CLSME-12. NEMA 12B Rated Aluminium Cable Ladder System

Size: px
Start display at page:

Download "CLSME-12. NEMA 12B Rated Aluminium Cable Ladder System"

Transcription

1 LSME-12 NEM 12 ated luminium able Ladder System

2 ooper Industries and ooper -Line The ooper facility located in Dammam, Saudi rabia, is a 50,000-square foot facility which has been designated as a Saudi ramco and SI-approved facility for ooper products. In order to achieve designation, ooper passed strenuous quality management assessments and strict Saudisation provisions. ooper has also achieved the highest level of the Saudi Local Government Nitaqat Scheme which is measured by the percentage of Saudis in the workforce, a commitment that continues to pay dividends in the local job market. ooper -Line NEM 12 ated able Ladder System To support the MEN region, the ooper Dammam facility offers a wide range of electrical enclosures and support systems including a broad range of ooper -Line aluminium, steel and fiberglass able Ladder Systems to support both commercial and industrial applications. To show further commitment to the region, ooper -Line introduces its latest able Management System in luminium NEM 12 ated able Ladder. The NEM 12 ated able Ladder provides cable management for commercial and light industrial applications. Designed with an I-eam side rail shape, it meets, and in some cases exceeds NEM 12 load and UL classification requirements. The aluminium 6063-T6 construction provides corrosion resistance to help provide a longer lifespan in harsh environments while remaining light weight for easier handling and installation. The system is available in 3, 4, 5 and 6 NEM class load depths and includes straight sections, manufactured fittings, and a full line of accessories for cable and ladder attachment. For more information or to learn more about ooper -Line s able Ladder Systems visit ooper -Line - Saudi rabia: PO ox l Khobar Kingdom of Saudi rabia Phone: Fax: blineme@cooperindustries.com Important notice: The information herein has been carefully checked for accuracy and is believed to be correct and current. No warranty, either expressed or implied, is made as to either its applicability to or its compatibility with specific requirements of this information, nor for damages consequential to its use. ll design characteristics, specifications, tolerances and similar information are subject to change without notice.

3 WI04, WI05, WI06 and WI07 Straight Sections Straight Section Part Numbering Prefix Example: WI SL Series Height Material ottom Type onstruction Length WI 04 = 4 = Ladder = SL = 06 = = 12 ft. 05 = 5 luminium 06 = 6 rung spacing Straight Ladder 09 = = 10 ft. 06 = 4" 09 = 9 rung spacing 12 = = 5" 12 = 12 rung spacing 18 = = 24 ung 30 = 30 Spacing 36 = 36 (Inside) Overall ( /16 ) Values are based on simple beam tests per VE-1 on 36 wide cable ladder with rungs spaced on 12 centers. The published load safety factor is 1.5. To convert 1.5 safety factor to 2.0, multiply the published load by To obtain mid-span deflection, multiply a load by the deflection multiplier. able ladder must be supported on spans shorter than or equal to the length of the tray. These systems will support without collapse a 200 lb. concentrated load. -Line Series WI04 -Line Series WI05 -Line Series WI06 -Line Series WI07 Side ail Dimensions 3.54 Side ail Dimensions Side ail Dimensions Side ail Dimensions NEM, S & UL lassifications NEM, S & UL lassifications Span ft Span ft Load lbs/ft Load lbs/ft Deflection Multiplier Deflection Multiplier Design Factors for Two ails Design Factors for Two ails Span meters Span meters Load kg/m Deflection Multiplier Design Factors for Two ails NEM: rea=1.08 in rea=6.95 cm 2 UL ross-sectional Ix=3.53 in Ix=147.0 cm 4 rea: 0.60 in Sx=1.55 in Sx=25.4 cm 3 Load kg/m Deflection Multiplier Design Factors for Two ails NEM: rea=0.93 in rea=5.99 cm 2 UL ross-sectional Ix=1.96 in Ix=81.70 cm 4 rea: 0.40 in Sx=1.11 in Sx=18.10 cm 3 NEM, S & UL lassifications Span ft Load lbs/ft Deflection Multiplier Design Factors for Two ails Span meters Load kg/m Deflection Multiplier Design Factors for Two ails NEM: rea=1.18 in rea=7.59 cm 2 UL ross-sectional lx=5.51 in Ix=230.0 cm 4 rea: 0.60 in Sx=1.98 in Sx=32.50 cm 3 NEM, S & UL lassifications Span ft Load lbs/ft Deflection Multiplier Design Factors for Two ails Span meters Load kg/m Deflection Multiplier Design Factors for Two ails NEM: rea=1.50 in rea=9.68 cm 2 UL ross-sectional Ix=8.79 in Ix= cm 4 rea: 0.60 in Sx=2.69 in Sx=44.10 cm 3 When cable ladders are used in continuous spans, the deflection of the cable ladder is reduced by as much as 50%. Design factors: Ix = Moment of Inertia, Sx = Section Modulus. 1

4 overs for WI04, WI05, WI06 and WI07 luminium over Part Numbering Prefix Example: SL MM over Type Detail Material Material Thickness over Style Ladder Item Description 86 = Solid 7 = Flanged luminium 40 =.040 SL = 06 = 6 For Straight 87 = Vented Straight 09 = 9 Section over: Ladder 12 = MM = 3M Section 18 = = = = 36 For fitting covers: Insert suffix of fitting to be covered. See examples below. Examples of atalog Numbers for Fitting overs Horizontal end over Prefix Suffix H adius ngle Fitting Material Thickness Material Detail over Type Vertical Inside & Outside end over Prefix Suffix VI/O * Insert I for Inside or O for Outside end Side ail Height adius ngle Fitting Material Thickness Material Detail over Type Horizontal Expanding ross over Prefix Suffix X adius 2 1 Fitting Material Thickness Material Detail over Type Standard over lamp Setscrew included. For indoor service only. Sold each. Heavy Duty over lamp For heavy duty application. Sold per piece. Ladder Series atalog No. Ladder Type luminium Side ail Height ll Sizes atalog No. 9ZN WI04 WI05 WI06 WI07 = tray width 4-HD- 5-HD- 6-HD- 7-HD- 2

