drives At CMG we offer

More information

Modelling, Simulation and Performance Analysis of A Variable Frequency Drive in Speed Control Of Induction Motor

Modelling, Simulation and Performance Analysis of A Variable Frequency Drive in Speed Control Of Induction Motor International Journal of Engineering Inventions e-issn: 78-7461, p-issn: 319-6491 Volume 3, Issue 5 (December 013) PP: 36-41 Modelling, Simulation and Performance Analysis of A Variable Frequency Drive

More information

Basic Nameplate Information

Basic Nameplate Information Basic Nameplate Information General Information: Most equipment nameplates will have some common items of information. Many of these are self explanatory, and include: Manufacturer Manufacturerʼs address

More information

Air damper actuators

Air damper actuators 4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically

More information

Offshore Platform Powered With New Electrical Motor Drive System

Offshore Platform Powered With New Electrical Motor Drive System Offshore Platform Powered With New Electrical Motor Drive System Authors: Jan O. Lamell, M.Sc E.E. ABB Automation Technologies Presenters: Thomas Johansson, M.Sc E.E. ABB Automation Technologies Timothy

More information

Electronic, Digital and Mechanical Vibration Switches

Electronic, Digital and Mechanical Vibration Switches PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive

More information

TERMINAL MARKINGS AND CONNECTIONS PART WINDING START

TERMINAL MARKINGS AND CONNECTIONS PART WINDING START TERMINAL MARKINGS AND CONNECTIONS PART WINDING START NEMA NOMENCLATURE 6 LEADS 7 7 3 9 8 Delta 3 9 8 Wye OPER. 9 MODE L L L3 OPEN 7 START 3 7,8,9 T T T3 T7 T8 T9 RUN,7,8 3,9 3 8 MOTOR LEADS 3 7 Double

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt. Lab 9: Synchronous motor. Objective: to examine the design of a 3-phase synchronous motor; to learn how to connect it; to obtain its starting characteristic; to determine the full-load characteristic of

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H. POWER SUPPLY SYSTEMS AND ELECTRICAL EQUIPMENT FOR DESALINATION PLANTS Y.M. Hamud and A.H. Anwar Abu Dhabi Water and Electricity Authority, Abu Dhabi, UAE Keywords : Electrical System, Network for Desalination,

More information

Electric Motors. Technical catalogue. Low-voltage squirrel-cage motors. 3.1 e

Electric Motors. Technical catalogue. Low-voltage squirrel-cage motors. 3.1 e Electric Motors Technical catalogue Low-voltage squirrel-cage motors 3.1 e 2002 All technical data, outputs, dimensions and weights stated in this catalogue are subject to change without prior notice.

More information

Technical Specification. Generating Set with Waukesha engine burning natural gas

Technical Specification. Generating Set with Waukesha engine burning natural gas Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the

More information

3790 en - 06.2007 / d. Alternators LSA 46.2-4 Pole. Electrical and mechanical data

3790 en - 06.2007 / d. Alternators LSA 46.2-4 Pole. Electrical and mechanical data 379 en - 6.7 / d Alternators LSA 46.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 46.2 alternator is designed to be suitable for typical generator applications, such

More information

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,

More information

SBL/K Motor Catalogue 2002

SBL/K Motor Catalogue 2002 SBL/K Motor Catalogue 2002 Brushless Servomotors up to 32Nm Motor Technology Ltd. Motec House Chadkirk Ind. Est. Romiley Stockport Cheshire SK6 3LE England Tel. +44(0)161 427 3641 Fax. +44(0)161 427 1306

More information

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

SPEED CONTROL SYSTEM

SPEED CONTROL SYSTEM SPEED CONTROL SYSTEM INDEX SPEED CONTROL MOTOR FEATURES 144 6W ( 70mm) 153 10W ( 70mm) 155 15W ( 80mm) 157 25W ( 80mm) 159 40W ( 90mm) 161 SPEED CONTROL W ( 90mm) 163 90W ( 90mm) 165 120W ( 90mm) 168 180W

