Industrial systems, installations and equipment and industrial products - Designation of signals - Part 1: Basic rules 2 IEC 62858:2015 PRV

Size: px
Start display at page:

Download "Industrial systems, installations and equipment and industrial products - Designation of signals - Part 1: Basic rules 2 IEC 62858:2015 PRV"

Transcription

1 Nr. Standard reference Title :2015 Industrial systems, installations and equipment and industrial products - Designation of signals - Part 1: Basic rules :2015 Lightning density based on lightning location systems (LLS) - General principles 3 TR 62874:2015 Guidance on the interpretation of carbon dioxide and 2-furfuraldehyde as markers of paper thermal degradation in insulating mineral oil :2015 Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires :2015 Specifications for particular types of winding wires - Part 0-9: General requirements - Enamelled rectangular aluminium wire :2009+AMD1:2015 CSV Winding wires - Test methods - Part 2: Determination of dimensions Amendment 1 - Winding wires - Test methods - Part 2: Determination of 2:2009/AMD1:2015 dimensions 8 Residual current devices with or without overcurrent protection for socketoutlets for household and similar uses 62640:2011+AMD1:2015 CSV 9 Amendment 1 - Residual current devices with or without overcurrent 62640:2011/AMD1:2015 protection for socket-outlets for household and similar uses :2015 Luminaires Part 2-5: Particular requirements Floodlights :2015 Digital addressable lighting interface - Part 201: Particular requirements for control gear - Fluorescent lamps (device type 0) :2015 RLV Digital addressable lighting interface - Part 201: Particular requirements for control gear - Fluorescent lamps (device type 0) :2015 Programmable components in electronic lamp controlgear - General and safety requirements :2015 Digital load side transmission lighting control (DLT) - Part 1: Basic requirements 15 TR 62710:2015 Residual current devices (RCDs) associated with additional functions(s) :2015 Primary batteries Part 1: General :2015 Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation :2015 RLV Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation :2015 Electrical and electronic installations in ships Electromagnetic compatibility (EMC) Ships with a metallic hull :2015 Passive filter units for electromagnetic interference suppression Part 3: Passive filter units for which safety tests are appropriate :2015 Device embedded substrate - Part 1-1: Generic specification - Test methods :2015 Surface mounting technology - Part 4: Classification, packaging, labelling and handling of moisture sensitive devices :2015 Connectors for electronic equipment - Tests and measurements - Part 1-101: Blank detail specification :2015 Organic light emitting diode (OLED) displays - Part 2-1: Essential ratings and characteristics of OLED display modules :2015 Nuclear power plants - Instrumentation and control systems important to safety - Design and qualification of isolation devices :2015 Photovoltaic concentrators (CPV) - Performance testing - Part 2: Energy measurement

2 : : : : TR 62964: :2012+AMD1:2015 CSV : :2015 RLV :2012/AMD1: :2010+AMD1:2012+AMD 2:2015 CSV 89:2010/AMD2:2015 Fibre optic interconnecting devices and passive components - Nonwavelength-selective fibre optic branching devices - Part 1: Generic specification Fibre optic active components and devices - Test and measurement procedures - Part 3: Optical power variation induced by mechanical disturbance in optical receptacles and transceiver interfaces Optical amplifiers - Test methods - Part 1-1: Power and gain parameters - Optical spectrum analyzer method Optical amplifiers - Test methods - Part 4-3: Power transient parameters - Single channel optical amplifiers in output power control Graphical symbols for use on equipment - Graphical symbols for multimedia equipment - Current practice Household and similar electrical appliances - Safety - Part 2-34: Particular requirements for motor-compressors Automatic electrical controls - Part 2-9: Particular requirements for temperature sensing control Automatic electrical controls - Part 2-9: Particular requirements for temperature sensing control Amendment 1 - Household and similar electrical appliances - Safety - Part 2-34: Particular requirements for motor-compressors Household and similar electrical appliances - Safety - Part 2-89: Particular requirements for commercial refrigerating appliances with an incorporated or remote refrigerant unit or compressor Amendment 2 - Household and similar electrical appliances - Safety - Part 2-89: Particular requirements for commercial refrigerating appliances with an incorporated or remote refrigerant unit or compressor 38 ISO//IEEE 15288:2015 Systems and software engineering - System life cycle processes Systems and software engineering - Content of life-cycle information items 39 ISO//IEEE 15289:2015 (documentation) Systems and software engineering - Engineering and management of 40 ISO//IEEE 23026:2015 websites for systems, software, and services information Systems and software engineering - Content management for product lifecycle, user and service management documentation 41 ISO//IEEE 26531:2015 Amendment 1 - Information technology - Telecommunications and ISO//IEEE information exchange between systems - Local and metropolitan area 42 1AE:2013/AMD1:2015 networks - Part 1AE: Media access control (MAC) security - Galois Counter Mode -- Advanced Encryption Standard-256 (GCM-AES-256) Cipher Suite Amendment 2 - Information technology - Telecommunications and ISO//IEEE information exchange between systems - Local and metropolitan area 43 1AE:2013/AMD2:2015 networks - Part 1AE: Media access control (MAC) security - Extended Packet Numbering Corrigendum 1 - Industrial communication networks - High availability 44 7:2011/COR1:2015 automation networks - Part 7: Ring-based Redundancy Protocol (RRP) Field device Integration (FDI) - Part 101-1: Profiles - Foundation Fieldbus :2015 H1 Field Device Integration (FDI) - Part 101-2: Profiles - Foundation Fieldbus :2015 HSE :2015 Field Device Integration (FDI) - Part 103-1: Profiles - PROFIBUS :2015 Field Device Integration (FDI) - Part 103-4: Profiles - PROFINET Field Devices Integration (FDI) - Part 109-1: Profiles - HART and :2015 WirelessHART :2015 Field device integration (FDI) - Part 1: Overview

