Tool Heaters and Temperature Controllers

Size: px
Start display at page:

Download "Tool Heaters and Temperature Controllers"

Transcription

1 Tool Heaters and Temperature Controllers

2 Tricool Thermal Advanced Engineering Tricool Thermal have been manufacturing high quality temperature control equipment for over 30 years. This amount of manufacturing experience has allowed us to grow in the UK and internationally; with distributors located throughout Europe and Asia. Our large production facility is based in Southampton, UK providing standard units for stock as well as fully customised solutions for all site requirements. Our experienced engineers utilise the latest 3D CAD technology to design the units which are manufactured in-house using the latest cellular production methods. With our flexible yet reliable approach, we have the ability to provide temperature control equipment to a wide variety of industries: Plastics Food & Beverage Medical Pharmaceutical Manufacturing & Process Chemical Cosmetic Printing & Laminating All our temperature control units are manufactured to ISO 9001 and ISO accreditations providing our customers with a high level of performance and quality. To view or download our ISO certificates please visit In addition to this, our Southampton production facility has a fully fitted test rig. We are one of the few companies in the UK to provide this facility and where required, customers are welcome to schedule a visit to view this in action. The test rig provides customers with reassurance that their equipment meets all performance ratings stated in Tricool literature. Built on Experience Tricool Engineering was formed First temperature controller developed and sold Tricool Engineering purchased UTAC Engineering to form the largest UK temperature controller manufacturer First temperature controller sold by international distributor Launched complete range of temperature controllers 2

3 Contents Tricool Thermal Explained page 2 Case Studies Experience Counts Glass and rubber industry page 4 Automotive and food industry page 5 Taking Control page 6 Features and Benefits page 7 The T90 Range page 9 T90: About the units Page 10 T90: Technical data page 11 T90: Pump capacity and schematics Page 12 The HTF Range page 14 HTF: About the units page 15 HTF: Technical data page 16 HTF: Pump capacity and schematics page 17 The P140 Range page 19 P140: About the units page 20 P140: Technical data page 21 P140: Pump capacity and schematics page 22 Tailor-Made Options page Relocation to new factory in Fareham Hampshire (20,000ft 2 ) Company moved into food market and explores other new areas for temperature control systems ICS Temperature Control Group acquired Tricool Engineering to combine their sales and marketing with Tricool s engineering Relocation to new site in Totton, Southampton (50,550ft 2 ) Tricool Thermal is now the manufacturing division of a 40 million organisation supplying temperature control equipment all over the world 3

4 Experience Counts The Glass Industry Requirement: To provide continuous and accurate temperature control for the process of float glass production for solar panels using line beams to maintain temperature levels. Raw materials are melted down together in a furnace at temperatures of up to 3000 o C producing a liquid compound. This is then run along a continuous belt in which line beams maintain its temperature; gradually cooling as it goes. Solution: We provided bespoke built dual circuit oil heaters with capacities of 200kW-400kW reaching temperatures of up to 260 o C. The dual circuit ensured continuous productivity even if a fault occured; allowing the line beams to maintain their exact temperature. These units were specifically designed to deliver consistently, very high temperatures with improved reliability. 18 different probes were fitted on the units to communicate with the customer s central computer system; monitoring for any faults 24/7. The Rubber Industry Requirement: To provide a packaged multi zone temperature control solution for the manufacture of tyres. Located overseas, the project required essential temperature control of a Banbury type mixer for the production and extrusion of rubber. Varied yet accurate temperatures were needed at each stage of the manufacturing process in order to produce the exact rubber compound. Solution: Having worked with the customer previously we had an understanding of their current process requirements, we were able to manufacture and supply 8 off 3-zone TCU s (temperature control units) and 4 off 4-zone TCU s. These compact, bespoke built multi zone T90 s with capacities of 9-96kW carry out the temperature control of 3-zones in one. They provide a more cost effective and practical solution whilst interfacing with the customer s main control panel using Profibus. With non-ferrous internal parts and self cleaning solenoid valves, maintenance and cleaning needs are reduced. The 4-zone TCU was adapted for temperature control of a larger extrusion machine, meeting all the particular design specifications. 4

