BD Beaver and BD Visitec Product Catalog
|
|
- Clinton Burke
- 7 years ago
- Views:
Transcription
1 BD Beaver and BD Visitec Product Catalog BD Medical - Ophthalmic Systems
2 Table of Contents Ophthalmic Surgery Procedure Kits Custom BD CustomEyes Cataract Disposable Instrument Kit Microsurgical Accessory Kit Ophthalmic Surgery Kit Refractive Refractive Kits LASIK LASIK Kit Limbal Relaxing Incision (LRI) Accurate Depth Knife micron Accurate Depth Knife micron OcuSeal BD OcuSeal Cataract Surgery Absorbing Products Sponges Swabs Instrument Wipes Cannulas Anesthesia Administration Peribulbar Anesthesia Retrobulbar Anesthesia Retrobulbar/Peribulbar Anesthesia Sub-Tenon s Anesthesia Capsule Polishing Capsule Polishers Cortex Removal Cortex Extractors J Shape Cannulas Hydrodissection and Hydrodelineation Cortical Cleaving Hydrodissection Cannulas Hydrodissection Cannulas Hydrodelineation Cannulas J Shape Hydrodissection Cannulas Irrigation and Air Injection Anterior Chamber Cannulas Irrigating Cannulas Viscoelastic Cannulas Table of Contents I
3 Table of Contents Table of Contents I and A Cannulas (Irrigation and Aspiration) Bimanual I and A Cannulas Coaxial I and A Cannulas I and A Cannula Simcoe I and A Cannulas Simcoe I and A Cannulas (Reverse) Nucleus Removal Irrigating Vectis Expression Cannulas Cystotomes Capsulotomy Capsulorhexis Cystotomes Formed, Angled, and Straight Cystotomes Intercapsular/Endocapsular Cystotomes Sharp Cystotomes Fluid Administration Extension Set Fluid Administration Sets Fluid Filter Disposable Instruments Forceps Needle Holder Manipulators Scissors Speculums Instrument Kit ,22 Manipulators/Iris Retractors IOL Manipulation Flexible Tip Intraocular Lens Manipulators Intraocular Lens Manipulators ,24 Nucleus Manipulation Nucleus Chopper Nucleus Rotator Nucleus Spatula Iris Retraction Iris Retractors Irrigating Iris Retractors Drapes and Fluid Collectors Drapes and Fluid Collection Fluid Collection Full Body Drapes Minor Surgery Drapes Outpatient Surgery Drapes Eye Protection Products Eye Protection Products Corneal Light Shields Eye Patches Eye Shields II
4 Table of Contents Knives, Blades, Handles and Fixation Ring Knives and Blades Accurate Depth Knives Cataract and Keratome Blades Circular Knives Crescent Knives and Blades Implant Knives and Blades Intraocular Lens Knives Lamellar Blades Micro-Blades BD Micro-Unitome Knives and BD Micro-Sharp Blades Mini-Blades and Knife MVR Knives Needle Blades Safety Knives Scleral Knives and Blades Sclerotome Blade and Knife Slit Knives and Blades ,37 Stab Incision Knives and Blades Handles Handles Fixation Ring Fixation Ring Viscoelastic/Viscoadaptive Viscoelastic BD 1% BD 1.0% OVD BD 1.2% OVD BD Visc BD HPMC Viscoadaptive BD Multivisc Saline Solution Saline Solution Saline Solution Miscellaneous Adapters Anterior Chamber Maintainers Instrument Handle Instrument Wipes Marking Pad Speculums Sponges and Swabs Surgical Glides Syringe Table of Contents III
5 Table of Contents Refractive Surgery Accessories Eye Drains, Shields and Sponges Marking Pad Refractive Drapes Re-Positioners Spatulas Spears Cannulas Cannulas LASEK LASEK Instruments Glaucoma Surgery Table of Contents Instruments Glaucoma Cannula Glaucoma Revision Picks Glaucoma Trabeculectomy Knives and Blades Non-Penetrating Sclerectomy Knives Oculoplastic Surgery Specialty Products Frontalis Suspension Set Lacrimal Cannulas Lacrimal Dilator and Probe Lacrimal Intubation and DCR Lacrimal Trephine Vitreoretinal Surgery Cannulas Delaminator & Viscodissectors Flute High Viscosity Injector Infusion Membrane Dissectors Micro-tip Silicone Oil Removal Subretinal Fluid Transcleral Drainage Vitreoretinal IV
6 Table of Contents Vitreoretinal Surgery (continued) Accessories Micro Iris Hooks Cotton Swabs Vitreoretinal Brush Knives MVR Knives Safety Sideport Knife Product Index by Product Number Product Index by Product Type Label Information How to Order Hubs Inside Back Cover Table of Contents V
7 Ophthalmic Surgery Procedure Kits Ophthalmic Surgery - Procedure Kits BD CustomEyes Surgery Kits Design your own custom kit for any type of ophthalmic surgery including: Cataract, Refractive, Vitreoretinal, Oculoplastic and Glaucoma. Catered to meet the needs of Private Ophthalmic Clinics Public Hospitals Day Surgery Units Wait-listed Departments Government Tenders Refractive Centers Benefits Designed to save valuable time preparing for surgery and help minimize possible errors in the set-up of an operation Designed to require less ordering time than purchasing items separately All-in-one packaging may reduce inventory and environmental waste Cataract Surgical Kits Popular products combined into one package for convenience and cost savings BD Disposable Instrument Kit Includes: Bonn Forceps (with plastic handle) Capsulorhexis Forceps (with plastic handle) Micro-Manipulator (with plastic handle) Sinskey hook (with plastic handle) Eye Speculum (open blade) BD Microsurgical Accessory Kit Includes: Fluid Collection Bag BD Visiwipe Instrument Wipe BD Visidrain Eye Fluid Wick Corneal Light Shield BD Ophthalmic Surgery Kit Includes: BD Visiwipe Instrument Wipe BD Visidrain Eye Fluid Wick Corneal Light Shield 10 kits per box 20 kits per box 20 kits per box 6
8 Ophthalmic Surgery Procedure Kits Refractive Kits BD Refractive Kit + Includes: 90 cm x 90 cm (30 x 30 ) CSR Wrap LASIK Eye Spears BSS, 18 ml 3 ml Luer-Lok Syringe Mini Incise Drape 1 kit per box BD Refractive Kit + Includes: 90 x 90 cm (30 x 30 in) CSR Wrap BSS, 18 ml LASIK Eye Spear 3 ml Luer-Lok Syringe Dual Refractive Drape LASIK Kit BD LASIK Kit + Includes: 90 cm x 90 cm (30 x 30 ) CSR Wrap Trolley Cover Label LASIK Eye Spears BSS 18 ml 4 x 4 Ply Gauze Pad 3 ml Luer-Lok Syringe Dual Refractive Drape Instrument Wipe Gentian Violet Marker Pad LASIK Eye Drain (Chayet) Limbal Relaxing Incision (LRI) Kits 1 kit per box 1 kit per box This kit is designed to give you the tools you need for creating Limbal Relaxing Incisions. These kits match a high quality BD Beaver Accurate Depth Knife with the flexibility of the BD Beaver Swivel Fixation Ring. These products are single-use and come to you in a single package BD Beaver Accurate Depth Knife micron Precise depth incision with pre-set guard, bi-directional blade cuts left or right, multiple depth options available. Includes: Accurate Depth Knife Swivel Fixation Ring 1 - Marking Pen Ophthalmic Surgery - Procedure Kits BD Beaver Accurate Depth Knife micron Precise depth incision with pre-set guard, bi-directional blade cuts left or right, multiple depth options available. Includes: Accurate Depth Knife Swivel Fixation Ring 1 - Marking Pen 2 kits per box + Available in the U.S. only 7
9 Ophthalmic Surgery OcuSeal OCUSEAL LIQUID OCULAR BANDAGE A liquid ocular bandage designed to provide a barrier whilst stabilising ocular wounds. Can be used post surgically, or following non-surgical trauma and other ocular conditions. OcuSeal is a fully synthetic product developed to promote healing and comfort for the patient, by protecting the cornea from mechanical trauma caused by eyelid movement OcuSeal is intended for use in: Refractive and Cataract surgery As an adjuct to sutures in pterygium surgery Corneal abrasions free from foreign matter Scleral incisions Ophthalmic Surgery - OcuSeal * BD OcuSeal TM Liquid Ocular Bandage * Not Available in the U.S. 8
