Free Match Series R410A GMV Multi VRF Duct Type Indoor Unit (For North America)

Size: px
Start display at page:

Download "Free Match Series R410A GMV Multi VRF Duct Type Indoor Unit (For North America)"

Transcription

1 Change for life Free Match Series R410A GMV Multi VRF Duct Type Indoor Unit (For North America) Owner's Manual Commercial Air Conditioners Thank you for choosing Commercial Air Conditioners, please read this owner s manual carefully before operation and retain it for future reference.

2 User Notice The total capacity of the indoor units which runs at the same time can not exceed 150% of that of the outdoor units; otherwise, the cooling (heating) effect of each indoor unit would be poor. Switch the main power on 8 hours before start the unit, helpful for a successful startup. It is a normal phenomenon that the indoor unit fan will still run for 20~70 seconds after the indoor unit receives the stop signal so as to make full use of after-heat for the next operation. When the running modes of the indoor and outdoor units conflict, it will be indicated on the display of the wired controller in five seconds and then the indoor unit will stop. In this case, they can back to the normal condition by harmonizing their running modes: The HEAT mode conflicts with each of the COOL mode, DRY mode and FAN mode, while the COOL mode, DRY mode and FAN mode are compatible between each other. If the supply power fails when the unit is running, then the indoor unit will send the start signal to the outdoor unit three minutes later after power recovery. During installation, the communication cable and the power cord must not be twisted together but instead separated with an interval of at least 2cm, otherwise the unit is likely to run abnormally. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. This product must not be disposed together with the domestic waste. This product has to be disposed at an authorized place for recycling of electrical and electronic appliances. Thank you for selecting Gree air conditioner. Before use, please read this manual carefully and keep it properly for furthur reference.

3 Contents 1 Safety Precautions Installation Location and Matters Needing Attention How to select the Installation Location for the indoor unit Electric Wiring Earthing Requirements Accessories for Installation Installation Instructions Outline Dimension Drawings of the Indoor Unit Dimension Requirements on the Installation Space of the Indoor Unit Installation of the Indoor Unit Horizontality Check of the Indoor Unit Installation of the Air Supply Duct Drawings of the Air Supply Outlet and Return Air Inlet Installation of the Return Air Duct Installation of the Condensate Pipe Design of the Drain Pipe Installation of the Drain Pipe Precautions for the Lift Pipe Test for the Drainage System Piping Insulation for the Refrigerant Pipe Wiring between the Wire and the Wiring Terminal Wiring of the Power Cord (single-phase) Wiring of the Signal Line of the Wired Controller Electric Installation Rated Working Conditions Error Analysis Maintenance... 19

4 1 Safety Precautions Please read this manual carefully before using and operating correctly as instructed in this manual. Please take special attention to the meaning of these two marks: Warning! It indicates improper operation which will lead to human casualty or severe injury. Note! It indicates improper operation which will lead to injury or property damage. Warning: The installation should be committed to the appointed service center; otherwise it will cause water leakage, electric shock or fire etc.. Please install the unit at a place where is strong enough to withstand the weight of the unit; otherwise, the unit would fall down and cause injury or death. The drain pipe should be installed as instructed in the manual to guarantee the proper drainage; meanwhile it should be insulated to prevent condensing; otherwise the improper installation would cause water leakage and then wet the household wares in the room. Do not use or place any inflammable, combustible or any noxious substance next to the unit. Under the occurrence of an error (like burning smell etc.), please cut off the main power supply of the unit. Keep good ventilation in the room to avoid oxygen deficit. Never insert your finger or any other object into the air outlet/inlet grille. Please take notice of the supporting frame of the unit to see if it is damaged over the long time period of use. Never refit the unit and contact the sales agent or the professional installation personnel for the repair or relocation of the unit. An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring. Caution! Before installation, please check if the power supply corresponds with the requirement specified on the nameplate and also check its security. Before using the unit, please check if the piping and wiring are correct to avoid water leakage, refrigerant leakage, electric shock, or fire etc. The main power supply must be earthed to avoid the hazard of electric shock and never connect this earth wire to the gas pipe, running water pipe, lightening rod or phone cable s earth lead. Turn off the unit after it runs at least five minutes; otherwise its service life will be shortened. Do not allow children operate this unit. Do not operate this unit with wet hands. Cut off the main power supply prior to the cleaning of the unit or the replacement of the air filter. When the unit is not to be used for a long time, please cut off the main power supply of the unit. Do not expose the unit to the moist or corrosive circumstances. After the electric installation, please take an electric leakage test. 1

