Industrial-Commercial Surge Protection

Size: px
Start display at page:

Download "Industrial-Commercial Surge Protection"

Transcription

1 Industrial-Commercial Surge Protection Your One Source for all Surge Protection Devices Panel Mount Surge Protect 1-4, Surge Amp Capacity VorCap Surge Protection Modules The Next Generation Of Surge Suppression systems Panel mount devices can be installed directly on the main electrical panel or equipment disconnect. Devices range from 1, to 4, surge amp capacity and are available in 4, 7 and 1 mode configuration. A variety of enclosures and diagnostic options are available. The ultimate in Surge Protection technology. Fail Safe design insures maximum protection in high surge probability locations. Even under catastrophic surge conditions VorCap technology will take your equipment off line before a surge will, Available in a modular assembly or can be installed as a point source device. Modular Surge Protection Panels Pop Out Field Replaceable Modules Point of Use Surge Devices Equipment level Surge Protection Devices From 1, to 6, Surge Amp Capacity Replacable Modules Virtulally Eliminate Down Time Five, Seven and Ten Mode configurations available with internal & external 2 Kaic fused disconnects, red/green diagnostic LED s, audible alarm, digital surge counter, NEMA 4 & NEMA 4X Stainless steel enclosures. All units come standard with pop out replaceable modules by mode. Equipment level protection for AC / DC Network Cable, Data and low voltage applications. Available in Din-Rail and direct inline installation. Modules can be mounted directly into equipment cabinets or can be custom configured in a variety of enclosures. PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

2 About PSP Products Inc Phoenix Drive Manassas, VA PSP Products Inc. Has served the industrial, commercial, utility and residential markets by providing superior surge protection products and services for nearly twenty years. From our humble beginnings in the office products industry we ve evolved into a forward thinking company offering innovative products to meet the demand of an ever changing market. We strongly believe that our customer is our most valuable asset. Unlike many of our larger competitors, we believe we work for our customers and conform to meet their needs not ours. We stand ready to assist in any way possible to support our customers with any challenge or urgent requirement they may encounter. PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

3 Surge Devices Typhoon 2 Series Nipple Mount- 16, Amps per phase 12/24 Volt single phase whole house surge protector NEMA 4 enclosure, type 1 2 Ka in with LED diagnostics. Typhoon 3 Nipple Mount 1, & 2, Amps per phase, NEMA 4 enclosure, 65 & 2 kaic, with LED s each phase, 7 Mode Protection, Dry Contacts, 1 year warranty. Also available in a NEMA 4X enclosure with Internal/External Fused Disconnect and surge counter. Typhoon 4 3, Amps per phase, NEMA 4 enclosure, 2 kaic, LED s each phase, 1 Mode Protection, Dry Contacts, Push To Test Diagnostics, Surge Counter, Fused Disconnect, 2 year Warranty. Also available in a NEMA 4X enclosure with Internal/External Fused Disconnect and surge counter. Typhoon 5 3,, 4, & 6, Amps per phase, NEMA 4 enclosure, 2 kaic, LED s each phase, Dry Contacts, Audible Alarm, Vorcap Modules, 3 year warranty. OPTIONS: Fused Disconnect, Stainless Steel, 4X enclosure. Vorcap Modules- 1, 2 & 3K surge capacity. Available as individual models, pre-assembled bar assemblies and din-rail. The ultimate surge protection device, trusted by the oil and telecom industries to protect their most critical equipment in the most vulnerable locations. AC Din rail Mount Products 4-15, surge amp capacity modules can be combined and configured for most any requirement. Small foot print allows for internal mounting. Modules include visual end of life indicators as well as for C dry contacts for remote monitoring. Hurricane 3 1,, 2, & 3, Amps per phase, NEMA 4 enclosure, 2 kaic, LED s each phase. Audible Alarm, Dry Contacts, 1 year warranty. OPTIONS: Flush Mount, Surge Counter, Fused Disconnect, Stainless Steel & NEMA 4X. Modular Hurricane 5 1, to 6, Amps per phase, Replaceable modules by mode. Available in NEMA 1, 4, 4X, stainless with full diagnostics including, red-green led s with push to test, dry contacts, audible alarm with Disable Switch, Surge Counter, internal and external fused disconnect. DC Din rail Products 4-7, surge amp capacity modules can be combined and configured for most any requirement. Small foot print allows for internal mounting. Modules include visual end of life indicators as well as for C dry contacts for remote monitoring. Ethernet- Cat 5 & POE Products - 4, surge amp capacity plug and play either net protection. POE or standard configuration available for a broad range of surge protection applications. Generator Surge Protector - 16, surge amp capacity type one surge protector designed and approved to be installed on the LINE side of the generator transfer switch protecting both the transfer switch and the entire home from damaging electrical surges. 2 Ka In, NEMA 4 Enclosure.