5 Experience Counts The Automotive Industry Requirement: To provide temperature control equipment to a large car manufacturer in order to test the car engines. Heating and cooling equipment was required to simulate the temperatures of diesel fuel to ensure the engine worked safely at extreme conditions. Solution: Having worked closely with the customer we had a clear understanding of their requirements. Special HTF150 units were provided, which allowed the customer to set specific flow rates to match the diesel in order to gain accurate test readings. The Food Industry Requirement: To provide precision temperature control equipment to a large project-led engineering company based in High Wycombe Buckinghamshire. The company specialise in the manufacture of a wide range of finely tuned products that includes mixers, pressure vessels (BS550) jacketed vessels, blenders, dispensers and clean room equipment. Solution: Following an extensive brief, we designed and manufactured a custom-built 5kW thermoregulator to provide accurate temperature control. The unit circulates water through a closed circuit that maintains the temperature of the jacketed vessel s contents within a very tight tolerance. So far, we have supplied the customer with 45 systems and are confident that whatever the application we can be relied upon to provide the best solution to meet the customer s requirements. 5

6 Taking Control C7 Controllers Tricool Thermal units are available with C7 basic and C7 advanced controllers to manage process temperatures and ensure maximum productivity with no downtime. The C7 basic controller is featured on our range of e units; all other units are available with the C7 advanced controller. C7 Advanced Controller The C7 advanced controller has been developed for our thermoregulators to provide innovative technological temperature analysis. C7 Advanced Design development has been re-evaluated in order to provide the users with a more advanced system which is easy to navigate and can analyse processes in great detail; ensuring every aspect of the temperature and control is working to maximum productivity. C7 Advanced 6

7 Features and Benefits Features Benefits Basic Advanced Touch screen display Simple mobile smartphone navigation ü Full colour 3.5 TFT display Clear and easy to understand ü Text display No symbols or codes, clear text for alarms ü ü Modular Easily expandable ü Service due alarm Simple maintenance reminder ü Operating hours Number of running hours ü 7 day timer Switching on and off can be controlled via internal clock ü Security codes Operator, engineer and manufacturer access to ensure no unauthorised access: these can be configured on the advanced model Temperature limit values Programmable temperature alarms high and low ü ü Auto-tune cascade control Control of process using both remote and local probes ü Remote probe Sensing temperature from remote probe in process ü ü Selectable languages English, French, German, Spanish, Dutch, Swedish and Danish ü ü Ethernet interface Information can be sent via ethernet connection if required ü Analogue interfaces (external temperature input/output) Recipe control Information can be sent via 4-20mA signals ü ü Recipes can be created and saved for time, dwell and temperature set points Fully programmable Adjustable for all processes ü Flow monitoring The flow rate can be measured and displayed with limits and alarms ü Pressure monitoring The pressure can be measured and displayed with limits and alarms ü Automatic phase swap Ensures correct rotation of phases ü Data logging and trending on flow temperature and alarms Data is logged on micro SD card for evaluation of process when required Energy display Real time energy consumption can be displayed on screen ü ü ü ü Options Modbus RS485 Option for information to be sent via Modbus ü Profibus DP Option for information to be sent via Profibus ü Safety: Sensor failure monitor Hose rupture and leakage monitor Triple safety cut out for heating 7

8 8 The T90 Range

9 T90 Range T90e T90s T90m - Water up to 90 o C This range of modern temperature control equipment ensures temperatures are accurately managed within applications such as injection moulding, extrusion, rollers and vessels. These non-pressurised units deliver highly effective water heating with maximum reliability for long-life productivity. Additional advantages include: - Minimal rejection rates for improved production start-ups - Continuous high-quality production - Improved cavity-filling performance - Closer tolerances 9