3 :2015 Field Device Integration (FDI) - Part 2: FDI Client :2015 Field Device Integration (FDI) - Part 3: FDI Server :2015 Field Device Integration (FDI) - Part 4: FDI Packages :2015 Field Device Integration (FDI) - Part 5: FDI Information Model :2015 Field Device Integration (FDI) - Part 6: FDI Technology Mapping :2015 Field Device Integration (FDI) - Part 7: FDI Communication Devices 57 TR 61832:2015 Design and installation of on-line analyser systems - Guide to technical enquiry and bid evaluation :2014/COR1: : ISO : : : : : : : : TS : :2009/AMD2:2015/COR1 : /AMD1: /AMD1: /AMD1: :1989/COR2:2015+A MD1:1999+AMD2:2013 CSV Corrigendum 1 - Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery - Safety - Part 3-6: Particular requirements for transportable diamond drills with liquid system Resistance welding equipment - Part 1: Safety requirements for design, manufacture and installation Small-bore connectors for liquids and gases in healthcare applications -- Part 20: Common test methods Radionuclide imaging devices Characteristics and test conditions Part 2: Gamma cameras for planar, wholebody, and SPECT imaging Electrostatics - Part 4-6: Standard test methods for specific applications - Wrist straps Superconductivity - Part 21: Superconducting wires - Test methods for practical superconducting wires - General characteristics and guidance Electricity metering data exchange - The DLMS/COSEM suite - Part 4-7: DLMS/COSEM transport layer for IP networks Railway applications Direct current signalling monostable relays of type N and type C Electric vehicle wireless power transfer (WPT) systems Part 1: General requirements Determination of certain substances in electrotechnical products Part 7-1: Hexavalent chromium Presence of hexavalent chromium (Cr(VI)) in colourless and coloured corrosion-protected coatings on metals by the colorimetric method Safety of machinery - Electro-sensitive protective equipment - Part 4-3: Particular requirements for equipment using vision based protective devices (VBPD) - Additional requirements when using stereo vision techniques (VBPDST) Corrigendum 1 - Amendment 2 - Household and similar electrical appliances - Safety - Part 2-27: Particular requirements for appliances for skin exposure to optical radiation conditions Part 1-1: Test for vertical flame propagation for a single insulated wire or cable Apparatus conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kw pre-mixed flame conditions Part 1-3: Test for vertical flame propagation for a single insulated wire or cable Procedure for determination of flaming droplets/particles Corrigendum 2 - Degrees of protection provided by enclosures (IP Code)

