Continuous Dow Corning 791 Silicone Weatherproofing Sealant cap along edge of silicone transition strip. Dow Corning Silicone Transition System (STS)

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Continuous Dow Corning 791 Silicone Weatherproofing Sealant cap along edge of silicone transition strip. Dow Corning Silicone Transition System (STS)"

Transcription

1 : Drawing Details

2 Details cap along edge of silicone transition strip Silicone Transition System (STS) Fillet bead of at top of flashing lapped on to flashing, over STS and onto field layer layers staggered to minimize gap in thermal with backer rod. Set sealant back at joints where movement is expected. Fully apply over sealant joint. Metal flashing to conceal transition strip (flashing not required if cladding covers STS) 758 Silicone Weather Barrier along edge of STS where transition is to membrane by others; otherwise Figure 02. Control Joint Figure 01. Stud Wall to Concrete Wall layers staggered to minimize gap in layers staggered to minimize gap in DefendAir 200 lap fully over STS 4 min. wide Silicone Transition System sealed over gap with 2 min. bond each side. Do not seal gap. 4 min. wide Silicone Transition System sealed over gap with 2 min. bond each side. Do not seal gap. 791 Silicone Continuous along edge of STS Silicone along edge of STS Figure 02a. Control Joint Alternate Figure 02b. Control Joint Alternate 2 1 Silicone Air Barrier System Details

3 Seal all penetrations Silicone Transition System overlap widths to suit condition Coping gap Continuous beads of between STS and air near the gap between stud walls Continuous Weatherproofing cap along edge of STS Continuous exterior insulation over parapet Slope blocking to drain Silicone Transition System Details thermal Silicone cap along edge of STS Figure 03. Silicone Transition System at Parapet Foil-faced self-adhered membrane by others Seal all penetrations Coping gap Continuous insulation over parapet Continuous blocking slope to drain Support as required by foil-faced self-adhered flashing manufacturer lap over SAM Figure 03a. Air Barrier with Self-Adhered Membrane at Parapet BUILD A BETTER BARRIER 2

4 Details layers staggered to minimize gap in thermal layers staggered to minimize gap in 791 Silicone Weatherproofing with backer rod. Set sealant back at joints where movement is expected. Fully apply DefendAir 200 over sealant joint. 4 min. wide Silicone Transition System sealed over gap with 2 min. bond each side. Do not seal gap. along edges of silicone transition strip Figure 04. Change in Wall Substrate Figure 04a. Change in Wall Substrate Alternate layers staggered to minimize gap in thermal 4 min. wide Silicone Transition System sealed over gap with 2 min. bond each side. Do not seal gap. along edges of silicone transition strip applied on wall and over sealant bead in corner Figure 04b. Change in Wall Substrate Alternate 2 Figure 05. Vertical Wall Offset Detail assumes penetration exists prior to installation of air system. Fillet bead of with backer rod support as backing for Weatherproofing with backer rod staggered to minimize gap in applied on wall and over sealant. Extend onto penetration. Figure 06. Wall Penetration 3 Silicone Air Barrier System Details

5 along edge of STS Factor exposed edges on GWB 4 min. wide Silicone Transition System sealed over gap with 2 min. bond each side. Do not seal gap. Lap STS strip 2 in each direction with backer rod Detail assumes penetration exists prior to installation of air system. Detail where differential movement of structure and penetration is expected. to have min. ¼ bite onto substrate and penetration joint as backing for with backer rod staggered to minimize gap in Detail assumes penetration exists prior to installation of air system. applied on wall and over sealant. Extend onto penetration. Figure 06a. Wall Penetration Alternate Figure 06b. Wall Penetration Alternate 2 4 min. wide Silicone Transition System sealed into window mullion lap 2 min. onto sheathing Continuous along edge of STS with backer rod as air seal between window frame and membrane flashing Provide finished GWB edge Continuous bead of 791 Silicone Weatherproofing with backer rod Close flashing as required Exterior insulation two layers staggered to minimize gap in thermal 791 Silicone Weatherproofing with backer rod Apply 778 Silicone Liquid Flashing OR DefendAir 200 with 778 Silicone Liquid Flashing at sill only, extending up jambs 6 and 4 onto face of sheathing Metal closure flashing lapped over flashing coat min. 1 Exterior insulation two layers staggered to minimize gap in thermal Figure 07. Curtain Wall Jamb at Flush Condition STS Flashing Figure 07a. Curtain Wall Jamb at Flush Condition BUILD A BETTER BARRIER 4

6 Silicone cap along edge of STS Silicone Transition System sealed to metal flashing 4 min. wide Silicone Transition System sealed into window mullion and 2 min. onto sheathing Metal drip flashing Curtain wall assembly Continuous cap along edge of STS 791 Silicone lapped min. 1 onto membrane flashing Silicone Transition System sealed to metal flashing Metal drip flashing 791 Silicone with backer rod as air seal between window frame and membrane flashing Apply 778 Silicone Liquid Flashing OR with 778 Silicone Liquid Flashing at sill only, extending up jambs 6 and 4 onto face of sheathing Figure 08. Curtain Wall Head at Flush Condition STS Flashing Figure 08a. Curtain Wall Head at Flush Condition Structural support by others Curtain wall assembly with backer rod Closure flashing shim to provide drainage to exterior 4 Silicone Transition System sealed into window mullion min. 2 lap onto sheathing cap along edge of STS with backer rod as air seal between window frame and membrane flashing with backer rod Closure flashing 778 Silicone Liquid Flashing later applied on sill, 6 up jambs and 4 down face of wall lapped 1 min. over flashing membrane Figure 09. Curtain Wall at Flush Condition STS Flashing Figure 09a. Curtain Wall at Flush Condition 5 Silicone Air Barrier System Details

