Price List Malleable Pipe Fittings
|
|
- Jonas McLaughlin
- 7 years ago
- Views:
Transcription
1 Price List Malleable Pipe Fittings LT-MPF0714 EFFECTIVE DATE: JULY, 2014 SUPERSEDES MAY 1, 201 PRICE LIST It's all about performance
2 ORDERING INSTRUCTIONS SA and China malleables use the same list with different multipliers SA Thailand Chinese Fittings You Part number have only, a different no suffix multiplier Multiplier which is Part applicable number with to addition the Chinese of C suffix fittings. Multiplier 1/2 Black 90 Elbow /2 Black 90 Elbow 0-00C When ordering Chinese fittings, simply add suffix C to the six digit item number. 90 Elbows Effective Date July, Size Part No. List Price Part No. List Price Cs Ct 1/ / / / / / / / Elbows 1/ / / / / / / / Reducing Elbows 1/4 x 1/ /8 x 1/ /2 x 1/ /2 x / /4 x 1/ /4 x / /4 x 1/ x 1/ x / /4 x 1/ /4 x / /4 x /2 x 1/ /2 x / /2 x /2 x 1-1/ x 1/ x / x x 1-1/ x 1-1/ /2 x 1-1/ /2 x x x 2-1/ x
3 You have a different multiplier which is applicable to the Chinese fittings. When ordering Chinese fittings, simply add suffix C to the six digit item number. 90 Street Elbows Effective Date July, Size Part No. List Price Part No. List Price Cs Ct 1/ / / / / / / / Street Elbows 1/ / / / / / / / Side Outlet Elbows 1/ / Tees 1/ / / / / / / /
4 You have a different multiplier which is applicable to the Chinese fittings. When ordering Chinese fittings, simply add suffix C to the six digit item number. Reducing Tees Effective Date July, Size Part No. List Price Part No. List Price Cs Ct 1/2 x 1/ /2 x / /4 x 1/ /4 x / /4 x 1/ x 1/ x / x 1/ x / /4 x 1/ /4 x / /4 x /2 x 1/ /2 x / /2 x /2 x 1-1/ x 1/ x / x x 1-1/ x 1-1/ /2 x x x 1-1/ x 1-1/ x x x /4 x 1/2 x 1/ /4 x 1/2 x / /4 x 1/2 x x 1/2 x 1/ x 1/2 x / x 1/2 x x /4 x 1/ x /4 x / x /4 x /4 x 1/2 x /4 x 1/2 x 1-1/ /4 x /4 x 1/ /4 x /4 x / /4 x /4 x /4 x /4 x 1-1/ /4 x 1 x 1/ /4 x 1 x / /4 x 1 x /4 x 1 x 1-1/ /4 x 1 x 1-1/ /2 x /4 x 1-1/ /2 x 1 x /2 x 1 x 1-1/ /2 x 1-1/4 x /2 x 1-1/4 x 1-1/ /2 x 1-1/4 x 1-1/ x 1/2 x x 1 x x 1-1/4 x 1-1/ x 1-1/2 x x 1-1/2 x 1-1/ x 1-1/2 x 1-1/
5 You have a different multiplier which is applicable to the Chinese fittings. When ordering Chinese fittings, simply add suffix C to the six digit item number. Bull Head Tees Effective Date July, Size Part No. List Price Part No. List Price Cs Ct Side Outlet Tees 1/2 x 1/2 x / /2 x 1/2 x /4 x /4 x /4 x /4 x 1-1/ x 1 x 1-1/ x 1 x 1-1/ x 1 x /4 x 1-1/4 x 1-1/ /4 x 1-1/4 x /2 x 1-1/2 x x 2 x 2-1/ / / Crosses 1/ / / / / / / Square Head Plugs 1/ / / / / / / /
6 You have a different multiplier which is applicable to the Chinese fittings. When ordering Chinese fittings, simply add suffix C to the six digit item number. Unions Effective Date July, Size Part No. List Price Part No. List Price Cs Ct 1/ / / / / / / / Caps 1/ / / / / / / / Banded Couplings 1/ / / / / / / / Reducing Couplings 1/4 x 1/ /8 x 1/ /8 x 1/ /2 x 1/ /2 x 1/ /2 x / /4 x 1/ /4 x 1/ /4 x / /4 x 1/
7 You have a different multiplier which is applicable to the Chinese fittings. When ordering Chinese fittings, simply add suffix C to the six digit item number. Reducing Couplings continued Effective Date July, Size Part No. List Price Part No. List Price Cs Ct 1 x 1/ x / x 1/ x / /4 x 1/ /4 x / /4 x /2 x 1/ /2 x / /2 x /2 x 1-1/ x 1/ x / x x 1-1/ x 1-1/ /2 x /2 x 1-1/ /2 x 1-1/ /2 x x x 1-1/ x 1-1/ x x 2-1/ x x 2-1/ x x x Hex Bushings 1/4 x 1/ /8 x 1/ /8 x 1/ /2 x 1/ /2 x 1/ /2 x / /4 x 1/ /4 x 1/ /4 x / /4 x 1/ x 1/ x / x 1/ x / /4 x 1/ /4 x / /4 x 1/ /4 x / /4 x /2 x 1/ /2 x 1/ /2 x / /2 x /2 x 1-1/ x 1/ x / x