4 TYPHOON 2 R e s i d e n t i a l S u rg e P ro t e c t i o n TYPHOON SERIES 12/24 SPLIT PHASE WHOLE HOUSE SURGE PROTECTOR Type 1 Device - No Breaker Required For Installation Feat ures UL rd Edition Listed Common mode suppression Thermal fused metal oxide varistor (MOV) suppression technology Light-emitting diode (LED) visual protection status indicator Type 4-outdoor-rated Enclosures Available in maximum surge current capacity of 16kA Bene fits Surge protection devices with extended operating temperature and the versatility of either a Type 1 indoor or Type 4 outdoor rated enclosure. Basic Applications Residential Telecommunications Light commercial applications PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

5 TYPHOON 2 R e s i d e n t i a l S u rg e P ro t e c t i o n T1B16-4X-NF Specifications Electrical Model Surge Protection Device (SPD) Type to UL Operating AC Voltage Maximum Continuous Operating AC Voltage (MCOV): Line-Neutral Nominal Discharge Current [I n ] Line-Ground Neutral-Ground Line-Line Maximum Surge Current Capacity [I ]: Line-Neutral max Fault Current Rating (Sccr) Voltage Protection Rating (VPR): Suppression Technology Mechanical Line-Ground Neutral-Ground Line-Line Line-Neutral Line-Ground Neutral-Ground Connection Terminal (Suppression) Hardwired Operation Temperature ( C) Enclosure Type (Outdoor) Enclosure Dimension (L W H) Weight Line-Line T1B16-4X-NF Type 1 12/24 V 3W+G 14 V 14 V 14 V 28 V 2 ka 8 ka 8 ka 8 ka 1 ka 1kA No Breaker 2ka With Breaker 6 V 1V 6 V 1V MOV #12 AWG pigtail leads -4 C to +8 C Type 4 PVC Plastic [ mm] 4. lbs [1.81 kg] Pr oduc t Diagram [294.14] [62.31] 2.45 [11.6] 4. [8. [32.46] [5.8] [8. [5.8] 2. [13.43] [11.6 [117.73] [mm] inches Optional Flush Mount Cover AWG=American Wire Gauge PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

6 H1-75-4N 12/24 Single Phase Type 1 75Ka Surge Protector H1-75-4N All Mode Type 1 Surge Protection With MOV and Dual Gas Tube Technology H1-75-4N Single Phase Surge Protector Features Small Footprint, Nipple or Bracket Installation 75Ka Imax Surge Capacity Structure All Mode Surge Protector with Gas Tube Technology U.L rd Addition In 1Ka Type 1 Type 4X Indoor/Outdoor Enclosure Internal Thermal fused (MOV) suppression technology Light-emitting diode (LED) visual indicator Ten Year Warranty Available in 12, 277 and 48 Volts AC Green: Black Black locknut Optional Bracket Enclosure PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

7 H1-75-4N 12/24 Single Phase 75 Ka Surge Protector Specifications Surge Protection Device UL Type: Voltage range: Maximum Continuous Voltage (MCOV) Nominal Discharge Current (In) Maximum Surge Capacity (Imax) Voltage Protection Rating (VPR) Suppression Technology Operating Temperature Enclosure Type: Connection Terminals: Standards: Warranty: Type 1 12/24 Single Phase 15 Line Ground 3 Line-Line 1 Ka 75 Ka 6 Volts L-G Thermally Protected MOV with Dual Gas Tubes -4 C - +8 C NEMA 4X Indoor Outdoor Hardwire12 14 AWG Pigtail Leads UL rd Edition IEEE IP65 1 Year Warranty G F H C D E I K J A B L A B C D E F G H I J K L PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

8 TYPHOON 3 Co m m erc i a l Gra d e S u rg e P ro t e c t i o n T1AC1/T1AC2 & T2AC1/T2AC2 Series Up to T1AC21SM Series Optional Flush Mount Plate Available Up to PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

9 TYPHOON 3 Co m m erc i a l Gra d e S u rg e P ro t e c t i o n T1AC1/T1AC2 & T2AC1/T2AC2 Series T1AC21SM TOAC2A-4-N* TOAC2-4-N 2 Kaic T1AC1A-4-N* T1AC1-4-N 2 Kaic T2AC1A-4-N* T2AC1-4-N 2 Kaic T1AC2A-4-N* T1AC2-4-N 2 Kaic T2AC2A-4-N* T2AC2-4-N 2 Kaic T1AC21SM2A-4-N* 2 Kaic * Denotes model numbers with form C N/O N/C Dry Contacts PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

10 TYPHOON 4 Co m m erc i a l Gra d e S u rg e P ro t e c t i o n O V E R V I E W : The PSP Vortexx AMV Series features All-Mode AC surge F E AT UR E S suppression solutions with sine wave tracking circuitry for EMI/ RFI filtering. Available in a variety of service voltage configurations, the AMV Series is the ideal choice when applications require all-mode suppression and filtering capabilities. True 1 Mode Device on 3 phase products. The AMV Series utilizes metal oxide varistors (MOVs) to protect your sensitive electronic equipment from the devastating effects of transient voltage surges. Each phase includes an LED status indicator to show protection status. LED on indicates suppressor is functional. LED off indicates suppressor or AC power failure. Form C contacts are standard. UL rd Edition September 29, 29 UL1283 listed Form C Relay contacts included Push-to-test diagnostics EMI/ RFI filtering sine wave tracking circuitry Individual thermal fusing and MOV components Fused disconnect option Sine Wave Tracking Circuitry T1AM4-4-N* T1EAM4-4-N* 8535 Phoenix Drive, Manassas VA 211 PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

11 TYPHOON 4 C o m m erc i a l Gra d e S u rg e P ro t e c t i o n T1AM4-4-N* T1EAM4-4-N* T2AM4-4-N* T2EAM4-4-N* T3AM4-4-N* T5AM4-4-N* T4AM4-3WG-4-N* 1 3, Amps/Phase PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