7 Storefront assembly Figure 10. Storefront Window Head lapped min. 1 over flashing membrane cap along edge of STS Silicone Transition System sealed to metal flashing Metal drip flashing with backer rod Apply 778 Silicone Liquid Flashing OR with 778 Silicone Liquid Flashing at sill only, extending up jambs 6 and 4 onto face of sheathing 791 Silicone with backer rod as air seal between window frame and membrane flashing Continuous interior galvanized metal angle (min. 1 x1 x1/8 ) to support membrane 791 Silicone as air seal between window frame and 778 Silicone Liquid Flashing membrane with backer rod Closure flashing shim to provide drainage to exterior 778 Silicone Liquid Flashing applied on sill, up back and angle and 4 down face of wall sheathing. Extend flashing 6 up jambs. lapped 1 min. over flashing membrane Figure 11a. Storefront Window Sill 778 Silicone Liquid Flashing with backer rod as air seal between window frame and flashing with backer rod Exterior insulation two layers staggered to minimize gap in 4 min. Silicone Transition System sealed onto window mullion with lap STS 2 min onto sheathing cap along edge of STS Exterior insulation two layers staggered to minimize gap in Apply 778 Silicone Liquid Flashing OR Closure flashing as required lapped over flashing coat min. 1 with backer rod Closure flashing as required Figure 12. Storefront Window Jamb Figure 13. Curtain Wall Jamb at Outboard Condition STS Flashing BUILD A BETTER BARRIER 6

8 Continuous cap along edge of STS (typ.) Silicone Transition System sealed to metal flashing 4 min. Silicone Transition System sealed onto window mullion and 2 min onto sheathing Metal drip flashing Curtain wall assembly Curtain wall assembly with backer rod Closure flashing shim to provide drainage to exterior 4 Silicone Transition System sealed onto window mullion min. 2 lap onto sheathing. Terminate STS at frame shoulder. Silicone cap along edge of STS Figure 14. Curtain Wall Head at Outboard Condition STS Flashing Figure 15. Curtain Wall Sill at Outboard Condition STS Flashing Provide finished GWB edge Apply 778 Silicone Liquid Flashing OR DefendAir 200 with 778 Silicone Liquid Flashing at sill only, extending up jambs 6 and 4 onto face of sheathing with backer rod as air seal between window frame and membrane flashing cap along edge of STS layers staggered to minimize gap in Silicone Transition System sealed to metal flashing 4 Silicone Transition System sealed onto flange and 2 min. onto sheathing Metal drip flashing with backer rod Window assembly Figure 16. Flanged Window Head Metal Panel Continuous bead of 791 Silicone Weatherproofing with backer rod as air seal between window frame and 778 Silicone Liquid Flashing membrane Continuous interior galvanized metal angle (min. 1 x1 x1/8 ) to support membrane Intermittent shims behind window flange Window assembly 791 Silicone Weatherproofing with backer rod Closer flashing shim to provide drainage to exterior 778 Silicone Liquid Flashing applied on sill, up back angle and 4 down face of wall sheathing. Extend flashing 6 up jambs. layers staggered to minimize gap in thermal DefendAir 200 lapped 1 min. over flashing membrane Figure 17a. Storefront Window Sill 778 Silicone Liquid Flashing 7 Silicone Air Barrier System Details

9 with backer rod as air seal between window frame and membrane flashing Nail flange set in with backer rod Apply 778 Silicone Liquid Flashing OR with 778 Silicone Liquid Flashing at sill only, extending up jambs 6 and 4 onto face of sheathing Provide finished GWB edge Closure flashing as required lapped over flashing coat min. 1 Exterior insulation two layers staggered to minimize gap in thermal 4 min. wide Silicone Transition System sealed over gap with 2 min. bond each side. Do not seal gap. Silicone cap along edge of STS continuous along face of sheathing Silicone Transition System lapped over and sealed to metal flashing Through wall flashing Silicone cap along edge of STS Figure 18. Flanged Window Jamb Metal Panel Figure 20. Deflection Joint Where Wall Passes in Front of Slab Silicone cap along edge of STS continuous along face of sheathing Silicone Transition System lapped over and sealed to metal flashing Through wall flashing Cap bead of 791 Silicone fully cover with Cap bead of 791 Silicone fully cover with Silicone Transition System lapped over and sealed to metal flashing Cap bead of 791 Silicone fully cover with 4 min. wide Silicone Transition System sealed over gap with 2 min. bond each side. Do not seal gap. Silicone cap along edge of STS Through wall flashing apply to sheathing and exposed slab edge Figure 20a. Deflection Joint Where Wall Passes in Front of Slab Alternate Figure 21. Deflection Joint Where Slab Interrupts Wall (Through Wall Flashing) BUILD A BETTER BARRIER 8

