Blackwood Fire Company. Engine Company Operations

Size: px
Start display at page:

Download "Blackwood Fire Company. Engine Company Operations"

Transcription

1 Blackwood Fire Company

2 Force, when used, should be overwhelming and disproportionate to the force used by the enemy. Colin Powell 2

3 3

4 Basics The basic unit of any fire department, the engine company performs the cornerstone task of extinguishing fire. Our engines are identical and are equipped with 1500 GPM single stage fire pumps and 750 gallon water tanks. Each engine also carries a foam tank with 50 gallons of alcohol resistant aqueous film forming foam (AR-AFFF). The engines are designed for versatility. Numerous fire attack options are possible considering hose length, size and nozzle type. The engines are also equipped for supporting roles at accidents, medical emergencies and routine investigation assignments. Basic Company Operations Structure Fires The team concept for engine operations works slightly different than truck or rescue company operations. All members of the engine must function as a unit to ensure the nozzle reaches the seat of the fire without delay and a continuous water supply is established. There are several key points to the Blackwood Fire Company engine company philosophy: Water supply is established early and sustained. Hand lines are pumped properly for the required flow. A back up line is always pulled to the point of entrance. Big lines are readily available and their use is dictated by the fire, not available manpower. The Truck Company must be safe to operate in the structure without their own hand line. The Engine Officer is inside with his line and will not back out of a fire situation without ensuring the safety of the Truck Company. Always use more force than you think necessary to overwhelm the fire. 4

5 Engine Company Riding Assignments Driver The driver is responsible for getting the supply line in the street or providing water to engine arriving prior. Driver should be prepared to serve as an initial FAST for 2 in 2 out in minimum manning situations. At a minimum the driver should attempt to monitor his crews activities to provide accountability. Assists in deploying lines. Clears the bed, chases kinks between engine and front door. Charges line to pre designated engine pressure when requested. Hooks up supply line. Returns to hydrant for hook up in extraordinary situations. Uses generator and lights for scene lighting. Maintains water flow, supplies additional lines, monitors progress. Assists all companies as necessary in immediate vicinity of engine. Officer Responsible for locating water supply and most direct route to scene. Determines hydrants based on order of arrival and by monitoring radio. Determines hose size / length for attack or back up Determines best route to stretch line. Teams with nozzle firefighter and back up. Equipped with radio, light, TIC. Seat 1 Nozzle Stretches correct line as directed. Maintains sufficient line at entrance to make seat of fire. Keeps a working length available to stretch in. Operates nozzle to extinguish or control fire Seat 2 Back Up 4 man company Initial FAST Assists in deploying line Forces entry as required Feeds line from door way Chases kinks on fire floor 5

6 5 man company Assists in deploying line Moves in with nozzle man Keeps line moving smoothly on interior and backs up nozzle man Seat 3 Door Initial FAST Assists in deploying line Forces entry if required Feeds line from door, moves in with first coupling and keeps line moving. Chases kinks from door to fire floor Seat 4 Hydrant Makes up hydrant connection COLD water hook up 5 directly to large hydrant port and gate valves on both small ports. Cold water hook up on dwellings is OK. Engine hook up 5 to largest discharge, No kinks between hydrant and pump, Use all hydrant ports. Commercial buildings greater than 200 lay. Returns to assist Seat 3 Seat 5 & 6 are extras and are assigned by the officer. Except in extraordinary cases or where no truck company is available, all extra engine personnel should be assigned to establish water supply and support the advance of the hose line to the seat of the fire before getting additional lines in service. Fire Ground Position The engine driver and officer must always work together to ensure the engine is positioned to effectively attack the fire, while not interfering with apparatus that have greater operational limits. The engine can quickly stretch several hundred feet of hose while the tower must be within 80 of the building and the rescue must be within 80 of an accident to take full advantage of their equipment. Structure Fires Unless it will create an undue delay or eliminate a water supply, the 1 st engine should seek to enter the fire location from the opposite direction of the tower or allow the tower to enter the street first. 6

7 The engine should be placed at least 75 beyond the front door of the fire building. The engine must allow enough room for the tower to position their turntable centerline of the building or toward the most likely exposure. Engines must be no closer than 30 to the rear of operating ladder companies to allow for removal of ground ladders. Highway Incidents The initial arriving engine should position to block the scene and still attack the fire or provide fire suppression at an MVA. The engine should remain approximately 100 behind the scene, allowing room for engine firefighters, the rescue and ambulances to work in a protected area. Where conditions require the engine to operate in a position past the involved vehicle (uphill or upwind) Additional traffic control measures will be required from other responding apparatus. Water Supply This is where it starts. The key to success is establishing and maintaining a water supply. Each engine is equipped with 1200' of 5" hose. The hose is finished in a bundle to allow it to lie in the street without wrapping an object. The hydrant bag (center) contains fittings and tools to establish water supply given almost any circumstance. Standard orders require the first engine to provide the water supply. The officer of the first engine has to determine the best way to accomplish this. In most cases it is the straight lay. The following are basic lays used by the Company. 7

8 Types of Hose Lays Straight Lay or Forward Lay ( Lay In ) The engine stops on the way in, drops the 5 hose bundle in front of the hydrant, and lays into the scene. If necessary, a second engine responds to and pumps the hydrant. The advantage here is that the work is done prior to arrival and it is the fastest sustained water supply. The disadvantage is that the second engine may have its crew and all equipment quite a distance from the fire. Reverse Lay ( Lay Out ) Starting at the scene, an engine lays to the hydrant and pumps the line. The advantage here is that the crew and equipment on the engine can be deployed before it starts its lay. The disadvantage is trying to get into the fire scene and maneuver back to the hydrant with additional apparatus responding in. A reverse lay can be used to provide a supply line to an engine or tower already at the scene or the reverse lay could be a 3 or 4 hundred foot attack line laid from in front of the structure. Split Lay The first engine lays in partially (courts, driveways, parking lots) and the second engine either performs a reverse or straight lay to make up to the partial lay. One In / One Out - Used when a high fire flow situation is noted on arrival. The tower ladder will straight lay 1 line in and the first engine will reverse lay one line out to another hydrant. The first engine will pump its line and assign its crew to the tower ladder to deploy lines. This concept gives us the advantage of high flows immediately on arrival of the first 2 pieces. It also provides flexibility as the incident grows to add an engine to pump the first line, or split water supply up for other companies. Layout Instructions The first engine officer must make clear communications on arrival to sustain water flow. An example would be: Engine 841 arriving at 201 State St with heavy smoke from floor 2 of a 2 story single family dwelling, we laid in from the hydrant at Lake and State Streets. Have the 2nd due engine pump the hydrant, send their crew forward for the backup line. The driver of the 2nd due engine will make all necessary connections while his crew proceeds to Engine 841 to stretch a back up line. After the 2nd due has acknowledged their actions, additional engine companies should reference their map books and locate the 2nd water supply. The 3rd and 4th due should also take note of the location of tower ladders on the fire ground as their water supply may become a high priority if 1 5 line is insufficient. 8

