Features and Benefi ts

Size: px
Start display at page:

Download "Features and Benefi ts"

Transcription

1 haracterized ontrol Valves (V) eatures and enefi ts QUL PRNTG VLV HRTRISTI TURS Patented Technology NIT O TH LIMO HRTRIZING IS qual percentage flow characteristic. xcellent control stability assured with the characterizing disc. v values equal to v values of globe valves the same size. The need for multiple pipe reduction is usually eliminated. etter control prevents hunting of the control loop, increasing life span of actuator and valve. Thermal isolating adapter between flange and actuator. asy direct coupling of actuator with a single screw. Perpendicular mounting flange and square drive head eliminate lateral forces on the stem. low-out proof stem with thrust-bearing Teflon disc and double O-ring design for long service life.* Non-corroding chrome-plated brass or stainless ball. In order to ensure good stability of control, it is essential for a control valve to have an equal percentage characteristic. This type of characteristic produces a linear variation in thermal output according to the amount of opening of the valve (also known as the system characteristic). Under normal testing conditions a conventional ball valve exhibits an S-shaped characteristic. When it is installed in a real system, however, this characteristic is seriously deformed because, compared with its nominal size, a ball valve possesses an extremely high flow coefficient. Whether used with or without pipe reducers or a reduced bore, they do not normally allow stable regulation of the thermal capacity. elimo s unique haracterized ontrol Valve (V) is very different. special characterizing disc inside the valve gives it an equal percentage characteristic which is comparable with that of a globe valve of the same nominal size. The flow (the v value) is reduced to the required value by a combination of the hole in the ball and the shaped aperture in the disc. The increase in flow as the valve is opened is very slow and controlled. This produces better part-load behavior and improved stability of control while also optimizing energy consumption. Vent holes reduce condensation build-up. orged brass valve body no pin-hole leaks. haracterizing disc made of Tefzel known for excellent strength and chemical resistance. Teflon seats with O-rings provide constant seating force against the ball and reduce torque requirement. ctuator can be mounted in four different positions. * esigned for service life of over 100,000 full cycles. Teflon and Tefzel are both registered trademarks of upont US N LTIN MRI 1

2 eature / enefits haracterized ontrol Valves (V) OORINT MOTORIZ OPRTION The optimum functionality of the elimo V is assured by properly coordinating its actuation with MT. Specially developed rotary actuators provide the necessary precision for modulating, floatingpoint, and on/off methods of control. ll Vs are supplied with the appropriate rotary actuator to provide the close-off and operation desired. OPTIMIZ OR ONTROL The elimo V marries known technology with an innovative development the unique characterizing disc. The marriage of V and MT technologies has produced a range of valuable features which surpass the capabilities of globe valves at a very attractive price level: n equal-percentage valve characteristic Unlike a globe valve, no sudden change in inlet flow upon opening xcellent stability of control v values comparable with those of globe valves of the same size or larger Higher close-off ratings than standard globe valves 100% tight shut-off on two-way valves means NO leak-by unlike globe valves that have NSI IV shutoff (leakage rate of 0.01% of the v rating) Three-way valve can be piped in mixing or diverting application low haracteristics of onventional all Valves versus LIMO HRTRIZ ONTROL VLVS Stable control is hard to achieve esirable valve authority is not achieved Series Two-way ½ to 3 3 Series Three-way ½ to Mixing*/iverting 6 Series Two-way langed ½ to 6 Service: v Range Material: ontrol: hilled/hot water, 60% glycol Stainless trim or rass trim On/Off, loating, -10 V Multi-unction Technology Spring Return or Non-Spring Return Mixing* (Not for use in change over applications) esirable qual Percent low and resulting heat output is achieved with linear results

3 Sizing/Selection haracterized ontrol Valves (V) -Way Valve low Rate for Water pplications (Gallons Per Minute, GPM) v Maximum Rating Inches N mm -Way V Pressure rop cross the Valve 1 psi psi 3 psi 4 psi 5 psi 6 psi 7 psi 8 psi 9 psi 10 psi 0.3 ½ 15 07() ½ 15 08() ½ 15 09() ½ 15 10() ½ 15 11() ½ 15 1() ½ 15 13() ½ 15 14() ½ 15 15()* ½ 15 16()* ¾ 0 17() ¾ 0 18() ¾ 0 19() ¾ 0 0()* ¾ 0 1()* * ¼ ¼ 3 30* ¼ ¼ 3 3* ½ ½ ½ 40 40* * * ½ ½ ½ ½ ½ 65 65* * ½ S ½ S S " S " S " S GPM = v x Δp *Models with no characterizing disc. The influence of the pipe geometry due to reduced flow is negligible for all valves 57 v and below with characterizing discs US N LTIN MRI 3

4 Sizing/Selection haracterized ontrol Valves (V) 3-Way Valve low Rate for Water pplications (Gallons Per Minute, GPM) v Maximum Rating Inches N mm 3-Way V Pressure rop cross the Valve 1 psi psi 3 psi 4 psi 5 psi 6 psi 7 psi 8 psi 9 psi 10 psi 0.3 ½ () ½ () ½ () ½ () ½ () ½ 15 31() ½ () ½ ()* ½ ()* ¾ 0 317() ¾ 0 318() ¾ 0 30()* ¾ 0 31()* * ¼ ¼ ¼ ½ ½ ½ ½ GPM = v x Δp * = Models with no characterizing disc. The influence of the pipe geometry due to reduced flow is negligible for all valves 83 v and below with characterizing discs US N LTIN MRI