5 ccessories Standard Splice Plates Furnished in pairs with 1/4 hardware. UL lassified. One pair including hardware provided with each straight section. Offset educing Splice Plates Furnished in pairs with 1/4 hardware. UL lassified. Flex-Mount djustable Splice Plates Furnished in pairs with 1/4 hardware. Horizontally adjustable to 90. Vertically adjustable to 15. UL lassified. equires supports within 24 on both sides, per NEM VE 2. Ladder Series WI04 atalog No. 4-SSP ight (or Left) educer Ladder Series WI04 atalog No. 4-FSP WI05 5-SSP WI05 5-FSP WI06 6-SSP WI06 6-FSP WI07 7-SSP WI07 7-FSP Step Down Splice Plates Furnished in pairs with 1/4 hardware. UL lassified. Ladder Series WI05 to WI04 WI06 to WI04 WI07 to WI04 WI06 to WI05 WI07 to WI05 WI07 to WI06 atalog No. -DSP-45 -DSP-46 -DSP-47 -DSP-56 -DSP-57 -DSP-67 enter educer Ladder Series WI04 WI05 WI06 WI07 Specify the following: = center reducer S = side reducer atalog No. 4-SP- r 5-SP- r 6-SP- r 7-SP- r r (ladder reduction) 3, 6, 9, 12, 15, 18, 21, 24, 27 or 30 Tray To ox Splice Plates Furnished in pairs with 1/4 hardware. UL lassified. Ladder Series WI04 WI05 WI06 WI07 atalog No. 4-TT 5-TT 6-TT 7-TT Vertical djustable Splice Plates Furnished in pairs with 1/4 hardware. UL lassified. Expansion Splice Plates Furnished in pairs with 1/4 hardware. onding jumper required. equires supports within 24 on both sides, per NEM VE 2. Ladder Series atalog No. Ladder Series atalog No. WI04 4-VSP WI04 4-ESP WI05 5-VSP WI05 5-ESP WI06 6-VSP WI06 6-ESP WI07 7-VSP WI07 7-ESP 3

6 ccessories onding Jumper Furnished with 1/4 hardware. UL lassified. mpacity atalog No lamp/guide Features a no-twist design. Has four times the strength of the traditional design. Each side is labeled to ensure proper installation. Designed for 1/4 hardware. Furnished in pairs with or without hardware. Patent No. E (38mm) atalog No. 9ZN-1204 (without hardware) 9ZN-1204N (with hardware) onduit to Ladder daptors onduit Size atalog No. in mm 1/2, 3/4 15, 20 9G /2, 3/4 1, 11/4 25, 32 9G , 1 1/4 1 1/2, 2 40, 50 9G /2, 2 2 1/2, 3 65, 80 9G /2, 3 3 1/2, 4 90, 100 9G /2, 4 Ladder Drop-Out Specially-designed Ladder Drop-Outs provide a rounded surface with 4 (101 mm) radius to protect cable as it exits from the cable tray, preventing damage to insulation. The drop-out will attach to any desired rung. ( ) Insert tray width lind End Furnished as one plate with 1/4 hardware. atalog No = ladder width Trapeze Support Kit Single Trapeze Support in one package is available in pre-galvanized steel with zinc-plated hardware or hot dip galvanized steel with 316 stainless steel hardware. SH hannel provides pre-punched slots eliminating field drilling. Hardware is sealed in plastic bag and boxed with channel that is pre-cut to appropriate length. Designed for use with 1/2 threaded rod. Order rod separately. ( ) Insert 3/8 for 3/8 threaded rod hardware. Safety factor of 3.0 on all loads. atalog No. Ladder in mm (4) 1/2 Hex Nut (4) 202 Square Washer hannel Length in mm (2) 1/2 x 7/8 Hex Head ap Screw (2) 9ZN-1205 Hold-Down Guide lamp (2) N525WO hannel Nut (1) 22 hannel cut to the required length Uniform Load in mm 9P SH( ) P SH( ) P SH( ) P SH( ) P SH( ) P SH( ) P SH( ) P SH( ) = ladder width Ladder Series WI04 WI05 WI06 WI07 Ladder Series WI04 WI05 WI06 WI07 = tray width atalog No. 4-END- 5-END- 6-END- 7-END- Frame Type ox onnector Furnished with 1/4 hardware for tray connection. atalog No. 4-FT- 5-FT- 6-FT- 7-FT- 4

7 ccessories Straight Section arrier Strip Furnished with four (4) barrier strip clips, mounting hardware and splice. Standard lengths are 144 (12 ft) & 120 (10 ft). Horizontal end arrier Strip Horizontal end arriers are flexible in order to conform to any horizontal fitting radius. Furnished with three (3) barrier strip clips, mounting hardware and splice. Standard length is 72 (6 ft). Ladder Series H atalog No. WI04 4-DSL-Length 3 76 in H mm WI05 5-DSL-Length WI06 6-DSL-Length WI07 7-DSL-Length Ladder Series H atalog No. WI04 4-DH 3 76 in H mm WI05 5-DH WI06 6-DH WI07 7-DH Vertical end arrier Strip Furnished with three (3) barrier strip clips, mounting hardware and splice. Inside end (VI) H H Outside end (VO) Ladder atalog No. H Series Inside end Outside end in mm WI04 4-DVI-(**)( ) 4-DVO-(**)( ) 3 76 WI05 5-DVI-(**)( ) 5-DVO-(**)( ) WI06 6-DVI-(**)( ) 6-DVO-(**)( ) WI07 7-DVI-(**)( ) 7-DVO-(**)( ) (**) Insert 30, 45, 60, 90 for angles ( ) Insert 12, 24 for radius 5

8 Fittings For WI04, WI05, WI06 and WI07 Horizontal Tee Furnished with splice plates. Horizontal end 1 2 Vertical Inside Vertical Outside Vertical Tee Down Shown Fittings Part Numbering Prefix Suffix Example: WI H Series Height Material Fitting Type ngle adius WI 04 = 4 luminium H = Horizontal end 06 = 6 30 = = = 5 9 ung *HT = Horizontal Tee 09 = 9 45 = = = 6 Spacing *HX = Horizontal ross 12 = = = = 7 VI = Vertical Inside end 18 = = 90 VO = Vertical Outside end 24 = 24 *ngle not required in part number *VTD = Vertical Tee Down 30 = 30 *VTU = Vertical Tee Up 36 = 36 Horizontal educing / Expanding Tee or ross Fittings Part Numbering Example: Prefix Suffix WI ET Series Height Material Fitting Type 1 2 ngle adius WI 04 = 4 luminium ET = Expanding Tee 06 = 6 06 = 6 12 = = 5 9 ung T = educing Tee 09 = 9 09 = 9 24 = = 6 Spacing X = Expanding/ 12 = = = = 7 educing ross 18 = = = = = = = = 36 6