5 2 Installation Location and Matters Needing Attention The installation of the unit must comply with the national and local safety regulations. The installation quality directly affects the normal use, so the user should not carry out the installation personally, instead, the installation and debugging should be done by technician according to this manual. Only after that, can the unit be energized. 2.1 How to select the Installation Location for the indoor unit (1). Where there is no direct sunlight. (2). Where the top hanger, ceiling and the building structure are strong enough to withstand the weight of the unit. (3). Where the drain pipe can be easily connected to outside. (4). Where the flow of the air inlet and outlet are not blocked. (5). Where the refrigerant pipe of the indoor unit can be easily led to outside. (6). Where there is no inflammable, explosive substances or their leakage. (7). Where there is no corrosive gas, heavy dust, salt mist, smog or moisture. CAUTION! The unit which is installed in the following places is likely to run abnormally. If unavoidable, please contact the technician at the GREE appointed service center: 1 Where is full of oil; 2 Alkaline soil off the sea; 3 Where there is sulfur gas(like sulfur hot spring); 4 Where there are devices with high frequency (like wireless devices, electric welding devices, or medical equipments); 5 Special circumstances. 2.2 Electric Wiring (1). The installation must be done in accordance with the national wiring regulations. (2). Only the power cord with the rated voltage and exclusive circuit for the air conditioning can be used. (3). Do not pull the power cord by force. (4). The electric installation should be carried out by the technician as instructed by the local laws, regulations and also this manual. (5). The diameter of the power cord should be large enough and once it is damaged it must be replaced by the dedicated one. (6). The earthing should be reliable and the earth wire should be connected to the dedicated device of the building by the technician. Besides, the air switch coupled with the leakage current protection switch must be equipped, which is of enough capacity and of both magnetic and thermal tripping functions in case of the short circuit and overload. 2.3 Earthing Requirements (1). The air conditioner is classified into the Class I appliances, so its earthing must be reliable. (2). The yellow-green line of the air conditioner is the earth line and can not be used for other 2

6 purpose, cut off or fixed by the tapping screw; otherwise it would cause the hazard of electric shock. (3). The reliable earth terminal should be provided and the earth wire can not be connected to any of the following places: 1.Running water pipe; 2.Coal gas pipe; 3.Sewage pipe; 4.Other places where the technician think unreliable. 2.4 Accessories for Installation Refer to the packing list for the accessories of the indoor and outdoor units respectively. 3

7 3 Installation Instructions 3.1 Outline Dimension Drawings of the Indoor Unit Note: the unit in the followings figures is mm, unless otherwise specified. Fig.1 is applicable to GFH(09)EA-D3DNA1A/I,GFH(12)EA-D3DNA1A/I,GFH(18)EA-D3DNA1A/ I, GFH(21)EA-D3DNA1A/I, GFH(24)EA-D3DNA1A/I: G Electric BoxLi quid Pipe Gas Pipe Backward I Return Air H E Drain Pipe A Downward Return Air D F J B C Fig.1 Table 1: Outline Dimensions Item Model A B C D E F G H I J GFH(09)EA-D3DNA1A/I GFH(12)EA-D3DNA1A/I GFH(18)EA-D3DNA1A/I GFH(21)EA-D3DNA1A/I GFH(24)EA-D3DNA1A/I Dimension Requirements on the Installation Space of the Indoor Unit Nut with washer Spring pad >500 Fig. 2 >250 4

8 3.3 Installation of the Indoor Unit (1). Requirements on the Installation Location 1) Ensure the hanger is strong enough to withstand the weight of the unit. 2) The drainage pipe is easy for connection. 3) No obstacle is in the inlet/outlet and the air circulation is in good condition. 4) Ensure the installation space shown in Fig.2 is left for the access to maintenance. 5) It should be far away from where there is heat source, leakage of inflammable, explosive substances, or smog. 6) It is the ceiling type unit (concealed in the ceiling). 7) The power cords and connection lines of the indoor and outdoor units must be at least 1m away from the TV set or radio to avoid the image interference and noise ( even if 1m is kept, the noise may be produced due to the strong electromagnetic wave). (2). Installation of the Indoor Unit Insert the M10 expansion bolt into the hole, and then knock the nail into the bolt. Refer to the Outline Dimension Drawings of the Indoor Unit for the distance between holes and see Fig.3 for the installation of the expansion bolt. Hanger bolt Air conditioning unit Anchor Fig.3 Install the hanger on the indoor unit, as shown in Fig.4. Install the indoor unit on the ceiling, as shown in Fig.5. Fig.4 48mm Fig.5 CAUTION! 1. Prior to the installation, please make a good preparation for all piping (refrigerant pipe, drain pipe) and wiring (wires of the wired controller, wires between the indoor and outdoor unit) of the indoor unit to make the further installation much easier. 5

9 2. If there is an opening in the ceiling, it is better to reinforce it to keep it flat and prevent it vibrating. Consult the user and builder for more details. 3. If the strength of the ceiling is not strong enough, a beam made of angle iron can be used and then fix the unit on it. 4. If the indoor unit is not installed in the air conditioning area, please use sponge around the unit to prevent condensing. The thickness of the sponge depends on the actual installation environment. 3.4 Horizontality Check of the Indoor Unit After the installation of the indoor unit, its horizontality must be checked to make sure the unit keep horizontal fore and aft and keep an inclination of 5 toward the drain pipe right and left, as shown in Fig.6. Horizontality Check Device Fig Installation of the Air Supply Duct (1). Installation of the Rectangular Air Supply Duct Return air Return air Supply air Fig.7 Table 2 No. Name No. Name 1 Hanger 5 Plenum Box 2 Return Air Duct 6 Filter Screen 3 Canvas Duct 7 Main Air Supply Duct 4 Return Air Inlet 8 Air Supply Outlet (2). Installation of the Round Air Supply Duct 6

