1 Technical Documentation Wind Turbine Generator Systems GE 1.5s/se - 50 Hz & 60 Hz GE imagination at work

2 Gepower.com Visit us at All technical data is subject to change in line with ongoing technical development. Information about copyright and patent rights This document is to be treated confidentially. It may only be made accessible to authorized persons. It may only be made available to third parties with the expressed written consent of GE Wind Energy GmbH. All documents are copyrighted within the meaning of the Copyright Act. The transmission and reproduction of the documents, also in extracts, as well as the exploitation and communication of the contents are not allowed without express written consent. Contraventions are liable to prosecution and compensation for damage. We reserve all rights for the exercise of commercial patent rights. GE imagination at work 1.5s_PCD_allComp_xxxxxxxx.ENxx.10a.doc

3 Table of Contents 1 GE 1.5s/se - 50 Hz and 60 Hz, HH 64.7 m GE 1.5se - 50 Hz and 60 Hz, HH < 64.7 m Validity Cut-Out and Re-Cut-In Wind Speeds GE 1.5s with WZ II Tower GE 1.5s and 1.5se (with IEC TC II / WZ III tower for 1.5s and with IEC I tower for 1.5se) with Bachmann Controller s_PCD_allComp_xxxxxxxx.ENxx.10a.doc

4

5 1 GE 1.5s/se - 50 Hz and 60 Hz, HH 64.7 m (Cut-out wind speed based on 10 minutes average) Rotor Diameter: 70.5 m Hub Heights: 64.7 m / 80 m** / 85 m** / 100 m* Wind Speed at HH [m/s] Electrical Power [kw] Cp.e *** 1500*** 0.05*** 23.5*** 1500*** 0.05*** 24.0*** 1500*** 0.05*** 24.5*** 1500*** 0.04*** 25.0*** 1500*** 0.04*** Table 1: Calculated power curve GE 1.5s/se 50 Hz & 60 Hz * only for WZ II configuration ** only for WZ III / IEC 2 configuration *** only for WZ III / IEC 2 and IEC 1 configuration 1.5s_PCD_allComp_xxxxxxxx.ENxx.10a.doc 5/9

6 6/9 1.5s_PCD_allComp_xxxxxxxx.ENxx.10a.doc

7 2 GE 1.5se - 50 Hz and 60 Hz, HH < 64.7 m (Cut-out wind speed based on 10 minutes average) Rotor Diameter: Hub Heights: 70.5 m 52.6 m and 54.7 m Wind Speed at HH [m/s] Electrical Power [kw] Cp.e *** *** *** *** *** Table 2: Calculated power curve GE 1.5s/se 50 Hz & 60 Hz 1.5s_PCD_allComp_xxxxxxxx.ENxx.10a.doc 7/9

8 8/9 1.5s_PCD_allComp_xxxxxxxx.ENxx.10a.doc

9 3 Validity The power curves apply under the following conditions: Turbulence of approx. 10 % to 15 % Standard atmosphere according to DIN ISO 2533, at mean sea level (Air density kg/m 3 ) The nominal power refers to the low-voltage side of the transformer. Information on the influences of the cold weather adaptations on the power curves can be found in the supplement to the technical description and specification "Cold Weather Adaptations". 4 Cut-Out and Re-Cut-In Wind Speeds 4.1 GE 1.5s with WZ II Tower If the average wind speed exceeds 22 m/s in a 600 s time interval 25 m/s in a 30 s time interval or 27 m/s in a 3 s time interval the wind turbine generator system will shut down. If the average wind speed remains below 19 m/s in a 300 s time interval the wind turbine generator system will cut in again. 4.2 GE 1.5s and 1.5se (with IEC TC II / WZ III tower for 1.5s and with IEC I tower for 1.5se) with Bachmann Controller If the average wind speed exceeds 25 m/s in a 600 s time interval 28 m/s in a 30 s time interval or 30 m/s in a 3 s time interval the wind turbine generator system will shut down. If the average wind speed remains below 22 m/s in a 300 s time interval the wind turbine generator system will cut in again. 1.5s_PCD_allComp_xxxxxxxx.ENxx.10a.doc 9/9

ENERCON WIND TURBINES

ENERCON WIND TURBINES Sales ENERCON GmbH Dreekamp 5 2665 Aurich Germany Phone +49 494192 7 Fax +49 4941 92 71 9 vertrieb@enercon.de E-33 E-44 E-48 E-53 E-7 E-82 ENERCON WIND TURBINES PRODUCT OVERVIEW ENERCON GmbH Dreekamp 5

More information

Excerpts from: Performance, Duration and Acoustic test reports for the Skystream 3.7 wind generator

Excerpts from: Performance, Duration and Acoustic test reports for the Skystream 3.7 wind generator Excerpts from: Performance, Duration and Acoustic test reports for the Skystream 3.7 wind generator Report One: Power performance measurement on the Skystream 3.7 according to IEC 61400-12-1 and BWEA Report