4 Corrigendum 2 - Live working - Voltage detectors - Part 3: Two-pole lowvoltage type 3:2014/COR2: :2015 Maritime navigation and radiocommunication equipment and systems Digital interfaces Part 460: Multiple talkers and multiple listeners Ethernet interconnection Safety and security :2015 Characteristics of DAB receivers :2015 Application integration at electric utilities - System interfaces for distribution management - Part 8: Interfaces for customer operations 78 TS :2015 Framework for energy market communications - Part 504: Utilization of web services for electronic data interchanges on the European energy market for electricity :2015 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test :2015 RLV Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test :2015 Electricity metering equipment (AC) General requirements, tests and test conditions Part 31: Product safety requirements and tests 82 ISO/ 2382:2015 Information technology - Vocabulary 83 ISO/ TR 29194:2015 Information Technology - Biometrics - Guide on designing accessible and inclusive biometric systems 84 ISO/ Amendment 1 - Information technology - Universal Coded Character Set 10646:2014/AMD1:2015 (UCS) - Cherokee supplement and other characters 85 ISO/ Amendment 2 - Information technology - JPEG 2000 image coding system: 5:2003/AMD2:2015 Reference software 86 ISO/ Amendment 1 - Information technology - MPEG audio technologies - Part 2:2010/AMD1:2015 2: Spatial Audio Object Coding (SAOC) - SAOC conformance ISO/ :2010/AMD2:2015 ISO/ :2012/AMD2: ISO/ : ISO/ : ISO/ : ISO/ TR : ISO/ TS 30104: ISO/ TS : ISO/ TR 12182: ISO/ :2008/COR3:2015 ISO/ :2008/COR4:2015 Amendment 2 - Information technology - MPEG audio technologies - Part 2: Spatial Audio Object Coding (SAOC) - SAOC reference software Amendment 2 - Information technology - MPEG audio technologies - Part 3: Unified speech and audio coding - Reference software Information technology - High efficiency coding and media delivery in heterogeneous environments - Part 2: High efficiency video coding Information technology - Automatic identification and data capture techniques - Part 10: Crypto suite AES-128 security services for air interface communications Information technology - Automatic identification and data capture techniques - Part 13: Crypto suite Grain-128A security services for air interface communications Information technology - Dynamic adaptive streaming over HTTP (DASH) - Part 3: Implementation Guidelines Information Technology - Security Techniques - Physical Security Attacks, Mitigation Techniques and Security Requirements Information Technology - Programming languages, their environments, and system software interfaces - Floating-point extensions for C - Part 2: Decimal floating-point arithmetic Systems and software engineering - Framework for categorization of IT systems and software, and guide for applying it Corrigedum 3 - Information technology - ASN.1 encoding rules: Specification of Packed Encoding Rules (PER) Corrigendum 4 - Information technology - ASN.1 encoding rules: Specification of Packed Encoding Rules (PER)

5 98 ISO/ : ISO/ :2015 Information technology - Telecommunications and information exchange between systems - Magnetic field area network (MFAN) - Part 2: In-band Control Protocol for Wireless Power Transfer Information technology - User interface guidelines on menu navigation - Part 2: Navigation with 4-direction devices

IEC PROJETOS EM VOTAÇÃO JULHO E AGOSTO. IEC 60034-1 Ed.13: Rotating electrical machines - Part 1: Rating and performance.

IEC PROJETOS EM VOTAÇÃO JULHO E AGOSTO. IEC 60034-1 Ed.13: Rotating electrical machines - Part 1: Rating and performance. IEC PROJETOS EM VOTAÇÃO JULHO E AGOSTO IEC/TC 2 - Rotating machinery IEC 60034-1 Ed.13: Rotating electrical machines - Part 1: Rating and performance. IEC 60034-12 Ed.3: Rotating electrical machines -

More information

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS (PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,

More information

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03)

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03) 10.8.2002 Official Journal of the European Communities C 190/5 Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03) (Text with EEA relevance)

More information

Normen & Standards Industrie 4.0 IEEE Standards

Normen & Standards Industrie 4.0 IEEE Standards Normen & Standards Industrie 4.0 IEEE Standards Stand: Oktober 2015 IEEE 1872 * IEEE 2015 IEEE Standard Ontologies for Robotics and Automation 1872-2015 IEEE 1232.3 * IEEE 1232.3- IEEE Guide for the Use

More information

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012 Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012 CHANGE CONTROL RECORD: Version Date Action* Reason for Revision

More information

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec This value-packed VuSpec CD-ROM represents the most complete resource available for professional engineers looking for

More information

International Electrotechnical Commission Standards

International Electrotechnical Commission Standards International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354

More information

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting 12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company

Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company -1- Contents Page 1. What Is CCC? 3 2. Procedure for Judging If a Product Is Subject to