10 T90 About the units Mechanical Direct acting self cleaning solenoid valves - Low maintenance due to minimal cleaning required Non-ferrous parts - All components exposed to water are made of nonferrous materials. Ensuring a long service life Stainless steel heat exchanger - More efficient with large gaps between plates which reduces the risk of blocking due to contamination Automatic and manual filling Castors Heating elements - Made of heat resistant alloy incoloy for high corrosion resistance and long service life High quality pump materials (no seal) Flow meter as standard (except for T90e-9/12) Pressure sensors (except for T90e-9/12) Inlet/outlet temperature sensors (except for T90e-9/12) Leak stopper Tank made of stainless steel - Ensuring a long service life Electric and control equipment Solid state relays - Energy savings due to pulsing every 0.3 seconds (contactors generally every 16 seconds) proving increased accuracy Diagnostic controller - Improves maintenance by showing knowledge of any faults that occur C7 basic with diagnostic control for T90e models C7 advanced standard on T90s and T90m - see page 6 Available Options: - Connections for various analogue and digital electric interfaces - Remote probe for cascade control - Stainless steel panels - Increased cooling 10

11 Technical Data T90 Equipment T90e T90s T90m Control system C7 ü - - Control system C7 advanced - ü ü Solid state relay ü ü ü Electronic flow measurement - ü ü Bypass for regulation of the flow rate in the process - ü ü Leak-free pump ü ü ü Water circuit of non-ferrous materials ü ü ü Automatic water refill ü ü ü Unit in IP54 protection degree ü ü ü Technical Data T90e T90e T90s T90s T90s T90m T90m T90m Outlet temperature: o C Heat transfer fluid: Water Water Water Water Water Water Water Water Nominal capacity: Litres Filling quantity: Litres Expansion volume: Litres 2* 2* 2* 2* 2* 4* 4* 4* Maximum external volume: Litres Heating capacity: kw Cooling capacity: kw At outlet temperature with 20 o C cooling water inlet temperature o C Pumping capacity data: Flow rate: lpm Pressure: bar Control: Measuring mode: (std.) Solid State Relay PT100 Operating voltage: (std.) v-ph-hz E Connections: Process flow return: - G½ G¾ G¾ G¾ G¾ G1 G1 G1 Coolant inlet/outlet: - G¼ G¼ G½ G½ G½ G½ G½ G½ Dimensions: Length: mm Width: mm Height: mm Weight: kgs Colour: RAL7035/RAL3020 Ambient temperature: o C 40 Noise level: db(a) <70 Notes: *The expansion volume allowed within the tank design has been based on the stated Maximum External Volume and the process fluid is being heated from 15 o C to 90 o C 11

12 T90 Pump Capacity T90s - 9 T90s - 12 T90s - 18 T90e - 9 T90e DELIVERY HEAD (m) T90e DELIVERY HEAD (m) T90s FLUID FLOW (LPM) 10 T90m - 24 T90m - 32 T90m FLUID FLOW (LPM) 50 DELIVERY HEAD (m) T90m FLUID FLOW (LPM) T90 Schematics T90e T90s & T90m 12

13 TheHTFRange 13

14 HTF Range HTF150 HTF250 HTF350 - Oil heaters from 150 o C to 350 o C This range of robust heater units work at a wide variety of capacities from 9-48kW providing consistent high temperatures without pressurisation. Units within this range provide the perfect temperature control consistency for the following processes: - Plastics Extrusion - Die Casting - Injection Moulding - Food Production - Chemical and Pharmaceutical - High Temp Jacketed Vessels In the production of die casting, temperature control units can reduce reject rates up to 80% and make the die last up to three times longer; reducing heat up time by as much as 30%. 14