9 Water Supply Basics No personnel should ride the back step while hose is being laid. The apparatus should not exceed 20 mph and should attempt to remain to the hydrant side of the street when laying line. Kinks are major flow killers for LDH. Make sure all bends are smooth and the line is not kinked. Taking the time to do this pays off on the other end. If necessary, notify command and shut down lines to resolve major kinks. Take advantage of all hydrant ports. Install gate valves on both 2 ½ ports for using all available water. Use 5" for these supplies where possible. Discharge through the largest discharge ports on the engine. Side discharges toward the rear of the apparatus are full flow discharges. Ensure all valves are FULLY open and then lock them in place. High flows can cause valves to slowly go closed if not locked. Maintain desired pressure (do not exceed 185 psi discharge pressure on LDH) Use 2 ½ x 5" adapters for 2 barrel hydrants. When charging 5 lines, start at hydrant pressure and open the gate to the 5 discharge. Note the pressure on the suction gauge prior to opening the 5. That is the static pressure. The pressure remaining with water flowing is the residual pressure. Unless otherwise directed, pump the 5 hose at 150 psi when requested to charge the line. Relay Operations 5 hose has a functional limit of about 1500 GPM. Friction loss at 1500 GPM allows for a hose lay of about 800 feet between fire and hydrant. For distances greater than 800 feet a relay pumper is required. The relay pumper should be positioned to take a supply in through its largest intake and out through its largest discharge port. The pump operator opens both valves fully and locks them in position. The relay pump operator increases his pressure until he holds a 20 psi residual pressure. No additional actions are required by any of the pump operators in relay except for the scene and supply engines. All intermediate relay pump operators merely adjust pressure to maintain 20 psi residual. Relay pump operators should maintain radio silence except to report a problem. 9

10 Attack Hose Nozzle Nozzle Flow Tank NFA FF Pressure Duration 1 ¾ 15/16 SB GPM 4 minutes 555 sq. ft. 1 ¾ TFT GPM 4 minutes 555 sq. ft. 2 1/2" 1 ¼ SB GPM 2: sq. ft. 3 1 ½ SB GPM 1: sq. ft. Deck Gun Fog Tip GPM 45 sec sq. ft. Deck Gun 2 SB GPM 45 sec sq. ft. Deck Gun 1 ¾ SB GPM 56 sec sq. ft. Deck Gun 1 ½ SB GPM 1: sq. ft. Deck Gun 1 3/8 SB GPM 1: sq. ft. Once the water supply is established, the primary job of the engine company is to locate and kill the fire. Protection of escaping civilians and searching firefighters dictates how we approach this method. Extinguishing the fire saves lives, when in doubt, KILL the fire. Our attack lines are set up to deliver high flows for immediate knock down of fires from 500 to 1000 square feet. 1 ¾ attack lines use a mix of TFT low pressure nozzles and 15/16 smoothbore nozzles. Lines 2 ½ and larger use exclusively smoothbore nozzles. Each attack line has a pre determined pump pressure. This designated pressure is derived by determining the desired flow, type of nozzle, and length and diameter of hose. The pump operator sets the engine pressure (EP) based on this calculation and adds 5 lbs per 10 of elevation. This pressure is marked on the corresponding discharge gauge and is the standard pressure to which attack lines will be charged. The following formula is used to determine proper pump pressure: EP= NP + FL + E. EP= Engine Pressure, the pressure indicated on the individual discharge gauge. Set by adjusting the throttle and discharge gate. NP= Nozzle Pressure. Several nozzle pressures are used within the company. o Smooth bore tips for hand lines = 50 psi. o Smooth bore tips for fixed master streams = 80 psi. o TFT Midmatic fog tips = 75 psi. o Fog master stream tips = 100 psi. 10

11 FL= Friction loss is the loss of pressure as water is pumped through a hose. Friction loss is dependent on the diameter of the hose, the length of the hose and the actual flow. E = Elevation loss is the loss of pressure as water is pumped to levels above the engine. Elevation loss is about 5 lbs per 10 feet. Pumping a hand line to the 4th floor of a structure may cause a loss of up to 20 lbs. Pump operators must make adjustments for elevation. Although not frequently encountered, pressure will similarly increase when the pumper is in an elevated position to the discharge. Needed Fire Flow (NFF). Our philosophy is to utilize high flow hand lines to quickly overwhelm a fire. Selecting and operating the correct line should allow for knockdown within the first minutes. This is determined by utilizing the National Fire Academy (NFA) Quick Access Fire Flow Formula. Find the area of the building by multiplying length by width. Divide the result by 3 to establish fire flow. A 40 x 60 strip store occupies an area of 2400 square feet. The needed fire flow is 800 gpm if this store if completely involved. A dwelling with a 12 x 14 bedroom is 148 square feet, requiring a flow of approximately 50 GPM. Exceeding the fire flow does not cause water damage. Overwhelming a fire with a high flow line allows it to be shut down much more rapidly. Attack Line Selection The top left photo shows the cross lay area. From right to left, the following attack lines are: 200' 2 ½ hose with 1 1/4" smoothbore nozzle. Delivers 325 GPM at standard pump pressure 200' 1 3/4" hose with 15/16" smoothbore nozzle. Delivers 185 GPM at standard pump pressure 200' 1 3/4" hose with low pressure TFT Midmatic. Delivers 200 GPM at standard pump pressure. The cross lays are bundled so the nozzle man pulls the top 50 from the street and shoulders it. The back up and door man take remaining folds and the driver clears the bed. 11

12 The center photo shows the front bumper line. This line is generally used for nuisance or auto fires, but may be used on dwelling fires where the 150 length is sufficient. The front bumper line contains 150' 1 ¾ hose with a low pressure TFT Midmatic, preconnected in a Kentland Load. This line delivers 135 GPM at the standard pump pressure. 1" forestry line and a TFT nozzle are carried in the well above the pump panel. For use in structure fires, pressure is increased to reach the standard 1 ¾ flow of GPM. The extreme left of the right photo shows the 300' 1 ¾ line (green hose). This line is set up to deploy off of your shoulder (note the location of the nozzle low in the hose load). This line is equipped with a 15/16 smoothbore and will deliver 185 gpm at the standard pump pressure. Another option for long lines is the Leader Line (shown in the upper right photo with orange strap attached). This line uses 300 of 3 hose connected to a ¾ bundle. This line is equipped with a 15/16" smoothbore and will deliver 185 gpm at the standard pump pressure. Operating Procedures 1 ¾ hose lines are the initial attack line for most residential and some commercial fires. The first line off is equipped with a 15/16 smooth bore nozzle delivering 185 GPM at 50 psi. Smooth bore nozzles are operated only in the FULL OPEN position. Although not SOP, if the TFT nozzle is pulled first it should be operated FULL OPEN and in a straight stream pattern until the fire is controlled. Using the NFA formula, both of these lines are capable of achieving quick knock downs on fires in compartments up to about 600 square feet. Pre connected 1 ¾ lines are limited to 300. For distances greater than 300, use the Leader Line, or refer to the section on Wye Lines and Utility Rope stretch. The 2 ½ hose line should be considered for any working fire in a commercial occupancy and some residential uses. The 2 ½ hose line is equipped with a 1 ¼ smooth bore nozzle delivering 325 GPM at 50 psi. In most cases the use of the 2 ½ hand line will require the firefighters of 2 engine companies to deploy and move efficiently. Using the NFA formula, this line is capable of achieving quick knock down on fires in compartments up to about 1000 square feet. When longer lines are required than the 200 provided on each engine, 3 hose should be made up starting at the pump panel. Do NOT add extra lengths of the much heavier 3 hose in at the nozzle end. The use of the crews from 2 engine companies should be strongly considered when advancing 2 ½ hose into a building. 12