12 TYPHOON 5 Co m m erc i a l Gra d e S u rg e P ro t e c t i o n The Next Generation Of Surge Suppression systems O V E R V I E W : The Vortexx-Cap surge suppression module is used either as a stand alone protection element integrated inside larger systems or within PSP Transient Voltage Surge Suppressor Systems. It incorporates a single, heavy duty, distribution grade Metal Oxide Varistor (MOV) disk, assembled under pressure in an environmentally sealed aluminum casing. Vortexx-Cap s unique design provides very low internal contact resistance, excellent thermal management of the MOV and uniform distribution of the surge current over the total area of the protection element, thus resulting in an extremely high energy handling capability combined with very low let-through voltages. Vortexx-Cap s patented design minimizes the effects of aging and completely eliminates the risk of catastrophic failure, explosion or fire, which are common in conventional surge protection devices. Vortexx-Cap incorporates state-of-the-art MOV.technology developments providing superior protection characteristics, which remain unchanged throughout its long service life. The module has been designed in order to withstand repeated surges providing a cost effective and maintenance free operation in harsh environments. Independent test data confirms that a 4mm Vortexx-Caps module can withstand 1 ka strikes with % change in clamping voltage. The 8mm Vortexx module can withstand strikes up to 2 ka safeguarding critical electronic infrastructure against any potential threat. Vortexx-Cap is the only UL rd edition, recognized surge protection module in the industry rated for safe operation without the use of additional internal fuses. This unique feature combined with its capability to be directly connected to the power lines or bus bars (in-line connection), makes it the most reliable surge protection device known and insures that critical electronic equipment will remain protected at all times. PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

13 TYPHOON 5 Co m m erc i a l Gra d e S u rg e P ro t e c t i o n MODEL (SERIES) T-1 T-2 T-3 T-4 T-5 T-6 T-7 T-8 T-9 Nominal Line Voltage 12/24 12/28 24/12 277/48 48D 347/6 6D 22/38 24D MCOV 15V 15V 3/15V 35V 6V 48V 75V 25V 25V Voltage Protection Rating (VPR) Per UL1449, 3rd Ed. 6V 6V 9/6V 12V 18V 15V 2V 9V 9V Let Through Voltage Level for Surge Current 1kA (8/2) (IEEE C ) 45V 45V 8 / 45V 93V 165V 126 / 21V 21V 8 / 126V 8V Operating Frequency Operating Temperature EMI/RFI Noise Rejection Fault Current Tested to 5 Hz -4 TO +185 F (-4 TO +85C) Up to -5dB all Models 1KA / 2 ka Duration Performance 1kA square waveform 2msec (IEEE C62.11) 25hits 5A square waveform 2msec (IEEE C62.11) 25hits Audible Alarm Remote Signaling Response Time Product Max. Surge Current/Phase Enclosure Rating Surge Counter Connection Weight Diagnostics Yes Form C Dry Contacts < 1 Nano Seconds LifeTime-Warranty 3 Models 3, Amps/Phase 4, Amps/Phase 6, Amps/Phase NEMA 4 - IP65 Yes Terminals #6-#4/ AWG 3,Amps/Phase = 5 lbs. 4,Amps/Phase = 6 lbs. 6,Amps/Phase = 7 lbs. Red and Green LED s, Push to test buttons, Dry Contacts Audible Alarm and Alarm Silence Button. 8 MM Modules with optional external disconnect OPTIONS Safety Features Optional Housings Fused Safety Disconnect Stainless Steel Housing / 4X HousingAvailable 4 MM Module Internal rail mount Assembly PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

14 C o m m e r c i a l G r a d e S u r g e P r o t e c t i o n NEMA4 Nipple Mount Flush/Surface Mount NEMA4X Hard-Wired with Fused Disconnect & Surge Counter O V E R V I E W : The Hurricane 3 Series Surge Suppression device is the culmination of years of technological research and innovation. The Hurricane 3 provides state of the art protection in 1, 2 and 3 ka/phase configurations. Adaptable to many different voltages and Delta and WYE configurations, the Hurricane 3 is suitable for almost any TVSS need or environment. The Hurricane 3 provides protection in all modes, L-N, L-G, N-G AND L-L plus noise filtration up to -5dB. Its robust yet compact Nema 4 metal enclosure is suitable for both indoor and outdoor installations. Utilizing high-energy MOVs and EMI/RFI filtering, the Hurricane 3 will protect against transients originating from induced lightning strikes, utility switching or internal motor operation. The Hurricane 3 s internal SCCR (Short Circuit Current Rating) of 2 ka makes it capable of being installed in both Service and Branch panel applications without the need for cumbersome inline fusing. F E AT U R E S : UL1449 3rd Edition listed cul listed Multiple International Listings 4 Levels of Protection LED Status Indicators Audible Alarm NO/NC Dry Contacts NEMA 4 - (Nipple Product) NEMA 4X (option) Noise Filtration Sine Wave Tracking Circuitry 2 kaic Fault Current Rated Surge Counter (option) Integral Fused Disconnect (option) 1-Year Warranty PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