5 Set-up and Wiring Instructions haracterized ontrol Valves (V) ST-UP TR4-3-T US TR4-3 US On/Off or loating Point ctuators Power to pin will drive valve W. Power to pin 3 will drive valve W. -WY VLV SPIY UPON ORRING Power to pin will drive valve W. Power to pin 3 will drive valve W. 3-WY VLV SPIY UPON ORRING NON-SPRING RTURN Stays in Last Position TR4-SR-T US TR4-SR US Proportional Type ctuators LR4 (-3), MT, SR LRX4 (-3), MT, SR R4 (-3), MT, SR RX4 (-3), MT, SR loating Point or Proportional Type ctuators N: losed to, will open as voltage increases. Power to pin will drive valve W. Power to pin 3 will drive valve W. The above will function when the directional switch is in the 1 position, to reverse select the 0 position. NO: Open to, will close as voltage increases. (an be chosen with switch inside terminal block of actuator.) NO: Open to, will close as voltage increases or power applied. (an be chosen with W/W switch.) N: losed to, will open as voltage increases. Power to pin will drive valve W. Power to pin 3 will drive valve W. The above will function when the directional switch is in the 1 position, to reverse select the 0 position. NO: Open to, will close as voltage increases. (an be chosen with switch inside terminal block of actuator.) NO: Open to, will close as voltage increases or power applied. (an be chosen with W/W switch.) TR4 L4 US R4 NO/O Valve: Open to will drive closed. Spring ction: Will spring open to upon power loss. N/ Valve: losed to will drive open. Spring ction: Will spring closed to upon power loss. NO/O Valve: Open to will drive closed. Spring ction: Will spring open to upon power loss. N/ Valve: losed to will drive open. Spring ction: Will spring closed to upon power loss. SPRING RTURN Note ail Position T (-3), MT, SR L (-3), MT, SR SR R, MT loating Point or Proportional Type ctuators GNRL WIRING INSTRUTIONS N/O Valve: losed to will drive open. Spring ction: Will spring open to upon power loss. WRNING The wiring technician must be trained and experienced with electronic circuits. isconnect power supply before attempting any wiring connections or changes. Make all connections in accordance with wiring diagrams and follow all applicable local and national codes. Provide disconnect and overload protection as required. Use copper, twisted pair, conductors only. If using electrical conduit, the attachment to the actuator must be made with flexible conduit. lways read the controller manufacturer's installation literature carefully before making any connections. ollow all instructions in this literature. If you have any questions, contact the controller manufacturer and/or elimo. Transformer(s) elimo actuators require a 4 V class transformer and draws a maximum of 10 V per actuator. The actuator enclosure cannot be opened N/ or NO/ Valve: losed to or Open to. (an be chosen with W/W switch.) Spring ction: Will spring closed to upon power loss. NO/O Valve: Open to Spring ction: Will spring open to upon power loss. (NO action can be chosen with W/W switch.) N/O Valve: losed to will drive open Spring ction: Will spring open to upon power loss. N/ or NO/ Valve: losed to or Open to. (an be chosen with W/W switch.) Spring ction: Will spring closed to upon power loss. NO/O Valve: Open to Spring ction: Will spring open to upon power loss. (NO action can be chosen with W/W switch.) in the field, there are no parts or components to be replaced or repaired. M directive: 89/336/ Software class : Mode of operation type 1 Low voltage directive: 73/3/ UTION It is good practice to power electronic or digital controllers from a separate power transformer than that used for actuators or other end devices. The power supply design in our actuators and other end devices use half wave rectification. Some controllers use full wave rectification. When these two different types of power supplies are connected to the same power transformer and the commons are connected together, a short circuit is created across one of the diodes in the full wave power supply, damaging the controller. Only use a single power transformer to power the controller and actuator if you know the controller power supply uses half wave rectification US N LTIN MRI 5

6 low, Operation and Installation haracterized ontrol Valves (V) LOW PTTRNS -way haracterized ontrol Valves (elimo Series) (elimo 6 Series) low irection Two-way valves should be installed with the disc upstream. Upstream ownstream 3-way haracterized ontrol Valves MIXING (Not for use in change over applications (elimo 3 Series) IVRTING The -port must be piped to the coil to maintain proper control. INORRT PIPING The -port must be piped to the coil to maintain proper control. Three-Wa y Mixing Valve Piping iagra m ( Inputs, 1 Output) Return oil Supply Three-Way iver ting Valve Piping iagram (1 Input, Outputs) Return oil Supply Note Valve Porting! The -port must be piped to the coil! Not the -port! low is not possible from to. If -port is not piped as the common port, the valve must be re-piped. It is good practice to install a balancing valve in the bypass line. These valves are intended for closed loop systems. o not install in an open loop system or in an application that is open to atmospheric pressure. OPRTION/INSTLLTION ORRT PIPING -way valves should be installed with the disc upstream. If installed with disc downstream, flow curve will be deeper. If installed backwards it is NOT necessary to remove and change. No damage or control problems will occur. 3-WY VLVS MUST PIP ORRTLY. They can be mixing or diverting. Mixing is the preferred piping arrangement. iverting* (Not for use in change over applications) The LIMO haracterized ontrol Valve is a ONTROL valve, not a manual valve adapted for actuation. The control port is the -port. It is similar to the globe valve in that the middle port is the or bypass port. The common port is on the main opposite the -port. These diagrams are for typical applications only. onsult engineering specification and drawings for particular circumstances. RU -PORT LOW Note: The -port flow of the 3-way V is lower than that of the -port. In most applications this is beneficial since the reduced flow compensates for the inexistent pressure drop across the coil in the bypass mode. Therefore, proper sizing is important to avoid flow noise in particular when the system is designed with constant speed pumps. Please refer to our valve sizing and selection guidelines. The flow velocity in the pipe upstream and downstream of the valve should be considered as well. The typical HV design maximum flow is 4 to 8 ft/s to avoid noise issues. lso, the pipe reduction factor must be considered and can be found on pages 3 and 4. Pipe reducers decrease the v value of a valve and consequently increase the pressure drop across the valve, a situation that could lead to noise or a lower than designed flow. iverting* (Not for use in change over applications) US N LTIN MRI

7 Nomenclature haracterized ontrol Valve (V) 09 LRX 4 -MT Valve = -way 3 = 3-way 6 = -way langed Valve Size = ½ -3 Trim Material = rass lank = Stainless Steel Trim ctuator Type Non-Spring Return TR LR LRX R RX LRQ... NRQ... Spring Return TR L R... lectronic ail-safe GK... Power Supply 4 = 4 V/ 10 = 10 V* 30 = 30 V ontrol lank = On/Off, loating -3 = loating Point -SR = -10 V -MT = Multi-unction Technology -MT95 = Ω -T = Terminal Strip -S = uilt-in uxiliary Switch N4 = NM 4X, UL Type 4X, IP 66/67 nclosure ORRING XMPL 1 hoose the valve actuator combination. 09+LRX4-MT Specify preference or confi guration. Non-Spring Models NO = Normally Open N = Normally losed Spring Return Models NO/O = Normally Open/ail Open NO/ = Normally Open/ail losed N/O = Normally losed/ail Open N/ = Normally losed/ail losed See settings Refers to valve ports to. 3 Set-Up +NO or MT orders only - select programming code +Tagging (if needed) P (01) P-100xx (xx) ontrol voltage applications P-00xx (Wxx) Pulse width modulation applications P-300xx (xx) loating Point applications P-400xx (Jxx) On/Off applications X-XXXXX reate custom MT confi guration code X-XXXXX reate custom MT confi guration in the fi eld with MT-actuator P software 4 oes order require tagging? Tagging: Valves may be tagged per customer specification. xample: HU-1 U- 5 omplete Ordering xample: 09+LRX4-MT+NO+01 *T, LR and R Series has 100 to 40 V nominal power supply US N LTIN MRI 7