13 Some quick indications of when to use 2 ½ hand lines: Advanced fire conditions Conditions such that entry can not readily be made due to the amount of fire. Initial use of the 2 ½ may be quickly followed up with an interior attack using the same line or by attaching one or more lengths of 1 ¾ hose to the nozzle and stretching in. Defensive operations The use of the 2 ½ and the Bomb line are indicated for a quick exterior attack. These lines are far easier to get into service with limited manpower than master streams. As additional companies arrive, master streams can be deployed. Unable to determine fire area or extent of fire These conditions are most frequently found in larger commercial buildings. The uncertainty demands the use of a high flow line. Large, uncompartmented fire areas 1 ¾ hose works well on house fires because even a 3000 square foot house is broken down into individual manageable compartments. Commercial occupancies may have little to no compartmentation and wide open floor areas. The 2 ½ provides the reach and cooling stream necessary for deep penetration into these buildings. Attack Line Placement Single Family Dwellings In almost all cases, interior attacks will be made in residential buildings through the main entrance. This is particularly true in dwellings and apartments, where life hazards are greater, and access to stairs and sleeping areas is more readily available. Although an alternate entrance may allow for attack from the unburned side, the delay and obstacles encountered limit any advantage gained. The advantages to attacking at the main entrance are: Direct access to and protection of the main stairway. Allows firefighters to proceed to upper floors via stairs to search Allows victims to exit If there is no life hazard, the first hose line is positioned between the fire and most severe exposure. 13

14 The goal of the initial attack line is to advance to the seat of the fire and extinguish it. This could be considered the most dangerous position, as a loss of water or fire conditions that overwhelm the hose stream may endanger the initial hose crew or stall the fire attack. For this reason, the second line must be deployed to back up the first line, and should not be repositioned without the consent of the interior officer. The back up line is positioned where it will not interfere with the first line, but can immediately assist if the first hose crew is overwhelmed or experiences a failed length of hose or loss of water. If the first line is making good progress, it is expected that the back up line will go to the most severe exposure, generally the floor above, but possibly to the left or right. The back up line may have to be considerably longer than the attack line. A good rule of thumb is that no more than 2 hose lines should go through the same entrance. The weight of multiple hose lines will certainly slow or stop the progress of the first lines, and will create a fall hazard, particularly on steps. The officer of a hose crew assigned to stretch a line (when other lines have already been stretched) should walk the layout and determine the best route to the objective, taking care to avoid multiple hose lines through the same entrance. Basement fires Initial size up must always determine the fire location. A working basement fire is a critical situation. Take the time to check for exterior entry to the basement and announce the change of standard plan on the fire ground if exterior attack is warranted. The outside team of the truck should be ventilating windows and the 1 st floor as necessary, while the inside team performs a quick search and secures the 1 st floor basement door. Garden Apartments Garden apartments pose a significant challenge to the engine company. Limited access, setbacks and parking arrangements all combine to require longer stretches and closer attention to detail when deploying lines. The construction of garden apartments also lends itself to fire spread between units and the possibility of many residents being trapped by a lower floor fire. 14

15 1 ¾ line is sufficient for interior attack in most cases. The first line in a garden apartment fire has to go to the seat of the fire. Determining the floor of origin is critical. The back up line should be stretched to the fire floor or to the closest entrance. If released, back up can be deployed to an exposure apartment. General order of priority in placing hose lines at garden apartments follows below. A working fire in a multi story complex requires many lines quickly. Extra alarms are almost always required. 1 st line - Fire apartment Back up Fire apartment 2 nd line - Vertical exposures As indicated by fire conditions - Horizontal exposures 3 rd line - Alternate stretches to upper floors The use of 1 ¾ hose at lengths greater than 400 is questionable. The 300 line may be extended by 100 to quickly attack a fire. The 400 Leader Line is also an option. Additional extended lines will require the use of 3 hose, wyes and hose packs. Commercial Buildings Size up should include identifying the closest door to the fire area. Prior to committing to an attack position, the IC should use recon information from the Truck Company or the Engine Officer to determine the fastest route to the fire. The main entrance tactic can not be relied on due to wide varieties of building sizes and types. Locating a door with direct access to the fire area is the ideal condition. In most cases, 2 engine companies should be assigned to place the first 2 ½ line into operation. As previously stated, there are many reasons for using 2 ½ hose on commercial building fires. Engine company members should take full advantage of the extended reach of the large stream and ensure they control the fire before over committing. Truck Companies will generally remain with the line on commercial building fires, and the engine officer should request frequent checks of the ceiling / overhead to ensure fire is not traveling in voids overhead. Ventilation is much more likely to be delayed when compared to a residential structure. 15

16 Attack Line Deployment All attack lines are packed to facilitate the nozzle man reaching the objective with a working length of hose. This is accomplished in several ways: Front bumper Kentland load, nozzle man removes donut roll and proceeds to fire area entry. Cross lays 1 ¾ and 2 ½ attack lines are packed with the nozzle length bound with an inner tube and chock just behind the nozzle. These lines are deployed by grabbing the LONG loop from the ground and shoulder loading the pack. Additional firefighters shoulder load from the shorter loops. Rear lines both the ¾ and 3 Bomb lines are set up to be shoulder loaded, and are packed in a minuteman load with the nozzle under the last length of hose. The 400 leader line has 100 of 1 ¾ line arranged in a bundle load. This line may be deployed in close quarters and does not need to be flaked out. Attack lines should be carried and deployed off the shoulder whenever possible. This allows for maneuvering around obstacles and up stair wells and prevents snags and delays. The nozzle team is responsible for flaking the line and ensuring it moves quickly to the fire area with no kinks. Sprinklered Buildings The 2nd or 3rd due engine, depending on size up conditions, should supply the FD connection. Connections are generally in close proximity to hydrants. The engine should lay a 5 line from the hydrant to the area of the connection, connect to the sprinkler system with two 3 hose lines, and pump the lines at 150 psi.. Standpipes Standpipe hook ups are similar to sprinklered buildings, except that the size up should include: Height of building to stand pipe outlet: Add 5 psi per floor. Type of hose, nozzle and length of lay. 16

17 Engine pressure must account for: Friction loss in 3 to Siamese Elevation loss in standpipe Friction loss in appliances Friction loss in attack hose Nozzle pressure High Rise Pack The high rise packs are equipped with a gated wye for 2 ½ hose, and 100 of 1 ¾ hose. The line is equipped with a break apart nozzle, which consists of a 15/16 smooth bore tip with shutoff, and a low pressure TFT nozzle with a twist shut off. Engine companies should equip themselves for operations with 2 ½ hand lines when fire conditions dictate and stand pipes will support. Members should shoulder load lengths of hose and bring appropriate equipment to make the hook up. Wye Lines After the initial and back up lines are deployed, consider stretching a 3 line and gating it to provide 2 additional lines in exposed areas. The high rise pack provides the attack hose and gated wye. Use of Ladders A single hose line can be advanced rapidly over a ground ladder to an upper floor. The hose should be stretched dry to a safe area, sufficient hose pulled into the structure to reach the fire and the hose secured BEFORE calling for water. Utility Rope Stretch Particularly useful in large garden apartment complexes, a crew goes to the desired floor equipped with a high rise pack, forcible entry tools and the utility rope. Entry is gained to an apartment remote from the fire area, and a 3 line is stretched from the ground to the upper floor via the utility rope. The 3 is secured and the high rise pack provides the attack line. Utility ropes are stored with the high rise pack on each engine. 17