15 HTF About the units C7 basic with diagnostic control for HTFe models C7 advanced standard on HTFs and HTFm - see page 6 Non-ferrous parts - All components exposed to water are made of nonferrous materials ensuring a long service life Solid state relays - Reduces energy usage due to pulsing every 0.3 seconds (contactors generally every 16 seconds). Offers increased accuracy and with no moving parts eliminates wear and tear Stainless steel heat exchanger - Gaps between the plates reduce the risk of blocking Direct acting self cleaning solenoid valves - With no diaphragm this helps reduce the maintenance needed, due to the minimal manual cleaning required Large volume tank on the HTF150 s - More stable temperatures can be achieved Magnetic drive pump as standard (except for HTF150e) - Seal-less so low maintenance alleviates any leaks Bypass for internal circulation of the oil - In case of insufficient flow. Avoids thermal overloading of the oil Seperate expansion vessel - Reduces oxidation as the circulating oil is seperated from the atmosphere by the stationery oil in the expansion tank 3-way valve - On temperature control side, standard on units HTF350, optional HTF250 units. Eliminates thermal shocking of the heat exchanger, ensuring a long service life Available Options: - Connections for various analogue and digital electric interfaces - Remote probe for cascade control - Stainless steel panels - Increased cooling - 3-way valve bypass on the temperature control side fitted on HTF250 (standard on HTF350) 15

16 Technical Data HTF Equipment HTF150 HTF250 HTF350 Control system C7 ü - - Control system C7 advanced - ü ü Solid state relay ü ü ü 3-way valve on temperature control side - Optional ü Electronic flow measurement - Optional ü Mag Drive Pump - ü ü Technical Data HTF150e HTF250e HTF250s HTF350s HTF250m HTF350m Outlet temperature: o C Heat transfer fluid: Oil Oil Oil Oil Oil Oil Nominal capacity: Ltrs Filling quantity: Ltrs Expansion volume: Ltrs 9 12* 12* 27** 27** 51** Maximum external volume: Ltrs Heating capacity: kw 9/ Cooling capacity: kw / /220 At outlet temperature with 20 o C cooling water inlet temperature o C Pumping capacity data: Maximum flow rate: lpm Maximum delivery head: Control: Measuring mode: (std.) bar Solid State Relay PT100 Operating voltage: Connections: v-ph- Hz E Process flow return: - G½ G1 G1 G1 DN32 *** DN50 *** DN50 *** Coolant inlet/outlet: - G½ G½ G½ G½ G½ G½ /G¾ G½ /G¾ Dimensions: Length: mm Width: mm Height: mm Weight: kgs Colour: RAL7035/RAL3020 Operating temperature: o C 40 Noise level: db(a) <70 Notes: *The expansion volume allowed within the tank design has been based on the stated Maximum External Volume and assuming the Process Fluid is being heated from 20 o C to 250 o C. **The expansion volume allowed within the tank design has been based on the stated Maximum External Volume and assuming the Process Fluid is being heated from 20 o C to 350 o C. 16

17 HTF Pump Capacity HTF250s - 9 & HTF250s - 12 HTF350s - 9 & HTF350s - 12 HTF250e - 9 HTF250s - 18 & HTF250s - 24 HTF350s - 18 & HTF350s - 24 HTF250m - 48 & HTF350m - 48 HTF250m DELIVERY HEAD (m) HTF250/HTF FLUID FLOW (LPM) DELIVERY HEAD (m) HTF150e HTF150e - 9 HTF150e FLUID FLOW (LPM) 80 0 HTF Schematics HTF250 HTF350 17

18 18 TheP140Range

19 P140 Range P140e P140s P140m - Water up to 140 o C These pressurised units deliver high temperature water heating with limited need for maintenance and offer increased energy efficiency. Capacities range from 9-48kW, with water temperatures reaching up to 140 o C. - Plastics/Injection Moulding - Food Production Processes - Chemical and Pharmaceutical The unit features an air bottle, stainless steel heat exchanger, pressure sustaining accumulator, nonferrous internal parts, low tank volume and solid state relays. The unit also features an auto shutdown system to prevent any leaks. 19