8 You have a different multiplier which is applicable to the Chinese fittings. When ordering Chinese fittings, simply add suffix C to the six digit item number. Hex Bushings continued Effective Date July, Size Part No. List Price Part No. List Price Cs Ct 2 x 1-1/ x 1-1/ /2 x 1/ /2 x / /2 x /2 x 1-1/ /2 x 1-1/ /2 x x x 1-1/ x 1-1/ x x 2-1/ /2 x x x 2-1/ x x x x Floor Flanges 1/ / / / NOTE: PLEASE SEE SEPARATE SHEET FOR MERCHANT COUPLINGS All fittings are UL Listed & FM approved for fire suppression. All galvanized fittings are third party certified no lead ANSI/NSF-72. Legend Valve malleable fittings are boxed in sturdy corrugated inner cartons with detailed description, color-coded label, and UPC bar code. Although you do not have to adhere to inner carton quantities when ordering, productivity studies have revealed that for sizes 2 and under, it has been proven to be advantageous for you to do so. LT-MPF0714 LT-MPF N. Opdyke Rd. Auburn Hills, MI 4826 phone: fax: web: service@legendvalve.com 7
9 Price List Black and Galvanized Pipe Nipples BGN-0216 EFFECTIVE DATE: FEB. 1, 2016 SUPERSEDES JUNE 1, 2012 PRICE LIST
10 1 Please order in carton quantities where possible. Effective Date: FEBRUARY 1, black steel pipe nipples black steel pipe nipples list, item number and carton quantity Diameter Inches Length in Inches Close 1-1/ /2-1/ /2-1/ / / / / / / / / Grid Code: List Price Item Number Carton Quantity
11 black and galvanized pipe nipples Effective Date: FEBRUARY 1, Nipple Assortment Packs Part No. Size List Price Case Qty. ASSORENT - PACK / / Pack ASSORENT - 66 PACK / / / ASSORENT - PACK / / ASSORENT - 66 PACK / / / Nipple Runs Nipple Run STANDARD NIPPLE RUNS -6 1/2 CLO /4 CLO CLO /4 CLO /2 CLO CLO STANDARD NIPPLE RUNS 6-6 1/2 CLO /4 CLO CLO /4 CLO /2 CLO CLO Oil Tank Leg Oil Tank Leg OIL TANK LEGS /4 x /4 x /4 x /4 x /4 x /4 x
12 galvanized steel pipe nipples 2 Effective Date: FEBRUARY 1, galvanized steel pipe nipples list, item number and carton quantity Diameter Inches Length in Inches Close 1-1/ /2-1/ /2-1/ / / / / / / / / Please order in carton quantities where possible. Grid Code: List Price Item Number Carton Quantity
13 AND cut-lengths Effective Date: FEBRUARY 1, CUT-LENGTH PIPE cut-length pipe list, item number and bundle quantity Diameter Inches Diameter Inches black Length in Inches Length in Inches Diameter Inches galvanized Length in Inches / / / / / / / / Black Cut-Length Pipe Part No. Size List Price Bundle Qty /2 x /2 x /2 x Cut Pipe Rack Part No. Size List Price Case Qty. -40 L=22.7 x D=18. x H= 2 $ 1, Assembly Required. Please order in carton quantities where possible. Grid Code: List Price Item Number Carton Quantity
14 00 N. Opdyke Rd. Auburn Hills, Michigan 4826 phone: (800) fax: (800) web: LT-BGN0216
Plumbing Lesson Five: Pipe Fittings and Parts. Student Handouts
Lesson Five: Pipe Fittings and Parts Student Handouts Building Basics was paid for under an EL Civics grant from the U. S. Department of Education administered by the Virginia Department of Education.