15 HURRICANE 3 Co m m erc i a l Gra d e MODEL (SERIES) H1C H2C H3C H4C H5C H6C H7C H8C H9C Nominal Line Voltage 12/24 12/28 24/12 277/48 48D 347/6 6D 22/38 24D MCOV 15V 15V 3/15V 35V 6V 48V 75V 25V 25V Voltage Protection Rating (VPR) Per UL1449, 3rd Ed. 6V/9V 6V 9V/6V 12V 18V 15V 2V 9V LetThrough Voltage Level for Surge Current 1kA (8/2) (IEEE C ) 45V 45V 8/45V 93V 165V 126V 21V 8V 8V Operating Frequency Operating Temperature EMI/RFI Noise Rejection Fault Current Fusing Pulse Life SINE Wave Tracking UL 1283 Protection Modes Audible Alarm Remote Signaling Nipple Product Wire Size Response Time Product Warranty Max. Surge Current/Phase 5/6/4 HZ -4 TO +185 F (-1 TO +85C) Up to -5dB all Models 2, kaic Fusing/Mode 5, CAT C3 Surges without Drift Compliant Yes L-N, L-G, N-G, L-L Yes Form C Dry Contacts #1 AWG, 24 Leads < 5 Nano Seconds 1 Years 3 Models 1, Amps/Phase - 5, Amps/Mode, L-N, L-G, N-G, L-L 2, Amps/Phase - 1, Amps/Mode, L-N, L-G, N-G, L-L 3, Amps/Phase - 15, Amps/Mode, L-N, L-G, N-G, L-L NEMA 4 Nipple NEMA 4X disconnect NEMA 1 - Surface Mount / Flush Mount OPTIONS Safety Features Enclosure Rating Surge Counter Connection Weight Diagnostics Additional Enclosures Fused Safety Disconnect Nipple product; NEMA 4. Hardwire; NEMA 4X /NEMA1 Optional on all models #1 AWG wires NEMA 4 - Terminals.#1- NEMA 4 = 4 lbs.; NEMA 4X Hard Wired w/o disconnect = 15 lbs. NEMA 4X Hard-wired w/disconnect = 16 lbs.flush Mount 15Lbs Green Status LED s per phase w/audible alarm & dry contacts Stainless Steel, Flush-mount, NEMA1 *Drawings not to scale. PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

16 HURRICANE 5 C o m m e r c i a l G r a d e S u r g e P r o t e c t i o n O V E R V I E W : The Hurricane 5 Series Surge Suppressors provide high risk surge suppression capability at your facility s service entrance for both conducted (1/35µs) and induced (8/2 µs) transient over voltages originating from such sources as lightning strikes and utility switching. These protectors incorporate reliable high intensity replaceable modules (per mode) with individually monitored and fused MOVs. Designed to various national and international standards, the Hurricane 5 Series products are ideal as a global protection solution. The Hurricane 5 Series products come in five models, 1, Amp, 2, Amp, 3, Amp, 4, Amp and 6, Amp, and are versatile and scaleable to meet an array of engineering designs. The Hurricane 5 Series products are housed in a NEMA4 enclosure and they come standard with a 2kAIC rating to meet the most demanding needs. Noise filtration up to -5dB is incorporated providing protection in all modes and is available with or without a fused disconnect to meet all applications. Mode Level Field Replaceable Modules Available in Four, Seven and Ten Mode Configurations Eliminate Down Time & Keep Equipment Protected F E A T U R E S : UL1449 3rd Edition listed cul listed LED Status Indicators Audible Alarm Push To Test NO/NC Dry Contacts NEMA4 & Nema4X Enclosure Noise Filtering Sine Wave Tracking Circuitry Fused Safety Disconnect Switch (Option) Available in 4-7 & 1 Mode Design Heavy Duty Modular Construction Individual Modules Replaceable By Mode Digital Surge Counter 1 Year Warranty PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

17 HURRICANE C o m m e r c i a l G r a d e S u r g e P r o t e c t i o n MODEL (SERIES) H1C H2C H3C H4C H5C H6C H7C H8C H9C Nominal Line Voltage 12/24 12/28 24/12 277/48 48D 347/6 6D 22/38 24D MCOV 15V 15V 3/15V 35V 6V 48V 75V 25V 25V Voltage Protection Rating (VPR) Per UL1449, 3rd Ed. 6V 6V 9/6V 12V 18V 15V 2V 9V 9V Nominal Discharge Current (In): 8/2 2KA 2KA 2KA 2KA 2KA 2KA 2KA 2KA 2KA Model Number: HXC1 HXC15 HXC2 HXC25 HXC3 HXC35 HXC4 HXC6 Max. Discharge Current (Imax) 1KA 15KA 2KA 25KA 3KA 35KA 4KA 6KA Operating Frequency Operating Temperature 5/6/4 HZ -4 TO +16 F (-1 TO +7C) 2, surge amp product / with or without disconnect *Drawings not to scale EMI/RFI Noise Rejection Up to -5dB all Models Fault Current Fusing 2, kaic Pulse Life 5, CAT C3 Surges without Drift SINE Wave Tracking Yes UL 1283 Compliant Protection Modes L-N, L-G, N-G, L-L (where applicable) Audible Alarm Remote Signaling Yes Form C Dry Contacts 4, and 6, surge amp product / with or without disconnect Response Time < 5 Nano Seconds Product Warranty 1 Years Max. Surge Current/Phase 8 Models Connection Weight Enclosure Ratings Surge Counter Diagnostics Options 1, Amps/Phase 5, Amps/Mode, L-N, L-G, N-G, L-L 2, Amps/Phase 1, Amps/Mode, L-N, L-G, N-G, L-L 25, Amps/Phase 125, Amps/Mode, L-N, L-G, N-G, L-L 3, Amps/Phase 15, Amps/Mode, L-N, L-G, N-G, L-L 35, Amps/Phase 175, Amps/Mode, L-N, L-G, N-G, L-L 4, Amps/Phase 2, Amps/Mode, L-N, L-G, N-G, L-L 6, Amps/Phase 3, Amps/Mode, L-N, L-G, N-G, L-L Terminals #1-#2 AWG 1, - 15, Amps/Phase = 25 lbs. 2, - 25, Amps/Phase = 26 lbs. 3, -35, Amps/Phase = 27 lbs. 4,Amps/Phase = 28 lbs. 6,Amps/Phase = 38 lbs. NEMA 4, and 4X Version Yes Red-Green LED s, Dry Contacts, Audible Alarm, and Push To Test Nema 4X Enclosure - Fused Internal & External Safety Disconnect Field Replaceable by Modules. No Tools Required, No wires To disconnect PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