10 Cataract Surgery Anesthesia Administration BD Visitec Peribulbar Anesthesia Indicated for injecting anesthetic agents around the globe (periocular) Peribulbar [Atkinson].40 x 22 mm (27G x 7/8 in) Peribulbar [Atkinson].50 x 22 mm (25G x 7/8 in) Peribulbar [Atkinson].60 x 22 mm (23G x 7/8 in) BD Visitec Retrobulbar Anesthesia Indicated for injecting anesthetic agents into the muscle cone Retrobulbar [Atkinson].50 x 38 mm (25G x 1 1/2 in) Retrobulbar [Atkinson].60 x 38 mm (23G x 1 1/2 in) Designed to course around the globe and enter the anterior region of the muscle cone inferotemporal and parallel to the optic nerve. US Patent 4,759, Retrobulbar (Curved) [Atkinson/Straus].50 x 34 mm (25G x 1 3/8 in)* * Dimensions after bending Retrobulbar (Sharp Point).50 x 38 mm (25G x 1 1/2 in) BD Visitec Retrobulbar/Peribulbar Anesthesia Retrobulbar/Peribulbar [Atkinson].40 x 32 mm (27G x 1 1/4 in) Retrobulbar/Peribulbar [Atkinson].50 x 32 mm (25G x 1 1/4 in) Retrobulbar/Peribulbar [Atkinson].60 x 32 mm (23G x 1 1/4 in) Straight portion 9.5 mm, curved portion 24.5 mm Cataract Surgery - Anesthesia Administration BD Visitec Sub-Tenon s Anesthesia Designed for administering anesthetic agents into the posterior sub-tenon s space Sub-Tenon s Anesthesia Cannula 1.10 x 25 mm (19G x 1 in) Curved to a radius of 30 mm and flattened to.65 mm 9
11 Cataract Surgery Capsule Polishing BD Visitec Capsule Polishers Flexible Tip Cannula.40 x 22 mm (27G x 7/8 in) 45, 7 mm from end 10 mm sleeve Flexible Tip Cannula.60 x 22 mm (23G x 7/8 in) 45, 7 mm from end 10 mm sleeve Cataract Surgery - Capsule Polishing Capsule Polisher [Kratz].60 x 22 mm (23G x 7/8 in);.30 mm top port 35, 9 mm from end; micro etched 3 mm from end Capsule Polisher [Kratz].80 x 22 mm (21G x 7/8 in);.30 mm top port 35, 9 mm from end; micro etched 3 mm from end Capsule Polisher.80 x 22 mm (21G x 7/8 in);.50 mm open end port 30, 3 mm from end; micro etched 5 mm from end Posterior Scraper [Simcoe].60 x 22 mm (23G x 7/8 in);.33 mm open end port 60, 7 mm from end; micro etched end Olive Tip Polisher [Pearce].50 x 24 mm (25G x 15/16 in);.30 mm top port 30, 10 mm from end; micro etched 3 mm from end Olive shape tip is 3 mm long x 1.5 mm wide Olive Tip Polisher.60 x 25 mm (23G x 1 in);.33 mm end port 30, 10 mm from end; micro etched 2 mm from end Olive shape tip is 2 mm long x 1 mm wide J Shape Cannula [Thorton].55 x 22 mm (24G x 7/8 in);.30 mm open end port Hook 2.75 mm long x 2.5 mm wide Slightly micro etched on back of J shape end for capsule polishing. May also be used for aspiration of cortex from the superior iris between the 10-2 o clock meridian. 10
12 Cataract Surgery Cortex Removal BD Visitec Cortex Extractors Cortex Extractor [Blumenthal].60 x 23.5 mm (23G x 15/16 in);.40 mm top port, thinwall cannula, 30, 2 mm from end; micro etched 2 mm from end. May also be useful for capsule polishing Cortex Extractor.60 x 16 mm (23G x 5/8 in);.40 mm top port Thinwall cannula Cortex Extractor.60 x 16 mm (23G x 5/8 in);.30 mm top port Cortex Extractor.80 x 16 mm (21G x 5/8 in);.30 mm top port Cortex Extractor [Charleux].55 x 12.5 mm (24G x 1/2 in);.30 mm end port angled 10 Flat end opening has rounded edges. BD Visitec Cortical Cleaving Hydrodissection* Cannulas Cortical Cleaving Hydrodissector (Grabow).30 x 16 mm (30G x 5/8 in) 40, 12 mm from end.30 mm cannula helps create a cleavage plane between the capsule and cortex Cortical Cleaving Hydrodissector (Flat End).40 x 22 mm (27G x 7/8 in) 45, 11 mm from end For cleaving cortex from capsular bag Cortical Cleaving Hydrodissector (Round End).40 x 22 mm (27G x 7/8 in) 45, 11 mm from end For cleaving cortex from capsular bag. May also be used for general irrigation. Cataract Surgery - Cortex Removal Cortical Cleaving Hydrodissector [Bolger].50 x 22 mm (25G x 7/8 in) Tip is tapered to.30 mm (30G); 33, 1 mm from end. Facilitates placement under anterior capsule for cleaving cortex from capsular bag. *Fine, I.H., Cortical Cleaving Hydrodissection 11
13 Cataract Surgery Hydrodelineation and Hydrodissection Cataract Surgery - Hydrodelineation and Hydrodissection BD Visitec J Shape Cannulas Micro J Shape Cannula.50 x 22 mm (25G x 7/8 in);.25 mm open end port Hook 1.5 mm long x 1.75 mm wide Designed for small incision surgery J Shape Cannula.60 x 22 mm (23G x 7/8 in);.33 mm open end port Hook 2 mm long x 2.25 mm wide Micro J Shape Cannula [Hessburg].50 x 20 mm (25G x 3/4 in);.25 mm open end port Hook.85 mm long x 1.7 mm wide J Shape Cannula [Thornton].55 x 22 mm (24G x 7/8 in);.30 mm open end port Hook 2.75 mm long x 2.5 mm wide Slightly micro etched on back of J shape end for capsule polishing. BD Visitec J Shape Hydrodissection Cannulas For hydrodissection between the 10-2 o clock meridian Micro J Shape Hydrodissector [Pearce].40 x 22 mm (27G x 7/8 in) Hook 2.25 mm long x 1.75 mm wide Micro size flattened tip for easy insertion through wound and under capsule J Shape Hydrodissector [Pearce].50 x 22 mm (25G x 7/8 in) Hook 3 mm long x 2 mm wide Compound curve allows placement of cannula under nucleus for expression. Angled tip is useful to hook and remove nucleus HydroExpression Cannula [Corydon].40 x 22 mm (27G x 7/8 in); 30, 1.8 mm from end. Designed to express the nucleus with balanced salt solution through a capsulorhexis during ECCE ViscoExpression Cannula [Corydon].50 x 22 mm (25G x 7/8 in); 30, 1.8 mm from end. Designed to express the nucleus with viscoelastic through a capsulorhexis during ECCE. 12
14 Cataract Surgery Hydrodelineation and Hydrodissection BD Visitec Hydrodissection Cannulas Nucleus Hydrodissector.30 x 22 mm (30G x 7/8 in) 45, 7 mm from end. Also useful for irrigating incisions during refractive procedures Nucleus Hydrodissector [Sauter].40 x 22 mm (27G x 7/8 in) Tip is flattened on the vertical plane Nucleus Hydrodissector.40 x 22 mm (27G x 7/8 in) Tip is flattened on the horizontal plane Nucleus Hydrodissector [Sinskey].50 x 22 mm (25G x 7/8 in) 35, 8 mm from end. Unique forked tip rotates nucleus following hydrodissection to facilitate cleaving of nuclear cortical connections Nucleus Hydrodissector [Pearce].50 x 22 mm (25G x 7/8 in) 35, 8 mm from end Nucleus Hydrodissector.40 x 22 mm (27G x 7/8 in) 35, 8 mm from end Tangential Hydrodissector [Hart].50 x 22 mm (25G x 3/4 in), 35, 8 mm from end. Modified J shape cannula with a flattened tip (.4 mm). BD Visitec Hydrodelineation Cannulas Nucleus Hydrodelineator [P. Koch].50 x 22 mm (25G x 7/8 in) Shortened, single bevel tip easily penetrates the nucleus for manual sculpting to improve lamellar separation prior to phacoemulsification. Flattened end provides smooth insertion under anterior capsule for hydrodissection Tapered Hydrodelineator [Blumenthal].50 x 22 mm (25G x 7/8 in) Tip is tapered to.30 mm (30G); 45, 4 mm from end. Tapered to allow greater flow of fluid through a smaller tip. Provides easy insertion under capsule for hydrodissection or into nucleus for hydrodelineation. Cataract Surgery - Hydrodelineation and Hydrodissection 13
15 Cataract Surgery Irrigation and Air Injection BD Visitec Anterior Chamber Cannulas Dome shape, extra smooth tip designed to provide safe insertion through wound and manipulation within the eye. 45, 4 mm from end Anterior Chamber Cannula [Rycroft].30 x 22 mm (30G x 7/8 in) Cataract Surgery - Irrigation and Air Injection Anterior Chamber Cannula [Rycroft].40 x 22 mm (27G x 7/8 in) Anterior Chamber Cannula [Rycroft].50 x 22 mm (25G x 7/8 in) Anterior Chamber Cannula [Rycroft].60 x 22 mm (23G x 7/8 in) Anterior Chamber Cannula [Rycroft].80 x 22 mm (21G x 7/8 in) Anterior Chamber Cannula.40 x 22 mm (27G x 7/8 in) BD Visitec Irrigating Cannulas Olive Tip Cannula.60 x 22 mm (23G x 7/8 in).33 mm end port Olive shape tip is 2 mm long x 1 mm wide Bishop Harmon Cannula 1.1 x 25 mm (19G x 1 in) 40, 8 mm from end Anterior Chamber Cannula 1.6 x 25 mm (16G x 1 in) 30, 6 mm from end BD Visitec Viscoelastic Cannulas Longer design from bend to tip allows for easier placement of viscoelastic to all meridians. May be used to coat intraocular lenses prior to insertion. Dome shape, extra smooth tip designed to provide safe insertion through wound and manipulation within the eye BD Viscoflow Cannula.40 x 22 mm (27G x 7/8 in) Formed 11 mm from end; radius is 19 mm BD Viscoflow Cannula.40 x 22 mm (27G x 7/8 in) 45, 9 mm from end BD Viscoflow Cannula.60 x 22 mm (23G x 7/8 in) 45, 9 mm from end 14