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60076-11 First edition 2004-05 Power transformers Part 11: Dry-type transformers This English-language version is derived from the original bilingual publication by leaving out

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60

More information

MEDDELELSER FRA NORSK ELEKTROTEKNISK KOMITE

MEDDELELSER FRA NORSK ELEKTROTEKNISK KOMITE INFORMERER Annonseringsdato: 2015-12-01 Meddelelse nummer: 209 MEDDELELSER FRA NORSK ELEKTROTEKNISK KOMITE IEC-normer og tekniske rapporter CENELEC Europanormer (EN) CENELEC Harmoniseringsdokumenter (HD)

More information

Nya och reviderade standarder 2014

Nya och reviderade standarder 2014 Här presenterar vi alla nya och reviderade standarder från år 2014. Standardlistan hittar du alltid på www.intertek.se/om-oss/intertekinfo Nya och reviderade standarder 2014 Standardnummer Namn Standarden

More information

784 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES. (REV 11-17-11) (FA 1-5-12) (7-12)

784 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES. (REV 11-17-11) (FA 1-5-12) (7-12) 784 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES. (REV 11-17-11) (FA 1-5-12) (7-12) SUBARTICLE 784-1.2.2 (of the Supplemental Specifications) is deleted and the 784-1.2.2 Networking Standards: Ensure

More information

TereScope Management Options

TereScope Management Options Introduction TereScope Management Options MRV Communications, Inc. offers a variety of management options for the TereScope FSO product family. Whether you are a Network Service Provider, Cellular Network

More information

Connectivity solutions for transport automation

Connectivity solutions for transport automation Connectivity solutions for transport automation The Belden product portfolio puts you on the fast track to highly available data communications in the transport automation industry. Uncompromising traffic

More information

Características. Starligh SA 9 de julio 1595 Córdoba Argentina - 0351-4809210 / 4119600

Características. Starligh SA 9 de julio 1595 Córdoba Argentina - 0351-4809210 / 4119600 Balun Activo - BALUN_ACT Características Single Channel Active Video Transmitter Full-motion color video signal up to 3900ft(1200m) via UTP cat5e/6 NTSC, PAL & SECAM video format compatible Real-time transmission

More information

for the Operation of Digital Cable Television Systems

for the Operation of Digital Cable Television Systems Technical Conditions Technical Conditions for the Operation of Digital Cable Television Systems Document No: ComReg 98/66R Date: December, 2002 An Coimisiún um Rialáil Cumarsáide Commission for Communications

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

GRU Purchasing Material Group Codes

GRU Purchasing Material Group Codes Title Code Trees and shrubs 10161500 Floral plants 10161600 Non flowering plants 10161800 Fertilizers and plant nutrients and herbicides 10170000 Pest control products 10190000 Minerals and ores and metals

More information

How To Understand The Electrical Power Supply Of A Power Supply System

How To Understand The Electrical Power Supply Of A Power Supply System 17 Circuit diagram symbols E 18 CIRCUIT DIAGRAM SYMBOLS electrical network elements three-phase line or cable single-phase line or cable short circuit earth electrode outgoing feeder supply incoming feeder

More information

Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards

Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards Abstract This Guide is an informative listing of selected terms and definitions found in IEC Glossary entry

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

for Communication Systems Protection EMI CD-ROM INCLUDED

for Communication Systems Protection EMI CD-ROM INCLUDED Krešimir Malarić EMI Protection for Communication Systems CD-ROM INCLUDED Contents Preface xiii CHAPTER 1 Communications Systems 1 1.1 Components of Communications Systems 1 1.2 Transmitter Systems 2 1.2.1

More information

Safety information. MSX-Box. ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany

Safety information. MSX-Box. ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany DIN EN ISO9001:2008 certified ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany Phone: +49 7229 1847 0 Fax: +49 7229 1847 222 E-mail: info@addi-data.com Safety information

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS STRUCTURED CABLING SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS INTRODUCTION In recent years, communications have taken on a crucial role in development for businesses. Communications

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK Field busses are industrial control systems using Programmable Logic lers (PLC) to control and manage field devices found in industrial environments. The communication

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10 TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified

More information

2013 / ZCI-2795331-DOC-00 OSRAM GmbH Marcel-Breuer-Str. 6 80807 München Germany. OSRAM LED module DC24B-XXXX. IEI See attached list