18 Typoon Large Thermal Capacity Electrodes Strong Aluminium Housing 15+ Pounds of Pressure Vortexx-Cap Vortexx-Cap P H : F A X : e m a i l : sales@pspproducts.com 8535 Phoenix Dr., Manassas, VA 211 No Fuel to Burn Low Dynamic Resistance & Low Residual Voltage Single, Distribution- Grade Varistor - No

19 DC Signal Line Surge Protectors MJ8 Series lmax 2-4kA Dimensions (in mm) (Screw Lug) MJ8-CAT5E Electrical Diagram (Din Rail Option) The MJ8 Series is designed to protect sensitive data-monitoring equipment connected to various network protocols from transient over voltages. P: 3-electrode gas tube D: 2-pole diode P D The MJ8 Series surge protector is deployed in a RS-485 signal network applications with data transmission speeds of up to1 Mbps. The surge protector is housed in a shielded enclosure with high quality shielded RJ45 jacks. The transient protection circuit is based on high energy gas discharge tubes (GDT) and a network of fast response silicon avalanche diodes (SAD) to achieve sharp clamping of very large surge events. 2 1 (MHz) Insertion Loss MHz 4 Characteristics 6 (db) PSP part number MJ8-CAT5E MJ8-12V MJ8-ISDN MJ8-17V Max. data rate 1 Mbps 1 Mbps 1 Mbps 1 Mbps Max. DC Supply 8 Vdc 18 Vdc 6 Vdc 18 Vdc 6 ma 6 ma 6 ma 6 ma 2 Pinouts (1-2) (3-6) (1-2) (3-6) (3-6) (4-5) (1-2) (3-6) (4-5) (7-8) (4-5) (7-8) (4-5) (7-8) Nominal discharge currents: 4 -Line/Line 2 8/2 -Line/Ground 2 8/2 6 Connections: -input -output Pinout Enclosure Ground Connection Standard Compliance Shielded RJ Connectors Shielded RJ Connectors 2 wires + shielding + ground Metal Screw Lug, Din Rail Clip or Mounting Flange IEEE 82-3af (transmission) IEC (surge withstand) 8 (db) 1 (MHz) 1 (MHz) Return Loss 2 1 MHz NEXT 2 1 MHz 4 6 (db) red curve: maximum limit PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

20 Residential Light Commercial Applications GEN-16-SER Service Entrance Rated Generator Transfer Switch Surge Protector Type 1 Device - No Breaker Required For Installation GEN-16-SER Overview Green Light Indicates Protection is Active The GEN-16-SER is designed to be the first line of defense against damaging electrical surges and spikes originating from utility power lines. The GEN-16-SER is U.L. Approved and designed for installation at the Utility Entrance of the generator transfer switch. providing robust protection for both the transfer switch and the whole home against damaging electrical surges and spikes. Generator Transfer Switch Surge Protector Phone UL Approved for Installation on Service Entrance Side of Generator Transfer Switch before main breaker GEN-16-SER Transfer Switch Protector Features UL Approved for installation on the service entrance side of Generator Transfer Switches. Flush mount plate option available for finished walls. Common mode suppression with 16, Surge Amp Capacity. Thermal fused metal oxide varistor (MOV) suppression technology. Light-emitting diode (LED) visual indicator for transfer switch protection status. Type 4 Enclosure suitable for transfer switches installed inside or outdoors. Provides whole house surge protection. PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

21 GEN-16-SER Service Entrance Rated Generator Transfer Switch Surge Protector GEN-16-SER Specifications Electrical Model Surge Protection Device (SPD) Type to UL Operating AC Voltage Maximum Continuous Operating AC Voltage (MCOV): Line-Neutral Nominal Discharge Current [I n ] Line-Ground Neutral-Ground Line-Line Maximum Surge Current Capacity [I ]: Line-Neutral max Fault Current Rating Voltage Protection Rating (VPR): Suppression Technology Mechanical Line-Ground Neutral-Ground Line-Line Line-Neutral Line-Ground Neutral-Ground Connection Terminal (Suppression) Hardwired Operation Temperature ( C) Enclosure Type (Outdoor) Enclosure Dimension (L W H) Weight Line-Line GEN-16-SER Type 1 Service Entrance Rated 12/24V Single Phase 3W+G 14 V 14 V 14 V 28 V 2 ka 8 ka 8 ka 8 ka 1 ka 1kA No Breaker 2ka With Breaker 6 V 6V 6 V 1V MOV #12 AWG pigtail leads -4 C to +8 C Type 4 PVC Plastic [ mm] 2.5 lbs [1.81 kg] Pr oduc t Diagram [294.14] [62.31] 2.45 [11.6] 4. [8. [32.46] [5.8] [8. [5.8] 2. [13.43] [mm] inches Optional Flush Mount Cover PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