10 Silicone cap along edge of STS (typ.) thermal Silicone Transition System sealed to metal flashing 791 Silicone Continuous 791 Silicone Weatherproofing as air seal between frame and flashing membrane Continuous interior galvanized metal angle (min. 1 x1 x1/8 ) to support membrane Louver assembly 778 Silicone Liquid Flashing applied on sill, up back angle and 4 down face of wall sheathing. Extend flashing 6 up jambs. with backer rod Metal flashing Metal drip flashing Weatherproofing with backer rod Louver assembly Apply 778 Silicone Liquid Flashing OR with 778 Silicone Liquid Flashing at sill only, extending up jambs 6 and 4 onto face of sheathing 791 Silicone with backer rod as air seal between window frame and membrane flashing Provide finished GWB edge lapped 1 min. over flashing membrane layers staggered to minimize gap in thermal Figure 25. Louver Head Figure 26. Louver Sill Metal flashing 791 Silicone with backer rod staggered to minimize gap in lapped 1 min. over flashing membrane Louver assembly Apply 778 Silicone Liquid Flashing OR with 778 Silicone Liquid Flashing at sill only, extending up jambs 6 and 4 onto face of sheathing Continuous as air seal between frame and weatherproof flashing Figure 27. Louver Jamb 9 Silicone Air Barrier System Details

11 Silicone cap along edge of STS (typ.) 791 Silicone lapped 1 min. over flashing membrane Silicone Transition System sealed to metal flashing 791 Silicone Metal drip flashing Detail assumes door is installed after the wall and air system. staggered to minimize gap in Continuous cap along edge of STS (typ.) 791 Silicone lapped 1 min. over flashing membrane Silicone Transition System sealed to metal flashing 791 Silicone Metal drip flashing Weatherproofing with backer rod Door and frame assembly with backer rod as air seal between frame and membrane flashing Apply 778 Silicone Liquid Flashing OR with 778 Silicone Liquid Flashing at sill only, extending up jambs 6 and 4 onto face of sheathing with backer rod Steel door frame Apply 778 Silicone Liquid Flashing OR with 778 Silicone Liquid Flashing at sill only, extending up jambs 6 and 4 onto face of sheathing with backer rod as air seal between frame and membrane flashing Figure 28. Door Head Figure 29. Hollow Metal Door Head DefendAir 200 lapped 1 min. over flashing membrane layers staggered to minimize gap in thermal as air seal between frame and weatherproof flashing Door frame 791 Silicone as air seal between frame and weatherproof flashing Steel door frame Apply 778 Silicone Liquid Flashing OR with 778 Silicone Liquid Flashing at sill only, extending up jambs 6 and 4 onto face of sheathing Provide finished GWB edge 791 Silicone Weatherproofing 791 with backer rod Silicone Weatherproofing with backer rod lapped 1 min. over flashing Apply 778 Silicone Liquid Flashing OR DefendAir 200 with 778 Silicone Liquid Flashing at sill only, extending up jambs 6 and 4 onto face of sheathing Detail assumes door is installed after the wall and air system. membrane Figure 30. Door Jamb Figure 31. Hollow Metal Door Jamb BUILD A BETTER BARRIER 10

12 Existing building Silicone Transition System expansion joint sealed to existing building and Continuous bead of 791 Silicone Weatherproofing Metal closure by others Parapet cap by others Set STS expansion joint in continuous 2 bands of 791 Silicone Weatherproofing Silicone Transition System expansion joint sealed to Set STS expansion joint in continuous 2 bands of lapped over parapet Figure 32. Seismic Joint Figure 33. Seismic Joint at Parapet Sheathing Continuous cap bead of fully cover with layers staggered to minimize gap in Exterior insulation at slab edge and around support brackets 4 min. wide Silicone Transition System sealed over gap with 2 min. bond each side. Do not seal gap. Continuous cap along edges of silicone transition strip Sheathing DefendAir 200 Sheathing Exterior finish cladding per project layers staggered to minimize gap in thermal fillet bead in corner to support application of sealant to have min. ¼ bite onto substrates Soffit panel per project layers staggered to minimize gap in thermal Exterior finish cladding per project Figure 34. Warm Soffit Non-Vented 11 Silicone Air Barrier System Details

13 Sheathing Continuous cap bead of fully cover with See Detail 47b for application of DefendAir 200 at concrete embedded assemblies Exterior insulation at slab edge and around support brackets Silicone fillet bead in corner to support application of sealant to have min. ¼ bite onto substrates Exterior finish cladding per project Sheathing Suspended vented soffit Exterior finish cladding per project Figure 34a. Cold Soffit staggered to minimize gap in lapped over cap seal 758 Silicone Weather Barrier and min. 2 over MTL flashing Do not allow and roofing membranes to come into contact with one another Seal top of flashing with continuous bead of 758 Silicone Weather Barrier (cap seal) Extend roofing base sheet 8 up wall Metal apron flashing Roofing/waterproofing/air /vapor by others Figure 35. Base of Wall at Sloped Roof BUILD A BETTER BARRIER 12