8 8 This Page Intentionally Left lank

9 Series, -Way, haracterized ontrol Valve hrome Plated rass all and rass Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VV box re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable fl ow. Technical ata Service chilled or hot water, 60% glycol low characteristic -port equal percentage ontrollable low Range 75 Sizes ½, ¾ Type of end fi tting NPT female ends Materials: ody forged brass, nickel plated all chrome plated brass Stem nickel plated brass Seats PT haracterizing disc Tefzel Packing PM O-rings, lubricated ody pressure rating 600 psi Media temp. range 0 to 50 [-18 to 10 ] lose off pressure 00 psi Maximum differential 50 psi for typical applications pressure (ΔP) Leakage 0% for to xternal leakage according to N 166-1:003 v rating -port: see product chart for values Tefzel is a registered trademark of upont Valve Nominal Size Type Suitable ctuators v Inches N [mm] -way NPT Non-Spring Spring 0.3 ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ ¾ ¾ ¾ ¾ ¾ 0 1* *Models without characterizing disc TR Series LR Series T Series L Series imensions Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] ½ [60.8] 1.39 [35.] 1-16 ½ [60.8] 1.78 [45.] 17-1 ¾ 0.73 [69.3] 1.87 [47.4] low Patterns WayValve

10 3 Series, 3-Way, haracterized ontrol Valve hrome Plated rass all and rass Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VV box re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable or constant flow. * (Not for use in change over applications) Technical ata Service chilled or hot water, 60% glycol low characteristic -port equal percentage -port modifi ed for constant common port fl ow ontrollable low Range 75 Sizes ½, ¾ Type of end fi tting NPT female ends Materials: ody forged brass, nickel plated all chrome plated brass Stem nickel plated brass Seats PT haracterizing disc Tefzel Packing PM O-rings, lubricated ody pressure rating 600 psi Media temp. range 0 to 50 [-18 to 10 ] lose off pressure 00 psi Maximum differential 50 psi for typical applications pressure (ΔP) Leakage 0% for to <.0% for to xternal leakage according to N 166-1:003 v rating -port: see product chart for values -port: 70% of to v Tefzel is a registered trademark of upont imensions Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] ½ [61.1] 1.39 [35.] 1.0 [30.6] ½ [60.4] 1.78 [45.] 1.9 [3.8] ¾ 0.73 [69.3] 1.87 [47.4] 1.47 [37.3] 3WayValve Valve Nominal Size Type Suitable ctuators v Inches N [mm] 3-way NPT Non-Spring Spring 0.3 ½ ½ ½ ½ ½ ½ ½ ½ ½ ¾ ¾ ¾ ¾ 0 31 *Models without characterizing disc TR Series LR Series T Series L Series low Patterns Port must be piped to the bypass leg. 10

11 Series, -Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VV box re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable fl ow. Technical ata Service chilled or hot water, 60% glycol low characteristic -port equal percentage ontrollable low Range 75 Sizes ½, ¾, 1, 1¼, 1½,, ½, 3 Type of end fi tting NPT female ends Materials: ody forged brass, nickel plated all stainless steel Stem stainless steel Seats PT haracterizing disc Tefzel Packing PM O-rings, lubricated ody pressure rating 600 psi ½ - 1¼ (30) 400 psi 1¼ (31) - 3 Media temp. range 0 to 50 [-18 to 10 ] lose off pressure 00 psi ½ - (50) 100 psi (51) - 3 Maximum differential 50 psi for typical applications pressure (ΔP) Leakage 0% for to xternal leakage according to N 166-1:003 v rating -port: see product chart for values Tefzel is a registered trademark of upont imensions Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] ½ [61.1] 1.39 [35.] 1-16 ½ [60.4] 1.78 [45.] 17-1 ¾ 0.73 [69.3] 1.87 [47.4] [78.4] 1.87 [47.4] ¼ [94.6] 1.87 [47.4] ¼ [94.6].04 [51.9] ½ [98.5].04 [51.9] [107.0].7 [57.7] [15.].73 [69.5] ½ [140.9].73 [69.5] [147.9].73 [69.5] WayValve-07-0 Valve Nominal Size Type Suitable ctuators v Inches N [mm] -Way NPT Non-Spring Spring 0.3 ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ ¾ ¾ ¾ ¾ ¾ 0 1* * 10 1¼ ¼ 3 30* 5 1¼ ¼ 3 3* 19 1½ ½ ½ 40 40* * * 60 ½ ½ ½ ½ ½ 65 65* * *Models without characterizing disc low Patterns TR Series LR Series R Series NR...N4 Series R...N4 Series T Series L Series Series 11

12 3 Series, Three Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VV box re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable or constant flow. * (Not for use in change over applications) Technical ata Service chilled or hot water, 60% glycol low characteristic -port equal percentage -port modifi ed for constant common port fl ow ontrollable low Range 75 Sizes ½, ¾, 1, 1¼, 1½, Type of end fi tting NPT female ends Materials: ody forged brass, nickel plated all stainless steel Stem stainless steel Seats PT haracterizing disc Tefzel Packing PM O-rings, lubricated ody pressure rating 600 psi ½ psi 1¼ - Media temp. range 0 to 50 [-18 to 10 ] lose off pressure 00 psi ½ - Maximum differential 50 psi for typical applications pressure (ΔP) Leakage 0% for to <.0% for to xternal leakage according to N 166-1:003 v rating -port: see product chart for values -port: 70% of to v Tefzel is a registered trademark of upont imensions Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] ½ [61.1] 1.39 [35.] 1.0 [30.6] ½ [60.4] 1.78 [45.] 1.9 [3.8] ¾ 0.73 [69.3] 1.87 [47.4] 1.47 [37.3] [78.4] 1.87 [47.4] 1.59 [40.3] ¼ [100.6].7 [57.7].14 [54.3] ½ [111.6].51 [63.7].40 [61.1] [14.5].73 [69.5].74 [69.7] 3WayValve Valve Nominal Size Type Suitable ctuators v Inches N [mm] 3-Way NPT Non-Spring Spring 0.3 ½ ½ ½ ½ ½ ½ ½ ½ ½ ¾ ¾ ¾ ¾ * 10 1¼ ¼ ¼ ½ ½ ½ ½ *Models without characterizing disc low Patterns Port must be piped to the bypass leg. TR Series LR Series R Series NR...N4 Series R...N4 Series T Series L Series Series 1