More informationTransport & Automotive CATALOGUE. March 2011. Customer Service Phone: 1800 777 299 Fax: 1800 065 321 Email:sales@tubefit.com.au. www.tubefit.com.
Transport & Automotive CATALOGUE Customer Service Phone: 1800 777 299 Fax: 1800 065 321 Email:sales@tubefit.com.au March 2011 www.tubefit.com.au Page 1 4 6 9 12 14 16 17 19 20 22 23 24 26 28 29 31 33 Index
More informationBased on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013
SimplexGrinnell TXMAS ecommerce Ferguson Fire and Fabrication Sprinkler Price List Based on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013 Product ID Description TXMAS
More informationPlumbing Lesson Five: Pipe Fittings and Parts. Facilitator Guide
Lesson Five: Pipe Fittings and Parts Facilitator Guide Building Basics was paid for under an EL Civics grant from the U. S. Department of Education administered by the Virginia Department of Education.
More informationSYSTEM PLUMBING KIT INSTALLATION, OPERATION & SERVICE MANUAL. PENTAIR POOL PRODUCTS CORPORATE OFFICE Sanford, NC (919) 775-4151
TANDEM SYSTEM PLUMBING KIT INSTALLATION, OPERATION & SERVICE MANUAL PENTAIR POOL PRODUCTS CORPORATE OFFICE Sanfd, NC (919) 775-4151 PENTAIR POOL PRODUCTS Mopark, CA (805) 523-2400 TANDEM SYSTEM PLUMBING
More informationSYSTEM PLUMBING KIT INSTALLATION, OPERATION & SERVICE MANUAL. PENTAIR POOL PRODUCTS CORPORATE OFFICE Sanford, NC (919) 566-8000
TANDEM SYSTEM PLUMBING KIT INSTALLATION, OPERATION & SERVICE MANUAL PENTAIR POOL PRODUCTS CORPORATE OFFICE Sanfd, NC (99) 566-8000 PENTAIR POOL PRODUCTS Mopark, CA (805) 53-00 P/N 599 REV. A TANDEM SYSTEM
More informationStainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
More informationPARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM
PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM RELIANCE Has Everything Your Customers Need to Do the Job Right! Reliance Water Heater Company was founded in 1981 to provide a water heater
More informationHose Clamps & Fittings
All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw
More informationNOTE: All orders are accepted on the basis of prices in effect at the time of shipment.