More information

Principles of Adjustable Frequency Drives

Principles of Adjustable Frequency Drives What is an Adjustable Frequency Drive? An adjustable frequency drive is a system for controlling the speed of an AC motor by controlling the frequency of the power supplied to the motor. A basic adjustable

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

AC Replacement for DC Mill-Duty Motors

AC Replacement for DC Mill-Duty Motors AC Replacement for DC Mill-Duty Motors This article is available online at www.aist.org for 30 days following publication. For many years, DC mill auxiliary motors for steel mill applications such as screwdowns,

More information

S Y N C H R O N O U S G E N E R A T O R S

S Y N C H R O N O U S G E N E R A T O R S S E R I E S SYNCHRONOUS G E N E R A T O R S INDAR SYNCHRONOUS GENERATORS S E R I E S BZK INDAR ELECTRIC INDAR, EXPERIENCE AND COOPERATION INDAR Electric develops and manufactures electrical rotating machines

More information

Speed Control Relays SX2

Speed Control Relays SX2 SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................

More information

TABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...

TABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES... SYNCHRONOUS MOTORS TABLE OF CONTENTS Motores Síncronos INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...11 CONSTRUCTIVE CHARACTERISTICS...12

More information

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig Through hollow shaft Ø 5 bis 4 mm Outside diameter only 76 mm Easy installation by means of clamping ring front or rear Operating temperature up to 00 C Applications: motors, printing machines, lifts NUMBER

More information

"AC2EC" - Replacement made easy New EC motor design Compact and efficient

AC2EC - Replacement made easy New EC motor design Compact and efficient "AC2EC" - Replacement made easy New EC motor design Compact and efficient The efficiency of the fans used is a central issue in ventilation and airconditioning technology. This is encouraged not only by

More information

Fundamentals of Inverter Fed Motors

Fundamentals of Inverter Fed Motors Fundamentals of Inverter Fed Motors Technical Manual 10/02 MN780 Contents Page The Growing Use Of Inverters.................................................................. 1 How Inverters Affect Motors....................................................................

More information

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE INTRODUCTION In all kinds of manufacturing, it is very common to have equipment that has three phase motors for doing different

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

O-I DUBI PLANT FANS Quotation Spec Data & Specifications TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement

More information

Your professional Partner also for special Miniseries & special Series.

Your professional Partner also for special Miniseries & special Series. Your professional Partner also for special Miniseries & special Series. Your professional Partner also for special Miniseries and special Series. / Page 1 Company Profile ABM Greiffenberger One of the

More information

TorqPlus TM Electric Valve Actuators and Controls

TorqPlus TM Electric Valve Actuators and Controls TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

BCI184E - Technical Data Sheet

BCI184E - Technical Data Sheet BCI184E - Technical Data Sheet BCI184E SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

Know-how makes the difference. Electrical Actuators

Know-how makes the difference. Electrical Actuators Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product

More information

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range Type series booklet 8521.15/2--10 ACTELEC 31 to 800 (BERNARD) 1/4 turn electric actuators (irreversible reducer with multi -turn electric actuator ACTELEC 31: screw -nut kinematics ACTELEC 200 to 800:

More information

FREQUENCY CONTROLLED AC MOTOR DRIVE

FREQUENCY CONTROLLED AC MOTOR DRIVE FREQUENCY CONTROLLED AC MOTOR DRIVE 1.0 Features of Standard AC Motors The squirrel cage induction motor is the electrical motor motor type most widely used in industry. This leading position results mainly

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Technical Guide No. 100. High Performance Drives -- speed and torque regulation

Technical Guide No. 100. High Performance Drives -- speed and torque regulation Technical Guide No. 100 High Performance Drives -- speed and torque regulation Process Regulator Speed Regulator Torque Regulator Process Technical Guide: The illustrations, charts and examples given in

More information