10 Fig.8 Table No. Name No. Name 1 Return Air Duct 6 Transition Duct 2 Canvas Duct 7 Air Supply Duct 3 Return Air Louver 8 Diffuser 4 Hanger 9 Diffuser Joint 5 Air Supply Outlet (3). Installation Steps of the Round Air Supply Duct 1). Preinstall the outlet of the round duct on the transition duct and then fix it by the tapping screw. 2). Place the transition duct to the air outlet of the unit and fix it with rivet. 3). Connect the outlet to the duct and then tighten them with tape. Other installation details are not covered herein. CAUTION! 1. The maximum length of the duct means the maximum length of the air supply duct plus the maximum length of the return air duct. 2. For the unit with the auxiliary electric heating function, if the round duct is to be adopted, then the straight length of the transition duct can not be less than 200mm. 3. The duct is either rectangular or round and connected with the air inlet/outlet of the indoor unit. Among all air supply outlets, at least one should be kept open. As for the round duct, it needs a transition duct of which the size should match with the air supply outlet of the unit. After the fitting of the transition duct, it is the turn of the round duct, which is better to be kept 10 meters far away from the corresponding diffuser. The standard accessories supplied by GREE is the transition duct 200mm long and round air outlet φ200, however, those of other specifications can be purchased. 3.6 Drawings of the Air Supply Outlet and Return Air Inlet 7

11 21 A D B C Fig.9 Air Supply Outlet Fig.10 Return Air Inlet Table 4 Dimensions of the Air Supply Outlet and Return Air Inlet (unit: mm) Item Air Supply Outlet Return Air Inlet Model A B C D GFH(09)EA-D3DNA1A/I GFH(12)EA-D3DNA1A/I GFH(18)EA-D3DNA1A/I GFH(21)EA-D3DNA1A/I GFH(24)EA-D3DNA1A/I 3.7 Installation of the Return Air Duct (1). The default installation location of the rectangular flange is in the back and the return air cover plate is in the bottom, as shown in Fig.11. Rectangular Flange Backward Return Air Downward Return Air Return Air Cover Plate Fig.11 (2). If the downward return air is desired, just change the place of the rectangular flange and the return air cover plate. (3). Connect one end of the return air duct to the return air outlet of the unit by rivets and the other to the return air louver. For the sake of the convenience to freely adjust the height, a cutting of canvas duct will be helpful, which can be reinforced and folded by 8# iron wire. (4). More noise is likely to be produced in the downward return air mode than the backward return air mode, so it is suggestive to install a muffler and a plenum box to minimize the noise. (5). The installation method can be chosen with considering the conditions of the building and maintenance etc., as shown in Fig.12. 8

12 Wind supply Back wind Install the back wind pipe (a) 2 1 Wind supply Fig.12 Install the back wind pipe(b) Table 5 Parts and Components of the Return Air Duct No. Name No. Name 1 Return Air Louver(with the filter screen) 4 Indoor Unit Back wind 2 Canvas Duct 5 Air Supply Duct 3 Return Air Duct 6 Access Grille 3.8 Installation of the Condensate Pipe (1). The condensate pipe should keep a inclination angle of 5 ~ 10, which can facilitate the drainage of the condensate water. And the joints of the condensate pipe should be insulated by the insulation material to prevent condensing(see Fig.13). Insulating Layer for the Condensate Pipe 1 Pipe Lid Fig.13 Thermal Insulation of the Condensate Pipe (2). There is a condensate outlet on both left and right sides of the unit. Once one is confirmed to be used, the other should be clogged by a rubber plug, bundled by the binding wire and insulated by the insulation material to avoid water leakage. (3). The right outlet is defaulted to be clogged with a plug. CAUTION! No water leakage is allowed on the joint of the condensate pipe. 3.9 Design of the Drain Pipe (1). The drain pipe should always keep an inclination angle(1/50 ~ 1/100) to avoid the water gathering in some certain place. (2). During the connection of the drain pipe and device, do not impose too much force on the pipe on one side of the device and the pipe should be fixed as close as to the device. (3). The drain pipe can be the ordinary hard PVC pipe which can be purchased locally. During the connection, inset the end of the PVC pipe to the drain outlet, then tighten it with the drain hose and binding wire but never connect the drain outlet and the drain hose by adhesive. 9

13 (4). When the drain pipe is used for multiple devices, the public section of the pipe should be 100mm lower than the drain hole of each device and it is better to use the much thicker pipe for such a purpose Installation of the Drain Pipe (1). The diameter of the drain pipe should be larger than or equal to that of the refrigerant pipe (PVC pipe, outer dimater:25mm, wall thickness 1.5mm. (2). The drain pipe should be as short as possible and with at least a 1/100 degree of slope to avoid forming air pockets. (3). If the proper degree of slope of the drain pipe is not allowed, a lift pipe should be installed. (4). A distance 1-1.5m should be kept between the hangers to avoid the drain hose making a turn. 1~1.5m (Right) with a min. degree of slope 1/100 (Wrong) Fig.14 (5). Insert the drain hose into the drain hole and tighten it with clamps. (6). Wrap the clamps with large amount of sponge for thermal insulation. (7). The drain hose inside the room also should be insulated. Clamp (accessory) Sponge (accessory) Clamp (accessory) Sponge (gray) Drain Hose Fig.15 Max. 4mm 10