FORGED CARBON STEEL FITTINGS & FORGED STEEL UNIONS Screwed and Socket Welding Price Sheet CSF-4.11 Effective: April 18, 2011 Cancels Price Sheet CSF-1.09 & U-1.09 of January 26, 2009 FOR THE MOST CURRENT
More informationNumber Wheeler P/N Description Set Rex P/N Notes
1 604041 Base 1 4041 2 604042 Base Cover 1 4042 3 608849 Washer (M5) 2 4 600124 Spring Washer (M5) 2 5 600329 Rd Hd Machine Screw (M5x8) 2 6 604047 Strainer 1 4047 7 600204 Rd Hd Machine Screw (M6x10)
More informationNFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code
Part 1 - GENERAL 1.1 DESCRIPTION OF WORK A. Design and installation of an engineered Kidde ECS Advanced Delivery Systems (ADS), clean agent/waterless fire suppression system employing DuPont FM-200 agent,
More informationPipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
More informationFire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
More informationHow To Maintain A Gardner Dianner Pump
GARDNER DENVER 3-1-541 Rev D April, 2005 HD-2250 WELL SERVICE PUMP POWER END PARTS LIST ECN 1025185 MAINTAIN PUMP RELIABILITY AND PERFORMANCE WITH GENUINE GARDNER DENVER PARTS AND SUPPORT SERVICES Gardner
More informationUNIVERSAL 1550 PRE-MIX DISPENSER
MODEL NO. 284974xxx 1 of 8 Control Code A ªIMI Cornelius Co., 1987-95 22 5 6 2 3 7 4 1 26 32 19 28 33 29 27 11 15 18 16 17 14 9 31 30 34 24 20 23 8 10 21 13 FIGURE 1. ASSEMBLY ªIMI Cornelius Co., 1987-95
More informationFittings Trade Net Price Sheet - US
Steel Conduit - - Galvanized RMC Nipples RMC Elbows RMC Running Thread Pipe Yard Light Elbows Aluminum Conduit Nipples Elbows Couplings Electrical Metallic Tubing -- Galvanized Elbows Fittings Net Price
More informationElbows, Couplings & Nipples (EC&N)
Elbows, Couplings & Nipples (EC&N) The trusted name in steel North America s Best-in-Class Electrical Elbows, Couplings & Nipples for more than 135 years. Established in 1877, Wheatland Tube is the longest-running
More informationMÁQUINAS AGRÍCOLAS JACTO S.A. EDITION
AJ English version EDITION - 06/007 CODE - 9790 Parts catalog MÁQUINAS AGRÍCOLAS JACTO S.A. Rua Dr. Luiz Miranda, 650 7580-000 - Pompéia - SP - Brasil Tel.: +55 4 3405-00 - Fax: +55 4 345 306 E-mail: export@jacto.com.br
More informationSECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
More informationSampling Solutions. Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved.
Sampling Solutions Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved. Oil Samples are used to obtain a clear indication of the operating status of your machinery. One of the most
More informationESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA
December 19, 2013 Sprinkler 122j 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK502 is a fast response fusible element type sprinkler designed for use in storage areas
More information1/29/2008 DR50. Baja Motorsports Inc. P.O. Box 61150 Phoenix, AZ 85082 Toll Free: 888-863-2252 PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 45
DR50 Toll Free: 888-863-2252 PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 45 CYLINDER & CYLINDER HEAD Part UPC Number Description Baja Description 1 DR50-001 842645074424 CYLINDER 1 1 2 DR50-002 842645074431
More information3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide
", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,
More informationCost Evaluation of Black Steel Pipe and Galvanized Pipe When Using a Nitrogen Generator
Cost Evaluation of Black Steel Pipe and Galvanized Pipe When Using a Nitrogen Generator Andy L. Kaempfer Business Development Manager Potter Electric Signal Company, LLC 1609 Park 370 Place St. Louis,
More informationPipe Sizing for Commercial and Industrial Natural Gas at Operating Pressures 75 mbar
Pipe Sizing for ommercial and Industrial Natural Gas at Operating Pressures 75 mbar These notes form part of the gas safety training programme from RD Training (Midland) Ltd. They are for information only
More informationREFER TO SPECIFICATIONS AND STANDARD PLANS FOR DETAILED WATER METER, METER VAULT, AND SERVICE LINE REQUIREMENTS
GENERAL REQUIREMENTS METER, METER VAULT, AND SERVICE LINE REFER TO SPECIFICATIONS AND STANDARD PLANS FOR DETAILED METER, METER VAULT, AND SERVICE LINE REQUIREMENTS METER & METER VAULT: 1. METER AND RADIOREAD