More information

Document number #12 DNS13006. Authors #20 Telephone: Date #40 AUGUST 2013

Document number #12 DNS13006. Authors #20 Telephone: Date #40 AUGUST 2013 #0 INSPECTION REPORT Discipline or report series #0 Inspection VESTAS wind turbines Title #5 VESTAS WIND TURBINE #2 Report number #52 #3 Authors #20 Telephone: Date #40 AUGUST 203 Summary #60 6 UNIT VESTAS

More information

GE Power & Water Renewable Energy. Digital Wind Farm THE NEXT EVOLUTION OF WIND ENERGY. www.ge.com/wind

GE Power & Water Renewable Energy. Digital Wind Farm THE NEXT EVOLUTION OF WIND ENERGY. www.ge.com/wind GE Power & Water Renewable Energy Digital Wind Farm THE NEXT EVOLUTION OF WIND ENERGY www.ge.com/wind GE S DIGITAL WIND FARM PITCH Since entering the wind industry in 2002, GE Power & Water s Renewable

More information

V52-850 kw The turbine that goes anywhere

V52-850 kw The turbine that goes anywhere V2-8 kw The turbine that goes anywhere Versatile, efficient, dependable and popular The highly efficient operation and flexible configuration of the V2 make this turbine an excellent choice for all kinds

More information

www.wind-power-program.com

www.wind-power-program.com This document has been downloaded from the library section of www.wind-power-program.com Visit our website for information on the WindPower program and the UK Wind Speed Database program both downloadable

More information

Siemens Wind Turbine SWT-2.3-108. The new productivity benchmark. www.siemens.com/wind

Siemens Wind Turbine SWT-2.3-108. The new productivity benchmark. www.siemens.com/wind Siemens Wind Turbine SWT-2.3-108 The new productivity benchmark www.siemens.com/wind The industry standard, redefined The Siemens 2.3-MW family has firmly established itself as the tried and tested workhorse

More information

PMDD WIND TURBINE 1.5MW

PMDD WIND TURBINE 1.5MW 1.5MW PMDD WIND TURBINE Generator Stator Rotor Blade Wind Measurement Equipment Casted Hub Auxiliary Crane Pitch System Base Frame Generator PM Rotor GOLDWIND 1.5MW PERMANENT MAGNET DIRECT-DRIVE (PMDD)

More information

Letter Report No. 100413407CRT-004 Project No. G100413407

Letter Report No. 100413407CRT-004 Project No. G100413407 3933 US Route 11 Cortland, NY 13045 Telephone: (607) 753-6711 Facsimile: (607) 753-1045 www.intertek.com Letter Report No. 100413407CRT-004 Project No. G100413407 Mr. Steve Turek Phone: 952-447-6064 Wind

More information

GE Renewable Energy. GE s 3 MW Platform POWERFUL AND EFFICIENT. www.ge.com/wind

GE Renewable Energy. GE s 3 MW Platform POWERFUL AND EFFICIENT. www.ge.com/wind GE Renewable Energy GE s 3 MW Platform POWERFUL AND EFFICIENT www.ge.com/wind GE S 3 MW PLATFORM PITCH Since entering the wind industry in 2002, GE Renewable Energy has invested more CONTROLS than $2 billion

More information

Nordex SE. Capital Markets Day Products & Sales - Lars Bondo Krogsgaard

Nordex SE. Capital Markets Day Products & Sales - Lars Bondo Krogsgaard Nordex SE Capital Markets Day Products & Sales - Lars Bondo Krogsgaard Rostock, 13 October 2011 SUMMARY The situation in the wind industry has changed: Attractive medium-term growth prospects Overcapacity

More information

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG DECIBEL - Main Result Calculation: 6 x V126 x HH150 Noise calculation model: ISO 9613-2 General Wind speed: 8,0 m/s Ground attenuation: General, Ground factor: 0,4 Meteorological coefficient, C0: 0,0 db

More information

BWEA Summary Report for the C&F Green Energy Small Wind Turbine, Model No. CF20 (Phase A)

BWEA Summary Report for the C&F Green Energy Small Wind Turbine, Model No. CF20 (Phase A) Cleeve Road, Leatherhead Surrey, KT22 7SB UK Telephone: +44 (0) 1372 370900 Facsimile: +44 (0) 1372 370999 www.intertek.com BWEA Summary Report for the C&F Green Energy Small Wind Turbine, Model No. CF20

More information

www.northernpower.com A wind turbine for Businesses, Schools and Farms

www.northernpower.com A wind turbine for Businesses, Schools and Farms www.northernpower.com A wind turbine for Businesses, Schools and Farms Direct. To Businesses, Schools and Farms Everywhere. Around the world, turbines are sprouting out of the ground, making wind one of

More information

Ewiiaapaayp Wind Project

Ewiiaapaayp Wind Project Ewiiaapaayp Wind Project Tony Pinto Ewiiaapaayp Members Tlingit Tantakwaan Teikweidi Yaan Yaan Eesh Development Process Site Selection topologically site specific Land Agreements federal approval uncertainties

More information

Databases. by David Cerda Salzmann

Databases. by David Cerda Salzmann Databases by David Cerda Salzmann In the previous lecture... What data you need What you use it for This hour: where to get data from Introduction OWT Design Procedure Fatigue Loads Extreme Loads Site-specific

More information

V66 1.75 MW & V66 2.0 MW (OFFSHORE)

V66 1.75 MW & V66 2.0 MW (OFFSHORE) V66 1.75 MW & V66 2. MW (OFFSHORE) with OptiTip and OptiSpeed Offshore and onshore There are two versions of the V66 turbine: a 2. MW model for offshore sites, and a 1.75 MW model for inland locations.