14 3.11 Precautions for the Lift Pipe The installation height of the lift pipe should be less than 850mm. It is recommended to set an inclination angle 1 ~ 2 for the lift pipe toward the drainage direction. If the lift pipe and the unit form a right angle, the height of the lift pipe must be less than 800mm. 1~1.5m Hanger Bracket Ceiling 1000mm 850mm 150mm Lift Pipe 300mm 1 ~2 Drain Hose (accessory) 1 2Clamp (accessory) Notes: Fig The inclination height of the drain hose should be within 75mm so that the outlet of the drain hose does not suffer the external force. 2. If multiple drain pipes converge, please follow the installation steps below. I - Joint of drain pipe The specification of the joint of the drain pipe should be suitable to the running capacity of the unit Max.1000mm Max.75mm Drain Hose (accessory) Fig Test for the Drainage System (1). After the electric installation, please take a test for the drainage system. (2). During the test, check if the water flow goes through the pipe correctly and observe 11

15 carefully the joint to see if it leaks or not. If this unit is installed in the newly built house, it is suggested to take this test prior to the ceiling decoration Piping (1). Let the flare end of the copper pipe point at the screw and then tighten the screw by hand. (2). After that, tighten the screw by the torque wrench until it clatters (as shown in Fig.18). Pipe Flare Nut Pipe Spanner Fig.18 Table 6 Moments of Torque for Tightening Screws Diameter of Pipe(mm) Moment of Torque (N m) φ φ φ φ (3). The bending degree of the pipe can not be too small; otherwise it will crack. And please use a pipe tube bender to bend the pipe. (4). Wrap the exposed refrigerant pipe and the joints by sponge and then tighten them with the plastic tape. CAUTION! 1. During the connection of the indoor unit and the refrigerant pipe, never pull any joints of the indoor unit by force; otherwise the capillary pipe or other pipe may crack, which then would result in leakage. 2. The refrigerant pipe should be supported by brackets, that is, don t let the unit withstand the weight of it. If the specification of the outdoor unit pipe joint does not conform to that of the indoor unit, then the joint specification of the outlet pipe of the indoor unit takes precedence. A reducing nipple shall be installed at the joint of the outdoor unit so as to make the joint of the outdoor unit compatible with that of the indoor unit Insulation for the Refrigerant Pipe (1). The refrigerant pipe should be insulated by the insulating material and plastic tape in order to prevent condensation and water leakage. (2). The joints of the indoor unit should be wrapped with the insulating material and no gap is 12

16 allowed on the joint of the indoor unit, as shown in Fig.19. No gap Fig.19 CAUTION! After the pipe is protected well enough, never bend it to form a small angle; otherwise it would crack or break. (3). Wrap the pipe with tape. 1). Bundle the refrigerant pipe and electric wire together with tape, and separate them from the drain pipe to prevent the condensate water overflowing. 2). Wrap the pipe from the bottom of the outdoor unit to the top of the pipe where it enters the wall. During the wrapping, the later circle should cover half of the former one. 3). Fix the wrapped pipe on the wall with clamps. CAUTION! 1. Do not wrap the pipe too tightly; otherwise the insulation effect would be weakened. Additionally, make sure the drain hose is separated from the pipe. 2. After that, fill the hole on the wall with sealing material to prevent wind and rain coming into the room Wiring between the Wire and the Wiring Terminal (1). Wiring of the Single-Core Wire 1). Strip the insulating layer at the end of the wire about 25mm off with a wire striper. 2). Loosen the screw off on the wiring board of the air conditioning unit. 3). Shape with the pliers at the end of the wire to a circle matching with the size of the screw. 4). Let the screw go through the circle of the wire and then fix it on the wiring board. (2). Wiring of the Multi-Core Wire 1). Strip the insulating layer at the end of the wire about 100mm off with a wire striper. 2). Loosen the screw off on the wiring board of the air conditioning unit. 3). Fix a wiring terminal matching with the size of the screw to the end of the multi-core wire with the crimpling pliers. 4). Let the screw go through the terminal of the multi-core wire and then fix it on the wiring board. 13

17 A.Single-Cored Wire B.Mulit-Cored Wire Wiring Terminal Insulating layer one. Fig.20 WARNING! 1. If the power cord or the signal line is damaged, they must be replaced with the dedicated 2. Prior to the wiring, please check the voltage marked on the nameplate and then carry out the wiring following the wiring diagram. 3. The dedicated power cord must be used for the air conditioning unit and the electrical leakage protection switch and air switch must be installed in case of the overload condition. 4. The air conditioning unit must be earthed to prevent the hazard caused by the failed insulation. 5. During the wiring, the wiring terminal or the single-core wire must be used; the direct wiring between the multi-core wire and wiring board would cause fire. 6. All wiring should be done strictly in accordance with the wiring diagram; otherwise the improper wiring would cause the air conditioning unit running abnormally or damaged. 7. Do not let the electric wires touch the refrigerant pipe, the compressor, the fan or other moving parts. 8. Do not modify the wiring inside the indoor unit randomly; otherwise the manufacturer won t assume any responsibility for the damage or abnormal running of the unit Wiring of the Power Cord (single-phase) CAUTION! The power supply for each indoor unit must be uniform. 1.Dismantle the cover of the electric box of the indoor unit. 2.Let the power cord go through the rubber ring. 3.Put the 4-core cable through the hole of the chassis and the bottom of the appliance upward, and then connect the power line and the communication line from the outdoor unit to the corresponding terminals N(1), 2, 3, and grounding terminal of the indoor unit. Wiring shall be done properly as per the wiring diagram. (Note: Be sure the wring terminals A/B/C/D and piping joints A/B/C/D of the indoor unit match with that of the outdoor unit respectively). 4.Fix the power cord tightly with the binding wire. GWHD(36)NK3AO 14