More informationNumber Wheeler P/N Description Set Rex P/N Notes
1 607051 Base 1 A050 2 607052 Motor Cover 1 A052 3 600778 Socket Hd Cap Screw (M8x60) 2 4 607053 Scrap Receiver 1 A053 5 607054 Tank Upper Cover 1 A054 6 607055 Oil Pot 1 A055 7 607056 Strainer 1 A056
More informationFACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING 21 11 00
211100_flexheadin_01_MS_0409 5/22/09 PTC 56 Lowland Street Holliston, MA 01746 Phone: (800) 829-6975 Phone: (508) 893-9596 Fax: (508) 893-6020 E-mail: sales1@flexhead.com www.flexhead.com This MANU-SPEC
More informationGEET Fuel Processor Plans
GEET Fuel Processor Plans This is a greatly simplified Proof of Concept version of the GEET Fuel Processor that just about anyone can build from parts from a local Hardware store in a weekend for very
More informationCopper Meter Resetters
Copper Meter Resetters To Set 5/8", 5/8" x 3/4", 3/4", 1", 1 1 2" & 2" Water Meters 11/12 Table of Contents Page Page Meter Resetters 5/8", 5/8" x 3/4", 3/4", & 1" Horizontal Inlet and Outlet Series 710
More informationInstallation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab
GOOSENECK MOUNTING KIT Equipment Required: Fastener Kit: F Wrenches: 3/4, 7/8, 15/16 Drill Bits: 1/4 Other Tools: Drill WARNING: Under no circumstances do we recommend exceeding the towing vehicle manufacturers
More informationPartitioning & Ceiling Product Information
Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44
More informationMOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
More informationDR90. Baja Motorsports Inc. P.O. Box 61150 Phoenix, AZ 85082 Toll Free: 888-863-2252 PART NUMBERS AND PRICES ARE SUBJECT TO CHANGE 1 of 51
DR90 Toll Free: 888-863-2252 PART NUMBERS AND PRICES ARE SUBJECT TO CHANGE 1 of 51 CYLINDER & CYLINDER HEAD Part UPC Number Description Baja Description 1 DR90-001 842645048166 CYLINDER 1 1 2 DR90-002
More informationNumber Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8)
1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 4 5 600130 Spring Washer (8mm) 4 6 600344 Roll Pin (M6x30) 4 7 600129 Socket Hd Cap Screw (M8x25) 4 8
More informationPARTS LIST T30 MODEL 2545 TWO STAGE INDUSTRIAL AIR COMPRESSOR
Ingersoll-Rand Company 800-B Beaty Street P. O. Box 1803 Davidson, NC 28036 1-800-AIR-SERV (1-800-247-7378) www.air.ingersoll-rand.com PARTS LIST T30 MODEL 2545 TWO STAGE INDUSTRIAL AIR COMPRESSOR Ingersoll-Rand
More informationDouble-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.
Picture Item No. Description RO- 0010 Brass Water Feed 1. 3/4" FIP with 1/4" hole 2. Using on R.O. tank RO- O020 Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP RO- 0030 Brass
More informationAPI Flanged Safety Relief Valves Series 526 CATALOG
API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes
More informationReplacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
More informationDV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.
Worldwide Contacts www.tyco-fire.com DV-5 Deluge Valve with Trim 4 Inch and 6 Inch (DN and DN5) General Description The TYCO DV-5 Deluge Valve with Trim is a diaphragm-style valve that depends upon water
More informationCNC Tool Storage Solutions
Solutions CNC TOOL STORAGE SOLUTIONS Thanks to the flexibility of the CNC line, your tools will be protected during regular handling, transportation and storage. The Rousseau CNC tool rack distinguishes
More informationUni-Quick Duct System. Moveable. Uni-Quick. Duct System. DUST COLLECTION and MATERIAL HANDLING APPLICATIONS a McGill AirFlow product
United McGill products Uni-Quick TM An enterprise of United McGill Corporation Family owned and operated since 1951 Moveable Duct System DUST COLLECTION and MATERIAL HANDLING APPLICATIONS a McGill AirFlow
More information*** MAIN VERSION OF BOM ***
*** MAIN VERSION OF BOM *** This is the main parts list for the 2013-2014 FTC game. The parts are listed in different categories (such as "Field Elements, "Hardware," "Wood," etc.). The item numbers assigned
More informationSERVICE PARTS LIST AND ASSEMBLY INSTRUCTIONS
T-352PL Manual SERVICE PARTS LIST AND ASSEMBLY INSTRUCTIONS for FlexCLIK Hose & Fittings T-352PL REV. 11/2012 2012 Mobile Climate Control TABLE OF CONTENTS 1 INTRODUCTION... ii 2 ORDERING INSTRUCTIONS...