9 end adius Ladder 90 Horizontal end Dimensions 60 Horizontal end Dimensions in. mm in. mm atalog No. atalog No H 60 H Fittings Horizontal ends (H) (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / /2 495 (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / /8 561 (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / (Pre)H / / / (Pre)H / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / Horizontal end Dimensions 30 Horizontal end Dimensions 1 pair splice plates with hardware included. ottoms manufactured: 09 = 9 ung Spacing ll dimensions in grey shaded boxes are millimeters unless otherwise specified. dimensions are to inside wall. Manufacturing tolerances apply to all dimensions (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / /2 190 (Pre)H / / /2 267 (Pre)H / / / (Pre)H / / /4 298 (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / /4 362 (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / /8 302 (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / / (Pre)H / / /4 489 (Pre)H / / / (Pre)H / / (Pre)H / / (Pre)H / / / (Pre)H / / / (Pre)H / / (Pre)H / / /8 384 (Pre)H / / / (Pre)H / / (Pre)H / / (Pre)H / / / (Pre)H / / / (Pre)H / / / H 30 H

10 end adius Ladder W atalog No. Fittings Horizontal Tee Dimensions in. mm in. mm in. mm in. mm (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / (Prefix)HT / / end adius Ladder W atalog No. Horizontal ross Dimensions in. mm in. mm in. mm in. mm (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / (Prefix)HX / / Horizontal Tee (HT) 2 pair splice plates with hardware included. Horizontal ross (HX) 3 pair splice plates with hardware included. ll dimensions in grey shaded boxes are millimeters unless otherwise specified. dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. HT W HX W 8

11 Fittings Horizontal educing Tee (T) 2 pair splice plates with hardware included. Prefix T T adius W2 W1 Fitting To complete catalog number, insert fitting prefix. = adius W2 W1 Ladder *Insert adius 12 adius 24 adius 36 adius W1 W2 (12 for 12, 24 for 24 or 36 for 36 ) in. mm in. mm atalog No. in. mm in. mm in. mm in. mm in. mm in. mm (Prefix)T * 199/ / / / / / (Prefix)T * 211/ / / / / / (Prefix)T * 211/ / / / / / (Prefix)T * 241/ / / / / / (Prefix)T * 241/ / / / / / (Prefix)T * 241/ / / / / / (Prefix)T * 271/ / / / / / (Prefix)T * 271/ / / / / / (Prefix)T * 271/ / / / / / (Prefix)T * 271/ / / / / / (Prefix)T * 301/ / / / / / (Prefix)T * 301/ / / / / / (Prefix)T * 301/ / / / / / (Prefix)T * 301/ / / / / / (Prefix)T * 301/ / / / / / (Prefix)T * 331/ / / / / / (Prefix)T * 331/ / / / / / (Prefix)T * 331/ / / / / / (Prefix)T * 331/ / / / / / (Prefix)T * 331/ / / / / / (Prefix)T * 331/ / / / / / ll dimensions in grey shaded boxes are millimeters unless otherwise specified. dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. 9

12 Fittings Horizontal Expanding Tee (ET) 2 pair splice plates with hardware included. ET Prefix ET W1 = adius W2 adius W2 W1 Fitting To complete catalog number, insert fitting prefix. Ladder *Insert adius 12 adius 24 adius 36 adius W1 W2 (12 for 12, 24 for 24 or 36 for 36 ) in. mm in. mm atalog No. in. mm in. mm in. mm in. mm in. mm in. mm (Prefix)ET * 181/ / / / / / (Prefix)ET * 181/ / / / / / (Prefix)ET * 181/ / / / / / (Prefix)ET * 181/ / / / / / (Prefix)ET * 181/ / / / / / (Prefix)ET * 181/ / / / / / (Prefix)ET * 199/ / / / / / (Prefix)ET * 199/ / / / / / (Prefix)ET * 199/ / / / / / (Prefix)ET * 199/ / / / / / (Prefix)ET * 199/ / / / / / (Prefix)ET * 211/ / / / / / (Prefix)ET * 211/ / / / / / (Prefix)ET * 211/ / / / / / (Prefix)ET * 211/ / / / / / (Prefix)ET * 241/ / / / / / (Prefix)ET * 241/ / / / / / (Prefix)ET * 241/ / / / / / (Prefix)ET * 271/ / / / / / (Prefix)ET * 271/ / / / / / (Prefix)ET * 301/ / / / / / ll dimensions in grey shaded boxes are millimeters unless otherwise specified. dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. 10

13 Fittings Horizontal Expanding/educing ross (X) 3 pair splice plates with hardware included. Prefix X X adius W2 W1 Fitting To complete catalog number, insert fitting prefix. W2 W1 Ladder *Insert adius 12 adius 24 adius 36 adius W1 W2 (12 for 12, 24 for 24 or 36 for 36 ) in. mm in. mm atalog No. in. mm in. mm in. mm in. mm in. mm in. mm (Prefix)X * 363/ / / / / / (Prefix)X * 363/ / / / / / (Prefix)X * 363/ / / / / / (Prefix)X * 363/ / / / / / (Prefix)X * 363/ / / / / / (Prefix)X * 363/ / / / / / (Prefix)X * 397/ / / / / / (Prefix)X * 397/ / / / / / (Prefix)X * 397/ / / / / / (Prefix)X * 397/ / / / / / (Prefix)X * 397/ / / / / / (Prefix)X * 421/ / / / / / (Prefix)X * 421/ / / / / / (Prefix)X * 421/ / / / / / (Prefix)X * 421/ / / / / / (Prefix)X * 481/ / / / / / (Prefix)X * 481/ / / / / / (Prefix)X * 481/ / / / / / (Prefix)X * 5413/ / / / / / (Prefix)X * 5413/ / / / / / (Prefix)X * 601/ / / / / / ll dimensions in grey shaded boxes are millimeters unless otherwise specified. dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. 11

14 Fittings Vertical end 90 (VO, VI) 1 pair splice plates with hardware included. 90 Vertical Inside (VI) end end Siderail Height adius atalog No. 4" 5" 6" 7" in. mm in mm (Pre)VI (Pre)VI (Pre)VI /2 181/2 181/2 191/2 191/2 191/2 201/2 201/2 201/2 211/2 211/2 211/ (Pre)VI (470) (470) (470) (495) (495) (495) (521) (521) (521) (546) (546) (546) (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI /2 301/2 301/2 311/2 311/2 311/2 321/2 321/2 321/2 331/2 331/2 331/2 (775) (775) (775) (800) (800) (800) (825) (825) (825) (851) (851) (851) (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI /2 421/2 421/2 431/2 431/2 431/2 441/2 441/2 441/2 451/2 451/2 451/2 (1080) (1080) (1080) (1105) (1105) (1105) (1130) (1130) (1130) (1156) (1156) (1156) (Pre)VI (Pre)VI (Pre)VI Vertical Outside (VO) end end Siderail Height adius atalog No. 4"-7" in. mm in mm (Pre)VO (Pre)VO (Pre)VO (Pre)VO (381) (381) (381) (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (686) (686) (686) (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (991) (991) (991) (Pre)VO (Pre)VO (Pre)VO Vertical Outside 90 VI 90 Vertical Inside ll dimensions in grey columns or in parentheses are millimeters unless otherwise specified. Manufacturing tolerances apply to all dimensions. 90 VO 12