22 Commercial Surge Protection Devices Din Rail Surge Protection A.C. Din Rail Products. Available from 4, to 2, surge amp capacity. Dry contacts and visual indicators available on all products. Noise filtration assemblies available in all voltages. Din Rail DC Power Surge Protector DC Surge Protection From 12 to 35 Volts DC These devices are based on high energy varistors (MOV) matched with the DC operating voltage (from 12 to 35 Vdc). The MOV are equipped with internal thermal disconnectors in order to provide safe end of life. Din Rail In-Line Data Surge Devices 2 and 4 pair Series Din Rail Surge Protection for Telephone ADSL/SDSL- SHDSL, ISDN, Fipway, Fieldbus-H2, 4-2mA, RS232 & RS485, MIC/T2 1BaseTProducts. Available from 6 to 15 DC voltage. 2, surge amp capacity. Pop out field replaceable modules. CCTV & Cable Protection The P8AX series coaxial surge protectors have been designed to protect antennas, microwaves, broadband applications, two-way radios, cellular, GPS and CATV equipment against lightning surges and electrical transients. They are a first line of defense for your sensitive equipment. Available in a broad selection of connector types. Two/Four Pair Data Line Protector RJ45/RJ45 POE Surge Protector Modulse B18/48 series are wall mount DC signal line surge protectors designed to protect your sensitive telephone, data com and instrumentation equipment against harmful lightning surges and electrical transients The MJ8/MJ8POE Series is designed to protect sensitive data-monitoring equipment connected to various network protocols from transient over voltages. The transient protection circuit is based on high energy gas discharge tubes (GDT) and a network of fast response silicon avalanche diodes (SAD) to achieve sharp clamping of very large surge events. Type 1 PV Surge Protectors 1CA DC Photovoltaic Surge Protectors 5 to 1 Volts DC with 4, Amps Imax Plug Strips & Point of Use Devices Commercial grade plug strips and point of use devices available Type 1 UL 1CA DC SPD with High Energy MOV s, Imax 4 ka modular design with UL th edition listing. Available in 5, 6, 8 and 1 Volts DC configurations. Din Rail Mountable.

23 PSP Model Number Nomenclature Hurricane Series Selection Chart Voltage Selections 1 = 12/24 Volt Single Phase WYE 2 = 12/28 Volt Three Phase WYE 3 = 12/24 Split Phase Delta High Leg 4 = 277/48 Volt Three Phase WYE 5 = 48 Volt Delta 6 = 347/6 Volt Three Phase WYE 7 = 6 Volt 3 Phase Delta 8 = 22/38 Volt Three Phase WYE 9 = 24 Volt 3 Phase Delta Fault Current Selections A=22 KAIC C=2 KAIC Surge Current Selections 1 = 1, Amps Per Phase 2 = 2, Amps Per Phase 3 = 3, Amps Per Phase 4 = 4, Amps Per Phase 6 = 6, Amps Per Phase Enclosure Selections 1 = NEMA 1 4 = NEMA 4 4X=NEMA4X 4XSS = NEMA 4X Stainless Steel Connection Selections N = Straight Nipple (Cooper 651S) With #1 Wire SFM = Surface Flush Mount Hardwire HW = Hard Wire HWD = Hardwire With Disconnect MHW = Modular Hardwire MHWD = Modular Hard Wire With Disconnect C = Surge Counter Hurricane Series Example H2C2-4-N-C H = Hurricane Series, 2 = 12/28 Volt Three Phase WYE C = Fault Current 2 KAIC, 2 = SURGE CURRENT 2, PER PHASE 4 = Enclosure NEMA 4 N = Connection Straight Nipple With #1 Wire C = Surge Counter PSP Products Inc Phoenix Drive, Manassas VA sales@pspproducts.com

24 1 Year Warranty PSP Products will, at its option, repair or replace any Vortexx brand. product that is defective or is damaged by an electrical surge (including those caused by lightning) for a period of ten (1) years from date of purchase. For technical assistance call The above coverage applies to the original end user purchaser only and is the exclusive remedy under this warranty, whether based in contract, tort, including negligence, or otherwise. Claims must be made within 3 days of damage. This warranty does not cover damage associated with sustained over voltages, vandalism, theft, normal wear and tear, obsolescence, abuse, no authorized, modification or alteration, misuse, improper installation or catastrophic events. Except as expressly provided by this warranty. PSP Products disclaims liability for any incidental, indirect, special or consequential damages arising out of the sale or use of any PSP products (including without limitation lost business profits, loss of data and all freight, mileage, travel time and insurance charges associated with warranty coverage claims). Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusions may not apply to you. This warranty gives you specific legal rights and you may have other rights which vary from state to state. This warranty is valid in the United States and Canada only. PSP Products Inc. P.O. Box 418 Manassas, VA 218

Applications. Remote Display Mounting Kits

Applications. Remote Display Mounting Kits June 200 Sheet 105 Surge Protection Products TVSS General Description Clipper Power System Visor Series.1-5 Clipper Power System Visor Series General Description Eaton s Cutler-Hammer leading-edge surge

More information

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A SURGE PROTECTIVE DEVICES (SPDs) INTEGRATED UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective

More information

CPS 100 480Y S K CPS 100 480Y S C

CPS 100 480Y S K CPS 100 480Y S C Ref. No. 1299 Visor Series Ordering Guidelines Table.1-4. Retrofit Surge Protection Products TVSS General Description Clipper Power System Visor Series CPS 100 480Y S K.1-9 Surge Ratings 100 = /phase 120

More information

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B SURGE PROTECTIVE DEVICES (SPDs) EXTERNAL SIDEMOUNT UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective

More information

Power surges can also be generated by equipment in your facility such as:

Power surges can also be generated by equipment in your facility such as: Power Quality Surge Suppressors What is Surge Protection A surge suppressor can be the first and best defense against the instant or gradual destruction of electrical equipment. Compared to the replacement

More information

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1 Page 1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Divisions 1 Specification sections apply to

More information

Surgelogic Surge Protection Device EMA, EBA, and HWA Series

Surgelogic Surge Protection Device EMA, EBA, and HWA Series Surgelogic Surge Protection Device EM, EB, and HW Series atalog 1310T0202R5/07 2007 lass 1310 OTETS Description..............................................Page Product Descriptions..........................................