More informationWet alarm valves. Wet alarm valves. FM trim
Description Usually, a wet alarm valve station comprise: - a Rolland wet alarm valve linked to the water motor gong. - a set of valves and by pass used to test the system. - a drain valve. - a test valve
More informationService Parts. John Deere TO4039D 4039TL CD4039DF CD4039TF 4045DF 4045TF. Engine. Engine Models:
Service s Engine Engine Models: John Deere TO4039D 4039TL CD4039DF CD4039TF 4045DF 4045TF Generator Models: 20--40ROZJ/REOZJ 20--40DSJ/DSEJ 50/60ROZJ serial nos. 257821 and above 50/60REOZJ/REOZJB 50/60DSJ/DSEJ/DSEJB
More informationFOR THE MOST CURRENT PRODUCT / PRICING INFORMATION ON ANVIL PRODUCTS, PLEASE VISIT OUR WEBSITE AT WWW.ANVILINTL.COM
CTS COPPER SYSTEM Price Sheet GR.CTS-5.14 Effective Date: May 12, 2014 Cancels Price Sheet GR.CTS-5.13 of May 28, 2013 FOR THE MOST CURRENT PRODUCT / PRICING INFORMATION ON ANVIL PRODUCTS, PLEASE VISIT
More informationInstallation E19-310. Combination Drench Shower/Eyewash. Table of Contents
Installation E19-310 Combination Drench Shower/Eyewash Table of Contents Pre-Installation Information...................... Installation Instructions.........................3 Assembly of Components.......................
More informationComplete Systems & Parts Automatic Oiler & Grease Bank
MADE IN THE USA Complete Systems & Parts Automatic Oiler & Grease Bank www.gosuburban.com 2 Lubrication Systems Lubrication Systems, a division of Suburban Manufacturing, manufactures a complete line of
More informationC. CR: Chlorosulfonated polyethylene synthetic rubber. E. EPDM: Ethylene-propylene-diene terpolymer rubber.
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
More informationPSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS
PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS AC AND DC GENERATOR SCHEMATIC ENGINE GENERATOR ASSEMBLY REF Description QTY PSS10 PSS12 1 Engine, Honda GX620K1VXC2 Code 637220 1 99779-000 GX670VXC2 Code 637220
More informationCUTTER-CRUSHER RAMMER RC 22
11/99 PARTS MANUAL PMRC22EN.A99 CUTTER-CRUSHER RAMMER RC 22 SERIAL NO. RC22BC0015-UP RC22RC0021-UP TABLE OF CONTENTS 1. Cylinder RC 22.......................................................... 4 2. Hydraulics
More informationInstallation Instructions
GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover
More informationIndirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
More information2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
More informationTAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * 41.729.220 Thermostat for CH 12/18
ACCESSORIES RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. Digital timer, burning and ventilating. Fault detector GSM. GSM temperature fault detector. THERMOSTATS RT1, room thermostat -10/+40 C with 5
More information5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such
More informationASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.
ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.4-1998 - Cast Iron Threaded Fittings ASME/ANSI B16.5-1996 - Pipe
More informationTECHNICAL DATA. 30a. September 18, 2009 1-1/4-8 (DN32 - DN200)
September 18, 2009 30a 1. DESCRIPTION Viking EasyPac Commercial Riser Manifold Assemblies are available in sizes 1-1/4, 1-1/2, 2, 2-1/2, 3, 4, 6 and 8 for commercial systems. They are available with an
More informationStandard Bills of Materials Commonly Ordered Models Only
Standard Bills of Materials Commonly Ordered Models Only Meters Always check www.lcmeter.com for the most current BOM. This document is for reference only. Always use Bill of Material shipped with meter
More informationSheet Metal Products for the HVAC Industry
2 0 1 2 P R O D U C T C A T A L O G Sheet Metal Products for the HVAC Industry Quality Products Since 1989 A B O U T R O Y A L M E T A L P R O D U C T S About Royal Metal Products Royal Metal Products
More informationGAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES
GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today
More informationChief EZ Liner S21 PARTS MANUAL. 1999 Chief Automotive Systems, Inc.