20 P140 About the units C7 basic with diagnostic control for P140e models C7 advanced standard on P140s and P140m - see page 6 Non-ferrous parts - All components exposed to water are made of nonferrous materials ensuring a long service life Pressure sustaining accumulator - Operating temperature independent of cooling water pressure - flexible operation Direct acting self cleaning solenoid valves - Low maintenance due to minimal cleaning required (no diaphragm) Heating elements - Made of heat resistant alloy incoloy for high corrosion resistance and long service life Auto shutdown system - If a pipe breaks the machine will stop and lock the supply water system down to prevent any leaks Air release bottle - Protects the heating elements and pump where large amounts of air could be present in the process Available Options: - Direct cool - Increased cooling - Stainless steel panels - Remote probe for cascade control - Connections for various anologue inputs & outputs 20

21 Technical Data P140 Equipment P140e P140s P140m Control system C7 ü ü - Control system C7 advanced - ü ü Solid state relay ü ü ü Electronic flow measurement - ü ü Display of outlet pressure - ü ü Leak-free pump - Optional Optional Pressure gauge for outlet pressure ü ü ü Technical Data P140e P140s P140s P140m Outlet temperature: o C Heat transfer fluid: Water Water Water Water Heating capacity: kw 9/12 9/12 18/24 24/36/48 Cooling capacity: kw At outlet temperature with 20 o C cooling water inlet temperature o C Pumping capacity data: Flow rate: lpm Pressure: bar Control: Measuring mode: (std.) Solid State Relay PT100 Operating voltage: (std.) v-ph-hz E Connections: Process flow return: - G½ G½ G1 G1¼ Coolant inlet/outlet: - G½ G½ G½ G½ Dimensions: Length: mm Width: mm Height: mm Weight: kgs Colour: RAL7035/RAL3020 Ambient temperature: o C 40 Noise level: db(a) <70 21

22 P140 Pump Capacity P140e - 9 & P140e - 12 P140s - 9 & P140s - 12 P140s - 18 & P140s DELIVERY HEAD (m) P140e/P140s DELIVERY HEAD (m) P140s FLUID FLOW (LPM) FLUID FLOW (LPM) 50 P140m - 24 & P140m - 36 & P140m - 48 DELIVERY HEAD (m) P140m FLUID FLOW (LPM) P140 Schematics 22

23 Tailor-Made Options Having carried out numerous projects for a variety of applications around the world our engineering team are experienced in a wide variety of applications. Exclusively dealing with customer specific systems our engineering team is a competent partner in the design, development, configuration and implementation of customised technology for challenging and complex tasks. We can provide tailor-made special systems and system solutions with a keen price/ performance ratio. 1 - Special construction and dimensions 2 - Voltages and temperatures 3 - Flow rates and pressures 4 - Controller specific special applications and function We can manufacture customised equipment to suit specific requirements and provide a variety of control options. Our systems can communicate with higher level machines or line controls via a wide range of different electronic interfaces. Units are available with or without a controller which allows integration into the customers own control specific environment. OEM Manufacturing We are a preferred partner of many machine manufacturers and processors providing solutions for temperature control systems and compact integrated temperature control systems. These systems are for integration into the OEM s machinery and equipment is configured to meet the customer s application requirements. Temperature control technology is integrated as a system component into machinery for plastics, food and pharmaceutical processing in plant engineering applications. Market specific temperature controllers Major injection moulding and other industrial suppliers often operate with modular, multi circuit temperature control systems. Our units feature a particularly small footprint which can be configured to suit customer specific special components or customer specific flow rates and cooling/heating conditions. In the food and pharmaceutical industry, stainless steel panels are often required with suitable IP rated controllers as well as chart recorders and trending. With a wealth of experience in this area, we offer standard stainless steel panels with suitable PLCs. 23