13 6 Series, Two Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VV box re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable or constant fl ow. Technical ata Service chilled or hot water, 60% glycol low characteristic -port equal percentage ontrollable low Range 75 Sizes ½, 3, 4, 5, 6 Type of end fi tting pattern to mate with NSI 15 fl ange Materials: ody cast iron - GG5 all stainless steel Stem stainless steel Seats PT haracterizing disc stainless steel Packing PM O rings, lubricated ody pressure rating according to NSI 15, standard class Media temp. range 0 to 48 [-18 to +10 ] lose off pressure 100 psi Maximum differential 50 psi pressure (ΔP) Leakage 0% for to v rating -port: see product chart for values Valve Nominal Size Type Suitable ctuators v Inches N [mm] -way lange Non-Spring Spring 70 ½" S ½" S " S " S " S " S-400 low Pattern R Series GR Series -way 650 to 6600 haracterized ontrol Valves R Series low irection lectronic ail-safe GKR Series imensions Valve ody Nominal Pipe Size 650S ½" [65] Top lange esign lange iameter ace-to-ace Length Height 7.50" [190.5] 5.50" [139.7] 8.10" [05.4] 6300S 3" [80] 8.00" [03.] 6.60" [167.6] 8.40" [13.1] 6400S 4" [100] " [8.6] 8.30" [10.8] 9.30" [35.9] 6500S 5" [15] 10.00" [54.0] 10.30" [61.6] 10.50" [66.4] 6600S 6" [150] 11.00" [79.4] 1.50" [317.5] 11.70" [96.9] Upstream ownstream olt ircle iameter lange Thickness Minimum olt Hole iameter Number of olt Holes 5.50" [139.7] 0.75" [19.05] 0.75" [19.05] " [15.4] 0.75" [19.05] 0.75" [19.05] " [190.5] 0.94" [3.88] 0.75" [19.05] " [15.9] 0.94" [3.88] 0.88" [.35] " [41.3] 1.00" [5.40] 0.88" [.35] 8 NOTS: 1) lange bolt pattern matches NSI class 15 fl anges (not NSI/SM rated) ) Maximum allowable working pressure: 100 PSIG 3) It is not recommended to connect raised-face fl anges to flat-faced fl anges 13

14 haracterized ontrol Valve Product Range Overview.., 3.., -way, 3-way, Stainless Steel all and Stem Valve Nominal Size Type Suitable ctuators v Inches N [mm] -way NPT 3-way NPT Non-Spring Return Spring Return NM 4X 0.3 ½ 15 07() 307() 0.46 ½ 15 08() 308() 0.8 ½ 15 09() 309() 1. ½ 15 10() 310() V 1.9 ½ 15 11() 311() 3 ½ 15 1() 31() 4.7 ½ 15 13() 313() 7.4 ½ 15 14() 10 ½ 15 15() 315() 14 ½ 15 16()* 316()* 4.7 ¾ 0 17() 317() 7.4 ¾ 0 18() 318() 10 ¾ 0 19() 14 ¾ 0 0()* 14 ¾ 0 30() 4 ¾ 0 1()* 31()* TR Series LR Series TR Series L Series NR Series qual Percentage haracteristic Mode of Operation The haracterized ontrol Valve is operated by a rotary actuator. The actuators are controlled by a standard voltage for on/off control or a proportional signal or 3-point control system which move the ball of the valve to the position dictated by the control system. Product eatures The equal-percentage characteristic of the flow is ensured by the integral characterizing disc. This characteristic provides linear heating or cooling output from the coil improving energy efficiency and comfort. ctuator Specifications ontrol type on/off, floating point, -10 V, multi-function technology (MT) Manual override TR, LR, R, NR, R series lectrical connection 3 ft [1m] cable with ½ conduit fitting or covered screw terminal strip * 35* 10 1¼ ¼ 3 30* 10 1¼ ¼ ¼ ¼ 40 3* 19 1½ ½ ½ 40 40* ½ * * R Series R Series R Series Valve Specifications Service chilled or hot water, 60% glycol low characteristic -port equal percentage -port modifi ed for constant common port fl ow ontrollable fl ow range 75 Sizes ½ - Type of end fi tting NPT female ends Materials ody forged brass, nickel plated all stainless steel or chrome Stem stainless steel or chrome Seats Tefl on PT haracterizing disc ½ - 1 ½ (-way) Tefzel ½ -1 (3-way) Tefzel (-way) stainless steel 1¼ - (3-way) stainless steel Packing PM O-rings, lubricated Media temp range 0 to 50 [-18 to 10 ] ody pressure rating ½ - 1¼ (30) 600 psi 1¼ (31) - (51) 400 psi lose-off pressure 00 psi Maximum differential pressure (ΔP) 50 psi Leakage 0% for to <.0% for to v rating/gpm port: see product chart above for values port: 70% of to v Tefzel and Tefl on are registered trademarks of upont * Models without characterizing discs. () Models with chrome plated brass ball and brass stem * 3-Way Valves not for use in change over applications 14

15 haracterized ontrol Valve Product Range Overview 6.., -way, Stainless Steel all and Stem Valve Nominal Size Type Suitable ctuators N -way v Inches [mm] NPT 70 ½ S ½ S S S S S-400 Non-Spring Return R GR Spring Return R lectronic ail-safe GKR V qual Percentage haracteristic pplications Water-side control of heating and cooling systems for HU supply, cooling towers and chillers. Mode of Operation The haracterized ontrol Valve is operated by a rotary actuator. The actuators are controlled by a standard voltage for on/off control or a proportional signal or 3-point control system which move the ball of the valve to the position dictated by the control system. Product eatures The equal-percentage characteristic of the flow is ensured by the integral characterizing disc. This characteristic provides linear heating or cooling output from the coil improving energy efficiency and comfort. ctuator Specifications ontrol type On/Off, loating Point, -10 V, Multi-unction Technology (MT) Manual override R, GR, R and GKR series lectrical connection 3 ft [1m] cable with ½ conduit fi tting or covered screw terminal strip Valve Specifications Service low characteristic ction chilled or hot water, 60% glycol -port equal percentage max 90 rotation Sizes ½, 3, 4, 5:, 6 Type of end fi tting Materials ody all Stem Seats haracterizing disc Packing ody pressure rating Media temp range lose-off pressure Maximum differential pressure (ΔP) Leakage NSI 15 fl ange pattern cast iron (painted) stainless steel stainless steel PT stainless steel PM O-rings, lubricated ccording to NSI 15, standard class 0 to 50 [-18 to +10 ] 100 psi 50 psi 0% for to 15

16 TR4-3 ctuators, On-Off, loating Point imensions with -Way Valve.50 [63.5] 3.5 [8.6] [71.6] Models TR4-3-T US TR4-3 US TR4-3/300 US TR4-3/500 US TR4-3-T US with 3 ft plenum rated cable TR4-3-T US with 10 ft plenum rated cable TR4-3-T US with 16 ft plenum rated cable Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] 07()-11() ½ [61.1] 1.39 [35.] 1()-15() ½ [60.4] 1.78 [45.] 17()-1() ¾ 0.73 [69.3] 1.87 [47.4] Technical ata ontrol on/off, fl oating point Nominal voltage 4 V 50/60 Hz Nominal voltage range V Power consumption 1 W Transformer sizing 1V (class power source) lectrical connection screw terminals accessible after removal of small cover (3 ft, 10 ft, 16 ft cables optional) Input impedance 0.36 kω ngle of rotation 90 Position indication integrated into handle Manual override push down handle Running time hz, hz Humidity 5 to 95% non-condensing mbient temperature - to 1 (-30 to 50 ) Storage temperature -40 to 176 (-40 to 80 ) Housing NM 1/IP40 Housing rating UL94-5V() gency listing culus according to UL /--14, N/ S :0, according to 004/108/ and 006/95/ for line voltage and/or S versions Noise level max. 35 db () Quality standard ISO 9001 Rated impulse voltage 330V, ontrol pollution degree, Type of action 1 imensions with 3-Way Valve.50 [63.5].8 [71.6] 3.5 [8.6] Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] 307()-311() ½ [61.1] 1.39 [35.] 1.0 [30.6] 31()-315() ½ [60.4] 1.78 [45.] 1.9 [3.8] 317()-31() ¾ 0.73 [69.3] 1.87 [47.4] 1.47 [37.3]