15 Fittings Vertical end 60 (VO, VI) 1 pair splice plates with hardware included. end adius 60 Vertical Inside (VI) end atalog No. Siderail Height 4" 5" 6" 7" in. mm in mm (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (457) 283/8 (721) 383/4 (984) 103/8 (263) 163/8 (416) 223/8 (568) 12 (305) 1815/16 (481) 257/8 (657) 1813/16 (478) 291/4 (743) 395/8 (1006) 107/8 (276) 167/8 (428) 227/8 (581) 129/16 (319) 191/2 (495) 267/16 (672) 1911/16 (500) 301/16 (763) 401/2 (1029) 113/8 (289) 173/8 (441) 233/8 (594) 131/8 (333) 201/16 (509) 27 (686) 209/16 (522) 3015/16 (786) 413/8 (1051) 117/8 (301) 177/8 (454) 237/8 (606) 1311/16 (347) 205/8 (524) 279/16 (700) end adius 60 Vertical Outside (VO) end atalog No. Siderail Height 4"-7" in. mm in mm (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO /8 (378) 255/16 (643) 353/4 (908) 85/8 (219) 145/8 (371) 205/8 (524) 915/16 (252) 167/8 (428) 2313/16 (605) 60 VI 60 Vertical Inside 60 Vertical Outside ll dimensions in grey columns or in parentheses are millimeters unless otherwise specified. Manufacturing tolerances apply to all dimensions. 60 VO 13

16 Fittings Vertical end 45 (VO, VI) 1 pair splice plates with hardware included. 45 Vertical Inside (VI) end end Siderail Height adius atalog No. 4" 5" 6" 7" in. mm in mm (Pre)VI (Pre)VI (Pre)VI (Pre)VI /8 611/16 97/16 167/8 7 97/8 179/16 71/4 101/4 181/4 79/ /16 (409) (170) (239) (428) (178) (251) (446) (184) (260) (463) (192) (271) (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI /8 103/16 147/16 255/16 101/2 1413/ /4 151/4 263/4 111/16 155/8 (625) (259) (366) (643) (267) (376) (660) (273) (387) (679) (281) (397) (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI /8 133/4 197/ / /16 349/ /16 201/4 351/4 145/8 205/8 (841) (349) (494) (859) (356) (503) (878) (364) (514) (895) (371) (524) (Pre)VI (Pre)VI (Pre)VI Vertical Outside (VO) end end Siderail Height adius atalog No. 4"-7" in. mm in mm (Pre)VO (Pre)VO (Pre)VO /8 55/ (Pre)VO (346) (136) (203) (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO /8 93/ / (Pre)VO (562) (233) (328) (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO / / (Pre)VO (779) (322) (457) (Pre)VO (Pre)VO (Pre)VO VI 45 Vertical Inside 45 Vertical Outside 45 VO ll dimensions in grey columns or in parentheses are millimeters unless otherwise specified. Manufacturing tolerances apply to all dimensions. 14

17 Vertical end 30 (VO, VI) 1 pair splice plates with hardware included. Fittings end adius 45 Vertical Inside (VI) end atalog No. Siderail Height 4" 5" 6" 7" in. mm in mm (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI (Pre)VI /16 (341) 197/16 (493) 257/16 (646) 35/8 (92) 53/16 (132) 613/16 (173) 73/16 (182) 107/16 (265) 135/8 (346) 1315/16 (354) 1915/16 (506) 2515/16 (659) 33/4 (95) 55/16 (135) 615/16 (176) 77/16 (189) 1011/16 (271) 137/8 (352) 147/16 (366) 207/16 (519) 267/16 (672) 37/8 (98) 57/16 (138) 71/16 (179) 73/4 (197) 1015/16 (278) 143/16 (360) 147/8 (378) 207/8 (530) 2615/16 (684) 4 (101) 55/8 (143) 71/4 (184) 8 (203) 113/16 (284) 147/16 (367) end adius 45 Vertical Outside (VO) end atalog No. Siderail Height 4"-7" in. mm in mm (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO (Pre)VO /8 (295) 175/8 (447) 2311/16 (602) 31/8 (79) 43/4 (120) 65/16 (160) 61/4 (159) 97/16 (239) 123/4 (324) 30 VI 30 Vertical Inside 30 VO 30 Vertical Outside ll dimensions in grey columns or in parentheses are millimeters unless otherwise specified. Manufacturing tolerances apply to all dimensions. 15

18 Fittings Vertical Tee Up/Down (VTU/VTD) 2 pair splice plates with hardware included. VTD VT H VTU end Siderail Height "H" adius atalog No. 4"-7" 4" 5" 6" 7" in. mm in mm in mm in mm in mm in mm in mm (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) / / / /8 924 (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) / / / / (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) / / / / (Prefix)VT(*) (Prefix)VT(*) (Prefix)VT(*) ll dimensions in grey shaded boxes are millimeters unless otherwise specified. Manufacturing tolerances apply to all dimensions. 16