2013 / ZCI-2795331-DOC-00 OSRAM GmbH Marcel-Breuer-Str. 6 80807 München Germany. OSRAM LED module DC24B-XXXX. IEI See attached list OSRAM Q Document number: Manufacturer or representative: Address: Brand name or trade mark: Product type: Product designation: / ZCI-2795331-DOC-00 OSRAM GmbH Marcel-Breuer-Str. 6 80807 München Germany

More information

HCR3.2/.. Chipcard reader HOTEL SOLUTION

HCR3.2/.. Chipcard reader HOTEL SOLUTION s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages

More information

IEC and CISPR Standards

IEC and CISPR Standards IEC and CISPR Standards With thanks to Gideon Wiid, PhD student, and Paul van der Merwe EE Eng, 2 May, 2007 EMC Definition: Electromagnetic compatibility itself is defined as [1]: "the ability of an equipment

More information

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS 1 st Edition 29 th November 2013 Table of content a. Disclaimer... 3 b. Introduction... 3 c. Summary check lists for components...

More information

Australian Standard. Intruder alarm systems. Part 1: Systems installed in client s premises AS 2201.1 1998

Australian Standard. Intruder alarm systems. Part 1: Systems installed in client s premises AS 2201.1 1998 AS 2201.1 1998 Australian Standard Intruder alarm systems Part 1: Systems installed in client s premises This Australian Standard was prepared by Committee EL/31, Intruder Alarm Equipment and Installations.

More information

CORRECTIONAL SERVICES CANADA TECHNICAL SERVICES BRANCH ELECTRONIC SECURITY SYSTEMS ELECTRONIC ENGINEERING STANDARD FIXED OUTDOOR CAMERA ENCLOSURE

CORRECTIONAL SERVICES CANADA TECHNICAL SERVICES BRANCH ELECTRONIC SECURITY SYSTEMS ELECTRONIC ENGINEERING STANDARD FIXED OUTDOOR CAMERA ENCLOSURE CORRECTIONAL SERVICES CANADA TECHNICAL SERVICES BRANCH ELECTRONIC SECURITY SYSTEMS Revision 2 ELECTRONIC ENGINEERING STANDARD FIXED OUTDOOR CAMERA ENCLOSURE FOR USE IN FEDERAL CORRECTIONAL INSTITUTIONS

More information

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor Darul Ehsan, Malaysia Copyright of SKMM, 2007 FOREWORD

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

COFDM Transmission systems

COFDM Transmission systems COFDM Transmission systems www.vtq.de COFDM Radio Communication Appliance O.R.C.A - Trade Show Highlights Probably the fastest¹ COFDM video transmitter world s The brand new generation of O.R.C.A transmitters

More information

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13 Interfacing electrification and system reliability Roger White Professional Head of Electrification and Plant Rail Abstract Integration is the term given to ensuring that the different elements of an electrified

More information

Microcor Wireless Transmitter (MWT)

Microcor Wireless Transmitter (MWT) Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments

More information

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters Description Displayport combines the audio and video through an interface. It supports high resolution displays and multiple displays with a single cable, and increases the efficiency and bandwidth of

More information

UNIVERSITY OF CALICUT

UNIVERSITY OF CALICUT UNIVERSITY OF CALICUT SCHOOL OF DISTANCE EDUCATION BMMC (2011 Admission) V SEMESTER CORE COURSE AUDIO RECORDING & EDITING QUESTION BANK 1. Sound measurement a) Decibel b) frequency c) Wave 2. Acoustics

More information

- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).

- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF). Page 1 of 30 Page 2 of 30 1. Basic terminology - Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF). - Remote Element:

More information

RC8061 Pan and Tilt Camera Installation Guide

RC8061 Pan and Tilt Camera Installation Guide RC8061 Pan and Tilt Camera Installation Guide P/N: 956YM801GJ Document Version: 1.07 Copyright 2011 All Rights Reserved. All trademarks and trade names are the properties of their respective owners. i

More information

Security & Surveillance Cabling Systems

Security & Surveillance Cabling Systems Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.

More information

Using installed Fieldbus Wiring to carry Ethernet Communications

Using installed Fieldbus Wiring to carry Ethernet Communications Using installed Fieldbus Wiring to carry Ethernet Communications Modbus Plus, Data Highway, GE Genius, Profibus, ControlNet, DeviceNet, InterbusS and many other RS232 or RS4422 cables Key Issues when upgrading

More information

Understanding Network Video Security Systems

Understanding Network Video Security Systems Understanding Network Video Security Systems Chris Adesanya Panasonic System Solutions Company adesanyac@us.panasonic.com Introduction and Overview This session will provide vendor neutral introduction

More information

The car safety and more

The car safety and more Making electrotechnology work for you. The car safety and more IEC work in support of the automotive industry and electric cars Scope of IEC work Literally dozens of Technical Committees and thousands

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

Dear Customer! Thank you for choosing our product.