More information

DIRECT MATCHING TO GRID WITHOUT INVERTER VARIABLE PITCH. 20/24/30 mt TOWER WITH HYDRAULIC SYSTEM YAWING SYSTEM SAFETY LEVELS PLC CONTROL

DIRECT MATCHING TO GRID WITHOUT INVERTER VARIABLE PITCH. 20/24/30 mt TOWER WITH HYDRAULIC SYSTEM YAWING SYSTEM SAFETY LEVELS PLC CONTROL Wind turbine EW 50 Ergo Wind srl can boast of thirty years experience in the field of renewable energies as a producer of low environmental impact systems. The core business is represented by small wind

More information

GE Energy 1.5MW. Wind Turbine

GE Energy 1.5MW. Wind Turbine GE Energy 1.5MW Wind Turbine The industry workhorse The world needs a reliable, affordable and clean supply of electric power with zero greenhouse gas emissions, which is why GE continues to drive investment

More information

Northern Power 100. Community Wind Turbine for Businesses, Schools & Farms WWW.NORTHERNPOWER.COM

Northern Power 100. Community Wind Turbine for Businesses, Schools & Farms WWW.NORTHERNPOWER.COM Northern Power 100 Community Wind Turbine for Businesses, Schools & Farms WWW.NORTHERNPOWER.COM All turbines capture wind. The Northern Power 100 is designed to do it better. The right fit for your community

More information

Wind Resource Assessment for BETHEL, ALASKA Date last modified: 2/21/2006 Compiled by: Mia Devine

Wind Resource Assessment for BETHEL, ALASKA Date last modified: 2/21/2006 Compiled by: Mia Devine 813 W. Northern Lights Blvd. Anchorage, AK 99503 Phone: 907-269-3000 Fax: 907-269-3044 www.akenergyauthority.org Wind Resource Assessment for BETHEL, ALASKA Date last modified: 2/21/2006 Compiled by: Mia

More information

Siemens D7 platform 6.0-MW and 7.0-MW direct drive wind turbines. The new standard for offshore. siemens.com/wind

Siemens D7 platform 6.0-MW and 7.0-MW direct drive wind turbines. The new standard for offshore. siemens.com/wind Siemens D7 platform 6.0-MW and 7.0-MW direct drive wind turbines The new standard for offshore siemens.com/wind The first SWT-6.0-154 prototype Siemens, the offshore leader Intelligent ways to drive down

More information

V47-660 kw. Pitch regulated wind turbine with OptiTip and OptiSlip

V47-660 kw. Pitch regulated wind turbine with OptiTip and OptiSlip V47-660 kw Pitch regulated wind turbine with OptiTip and OptiSlip OptiSlip The V47-660 kw turbine features the unique generator principle OptiSlip, which allows both the rotor and the generator to vary

More information

Sound Power measurements according to IEC 61400-11

Sound Power measurements according to IEC 61400-11 Sound Power measurements according to IEC 61400-11 Siemens Wind Power All Rights Reserved 2011 Sound Power measurements according to IEC 61400-11 Tomas Hansen, Lars Enggaard email: trh@siemens.com Page

More information

Critical Limitations of Wind Turbine Power Curve Warranties

Critical Limitations of Wind Turbine Power Curve Warranties Critical Limitations of Wind Turbine Power Curve Warranties A. Albers Deutsche WindGuard Consulting GmbH, Oldenburger Straße 65, D-26316 Varel, Germany E-mail: a.albers@windguard.de, Tel: (++49) (0)4451/9515-15,

More information

NATIONAL INSTITUTE OF WIND ENERGY (NIWE)

NATIONAL INSTITUTE OF WIND ENERGY (NIWE) NATIONAL INSTITUTE OF WIND ENERGY (NIWE) Ref. : NIWE/S&C/RLMM/2014-15/95 Date : 09-01-2015 To All Concerned Dear Sir, Sub: Revised List of Models and Manufacturers of Wind Turbines - ADDENDUM I List to

More information

Power output of offshore wind farms in relation to atmospheric stability Laurens Alblas BSc

Power output of offshore wind farms in relation to atmospheric stability Laurens Alblas BSc Power output of offshore wind farms in relation to atmospheric stability Laurens Alblas BSc Photo: Vestas Wind Systems A/S 1 1. Introduction Background Atmospheric stability is known to influence wind

More information

Results of wake simulations at the Horns Rev I and Lillgrund wind farms using the modified Park model