16 Cataract Surgery Irrigation and Air Injection BD Visitec Bimanual I and A Cannulas Separate irrigation and aspiration cannulas insert through two opposing sideport incisions or sideport and phaco incisions. Developed in cooperation with Alistair D. Adams, BSc, FRCS, Edinburgh, Scotland Bimanual Irrigation Cannula.80 x 17 mm (21G x 5/8 in) thinwall cannula Curved 45,.51 mm open end irrigation port Bimanual Aspiration Cannula.60 x 17 mm (23G x 5/8 in) curved 45,.40 mm top aspiration port; micro etched 2 mm from end. Also useful for capsule polishing. BD Visitec Coaxial I and A Cannulas Coaxial I and A Cannula [Pearce] 1.2 mm (18G) thinwall outer cannula provides irrigation,.80 mm (21G) inner cannula has.30 mm side aspiration port. Smooth outer cannula has been designed to create less friction for easier insertion, minimizing trauma to wound Coaxial I and A Cannula (Modified) [Pearce] 1.2 mm (18G) thinwall outer cannula provides irrigation,.80 mm (21G) inner cannula is 30 with a.30 mm side aspiration port. BD Visitec I and A Cannulas I and A Cannula.80 mm/.80 mm (21G/21G).50 mm open end aspiration port I and A Cannula [Gills].60 mm/.50 mm (23G/25G) thinwall 35, 8 mm from end,.25 mm open end aspiration port Cataract Surgery - Irrigation and Air Injection 15
17 Cataract Surgery Irrigation and Aspiration BD Visitec Simcoe I and A Cannulas I and A Cannula [Simcoe].60 mm/.60 mm (23G/23G) thinwall cannula Tubing: ID - 1 mm (.04 in); OD - 2 mm (.08 in).30 mm aspiration port Irrigation Aspiration Cataract Surgery - Irrigation and Air Injection I and A Cannula [Simcoe].60 mm/.60 mm (23G/23G) thinwall cannula Tubing: ID - 1 mm (.04 in); OD - 2 mm (.08 in).30 mm aspiration port I and A Cannula [Simcoe].60 mm/.60 mm (23G/23G) thinwall cannula Tubing: ID - 1 mm (.04 in); OD - 2 mm (.08 in).40 mm aspiration port I and A Cannula [Dahan-Simcoe].60 mm/.60 mm (23G/23G) thinwall cannula Tubing: ID - 1 mm (.04 in); OD - 2 mm (.08 in).40 mm aspiration port Cannulas have micro etched tips to polish the posterior or anterior capsule. BD Visitec Simcoe I and A Cannulas (Reverse) I and A Cannula (Reverse) [Simcoe].60 mm/.60 mm (23G/23G) thinwall cannula Tubing: ID - 1 mm (.04 in); OD - 2 mm (.08 in).30 mm aspiration port Aspiration Irrigation 16
18 Cataract Surgery Nucleus Removal BD Visitec Irrigating Vectis Micro Irrigating Vectis.40 mm (27G), 4 mm wide One.20 mm end port Micro size allows easy access through small pupils Small Incision Irrigating Vectis [Pearce].40 mm (27G), 3 mm wide One.20 mm end port For removing nucleus and fragments through a small incision Irrigating Vectis [Anis].50 mm (25G), 5 mm wide at heart Two.25 mm end ports Heart shape design facilitates retracting iris or capsule for easier insertion under the nucleus Irrigating Vectis [Pearce].50 mm (25G), 5 mm wide One.25 mm end port Irrigating Vectis.50 mm (25G), 5 mm wide Two.25 mm end ports BD Visitec Nucleus Expression Cannulas Compound curve allows placement of cannula under nucleus for expression. Tip is angled for hydrodissection between the 10-2 o clock meridian and useful to hook and remove nucleus HydroExpression Cannula [Corydon].40 x 22 mm (27G x 7/8 in); 30, 1.8 mm from end. Designed to express the nucleus with balanced salt solution through a capsulorhexis during ECCE ViscoExpression Cannula [Corydon].50 x 22 mm (25G x 7/8 in); 30, 1.8 mm from end. Designed to express the nucleus with viscoelastic through a capsulorhexis during ECCE. Cataract Surgery - Nucleus Removal 17
19 Cataract Surgery Nucleus Removal BD Visitec Capsulorhexis Cystotomes Tips are designed to facilitate Continuous Curvilinear Capsulotomies (CCC). Tip has cutting edge from front to back for push or pull cutting. Sharp tip penetrates capsule and allows control of flap. Tip is 90, then rotated Irrigating Cystotome [Blumenthal].40 x 16 mm (27G x 5/8 in) Irrigating Cystotome [Blumenthal].40 x 16 mm (27G x 5/8 in) Formed 8.5 mm from bend to tip Cataract Surgery - Nucleus Removal Irrigating Cystotome [Blumenthal].50 x 16 mm (25G x 5/8 in) Formed 8.5 mm from bend to tip Blunt Tip Irrigating Cystotome [Kellan].50 x 22 mm (25G x 7/8 in) Tip angled toward bevel. Unique blunt tip creates a wide capsular flap. Useful for pear shape capsulotomies BD Visitec Formed, Angled, and Straight Cystotomes Formed cystotomes are bent to conform with the convexity of the crystalline lens. This allows easier access to all areas of the anterior capsule and reduces the chance of touching corneal endothelium Irrigating Cystotome.30 x 16 mm (30G x 5/8 in) Irrigating Cystotome.40 x 16 mm (27G x 5/8 in) Irrigating Cystotome [Pearce].50 x 16 mm (25G x 5/8 in) Side Cutting Irrigating Cystotome.50 x 16 mm (25G x 5/8 in) Irrigating Cystotome.60 x 16 mm (23G x 5/8 in) Shortened curve designed for capsulotomy on deep set eyes or small pupils Irrigating Cystotome.40 x 16 mm (27G x 5/8 in) Formed 8.5 mm from bend to tip Irrigating Cystotome.50 x 16 mm (25G x 5/8 in) Formed 8.5 mm from bend to tip 18
20 Cataract Surgery Cystotomes Irrigating Cystotome.50 x 16 mm (25G x 5/8 in) Tip Irrigating Cystotome (Reverse).50 x 16 mm (25G x 5/8 in) Tip 90 toward bevel Irrigating Cystotome [Simcoe].40 x 12.5 mm (27G x 1/2 in) 45, 10.5 mm from tip Irrigating Cystotome.50 x 16 mm (25G x 5/8 in) Irrigating Cystotome.60 x 16 mm (23G x 5/8 in) BD Visitec Intercapsular/Endocapsular Cystotomes Curve facilitates intercapsular/endocapsular techniques Irrigating Cystotome [Joyce].40 x 16 mm (27G x 5/8 in) Tip.50 mm long Irrigating Cystotome [Joyce].50 x 16 mm (25G x 5/8 in) Tip.50 mm long BD Visitec Sharp Cystotomes Designed for cutting technique capsulotomies. Microsharp blade ground onto the cannula designed to require less pressure to cut the capsule, reducing stress to zonules Sharp Point Cystotome.70 x 27 mm (22G x 1 1/16 in). Tip 1.75 mm long x 1 mm wide Vertical sharp cutting edge Cataract Surgery - Cystotomes Sharp Cystotome.55 x 28 mm (24G x 1 1/8 in) Tip 1.5 mm long x.75 mm wide. Curved sharp cutting edge Sharp Cystotome.55 x 16 mm (24G x 5/8 in). Tip 1.5 mm long x.75 mm wide. Formed 12 mm from bend to tip; radius is 12.5 mm. Curved sharp cutting edge 19
21 Cataract Surgery Fluid Administration BD Visitec Extension Set Superflex Extension Set 25 cm (10 in); ID - 1 mm (.04); OD - 2 mm (.08 in) Soft, flexible tubing with male/female luer connectors 20 per box BD Visitec Fluid Administration Sets Roller valve allows control of fluid flow. Sets with self-priming filter protect against particulates and microbiological contamination of.22 micron and larger. Double sets provide more economical use of irrigating fluid by supporting two simultaneous uses. Cataract Surgery - Fluid Administration Single Fluid Administration Set Tubing length 203 cm (80 in) Double Fluid Administration Set Tubing length 243 cm (96 in) Single Fluid Administration Set with.20 Micron Filter Tubing length 218 cm (86 in) Flow rate is 40 ml/minute at 36 inch bottle height. Flow rate may vary depending on the instruments attached to the tubing. BD Visitec Fluid Filter High Flow Filter.20 Micron Male/female luer lock fittings. Place between syringe and needle or cannula. Filters out particulates and microbiological contamination of.22 micron and larger. 50 per box 20