Dear Customer! Thank you for choosing our product. Dear Customer! Edition 1.4 Thank you for choosing our product. MIDI AMP CONTROLLER MAC-4.4 is an adaptor that enables to control (switch the channels, switch on/off other functions) the amps equipped with

More information

OPTICAL FIBER repeaters/ isolators

OPTICAL FIBER repeaters/ isolators OPTICAL FIBER repeaters/ isolators FUNCTINALITY AND RELIABILITY' Optical Fiber converters give the possibilità to extend on Optical Fiber (also at the same time) every type of network/bus (LAN/Ethernet,

More information

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014 Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014 CHANGE CONTROL RECORD: Version Date Action* Reason for Revision 1 4/14/2014

More information

EC-Declaration of Conformity Annex

EC-Declaration of Conformity Annex 2006/95/EC is given by the compliance with the following European Standard(s). If not EN 61347-1: + A1:2011 EN 61347-2-1. A1:2006 + Corrigendum:2006 EN 61347-2-2: 2012 EN 61347-2-3: 2011 EN 61347-2-7:

More information

MEDDELELSER FRA NORSK ELEKTROTEKNISK KOMITE

MEDDELELSER FRA NORSK ELEKTROTEKNISK KOMITE INFORMERER Annonseringsdato: 2015-09-01 Meddelelse nummer: 206 MEDDELELSER FRA NORSK ELEKTROTEKNISK KOMITE IEC-normer og tekniske rapporter CENELEC Europanormer (EN) CENELEC Harmoniseringsdokumenter (HD)

More information

T200, PTP/IEEE 1588 Grandmaster Clock and

T200, PTP/IEEE 1588 Grandmaster Clock and T200, PTP/IEEE 1588 Grandmaster Clock and NTP Time Server with high accuracy GPS receiver, OCXO or Rubidium oscillator 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 1 HEOL-T200 : PERFORMANCE

More information

4-20 ma Transmitters Alive and Kicking

4-20 ma Transmitters Alive and Kicking October, 1998 Control Engineering 4-20 ma Transmitters Alive and Kicking Fieldbus is everyone's hot topic, but 4-20 ma measurements are still the mainstay. Dave Harrold, CONTROL ENGINEERING Sidebar List

More information

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera MIC-BP4 Bi-Phase Converter Card for the MIC400 PTZ Camera Series Bosch Security Systems EN Installation and Operation Manual BP4 Bi-phase card Installation and Operation Manual AAAEN 2 MIC-BP4 Bi-Phase

More information

2015 / 9C1-3135351 -DOC-01 OSRAM GmbH Marcel-Breuer-Str. 6 80807 München Germany. Lamp controlgear HTi DALI 105/230-240.

2015 / 9C1-3135351 -DOC-01 OSRAM GmbH Marcel-Breuer-Str. 6 80807 München Germany. Lamp controlgear HTi DALI 105/230-240. OSRAM Document number: Manufacturer or representative: Address: Brand name or trade mark: Product type: Product designation: 2015 / 9C1-3135351 -DOC-01 OSRAM GmbH Marcel-Breuer-Str. 6 80807 München Germany

More information

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP VIEW SLX300 SpeakerLinX IP Zone Amplifier Installation and Setup Guide TM AVoIP ClearOne 5225 Wiley Post Way Suite 500 Salt Lake City, UT 84116 Telephone 1.800.283.5936 1.801.974.3760 Tech Sales 1.800.705.2103

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM

SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM ENGINEERING SPECIFICATION INTELLIGENT REPORTING FIRE DETECTION SYSTEM PART 1 GENERAL 1.1 DESCRIPTION A. This specification includes the furnishing,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60076-1 Edition 2.1 2000-04 Edition 2:1993 consolidated with amendment 1:1999 Power transformers Part 1: General This English-language version is derived from the original bilingual

More information

Poznan University of Technology Faculty of Electrical Engineering

Poznan University of Technology Faculty of Electrical Engineering Poznan University of Technology Faculty of Electrical Engineering Contact Person: Pawel Kolwicz Vice-Dean Faculty of Electrical Engineering pawel.kolwicz@put.poznan.pl List of Modules Academic Year: 2015/16