More information

Surgelogic Surge Protective Device (SPD)

Surgelogic Surge Protective Device (SPD) Surgelogic Surge Protective Device () EB, EM, and HW Series atalog 1310T0202R05/09 2009 lass 1310 OTETS Description............................................. Page Product Description...........................................2

More information

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch

More information

TSn SERIES Surge Protective Device

TSn SERIES Surge Protective Device Page: 1 of 8 TSn SERIES Surge Protective Installation & Operation Manual 3621 Saunders Avenue www.systems.us Ph 804.355.1100 Richmond, VA 23227 4354 Sales@Systems.us Fax 804.355.8900 Page: 2 of 8 Quick

More information

Intersection Preassembled 19-inch Rack

Intersection Preassembled 19-inch Rack Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion

More information

SURGELOGIC TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage

SURGELOGIC TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage Internal and External Mounted TVSS Retrofit or New Construction Low Let-through Levels High Surge Capacities Internal

More information

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog APC DIN Rail Control Panel Mounting Uninterruptible Power Supply Catalog 2014 Contents Introduction, description... 4 Specifications...5 References....6 Dimensions...7 Wiring diagrams....8 Product reference

More information

Gas Discharge Tubes GTCX36-XXXM-R05 Series

Gas Discharge Tubes GTCX36-XXXM-R05 Series GTCX36-XXXM-R05 Series TE Circuit Protection 6mm 3Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data

More information

surge protection solutions

surge protection solutions Surge protection devices Innovative Technology Innovative and reliable surge protection solutions Eaton Innovative Technology SPD products Innovative Technology products are a part of Eaton s electrical

More information

Uninterruptible Power Supply

Uninterruptible Power Supply 96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

MLH REVISIONS NOTICE: THE INFORMATION AND DESIGN CONTAINED HEREIN IS THE PROPERTY OF TRANSTECTOR SYSTEMS. WHO RESERVES ALL

MLH REVISIONS NOTICE: THE INFORMATION AND DESIGN CONTAINED HEREIN IS THE PROPERTY OF TRANSTECTOR SYSTEMS. WHO RESERVES ALL THIS DRWING HS BEEN GENERTED ND IS MINTINED BY CD SYSTEM. CHNGES SHLL ONLY BE INCORPORTED S DIRECTED BY THE DESIGN CTIVITY. REVISIONS LTR DESCRIPTION ECO NUM. DTE PPROVED B PRELIMINRY RELESE DD057 7/25/07

More information

Gas Discharge Tubes GTCX26-XXXM-R05 Series

Gas Discharge Tubes GTCX26-XXXM-R05 Series Raychem Circuit Protection 6mm 2Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data transmission lines

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Battery Power Inverters

Battery Power Inverters Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.1 Important Safety Instructions Please save these instructions.

More information

Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8

Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8 Door Mount UPS (Patent Pending) Shelf Mount UPS (Patent Pending) DESCRIPTION: The Always On NDM (door mount) and NSM (shelf mount) Series UPS s are dual conversion online UPS systems provided in slim,

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Transient and Lightning Protection for the Water Industries

Transient and Lightning Protection for the Water Industries Transient and Lightning Protection for the Water Industries Mike Nager Phoenix Contact mnager@phoenixcon.com 5 th ISA Water/Wastewater Automatic Controls Division Symposium (WWAC) August 3-5, Orlando,

More information

mpm DIN 43650 CONNECTORS

mpm DIN 43650 CONNECTORS mpm DIN 43650 CONNECTORS : Highest quality, robust connectors for hydraulic and pneumatic electromechanical devices Broad offering of DIN 43650 connectors and devices Combined Brad and mpm cordsets : Provide

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

SUPERSEDED REVISION. Gas Discharge Tubes GTCX28-XXXM-R20 Series. Features: Benefits: Applications

SUPERSEDED REVISION. Gas Discharge Tubes GTCX28-XXXM-R20 Series. Features: Benefits: Applications GTCX28-XXXM-R20 Series Raychem Circuit Protection 8mm 2Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and

More information

Model #: SMART2200CRMXL

Model #: SMART2200CRMXL Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

BC Pro UPS System Standby UPS System

BC Pro UPS System Standby UPS System BC Pro UPS System Standby UPS System Model #: BCPRO1400 1400VA standby, tower UPS system Offers battery derived AC output during blackouts and brownouts starting at 99V 6 protected AC outlets (NEMA 5-15R)

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

Water Leak Detection System

Water Leak Detection System Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright

More information

Broadband Telecommunications Drop Amplifier

Broadband Telecommunications Drop Amplifier INSTALL SHEET BDA Broadband Telecommunications Drop Amplifier Introduction The Broadband Telecommunications Drop Amplifier (BDA) is a two-way, 1 GHz amplifier designed for customer-premise amplification

More information

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014 EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware

More information

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS

More information

Wireless Broadband Surge Protection

Wireless Broadband Surge Protection X1 01 00 03 D4 P1 P2 X2 Wireless Broadband Surge Protection UNPROTECTED PROTECTED Wireless Broadband Surge Protection The demand for high-speed wireless internet and data network access over a wide area

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide M7250P PoE Powered Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX Installation Guide September 2009 VERSITRON, Inc. 83 Albe Drive - Suite C Newark, DE 19702 www.versitron.com www.versitron.com

More information

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a

More information

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the

More information

Single Station Remote Alarm

Single Station Remote Alarm ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation

More information

MTL Surge Technologies. Product Overview

MTL Surge Technologies. Product Overview MTL Surge Technologies Product Overview Surge Protection Devices Today s modern electronic systems, such as those designed for process control and high-speed communication, rely heavily on very sensitive,

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications

More information

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Installation and Operation Guide for PD4000 Series Power Control Center

Installation and Operation Guide for PD4000 Series Power Control Center Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your

More information

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V APC Smart-UPS, 670 Watts / 1000 VA,Input 230V / Output 230V, Interface Port DB-9 RS-232, SmartSlot, USB Includes: CD with software, Smart UPS signalling

More information

8-Port PoE Network Switch

8-Port PoE Network Switch Page 1 of 12 8-Port PoE Network Switch User s Guide Document Number 91I00-1 Rev A August, 2009 FCC Warning: Page 2 of 12 This devices has been tested and found to comply with the regulations for Class

More information

Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server

Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server NETRS232485 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com

More information

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system Model #: SMART500RT1U 500VA line interactive 1U rack/tower UPS 7 outlets with 1 switchable load bank Simultaneous

More information

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Industrial Ringdown/Autodialer Telephone SCR Series

Industrial Ringdown/Autodialer Telephone SCR Series Industrial Communications Worldwide Industrial Ringdown/Autodialer Telephone Installation & Operation SCR 11 SCR 41 P005603 Rev. A 060612 5/28/2007 3:58 PM 7552-10th Street N.E. Calgary, Alberta, Canada

More information

Canopy Surge. User Manual

Canopy Surge. User Manual Canopy Surge Suppressor User Manual SS00-UM-en Issue 2 May 2003 2003 Motorola, Inc. All rights reserved. Printed in the U.S.A Notices Safety Precautions: Before beginning your installation, please read

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering

More information

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit

More information

Table of Contents. TransformerIQ FAQs 1

Table of Contents. TransformerIQ FAQs 1 [12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is

More information

Internet Office UPS System Standby UPS for PCs, workstations and more

Internet Office UPS System Standby UPS for PCs, workstations and more Internet Office UPS System Standby UPS for PCs, workstations and more Model #: INTERNETOFFICE500 500VA standby tower UPS system Offers battery-derived AC output during blackouts and brownouts starting

More information

Provides one channel for Ethernet over existing

Provides one channel for Ethernet over existing LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information

More information

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN -

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011 Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

BLUE RIBBON CORP. BC001 Birdcage Installation Manual Product Overview: This manual is applicable for the BC001 Birdcage Submersible Level Transmitters. If the product you have has a different prefix part number than listed above please contact the factory

More information

SingleNet Single Cable Control System

SingleNet Single Cable Control System Single Cable Control System Economical, Reliable and Expandable Two-Wire Single Cable System DRIP/MICRO IRRIGATION PRODUCTS Single Cable Control System System Manager or Irrigation Controller Controls

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMART500RT1U Description Tripp Lite's SMART500RT1U intelligent, line-interactive rack/tower uninterruptible

More information

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS Smart-UPS Advanced line interactive power protection for servers and network equipment The world s most popular network and server UPS The award-winning Smart-UPS unit from APC by Schneider Electric is

More information

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5 AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC

More information

I STAR COMPUTER CO., LTD

I STAR COMPUTER CO., LTD I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON

More information

Mobile Data Power Model: MDP-25

Mobile Data Power Model: MDP-25 Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

AN 17.18. SMSC Design Guide for Power Over Ethernet Applications. 1 Introduction. 1.1 Power Over Ethernet

AN 17.18. SMSC Design Guide for Power Over Ethernet Applications. 1 Introduction. 1.1 Power Over Ethernet AN 17.18 SMSC Design Guide for Power Over Ethernet Applications 1 Introduction 1.1 Power Over Ethernet Power over Ethernet (POE) has emerged as a practical method of providing power to Ethernet devices

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

Operation and Installation Manual

Operation and Installation Manual Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control

More information

Telecommunication Line Protectors

Telecommunication Line Protectors TN CR 0025 Telecommunication Line s 1.1 The nature of telecom surges The telecom services considered in this report are transported on twisted pair. Each service has two wires, or lines, sometimes called

More information

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SM1000RM1UTAA Description Tripp Lite SM1000RM1UTAA 1000VA / 1kVA / 800 watt line

More information

Gas Discharge Tubes GTCX38-XXXM-R10 Series

Gas Discharge Tubes GTCX38-XXXM-R10 Series GTCX38-XXXM-R10 Series TE Circuit Protection 8mm 3Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data

More information

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility

More information

A series of technology briefs spanning Tyco Electronics product portfolio

A series of technology briefs spanning Tyco Electronics product portfolio A series of technology briefs spanning Tyco Electronics product portfolio Coordinated Circuit Protection Schemes Help Prevent Overvoltage and Overcurrent Damage Through advances in materials science and

More information

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters AP-XC-025 Revision B DANGER RISK OF ELECTRIC SHOCK, EXPLOSION, ARC FLASH, AND FIRE This Application Note is in addition to, and

More information

Protect your home and family with Advanced Technology from Cutler-Hammer

Protect your home and family with Advanced Technology from Cutler-Hammer Protect your home and family with Advanced Technology from Cutler-Hammer Residential Home Fire Statistics Annually - over 415,000 Residential Fires Annually - over 40,000 electrical fires over 350 deaths

More information

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1 Overview It's getting harder to manage a data center efficiently, with rising utility bills and ever-increasing demands due to processor power and server density increases. Growing user requests mean heavier

More information