18 Blackwood Fire Company Big Guns For quickly delivering streams of 400 to 1250 GPM, we have the following options. The first 2 photos below show the Elkhart Stinger in the deck mounted mode. In this mode, the Stinger flows 1250 GPM and can be operated with the safety pin pulled, with no elevation restrictions. Do not exceed 150 psi inlet pressure. The photo to the right shows the stinger with The Pipe attached. This device elevates the gun approximately 18 inches to clear the cab roof and hose body. Use of this device requires practice by driver/operators to determine the effect the added height will have on the angle of attack and reach of the stream. The Stingers have a stream shaper and a set of stacked tips (1 3/8, 1 ½, 1 ¾, and 2 ). A 1000 GPM fog tip and a portable base for the Stinger are in compartment L-1. For portable use, another Stinger is located on the back step of each engine with a portable base and an anchor kit (lower right photo). Operation is the same as described above, except the flow is limited to 800 GPM, the unit can not safely be rotated more than 45 degrees to either side of the center leg, and should be anchored prior to use. The safety pin can not be pulled to lower the stream in this mode. Do not exceed 150 psi inlet pressure. The Bomb line (lower left photo) is a 3" line equipped with a 2 ½" full flow shut off and a 1 ½" master stream tip. This line is capable of flowing 400 to 600 GPM and should only be operated from a seated position or a hose loop. 18

19 Foam Operations Each engine is equipped with 50 gallons of Universal Gold Alcohol Resistant Aqueous Film Forming Foam (AR-AFFF), a 100 gpm JS-10 foam nozzle and a 100 gpm LP-9 foam eductor. This foam is for Class A and B Flammable Liquid firefighting. Hydrocarbon fuels such as gasoline and diesel require a setting of 1% while alcohol or polar solvent based fuels require a setting of 3%. Prior to deploying foam it is important to determine the required flow rate and how much foam will be required. Foam solution (foam/water mix) must be applied at a rate of.16 gpm per square foot of burning fuel. To be effective, foam solution must be applied for 15 minutes. We ll use a 1000 square foot gasoline fire as an example: 1000 x.16 gpm = 160 gallons of foam solution are required per minute to knock down and control the fire. Hydrocarbons require 1% foam..01 x 160 = 1.6 gallons of foam concentrate per minute. The foam must be applied for 15 minutes. 1.6 x 15 = 24 gallons of foam concentrate needed to extinguish the fire Since this evolution requires close to 1500 gallons of water, a hydrant supply line or other water supply must be established Since we have a 50 gallon on board foam concentrate tank, this is the practical limit for a single engine foam attack. Of course if both engines placed their lines into service simultaneously, this amount could be doubled. To utilize foam, take the following steps: Obtain the foam nozzle and eductor from compartment L-1. Deploy no more than 200' of 1 3/4" hose. Replace the existing nozzle with the JS-10 foam nozzle, Connect the eductor to a driver side discharge and connect the pick up tube to the small fitting on the lower left of the pump panel. Open the pump access panel and pull the foam discharge lever. Set the eductor to 1% for hydrocarbon (oil, gas, etc...) or 3% for alcohol fires. Pump the line at 200 psi 19

20 Foam should be applied to completely cover the burning fuel. Avoid plunging the stream into burning fuel. Allow the foam to gently cascade onto the fire by striking an object and allowing the stream to flow down onto the fuel, or bank it onto the fire by directing the stream at the ground in front of the fire and rolling it onto the burning liquid Do not mix foam and water streams, the water will weaken the foam and push it off the fuel. The nozzle must be maintained full open and the line kept free of kinks for efficient eductor operation. Foam Pro Pak The Pro Pak holds 2 ½ gallons of AFFF Universal Gold. This is firefighting foam with both Class A and B firefighting properties. Rated at psi. Most effective for vapor suppression at fuel spills, small class B fires and application of Class A foam for deep seated fires. Portable Fire Extinguishers The following types of portable fire extinguishers are maintained either on the engines or other apparatus. ABC Type Dry Chemical Effective on all types of fires but has particular use in quick knockdown of flammable liquid fires. Carried on all apparatus. The ABC chemical reacts with heat to form a film over any burned material. The powder can be damaging to electrical equipment and motors. We have both stored pressure and cartridge operated extinguishers in use. Pressurized Water Carried on all apparatus, consists of 2 1/2 gallons of water pressurized to 100 psi. Effective on Class A fires only, such as nuisance and trash fires. Can also be used to darken a room and contents fire while the attack line is being stretched. The PW extinguisher is carried by the Can positions on both the Rescue and Tower. 20

21 Indian Back Pack Effective on Class A fires only. Carried on both engines. Vest is filled with water at the scene and is hand pump operated for use on brush fires and nuisance fires out of the reach of a hose line. Aqueous Film Forming Foam (AFFF) Effective on Class A and B fires. Carried on the engines and rescue. This type of extinguisher has a special air aspirating nozzle. Contains 2 ½ gallons of water with the addition of foam concentrate. Excellent for use in covering a spill or small flammable liquid fires. May also be used on Class A fires. METL-X Effective on Class D fires only. Carried on the Rescue only. This type of extinguisher contains a specialized extinguishing agent for combustible metal fires such as magnesium or titanium. METL-X is a finely powdered sodium chloride (salt). METL-X is best applied gently to completely cover any burning metal. The burning metal should be covered and not disturbed until extinguishment is complete. Vehicle Fires Assume a blocking position unless situation dictates otherwise due to traffic or uphill / upwind considerations Officer chocks involved vehicle wheels Minimum 1 ¾ line with fire showing Avoid the bumper areas, attack from corners or sides. Deploy and man a dry chemical extinguisher for flammable liquid fires. Deploy porto power spreader and halligan for vehicle engine compartment access. Safe batteries Inspect trunk / cargo area 21

22 Highway Incident Hazard Control The engine is responsible for: Establishing scene safety in a blocking mode. Initial stabilization of the vehicle if arriving before the Rescue. Hazard control including: o Check for / control fuel leaks o Disconnect vehicle battery o Standing by with fire extinguisher for motor vehicle accidents o Standing by with a charged hose line and extinguisher during extrications. Utility Incidents Electrical Downed wires Position apparatus 2 pole spans from the incident. Establish a safe area and deny access. Coordinate actions with Police. Downed wires with no arcing or burning is a traffic control incident. Notify the utility Provide the address and closest pole number. Do not approach or touch wires. Pole top fires await arrival of utility and support firefighting efforts Wires arcing in trees with no damage generally do not require FD intervention. Confirmed Gas Leak Inside Leak Notify Gas Company Locate gas meter Monitor with O2/LEL meter Stop leak locally (valve to stove, heater, etc) if possible Secure meter if necessary Secure leak and danger tag valve Ventilate Uncontrollable Inside Leak Structure Fire Assignment Water Supply Evacuate Gas Company 22