More information

SPL 2-00/-01 OPERATION INSTRUCTIONS

SPL 2-00/-01 OPERATION INSTRUCTIONS SPL 2-00/-01 OPERATION INSTRUCTIONS Powerline Ethernet Adapter 500 Mbps EN Read and keep Operation Instructions SPL 2-00/-01 Safety Notes Do NOT use this product near water, for example, in a wet basement

More information

Indoor / Outdoor Antenna

Indoor / Outdoor Antenna z300 High Precision NTP Time Server Indoor / Outdoor Antenna High Precision NTP Time Server with PoE (Indoor or Outdoor use) synchronized by GPS Revision 4 ZTI / 1 boulevard d'armor / BP 20254 / 22302

More information

2. What is the maximum value of each octet in an IP address? A. 128 B. 255 C. 256 D. None of the above

2. What is the maximum value of each octet in an IP address? A. 128 B. 255 C. 256 D. None of the above 1. How many bits are in an IP address? A. 16 B. 32 C. 64 2. What is the maximum value of each octet in an IP address? A. 128 B. 255 C. 256 3. The network number plays what part in an IP address? A. It

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT 1. SCOPE This Common Regulatory Objective, CRO, is applicable to Wireless Local Area

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

CLASSIFICATION SYSTEM BY FIELD AND SUB-FIELD OF EXPERTISE SUPPLIERS REGISTRY OF GOODS AND SERVICES ENAP GROUP OF COMPANIES I. Suppliers are classified in three groups: Classification Equipments, materials

More information

4.0 UPS dedicated to ICT for unmatched energy savings

4.0 UPS dedicated to ICT for unmatched energy savings 4.0 UPS dedicated to ICT for unmatched energy savings Introducing UPSaver by Borri, a new modular UPS series for the ICT industry, totally configurable, quickly scalable, with high efficiency and low TCO.

More information

MyM 3T. User Manual. English

MyM 3T. User Manual. English User Manual Compact unit with 2 DVB-T tuners MPEG-2 and MPEG-4 compliant 3 analogue modulators Two CI for decryption or multidecryption NICAM or A2 stereo 12-volt power supply Low power consumption MyM

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

DECT Gigaset N510 IP PRO

DECT Gigaset N510 IP PRO DECT Gigaset N510 IP PRO SUMMARY Summary... 1 1. System Features of the DECT Gigaset N510 IP Pro... 2 Base Station Gigaset N510 IP Pro... 2 Environmental Requirements... 3 The base should be placed in

More information

www.axon-cable.com Power distribution systems

www.axon-cable.com Power distribution systems www.axon-cable.com Power distribution systems Power distribution systems As vital components for electrical power distribution in telecommunication satellites and landbased weapon systems, the bus and

More information

Comprehensive Range of Industrial Products and Solutions

Comprehensive Range of Industrial Products and Solutions Comprehensive Range of Industrial Products and Solutions SAFETY AUTOMATION Micro Controllers Small Controllers Mid Range Controllers Large Automation Controllers Safety Programmable Controller Motion Controller

More information

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet. INTRODUCTION Fibre optics behave quite different to metal cables. The concept of information transmission is the same though. We need to take a "carrier" signal, identify a signal parameter we can modulate,

More information

EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION

EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION 1 EFFICIENT ELECTRICAL ENERGY TRANSMISSION

More information

EV charging. How EVs are charged? What are the most important international charging standards? Juha Vesa SESKO Development Manager 27.5.

EV charging. How EVs are charged? What are the most important international charging standards? Juha Vesa SESKO Development Manager 27.5. EV charging How EVs are charged? What are the most important international charging standards? Juha Vesa SESKO Development Manager 27.5.2016 1 Content Short survey on standardization What is a standard?