22 Cataract Surgery Disposable Instruments BD Visitec Disposable Instruments Bonn Forceps Disposable instrument used to grasp tissues. 100 mm long - 12 mm long tip Bonn Forceps (with plastic handle) 105 mm overall product length. Tip section extends 16 mm from plastic handle. Gap between tips at rest - 8 mm Capsulorhexis Forceps Single-use disposable instrument used to cut anterior capsule. 103 mm long - 12 mm long bent tip with iris stop Capsulorhexis Forceps (with plastic handle) 110 mm overall product length. 13 mm bend to tip, 25.8 mm radius - bend to tip section. Gap between tips at rest mm Tying Forceps Single-use disposable instrument used to suture. 100 mm bent tip with micro-trays designed for 10/0 sutures MacPherson Forceps Single-use disposable instrument used to implant intraocular lenses during cataract surgery. 100 mm - 12 mm teeth Moorfield Forceps The Moorfield forceps have a grooved end section to enable the tissue, conjunctiva, etc. to be grasped. length 100 mm, grooved section 13 mm Eye Speculum Used to keep the eyelids open during procedure. 40 mm x 30 mm - 14 mm open ears mm diameter steel Eye Speculum Used to keep the eyelids open during procedure. 40 mm x 30 mm - 14 mm open ears mm diameter steel Needle Holder Single-use disposable instrument used to hold the needle and perform various suture types. 115 mm Vannas Scissors Single-use disposable instrument. Small sharp scissors used to perform small corneal incisions and cut the capsule. 90 mm Westcott Scissors The Wescott Scissors allow cutting/segregation of tissues and cutting of sutures during ophthalmic procedures. length 121 mm, scissor blade - 22 mm Capsulorhexis Forceps (with plastic semi-round handle) 110 mm overall product length. 13 mm bend to tip, 25.8 mm radius - bend to tip section. Gap between tips at rest mm Tying forceps (with plastic semi-round handle) Single-use disposable instrument used to suture. 100 mm bent tip with micro-trays designed for 10/0 sutures. Available soon Cataract Surgery - Disposable Instruments 21
23 Cataract Surgery Disposable Instruments and Speculums Cataract Surgery - Disposable Instruments and Speculums Buratto s Hook Single-use disposable instrument, nucleus manipulator. Used as a second instrument to manipulate the nucleus in the capsular bag in two handed phaco techniques. Blunt, round tip allows easier separation of the nucleus. Angled 0.2 mm diameter, blunt tip Micro-Manipulator (with plastic handle) 130 mm overall product length. 11 mm tip to bend Straight end micro-manipulator Used to manipulate the nucleus Handle length : 95mm - 16mm from handle to 45 bend. 12mm bend to tip distance Sinskey Hook (with plastic handle) 130 mm overall product length. 10 mm tip to bend Hook: 0.85 mm tip to bend distance BD Disposable Instrument Kit Includes: Bonn Forceps (with plastic handle) Capsulorhexis Forceps (with plastic handle) Micro-Manipulator (with plastic handle) Sinskey hook (with plastic handle) Eye Speculum (open blade) BD Visitec Speculums Used to keep the eyelids open during the procedure Pediatric Eye Speculum [Wortham] Overall size: 34 x 21 mm Retraction size: 10 x 3.5 mm Arms are slightly offset to accommodate placement in very small eyes Eye Speculum [Kratz/Barraquer] Overall size: 40 x 26.5 mm Retraction size: 13 x 6 mm Open wire loops decrease the chance of interfering with instruments Eye Speculum Single-use Disposable Speculum Overall size: 40 x 30 mm Retraction size: 14 x.80 mm 0.80mm diameter steel Eye Speculum Single-use Disposable Speculum Overall size: 40 x 30 mm Retraction size: 14 x.90 mm 0.9mm diameter steel 10 kits per box 22
24 Cataract Surgery Manipulators IOL Manipulation For positioning intraocular lenses. Irrigating manipulators can be attached to either a syringe or an irrigating handpiece. BD Visitec Flexible Tip Intraocular Lens Manipulators Flexible sleeve allows IOL manipulation with a soft tip, reducing potential damage to IOL optics. Sleeve extends beyond bend of cannula for atraumatic removal from eye without catching iris or damaging ocular tissue Flexible Tip Cannula.40 x 22 mm (27G x 7/8 in) 45, 7 mm from end 10 mm sleeve Flexible Tip Cannula.60 x 22 mm (23G x 7/8 in) 45, 7 mm from end 10 mm sleeve BD Visitec Intraocular Lens Manipulators Buratto s Hook Single-use disposable instrument, Nucleus manipulator. Used as a second instrument to manipulate the nucleus in the capsular bag in two handed phaco techniques. Blunt, round tip designed to allow easier separation of the nucleus. Angled 0.2 mm diameter, blunt tip IOL Manipulator [Jaffe/Maltzman] Blunt tip, 45, 12 mm from end Fits.20 mm diameter holes and larger IOL Manipulator [Lester] 25 mm diameter tip, 45, 10 mm from end IOL Manipulator [Sinskey] Blunt tip Fits.20 mm diameter holes and larger Cataract Surgery - Manipulators IOL Manipulator [Sinskey] Blunt tip, 45, 15 mm from end Fits.20 mm diameter holes and larger Button Tip Manipulator.50 mm diameter button tip, 45, 15 mm from end. May be used for IOL manipulation or iris retraction IOL Manipulator Blunt tip, formed 10 mm from end Fits.20 mm diameter holes and larger 23
25 Cataract Surgery Manipulators Micro-Manipulator (with plastic handle) 130 mm overall product length. 11 mm tip to bend Straight end micro-manipulator Used to manipulate the nucleus Handle length : 95mm - 16mm from handle to 45 bend. 12mm bend to tip distance Sinskey Hook (with plastic handle) 130 mm overall product length. 10 mm tip to bend Hook: 0.85 mm tip to bend distance. Cataract Surgery - Manipulators Nucleus Manipulation Includes Nucleus Chopper, Nucleus Rotator, and Nucleus Spatula. BD Visitec Nucleus Chopper Nucleus Chopper [P. Koch] 45, 6 mm from tip Tip angled 90, 1.5 mm from end Used as a second instrument to break up the nucleus within the capsular bag during two-handed phaco techniques. Blunt, round tip facilitates easier separation of the nucleus. Specially designed for use with the Stop and Chop technique. BD Visitec Nucleus Rotator Nucleus Rotator [Jaffe/Bechert] Blunt, forked tip, 45 ; 9 mm from end. For rotating nucleus during phacoemulsification. Also useful for dislocating the nucleus into the anterior chamber during extracapsular cataract extraction. Stop and Chop technique using Nucleus Chopper [P. Koch] BD Visitec Nucleus Spatula Smooth, round edges allow for safe manipulation within the eye Spatula [Pearce].80 mm wide 45, 10 mm from end 24
26 Cataract Surgery Iris Retractors Iris Retraction Includes Iris Retractors and Irrigating Iris Retractors. BD Visitec Iris Retractors Micro Iris Hooks [Engels] 8 mm long x.08 mm diameter Flexible, gold wire hooks designed to retract the iris during surgical procedures. 5 packs of Micro Retractor [Pearce] 1 mm wide lip 30, 10 mm from end Micro size allows iris or capsule retraction without interfering with other surgical procedures Button Tip Manipulator.50 mm diameter button tip 45, 15 mm from end May be used for IOL manipulation or iris retraction. BD Visitec Irrigating Iris Retractors Micro J Shape Cannula.50 x 22 mm (25G x 7/8 in);.25 mm open end port. Hook 1.5 mm long x 1.75 mm wide Designed for small incision surgery J Shape Cannula.60 x 22 mm (23G x 7/8 in);.33 mm open end port. Hook 2 mm long x 2.25 mm wide. Cataract Surgery - Iris Retractors Table of Contents 25