23 Outside Leak Notify Gas Company Isolate area and deny entry Secure potential ignition sources Monitor for high flammable gas concentrations in area and surrounding structures Depending on severity and exposures: o Consider a structure fire assignment o Water Supply o Evacuation Confirmed Carbon Monoxide Incidents Interview occupants for signs / symptoms Monitor with house closed up and appliances running. Use SCBA. Attempt to locate faulty appliances, plugged flue or chimney. Notify Gas Company Secure appliances Ventilate EMS First Responder Operations The engine companies are the primary EMS response vehicles. Each engine is equipped with: A jump bag for trauma and basic medical emergencies. Semi automatic defibrillator Suction unit Airway bag (oral and nasal airways, bag valve masks) Long board and head blocks The primary goal of the EMS first responder program is to respond to ALS level calls and provide care when an ambulance is not readily available. The EMS engine is also dispatched for all calls involving major trauma and patients reported in cardiac or respiratory arrest. 23

24 When arriving before the ambulance or medic unit, the firefighter first responder or EMT should take control of patient care, gathering information and ensuring basic life support is provided. On arrival of the Squad or Medics, the firefighter will provide a complete turnover on information gathered and care provided up to that point. The remaining members of the engine company should assist EMS as required in treatment, packaging and transport of the patient. Mass / Emergency Decontamination Operations Both engines can be equipped to provide mass decontamination as necessary. An area for the decon corridor should be selected that provides: Containment of victims Containment of run off A water supply Victim privacy Mass decon is provided using flooding quantities of water at low pressure (pressure should not exceed 40 psi. The engines should be set up so that they are side by side with water supplies to the OUTSIDE of the corridor. The engines should be apart. The pump operator installs the spare 30 degree adapters (L-1) on the pump panel to the inside of the corridor. They should be installed to counter the existing angle and provide for a slightly upward stream. 1 ½ caps are placed on the angle adapters and fog nozzles are provided opened and set on a medium to wide fog. The deck gun may be used with the pipe extension and a fog nozzle. The front bumper line of one engine can be used out in front to provide an initial wash down. Firefighters manning decon should be in full PPE and SCBA or utilize SCBA and the chemical protective clothing (CPC) kit. The decon corridor should delineated with traffic cones and specific instructions provided via PA to the victims. The victims should be instructed to proceed to the corridor Prior to reaching the decon streams instructions should be provided to remove valuables and bag or place on ground As victims approach streams they should be encouraged to wash fully and strip to their underwear. Victims should be directed to turn and ensure their head, face and hands in particular are fully flushed. As victims proceed through they should be turned over to EMS or Haz Mat for definitive decon. 24

25 Pump Operators Reference Page Friction Loss Table (per 100 of hose) GPM Hose 1 ¾ ½ NOZZLE PRESSURE* Handline GALLONS PER MINUTE (GPM) SOLID BORE NOZZLES SOLID BORE DIAMETER (INCHES) POUNDS REACTION FORCE (RF) 3/8" 1/2" 5/8" 3/4" 7/8" 15/16" 1" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 2" Master Stream g g g g g g g g g 25

26 26

Firefighter Review. Instructor Guide

Firefighter Review. Instructor Guide Firefighter Review Instructor Guide Session Reference: 3 Topic: Attack Line Handling Level of Instruction: Time Required: Three Hours Materials: Two Fully Equipped Pumpers Structure for Use in Advancing

More information

Operating, Installation, and Maintenance Instructions

Operating, Installation, and Maintenance Instructions ELKHART BRASS MFG. CO., INC. 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 Operating, Installation, and Maintenance Instructions RAM Personal Portable Monitor

More information

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM ENGINE COMPANY SKILLS 1 ¾ RESIDENTIAL ATTACK LINES

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM ENGINE COMPANY SKILLS 1 ¾ RESIDENTIAL ATTACK LINES 3 ENGINE COMPANY SKILLS 1 ¾ RESIDENTIAL ATTACK LINES 1. General Information The attack line of choice for a residential fire is the pre-connected 1 ¾ attack line with an Automatic Nozzle 1 ¾ attack lines

More information

Lebanon Fire Department Lebanon Engine 512 Check Sheet

Lebanon Fire Department Lebanon Engine 512 Check Sheet Page 1 of 8 Initials Engine Oil Transmission Fluid Windshield washer fluid Radiator level Power Steering Fluid Mileage (All digits) Brakes/Air Tanks Fuel Level Windshield Wipers Brake Lights Interior Lights

More information

PRE-DESIGNATED DISPATCHING. Presented by The MCCC ROG Committee

PRE-DESIGNATED DISPATCHING. Presented by The MCCC ROG Committee PRE-DESIGNATED DISPATCHING Presented by The MCCC ROG Committee Overview Projected Dispatch Change Current CAD utilizes three Fire codes. Status is kept only on the first Officer that responds, arrives,

More information

How To Stop A Gas Leak

How To Stop A Gas Leak Natural Gas / Propane Emergencies Probationary Firefighter Academy Properties of Natural Gas / Propane Natural Gas and Propane are gaseous fossil fuels Natural Gas is primarily Methane(CH 4 ) Propane is

More information

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS Products Include: 60 gpm eductors Style 3060, 3061, 3062 & 3070 95 gpm eductors Style

More information

The In-Line Gauge in Standpipe Operations

The In-Line Gauge in Standpipe Operations The In-Line Gauge in Standpipe Operations BY RUSS CHAPMAN Your engine company receives a report of fire in a mid-rise elderly housing complex during morning coffee at the beginning of a shift. You know

More information

Natural Gas Emergencies

Natural Gas Emergencies Natural Gas Emergencies Purpose To protect the personnel within the department, and citizens from the hazards involved in a natural gas emergency. The Incident Commander is to use his/her best judgment

More information

Define Fire Stream. A stream of water, or other extinguishing agent, after it leaves the fire hose and nozzle until it reaches the desired point

Define Fire Stream. A stream of water, or other extinguishing agent, after it leaves the fire hose and nozzle until it reaches the desired point Nozzles and Streams Define Fire Stream A stream of water, or other extinguishing agent, after it leaves the fire hose and nozzle until it reaches the desired point Identify the Purposes of a Fire Stream

More information

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS 1.0 PURPOSE 1.1 To provide an overview of fire extinguisher use

More information

FIRE,FIREFIGHTING & FIREFIGHTING EQUIPMENT

FIRE,FIREFIGHTING & FIREFIGHTING EQUIPMENT FIRE,FIREFIGHTING & FIREFIGHTING EQUIPMENT 1 1. Elements of Fire: The process combustion of fire may be regarded as a chemical triangle in its three side consisting of fuel, heat and oxygen. The control

More information

FIREFIGHTER SAFETY. Stay safe during substation fires

FIREFIGHTER SAFETY. Stay safe during substation fires FIREFIGHTER SAFETY Stay safe during substation fires FIREFIGHTERS AND SUBSTATIONS Electrical substations reduce the high voltages used to move electricity over long distances to the lower voltages that

More information

I. Introduction. 10 minutes

I. Introduction. 10 minutes I. Introduction 10 minutes Introduction (1 of 2) An uninterrupted water supply is: The primary weapon for extinguishment Essential for fire fighter safety Ensuring a dependable water supply is a critical

More information

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007 TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES 301.010 ANNUAL SERVICE TEST FOR FIRE HOSE EFFECTIVE: OCTOBER 2007 The Department will test all fire hose annually. The testing of fire hose determines its serviceability.