24 Contact us Group Companies Head Office South ICS House Stephenson Road Calmore Industrial Estate Totton, Southampton SO40 3RY FREEPHONE T +44 (0) F +44 (0) ICS Service 24/7 Nationwide Support Emergency Breakdown

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES

More information

Refrigeration Compressed Air Dryer Buran Ultrapulse

Refrigeration Compressed Air Dryer Buran Ultrapulse Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of

More information

PLC Based Liquid Filling and Mixing

PLC Based Liquid Filling and Mixing PLC Based Liquid Filling and Mixing 1 Mihir Panchal, 2 Aashish Panaskar. 3 Prof. Lalit Kumar KJ College of Engineering and Management Research, Pune, India Abstract: The objective of this paper is to design,

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm

4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm The Perkins 4000 Series family of 6, 8, 12 and 16 cylinder diesel engines was designed in advance of today s uncompromising demands within the power generation industry and includes superior performance

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Hot Water. Heat pump water heaters. Residential and Commercial R410a Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Engineered Solutions

Engineered Solutions Engineered Solutions Long established partnerships bring together the world s leading instrumentation companies within BKW. Our manufacturing facility enables us to quickly adapt standard instruments to

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

Freezers - Ultrafreezers. Platilab & Irilab Series

Freezers - Ultrafreezers. Platilab & Irilab Series Freezers - Ultrafreezers Platilab & Irilab Series PLATILAB: top security and performances with reliable temperature control. IRILAB: combining the high reliability of PLATILAB with the possibility to store

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1 Fault codes DM1 Industrial engines DC09, DC13, DC16 Marine engines DI09, DI13, DI16 03:10 Issue 5.0 en-gb 1 DM1...3 Abbreviations...3 Fault type identifier...3...4 03:10 Issue 5.0 en-gb 2 DM1 DM1 Fault

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

Cooling Channel Optimization

Cooling Channel Optimization Mouldflo Test Rig Cooling Channel Optimization Plug and Play Mould pre-set for production For the first time Mouldflo offers Mouldmakers a unique way to configurate the cooling circuits with full Benchmark

More information

OT 40L / 90L. Laboratory Steam Sterilizers

OT 40L / 90L. Laboratory Steam Sterilizers OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture

More information

globe reactions made easy Process perfection

globe reactions made easy Process perfection globe reactions made easy Process perfection Benefits More reactions in less time: The Globe oil drain unit and quick clamp allow single hand vessel changes in seconds Space saving: 50ml, 100ml, 250ml,

More information

ThermoStar Refrigeration Air Dryers

ThermoStar Refrigeration Air Dryers ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems

More information

Diagram of components 2. Reducer..3

Diagram of components 2. Reducer..3 Index Diagram of components 2 Reducer..3 Rail Filter - Rail Filter 4 - MAP Sensor.4 Injector & Nozzle - Single Injector / Rail Injector...5 - Bi-Fuel Connector...6 - Nozzle...7 ECU...8 Switch 9 Wiring

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range

More information

DIESEL FUEL CONDITIONING

DIESEL FUEL CONDITIONING COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency

More information

In-Line Electronic Flow Switches

In-Line Electronic Flow Switches In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Alfa Laval PureBallast 3.1

Alfa Laval PureBallast 3.1 Alfa Laval PureBallast 3.1 Ballast water treatment system 1000 m 3 /h system Alfa Laval PureBallast 3.1 is an automated inline treatment system for the biological disinfection of ballast water. Operating

More information

Intelligent Mould Flow Monitoring

Intelligent Mould Flow Monitoring Intelligent Mould Flow Monitoring The Mouldflo Flow Monitoring System 1 2 The Mouldflo Flow Monitoring System Mouldflo Flow Monitoring System For the first time Mouldflo offers Injection Moulders an affordable

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions Mounting and operating instructions CONTOIL DFM 8EDM Table of contents Safety instructions 2 - Designed use - Installation, commissioning and operation - Operational safety - Return of the instruments