More information

www.curtisinstruments.com

www.curtisinstruments.com CANBUS I/O EXPANSION MODULE MODELS 56 / 56P FEATURES Eighteen multi-purpose I/O pins provide simple, flexible vehicle control system expansion. Two high-frequency (A, A) PWM driver outputs support a variety

More information

Two Novel Technologies Enabling IoT: Mobile Clouds and Visible Light Communications. Centre for Wireless Communications University of Oulu, Finland

Two Novel Technologies Enabling IoT: Mobile Clouds and Visible Light Communications. Centre for Wireless Communications University of Oulu, Finland Two Novel Technologies Enabling IoT: Mobile Clouds and Visible Light Communications Marcos Katz Centre for Wireless Communications University of Oulu, Finland Introduction: Internet of Things (IoT) What

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables

More information

www.klmtechgroup.com TABLE OF CONTENT

www.klmtechgroup.com TABLE OF CONTENT Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES

More information

MINIMUM TECHNICAL AND EXPLOITATION REQUIREMENTS FOR DIGITAL SOUND BROADCASTING DAB+ RECEIVER DESIGNED FOR POLAND

MINIMUM TECHNICAL AND EXPLOITATION REQUIREMENTS FOR DIGITAL SOUND BROADCASTING DAB+ RECEIVER DESIGNED FOR POLAND MINIMUM TECHNICAL AND EXPLOITATION REQUIREMENTS FOR DIGITAL SOUND BROADCASTING DAB+ RECEIVER DESIGNED FOR POLAND Version 1.0 Prepared by: Technical Subgroup of Digital Sound Broadcasting Committee National

More information

Interface Level And Point Level Analyzers & Sensors

Interface Level And Point Level Analyzers & Sensors Interface Level And Point Level Analyzers & Sensors Model 2511 Analyzer Model 2505 System Model 2120 System Royce now offers a complete line of Interface Level and Point Level Analyzers that make it possible

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Ontario Electrical Safety Code 25 th Edition/ 2012

Ontario Electrical Safety Code 25 th Edition/ 2012 Ontario Electrical Safety Code 25 th Edition/ 2012 Ted Olechna Director, Codes and Standard Chief Engineer 1 What I Will Cover ESA s role is as the regulator Highlight of 2012 Code changes The Code and

More information

Marine HF SSB Installation and Grounding. Anatomy of the Best Tour 2006

Marine HF SSB Installation and Grounding. Anatomy of the Best Tour 2006 Marine HF SSB Installation and Grounding Anatomy of the Best Tour 2006 Marine HF Installation Considerations This document is meant to be an overview of Marine HF radio installation For detailed installation

More information

not a Web- based application. not self-contained, closed products. Please refer to the attached VPAT Please refer to the attached VPAT

not a Web- based application. not self-contained, closed products. Please refer to the attached VPAT Please refer to the attached VPAT Apple Cinema Display Standards Subpart 1194.21 Software applications and operating systems. 1194.22 Web-based intranet and internet information and applications. 1194.23 Telecommunications products. 1194.24

More information

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and

More information

Revistas IEEE ANII 2009

Revistas IEEE ANII 2009 Revistas IEEE ANII 2009 Advanced Packaging, IEEE Transactions on Aerospace and Electronic Systems Magazine, IEEE Aerospace and Electronic Systems, IEEE Transactions on American Institute of Electrical

More information

A Look at Emerging Standards in Video Security Systems. Chris Adesanya Panasonic Network Systems Company Chris.Adesanya@us.panasonic.

A Look at Emerging Standards in Video Security Systems. Chris Adesanya Panasonic Network Systems Company Chris.Adesanya@us.panasonic. A Look at Emerging Standards in Video Security Systems Chris Adesanya Panasonic Network Systems Company Chris.Adesanya@us.panasonic.com Standards Standards are published documents that establish specifications

More information

OC810 Outdoor Camera Setup Guide

OC810 Outdoor Camera Setup Guide OC810 Outdoor Camera Setup Guide P/N: 957YU60001 Document Version: 1.0 Copyright 2010. All Rights Reserved. All trademarks and trade names are the properties of their respective owner i Package Contents

More information

Fiber Optic High Density ACC Sensor System Faser Optisches Beschleunigungs-Messsystem

Fiber Optic High Density ACC Sensor System Faser Optisches Beschleunigungs-Messsystem End Winding Remote unit PNR: 9600.30.180 Remote unit and 6 x One-Axis optical, MIC-Accelerometer Frequency response 1 1000 Hz Easy installation on the end-winding High voltage electrical insulation between

More information

OC810 Outdoor Camera Installation Guide

OC810 Outdoor Camera Installation Guide OC810 Outdoor Camera Installation Guide P/N: 957YU601GJ Document Version: 1.0 Copyright 2011. All Rights Reserved. All trademarks and trade names are the properties of their respective owner i Package

More information

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D ************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D INTRODUCTION Power Acoustik amplifiers provide high-performance

More information