More information

FIRE PREVENTION PLAN

FIRE PREVENTION PLAN FIRE PREVENTION PLAN 1 FIRE PREVENTION PLAN OSHA s Fire Prevention Plan regulation, found at 29 CFR 1910.38(b) and 29 CFR 1926.24, requires Northern Clearing, Inc. to have a written fire prevention plan

More information

FIRE FIGHTER I CHARACTERISTICS AND FUNCTIONS OF WILDLAND HOSE LAYS TOPIC: TIME FRAME: 1:00. Level II LEVEL OF INSTRUCTION:

FIRE FIGHTER I CHARACTERISTICS AND FUNCTIONS OF WILDLAND HOSE LAYS TOPIC: TIME FRAME: 1:00. Level II LEVEL OF INSTRUCTION: TOPIC: CHARACTERISTICS AND FUNCTIONS OF WILDLAND HOSE LAYS TIME FRAME: 1:00 LEVEL OF INSTRUCTION: Level II AUTHORITY: 1997 NFPA 1001 3.3-18 BEHAVIORAL OBJECTIVE: Condition: Behavior: Standard: A written

More information

Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases

Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases VENTILATION Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases If a fire is contained in a building, the heat, smoke, and toxic gases will spread.

More information

NFPA Fire Fighter II

NFPA Fire Fighter II State of Oregon Department of Public Safety Standards and Training NFPA Fire Fighter II Task Book Task Book Assigned To: Name DPSST Fire Service # Department Name Date Initiated Signature of Department

More information

HAZARDS AND THREATS WILDFIRES HOMEOWNERS CHECKLIST INSIDE THE HOME

HAZARDS AND THREATS WILDFIRES HOMEOWNERS CHECKLIST INSIDE THE HOME HAZARDS AND THREATS WILDFIRES HOMEOWNERS CHECKLIST INSIDE THE HOME KITCHEN Keep a working extinguisher in the kitchen. Maintain electric and gas stoves in good operating condition. Keep baking soda on

More information

HELI-DECKS & HELI-PORTS

HELI-DECKS & HELI-PORTS 1 HELI-DECKS & HELI-PORTS GENERAL FOAM INFORMATION DESCRIPTION Helicopters provide a level of convenience that is probably unequaled by other forms of transport. While helicopters can land in the middle

More information

OREGON FIRE CODE Interpretations and Technical Advisories

OREGON FIRE CODE Interpretations and Technical Advisories OREGON FIRE CODE Interpretations and Technical Advisories A collaborative service by local and state fire professionals, along with our stakeholders and customers, to provide consistent and concise application

More information

Toms River Fire Academy

Toms River Fire Academy Pump School Manual Toms River Fire Academy Table of contents Chapter 1 Characteristics of Water Page 3 Pressures, Atmospheric, Static, Residual, Head.Page 7 Chapter 2 Pump Construction and Gauges Page

More information

PROBATIONARY FIREFIGHTER HANDBOOK

PROBATIONARY FIREFIGHTER HANDBOOK RED OAK FIRE RESCUE PROBATIONARY FIREFIGHTER HANDBOOK Red Oak Fire Rescue, Probationary Firefighter Handbook 1 TABLE OF CONTENTS 3. Program Intent 27. Salvage and Overhaul 4. Instructions and Reference

More information

TRAINING AND EQUIPMENT MANUAL 307 SALVAGE EQUIPMENT EFFECTIVE: OCTOBER 2007

TRAINING AND EQUIPMENT MANUAL 307 SALVAGE EQUIPMENT EFFECTIVE: OCTOBER 2007 TRAINING AND EQUIPMENT MANUAL 307 SALVAGE EQUIPMENT 307.001 HALLWAY RUNNERS, CARRYALLS, AND SALVAGE COVERS EFFECTIVE: OCTOBER 2007 PURPOSE The purpose of this document is to familiarize members about Department

More information

SOUTH LYON FIRE DEPARTMENT Manual of Procedures 404

SOUTH LYON FIRE DEPARTMENT Manual of Procedures 404 GENERAL STRUCTURAL FIRE FIGHTING Issued: February 6, 2011 Revised: March 6, 2015 Approved: Chief Mike Kennedy I. SCOPE The general structural firefighting procedure will provide guidelines to incident

More information

FIRE SAFETY HANDBOOK

FIRE SAFETY HANDBOOK 29 CFR 1960.20, Alternate Standard For Fire Safety In Airport Traffic Control Towers (ATCTs) Fire Prevention Plan (FPP) Emergency Action Plan (EAP) FIRE SAFETY HANDBOOK DEPARTMENT OF TRANSPORTATION FEDERAL

More information

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.

More information

Name Of Occupancy Date. Yes No Describe

Name Of Occupancy Date. Yes No Describe FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address

More information

Current as of 11/10/08 1 of 1

Current as of 11/10/08 1 of 1 BEST PRACTICES STANDARDS FOR SCHOOLS UNDER CONSTRUCTION OR BEING PLANNED FOR CONSTRUCTION I. Site Layout A. School buildings shall be provided with a securable perimeter. A securable perimeter means that

More information

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations; (1979) (Rev.1 1990) (Rev.2 1996) (Rev.3 Jan 2012) Safety features.1 Fire protection and extinction.1.1 General Fire protection arrangements and fire extinguishing systems are to be in accordance with the

More information

Based on the initial size-up and any information available, Command will formulate an action plan to deal with the situation.

Based on the initial size-up and any information available, Command will formulate an action plan to deal with the situation. Hazardous Materials Response Clear Creek Fire Authority This plan provides a basic philosophy and strategic plan for hazardous materials situations. All Clear Creek Fire policies and procedures, unless

More information

Town of Bellingham Fire Department

Town of Bellingham Fire Department Town of Bellingham Fire Department OFFICE OF THE Fire Prevention Division Captain Robidoux- jrobidoux@bellinghamma.org Lieutenant Bangma- jbangma@bellinghamma.org Fire Safety Inspection Guidelines for

More information

Springdale Fire Department Backup Driver Certification Program. Behavioral Objectives

Springdale Fire Department Backup Driver Certification Program. Behavioral Objectives Springdale Fire Department Backup Driver Certification Program Backup Driver Task Book I. Obtain required prerequisites 1. Performance a. Complete Probationary Program b. Complete CEVO Fire Course c. Complete

More information

Fire Response Plan - Code Red

Fire Response Plan - Code Red Fire Response Plan - Code Red SUMMARY & PURPOSE The purpose of the Fire Response Plan Code Red is to provide guidelines for hospital personnel to follow during a Code Red. As more fully described below,

More information

SOUTH DAKOTA FIRE SERVICE TRAINING PRACTICAL SKILLS TEST

SOUTH DAKOTA FIRE SERVICE TRAINING PRACTICAL SKILLS TEST SOUTH DAKOTA FIRE SERVICE TRAINING PRACTICAL SKILLS TEST FIREFIGHTER NAME: DATE: Practical Skills Test eligibility : A firefighter is eligible to take the Practical Skills Test ONLY if he/she is eighteen

More information

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result

More information

FIRE EXTINGUISHER TRAINING

FIRE EXTINGUISHER TRAINING FIRE EXTINGUISHER TRAINING Fire safety, at its most basic, is based upon the principle of keeping fuel sources and ignition sources separate. Three things must be present at the same time to produce fire:

More information

Class A Foam Mixing and Application Equipment

Class A Foam Mixing and Application Equipment Class A Foam Mixing and Application Equipment Adding Phos-Chek Class A foam concentrate to water: There are many methods of adding Phos-Chek Class A foam concentrate to water. The different methods have

More information

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to

More information

Section 14. Forklift Safety Contents 14.1 Operator Safety

Section 14. Forklift Safety Contents 14.1 Operator Safety Section 14. Forklift Safety Contents 14.1 Operator Safety... 14-1 14.2 Inspection and Maintenance... 14-2 14.3 Handling the Load... 14-3 14.4 Fueling Liquefied Petroleum (LP) Gas Forklifts... 14-3 14.5

More information

Tank Farm and Bulk Storage Fire Incidents

Tank Farm and Bulk Storage Fire Incidents Instructor Manual Module 7 Tank Farm and Bulk Storage Fire Incidents Module Objective Upon the successful completion of this module, participants will be able to develop plans to fight or contain fires

More information

Warehouse Checklist. Warehouse Construction

Warehouse Checklist. Warehouse Construction PAGE 1 Warehouse Checklist Recent NFPA statistics estimate that in 1998 approximately 36,000 fires occurred in structures used for storage, accounting for $687mm of damage (over 10% of total fire damage

More information

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or

More information

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief Dennis Fire Department Fire Prevention Mark Dellner Fire Chief FIRE SAFETY INSPECTION GUIDELINES FOR COMMERCIAL PROPERTIES (MA Fire Prevention Regulations 527 CMR, MGL Chapter 148) FIRE PREVENTION CHECKLIST-

More information

Fire Extinguishers. A Health and Safety Guideline for Your Workplace. Fire Extinguishing Methods. Introduction. Types of Extinguishers

Fire Extinguishers. A Health and Safety Guideline for Your Workplace. Fire Extinguishing Methods. Introduction. Types of Extinguishers A Health and Safety Guideline for Your Workplace Introduction Fire extinguishers are designed to put out or control small fires. A small fire, if not checked immediately, will soon spread out of control.

More information

Walking and Working Surface Checklist:

Walking and Working Surface Checklist: Walking and Working Surfaces Purpose: This information is presented to improve the level of safety in our operations, and to inform you that we will comply with the OSHA Standard 29 CFR 1910.23. Responsibility:

More information

2010 Residential Water Heater Replacement Check List

2010 Residential Water Heater Replacement Check List 2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This

More information

T r a i n i n g T a b l e t

T r a i n i n g T a b l e t V o l u m e 3, I s s u e 3 M a r c h, 2 0 1 3 QRS calls: When do I make a QRS report? Recently we were asked to clarify how to decide if a QRS report should be entered into the Firehouse Software. In a

More information

MOTOR FUEL DISPENSING SAFETY

MOTOR FUEL DISPENSING SAFETY STRATEGIC OUTCOMES PRACTICE TECHNICAL ADVISORY BULLETIN January 2010 MOTOR FUEL DISPENSING SAFETY Fire! Not an alarm anyone wants to hear, especially not when the fire is burning at a major fuel source.

More information

Fire Pump Plan Review March 2010

Fire Pump Plan Review March 2010 Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business

More information

800-424-1716. A global leader in: Garner Environmental Services: www.garner-es.com. Garner Decontamination Solutions: www.garner-ds.

800-424-1716. A global leader in: Garner Environmental Services: www.garner-es.com. Garner Decontamination Solutions: www.garner-ds. 800-424-1716 A global leader in: Emergency Response Disaster Response Biological Decontamination Industrial Services Training & Rescue Health & Safety Garner Environmental Services: www.garner-es.com Garner

More information

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use. Walmart Standards for Suppliers Section 7. Health and Safety 7. Health and Safety Suppliers must provide workers with a safe and healthy work environment. Suppliers must take proactive measures to prevent

More information

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29CFR1910.36-29CFR1910.38-29CFR1910.157-29CFR1910.165 NFPA-10 BASIS: The OSHA Emergency Action Planning and the

More information

FIRE SAFETY FOR OFFICE WORKERS

FIRE SAFETY FOR OFFICE WORKERS FIRE SAFETY FOR OFFICE WORKERS This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of the program and the subject

More information

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS In this document are the fire safety equipment maintenance requirements that are found in Division B of the Alberta Fire Code (AFC 2006) for

More information

Fire Safety Risk Assessment Checklist for Residential Care Premises

Fire Safety Risk Assessment Checklist for Residential Care Premises Checklist for Residential Care Premises Name of Premises: Address of Premises: Name of Responsible Person: What area / location does the assessment cover? Does the assessment cover the whole site YES or

More information

OFFICER CANIDATE SCHOOL. QAS Project El Dorado Furniture Store 441/Southern Blvd

OFFICER CANIDATE SCHOOL. QAS Project El Dorado Furniture Store 441/Southern Blvd OFFICER CANIDATE SCHOOL QAS Project El Dorado Furniture Store 441/Southern Blvd Presenters John Flaherty Operational Lt Trevor Harris Operational Lt Donald Corbitt Operational Lt Lawrence Wolfe Operational

More information

Commercial Fire Inspections

Commercial Fire Inspections Commercial Fire Inspections Fire Department Inspection Requests and Procedures The following guidelines shall be used when calling for inspection requests: 1. All inspection requests shall be coordinated

More information

ESCAMBIA COUNTY FIRE-RESCUE 3105.005

ESCAMBIA COUNTY FIRE-RESCUE 3105.005 Patrick T Grace, Fire Chief Page 1 of 13 PURPOSE: Escambia County Fire-Rescue responds to a wide range of emergency incidents. In order to effectively manage personnel and resources and to provide for

More information

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

ELECTRIC/DIESEL FIRE PUMP CHECK LIST BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested

More information

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE Sec. 58.1. Division D-O occupancies. 58.2. Separation and mixed occupancy. OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM

More information

Automatic Fire Sprinkler Submittal Requirements

Automatic Fire Sprinkler Submittal Requirements Automatic Fire Sprinkler Submittal Requirements All commercial and industrial buildings with a total floor area of 5000 sq. ft. shall have an approved automatic sprinkler system installed. The Windsor-Severance

More information

Spray Booth Guideline

Spray Booth Guideline Department of Development Service 135 North D Street, Perris CA. 92570 Phone: (951) 443-1029 Fax: (951) 943-3293 PURPOSE The intent of this guideline is to provide the information necessary to ensure that

More information

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT INTRODUCTION No matter how reliable fire protection equipment may seem, periodic maintenance is needed to ensure proper operation. Fire protection

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Important Ontario Fire Code Information for Building Owners in the City of Windsor Important Ontario Fire Code Information for Building Owners in the City of Windsor This information is intended to be used a reference only. For a complete listing consult the Ontario Fire Code or contact

More information

Series 90 Portable Capstan Hoist. Owners Manual ! CAUTION

Series 90 Portable Capstan Hoist. Owners Manual ! CAUTION Series 90 Portable Capstan Hoist Owners Manual! CAUTION The equipment covered in this document should be installed, used, and serviced only by competent personnel familiar with and following good work

More information

1402 Hybrid Firefighter I. Course Orientation Guide (Rev 1)

1402 Hybrid Firefighter I. Course Orientation Guide (Rev 1) 1402 Hybrid Firefighter I Course Orientation Guide (Rev 1) Department of Labor, Licensing and Regulation Division of Fire and Life Safety South Carolina Fire Academy 2014 1402 Hybrid Firefighter I Course