More information

In-Line Electronic Flow Switches

In-Line Electronic Flow Switches In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems 185, 600, 1200, 1800, 2700 Series Portable Purification Systems FEATURING Global Filtration Technology PRINCIPLES OF OPERATION Contaminated oil is drawn into the Parker Portable Purification System by

More information

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions The world s best selling supply unit. The right choice for any conditions AB-c arine Compact Heavy Fuel Oil supply unit This series of marine AB-c Heavy Fuel Oil () supply units is developed to combine

More information

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB. Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier

More information

ThermoSorb Desiccant Dryers

ThermoSorb Desiccant Dryers ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression

More information

Process Alarm Solutions

Process Alarm Solutions Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical

More information

Atlas Copco Generators

Atlas Copco Generators Atlas Copco Generators QIX 15 - QIX 540 16 kva LTP to 549 kva LTP at 50 & 60 Hz The QIX options include Earth leakage relay Qc generating set control panels for all standby and/or paralleling applications

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

The 26 200 kva RAnge

The 26 200 kva RAnge The 26 200 kva Range The new 26 200 kva range...designed to Deliver More. We understand the unique needs of generating set customers around the world. Forty years experience combined with the latest technology

More information

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel

More information

Sanitary Type Electronic Flow Switches

Sanitary Type Electronic Flow Switches Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Why and How we Use Capacity Control

Why and How we Use Capacity Control Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,

More information

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 50HZ MP Series MPS180S 1 / MPS180 1 MPS180S 1 / MPS180 1 MP Series Features Compact structure with high strength chassis; Easy operation and maintenance,

More information

INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016. www.elipse-automation.eu

INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016. www.elipse-automation.eu INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016 Your partner in an automated industry Our combination of technical know-how, product responsibility and on-time deliveries guarantees you the best WHY CHOOSE

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system

More information

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps P/N: DEF-0613A Diesel Exhaust Fluid (DEF) Pumps DEF Solutions Standard Pump has designed a range of unique, preconfigured DEF Pump Packages that are engineered to transfer AdBlue (AUS32) Diesel Exhaust

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

How To Use A Corona Mdi 110

How To Use A Corona Mdi 110 CORONA MDI 110 APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise! Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals

More information

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL FUEL CONSUMPTION MEASUREMENT AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL Description The combination of AVL Fuel Mass Flow Meter and AVL Fuel Temperature Control is a high precise and continuous

More information

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air

More information

PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS

PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS I N S P I R E D E F F I C IEN C Y PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS INSPIRED EFFICIENCY Mikrofill Systems Ltd is a Midlands based British

More information

* Shown with #D041 Airpot dispenser (sold separately)

* Shown with #D041 Airpot dispenser (sold separately) The 3 Liter CBS-23 / 232 Touchscreen Series Airpot Coffee Brewers are a perfect hot beverage solution for high volume self-service environments such as convenience stores, cafeterias, specialty coffee

More information

Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit

Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit Oil-Free Screw Compressors Water-injected Technology Rely on GD to provide the perfect fit Why oil-free? Don t compromise on quality If 100% clean and oil-free compressed air is a requirement for your

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance VTS³ and VCS³ Stress Screening Systems More Power for Maximum Quality Assurance Tailor-made for your product: Our proven testing methods Thermal and climatic conditions can affect the production, storage

More information

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps (20-100 GPM) 10 to 34 KW Stainless Steel Heaters

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps (20-100 GPM) 10 to 34 KW Stainless Steel Heaters Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons

More information

4.0 UPS dedicated to ICT for unmatched energy savings

4.0 UPS dedicated to ICT for unmatched energy savings 4.0 UPS dedicated to ICT for unmatched energy savings Introducing UPSaver by Borri, a new modular UPS series for the ICT industry, totally configurable, quickly scalable, with high efficiency and low TCO.