18 INDOOR UNIT D INDOOR UNIT C INDOOR UNIT B INDOOR UNIT A POWER XT XT XT2 OUTDOOR UNIT N L GWHD(42)NK3AO Fig.21 INDOOR UNIT E XT6 G INDOOR UNIT D XT5 G INDOOR UNIT C INDOOR UNIT B G XT4 XT3 OUTDOOR UNIT G INDOOR UNIT A XT2 G L POWER N XT1 Fig.22 15

19 3.17 Wiring of the Signal Line of the Wired Controller (1). Open the cover of the electric box of the indoor unit. (2). Let the signal line go through the rubber ring. (3). Insert the signal line to the four-pin socket on the printed circuit board of the indoor unit. (4). Fix the signal line with the binding wire Electric Installation Table 7 Type Indoor Unit Model Power Supply Running Current (A) Indoor Fan Motor Input Power(W) Cooling Heating Recommended Power Cord (Sectional Area Pieces) GFH(09)EA-D3DNA1A/I 208/230V~ 60Hz AWG18 4 Cooling and Heating GFH(12)EA-D3DNA1A/I 208/230V~ 60Hz AWG18 4 GFH(18)EA-D3DNA1A/I 208/230V~ 60Hz AWG18 4 GFH(21)EA-D3DNA1A/I 208/230V~ 60Hz AWG18 4 GFH(24)EA-D3DNA1A/I 208/230V~ 60Hz AWG18 4 Notes: The sectional area listed above is applicable to the power cord with at most a length of 15 meters. For the longer cord, its sectional area should be enlarged to avoid the cord burning out caused by the over-current. 16

20 4 Rated Working Conditions Table 8 Working Temperature Range Indoor side state ( ) Outdoor side state ( ) Dry bulb temp. ( ) Wet bulb temp. ( ) Dry bulb temp. ( ) Wet bulb temp. ( ) Rated. Cooling 80.0(26.7) 67.0(19.4) 95.0(35.0) 75.0(23.9) Max. cooling 80.0(26.7) 67.0(19.4) 115.0(46.1) 75.0(23.9) Min. cooling 67.0(19.4) 57.0(13.9) 67.0(19.4) 57.0(13.9) Rated. Heating 70.0(21.1) 60.0(15.6) 47.0(8.3) 43.0(6.1) Max. heating 80.0(26.7) 75.0(23.9) 65.0(18.3) Low Ambient heating 70.0(21.1) 60.0(15.6) 5.0(-15.0) 3.2(-16.0) 17

21 5 Error Analysis If your conditioning unit runs abnormally, please check the following items before contacting the maintenance serviceman. Table 9 Errors Possible Causes There is no power supply. Failed startup The breaker opens owing to electrical leakage. Voltage is too low. Stop after a short while of The air inlet/outlet of the indoor/outdoor unit is clogged. operation The air filter screen is too dirty or clogged. There are too much heat sources or people in the room. Poor cooling effect The door or window is open. There are obstacles at the air inlet/outlet. The set temperature is too high. The air filter screen is too dirty or clogged. Poor heating effect The door or window is not closed fully. The set temperature is too low. If the remote controller crashes even if the batteries have been replaced, please open the back cover of it and press the button ACL to let it back to the normal condition. Is the remoter controller in the signal receiving range? Or is it Uncontrollable controller blocked by obstacles? For the duct type unit, operate the remote controller pointing at the wired controller. Check if the otherwise change new batteries. of the wired controller is enough; or change them. Note: If the air conditioner still runs abnormally after the above check and handling, please contact the maintenance serviceman at the local appointed service center. 18

22 6 Maintenance CAUTION! Take notice of the following items before cleaning your air conditioning unit. (1). Cut off the main power supply before contacting any wiring device. (2). Only when the unit is turned off and the main power supply is cut off, can the unit be cleaned; otherwise it would cause an electric shock or injury. (3). Do not wash the unit with water; or it may cause an electric shock. (4). During the cleaning, remember to use the stable standing platform Daily Maintenance. 1). How to clean the filter 1.Never dismantle the air filer except for cleaning; otherwise it may cause some error. 2.When the air conditioning unit is used under the environment with heavy dust, the air filter should be cleaned often (generally once every two weeks). 2). Maintenance before seasonal use 1.Check if the air inlet/outlet of the indoor unit is clogged. 2.Check if the earthing is in good condition. 3.heck if the wiring is in good condition. 4.Check if the indicating lamp of the wired controller blinks after it is energized. Note: If there is something abnormal, please consult the after-sales serviceman. 3). Maintenance after seasonal use 1.Let the air conditioning unit run for half day under the fan mode to dry the inside of the unit. 2.If the unit is not to be used for a long time, please shut off the main power supply for energy conservation, at the same time, the power indicating lamp of the wired control will go off. 19

23 GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, Tel: ( ) Fax: ( )

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

Split Air Conditioner

Split Air Conditioner Split Air Conditioner Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If you have lost the Owner s Manual, please contact the local agent or visit

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

Reverse Cycle Inverter Split System Air Conditioner

Reverse Cycle Inverter Split System Air Conditioner Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

ROOM AIR CONDITIONER INSTALLATION MANUAL

ROOM AIR CONDITIONER INSTALLATION MANUAL ROOM AIR CONDITIONER INSTALLATION MANUAL ( Split Type) Please read this installation manual completely before installing the product When the power cord is damaged, replacement work shall be performed

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner F566272 Operating Instructions Air Conditioner CS-C18FFH CS-C28FFH CU-C18FFH CU-C28FFH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

More information

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with

More information

Instruction manual for Firstline FCS12000CH

Instruction manual for Firstline FCS12000CH Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Use and Care Manual. Model CPA12KH AIR CONDITIONER Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...