27 Cataract Surgery Drapes and Fluid Collectors BD Visitec Fluid Collection For procedures where collection and control of fluid is desired to keep surgeon, patient and floor dry. Reduces operating room cleanup and turnaround time. Bags have an adhesive backing to adhere to surgical drape. Wicks absorb and direct fluid from surgical area into fluid collection bag. Cataract Surgery - Drapes and Fluid Collectors Fluid Collection Bag 17 x 16 cm (6 3/4 x 6 1/4 in) 250 ml capacity Fluid Collection Bag with Wick Bag: 17 x 16 cm (6 3/4 x 6 1/4 in) 250 ml capacity Wick:.40 x 15 cm (5/32 x 5 7/8 in) Mini Fluid Collection Bag with Wick Bag: 9 x 16 cm (3 1/2 x 6 1/4 in) 100 ml capacity Wick:.40 x 15 cm (5/32 x 5 7/8 in) BD Visidrape Minor Surgery Drapes Perfect for refractive or office procedures Mini Plastic Incise Overall size: 41 x 41 cm (16 x 16 in) Incise area: 9 x 11.5 cm (3 1/2 x 4 1/2 in) Mini Plastic Aperture Overall size: 41 x 41 cm (16 x 16 in) Aperture area: 5 x 7.5 cm (2 x 3 in) BD Visiflex Incise Overall size: 11 x 20.5 cm (4 x 8 in) Adhesive area: 11 x 16 cm (4 x 6 1/4 in) Small incise has been designed to provide complete coverage of lashes, lids and brows, reducing the risk of infection. Converts aperture to incise drape per box BD Visidrain Eye Fluid Wick Wick:.40 x 15 cm (5/32 x 5 7/8 in) 20 per box per box 20 per box
28 Cataract Surgery Drapes and Fluid Collectors BD Visidrape Full Body Drapes These full body drapes feature wider widths and a three-sided channel bag for maximum fluid capacity. The full body drape can be utilized in all ophthalmic procedures, including cataract and vitreoretinal procedures Full Body Incise Overall size: 165 x 254 cm (65 x 100 in) Incise area: 9 x 11 cm (3.5 x 4 in) Channel bag: 62 x 40 cm (24 x in) Capacity: 1000 ml Non-Woven Full Body Incise Overall size: 165 x 254 cm (65 x 100 in) Incise area: 9 x 11 cm (3.5 x 4 in) Channel bag: 62 x 40 cm (24 x in) Capacity: 1000 ml Non-Woven Full Body Aperture Overall size: 165 x 254 cm (65 x 100 in) Aperture area: 6 x 4 cm (2.25 x 1.5 in) Channel bag: 62 x 40 cm (24 x in) Capacity: 1000 ml Non-Woven Full Body Aperture Overall size: 165 x 254 cm (65 x 100 in) Aperture area: 6 x 4 cm (2.25 x 1.5 in) Non-Woven Full Body Incise Overall size: 140 x 244 cm (55 x 96 in) Incise area: 9 x 11.5 cm (3 1/2 x 4 1/2 in) Capacity: 500 ml Non-Woven Full Body Aperture Overall size: 140 x 244 cm (55 x 96 in) Aperture area: 5 x 7.5 cm (2 x 3 in) Capacity: 500 ml Tenting band forms to lift drape off patient s mouth and nose for enhanced comfort. 10 per pkg 10 per pkg 10 per pkg 10 per pkg 10 per pkg 10 per pkg Cataract Surgery - Drapes and Fluid Collectors Includes: 2 - Attached fluid collection bags (left and right eye) 1 - Adhesive wick 1 - Adhesive wipe 1 - Corneal light shield 1 - Tenting band 27
29 Cataract Surgery Drapes and Fluid Collectors BD Visidrape Outpatient Surgery Drapes Include an attached fluid collection bag and wick (reference and without wick) to remove blood and fluid from the surgical area. Non-woven drapes are lightweight and breathable for optimum patient comfort. They are low linting and moisture resistant to keep patient dry. Embossed plastic drapes are made of translucent non-glare material. They are impermeable to moisture yet light weight to keep patient dry and comfortable. Cataract Surgery - Drapes and Fluid Collectors The and have a special fluid collection bag with channels that better direct fluid into bag Non-Woven Incise Overall size: Incise area: Fluid collection bag with channels: Capacity: Non-Woven Aperture Overall size: Aperture area: Fluid collection bag with channels: Capacity: Non-Woven Incise Overall size: x 127 cm (40 x 50 in) Incise area: 9 x 11.5 cm (3 1/2 x 4 1/2 in) Fluid collection bag: 15.2 x 16.5 (6 x 6 1/2 in) Capacity: 250 ml Non-Woven Aperture Overall size: x 127 cm (40 x 50 in) Aperture area: 5 x 7.5 cm (2 x 3 in) Fluid collection bag: 15.2 x 16.5 (6 x 6 1/2 in) Capacity: 250 ml Embossed Plastic Incise Overall size: x 127 cm (40 x 50 in) Incise area: 9 x 11.5 cm (3 1/2 x 4 1/2 in) Fluid collection bag: 15.2 x 16.5 (6 x 6 1/2 in) Capacity: 250 ml Embossed Plastic Aperture Overall size: x 127 cm (40 x 50 in) Aperture area: 5 x 7.5 cm (2 x 3 in) Fluid collection bag: 15.2 x 16.5 (6 x 6 1/2 in) Capacity: 250 ml Non-Woven Half Body Incise Overall size: 165 x 183 cm (65 x 72 in) Incise area: 9 x 11 cm (3.5 x 4 in) Channel bag: 62 x 40 cm (24 x in) Capacity: 1000 ml 140 x 127 cm (55 x 50 in) 9 x 11.5 cm (3 1/2 x 4 1/2 in) 14.6 x 25.4 cm (5 3/4 x 10 in) 500 ml 140 x 127 cm (55 x 50 in) 5 x 7.5 cm (2 x 3 in) 14.6 x 25.4 cm (5 3/4 x 10 in) 500 ml per pkg per pkg per pkg per pkg per pkg per pkg Non-Woven Half Body Aperture Overall size: 165 x 183 cm (65 x 72 in) Aperture area: 6 x 4 cm (2.25 x 1.5 in) Channel bag: 62 x 40 cm (24 x in) Capacity: 1000 ml per pkg per pkg 28
30 Cataract Surgery Eye Protection Products BD Visitec Corneal Light Shields Corneal Light Shield [Hessburg] 8.5 mm diameter,.50 mm thick Opaque blue silicone protects the retina from operating microscope light. Small ridge around edge allows easy placement and removal. Will not adhere to cornea Corneal Light Shield 8 mm diameter PVA absorbent pad. Soft, porous structure protects the retina from operating microscope light. Contains no cellulose and does not leave lint or debris. Upon moistening, shield becomes soft and conforms to shape of cornea. Keeps cornea moist. Easy to remove. BD Visitec Eye Patches ProOphta S Eye Patch Clear window dressing protects the eye while allowing the patient to see and permits examination without removing the dressing. Blinking is unimpaired. Indicated for use after cataract, corneal and ptosis operations; also for lagophthalmos and dry eyes. Non-sterile BD Visitec Eye Shields Eye Shield (Left/Right) 8.5 x 6.5 cm (3 1/2 x 2 1/2 in) Flexible eye shield with ventilation holes. Shaped to fit the right or left eye for protection and comfort. Smooth edges do not require a cover. Individually sterile packed Eye Shield (Left) Eye Shield (Right) Universal Eye Shield 7.5 x 6.5 cm (3 x 2 1/2 in) Clear, lightweight plastic. Features smooth edges and ventilation holes for patient comfort. For use on left or right eye. 20 per box 50 per box 25 left/25 right per box 50 per box 50 per box Cataract Surgery - Eye Protection Products 50 per box Universal Pediatric Eye Shield 5.1 x 4.1 cm (2 x 1 5/8 in) Clear, lightweight plastic. Features smooth edges and ventilation holes for patient comfort. For use on left or right eye. 2 29
31 Cataract Surgery Knives and Blades BD Beaver Accurate Depth Knives INITIAL GROOVE KNIVES AND BLADES Featuring enhanced sharpness to create smooth, consistent incisions, the BD Beaver Accurate Depth Knife is available in a broad range of sizes to address both arcuate and clear corneal groove incision needs. Pre-set guard provides accuracy for precise depth incisions. Bi-directional blade can cut left or right to match surgeon preference and maintain incisional plane. One-sided guard enhances visibility of the incision. Depth Knives Cataract Surgery - Knives and Blades 250 micron micron micron micron micron micron BD Atomic Edge Accurate Depth Knives BD Atomic Edge Limbal Relaxing Incision Knives Description BD Beaverguard Guarded Depth Blades Preset to ensure uniform depth control. Depth Knives 250 micron micron micron micron micron Guarded Depth Blades.35 mm mm Available soon See page 38 for BD Beaver handles. Description Knives 550 micron micron micron micron BD Beaver Mini-Blade Blades and Knife Available soon Available in a variety of designs to meet all small incision and excision needs. Beaverguard Guarded Depth Rounded tip, sharp on one side, blade 24 per box Sharp all around, 180 cutting surface, double bevel blade, straight 6 per box Smaller alternative to #11 general blade 24 per box Sharp all around, 180 cutting surface, double bevel blade, 60 6 per box Smaller alternative to #15 general blade 24 per box Sharp all around, 180 cutting surface, double bevel knife, straight See page 38 for BD Beaver handles.