14 staggered to minimize gap in Pre-strip Do not apply SBS roofing membranes over Seal top of flashing with continuous bead of 758 Silicone Weather Barrier lapped over cap seal 758 Silicone Weather Barrier and min. 2 over MTL flashing lapped over cap 758 Silicone Weather Barrier as cap seal over top edge of roofing membrane over MTL flashing Extend roofing base sheet 2 above termination bar Metal counterflashing Roofing base ply flash Roofing cap ply flash Cant strip as required by manufacturer Figure 36. Base of Wall at 2-Ply Roofing Termination Exterior insulation Continuous fillet bead in corner to support application of sealant to have min. ¼ bite onto substrates lapped onto box, top and sides, and onto field layer Electrical box Weatherproofing at wire penetration Weather seal continuous bead of with backer rod all around box at siding staggered to minimize gap in Silicone along edge of STS lapped onto box top and sides, over STS and onto field layer Foil-faced self-adhering membrane (FSAM) target flashing Electrical box or fixture at wire penetration 791 Silicone with backer rod all around box at siding Figure 37. Electrical Box/Fixture With Figure 38. Electrical Box/Fixture/FSAM 13 Silicone Air Barrier System Details

15 Detail assumes is installed before the duct shroud. Silicone along edge of STS Silicone Transition System strip at top and sides of box lapped onto box top and sides, over STS and onto field layer STS edge embedded in continuous bead of Electrical box or fixture lapped min. 1 onto field layer and 2 over duct shroud flashing Seal all sides of flashing with continuous bead of 791 Silicone Duct shroud at wire penetration 791 Silicone with backer rod all around box at siding staggered to minimize gap in with backer rod all around box at siding Figure 38a. Electrical Box/Fixture STS Figure 39. Ducting Penetration Sheathing staggered to minimize gap in Lap over cap seal of 758 Silicone Weather Barrier between and urethane deck coating Note: Most deck coatings will not adhere to. Horizontal waterproofing by others Cant strip as required by manufacturer with backer rod Fillet bead of as backing for Figure 41. Walls at Floor Slab BUILD A BETTER BARRIER 14

16 Spray foam insulation Roofing/waterproofing/air /vapor by others Metal flashing Channel and perforated metal screen Lap onto metal flashing Weatherproofing with backer rod Figure 45. Vented Eaves Detail assumes was installed prior to knife plate. staggered to minimize gap in Metal through-wall flashing beyond Continuous fillet bead around all sides of knife plate assembly to support application of (Alternate sealant: 778 Silicone Liquid Flashing) Weather seal continuous bead of with backer rod all around plate at siding Knife plate Cap all fasteners with before application of lapped onto plate 2 all sides, and min. 1 onto field layer of Set plate in a full bed of and fill all pre-drilled holes 4 min. wide Silicone Transition System sealed over gap with 2 min. bond each side. Do not seal gap. Figure 47. Horizontal Projections, Knife Plate, After 15 Silicone Air Barrier System Details

17 Detail assumes was installed after knife plate. staggered to minimize gap in Metal through-wall flashing beyond Continuous fillet bead around all sides of knife plate assembly to support application of (Alternate sealant: 778 Silicone Liquid Flashing) Weather seal continuous bead of with backer rod all around plate at siding Knife plate Cap all fasteners with before application of coat lapped onto plate 2 all sides, and min. 1 onto field layer of 4 min. wide Silicone Transition System sealed over gap with 2 min. bond each side. Do not seal gap. Continuous cap along edge of STS Figure 47a. Horizontal Projections, Knife Plate, Before staggered to minimize gap in Continuous cap bead of at change of substrate fully cover with Continuous fillet bead around all sides of knife plate assembly to support application of (Alternate sealant: 778 Silicone Liquid Flashing) lapped onto plate 2 all sides, and min. 1 onto field layer of field layer, beyond Weather seal continuous bead of with backer rod all around plate at siding 4 min. wide Silicone Transition System sealed over gap with 2 min. bond each side. Do not seal gap. Continuous cap along edge of STS Figure 47b. Horizontal Projections, Concrete Embed Assembly BUILD A BETTER BARRIER 16

18 to extend 1 min. beyond flange of ducting Knife plate Fill any pre-drilled holes with Apply a full bed of 791 Silicone before knife plate field layer or pre-strip Continuous fillet bead of Cover all fasteners with 791 Silicone before applying collar Continuous fillet bead of all sides of collar cut-out lapped min. 2 over field layer or pre-strip Figure 50. Target Flashing at Knife Plate Isometric Knife plate Continuous fillet bead of all sides Continuous fillet bead of 791 Silicone all sides of cut Cover all fasteners with 791 Silicone before applying lapped over knife plate Figure 50a. Lapped at Knife Plate Isometric 17 Silicone Air Barrier System Details

19 Weatherproofing to extend 1 min. beyond flange of dusting Continuous fillet bead of 791 Silicone all sides Shroud flange Vent shroud Duct opening Apply a full bed of 791 Silicone before shroud field layer or pre-strip Cover all fasteners with 791 Silicone before applying DefendAir 200 strips Apply 6 strips of DefendAir 200 over flange Figure 51. Vent Shroud Flashing Isometric Detail is conceptual and describes design intent. It does not purport to show all conditions. Continuous fillet bead around pipe or conduit sealant to have min. ¼ bite onto substrates Figure 52. Minor Penetration Flashing Isometric BUILD A BETTER BARRIER 18