More information

Operating Instructions Split System Air Conditioner

Operating Instructions Split System Air Conditioner Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This

More information

LUCCI AIRFUSION QUEST II CEILING FAN

LUCCI AIRFUSION QUEST II CEILING FAN LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL Thank you for choosing our Air Conditioner. Please read this OWNER'S MANUAL carefully prior to use and keep it for further reference. CONTENTS Contents

More information

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)

More information

AIR-CONDITIONER SPLIT TYPE

AIR-CONDITIONER SPLIT TYPE FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,

More information

OPTIONAL SLENDER REMOTE CONTROL

OPTIONAL SLENDER REMOTE CONTROL DAIKIN ROOM AIR CONDITIONER Operation Manual OPTIONAL SLENDER REMOTE CONTROL BRC944A2B READ BEFORE OPERATION Safety Precautions...2 Names of Functions of Parts...4 Preparation before Operation...5 OPERATION

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Power supply unit Model: PAC-SC50KUA

Power supply unit Model: PAC-SC50KUA Building Air Conditioning Control System Power supply unit Model: PAC-SC50KUA Installation Manual Contents 1. Safety precautions... 1 2. Product feature... 2 1. Specification... 2 2. Appearance... 2 3.

More information

Wall Mounted Mini Split Heat Pump Air Conditioner

Wall Mounted Mini Split Heat Pump Air Conditioner Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFIHP-09-ID / KFHIP-09-OD KFHHP-12-ID / KFHHP-12-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus

More information

AIR CONDITIONER INSTALLATION MANUAL

AIR CONDITIONER INSTALLATION MANUAL FRANCAIS ESPAÑOL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring

More information

English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL. Français. R410A Split Series. Español MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU

English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL. Français. R410A Split Series. Español MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Español Français MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU Safety Precautions Read these Safety Precautions carefully to ensure

More information

Hi Wall Split Air Conditioners

Hi Wall Split Air Conditioners R22 220-240V ~, 50Hz Hi Wall Split Air Conditioners 53KHET 12-18-24 Cool Only 53QHET 12-18-24 Heat Pump INSTALLATION MANUAL Carrier is committed to continuously improving its products according to national

More information

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your

More information

VACUUM CLEANER INSTRUCTION MANUAL

VACUUM CLEANER INSTRUCTION MANUAL VACUUM CLEANER INSTRUCTION MANUAL MODEL: SVC9702 PLEASE READ THIS MANUAL CAREFULLY BEFORE USING AND KEEP IT PROPERLY FOR FUTURE USE 1 Safety Cautions: WARNING: To reduce the risk of fire, electrical shock,

More information

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with

More information

ALL IN ONE. Heat Pump Water Heater

ALL IN ONE. Heat Pump Water Heater ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

AIR CONDITIONER INSTALLATION MANUAL

AIR CONDITIONER INSTALLATION MANUAL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by

More information

Floor Type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA. English

Floor Type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA. English Floor Type Air-Conditioner MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA INSTALLATION MANUAL This manual only describes the installation of indoor unit. When installing the outdoor unit, refer to the installation manual

More information

INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER

INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER \ INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER Suitability: The IBIS caravan rooftop aircondioner is suitable for installation on caravans and motorhomes provided the roof structure

More information

INSTALLATION MANUAL E N G L I S H E-II-YDFC-0907 DIGITAL SCROLL SERIES AIR-CONDITIONER CEILING AND FLOOR TYPE

INSTALLATION MANUAL E N G L I S H E-II-YDFC-0907 DIGITAL SCROLL SERIES AIR-CONDITIONER CEILING AND FLOOR TYPE E N G L I S H E-II-YDFC-0907 INSTALLATION MANUAL DIGITAL SCROLL SERIES AIR-CONDITIONER CEILING AND FLOOR TYPE Models: YDFC-36C(A/B)5A YDFC-45C(A/B)5A YDFC-56C(A/B)5A YDFC-7C(A/B)5A YDFC-80C(A/B)5A YDFC-90C(A/B)5A

More information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform

More information

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS INSTALLATION HANDBOOK

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS INSTALLATION HANDBOOK SPLIT WLL MOUNTED TYPE IR CONDITIONERS INSTLLTION HNDBOOK Thank you for choosing our ir Conditioner. Please read this INSTLLTION HNDBOOK carefully prior to installing and keep it for further reference.