19 Specifications - Section 161xx - NEM 12 luminium able Ladder Part 1 - General 1.01 Section Includes. The work covered under this section consists of the furnishing of all necessary labour, supervision, materials, equipment, tests and services to install complete cable ladder systems as shown on the drawings.. able ladder systems are defined to include, but are not limited to straight sections of [ladder type] cable ladders, bends, tees, elbows, drop-outs, supports and accessories eferences. NSI/NFP 70 - National Electrical ode. NEM VE Metallic able Ladder Systems. NEM VE able Ladder installation Guidelines 1.03 Drawings. The drawings, which constitute a part of these specifications, indicate the general route of the cable ladder systems. Data presented on these drawings are as accurate as preliminary surveys and planning can determine until final equipment selection is made. ccuracy is not guaranteed and field verification, of all dimensions, routing, etc., is directed.. Specifications and drawings are for assistance and guidance, but exact routing, locations, distances and levels will be governed by actual field conditions. ontractor is directed to make field surveys as part of his work prior to submitting system layout drawings Submittals. Submittal Drawings: Submit drawings of cable ladder and accessories including clamps, brackets, hanger rods, splice plate connectors, expansion joint assemblies, and fittings, showing accurately scaled components.. Product Data: Submit manufacturer s data on cable ladder including, but not limited to, types, materials, finishes, rung spacings, inside depths and fitting radii. For side rails and rungs, submit cross sectional properties including Section Modulus (Sx) and Moment of Inertia (Ix) Quality ssurance. Manufacturers: Firms regularly engaged in manufacture of cable ladders and fittings of types and capacities required, whose products have been in satisfactory use in similar service for not less than 5 years.. NEM ompliance: omply with NEM Standards Publication Number VE 1, able Ladder Systems.. NE ompliance: omply with NE, as applicable to construction and installation of cable ladder (rticle 392, NE). D. UL ompliance: Provide products that are UL-classified and labeled. E. NFP ompliance: omply with NFP 70, ecommended Practice for Electrical Equipment Maintenance pertaining to installation of cable ladder systems Delivery, Storage and Handling. Deliver cable ladder systems and components carefully to avoid breakage, denting and scoring finishes. Do not install damaged equipment.. Store cable ladders and accessories in original cartons and in clean dry space; protect from weather and construction traffic. Wet materials should be unpacked and dried before storage. Part 2 - Products 2.01 cceptable Manufacturers. Subject to compliance with these specifications, cable ladder systems shall be as manufactured by ooper -Line, Inc able Ladder Sections and omponents. General: Except as otherwise indicated, provide metal cable ladders, of types, classes, and sizes indicated; with splice plates, bolts, nuts and washers or connecting units. onstruct units with rounded edges and smooth surfaces; in compliance with applicable standards; and with the following additional construction features. able ladder shall be installed according to the latest revision of NEM VE-2.. Material and Finish: Straight sections, fitting side rails, rungs and splice plates shall be extruded from luminium ssociation lloy ll fabricated parts shall be made from luminium ssociation lloy Type of Ladder System. Ladder able ladders shall consist of two longitudinal members (side rails) with transverse members (rungs) mechanically fastened to the side rails. ungs shall be spaces [6] [9] [12] inches on center. ung spacing in radiused fittings shall be industry standard 9 and measured at the center of the ladder's width. Each rung must be capable of supporting lb. concentrated load at the center of a 18 wide cable ladder with a safety factor of 1.5. ungs shall be capable of easy removal, reinstallation, or replacement if necessary.. able Ladder loading depth shall be [3] [4] [5] [6] inches per NEM VE-1.. Straight sections shall be supplied in standard [10 foot (3.05m)] [12 foot (3.65m)] lengths. D. able Ladder widths shall be [6] [9] [12] [18] [24] [30] [36] inches or as shown on drawings. E. Splice plates shall have (4) four nuts and bolts per plate. The resistance of fixed splice connections between adjacent sections of ladder shall not exceed ohms. Splice plates shall be furnished with straight sections and fittings. F. ll fittings must have a minimum radius of [12] [24] [36] inches Loading apacities. able ladders shall meet NEM class designation: [75 lbs./ft. on 12 ft. span]. O. able ladder shall be capable of carrying a uniformly distributed load of lbs./ft on a foot support span with a safety factor of 1.5 when supported as a simple span and tested per NEM VE 1 Section 5.2. Part 3 - Execution 3.01 Installation. Install cable ladders as indicated: Installation shall be in accordance with equipment manufacturer s instructions, and with recognized industry practices to ensure that cable ladder equipment comply with requirements of NE and applicable portions of NFP 70. eference NEM VE-2 for general cable ladder installation guidelines.. oordinate cable ladder with other electrical work as necessary to properly integrate installation of cable ladder work with other work.. Provide sufficient space encompassing cable ladders to permit access for installing and maintaining cables. D. able ladder fitting supports shall be located such that they meet the strength requirements of straight sections. Install fitting supports per NEM VE-2 guidelines, or in accordance with manufacturer s instructions Testing. Test cable ladders to ensure electrical continuity of bonding and grounding connections, and to demonstrate compliance with specified maximum grounding resistance. See NFP 70, hapter 18, for testing and test methods.. Manufacturer shall provide test reports witnessed by an independent testing laboratory of the worst case loading conditions outlined in this specification and performed in accordance with the latest revision of NEM VE /S 22.2 No End Of Section. 17

20 ooper -Line s U.S. ustomer Service enter is staffed Monday through Friday from 7 a.m. to 5:00 p.m. entral Standard Time. If a situation requires that you have to contact us after hours, please leave a message via phone or so we can give it immediate attention the following business day. Service Facility - United States: ooper -Line - US 509 West Monroe Street Highland, IL United States Phone: (800) Fax: (800) blineus@cooperindustries.com Service Facility - anada: ooper -Line - anada Div. of ooper Ind. anada, Inc McLaughlin oad Mississauga, ON L5 18 anada Phone: (800) Fax: (888) blinecanada@cooperindustries.com Service Facility - Europe: ooper -Line, Ltd. - UK Walrow, Highbridge Somerset, T9 4Q United Kingdom Phone: + 44 (0) Fax: + 44 (0) sales@cooperbline.co.uk ooper -Line - Saudi rabia: PO ox l Khobar Kingdom of Saudi rabia Phone: Fax: blineme@cooperindustries.com Literature Fulfillment Questions: Phone: (314) Fax: (314) cooperbline@repcographics.com equest Literature Website: ooper -Line, Saudi rabia PO ox l Khobar Kingdom of Saudi rabia Phone: Ext 123 or Ext 224 Fax: Saudi_Quote@cooperindustries.com ooper US, Inc. 600 Travis, Ste Houston, TX Phone: ooper -Line, Inc. LSME-12

Series 1 Steel Cable Ladder

Series 1 Steel Cable Ladder able Straight Sections See pages LDS-3 & LDS-4 Straight Section overs See page LDS-10 ccessories See pages LDS-5 - LDS-9 Fittings See pages LDS-11 - LDS-17 Fitting overs See page LDS-10 LDS-1 able Support

More information

T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough

T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough Tray Bottom Types Ladder Extra wide aluminum rungs are welded to extruded aluminum I-beam siderails. Every second rung is reversed to allow for easy top or bottom mounting of cable ties and clamps. All

More information

SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. SECTION 260536 - CABLE TRAYS PART 1 - GENERAL SECTION INCLUDES: A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. B. Cable tray systems are defined to include, but

More information

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

CT-02 CABLE TRAY SYSTEMS

CT-02 CABLE TRAY SYSTEMS CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry

More information

Cable Tray Straight Sections Pages 5-11. Fittings Pages 10-17. Inside Vertical Bends. 90 Page 1-12 60 Page 1-13 45 Page 1-14 30 Page 1-15

Cable Tray Straight Sections Pages 5-11. Fittings Pages 10-17. Inside Vertical Bends. 90 Page 1-12 60 Page 1-13 45 Page 1-14 30 Page 1-15 Tray When metal ladder cable trays came of age, they were used to support the new armored shielded power cables that were permitted outside the conduit environment. Utilities and industrial companies initiated

More information

Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP

Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP Metallic Snap-In Splice Plate Designed to lock into place for easy alignment and installation. Packaged in pairs with zinc plated hardware. Provided as standard with each straight and fitting. Cat. No.