Results of wake simulations at the Horns Rev I and Lillgrund wind farms using the modified Park model Downloaded from orbit.dtu.dk on: Feb 15, 216 Results of wake simulations at the Horns Rev I and Lillgrund wind farms using the modified Park model Pena Diaz, Alfredo; Réthoré, Pierre-Elouan; Hasager, Charlotte

More information

Wind turbine database: Modelling and analysis with focus on upscaling. Master s thesis in the Master programme Applied Mechanics

Wind turbine database: Modelling and analysis with focus on upscaling. Master s thesis in the Master programme Applied Mechanics Wind turbine database: Modelling and analysis with focus on upscaling Master s thesis in the Master programme Applied Mechanics JUAN PABLO SÁNCHEZ DE LARA GARCÍA Department of Applied Mechanics Division

More information

STATUS OF OFFSHORE WIND ENERGY DEVELOPMENT IN GERMANY

STATUS OF OFFSHORE WIND ENERGY DEVELOPMENT IN GERMANY On behalf of: Deutsche WindGuard GmbH - Oldenburger Straße 65-26316 Varel - Germany +49 (0)4451 9515-0 - info@windguard.de - www.windguard.com Additional [MW] Cumulative [MW] Cumulative (31.12.) Additions

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61400-2 Second edition 2006-03 Wind turbines Part 2: Design requirements for small wind turbines This English-language version is derived from the original bilingual publication

More information

WWD-1 1 MW wind turbine

WWD-1 1 MW wind turbine Appendix 10 Technical specification 1 (18) WWD-1 1 MW wind turbine Technical specification Appendix 10 Technical specification 2 (18) Contents 1. General... 3 2. Tower... 6 3. Rotor... 6 4. 3-RR main bearing

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Siemens D3 platform 3.0-MW, 3.2-MW, 3.3-MW, and 3.4-MW direct drive turbines. Reduced complexity, increased profitability. siemens.

Siemens D3 platform 3.0-MW, 3.2-MW, 3.3-MW, and 3.4-MW direct drive turbines. Reduced complexity, increased profitability. siemens. Siemens D3 platform 3.0-MW, 3.2-MW, 3.3-MW, and 3.4-MW direct drive turbines Reduced complexity, increased profitability siemens.com / wind As the major driver of innovation with more than 30 years of

More information

Sweden s leading manufacturer of small-scale wind power stations!

Sweden s leading manufacturer of small-scale wind power stations! Sweden s leading manufacturer of small-scale wind power stations! Product Information Table of content Content The company, its activities, vision and business concept. Product overview. Technology & security.

More information

GE Energy Wind Technology and Windfarm Overview

GE Energy Wind Technology and Windfarm Overview GE Energy Wind Technology and Windfarm Overview Forum on Renewable Energy Development in Myanmar November 1, 2012 saumil.shah@ge.com Topics for discussion Introduction to Wind Power technology Windfarm

More information

2.1MW PLATFORM Generations ahead

2.1MW PLATFORM Generations ahead 2.1MW PLATFORM Generations ahead WORLD S FIRST AND TALLEST LATTICE-TUBULAR HYBRID TOWER Innovative 120 meter hybrid tower with lattice structure at the base & tubular upper section Increased hub height

More information

V112-3.0 MW. Your best option for low cost energy production at low and medium wind sites. Federico Gonzalez Vives. Director Technology.

V112-3.0 MW. Your best option for low cost energy production at low and medium wind sites. Federico Gonzalez Vives. Director Technology. V112-3.0 MW Your best option for low cost energy production at low and medium wind sites Federico Gonzalez Vives. Director Technology. Vestas MED REOLTEC. Jornadas tecnicas 17 de junio de 2010 vestas.com

More information

INFLUENCES OF VERTICAL WIND PROFILES ON POWER PERFORMANCE MEASUREMENTS

INFLUENCES OF VERTICAL WIND PROFILES ON POWER PERFORMANCE MEASUREMENTS Abstract INFLUENCES OF VERTICAL WIND PROFILES ON POWER PERFORMANCE MEASUREMENTS U. Bunse, H. Mellinghoff DEWI GmbH, Ebertstr. 96, D 26382 Wilhelmshaven e mail: u.bunse@dewi.de The IEC 61400 12 1 [1] and

More information

GE Renewable Energy. Digital Wind Farm THE NEXT EVOLUTION OF WIND ENERGY. www.ge.com/wind

GE Renewable Energy. Digital Wind Farm THE NEXT EVOLUTION OF WIND ENERGY. www.ge.com/wind GE Renewable Energy Digital Wind Farm THE NEXT EVOLUTION OF WIND ENERGY www.ge.com/wind GE S DIGITAL WIND FARM PITCH Since entering the wind industry in 2002, GE Renewable Energy has invested more than

More information

Case Study 5 Use of Wind Turbine Technology

Case Study 5 Use of Wind Turbine Technology Case Study 5 Use of Wind Turbine Technology 1. Context Hong Kong relies on an adequate and reliable electricity supply for its economic development. Our electricity needs are met by the two electricity

More information

Bijlagen. Bijlage F. Slagschaduw

Bijlagen. Bijlage F. Slagschaduw Bijlagen Bijlage F. Slagschaduw 53 SHADOW - Main Result Calculation: Enercon E92 Assumptions for shadow calculations Maximum distance for influence Calculate only when more than 20 % of sun is covered

More information

Wind Turbine Technology Overview

Wind Turbine Technology Overview Wind Turbine Technology Overview Course No: M01-009 Credit: 1 PDH Brian McCaffrey, P.E. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877)

More information

Title: IEC WT 01 vs. IEC 61400-22 Development of a new standard and innovations in certification of Wind Turbines. mike.woebbeking@gl-group.