32 Cataract Surgery Knives and Blades SCLERAL KNIVES AND BLADES BD Pocket Scleral Knives and Blades Ideal for short scleral tunnel incisions and incisions into the trabecular meshwork. Matte finish reduces glare from microscope light. Description Knives Blades 2.25 mm, 60, Bevel Up mm, 60, Bevel Down mm, Double Bevel Knife Blade See page 38 for BD Beaver handles. BD Sclerotome Blade and Knife BD Sclerotome is a versatile blade suitable for glaucoma and retinal procedures. The BD Sclerotome knife has a smaller cutting edge and improved sharpness for a more precise, controlled dissection. Description Knife Blade Multi-sided, Sharp all around Multi-sided, Sharp all around, smaller cutting edge See page 38 for BD Beaver handles. BD Beaver Cataract Blades Designed for ICCE and ECCE. Size Blades 19.0 mm x 1.4 mm mm x 1.7 mm mm x 2.2 mm mm x 2.2 mm See page 38 for BD Beaver handles. CATARACT AND KERATOME BLADES BD Beaver Keratome Blades Angled 45. Size Blades 2.3 mm Sclerotome Cataract Surgery - Knives and Blades BD EdgeAhead Circular Knives Circular knives have a 260 cutting edge for even incisions reducing post-op astigmatism. Also useful for trabeculotomy, DCR procedures, and vitreoretinal scleral dissection. Matte finish reduces glare from microscope light. Description Knives 2.25 mm mm, 60, 3 mm from tip mm, 60, 6 mm from tip
33 Cataract Surgery Knives and Blades CRESCENT KNIVES AND BLADES BD Xstar Crescent Knives Available straight, bevel up or bevel down for flexibility to create optimal tunnel architecture. Matte finish reduces glare from microscope light, made from round stock. Xstar Cataract Surgery - Knives and Blades BD EdgeAhead Crescent Knives Crescent knives have a rounded tip for even incisions reducing post-op astigmatism. Also useful for trabeculotomy, DCR procedures, and vitreoretinal scleral dissection. Matte finish reduces glare from microscope light, made from flat stock. BD Beaver Xstar Safety Crescent Knife The BD Beaver Xstar Safety Crescent Knife is 55 with the bevel up, designed for optimal tunnel architecture. BD Beaver Pocket Crescent Blades Tapered end and smaller tip improve blade maneuverability when creating a tunnel. Sharp all around crescent shape and matte finish for better visibility, made from flat stock. Straight Width Xstar Knife Pocket Blade EdgeAhead Knife 2.25 mm mm Angled Width/ Xstar Xstar EdgeAhead EdgeAhead Pocket Xstar Angle Knife Knife Knife Knives Blade Safety Knife Bevel Up Bevel Down Bevel Down Bevel Up Bevel Up Bevel Up EdgeAhead Pocket Blade 2.5 mm/ mm/ mm/ See page 38 for BD Beaver handles. 32
34 Cataract Surgery Knives and Blades IMPLANT KNIVES AND BLADES BD Xstar Implant Knives Designed specifically for widening the incision for lens implantation. Matte finish reduces glare from microscope light, made from round stock. Xstar BD EdgeAhead Intraocular Lens (IOL) Knives Designed to enlarge a small incision for implantation of IOL after removal of the crystalline lens. Sides are sharp and tip is blunt. Matte finish reduces glare from microscope light, made from flat stock. BD Beaver Implant Blades Implant blades put precision and control in your hands. Matte finish reduces glare from microscope light. See page 38 for BD Beaver handles. Straight Width Xstar Knives 3.2 mm 3.5 mm mm 4.1 mm mm 5.2 mm mm 6.2 mm Angled BD Beaver Lamellar Blades A flat, polished undersurface makes these sharp-all-around blades ideal for undermining and for scleral pocket incisions. Width Xstar EdgeAhead Beaver Beaver Knives Knives Blade Blade Bevel Up/45 Bevel Up/40 Bevel Up/45 Bevel Down/ mm mm mm mm mm mm mm mm EdgeAhead Beaver Blade Cataract Surgery - Knives and Blades Description Blades Straight , Bevel Up See page 38 for BD Beaver handles. 33
Product Catalog. The Finest Single-Use Products for Today s Ophthalmic Surgery
Product Catalog The Finest Single-Use Products for Today s Ophthalmic Surgery Hurricane Medical was established in 1999 to provide ready-to-use surgical products and superior customer service to ophthalmic
More informationBeaver-Visitec International Ophthalmic and Microsurgical Product Catalogue
Beaver-Visitec International Ophthalmic and Microsurgical Product Catalogue Beaver-Visitec International, Ltd. 85c Park Drive, Milton Park, Abingdon, Oxfordshire OX14 4RY Tel: 44.1865.601.256 Fax: 44.1865.595.761
More informationThe specialists in single-use. Refractive
The specialists in single-use. Refractive Flap Separators/Elevators 77 LASIK Flap Elevator, Curved, 8mm 0.mm 0.5mm Tip, Curved 8mm Tapered Shaft at 90. 8mm 78 435 LASIK Flap Elevator, Straight, 8mm LASIK
More informationGLOBE NEWS. LASIK - What are my Choices? A COMPREHENSIVE SELECTION OF INSTRUMENTS FROM KATENA. Katzen Flap Unzipper FOR OPHTHALMIC PROFESSIONALS
GLOBE NEWS VOLUME 9 NUMBER 1 FOR OPHTHALMIC PROFESSIONALS LASIK - What are my Choices? A COMPREHENSIVE SELECTION OF INSTRUMENTS FROM KATENA The growth of LASIK surgery has dramatically increased during
More informationThe specialists in single-use. Phaco
The specialists in single-use. Phaco Malosa Phaco Pack 22 Pha 0.3mm.5mm Chopper Tip 0.5mm 0.65mm Mushroom Tip, 0.5mm 45 Angled Shafts. 52mm Handle 22 Capsulorhexis - Straight/Sharp 0.6mm 0.3mm Sharp Tips,
More informationBeaver-Visitec International. Ophthalmic and Microsurgical Product Catalog
Beaver-Visitec International Ophthalmic and Microsurgical Product Catalog Eye Spears Beaver-Visitec offers an extensive range of Eye Spears that are designed to meet the needs of clinicians for a variety
More informationThe specialists in single-use. LASIK/LASEK/PRK/Cross-Linking
The specialists in single-use. LASIK/LASEK/PRK/Cross-Linking Flap Separators/Elevators 77 LASIK Flap Elevator, Curved, 8mm 0.2mm 0.5mm Tip, Curved 8mm Tapered Shaft at 90. 8mm 78 435 LASIK Flap Elevator,
More informationSterile, Single-use, Instruments
Sterile, Single-use, Instruments Surgitrac instruments, single-use ophthalmic and refractive instruments. Single-use instruments look and feel like a reusable, but offer so much more: Safer: sterile, ready-to-use,
More informationDuckworth & Kent Ophthalmic Titanium Surgical Instruments
Duckworth & Kent Ophthalmic Titanium Surgical Instruments at the Leading Edge LASIK Instruments Duckworth and Kent is the first and original manufacturer and supplier of titanium surgical instruments.