More information

SECTION 4: Cable Ladder Stainless Steel & Aluminium

SECTION 4: Cable Ladder Stainless Steel & Aluminium SECTION 4: Cable Ladder & Aluminium Type 3/50 (NEMA 6A) Type 4/70L Type 5/112 (NEMA 20C) > 4:3 > 4:4 > 4:5 Aluminium Type 4/70A (NEMA 16B) Ladder Splice Plates > 4:7 > 3:18 Page 4:1 Cable Ladder General

More information

Cable Tray Ladder, Trough, Channel, Under Floor, Shielded CH-115C

Cable Tray Ladder, Trough, Channel, Under Floor, Shielded CH-115C Cable Tray Ladder, Trough, Channel, Under Floor, Shielded CH-11C Chalfant dvantages Why Chalfant? Chalfant knows its success over the past 7 years can be traced to providing more than just quality cable

More information

Cable Runways & Accessories

Cable Runways & Accessories SB17U SB13AL SB17 SB17T SB117 SB17HRB SB2107 SB2101A SB17VRB SB2110A SB2129 SB2129SD SB130 SB2221 SB126 SB2118 SB119 SB2105 113 Cooper B-Line manufactures a wide variety of high quality cable pathway products

More information

Ladder. Ladder Style Cable Tray. Typical Installations. Chalfant Cable Trays

Ladder. Ladder Style Cable Tray. Typical Installations. Chalfant Cable Trays Style Cable Tray Typical Installations Chalfant Cable Trays Tray When metal ladder cable trays came of age, they were used to support the new armored shielded power cables that were permitted outside the

More information

Ladder Tray. Ladder. shafts (the only prohibition on cable tray use) conductor (classified by UL) and operation

Ladder Tray. Ladder. shafts (the only prohibition on cable tray use) conductor (classified by UL) and operation Tray When metal ladder cable trays came of age, they were used to support the new armored shielded power cables that were permitted outside the conduit environment. Utilities and industrial companies initiated

More information

DELTA3-1. Delta 3 Data Centre Rack Solution

DELTA3-1. Delta 3 Data Centre Rack Solution DELTA3-1 Delta 3 Data Centre Rack Solution Contents Building on more than 50 years of British design and innovation, Cooper B-Line introduces Delta 3 ( Delta cubed ). Designed to offer M.O.R.E. to customers

More information

ONTRAC WIRE MESH CABLE TRAY SYSTEM

ONTRAC WIRE MESH CABLE TRAY SYSTEM P R O D U C T D ATA S H E E T ONTRAC WIRE MESH CABLE TRAY SYSTEM K E Y F E AT U R E S Available in two styles: Shaped and Standard Tray Easy to use pathway solution that supports large quantities of network

More information

EMI/RFI Shielded Cable Tray

EMI/RFI Shielded Cable Tray EMI/RFI Cable Tray Chalfant began supplying industry cable tray in 1948 and designed and developed the first RF Tray for NS in 196 when it became imperative to protect instrument and control cabling from

More information

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia Exel Composites Cable Support Systems offer engineers a structural product for solving many design and plant engineering problems, enabling long term reliable support of expensive and often critical cables.

More information

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER

More information

Type 1, 3, & 3R Enclosures

Type 1, 3, & 3R Enclosures Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................

More information

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER Page 1 of 6 FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER 0 Issued for Review & Comments Rev. Date Description Eng. A.H Prepared by Checked by Approved by Page 2 of 6 REVISION CONTROL SHEET REV. NO. DATE

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family

More information

glass & Glazing Products

glass & Glazing Products glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system

More information

CDGRD-10. Grounding. Solutions For Comm/Data Applications

CDGRD-10. Grounding. Solutions For Comm/Data Applications CDGRD-10 Grounding Solutions For Comm/Data Applications Overview & Table of Contents Cooper B-Line s Grounding products for rack & runway provide a complete solution for grounding metal supports. The offering

More information

Safety Grating GSSG-13R GRIP STRUT. safety grating

Safety Grating GSSG-13R GRIP STRUT. safety grating Safety Grating GSSG-13R safety grating Table of Contents & Advantages Advantages.................................................... 2 Proof Of Performance...................................... 3 General

More information

Cable Support Solutions

Cable Support Solutions Cable Support Solutions B-Line by Eaton Technology Day Japan 2013 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved.

More information

Cable & Wire Management

Cable & Wire Management able & ire Management able & ire Management Lay-In ireway Type 1 Screw over... 8-14 Lay-In ireway Type 1 Quick-onnect inge over... 15-20 Lay-In ireway Type 3R EnviroShield... 21-24 Lay-In ireway Type 12...

More information

PW Cable Tray Ladder, Trough & Solid Bottom

PW Cable Tray Ladder, Trough & Solid Bottom PW Cable ray adder, rough & Solid Bottom Metallic Covers & Cover Connectors Covers protect and contain cables. hey are highly recommended to avoid damage to the tray contents and to protect against the

More information

Cable Trays Technical Instructions & Specifications

Cable Trays Technical Instructions & Specifications Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,

More information

FiberGuide Fiber Management Systems. 4th Edition

FiberGuide Fiber Management Systems. 4th Edition FiberGuide Fiber Management Systems 4th Edition Table of Contents Introduction Introduction...1 A Variety of Solutions...2 Innovative Products...3 Features and Benefits... 4 Applications Combining System

More information

AIR CONDITIONING PRODUCTS COMPANY

AIR CONDITIONING PRODUCTS COMPANY Quality Products Fixed Louvers AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Best Practice Guide to Cable Ladder and Cable Tray Systems

Best Practice Guide to Cable Ladder and Cable Tray Systems Best Practice Guide to Cable Ladder and Cable Tray Systems Channel Support Systems and other Associated Supports November 2012 BEAMA Best Practice Guide to Cable Ladder and Cable Tray Systems Including

More information

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical

More information

SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS

SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications

More information

GUARDRAIL INNOVATION FLOWS FROM HERE

GUARDRAIL INNOVATION FLOWS FROM HERE INNOVATION FLOWS FROM HERE ENSURING SAFETY ON CANADIAN HIGHWAYS The economics, versatility, and performance of Guardrail surpass all other roadside barrier systems. Guardrail provides highly-visible protection

More information

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers SnapStak Hangers New design increases stack height SnapStak hangers have become the industry standard for maximizing space utilization on crowded towers and now that utility is further expanded with the

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

WHI 90-Minute Rated Veneered Door Frame Installation Instructions No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,

More information

Cat. No. Finishes & Materials. Standard Finish: Electrogalvanized. Change suffix to SS6(C).