More information

LyoBeta. R+D Freeze-Dryers

LyoBeta. R+D Freeze-Dryers LyoBeta R+D Freeze-Dryers LyoBeta series A Responsible Choice New demands in R+D centers are related to scale-up feasibility and quality of procedures and research methods. FDA investigators consider that

More information

Split Controller. User Manual SM-SS-F 2009/01/04

Split Controller. User Manual SM-SS-F 2009/01/04 Split Controller SM-SS-F User Manual 2009/01/04 Table of contents 1. Parts illustration.... 1 2. Electrical technical data...... 2 3. Electrical connection...3 4. Assemble parts...4 4.1 Assemble the fixed

More information

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw ,QGXVWULDO#*HQHUDWRU 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw Generator set consisting of engine and alternator mounted

More information

Why a torque measuring system?

Why a torque measuring system? T-Sense P R O D U C T B U L L E T I N 660 Optical Torque Measuring Systems Introduction The use of a T-Sense torque measuring system means efficiency improvement, overload protection and prevention of

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

industry revolves around

industry revolves around revolves around innovation Throughout its 50 year history Hydrovane has been the market leader in rotary vane compression technology, building an enviable reputation for quality and reliability. As part

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store

More information

Marine after-treatment from STT Emtec AB

Marine after-treatment from STT Emtec AB Marine after-treatment from STT Emtec AB For Your Vessel and the Environment SCR Technology How it works The selective catalytic reduction of nitrous oxides (NOx) by nitrogen compounds such as urea solutions

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts; 1/11 CO2 DOSAGE SYSTEMS CO2 dosage system consists of following parts; 1 - O2 trim system with micro processing burner (automatic combustion monitoring), 2 - Other components of O2 trim system, 3 - CO2

More information

AIRROLLAIR COMPRESSORS 15-20 - 25-30 - 40E

AIRROLLAIR COMPRESSORS 15-20 - 25-30 - 40E AIRROLLAIR COMPRESSORS 15-20 - 25-30 - 40E ROLLAIR 15-40E: INCREASED FLEXIBILITY IN AN EXTENDED RANGE Worthington Creyssensac cares for future generations and is an ISO 14000 certified manufacturing company

More information

FVA/A1 saturated-steam sterilizer

FVA/A1 saturated-steam sterilizer FVA/A1 where technology innovation and design come together FVA/A1 saturated-steam sterilizer www.fedegariautoklaven.ch Fedegari's new FVA/A1 series of automatic vertical sterilizers has been expressly

More information

Commercial Hot Water. Make a difference...

Commercial Hot Water. Make a difference... Commercial Hot Water Make a difference... heat S O L A R pumps The Company Quantum Energy Technologies The Quantum story is based on innovation and the quest to harness renewable energy to produce sustainable

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

How is Dew Point Measured Reliably?

How is Dew Point Measured Reliably? How is Dew Point Measured Reliably? Air compression increases vapor pressure and thus dew point. = water vapor Vapor pressure Frost point Saturation - 0 C + Dew point Monitoring with alarming and real

More information

Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions.

Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions. Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions. Our equipment, systems and services are dedicated to helping customers to optimize the performance

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

Top Technology for Industry, Agriculture, Business and Communities

Top Technology for Industry, Agriculture, Business and Communities Top Technology for Industry, Agriculture, Business and Communities CHP The Technology with a Potential for Saving Energy Combined Heat and Power (CHP) is a highly efficient technology for the conversion

More information

www.optimumheat.co.uk

www.optimumheat.co.uk The modern wood pellet boiler with built-in flexibility and remote fingertip control Up to 98% efficient Wide output range Simple touch-panel control Remote control & maintenance Extremly low emissions

More information

Waste Oil Handling, Spill Containment & Lighting

Waste Oil Handling, Spill Containment & Lighting 58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20

More information

COMBIMASS. Technical Data COMBIMASS eco-bio +

COMBIMASS. Technical Data COMBIMASS eco-bio + COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information