More information

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions

More information

DUCTED SPLIT TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

DUCTED SPLIT TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS LN-IM-01 DUCTED SPLIT TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS Please read this instruction sheet completely before installing the product. When the power supply location is wanted to replace, replacement

More information

Meaco 30L and Meaco 40L dehumidifier instruction manual

Meaco 30L and Meaco 40L dehumidifier instruction manual Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS

More information

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. White series

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. White series C88-VW-B UG [Update 10.05.12]_User guide 10/05/2012 09:40 Page 1 User Guide Vax Careline: (UK) 0844 412 8455 Bagless Cylinder White Get Cleaning... What s your Vax model number? (Located on the top flap

More information

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F

More information

ELECTRIC INSTANTANEOUS WATER HEATER

ELECTRIC INSTANTANEOUS WATER HEATER ELECTRIC INSTANTANEOUS WATER HEATER EPS - 3,5 EPS - 4,4 EPS - 5,5R Please, read and follow the installation and operating instructions carefully, to ensure the long life and reliable operation of this

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner

More information

WINDOW ROOM AIR CONDITIONER

WINDOW ROOM AIR CONDITIONER WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION

More information

LG Floor Standing Type Air Conditioner INSTALLATION MANUAL

LG Floor Standing Type Air Conditioner INSTALLATION MANUAL website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html LG Floor Standing Type Air Conditioner INSTALLATION MANUAL LG IMPORTANT Please read this installation manual completely before

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

BLACK TIE. Instructions Manual

BLACK TIE. Instructions Manual BLACK TIE EN Instructions Manual RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that

More information

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting

More information

SPLIT -TYPE ROOM AIR CONDITIONER

SPLIT -TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference SPLIT -TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing

More information

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split Multi System 16 SEER, Inverter System 9,000 to 18,000 BTU/Hr Single Split 4MXW8-A 4TXM6-A March2013 42 Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner P07-T10130 Operating Instructions Air Conditioner Indoor Unit CS-F24DD1E5 CS-F28DD1E5 CS-F34DD1E5 CS-F43DD1E5 CS-F50DD1E5 Outdoor Unit Inverter Model (HBE5 Series) CU-YL24HBE5 CU-YL28HBE5 CU-YL34HBE5 CU-YL43HBE5

More information

MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W

MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the

More information

CENTRAL AIR CONDITIONER SPLIT SYSTEM

CENTRAL AIR CONDITIONER SPLIT SYSTEM CENTRAL AIR CONDITIONER SPLIT SYSTEM WITH ELECTRONIC CONTROL SERIES DNC INSTALLATION INSTRUCTIONS Table of Contents 1. List of accessories provided with the air-conditioner... 1 2. General... 2 2.1 Indoor

More information

2-SLICE COOL TOUCH TOASTER

2-SLICE COOL TOUCH TOASTER 2-SLICE COOL TOUCH TOASTER PLA0405 Instruction Manual Due to on-going product improvements, specifications and accessories may change without notice. Actual product may differ slightly to that depicted.

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

Contents. PREPARING YOUR AIR CONDITIONER Safety Precautions... 3 View of the Indoor unit... 8

Contents. PREPARING YOUR AIR CONDITIONER Safety Precautions... 3 View of the Indoor unit... 8 Contents PREPARING YOUR AIR CONDITIONER Safety Precautions..................................................... 3 View of the Indoor unit................................................ 8 RECOMMENDATIONS

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,

More information

Split Air Conditioner

Split Air Conditioner Change for Life Split Air Conditioner Owner's Manual Residential Air Conditioners MODEL: GWH09MA-A3DNXXA GWC09MA-A3DNXXA GWH12MB-A3DNXXA GWC12MB-A3DNXXA GWH09MB-D3DNXXD GWC09MB-D3DNXXD GWH12MB-D3DNXXD

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

Split Air Conditioner

Split Air Conditioner Split nditioner plit itsplit ir onditioner Split Split Split Split Split User s WNER'S 'S ER'S For s: AWI/AWO-21HPR1 Delta AWI/AWO-25HPR1 Delta AWI/AWO-32HPR1 Delta AWI/AWO-53HPR1 Delta AWI/AWO-65HPR1

More information

Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) 216 3330 (55) 1163 6038

Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) 216 3330 (55) 1163 6038 Calor de Hogar Av Tecnológico 735, PB San Salvador Tizatlalli Metepec, 52172, Edo de México Teléfono (722) 216 3330 (55) 1163 6038 www.calordehogar.com servicio@calordehogar. com ventas@calordehogar.com

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Ramsond Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...

More information

Ductless Split Air Conditioner

Ductless Split Air Conditioner Ductless Split Air Conditioner Installation Manual Indoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W Outdoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G Table of Contents

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into

More information

Installation Manual MMD-AP0184H-E MMD-AP0244H-E MMD-AP0274H-E MMD-AP0364H-E MMD-AP0484H-E AIR CONDITIONER (MULTI TYPE) Indoor Unit.

Installation Manual MMD-AP0184H-E MMD-AP0244H-E MMD-AP0274H-E MMD-AP0364H-E MMD-AP0484H-E AIR CONDITIONER (MULTI TYPE) Indoor Unit. AIR CONDITIONER (MULTI TYPE) Indoor Unit Model name: Concealed Duct High Static Pressure Type MMD-AP0184H-E MMD-AP0244H-E MMD-AP0274H-E MMD-AP0364H-E MMD-AP0484H-E English SMMS Concealed Duct High Static

More information

Split Type Room Air Conditioner. KSWM units

Split Type Room Air Conditioner. KSWM units OWNER S MANUAL Split Type Room Air Conditioner KSWM units Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.