Cat. No. Finishes & Materials. Standard Finish: Electrogalvanized. Change suffix to SS6(C). Superstrut Support Systems 1-5/8 in. x 1-5/8 in. Channel and Hardware Superstrut 1-5/8 in. x 1-5/8 in. - 12 Gauge Channel Type A Solid Base Punched Description Solid base -P Punched -HS Half slots Half

More information

Owner's Manual & Assembly Instructions

Owner's Manual & Assembly Instructions Owner's Manual & Assembly Instructions PM01 BASE KIT Model No. FDN1014 717090311 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY

More information

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware. 14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined

More information

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment

More information

CLEAR-DIVISIONS APERTO

CLEAR-DIVISIONS APERTO CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the

More information

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,

More information

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1 ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR

More information

Data Center Solutions Guide. Solutions to Support, Protect, Enclose and Connect Data Center Equipment and Infrastructure

Data Center Solutions Guide. Solutions to Support, Protect, Enclose and Connect Data Center Equipment and Infrastructure Data Center Solutions Guide Solutions to Support, Protect, Enclose and Connect Data Center Equipment and Infrastructure Data Center Solutions Overview Cooper B-Line is your one-stop resource for support

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

KwikSplice cable tray system Save up to 50% on material and installation time

KwikSplice cable tray system Save up to 50% on material and installation time Cable management KSVP-14 KwikSplice cable tray system Save up to 50% on material and installation time KwikSplice cable tray system The KwikSplice cable tray systems innovative two bolt splice connection,

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

CABLE SUPPORT SYSTEMS

CABLE SUPPORT SYSTEMS CABLE SUPPORT SYSTEMS eaturing the CADDY CAT HP J-Hook System Why CADDY CAT HP? Why Choose CADDY CAT HP over tray? ast and Easy to Install Much faster installation compared to conventional cable or ladder

More information

Dock Hardware & Accessory Products Catalog

Dock Hardware & Accessory Products Catalog Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

Flextray - Installation. Installation

Flextray - Installation. Installation 50 Flextray Cutters Part Qty./Box Wt./Box Number lbs. kg CLEANSHEAR Cleanshear 1 4.3 1.95 Cutting Tool Exclusive, patented Cleanshear cuts tray fast No sharp edges Designed specifically for cutting Flextray

More information

RPS - sales@rpssolar.com - 858 755 4505-12478 San Bruno Cove, San Diego, CA 92130

RPS - sales@rpssolar.com - 858 755 4505-12478 San Bruno Cove, San Diego, CA 92130 RPS - sales@rpssolar.com - 858 755 4505-2478 San Bruno Cove, San Diego, CA 9230 SWH Solar Mount Rail R-MR-SW-SR-0.5, R-MR-SW-SR-2, R-MR-SW-SR-4, R-MR-SW-SR-4B, R-MR-SW-SR-7 Part No. MR-SW-SR-0.5, MR-SW-SR-2,

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

Includes specifications for: Surface Cleaning & Mounting Hardware.

Includes specifications for: Surface Cleaning & Mounting Hardware. Three-Part Specifications - Copyright 2014 - Nixalite of America Inc Bird Screen Welded Wire Mesh Barriers Includes specifications for: Surface Cleaning & Mounting Hardware. Nixalite offers full rolls

More information

I BEAM TRACK INSTALLATION

I BEAM TRACK INSTALLATION PDQ 0/700 FESTOON SYSTEM INSTALLATION AND MAINTENANCE INSTRUCTIONS INTRODUCTION The PDQ Festoon System was designed to run on one of three sizes of I-beams: S x., S8 x 8. and S x.. System trolleys must

More information

Preformed Metal Roofing and Siding

Preformed Metal Roofing and Siding Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision

More information

ANTENNA PARTS CATALOG

ANTENNA PARTS CATALOG ANTENNA PARTS CATALOG Maco Antennas 302 S. East St. Mt. Carroll, IL 61053 www.macoantennas.net 815-244-3500 www.antennapartsoutlet.com SCREWS / BOLTS PART SIZE LENGTH DESCRIPTION PRICE S21 10-24 1/2" Machine

More information

CLEAR-DIVISIONS VARIOFOLD

CLEAR-DIVISIONS VARIOFOLD CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the

More information

NEMA Standards Publication VE 2-2000. Cable Tray Installation Guidelines

NEMA Standards Publication VE 2-2000. Cable Tray Installation Guidelines NEMA Standards Publication VE 2-2000 Cable Tray Installation Guidelines Published by: National Electrical Manufacturers Association 1300 North 17th Street Rosslyn, VA 22209 Approved by: Cable Tray Institute

More information

SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying cold-formed metal deck framing products and execution. The specifier needs to edit the guide

More information

BUILD A TABLETOP LOOM

BUILD A TABLETOP LOOM BUILD A TABLETOP LOOM From 1" x 2" stock (actual 3/4" x 1"1/2) cut: 4 pieces 15" long 4 pieces 5"1/2 long Use the above to make 2 frames for the front and back of the loom. From 1" x 4" stock (actual 3/4"

More information

I-Line. Accessories. Essential cable installation products for corrugated, smooth wall, and braided cables

I-Line. Accessories. Essential cable installation products for corrugated, smooth wall, and braided cables I-Line TM Essential cable installation products for corrugated, smooth wall, and braided cables Installation Coaxial cable installation components for corrugated, smooth wall and braided cables Proven

More information

Tubular connection elements

Tubular connection elements KIRÁY TRING KFT H-1151 udapest Mogyoród útja 12 14tel: 061307-3801 Tubular connection elements 429 KIRÁY TRING KFT H-1151 udapest Mogyoród útja 12 14tel: 061307-3801 Technical information on the tubular

More information

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12 SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications

More information

PUMP JACK SYSTEM AND ACCESSORIES

PUMP JACK SYSTEM AND ACCESSORIES Pump Jack Model # 2200 A low cost, easy to operate, safe, portable scaffolding built of rugged steel. It's perfect for shingling, siding, sheathing, insulating, painting, building, roofing, home repair