More informationFEMTO-CATARACT INSTRUMENTS Speculum SPECULUM FOR DOCKING STATION
Speculum SPECULUM FOR DOCKING STATION TM Slade- Murdoch Speculum: AE-1033 Blades specially curved to accommodate Femtosecond laser docking station Self locking mechanism for quick installation and removal
More informationLASIK & LASEK. at the Leading Edge. Including Instruments for Femto Second Laser
Established in 1959 LASIK & LASEK DK Stein Utility Forceps Gulani LASIK Marker Cionni Femto Speculum DK Femto Flap Lifter and Retreatment Spatula Including Instruments for Femto Second Laser 7 Marquis
More informationIVALON Ophthalmic. IVALON Ophthalmic Products
IVALON Ophthalmic IVALON Ophthalmic Products IVALON Ophthalmic products are constructed using a highly absorbent, unique hydroxylated polyvinyl acetal (PVAc) sponge. Several densities of sponge are available
More informationMARKERS AND REFRACTIVE
Optical Zone Markers... 1 Corneal Markers... 1 Centration Marker... 1 Corneal Transplant Markers... 2 Glaucoma Markers... 2 LRI/Toric Markers... 2 Lasik Markers... 4 PRK, LASIK, LASEK, IntraLasik and Flap
More informationInstruments for Femtosecond Laser
Instruments for Femtosecond Laser DK Stein Utility Forceps Gulani LASIK Marker R J Mackool Femtosecond Laser Speculum DK Femto Flap Lifter and Retreatment Spatula Including LASIK & LASEK Specula
More informationiocutouchtm for ipad Contents of Videos and Still Images Anatomy 906. Normal Eye and Orbit - no labels 907. Normal Eye and Orbit - with labels
iocutouchtm for ipad Contents of Videos and Still Images Anatomy 906. Normal Eye and Orbit - no labels 907. Normal Eye and Orbit - with labels Normal Eye 474. Normal Eye overview 476. Cornea - overview
More informationSingle-Use Surgical Instruments
Single-Use Surgical Instruments Ophthalmology 2011/2012 Your route to single-use instruments Malosa Medical UK Malosa UK Facility Malosa Medical China New Factory Facility 100% Malosa owned manufacturing
More informationSurgical scissors and forceps Product List
Surgical scissors and forceps Product List Sr. No Items Picture of Product Product specification 1 Grasping forceps-- 5 MM Grasping forceps are used to remove stones and retrieve foreign objects under
More informationMicro Coaxial Cataract Surgery
Where QUALITY meets INNOVATION to OPTIMIZE OUTCOMES in sub 2.4mm cataract surgery Micro Coaxial Cataract Surgery TABLE OF CONTENTS MICRO COAXIAL CATARACT I II III IV V VI VII VIII I Incision Offers a selection
More informationCataracts. Cataract and Primary Eye Care Service...215-928-3041. Main Number...215-928-3000. Physician Referral...1-877-AT-WILLS 1-877-289-4557
Main Number...215-928-3000 Physician Referral...1-877-AT-WILLS 1-877-289-4557 Emergency Service...215-503-8080 Cataract and Primary Eye Care Service...215-928-3041 Retina Service... 215-928-3300 Cataract
More informationDescemet s Stripping Automated Endothelial Keratoplasty (DSAEK)
Descemet s Stripping Automated Endothelial Keratoplasty (DSAEK) John D. Goosey, MD Introduction DSAEK is a corneal transplant technique where the unhealthy, diseased, posterior portion of a patient s cornea
More informationManagement of Astigmatism in Cataract Surgery
Management of Astigmatism in Cataract Surgery Jonathan B. Rubenstein, M Vice- Chairman and eutsch Family Professor of Ophthalmology irector of Refractive Surgery Rush University Medical Center Financial
More informationSelection & Use of Surgical Needles
Selection & Use of Surgical Needles EThALLOy * INTELLIGENT GEOMETRy ADVANCED NEEDLE COATING The Selection & Use of Surgical Needles EThICON Products needles are manufactured in a wide range of types, shapes,
More informationMinimally Invasive Surgery: Femtosecond Lasers and Other Innovative Microsurgical Techniques
Minimally Invasive Surgery: Femtosecond Lasers and Other Innovative Microsurgical Techniques Julio Narváez MD Associate Professor of Ophthalmology Loma Linda University Non-Refractive Applications of Femtosecond
More informationLASER INSTRUMENTATION
509201 509202 509204 509205 509206 509207 509203 LASER INSTRUMENTATION Laser Instrumentation (Ebonized) Ossoff-Karlan Laser Instruments Pilling recoends the Ossoff-Karlan Laser Instrumentation presented
More informationMIN Set. Instruments for Minimally Invasive Neurosurgery. Aesculap Neurosurgery
MIN Set Instruments for Minimally Invasive Neurosurgery Aesculap Neurosurgery MIN Set Features Fine instrument tips Especially important when working in very narrow spaces and close to sensitive structures.
More informationAcrySof IQ Toric IOL (SN6ATT) Surgeon Keys for Success & Acknowledgement
AcrySof IQ Toric IOL (SN6ATT) Surgeon Keys for Success & Acknowledgement Alcon Laboratories, Inc is pleased to announce the availability of the AcrySof IQ Toric intraocular lens, and delighted that you
More informationApplications in Dermatology, Dentistry and LASIK Eye Surgery using LASERs
Applications in Dermatology, Dentistry and LASIK Eye Surgery using LASERs http://www.medispainstitute.com/menu_laser_tattoo.html http://www.life123.com/bm.pix/bigstockphoto_close_up_of_eye_surgery_catar_2264267.s600x600.jpg
More informationCataract Surgery after Myopic Refractive Procedures. Ray Guard Eye Center Huang Wei-Jen, MD
Cataract Surgery after Myopic Refractive Procedures Ray Guard Eye Center Huang Wei-Jen, MD Financial Disclosures : * No financial interest on products mentioned Cataract Surgery after Myopic Refractive
More informationWhat is the main target for all phaco surgeons?
CORRECTION C O OF ASTIGMATISM DURING CATARACT SURGERY Abdallah dllh K. Hassouna, M.D. Sherein S. Wahba, M.D. Ain Shams University 2009 Main target What is the main target for all phaco surgeons? Main Target
More informationSpecula. Opening the eyes of the world. www.duckworth-and-kent.com
Specula Opening the eyes of the world Variations of Specula Single Piece All Duckworth & Kent single piece specula are made from a single piece of titanium. There are no joints or welds which can create
More informationTREATMENT 1. Control bleeding by applying pressure over wound with Gauze Pads (Surgical Supply-4). 2. Contact Surgeon for laceration repair options.
Page 1 of 8 pages NOTE Contact Surgeon before giving any medication marked with an asterisk. In an emergency or during Loss of Signal, begin appropriate treatment; then call Surgeon as soon as possible.
More informationPlacement of Epidural Catheter for Pain Management Shane Bateman DVM, DVSc, DACVECC
Placement of Epidural Catheter for Pain Management Shane Bateman DVM, DVSc, DACVECC Indications: Patients with severe abdominal or pelvic origin pain that is poorly responsive to other analgesic modalities.
More informationSMALL INCISION CATARACT SURGERY
Chapter - 6 SMALL INCISION CATARACT SURGERY The place and relevance of manual small incision cataract surgery Modern cataract surgery aims to achieve a better unaided visual acuity with rapid post surgical
More informationCONSENT FOR CATARACT SURGERY
CONSENT FOR CATARACT SURGERY INTRODUCTION The natural crystalline lens can become cloudy due to aging, trauma, disease or medications. This condition is called a cataract. When cataracts become visually
More informationHow To Improve Eye Acuity With Laser Vision Correction
The future of cataract surgery has arrived A cataract clouding of the eye s natural lens as a result of aging or injury is the leading cause of preventable blindness worldwide. 1 Cataract surgery is one
More informationTHE EYES IN MARFAN SYNDROME
THE EYES IN MARFAN SYNDROME Marfan syndrome and some related disorders can affect the eyes in many ways, causing dislocated lenses and other eye problems that can affect your sight. Except for dislocated
More informationPHaSES: Practical Hands-on Surgical Education System
U.S. Toll Free 866-GOLIMBS PHaSES Range PHaSES: Practical Hands-on Surgical Education System Limbs & Things is pleased to introduce the PHaSES Range. The range is based upon our well known basic & general
More informationCataract Surgery Patient Information
Cataract Patient Information 1. Within the human eye, there is a normal structure called the lens. In youth, this lens is clear, and light rays pass through and are focused by this lens as well as the
More informationKensington Eye Center 4701 Randolph Road, #G-2 Rockville, MD 20852 (301) 881-5701 www.keceyes.com
Kensington Eye Center 4701 Randolph Road, #G-2 Rockville, MD 20852 (301) 881-5701 www.keceyes.com Natasha L. Herz, MD INFORMED CONSENT FOR DESCEMET S STRIPPING and AUTOMATED ENDOTHELIAL KERATOPLASTY (DSAEK)
More informationThe cataract laser technology of tomorrow is here for you today.
The cataract laser technology of tomorrow is here for you today. See inside to learn about all your exciting new options Thanks to new advancements, this is a great time to have cataract surgery Laser
More informationPhacoemulsification Surgical Product Catalog
Phacoemulsification Surgical Product Catalog WHITESTAR Signature System With Fusion Fluidics Another revolutionary innovation from the pioneers in phaco technology The WHITESTAR Signature System is a premium
More informationCurtin G. Kelley, M.D. Director of Vision Correction Surgery Arena Eye Surgeons Associate Clinical Professor of Ophthalmology The Ohio State
Curtin G. Kelley, M.D. Director of Vision Correction Surgery Arena Eye Surgeons Associate Clinical Professor of Ophthalmology The Ohio State University Columbus, Ohio Refractive Errors Myopia (nearsightedness)
More informationDescemet s Stripping Endothelial Keratoplasty (DSEK)
Descemet s Stripping Endothelial Keratoplasty (DSEK) Your doctor has decided that you will benefit from a corneal transplant operation. This handout will explain your options to you. It explains the differences
More informationInformation For Consent For Cataract Surgery
Information For Consent For Cataract Surgery Your Ophthalmologist has diagnosed you with a visually significant cataract. The following handout will explain your condition and give you the information
More informationCONSENT FOR CATARACT SURGERY REQUEST FOR SURGICAL OPERATION / PROCEDURE AND ANAESTHETIC
CONSENT FOR CATARACT SURGERY REQUEST FOR SURGICAL OPERATION / PROCEDURE AND ANAESTHETIC Your doctor has indicated that the condition of your eye appears stable and your cataract surgery and/or implantation
More informationComparison of astigmatism following manual small incision cataract surgery: superior versus temporal approach
Original articles Comparison of astigmatism following manual small incision cataract surgery: superior versus temporal approach Malik VK 1, Kumar S 2, Kamboj R 1, Jain C 1, Jain K 1, Kumar S 1 1 Department
More informationWelcome to the Verisyse Seminar
Patient Seminar Welcome to the Verisyse Seminar Today we ll answer some of the most common questions about the Verisyse Phakic Intraocular Lens (IOL) including: Who is a candidate How the procedure is
More informationINFORMED CONSENT FOR PHAKIC IMPLANT SURGERY
INFORMED CONSENT FOR PHAKIC IMPLANT SURGERY INTRODUCTION This information is being provided to you so that you can make an informed decision about having eye surgery to reduce or eliminate your nearsightedness.