Title: IEC WT 01 vs. IEC 61400-22 Development of a new standard and innovations in certification of Wind Turbines. mike.woebbeking@gl-group. Title: IEC WT 01 vs. IEC 61400-22 Development of a new standard and innovations in certification of Wind Turbines Author: Address: Mike Woebbeking Germanischer Lloyd Industrial Services GmbH, Business

More information

QUALITY OF WIND POWER. How does quality affect the cost of electricity generation from wind power?

QUALITY OF WIND POWER. How does quality affect the cost of electricity generation from wind power? QUALITY OF WIND POWER How does quality affect the cost of electricity generation from wind power? QUALITY OF WIND POWER Wind power is a cornerstone in the green transition of the power sector, and onshore

More information

CFD SIMULATIONS OF WAKE EFFECTS AT THE ALPHA VENTUS OFFSHORE WIND FARM

CFD SIMULATIONS OF WAKE EFFECTS AT THE ALPHA VENTUS OFFSHORE WIND FARM CFD SIMULATIONS OF WAKE EFFECTS AT THE ALPHA VENTUS OFFSHORE WIND FARM Annette Westerhellweg, Thomas Neumann DEWI GmbH, Ebertstr. 96, 26382 Wilhelmshaven, Germany Phone: +49 (0)4421 4808-828 Fax: +49 (0)4421

More information

N60/1300 KW. Nordex N60 Long-term experience all over the world.

N60/1300 KW. Nordex N60 Long-term experience all over the world. N60/1300 KW Nordex N60 Long-term experience all over the world. 02_03 N60/1300 kw Visualisation of a turbine in the NC2-control system. THE N60/1300 KW: ROBUST, COMPACT AND INTERNATIONALLY WELL-TESTED.

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61400-1 Second edition 1999-02 Wind turbine generator systems Part 1: Safety requirements Aérogénérateurs Partie 1: Spécifications de sécurité IEC 1999 Copyright - all rights

More information

EFFECTS OF COMPLEX WIND REGIMES ON TURBINE PERFORMANCE

EFFECTS OF COMPLEX WIND REGIMES ON TURBINE PERFORMANCE EFFECTS OF COMPLEX WIND REGIMES ON TURBINE PERFORMANCE Elisabeth Rareshide, Andrew Tindal 1, Clint Johnson, AnneMarie Graves, Erin Simpson, James Bleeg, Tracey Harris, Danny Schoborg Garrad Hassan America,

More information

Libellula 50/55 kw WIND TURBINE TECHNICAL DESCRIPTION

Libellula 50/55 kw WIND TURBINE TECHNICAL DESCRIPTION Sede legale: Via Giuseppe Garibaldi 63, 59100 Prato P.IVA 02110810971 Sede operativa: Via del Mandorlo 30, 59100 Prato tel. (+39) 0574 550493 fax (+39) 0574 577854 - produzione@aria-srl.it Ufficio Commerciale:

More information

WindPRO version 2.9.285 Sep 2014 Printed/Page 2015-03-17 10:30 / 1. DECIBEL - Main Result Calculation: Wariant I wie a 90 m. Calculation Results

WindPRO version 2.9.285 Sep 2014 Printed/Page 2015-03-17 10:30 / 1. DECIBEL - Main Result Calculation: Wariant I wie a 90 m. Calculation Results Project: DECIBEL - Main Result Calculation: Wariant I wie a 90 m Noise calculation model: ISO 9613-2 Poland Wind speed: 10,0 m/s Ground attenuation: Alternative Meteorological coefficient, C0: 0,0 db Type

More information

Bijlage 4: In- en output slagschaduwonderzoek

Bijlage 4: In- en output slagschaduwonderzoek Bijlage 4: In- en output slagschaduwonderzoek SHADOW - Main Result Calculation: Slagschaduwonderzoek voor Windturbine Winvast E-82 Assumptions for shadow calculations Maximum distance for influence Calculate

More information

Wind Electrolysis: Hydrogen Cost Optimization

Wind Electrolysis: Hydrogen Cost Optimization Wind Electrolysis: Hydrogen Cost Optimization Genevieve Saur and Todd Ramsden NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by

More information

London Array Off-Shore Wind Farm

London Array Off-Shore Wind Farm London Array Off-Shore Wind Farm 1 Jamie R Mathlin Construction Manager Off-Shore Sub-Stations Project Commissioning Manager 27 Years Experience in the Power Industry Grid Trained Electrical Engineer 10