Chief EZ Liner S21 R 1999 Chief Automotive Systems, Inc. CHIEF EZ LINER CHIEF S LIMITED ONE-YEAR WARRANTY & LIABILITY Chief Automotive Systems, Inc. warrants for one year from date of installation and/or
More informationInstalling a Probe. Typical Installation
for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods by the Control Drawing referenced on the product s name tag 2. The Feed Through Assembly
More informationLIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH. 10 40 BLACK & GALVANIZED STEEL PIPE
FASTLOCK fittings are not currently approved for use with gas or fire protection applications. FITTINGS FOR STEEL PIPE LIST PRICE BOOK MALLEABLE CAST IRON FITTINGS FOR SCH. 10 40 BLACK & GALVANIZED STEEL
More informationVectaire Gas Convection Ovens (Vertical Door)
MONTAGUE Vectaire Gas Convection Ovens (Vertical Door) 70, 115 2-70 & 2-115 Vectaire Gas Convection Ovens (Vertical Door) 456 115A Series Vertical Door Model 1 3395-2 Thermostat, Gas (FDO) 2 1024-3 Dial,
More informationRecommended Fuel Piping Specification For UPP Piping, UL-971
Recommended Fuel Piping Specification For UPP Piping, UL-971 1.0 General The primary delivery piping system shall be for suction or pressure applications and have semi-rigid coaxial type double wall construction,
More informationInstallation Manual DIAPHRAGM WELL TANK
Installation Manual DIAPHRAGM WELL TANK Safety Instructions Installation Warranty IN-LINE SERIES: 2-5 & 7 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON VERTICAL SERIES: 14-20-32-36-52-86-96-119 GALLON KEEP
More informationSTAINLESS STEEL FITTINGS & COUPLINGS Price Sheet GR.SS-5.14 Effective: May 12, 2014 Cancels Price Sheet GR.SS-5.13 of May 28, 2013
FITTINGS & COUPLINGS Price Sheet GR.SS-5.14 Effective: May 12, 2014 Cancels Price Sheet GR.SS-5.13 of May 28, 2013 FOR THE MOST CURRENT PRODUCT / PRICING INFORMATION ON ANVIL PRODUCTS, PLEASE VISIT OUR
More informationVOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
More informationPIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant
More informationIMPORT CAST IRON THREADED FITTINGS Price Sheet SPF.CI-3.14C Effective March 10, 2014 Cancels Price Sheet SPF.CI-7.12C of July 2, 2012
IMPORT CAST IRON THREADED FITTINGS Price Sheet SPF.CI-3.14C Effective March 10, 2014 Cancels Price Sheet SPF.CI-7.12C of July 2, 2012 FOR THE MOST CURRENT PRODUCT / PRICING INFORMATION ON ANVIL PRODUCTS,
More informationSECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
More informationINDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED
INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED Available in Sizes B C D E See Page 6 for Dimensions Kennedy Valve/Indicator Posts 17-1 INDICATOR POST STYLE 2945 A TELESCOPING
More informationABS DWV FITTINGS ABS-0215 FEBRUARY 2015 SUPERCEDES ABS-1214 ASTM D2661
ABS DWV FITTINGS ABS-0215 FEBRUARY 2015 SUPERCEDES ABS-1214 ASTM D2661 COUPLING 1 1/4" 601112 125 9,000 2.60 1 1/2" 601120 125 9,000 1.74 2" 601138 100 4,800 2.34 3" 601146 45 1,440 6.57 4" 601153 25 800
More informationInstallation Instructions
Installation Instructions Built-In Dishwasher If you have questions, call 1-800-4-MY-HOME (1-800-469-4663) or visit our website at: www.sears.com BEFORE YOU BEGIN Read these instructions completely and
More information8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P-24258 B-24258 E-24259 B-24259 B-24266 B-24267
BALL ANGLE METER VALVES - 3/4" & " 8D. B-24258 MUELLER 300 Ball Angle Meter Valve MUELLER 0 Conductive Compression Connection for CTS O.D.* tubing x meter swivel nut** adding -3 suffix to catalog number.
More informationCALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04
BROWN MINNEAPOLIS TANK PAGE 1 OF 7 PURPOSE: Create and Drawing Uniformity Create, explain, and establish a standard bill of materials to be placed on every drawing (except the overall tank elevation and
More informationInstructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.