More information

By SP Partners, LLC. www.rainbowatticstair.com INSTALLATION GUIDE. Prestige

By SP Partners, LLC. www.rainbowatticstair.com INSTALLATION GUIDE. Prestige By SP Partners, LLC www.rainbowatticstair.com INSTALLATION GUIDE Prestige IMPORTANT READ THIS FIRST Inspect stair for any damage prior to installation. Stair is NOT to be installed while home is under

More information

Green Thread Product Data

Green Thread Product Data Green Thread Product Data Applications Dilute Acids Caustics Produced Water Industrial Waste Hot Water Condensate Return Materials and Construction All pipe manufactured by filament winding process using

More information

COMMERCIAL TYPE B GAS VENT MODEL E/V 10" 30"

COMMERCIAL TYPE B GAS VENT MODEL E/V 10 30 OMMERIL TYPE GS VENT MODEL E/V 10" 30" www.eccomfg.com GS VENT 10" 30" EO INDEX DESRIPTION... 90 E/V PIPE ND FITTINGS 10" Model... 91 12" Model... 91 92 14" Model... 92 16" Model... 93 18" Model... 93

More information

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET

More information

Section #1 Pictorial Table Of Contents. Material Strength. 25-2503 Profile. Page 662. Page 663. Phone: 260-248-8030 Fax: 260-248-8029 www.8020.

Section #1 Pictorial Table Of Contents. Material Strength. 25-2503 Profile. Page 662. Page 663. Phone: 260-248-8030 Fax: 260-248-8029 www.8020. How To Order 20-2020 Profile Section # Pictorial Table Of Contents Metric Part Naming Metric Page 639 Page 64 Page 642 Page 643 Page 644 Page 645 Pages 646-649 20 Series T-Slotted Aluminum Profiles 20-2040

More information

SECTION 230529 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION 230529 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 230529 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Steel pipe hangers and supports. 2. Metal framing systems. 3. Thermal-hanger shield inserts. 4. Fastener systems.

More information

Removable Aluminium posts

Removable Aluminium posts Post Solent Sail Shades Ltd 120 Billington Gardens Hedge End Southampton SO30 2RT Tel/Fax: 01489 788243 www.solentsailshades.co.uk Email: info@solentsailshades.co.uk Removable Aluminium posts Single Pole

More information

Connection Solutions

Connection Solutions Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction

More information

AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY. (The following code explanations are to be used with a copy of the 2011 NEC.

AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY. (The following code explanations are to be used with a copy of the 2011 NEC. AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY (The following code explanations are to be used with a copy of the 2011 NEC.) To obtain a copy of the NEC contact: National Fire Protection Association

More information

INSTRUCTIONS THOROUGHLY BEFORE BEGINNING***************

INSTRUCTIONS THOROUGHLY BEFORE BEGINNING*************** Bill of Materials: RAC0012 Green Wing Aerodynamic Skirt Kit Item Part Number Description Quantity 1 RMC0218 Gen 2 Trailer Skirt Roadside 1 2 RMC0219 Gen 2 Trailer Skirt Curbside 1 3 RMC0041 Trailer Skirt

More information

FRP Grating, Handrail, Guidelines for Ladders & the Engineer Structural and Designer Shapes

FRP Grating, Handrail, Guidelines for Ladders & the Engineer Structural and Designer Shapes Guidelines for the Engineer and Designer FRP Grating, Handrail, Ladders & Structural Shapes Corrosion Resistant Fire Retardant Low Maintenance Long Service Life High Performance Composite Solutions 1.0

More information

Series 4000 Fiberglass Pipe and Fittings

Series 4000 Fiberglass Pipe and Fittings Series 4000 Fiberglass Pipe and Fittings for corrosive industrial service Uses and applications Listings Performance Acid drains Chemical process piping Corrosive slurries Food processing Geothermal Nonoxidizing

More information

POST AND FRAME STRUCTURES (Pole Barns)

POST AND FRAME STRUCTURES (Pole Barns) POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:

More information

Aluminium Standard. Technical Data. Included in delivery

Aluminium Standard. Technical Data. Included in delivery luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:

More information

Guidelines for Earthquake Bracing Residential Water Heaters

Guidelines for Earthquake Bracing Residential Water Heaters Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev.

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev. Structural Bolting ASTM A325 and ASTM A490 are the two U.S. standard structural bolts. When looking at the mechanical requirements of bolts it appears that an ASTM A325 and SAE J429 Grade 5 are identical

More information

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2 ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES 1 PART 1 - GENERAL 1.0 GENERAL 1.1 REFERENCES: SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS

More information

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems: Reading Assignment SLAB DESIGN Chapter 9 of Text and, Chapter 13 of ACI318-02 Introduction ACI318 Code provides two design procedures for slab systems: 13.6.1 Direct Design Method (DDM) For slab systems

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

F-Series Camera Mounting Accessories

F-Series Camera Mounting Accessories F-Series Camera Mounting Accessories Document Number: 427-0462-00-12 Version: 100 Issue Date: September 2010 2010. All rights reserved worldwide. FLIR Commercial Systems, Inc. 70 Castilian Drive Goleta,

More information

The RIGHT SOLUTIONS for Canada s Oil and Gas Industry. T&B Cable Tray Systems

The RIGHT SOLUTIONS for Canada s Oil and Gas Industry. T&B Cable Tray Systems The RIGHT SOLUTIONS for Canada s Oil and Gas Industry T&B Cable Tray Systems What if you could get all the right solutions from one reliable Canadian source? Engineers, contractors and end-users working

More information

INDEX 02 : CABLE LADDERS

INDEX 02 : CABLE LADDERS 02-01 INDEX 02 : CABLE LADDERS Part No. Part No. Part No. Part No. Part No. ACS ORIGINALSTRUT ; CABLE LADDER - STEEL GENERAL INFORMATION LGBE8O0 02-11 LGTE8300 02-12 LGER80 02-13 LGLR5O450300 02-14 Cable

More information

SECTION 22 LIGHTNING PROTECTION SYSTEM

SECTION 22 LIGHTNING PROTECTION SYSTEM SECTION 22 LIGHTNING PROTECTION SYSTEM 22.01 SCOPE: A. These Specifications shall form a part of the Contract Documents and shall govern construction work for all buildings to be built or modified for

More information

Unpacking, Installation, and Customization

Unpacking, Installation, and Customization Unpacking, Installation, and Customization NetShelter WX Enclosure AR100 AR100HD Contents Unpacking... 1 How to Unpack the Enclosure............................... 1 Please Recycle..........................................

More information

Item #: BTOL Assembly Instructions

Item #: BTOL Assembly Instructions Item #: BTOL Assembly Instructions For our most current instructions, to request missing, lost or broken parts, or for any other Customer Service issues, please visit our website at www.walkeredison.com

More information