17 TR4-3 ctuators, On-Off, loating Point Wiring iagrams NOT: TR4-3(-T) US cannot be wired in parallel with themselves or any other actuator. 3 The common connection from the actuator must be connected to the Hot connection of the controller. ctuators with plenum rated cable do not have numbers on wires; use color codes instead. 4 The actuator Hot must be connected to the control board Hot. WRNING Live lectrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. ailure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. loating ontrol W187 W186 On/Off ontrol You may not use one wire control. 17

18 TR4-SR ctuators, Proportional imensions with -Way Valve.50 [63.5] 3.5 [8.6] [71.6] Models TR4-SR-T US TR4-SR US TR4-SR/300 US TR4-SR/500 US TR4-SR-T US with 3 ft plenum rated cable TR4-SR-T US with 10 ft plenum rated cable TR4-SR-T US with 16 ft plenum rated cable Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] 07()-11() ½ [61.1] 1.39 [35.] 1()-15() ½ [60.4] 1.78 [45.] 17()-1() ¾ 0.73 [69.3] 1.87 [47.4] Technical ata ontrol proportional Nominal voltage 4 V 50/60 Hz, 4 V Nominal voltage range V, V Power consumption 0.5 W Transformer sizing 1V (class power source) lectrical connection screw terminals accessible after removal of small cover (3 ft, 10 ft, 16 ft cables optional) Input impedance 100 kω ngle of rotation 90 irection of rotation reversible with switch under cover Position indication integrated into handle Manual override push down handle Running time 90 seconds Humidity 5 to 95% non-condensing mbient temperature - to 1 (-30 to 50 ) Storage temperature -40 to 176 (-40 to 80 ) Housing NM 1/IP40 Housing rating UL94-5V() gency listing culus according to UL /--14, N/ S :0, according to 004/108/ and 006/95/ for line voltage and/or S versions Noise level max. 35 db () Quality standard ISO 9001 Rated impulse voltage 500V, ontrol pollution degree, Type of action 1 NOT: Response sensitivity is 75mV imensions with 3-Way Valve.50 [63.5].8 [71.6] 3.5 [8.6] Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] 307()-311() ½ [61.1] 1.39 [35.] 1.0 [30.6] 31()-315() ½ [60.4] 1.78 [45.] 1.9 [3.8] 317()-31() ¾ 0.73 [69.3] 1.87 [47.4] 1.47 [37.3]

19 TR4-SR ctuators, Proportional Wiring iagrams W190 ctuators with color coded wires are optional. Wire numbers are provided for reference. UTION quipment damage! ctuators may be connected in parallel. Power consumption and input impedance must be observed. 3 ctuators may also be powered by 4 V. WRNING Live lectrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. ailure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. to 10 V ontrol of TR4-SR(-T) US W191 4 to 0 m ontrol of TR4-SR(-T) US irect/reverse acting switch is under wiring cover. R = W with decrease in signal L = W with decrease in signal No feedback 19

20 LR ctuators, On/Off, loating Point imensions with -Way Valve 1351 H1 H Models LR4-3-T LRX4-3-T w/terminal lock LR4-3 LRX4-3 w/3 ft. cable LR4-3-S LRX4-3-S w/built-in ux. Switch Technical ata ontrol Power supply Power consumption Transformer sizing lectrical connection LR4-3 LRX4-3 Overload protection Input impedance ngle of rotation irection of rotation Position indication Manual override Running time LR4-3 LRX4-3 on/off, fl oating point 4 V ± 0% 50/60 Hz 4 V ± 10% running 1.5 W holding 0. W V (class power source) ½ conduit connector 18 G, plenum rated cable 3 ft [1m] 3 ft [1m], 10 ft [3m], 16 ft [5m] electronic throughout 0 to 95 rotation 600 Ω 90, adjustable with mechanical stop reversible with protected handle external push button 90 seconds, constant independent of load 150, 95, 60, 45, 35 seconds, constant independent of load Humidity 5 to 95% RH, non-condensing (N ) mbient temperature - to 1 [-30 to 50 ] Storage temperature -40 to 176 [-40 to 80 ] Housing type NM /IP54 Housing material UL94-5V gency listings culus according to UL /--14, N/ S :0, according to 004/108/ and 006/95/ for line voltage and/or S versions Noise level less than 35 d () Quality standard ISO 9001 LR T lectrical connection screw terminal (for 6 to 14 G wire) protected (NM, IP0) Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] 07()-11() ½ [35.] 1.39 [35.] 1()-15() ½ [45.] 1.78 [45.] 17()-1() ¾ [47.4] 1.87 [47.4] [47.4] 1.87 [47.4] ¼ [47.4] 1.87 [47.4] imensions with 3-Way Valve H1 H Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] 307()-311() ½ [5.] 1.39 [35.] 1.0 [30.6] 31()-315() ½ [60.4] 1.78 [45.] 1.9 [3.8] 317()-31() ¾ 0.73 [69.3] 1.87 [47.4] 1.47 [37.3] [78.4] 1.87 [47.4] 1.59 [40.3] 135 LR S uxiliary switch 1 SPT, 3 50 V, UL Listed, adjustable 0 to 100 Rated impulse voltage 800V, ontrol pollution degree 3, Type of action 1 (1. for -S models) 0

21 LR ctuators, On/Off, loating Point Wiring iagrams 3 UTION quipment damage! ctuators may be connected in parallel. Power consumption and input impedance must be observed. ctuators are provided with color coded wires. Wire numbers are provided for reference. 4 ctuators may also be powered by 4 V. Meets culus or UL and S requirements without the need of an electrical ground connection. WRNING Live lectrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. ailure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off control W193-LR-08 W13-LR-08 loating Point or On/Off control uxiliary switch 1