Instructions Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG Model 24G766 Important Safety Instructions For complete warnings and safety instructions see RoadLazer RoadPak
More informationBuilder Specifications for Solar Ready Homes
Builder Specifications for Solar Ready Homes This document specifies the essential elements required to make a new home ready for the future installation of roof-mounted solar domestic hot water and photovoltaic
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More information倀 䰀 唀 䴀 䈀 䤀 一 䜀 刀 䄀 䤀 一 圀 䄀 吀 䔀 刀 匀 夀 匀 吀 䔀 䴀 匀
倀 䰀 唀 䴀 䈀 䤀 一 䜀 刀 䄀 䤀 一 圀 䄀 吀 䔀 刀 匀 夀 匀 吀 䔀 䴀 匀 眀 眀 眀 最 攀 渀 漀 瘀 愀 瀀 爀 漀 搀 甀 挀 琀 猀 挀 漀 洀 㠀 ⴀ 㔀 ⴀ 㜀 㐀 㠀 㠀 September 2015 R.F. Williams, Michigan Master Plumber, License No. 04287 (left) R.M. Williams, Michigan
More informationTD01211 PIN: NX010 201007.2 nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA
Water Motor Alarm MODEL: NX010 GENERAL DESCRIPTION TECHNICAL SPECIFICATIONS Model NX010 Working Water Pressure Range 5 to 175 psig 0.035 to 1.2 MPa (0.35 to 12 bar) Shipping Weight 11 lbs 5 kg Alarm Line
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS
San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS 854.1 DESCRIPTION: This item shall govern sanitary sewer laterals installed in accordance with these
More informationSUBMITTAL 10 FEET. Cast Iron Soil Pipe Products Hubless Pipe & Fittings HUBLESS PIPE 10 FEET*
QUALITY SYSTEM SUBMITTAL Hubless Pipe & Fittings R E G I S T R AT I O N Manufacturer s T J B 10 FEET HUBLESS PIPE 10 FEET* NOM. SIZE B INSIDE DIAMETER J OUTSIDE DIAMETER 1 1/2 1.50 1.90 0.16 0.13 28.4
More informationINSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS
INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS SETTING UP THE PRESS FOR OPERATION For shipping convenience, the gauge, pump handle, hoist crank, screw nose and base angles
More informationSTANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS
STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for cleaning and lining existing cast iron and ductile iron water mains
More informationHeating Cable. Construction
Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant
More informationFittings, Tubing & Nipples
s, Tubing & Nipples P Series Pipe s s to 15,000 psi (1034 bar) Since 1945 Parker utoclave Engineers has designed and built premium quality valves, fittings and tubing. This commitment to engineering and
More informationSIZING AND CAPACITIES OF GAS PIPING
APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following
More informationScraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
More informationTemperature Adaptor. Vacuum Tree
Temperature Adaptor Temperature Adaptor Temperature Adaptor B0N Ford XY on 6 cyl B02N Ford XF on 6 cyl B0N Ford XE-XF 6 cyl B0N Ford 20 Eng. Tree of 2 BN Ford 20 Eng. Tree of BP Ford 20 Eng. Tree of Water
More informationSingle Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller
Specifications Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller Introduction These purchase specifications cover the minimum requirements of a Single Deadman Air Lifting Bag (ALB) Controller
More informationSurface Water Drainage Products
Surface Water Drainage Products Surface Water Drainage Products Reln Rain Drain 1m Lengths (Internal dimensions 100mm x 100mm) 118mm 100mm 100mm 128mm 1m 001134 001133 001200 001188 001195 001190 001143
More informationProduct catalogue, pipe and sewer cleaning systems
Product catalogue, pipe and sewer cleaning systems Nozzles Rotorjet trolley Hose reels Cleaning devices www.hammelmann.com Contents (Navigation via Bookmarks) Rotorjet trolley Rotary joints, spray pipes
More informationMeritor Tire Inflation System (MTIS) by PSI
Meritor Tire Inflation System (MTIS) by PSI PB-9999 Revised 5/07 including Meritor ThermALERT Table of Contents Repair Kits and Components Page Control Box 4 Hoses 6 Hub Caps 7 Light 4 Press Plug Kits
More informationTutorial 8: Setting Up a Barcode Scanner
Tutorial 8: Setting Up a Barcode Scanner This tutorial explains how to use a barcode scanner with PranaStudio. PranaStudio allows you to use a scanner on your products and to assign a barcode to a student.
More information