20 Note: Refer to window head, sill and jamb details. Sequence drawings indicate conceptual installation of flashing only and do not purport to illustrate actual conditions for the interior window wraps (head/jambs/sills). Where metal back angle is to be used, install prior to application of brand weatherproofing products 3 Trowel apply 778 Silicone Liquid Flashing over sill and up back angle per manufacturer s instructions. (Where back angle is not used, apply fully into opening) Apply sealant up jambs 6 and extend 3 onto face of sheathing Figure 105. Window Opening Isometric Sequencing 778 Silicone Liquid Flashing 3 3 Flash head and remainder of jambs with or 778 Silicone Liquid Flashing. Apply per manufacturer s instructions. Extend 3 on to face of sheathing. Overlap 778 Silicone Liquid Flashing with, min. 1 Figure 106. Window Opening Isometric Sequencing 778 Silicone Liquid Flashing 19 Silicone Air Barrier System Details

21 Overlap onto window flashing, min. 1 Field coat Figure 107. Window Opening Isometric Sequencing 778 Silicone Liquid Flashing BUILD A BETTER BARRIER 20

22 Contact us Learn more about the Silicone Air Barrier System and our full range of High Performance Building Solutions, including service and support, at BuildaBetterBarrier.com. Dow Corning has sales offices, manufacturing sites, and science and technology laboratories around the globe. Find local contact information at dowcorning.com/contactus. BuildaBetterBarrier.com Images: AV22605, AV22641, AV22606, AV22645, AV22647, AV22611, AV22639, AV22646, AV22648, AV22500, AV22640, AV20411, AV20715, AV22644, AV20400, AV20401, AV20402, AV20405, AV20403, AV20404, AV20409, AV20406, AV20407, AV20410, AV20408, AV22643, AV20408, AV22648, AV22649 HANDLING PRECAUTIONS PRODUCT SAFETY INFORMATION REQUIRED FOR SAFE USE IS NOT INCLUDED IN THIS DOCUMENT. BEFORE HANDLING, READ PRODUCT AND MATERIAL SAFETY DATA SHEETS AND CONTAINER LABELS FOR SAFE USE, PHYSICAL AND HEALTH HAZARD INFORMATION. THE MATERIAL SAFETY DATA SHEET IS AVAILABLE ON THE DOW CORNING WEBSITE AT DOWCORNING.COM, OR FROM YOUR DOW CORNING SALES APPLICATION ENGINEER, OR DISTRIBUTOR, OR BY CALLING DOW CORNING CUSTOMER SERVICE. LIMITED WARRANTY INFORMATION PLEASE READ CAREFULLY The information contained herein is offered in good faith and is believed to be accurate. However, because conditions and methods of use of our products are beyond our control, this information should not be used in substitution for customer s tests to ensure that our products are safe, effective and fully satisfactory for the intended end use. Suggestions of use shall not be taken as inducements to infringe any patent. Dow Corning s sole warranty is that our products will meet the sales specifications in effect at the time of shipment. Your exclusive remedy for breach of such warranty is limited to refund of purchase price or replacement of any product shown to be other than as warranted. TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW, DOW CORNING SPECIFICALLY DISCLAIMS ANY OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. DOW CORNING DISCLAIMS LIABILITY FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. Dow Corning is a registered trademark of Dow Corning Corporation. We help you invent the future is a trademark of Dow Corning Corporation. Build a Better Barrier is a trademark of Dow Corning Corporation. DensGlass is a registered trademark of Georgia-Pacific Gypsum LLC. THERMAX is a trademark of The Dow Chemical Company. SECUROCK is a registered trademark of USG Dow Corning Corporation. All rights reserved. Printed in USA BBI Form No A-01

RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE. Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS

RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE. Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing

More information

Clad Direct Glaze Window Installation Instructions

Clad Direct Glaze Window Installation Instructions Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully

More information

XYZ Corporation. Project Waterproofing Handbook. 23 June 2008. Working Set Rev. 0. Project Address: 8888 Main Street York, PA 88888

XYZ Corporation. Project Waterproofing Handbook. 23 June 2008. Working Set Rev. 0. Project Address: 8888 Main Street York, PA 88888 Arch itectu ral Te sting Inc. XYZ Corporation 23 June 2008 Project Waterproofing Handbook Working Set Rev. 0 Project Address: 8888 Main Street York, PA 88888 Prepared By: Architectural Testing 4 Rancho

More information

INSTALLATION OF A BAY WINDOW

INSTALLATION OF A BAY WINDOW INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

The Ultimate in Weathersealing Versatility. Dow Corning 123 Silicone Seal

The Ultimate in Weathersealing Versatility. Dow Corning 123 Silicone Seal The Ultimate in Weathersealing Versatility Dow Corning 123 Silicone Seal Effective and attractive EIFS restoration When urethane sealants fail on EIFS-clad buildings, leaks and interior damage typically

More information

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1 Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.

More information

DuPont Tyvek Fluid Applied Flashing Commercial Installation Guidelines

DuPont Tyvek Fluid Applied Flashing Commercial Installation Guidelines DuPont Tyvek Fluid pplied W DuPont Tyvek Fluid pplied Flashing and Joint Compound DuPont Tyvek Fluid pplied Flashing Commercial Installation Guidelines METHODS FOR SUPERIOR PROTECTION GINST IR ND WTER

More information

Sun Windows General Information Sun New Construction Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten

More information

GreenGuard Housewrap Installation Guide

GreenGuard Housewrap Installation Guide 000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions

More information

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read

More information

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.

More information

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................