More information

ENERGY YIELD ASSESSMENT

ENERGY YIELD ASSESSMENT Module 2.4-2 ENERGY YIELD ASSESSMENT Gerhard J. Gerdes Workshop on Renewable Energies November 14-25, 25 Nadi, Republic of the Fiji Islands Contents power curve of wind turbine and international regulations

More information

V112-3.0 MW Making wind even more profitable

V112-3.0 MW Making wind even more profitable V112-3.0 MW Making wind even more profitable Large rotor diameter expands your opportunities The impressive 54.65 m blades set completely new standards, making it possible to produce more energy from the

More information

Haliade 150-6MW Experiencia funcional con la nueva generación offshore

Haliade 150-6MW Experiencia funcional con la nueva generación offshore Haliade 150-6MW Experiencia funcional con la nueva generación offshore Bilbao Marine Energy week 2013 Daniel Castell, Offshore Wind Platform Director 17/04/2013 Alstom Group Three main activities in four

More information

The BASIS module in WindPRO is necessary for the use of any of the other calculation modules. It contains the four following elements:

The BASIS module in WindPRO is necessary for the use of any of the other calculation modules. It contains the four following elements: The BASIS module in WindPRO is necessary for the use of any of the other calculation modules. It contains the four following elements: 1. Project Management / Globe (Project Explorer) 2. WTG Catalogue

More information

Manufactured by Seaforth Energy. The world s most proven 50 kw wind turbine

Manufactured by Seaforth Energy. The world s most proven 50 kw wind turbine Manufactured by Seaforth Energy The world s most proven 50 kw wind turbine The world s most proven 50 kw wind turbine The AOC 15/50 is the world s most proven 50 kw wind turbine. Manufactured by Seaforth

More information

The DTU 10-MW Reference Wind Turbine

The DTU 10-MW Reference Wind Turbine Downloaded from orbit.dtu.dk on: Nov 22, 2015 The DTU 10-MW Reference Wind Turbine Bak, Christian; Zahle, Frederik; Bitsche, Robert; Kim, Taeseong; Yde, Anders; Henriksen, Lars Christian; Hansen, Morten

More information

Integrating WAsP and GIS Tools for Establishing Best Positions for Wind Turbines in South Iraq

Integrating WAsP and GIS Tools for Establishing Best Positions for Wind Turbines in South Iraq Integrating WAsP and GIS Tools for Establishing Best Positions for Wind Turbines in South Iraq S.M. Ali Remote Sensing Research Unit, College of Science, Univ. of Baghdad, Baghdad, Iraq deanoffice {at}

More information

As a minimum, the report must include the following sections in the given sequence:

As a minimum, the report must include the following sections in the given sequence: 5.2 Limits for Wind Generators and Transformer Substations In cases where the noise impact at a Point of Reception is composed of combined contributions due to the Transformer Substation as well as the

More information

ort Interval Data Logging Microgeneration Monitoring and Control JASON LONG A. DONNELLAN T. O BRIEN

ort Interval Data Logging Microgeneration Monitoring and Control JASON LONG A. DONNELLAN T. O BRIEN ort Interval Data Logging Embedded System For Microgeneration Monitoring and Control JASON LONG A. DONNELLAN T. O BRIEN Motivation Investigate turbine under-performance Accurately create a wind profile

More information

Some scientific challenges in aerodynamics for wind turbines

Some scientific challenges in aerodynamics for wind turbines Some scientific challenges in aerodynamics for wind turbines Christian Bak Senior Scientist Team Leader: Aerodynamics, aeroacoustics, airfoil and blade design Technical University of Denmark DTU Wind Energy

More information

How Noise is Generated by Wind Turbines The mechanisms of noise generation. Malcolm Hayes Hayes McKenzie Partnership Ltd Machynlleth & Salisbury

How Noise is Generated by Wind Turbines The mechanisms of noise generation. Malcolm Hayes Hayes McKenzie Partnership Ltd Machynlleth & Salisbury How Noise is Generated by Wind Turbines The mechanisms of noise generation Malcolm Hayes Hayes McKenzie Partnership Ltd Machynlleth & Salisbury Overview Main sources of noise from wind turbines Causes

More information

Financing Community Wind

Financing Community Wind Financing Community Wind Wind Data and Due Diligence What is the Project's Capacity Factor? Community Wind Energy 2006 March 8, 2006 Mark Ahlstrom mark@windlogics.com Slide 1 The Need for Wind Assessment

More information

THE NEW GUIDELINE FOR THE CERTIFICATION OF WIND TURBINES, EDITION 2010

THE NEW GUIDELINE FOR THE CERTIFICATION OF WIND TURBINES, EDITION 2010 THE NEW GUIDELINE FOR THE CERTIFICATION OF WIND TURBINES, EDITION 2010 Mike Woebbeking Germanischer Lloyd Industrial Services GmbH, Renewables Certification (GL) Brooktorkai 18, 20457 Hamburg, GERMANY