22 LR...4-SR ctuators, Proportional imensions with -Way Valve 1351 H1 H Models LR4-SR-T LRX4-SR-T w/terminal lock LR4-SR LRX4-SR w/3ft. cable Technical ata Power supply 4 V ± 0% 50/60 Hz 4 V ± 10% Power consumption running 1.5 W holding 0.4 W Transformer sizing 3 V (class power source) lectrical connection ½ conduit connector 18 G, plenum rated cable LR4-SR LRX4-SR 3 ft [1m] 3 ft [1m], 10 ft [3m], 16 ft [5m] Overload protection electronic throughout 0 to 95 rotation Operating range Y to 10 V, 4 to 0 m eedback output U 1 to 10 V, max 0.5 m Input impedance 100 kω (0.1 m), 500 Ω ngle of rotation 90, adjustable with mechanical stop irection of rotation reversible with protected Position indication handle Manual override external push button Running time LR4-SR LRX4-SR constant independent of load 90 seconds 150, 95, 60, 45, 35 seconds Humidity 5 to 95% RH non-condensing (N ) mbient temperature - to 1 [-30 to 50 ] Storage temperature -40 to 176 [-40 to 80 ] Housing NM /IP54 Housing material UL94-5V gency listings culus according to UL /--14, N/S :0, according to 004/108/ and 006/95/ for line voltage and/or S versions Noise level <35 d() Quality standard ISO 9001 LR...4-SR-T lectrical connection screw terminal (for 6 to 14 G wire) protected (NM /IP0) Rated impulse voltage 800V, ontrol pollution degree 3, Type of action 1 (1. for -S models) Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] 07()-11() ½ [61.1] 1.39 [35.] 1()-15() ½ [60.4] 1.78 [45.] 17()-1() ¾ 0.73 [69.3] 1.87 [47.4] [78.4] 1.87 [47.4] ¼ [94.6] 1.87 [47.4] imensions with 3-Way Valve H1 H Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] 307()-311() ½ [5.] 1.39 [35.] 1.0 [30.6] 31()-315() ½ [60.4] 1.78 [45.] 1.9 [3.8] 317()-31() ¾ 0.73 [69.3] 1.87 [47.4] 1.47 [37.3] [78.4] 1.87 [47.4] 1.59 [40.3] 135

23 LR...4-SR ctuators, Proportional Wiring iagrams UTION quipment damage! ctuators may be connected in parallel. Power consumption and input impedance must be observed. 3 ctuators may also be powered by 4 V. W65-LR-08 5 Only connect common to neg. ( ) leg of control circuits. to 10 V control Meets culus or UL and S requirements without the need of an electrical ground connection. The ZG-R Ω resistor converts the 4 to 0 m control signal to to 10 V, up to actuators may be connected in parallel. W65-LR-08 WRNING Live lectrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. ailure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 4 to 0 m control 3

24 LR ctuators, On/Off, loating Point imensions with -Way Valve 1353 H1 H Models LR10-3 LRX10-3 Technical ata ontrol Power supply Power consumption Transformer sizing lectrical connection LR10-3 LRX10-3 Overload protection Input impedance ngle of rotation irection of rotation Position indication Manual override Running time LR10-3 LRX10-3 Humidity mbient temperature Storage temperature Housing Housing material gency listings On/Off, loating Point 100 to 40 V, 50/60 Hz (nominal) 85 to 65 V, 50/60 Hz (tolerance) running W holding 0.5 W 4 V (class power source) ½ conduit connector 18 G, plenum rated cable 3 ft [1m] 3 ft [1m], 10 ft [3m], 16 ft [5m] electronic throughout 0 to 95 rotation 600 Ω 90, adjustable with mechanical stop reversible with protected handle external push button 90 seconds, constant independent of load 150, 95, 60, 45, 35 seconds, constant independent of load 5 to 95% RH non-condensing (N ) - to 1 [-30 to 50 ] -40 to 176 [-40 to 80 ] NM /IP54 UL94-5V culus according to UL /--14, N/S :0, according to 004/108/ and 006/95/ for line voltage and/or S versions <35 d() Noise level Quality standard ISO 9001 Rated impulse voltage 4kV, ontrol pollution degree 3, Type of action 1 Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] 07()-11() ½ [61.1] 1.39 [35.] 1()-15() ½ [60.4] 1.78 [45.] 17()-1() ¾ 0.73 [69.3] 1.87 [47.4] [78.4] 1.87 [47.4] ¼ [94.6] 1.87 [47.4] imensions with 3-Way Valve H1 H Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] 307()-311() ½ [5.] 1.39 [35.] 1.0 [30.6] 31()-315() ½ [60.4] 1.78 [45.] 1.9 [3.8] 317()-31() ¾ 0.73 [69.3] 1.87 [47.4] 1.47 [37.3] [78.4] 1.87 [47.4] 1.59 [40.3]

25 LR ctuators, On/Off, loating Point Wiring iagrams W405 UTION quipment damage! ctuators may be connected in parallel. Power consumption and input impedance must be observed. Meets culus or UL and S requirements without the need of an electrical ground connection. WRNING Live lectrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. ailure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off W406 loating Point or On/Off control 5

26 LR...10-SR ctuators, Proportional imensions with -Way Valve 1353 H1 H Models LR10-SR LRX10-SR Technical ata Power supply Power consumption Transformer sizing lectrical connection LR10-SR LRX10-SR Overload protection Operating range Y eedback output U Input impedance ngle of rotation irection of rotation Position indication Manual override Running time LR10-SR LRX10-SR Humidity mbient temperature Storage temperature Housing Housing material gency listings 100 to 40 V, 50/60 Hz (nominal) 85 to 65 V, 50/60 Hz (tolerance) running.5 W holding 1 W 4.5 V (class power source) ½ conduit connector 18 G, plenum rated cable 3 ft [1m] 3 ft [1m], 10 ft [3m], 16 ft [5m] electronic throughout 0 to 95 rotation to 10 V, 4 to 0 m 1 to 10 V, max 0.5 m 100 kω (0.1 m), 500 Ω 90, adjustable with mechanical stop reversible with protected handle external push button constant independent of load 90 seconds 150, 95, 60, 45, 35 seconds 5 to 95% RH non-condensing (N ) - to 1 [-30 to 50 ] -40 to 176 [-40 to 80 ] NM /IP54 UL94-5V culus according to UL /--14, N/S :0, according to 004/108/ and 006/95/ for line voltage and/or S versions <35 d() Noise level Quality standard ISO 9001 Rated impulse voltage 4kV, ontrol pollution degree 3, Type of action 1 Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] 07()-11() ½ [61.1] 1.39 [35.] 1()-15() ½ [60.4] 1.78 [45.] 17()-1() ¾ 0.73 [69.3] 1.87 [47.4] [78.4] 1.87 [47.4] ¼ [94.6] 1.87 [47.4] imensions with 3-Way Valve H1 H Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] 307()-311() ½ [61.1] 1.39 [35.] 1.0 [30.6] 31()-315() ½ [60.4] 1.78 [45.] 1.9 [3.8] 317()-31() ¾ 0.73 [69.3] 1.87 [47.4] 1.47 [37.3] [78.4] 1.87 [47.4] 1.59 [40.3]