More information

Tundra Series Windows January 2016

Tundra Series Windows January 2016 Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing

More information

Installation Guide for Andersen Architectural Clad Outswing Commercial Doors

Installation Guide for Andersen Architectural Clad Outswing Commercial Doors Installation Guide for Andersen Architectural Clad Outswing Commercial Doors Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance

More information

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description

More information

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction

More information

Superform Products Ltd.

Superform Products Ltd. TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000

More information

300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO

300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO INSTALL PEEL & STICK (P&S) GUSSETS WITH PRIMER AS PER MANUFACTURERS INSTRUCTIONS 2mm MIN GAP IN SHEATHING STEP 1 PLACE 100mm X 100mm PIECE OF P&S IN CORNER SO THAT IT IS 38mm INTO THE OPENING EACH WAY

More information

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS AC TOPSEAL SELF-ADHERED, GRANULAR SURFACED, SINGLE PLY, LOW SLOPE ROLLED ROOFING 3 X 33.3 = 100 SQ. FT. 10 YEAR MATERIAL LIMITED WARRANTY For Use on Porches / Sheds / Utility Buildings / Accessory Buildings

More information

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements

More information

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS Introduction This inspection guide is organized to follow the EIF System's Installation Guide.

More information

application instructions

application instructions application instructions architectural collection primed bold profile 120 series lap siding (d5, t4, d8, t5, q4) General At the time of manufacture, siding meets or exceeds the performance standards set

More information

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit. Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

LINE OF EXISTING ADJACENT STRUCTURE 6" MIN. PROTECTION COURSE (NOT REQUIRED WHERE THERE IS NO ADJACENT BLDG. MOISTURE RESISTIVE MEMBRANE AT EXIST. AND NEW BLDG. AS OCCURS WATER STOP SLAB-ON-GRADE TERMINATION

More information

application instructions

application instructions application instructions ARCHITECTURAL COLLECTION CEDAR SHAKE 76 SERIES LAP SIDING General At the time of manufacture, siding meets or exceeds the performance standards set forth in Composite Panel Association

More information

AC-3200 ALUMINUM PLATE SYSTEM (DRY JOINT)

AC-3200 ALUMINUM PLATE SYSTEM (DRY JOINT) ALUMINUM PLATE SYSTEM (DRY JOINT) C D E G P J L A H M B Q F A B C D E F G H J K L M N P Q R HORIZONTAL JOINT DETAIL VERTICAL JOINT DETAIL COPING DETAIL (1) COPING DETAIL (2) COPING DETAIL (3) OUTSIDE CORNER

More information

Ver. 2. Guide to. Inspecting Residential Brick Veneer

Ver. 2. Guide to. Inspecting Residential Brick Veneer Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan

More information

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035 Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

LP SmartSide Trim & Fascia

LP SmartSide Trim & Fascia Application Instructions Strand & Fiber Substrate 190, 440, 540 & 2000 Series C A B G F E D A - Corners (Page 6) E - Board and Batten (Page 10) B - Windows, Doors, Openings (Page 7) F - Mounting Blocks

More information

INSTALLATION INSTRUCTIONS for Aluminum Windows with Nail Fin (JII004) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

INSTALLATION INSTRUCTIONS for Aluminum Windows with Nail Fin (JII004) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS for Aluminum Windows with Nail Fin (JII004) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Aluminum windows with an integral nail fin. Not

More information

SECTION STANDING SEAM METAL ROOFING

SECTION STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 41 13 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Use for roofing sloped 1 in 4 (3 in/ft) or greater. 3. Delete between // // if not applicable

More information

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the

More information

INSTALLATION INSTRUCTIONS for Vinyl Patio Doors with Integral Nailing Fin (JII006)

INSTALLATION INSTRUCTIONS for Vinyl Patio Doors with Integral Nailing Fin (JII006) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl Patio Doors with nailing fin. Any local building code requirements supersede the recommended

More information

Mark Cramer Inspection Services, Inc.

Mark Cramer Inspection Services, Inc. Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction

More information

AAMA 2400-10. Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure

AAMA 2400-10. Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure A M E R I C A N A R C H I T E C T U R A L AAMA 2400-10 Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure M A N U F A C T U

More information

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the

More information

Installation Guide for Andersen Architectural Wood Inswing Entry Doors

Installation Guide for Andersen Architectural Wood Inswing Entry Doors Installation Guide for Andersen Architectural Wood Inswing Entry Doors Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are

More information

LISTING INFORMATION OF Alucoil - larson by Alucoil FR 4 mm and 6 mm ACM Panels SPEC ID: 29074. Alucoil North America LLC 1976 Joe Rogers Jr Blvd

LISTING INFORMATION OF Alucoil - larson by Alucoil FR 4 mm and 6 mm ACM Panels SPEC ID: 29074. Alucoil North America LLC 1976 Joe Rogers Jr Blvd LISTING INFORMATION OF Alucoil - larson by Alucoil FR 4 mm and 6 mm ACM Panels SPEC ID: 29074 Alucoil North America LLC 1976 Joe Rogers Jr Blvd Manning, SC 29102 This report is for the exclusive use of

More information

application instructions

application instructions application instructions ARCHITECTURAL COLLECTION PRIMED BOLD PROFILE 120 SERIES LAP SIDING (D5, T4, D8, T5, Q4) General At the time of manufacture, siding meets or exceeds the performance standards set

More information

Fire Barrier Duct Wrap 15A

Fire Barrier Duct Wrap 15A 3 Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions Compliance 1998 Edition Complies with International Mechanical Code Complies

More information

Residential Roofing Guide

Residential Roofing Guide Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...