More information

Norman Wells Wind Energy Pre-feasibility Analysis Summary

Norman Wells Wind Energy Pre-feasibility Analysis Summary Norman Wells Wind Energy Pre-feasibility Analysis Summary Summary of Wind Study Since 2005, the Aurora Research Institute (ARI) has researched the wind energy potential for communities in the NWT served

More information

Wind Energy Market&Technology

Wind Energy Market&Technology Wind Energy Market&Technology Dr. Eng. Cenk Sevim Energy Specialist Member, World Energy Council Turkish National Committee November, 2013 Content Global Wind Energy Market Turkey Wind Energy Market Basics

More information

Dutch Stereo-RD/NAP 2000 WTG type Shadow data East North Z Row Valid Manufact. Type-generator Power, rated Rotor diameter Hub height Calculation RPM

Dutch Stereo-RD/NAP 2000 WTG type Shadow data East North Z Row Valid Manufact. Type-generator Power, rated Rotor diameter Hub height Calculation RPM Project: SHADOW - Main Result Calculation: 6 Boog Assumptions for shadow calculations Maximum distance for influence Calculate only when more than 20 % of sun is covered by the blade Please look in WTG

More information

Directorate for the Built Environment Building Standards Division

Directorate for the Built Environment Building Standards Division Directorate for the Built Environment Building Standards Division Energy Management Solutions Ltd Investigation of measures to improve the energy performance of a existing building: Retail JUNE 2009 Report

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

CENTRE FOR WIND ENERGY TECHNOLOGY

CENTRE FOR WIND ENERGY TECHNOLOGY CENTRE FOR WIND ENERGY TECHNOLOGY Ref. : C-WET/S&C/RLMM/2013-14/41 Date : 29-10-2013 To All Concerned Dear Sir, Sub: Revised List of Models and Manufacturers of Wind Turbines MAIN LIST The revised MAIN

More information

Copyright 2013 wolfssl Inc. All rights reserved. 2

Copyright 2013 wolfssl Inc. All rights reserved. 2 - - Copyright 2013 wolfssl Inc. All rights reserved. 2 Copyright 2013 wolfssl Inc. All rights reserved. 2 Copyright 2013 wolfssl Inc. All rights reserved. 3 Copyright 2013 wolfssl Inc. All rights reserved.

More information

WIND SHEAR, ROUGHNESS CLASSES AND TURBINE ENERGY PRODUCTION

WIND SHEAR, ROUGHNESS CLASSES AND TURBINE ENERGY PRODUCTION WIND SHEAR, ROUGHNESS CLASSES AND TURBINE ENERGY PRODUCTION M. Ragheb 4//15 INTRODUCTION At a height of about 1 kilometer the wind is barely affected by the surface of the Earth. In the lower atmospheric

More information

EWEA Technology Workshop: Wind Turbine Sound 2014, Malmö Noise Protection Regulations for Wind Turbines in Germany

EWEA Technology Workshop: Wind Turbine Sound 2014, Malmö Noise Protection Regulations for Wind Turbines in Germany For our Environment EWEA Technology Workshop: Wind Turbine Sound 2014, Malmö Noise Protection Regulations for Wind Turbines in Germany Thomas Myck Andrea Bauerdorff Section I 3.4 Noise Abatement of Industrial

More information

WIND TURBINE TECHNOLOGY

WIND TURBINE TECHNOLOGY Module 2.2-2 WIND TURBINE TECHNOLOGY Electrical System Gerhard J. Gerdes Workshop on Renewable Energies November 14-25, 2005 Nadi, Republic of the Fiji Islands Contents Module 2.2 Types of generator systems

More information

Setup Soft PLC Technical handbook

Setup Soft PLC Technical handbook 2 Setup Soft PLC Version V 1.1 Date 05.02.2007 Author Editing/Illustrations Frick Su/Pa Tools This documentation was created with Microsoft Word 2000 and Adobe Illustrator. Trade mark All product names

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION IEC TS 61400-14 First edition 2005-03 Wind turbines Part 14: Declaration of apparent sound power level and tonality values IEC 2005 Copyright - all rights reserved No part of this

More information

INFLUENCE ANALYSIS OF SMALL REPOWERED WIND POWER PLANTS ON THE RELIABILITY OF THE LOCAL GRID

INFLUENCE ANALYSIS OF SMALL REPOWERED WIND POWER PLANTS ON THE RELIABILITY OF THE LOCAL GRID M.SC. ENG. GRZEGORZ BARZYK DR ENG. MIROSŁAW DOPIERA Electrotechnical Engineering Institute, TU Szczecin INFLUENCE ANALYSIS OF SMALL REPOWERED WIND POWER PLANTS ON THE RELIABILITY OF THE LOCAL GRID Key

More information

Nov'turbine. Specifications. v1.1

Nov'turbine. Specifications. v1.1 Nov'turbine Specifications v1.1 2 CONTENTS I -INTRODUCTION... 3 -INTRODUCTION...3 Customization...24 II -Why Noveol... 6 Noveol...6 IV -UK REGULATION... 25 REGULATION...25 1)Quality...7 Height and local-planning