More information

Introduction to and Operation of Compressed Air Foam Systems (CAFS)

Introduction to and Operation of Compressed Air Foam Systems (CAFS) Compressed Air Foam Systems (CAFS) Mesa Fire Department currently has nine (9) compressed air foam pumpers. Each unit has 20 to 30 gallons of Class A foam on board. Typical compressed air foam is available

More information

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems Vehicle Fire Protection An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems 002792 Off-road vehicles do have fires Statistics show that off-road vehicles burn with alarming frequency. These

More information

Directions to Students

Directions to Students ACTIVITY GUIDE 90 min. Small groups Needed: NAERG Guidebook NIOSH Pocket Guide Activity #4.1 Obtaining Hazardous Materials Information Student Instructions Purpose To allow the participants an opportunity

More information

Portable Fire Extinguisher Presentation

Portable Fire Extinguisher Presentation Slide 1 Fire Extinguisher Training A requirement of all Clemson University Employees as mandated by OSHA: Portable fire extinguishers. - 1910.157 Welcome to the Clemson University Online Fire Extinguisher

More information

Building Code Clarifications - 7. Fire Resistance

Building Code Clarifications - 7. Fire Resistance Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,

More information

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION Page No: 1 of 7 6.0 PURPOSE (192.751) All possible precautions shall be exercised to prevent the accidental escape and ignition of gas. Whenever possible, potential sources of ignition should be eliminated

More information

RESIDENTS FIRE SAFETY INFORMATION PACK

RESIDENTS FIRE SAFETY INFORMATION PACK RESIDENTS FIRE SAFETY INFORMATION PACK MARIE CURIE SCEAUX GARDENS ESTATE LONDON SE5 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information

More information

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600 OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done

More information

MEDICAL UNIVERSITY OF SOUTH CAROLINA DEPARTMENT OF PUBLIC SAFETY. of Prisoners

MEDICAL UNIVERSITY OF SOUTH CAROLINA DEPARTMENT OF PUBLIC SAFETY. of Prisoners MEDICAL UNIVERSITY OF SOUTH CAROLINA DEPARTMENT OF PUBLIC SAFETY SUBJECT: Searching and Transportation of Prisoners EFFECTIVE DATE: 1 January 1999 PAGE 1 OF 10 REVIEW DATE: 30 November 2015 APPROVED: CHANGE

More information

Arapahoe County Residential Water Heater Installation and Inspection Guide

Arapahoe County Residential Water Heater Installation and Inspection Guide Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however

More information

Winnipeg Fire Department Fire Prevention Branch

Winnipeg Fire Department Fire Prevention Branch Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of

More information

FIREFIGHTING AND DAMAGE CONTROL

FIREFIGHTING AND DAMAGE CONTROL FIREFIGHTING AND DAMAGE CONTROL Everyone on aboardship have another big job - to work aside from their primary duties. This big job is to look out constantly for the safety of the ship and crew. When the

More information

Minnesota State Department of Public Safety

Minnesota State Department of Public Safety Minnesota State Department of Public Safety 444 Cedar Street, Suite 145, St. Paul, Minnesota 55101-5145 Phone: 651/215-0500 FAX: 651/215-0525 TTY: 651/282/6555 Internet: http://www.fire.state.mn.us Inspection

More information

and Extinguisher Training

and Extinguisher Training RACES Field Operations Course -Unit 10 Fire Safety Awareness and Extinguisher Training Developed in cooperation with the National Fire Protection Association and the Public Information and Life Safety

More information

CHAPTER 9 FIRE PROTECTION SYSTEMS

CHAPTER 9 FIRE PROTECTION SYSTEMS CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 901 GENERAL 901.1 Scope. Provisions of this chapter shall govern the application, design, installation, testing and maintenance of automatic sprinklers, standpipes

More information

The following definitions apply with regard to requirements specified in this document:

The following definitions apply with regard to requirements specified in this document: GUIDELINES FOR INSTALLATION OF TEMPORARY AND PERMANENT ABOVEGROUND DIESEL FUEL TANKS FOR EMERGENCY AND STANDBY POWER SYSTEMS LOCATED OUTSIDE OF BUILDINGS For Use by Unidocs Member Agencies or where approved

More information

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable

More information

WATER SUPPLY PROCEDURES MANUAL MECHANICSVILLE VOLUNTEER FIRE DEPARTMENT

WATER SUPPLY PROCEDURES MANUAL MECHANICSVILLE VOLUNTEER FIRE DEPARTMENT WATER SUPPLY PROCEDURES MANUAL MECHANICSVILLE VOLUNTEER FIRE DEPARTMENT December 2003 1 FOREWORD The content of this document is the result of the recommendations made by Charles H. Donaldson during his

More information

General Fire Code Requirements Within Commercial Tenant Spaces

General Fire Code Requirements Within Commercial Tenant Spaces FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved;

More information

RESIDENTS FIRE SAFETY INFORMATION PACK

RESIDENTS FIRE SAFETY INFORMATION PACK RESIDENTS FIRE SAFETY INFORMATION PACK PERRONET HOUSE PRINCESS STREET LONDON SE1 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information

More information

Fire Apparatus Operator Aircraft Rescue and Fire Fighting

Fire Apparatus Operator Aircraft Rescue and Fire Fighting Fire Apparatus Operator Aircraft Rescue and Fire Fighting Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/ Operator Professional Qualifications, 2014 Edition. Alabama Fire College

More information

FIRE DEPARTMENT HYDRAULICS

FIRE DEPARTMENT HYDRAULICS FIRE DEPARTMENT HYDRAULICS BASIC CONCEPTS & FORMULAS WATER MEASUREMENTS 1 Cubic foot of water weighs 62.5 pounds 1 Cubic foot of water contains 1,728 cubic inches 1 Cubic foot of water contains 7.5 gallons

More information

Powered Industrial Truck Safety Program

Powered Industrial Truck Safety Program Powered Industrial Truck Safety Program TABLE OF CONTENTS Forklift Safety Program 1.0 Overview... 3 2.0 Policy.....3 3.0 Requirements 3 4.0 Purpose. 3 5.0 Scope......4 6.0 Forklift Procedures 4 6.0 Responsibilities.....6

More information

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS

More information

RESIDENTS FIRE SAFETY INFORMATION PACK

RESIDENTS FIRE SAFETY INFORMATION PACK RESIDENTS FIRE SAFETY INFORMATION PACK CASTLEMEAD CAMBERWELL ROAD LONDON SE5 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information

More information

Dry Chemical Systems TWIN AGENT CAPABILITY

Dry Chemical Systems TWIN AGENT CAPABILITY Dry Chemical Systems The following data is based on maximum anticipated area of spill or contained area of hazard and the fire fighters being experienced professionals. If the fire fighter is a novice,

More information

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or comments regarding the

More information

SUPERYACHT SPARES. Nozzles and portable monitors. www.superyachtspares.com / info@superyachtspares.com / +31 183 639193

SUPERYACHT SPARES. Nozzles and portable monitors. www.superyachtspares.com / info@superyachtspares.com / +31 183 639193 Nozzles and portable monitors Rosenbauer - Nozzles and portable monitors EN Maximum extinguishing effect. Minimal water consumption. The Rosenbauer nozzle enables the manual adjustment of the water flow

More information