More information

B. Flexible sheet membranes for eave protection, underlayment, and valley protection. C. Associated metal flashings and accessories. 1.

B. Flexible sheet membranes for eave protection, underlayment, and valley protection. C. Associated metal flashings and accessories. 1. SECTION 07 3113 PART1 GENERAL 1.01 SECTION INCLUDES A. Asphalt shingle roofing. B. Flexible sheet membranes for eave protection, underlayment, and valley protection. C. Associated metal flashings and accessories.

More information

application instructions

application instructions application instructions FOUNDATIONS 76 & 120 SERIES PRIMED PANEL SIDING ARCHITECTURAL COLLECTION REVERSE BOARD & BATTEN AND STUCCO PANEL SIDING General At the time of manufacture, siding meets or exceeds

More information

INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg

INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg Thank you for selecting JeLd-weN products. Attached are JeLd-weN s recommended installation instructions for pocket (replacement) double-hung, casement, awning, picture or transom windows, designed to

More information

Renovating Your Basement

Renovating Your Basement building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

application instructions

application instructions application instructions PRECISION SERIES 38 AND 76 SERIES PRIMED LAP SIDING General At the time of manufacture, siding meets or exceeds the performance standards set forth in ICC-ES-AC321 and has achieved

More information

DuPont Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines Installation Instructions for Windows and Doors EFORE Water-Resistive arrier (WR) is Installed DuPont Flashing Systems Installation Guidelines INSTLLTION INSTRUTIONS FOR WINDOWS ND DOORS EFORE WTER-RESISTIVE

More information

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings VERSION 1/16 FOR SINGLE FAMILY HOMES AND LOW RISE MULTI-FAMILY BUILDINGS LESS THAN 4 STORIES Tyvek

More information

Please visit our website for additional information and contacts.

Please visit our website for additional information and contacts. 1 This manual contains basic information, drawings and guides for installing the Polysand Slate Tile Roofing System on a basic type structure. This manual is a summary of good roofing practices and some

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nail fin. Not all window types may be installed into every wall

More information

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING

More information

Tools required by installer: Materials required by installer:

Tools required by installer: Materials required by installer: Installation Guidelines For Quaker Window Products Vinyl replacement product line (Single Hung, Double Hung, Sliding Window, Fixed Window, Casement, Awning, and Hopper) Installer: Read these instructions

More information

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed

More information

PANELIZED HOME INSTALLATION GUIDELINE

PANELIZED HOME INSTALLATION GUIDELINE PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.

More information

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein

More information

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

Window Sill Details for Effective Drainage of Water

Window Sill Details for Effective Drainage of Water Construction Technology Update No. 76 Window Sill Details for Effective Drainage of Water By M.A. Lacasse and M.M. Armstrong Satisfactory window performance demands a good product and proper installation.

More information

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit. Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden

More information

DIVISION OF CAPITAL ASSET MANAGEMENT AND MAINTENANCE THE COMMONWEALTH OF MASSACHUSETTS STANDARD SPECIFICATIONS MGL CHAPTER 149A CM-AT-RISK PROJECTS

DIVISION OF CAPITAL ASSET MANAGEMENT AND MAINTENANCE THE COMMONWEALTH OF MASSACHUSETTS STANDARD SPECIFICATIONS MGL CHAPTER 149A CM-AT-RISK PROJECTS DIVISION OF CAPITAL ASSET MANAGEMENT AND MAINTENANCE THE COMMONWEALTH OF MASSACHUSETTS STANDARD SPECIFICATIONS MGL CHAPTER 149A CM-AT-RISK PROJECTS DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

More information

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-

More information

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

Support Joining Guide

Support Joining Guide Guide Guide for Andersen Casement, Awning, and Picture Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential

More information

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs CertainTeed Self-Adhering Roof Systems for Low Slope Residential Roofs Goes down fast. Stays on strong. Flintlastic SA performs in all the right ways. What s more important to you? Speed of installation,

More information

SECTION 07 61 13 STANDING SEAM METAL ROOFING

SECTION 07 61 13 STANDING SEAM METAL ROOFING SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced

More information

Leaky Homes Financial Assistance Package (FAP) Repair plan example

Leaky Homes Financial Assistance Package (FAP) Repair plan example LEAKY HOMES FINANCIAL ASSISTANCE PACKAGE FACT SHEET Repair Plan Example - June 2014 Page 1 Leaky Homes Financial Assistance Package (FAP) Repair plan example Introduction This repair plan example is intended

More information

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar VERSION 1/16 FOR SINGLE FAMILY HOMES AND LOW-RISE MULTI-FAMILY BUILDINGS

More information

SECTION 073113 ASPHALT SHINGLES

SECTION 073113 ASPHALT SHINGLES 1320 / Talent Community Center 073113-1 ASPHALT SHINGLES PART 1 GENERAL 1.01 SECTION INCLUDES A. Asphalt shingle roofing. B. SBS roof membrane. SECTION 073113 ASPHALT SHINGLES C. Flexible sheet membranes

More information

CHAPTER 7: Building Systems ROOFING SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen

More information

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration DS497 SECTION ONE A. Objective The objective of this guide is to provide owners and general contractors/construction

More information

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within

More information

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam

More information

Brick Veneer Construction

Brick Veneer Construction Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power

More information

Finegan Inspection Services, Inc.