More information

European Technical Assessment ETA-15/0652 of 27/10/2015

European Technical Assessment ETA-15/0652 of 27/10/2015 ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011

More information

/ The allrounder with maximum yield. / WLAN interface / Smart Grid Ready

/ The allrounder with maximum yield. / WLAN interface / Smart Grid Ready / Battery Charging Systems / Welding Technology / Solar Electronics FRONIUS IG PLUS / The allrounder with maximum yield. / Fronius MIX technology / HF transformer switchover / PC board replacement process

More information

Onshore Wind Services

Onshore Wind Services GE Renewable Energy Onshore Wind Services www.ge.com/wind PITCH TABLE OF CONTENTS: 3 Operate and Maintain 3 Asset and Park Management 5 Turbine Maintenance 8 Enhance and Optimize 8 Wind PowerUp * Services

More information

European Aviation Safety Agency

European Aviation Safety Agency European Aviation Safety Agency EASA TYPE-CERTIFICATE DATA SHEET Number: E.070 Issue: 05 Date: 16 November Type: GE Aviation Czech M601/H80 series turboprop engines Models: M601D M601D-1 M601D-2 M601D-11

More information

How To Build A 100Mw Wind Farm In Ques

How To Build A 100Mw Wind Farm In Ques ALTO VALLE WIND FARM - 100 MW Fotomontage of PARQUE EÓLICO DEL ALTO VALLE 100 MW VILLA EL CHOCÓN DEPARTMENT OF CONFLUENCIA PROVINCE OF NEUQUÉN Parque Eólico del Alto Valle S.A. is a company created by

More information

Hub North Netværksarrangement d. 14. Juni 2011

Hub North Netværksarrangement d. 14. Juni 2011 Hub North Netværksarrangement d. 14. Juni 2011 Jan Bisgaard Envision Global Innovation Centre Silkeborg, Denmark Agenda: 1. Presenting (Jan Bisgaard) 2. Company profile 3. Strategies 4. Product road map

More information

WindPRO version 2.7.473 jun 2010 Project:

WindPRO version 2.7.473 jun 2010 Project: -0-0 :09 / Vattenfall Vindkraft /S PRK - Main Result Calculation: 0 Parkberegning Tamholt 5 x SWT.0dd ise OK Wake Model N.O. Jensen (RISØ/) Calculation Settings ir density calculation mode Result for WTG

More information

Testing the Performance of a Ground-based Wind LiDAR System One Year Intercomparison at the Offshore Platform FINO1

Testing the Performance of a Ground-based Wind LiDAR System One Year Intercomparison at the Offshore Platform FINO1 Testing the Performance of a Ground-based Wind LiDAR System One Year Intercomparison at the Offshore Platform FINO1 B. Cañadillas, A. Westerhellweg, T. Neumann; DEWI GmbH, Wilhelmshaven B. Canadillas English

More information

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System Direction Planification des actifs et expertise de transport February 2011 TABLE OF CONTENTS 1. CONDUCTING

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011 Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

EXPERT REMANUFACTURED WIND TURBINE

EXPERT REMANUFACTURED WIND TURBINE EXPERT REMANUFACTURED WIND TURBINE Repowering Solutions is a division of Jeraneas Group of companies. Our core business is the remanufacturing of wind turbines of different sizes; a work that we have been

More information

Relative Power Curve Measurements Using Turbine Mounted, Continuous-Wave Lidar

Relative Power Curve Measurements Using Turbine Mounted, Continuous-Wave Lidar Relative Power Curve Measurements Using Turbine Mounted, Continuous-Wave Lidar Chris Slinger, Matthew Leak, Mark Pitter, Michael Harris ZephIR Ltd., The Old Barns, Fairoaks Farm, Hollybush, Ledbury, Herefordshire,

More information

American Society of Agricultural and Biological Engineers

American Society of Agricultural and Biological Engineers ASAE S580.1 NOV2013 Testing and Reporting Solar Cooker Performance American Society of Agricultural and Biological Engineers ASABE is a professional and technical organization, of members worldwide, who

More information

CRK 2-130 A-W-A-BUBV 85805906

CRK 2-130 A-W-A-BUBV 85805906 GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html

More information

FLOWSTAR-Energy Validation NoordZee Wind Farm

FLOWSTAR-Energy Validation NoordZee Wind Farm FLOWSTAR-Energy Validation NoordZee Wind Farm Cambridge Environmental Research Consultants (CERC) Ltd January 26 Introduction FLOWSTAR-Energy 5. NoordZee is an offshore wind farm in Denmark. A FLOWSTAR-Energy

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Nordex SE. Nordex goes Offshore

Nordex SE. Nordex goes Offshore Nordex SE Nordex goes Offshore Hannover, April 2011 Content 1. Offshore Wind Market 2. Nordex Offshore History & Future 3. Competition & Technical Development 4. The N150/6000 2 Strong growth prospects

More information