27 LR...10-SR ctuators, Proportional Wiring iagrams 100 to 40 V W365 UTION quipment damage! ctuators may be connected in parallel. Power consumption and input impedance must be observed. 6 Only connect common to neg. ( ) leg of control circuits Ω resistor converts the 4 to 0 m control signal to to 10 V. 15 LR(X) can be supplied with both 10 V and 30 V. 19 ll 10 V and 30 V actuators use appliance rated cables. N L1 H L 1 Neutral Hot ommon Hot ( ) ontrol Signal V/m (+) to 10 V ( ) eedback Signal (+) 3 Y Input, to 10V 5 U Output, to 10V 1 0 able Meets culus or UL and S requirements without the need of an electrical ground connection. WRNING Live lectrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. ailure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. able 1 LR...10-SR Proportional, 100 to 40V 7

28 LR...4-MT ctuators, Multi-unction Technology imensions with -Way Valve 1353 H1 H Models LRX4-MT Technical ata Power supply Power consumption Transformer sizing lectrical connection LRX4-MT Overload protection Operating range Y eedback output U Input impedance ngle of rotation irection of rotation Position indication Manual override Running time Humidity mbient temperature Storage temperature Housing Housing material gency listings lexible Version 4 V ± 0% 50/60 Hz 4 V ± 10% running W holding 1. W 6 V (class power source) ½ conduit connector 18 G, plenum rated cable 3 ft [1m], 10 ft [3m], 16 ft [5m] electronic throughout 0 to 95 rotation to 10 V (default) 4 to 0 m variable (V, PWM, fl oating point, on/off) to 10 V, 0.5m max V variable 100 kω (0.1 m), 500 Ω 1500 Ω (PWM, fl oating point, on/off) 90 electronically variable adjustable with mechanical stop reversible with protected handle external push button 150 seconds (default) Variable (35 to 150 secs) 5 to 95% RH non-condensing (N ) - to 1 [-30 to 50 ] -40 to 176 [-40 to 80 ] NM /IP54 UL94-5V culus according to UL /--14, N/S :0, according to 004/108/ and 006/95/ for line voltage and/or S versions <35 d() Noise level Quality standard ISO 9001 Rated impulse voltage 800V, ontrol pollution degree 3, Type of action 1 (1. for -S models) Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] ½ [61.1] 1.39 [35.] 1-15 ½ [60.4] 1.78 [45.] 17-1 ¾ 0.73 [69.3] 1.87 [47.4] [78.4] 1.87 [47.4] ¼ [94.6] 1.87 [47.4] imensions with 3-Way Valve H1 H Valve Nominal Size imensions (Inches [mm]) Valve ody Inches N [mm] ½ [61.1] 1.39 [35.] 1.0 [30.6] ½ [60.4] 1.78 [45.] 1.9 [3.8] ¾ 0.73 [69.3] 1.87 [47.4] 1.47 [37.3] [78.4] 1.87 [47.4] 1.59 [40.3]

29 LR...4-MT ctuators, Multi-unction Technology Wiring iagrams W538 UTION quipment damage! ctuators may be connected in parallel. Power consumption and input impedance must be observed. 3 ctuators may also be powered by 4 V Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. ontrol signal may be pulsed from either the Hot (source) or the ommon (sink) 4 V line. ontact closures & also can be triacs. & should both be closed for triac source and open for triac sink. or triac sink the common connection from the actuator must be connected to the hot connection. On/Off control W538 The ZG-R Ω resistor converts the 4 to 0 m control signal to to 10 V, up to actuators may be connected in parallel. WRNING Live lectrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. ailure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. loating Point W538 V/4-0 m W538 PWM 9

Pressure Independent Characterized Control Valves (PICCV)

Pressure Independent Characterized Control Valves (PICCV) Pressure Independent haracterized ontrol s (PIV) Easy direct coupling of actuator with a single screw. Perpendicular mounting ISO flange and square drive head eliminate lateral forces on the stem. Vent

More information

VG2000 Series Cast Iron Flanged Globe Valves

VG2000 Series Cast Iron Flanged Globe Valves VG2000 Series ast Iron Flanged Globe Valves Installation Instructions Part No. 14-1161-106, Rev. Issued November 15, 2013 Supersedes June 15, 2007 pplications VG2000 Series ast Iron Flanged Globe Valves

More information

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data

More information

Products no longer available

Products no longer available Technical ata sheet R6..R haracterize control valves, 2-way, with flange PN 6 for open an close col an warm water systems for moulating control on the water sie of air-hanling an heating systems air bubble-tight

More information

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing Technical data sheet R5.. Characterized control valves, 3-way, with external thread for open and closed cold and warm water systems for modulating control on the water side of air-handling and heating

More information

Float and Thermostatic Traps Series H, C and X

Float and Thermostatic Traps Series H, C and X Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Type overview. Technical data

Type overview. Technical data Technical data sheet R3..xx-S.. Characterised control valve, 3-way, Internal thread For closed cold and warm water systems For modulating water-side control of air handling units and heating systems ir

More information

Frequently Asked Questions

Frequently Asked Questions Frequently Asked Questions System and Valve Basics: 1. Q: What is good cooling coil performance? A: The temperature range is controlled within +/- 0.5 F (0.28 C) off the cooling coil at set point or below.

More information

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit) 000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,

More information

Overview of types. Technical data

Overview of types. Technical data Technical data sheet R3..xx-S.. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems For modulating water-side control of HU and heating systems ir bubble-tight

More information

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal

More information

2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection. www.usa.siemens.

2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection. www.usa.siemens. 2012 Valve & Valve Actuator Catalog For new construction or retrofits, simplify projects with our complete selection. www.usa.siemens.com/hvac Our dynamic duos provide comprehensive control. Fast installation

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

TAC Erie VT/VS PopTop Series Two Position Spring Return Valves

TAC Erie VT/VS PopTop Series Two Position Spring Return Valves TC 1354 Clifford venue P. O. ox 2940 Loves Park, IL 61132-2940 www.tac.com TC Erie VT/VS PopTop Series Two Position Spring Return Valves General & High Close-Off PopTop Zone Valves General Instructions

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

650W Single Output Power Supply

650W Single Output Power Supply AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent

More information

QLM and QLD Series Three-port Control Valves

QLM and QLD Series Three-port Control Valves Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS. Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

Limit Switches/ Receptacle Assembly... For Nuclear Environments

Limit Switches/ Receptacle Assembly... For Nuclear Environments 180-302/402 Series Inside ontainment reas TM Limit Switches/ Receptacle ssembly... or Nuclear nvironments eatures: Qualified to I s 344-1975, 323-1974, and 382-1972. Manufactured to a quality assurance

More information

Series IDU/IDF. Refrigerated Air Dryer

Series IDU/IDF. Refrigerated Air Dryer Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