Finegan Inspection Services, Inc. Finegan Inspection Services, Inc. Report Prepared For: Phone 513-683-0733 Fa 513-697-0163 Owners Property Address City, State, ZIP Phone FAX Owners Realtor Realty Company Phone FAX OWNER INFORMATION PROPERTY

More information

Although we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal

Although we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal Installing a Low-Slope Exposed EPDM for roof transition Exposed EPDM for resistance to ice damming Sidewall flashing Done with care, a flat roof can provide 0 years or more of leak-free service Gravel

More information

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls

More information

Comment Form on Proposed Gut Rehabilitation Alternatives

Comment Form on Proposed Gut Rehabilitation Alternatives Comment Form on Gut Rehabilitation Alternatives Name: Organization: Email: Instructions Submission: Please submit this form to energystarhomes@energystar.gov by October 10 th, 2012 with the subject line

More information

Vinyl Windows and Doors Manufactured by Pella Corporation

Vinyl Windows and Doors Manufactured by Pella Corporation Vinyl Windows and Doors Manufactured by Pella Corporation Part Number: V785079 Pella Corporation 2007 INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG WINDOWS USING FRAME SCREWS

More information

Avoiding Air Barrier Pitfalls

Avoiding Air Barrier Pitfalls Avoiding Air Barrier Pitfalls Design & Durability November 2013 Air barriers, when correctly installed, help buildings achieve high levels of energy efficiency by decreasing heat loss. For example, great

More information

WINDOW PANNING AND TRIMS

WINDOW PANNING AND TRIMS OCTOBER, 2010 PANNING AND TRIMS GENERAL INFORMATION 1 EXTERIOR PANNING Panning is primarily used to cover the perimeters of existing building openings prior to the installation of replacement windows.

More information

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

NRG 75 CRF NRG GREENBOARD WALL SYSTEM NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark

More information

The WANZ Guide to Window Installation

The WANZ Guide to Window Installation The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check

More information

Chapter 9: INSTALLING ROOFING

Chapter 9: INSTALLING ROOFING 9.1 LEAK BARRIER (ICE AND WATER SHIELD) 9.2 SHINGLE UNDERLAYMENT 9.3 INSTALLING GUTTER APRON AND GABLE D-EDGE 9.4 INSTALLING SHINGLES 9.5 RIDGE VENT AND CAP Tools needed by each volunteer: Hammer (16 oz.

More information

September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections

More information

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for vinyl windows without a nailing fin (including finless, flush fin and flange). Read these instructions

More information

Florida Building Code, 5 th Edition SHINGLE ROOFING

Florida Building Code, 5 th Edition SHINGLE ROOFING Florida Building Code, 5 th Edition SHINGLE ROOFING Date Issued/Updated: July 6, 2015 This bulletin addresses the current Building Code roofing and re roofing requirements for shingle roofing systems.

More information

Directions For Applying Malarkey Laminate Shingles

Directions For Applying Malarkey Laminate Shingles S Laminate Shingle Instructions 1 Directions For Applying Malarkey Laminate Shingles GENERAL INSTRUCTIONS Install Malarkey laminate shingles according to building code and local amendments. To qualify

More information

WINDOW INSTALLATION GUIDE

WINDOW INSTALLATION GUIDE WINDOW INSTALLATION GUIDE is not responsible for or liable for any use or misuse of the information contained in this window installation guide. Window Installation Guide This guide provides basic information

More information

REPLACE ROOFING DENVER CENTRAL LIBRARY PHASE I CITY & COUNTY OF DENVER DENVER, COLORADO

REPLACE ROOFING DENVER CENTRAL LIBRARY PHASE I CITY & COUNTY OF DENVER DENVER, COLORADO PUBLIC LIBRARY PHASE I 4828 W. 6TH Avenue, Unit B-8 Golden, Colorado 8040 Phone: (303) 233-092 VICINITY MAP SHEET INDEX GT /26/2009 SHEET DESCRIPTION G.0 COVER SHEET R.0 COMPOSITE ROOF PLAN R. NEW ROOF

More information

Barewood Octagon and Elongated Windows Installation Instructions

Barewood Octagon and Elongated Windows Installation Instructions Step-by-step instructions to a beautiful window. Measuring and Installation of your new window from Century Specialty Windows couldn't be easier with our step-by-step instructions. Quality, function and

More information

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11

More information

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Brought To You By: MyShedPlans Click Here To Download 12,000 Shed Plans >> 12 x 8 Basic Shed This 8 12-ft. shed features a simple

More information

12.1 Schlüter -KERDI-BOARD

12.1 Schlüter -KERDI-BOARD I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter

More information

TARRANT COUNTY DETAIL STANDARDS

TARRANT COUNTY DETAIL STANDARDS TARRANT COUNTY DETAIL STANDARDS 1. Standard Coping 2. Coping at End Wall 3. Standard Sheet Metal Engagement Details 4. Gravel Guard 5. Gravel Guard Wall Termination 6. Gravel Guard, Gutter, and Downspout

More information