More information

CEILING CASSETTE DUCTLESS SYSTEM

CEILING CASSETTE DUCTLESS SYSTEM CEILING CASSETTE DUCTLESS SYSTEM INSTALLATION MANUAL Models: CAS12HP230V1AC -12,000 BTUH CAS18HP230V1AC -18,000 BTUH CAS24HP230V1AC - 24,000 BTUH Thank you for choosing the Gree Ceiling Cassette for your

More information

AIR CONDITIONER (SPLIT TYPE) Installation Manual. Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E. Model name: Concealed Duct High Static Pressure Type

AIR CONDITIONER (SPLIT TYPE) Installation Manual. Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E. Model name: Concealed Duct High Static Pressure Type AIR CONDITIONER (SPLIT TYPE) Indoor Unit Model name: Concealed Duct High Static Pressure Type RAV-SM2242DT-E RAV-SM2802DT-E Air conditioner (Split type) 1 English Manuel d installation Climatiseur (Type

More information

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL Centralized On-Off Remote Controller MC-821SC-E [FOR INSTLLER] INSTLLTION MNUL English [ [ π À À π ] E XEIPI IO O H IøN E KT T H [ [MONTÖR Ç N] MONTJ ELK TBI ÏÏËÓÈÎ [ДЛЯ УСТАНОВИТЕЛЯ] РУКОВОДСТВО ПО УСТАНОВКЕ

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

SYSTEM Inverter Air Conditioners

SYSTEM Inverter Air Conditioners OPERATION MANUAL SYSTEM Inverter Air Conditioners MODEL Ceiling Suspended type FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU Read these instructions carefully before installation. Keep this manual in a handy place

More information

SERVICE MANUAL Order No.WH0911S001V0

SERVICE MANUAL Order No.WH0911S001V0 SERVICE MANUAL Order No.WH0911S001V0 Electrical Water Heater Model No. FCD-JTSA50-III FCD-JTSA60-III FCD-JTSA70-III FCD-JTSA80-III! WARNING This service information is designed for experienced repair technicians

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477

More information

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0 Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view

More information

Wall Mounted Mini Split Heat Pump Air Conditioner

Wall Mounted Mini Split Heat Pump Air Conditioner Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFHHP-18-ID / KFHHP-18-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus Air. To ensure proper operation,

More information

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent

More information

CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS Please read this instruction sheet completely before installing the product. When the power cord is damaged, replacement work should be

More information

CEILING CASSETTE FAN COIL UNIT

CEILING CASSETTE FAN COIL UNIT CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL JG79A191H03 MSZ-GE06/09/12/15/18NA MSY-GE09/12/15/18NA When installing multi units, refer to the installation manual of the multi unit for outdoor

More information

National- Spencer Inc.

National- Spencer Inc. 9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

Important Safeguards

Important Safeguards Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the

More information

CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE

CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE Order No. PHAAM1003090C3 Outdoor Unit CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE Air Conditioner Please file and use this manual together with the service manual for Model No. CS-E7LKEW CU-E7LKE CS-E7LKEW

More information

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Installation manual MMU-AP0071MH2UL MMU-AP0091MH2UL MMU-AP0121MH2UL MMU-AP0151MH2UL MMU-AP0181MH2UL AIR CONDITIONER (MULTI TYPE) Indoor Unit

Installation manual MMU-AP0071MH2UL MMU-AP0091MH2UL MMU-AP0121MH2UL MMU-AP0151MH2UL MMU-AP0181MH2UL AIR CONDITIONER (MULTI TYPE) Indoor Unit AIR CONDITIONER (MULTI TYPE) Installation manual Indoor Unit Model name: Compact 4-way Cassette type MMU-AP0071MH2UL MMU-AP0091MH2UL MMU-AP0121MH2UL MMU-AP0151MH2UL MMU-AP0181MH2UL Installation manual

More information

DIGITAL SCROLL CENTRAL AIR CONDITIONER (OUTDOOR UNIT)

DIGITAL SCROLL CENTRAL AIR CONDITIONER (OUTDOOR UNIT) E-II-YDS-100-140-0907 ENGLISH INSTALLATION MANUAL DIGITAL SCROLL CENTRAL AIR CONDITIONER (OUTDOOR UNIT) YDS System, R410A, R407C & R22 / YDMH-C (B/A) 100&140 For correct installation, read this manual

More information

3 IN 1 BATHROOM HEATER

3 IN 1 BATHROOM HEATER 3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing

More information

15GAL STEEL OIL DRAIN WITH 110V PUMP

15GAL STEEL OIL DRAIN WITH 110V PUMP 15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

Installation Manual. BYD Wall-mounted AC Charging Box

Installation Manual. BYD Wall-mounted AC Charging Box Installation Manual BYD Wall-mounted AC Charging Box BYD Wall-mounted AC Charging Box Installation Manual Version/Revision: A/0 Dedicated Service Commitment from BYD Auto Dear valuable customers: We are

More information

DAIKIN ROOM AIR CONDITIONER FT50BSG FT60BSG MODELS. Operation Manual

DAIKIN ROOM AIR CONDITIONER FT50BSG FT60BSG MODELS. Operation Manual DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FT50BSG FT60BSG CONTENTS READ BEFORE OPERATION Safety Precautions... 2 Names of Parts Indoor unit, Opening the front grille... 5 Remote controller, Outdoor

More information

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English AIR CONDITIONER (SPLIT TYPE) Installation manual Branch kit 1:3 Model name: RBC-TRP100E Installation manual Air conditioner (Split type) 1 English Manuel d installation Climatiseur (Type split) 24 Français

More information

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Vax model number: Version 1.0

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Vax model number: Version 1.0 VRS5W Powermax User Guide V1.0.qxd:V1.0 23/7/10 15:35 Page 1 Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308 Carpet Washer Vax model number: VRS5W instruction manual Version 1.0 Please read carefully

More information