DOUBLE SEAT BRONZE BODY HIGH CAPACITY

DOUBLE SEAT BRONZE BODY HIGH CAPACITY PS593DB HEAVY DUTY BRONZE GLOBE CONTROL VALVES DB DOUBLE SEAT BRONZE BODY HIGH CAPACITY 1, 1-1/4, 1-1/2, and 2 Union Ends ANSI Class 250 Body Rating ANSI Class II Close off Bronze or Stainless Steel Trim

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Valve and Valve Actuator Selection Guide

Valve and Valve Actuator Selection Guide www.sbt.siemens.com/hvp/components Building Technologies Building Technologies Siemens Building Technologies, Inc. 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 USA Tel 847 215 1000 Siemens Building

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Why and How we Use Capacity Control

Why and How we Use Capacity Control Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,

More information

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions

More information

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification... OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

LSB Series. Valve Position Monitor. www.powergenex.com. All innovation on driving your valve automation

LSB Series. Valve Position Monitor. www.powergenex.com. All innovation on driving your valve automation LS Series Valve Position Monitor ll innovation on driving your valve automation www.powergenex.com LS-1000 Series Valve Position Monitor Robust valve position monitor with a good recognizable beacon, various

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable

More information

COUNTERBALANCE VALVES

COUNTERBALANCE VALVES COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

G670 Intermittent Pilot Ignition Controls

G670 Intermittent Pilot Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

BITMAIN. APW3-12-1600 PSU Series User Guide

BITMAIN. APW3-12-1600 PSU Series User Guide BITMAIN APW3-12-1600 PSU Series User Guide Contents 1 Overview... 3 2 Features... 3 3 Specifications... 4 4 Switching On/Off Remotely... 5 5 Order Information & Wire Type... 6 5.1 Order Information...

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51 34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in

More information

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB Compact automatic flow rate regulator with polymer cartridge 127 series REGISTERED BS EN ISO 9001:2000 Cert. n FM 21654 UNI EN ISO 9001:2000 Cert. n 0003 CALEFFI 01166/09 GB Function The AUTOFLOW devices

More information

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good. TA-FUS1ON Fully adjustable Kvs control and balancing valves. That s just two good. Supported by the Reece hvac-r network. Through our 36 stores around Australia, Reece hvac-r is committed to supporting

More information

Richter Twin Piston Quarter-turn Actuators

Richter Twin Piston Quarter-turn Actuators Richter Twin Piston Quarter-turn ctuators R ompact Powerful Maintenance-free R ouble-acting quarter-turn actuators The actuators are the optimum automation units in technical and commercial terms for Richter

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features Pressure Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure Reducing Valve is a hydraulically operated,

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D-193. www.usa.siemens.com/hvac

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D-193. www.usa.siemens.com/hvac Introduction Angle/Flared/Sequence/Changeover Service D-193 In this section, you will find flared, angled, sequence and changeover valves for use in service applications. D-194 Need additional assistance?

More information

REGULATORS 175/153 Series

REGULATORS 175/153 Series 175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed

More information

Data sheet ECC 12 and 22

Data sheet ECC 12 and 22 Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe

More information

Know-how makes the difference. Electrical Actuators

Know-how makes the difference. Electrical Actuators Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product

More information

AURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM

AURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM UROR 1030 ND 1040 Series SUCTION DIFFUSERS, COMINTION ND TRIPLE DUTY VLVES WWW.URORPUMP.COM UROR 1030 ND 1040 Series Suction Diffusers, Combination and Triple Duty Valves Designed for Direct Mounting on

More information

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle

More information

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves 1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire

More information

The quadrature signals and the index pulse are accessed through five 0.025 inch square pins located on 0.1 inch centers.

The quadrature signals and the index pulse are accessed through five 0.025 inch square pins located on 0.1 inch centers. Quick Assembly Two and Three Channel Optical Encoders Technical Data HEDM-550x/560x HEDS-550x/554x HEDS-560x/564x Features Two Channel Quadrature Output with Optional Index Pulse Quick and Easy Assembly

More information

167D Series Switching Valves

167D Series Switching Valves June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are

More information

VU53S; VU54S; VU443A; VU444A; VU843A; VU844A Fan Coil Valves and Actuators

VU53S; VU54S; VU443A; VU444A; VU843A; VU844A Fan Coil Valves and Actuators VU53S; VU54S; VU443A; VU444A; VU843A; VU844A Fan Coil Valves and Actuators APPLICATION VU Fan Coil Actuator and Valves The VU443, VU444, VU843 and VU844 Fan Coil Valve Actuators are used in conjunction

More information

Specification Data CM37002 09/10. Putting You In Control. 37002 Series MiniTork ll Control Valves. Heavy Duty Control Butterfly Valves

Specification Data CM37002 09/10. Putting You In Control. 37002 Series MiniTork ll Control Valves. Heavy Duty Control Butterfly Valves Putting You In Control Specification ata CM37002 09/10 37002 Series MiniTork ll Control Valves Heavy uty Control Butterfly Valves resser Masoneilan 37002 Series MiniTork II Control Valves Heavy uty Control

More information

Self-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F

Self-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F Self-operated Temperature Regulators Type 1 to Type 9 PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F Edition April 2012 Information Sheet T 2010 EN Self-operated

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

APCO SLOW CLOSING AIR/VACUUM VALVES

APCO SLOW CLOSING AIR/VACUUM VALVES BULLETIN 1 JULY 01 APCO SLOW CLOSING AIR/VACUUM VALVES Series 1900 APCO Slow Closing Air/Vacuum s Maximum Air Flow Velocity in Good Pipeline Design The Air/Vacuum operates in the normal fashion allowing

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4 SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended

More information

Check Valves & Actuated Valves

Check Valves & Actuated Valves heck Valves & ctuated Valves & U Series Piston non-return valves rated 6,000 psi & 10,000 psi X Series Piston non-return valves rated 20,000 psi Pneumatic ctuators Pneumatically actuated valves Electric

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

AMX300 DirectConnect Mixing Valve Kits

AMX300 DirectConnect Mixing Valve Kits AMX300 DirectConnect Mixing Valve Kits INSTALLATION INSTRUCTIONS Tools needed (not supplied) 1. Wrench 2. Pliers Safety Definitions These safety terms identify information you must read. CAUTION Indicates

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...

More information

Talon and Talon SR User Manual

Talon and Talon SR User Manual Talon and Talon SR User Manual Brushed DC motor controller Version 1.3 Cross the Road Electronics, LLC www.crosstheroadelectronics.com Cross The Road Electronics, LLC Page 1 4/2/2013 Device Overview Clear,

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR 3 Phase Air Conditioner Component R2A3**GHR DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER

More information

Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves

Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves CRANE Energy Flow Solutions TM Donald H. Johnson Crane Energy Flow Solutions 1 Crane Co. Resolution Made By Richard Teller

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009

Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009 Applying Pressure Independent Control Valves in H.V.A.C. Systems A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009 1 Introduction I know, as building design consultants, so much of your effort

More information