More informationCatalogue 2014 www.duckworth-and-kent.com
Catalogue 2014 www.duckworth-and-kent.com Duckworth & Kent All schematic line drawings, photographs and copy in this catalogue are fully protected by copyright. No part of this catalogue may be reproduced
More informationSHEEP EYE DISSECTION PROCEDURES
SHEEP EYE DISSECTION PROCEDURES The anatomy of the human eye can be better shown and understood by the actual dissection of an eye. One eye of choice for dissection, that closely resembles the human eye,
More informationWHAT IS A CATARACT, AND HOW IS IT TREATED?
4089 TAMIAMI TRAIL NORTH SUITE A103 NAPLES, FL 34103 TELEPHONE (239) 262-2020 FAX (239) 435-1084 DOES THE PATIENT NEED OR WANT A TRANSLATOR, INTERPRETOR OR READER? YES NO TO THE PATIENT: You have the right,
More informationSome of the ophthalmic surgeries performed at the DMV Center.
Some of the ophthalmic surgeries performed at the DMV Center. This document presents some types of the surgeries performed by the ophthalmology service at the DMV veterinary center as well as the equipment
More informationLaser Assisted Cataract Surgery
Laser Assisted Cataract Surgery: The New Frontier The Joseph H. Wyatt DO Lecture Brian D. Ranelle D.O. Texas Eye and Laser Center Ft. Worth and Hurst, Texas Laser Assisted Cataract Surgery The New Frontier
More informationTucson Eye Care, PC. Informed Consent for Cataract Surgery And/Or Implantation of an Intraocular Lens
Tucson Eye Care, PC Informed Consent for Cataract Surgery And/Or Implantation of an Intraocular Lens INTRODUCTION This information is provided so that you may make an informed decision about having eye
More informationHAND INSTRUMENTS. HiQ+ Monopolar Hand Instruments Needle Holders Suction and Irrigation Monopolar HF Electrodes. THE HiQ+ SERIES
HAND INSTRUMENTS HiQ+ Monopolar Hand Instruments Needle Holders Suction and Irrigation Monopolar HF Electrodes THE HiQ+ SERIES CONTENTS FORM FOLLOWS FUNCTION FOLLOWS YOUR NEEDS HiQ+ Monopolar and Standard...4
More informationINFORMED CONSENT FOR PHAKIC LENS IMPLANT SURGERY
INTRODUCTION INFORMED CONSENT FOR PHAKIC LENS IMPLANT SURGERY This information is being provided to you so that you can make an informed decision about having eye surgery to reduce or eliminate your nearsightedness.
More informationLASIK. What is LASIK? Eye Words to Know. Who is a good candidate for LASIK?
2014 2015 LASIK What is LASIK? LASIK (laser in situ keratomileusis) is a type of refractive surgery. This kind of surgery uses a laser to treat vision problems caused by refractive errors. You have a refractive
More informationInformed Consent for Refractive Lens Exchange (Clear Lens Replacement)
Mark Packer, M.D. Informed Consent for Refractive Lens Exchange (Clear Lens Replacement) This surgery involves the removal of the natural lens of my eye, even though it is not a cataract. The natural lens
More informationFeature. Femto Laser Cataract: Avoiding Complications Christopher Kent, Senior Editor. As more surgeons explore the
Femto Laser Cataract: Avoiding Complications Christopher Kent, Senior Editor Like every new surgery, this one is associated with unique potential problems. Here s how to keep things going smoothly. As
More informationInformed Consent for Cataract Surgery and/or Implantation of an Intraocular Lens (IOL)
Bruce H. Brumm, MD, PC 6751 North 72 nd Street, Ste 105 Omaha, NE 68122 (402) 572-2020 800-775-5909 www.brummeye.com Informed Consent for Cataract Surgery and/or Implantation of an Intraocular Lens (IOL)
More informationHydrogel Competence in Eye Surgery
Hydrogel Competence in Eye Surgery Self-inflating tissue expander osmed self-inflating tissue expanders are made of a specially developed hydrogel that uses the osmotic principle to gain volume. These
More informationBACKGROUND INFORMATION AND INFORMED CONSENT FOR CATARACT SURGERY AND IMPLANTATION OF AN INTRAOCULAR LENS
OMNI EYE SPECIALISTS A Madison Street Company Proudly Owned by Employees Specializing in Medical and Surgical Care of the Eye 55 Madison St, Suite 355 Denver CO 80206 303-377-2020 800-GO-2-OMNI www.omnieye.com
More informationThe «three-in-one» Microkeratome for traditional LASIK, EPI-LASIK, and anterior and posterior Lamellar Keratoplasty
The «three-in-one» Microkeratome for traditional LASIK, EPI-LASIK, and anterior and posterior Lamellar Keratoplasty Ziemer Group We develop and produce diagnostic and surgical products for the ophthalmic
More informationYour one stop vision centre Our ophthalmic centre offers comprehensive eye management, which includes medical,
sight see OLYMPIA EYE & LASER CENTRE Your one stop vision centre Our ophthalmic centre offers comprehensive eye management, which includes medical, At the Olympia Eye & Laser Centre, our vision is to improve
More informationFitting Guide. Dallas 800-366-3933 Denver 800-362-4233 Tulsa 800-685-5367
Fitting Guide Dallas 800-366-3933 Denver 800-362-4233 Tulsa 800-685-5367 Sagittal Depth Fitting the Jupiter lens design is based upon sagittal depth. Relative sagittal depth is not just the steepness of
More informationProviding Optimal Optics For Your Astigmatic Cataract Patients. While the cornea remains relatively stable and prolate throughout life
Providing Optimal Optics For Your Astigmatic Cataract Patients David I. Geffen, OD, FAAO Why keep the crystalline lens? While the cornea remains relatively stable and prolate throughout life Unless we
More information...You Need to know about
What......You Need to know about LASIK Our Eyes Eyes are the windows to our world. They are so important to us that for many years we have looked for better ways to fix visual problems and improve our
More informationSUCTION, ASPIRATING TUBES
162300 536204 162345 162301 (shown twice size) Yankauer Suction Tubes YANKAUER SUCTION TUBES Standard adult size. 10 mm diameter. Tip has 2 mm central opening and four 2 mm side openings. 162300 12 1/2"
More informationA STUDY ON SURGICALLY INDUCED ASTIGMATISM FOLLOWING SMALL INCISION CATARACT SURGERY
A STUDY ON SURGICALLY INDUCED ASTIGMATISM FOLLOWING SMALL INCISION CATARACT SURGERY *Vinay KV 1, Sudheendra AN 2, Vishal K 3 and Beena DN 4 1, 3 Department of Anatomy, K. S. Hegde Medical Academy, Mangalore,
More informationEye Injuries. The Eyes The eyes are sophisticated organs. They collect light and focus it on the back of the eye, allowing us to see.
Eye Injuries Introduction The design of your face helps protect your eyes from injury. But injuries can still damage your eyes. Sometimes injuries are severe enough that you could lose your vision. Most
More informationUniversal TM Surgical Eye Care Products
Universal TM Surgical Eye Care Products Refractive Instrument B. Graczyk, Inc. 61 Brookside Drive Glendale Heights, IL 60139 USA Phone: 630-871-20 Fax: 630-871-7620 Email: graczykinc@aol.com Web Site www.keratomeblades.com
More informationLASIK What is LASIK? Am I a good candidate for LASIK? What happens before surgery? How is LASIK done?
LASIK What is LASIK? Laser assisted in situ keratomileusis, or LASIK, is an outpatient surgical procedure used to treat myopia (nearsightedness), hyperopia (farsightedness), and astigmatism. With LASIK,
More informationZimmer DeNovo NT Natural Tissue Graft
Zimmer DeNovo NT Natural Tissue Graft Surgical Technique Biologic treatment for early intervention and cartilage repair. Overview DeNovo NT Natural Tissue Graft (Fig. 1) is an off-the-shelf human tissue,
More informationNEW HORIZONS IN CORNEAL SURGERY VERSATILE FEMTOSECOND LASER WORKSTATION WE FOCUS ON PERFECTION
NEW HORIZONS VERSATILE FEMTOSECOND IN CORNEAL LASER WORKSTATION SURGERY WE FOCUS ON PERFECTION ADVANCED FEMTOSECOND LASER TECHNOLOGY COMMITTED TO VERSATILITY > ONE SYSTEM FOR ALL FEMTO-APPLICATIONS > ANATOMICALLY
More informationScout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.
Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery. Technique Guide Instruments and implants approved by the AO Foundation Table of Contents Introduction Scout Vessel Guard 2
More informationAdvanced Eyecare of Orange County Kim Doan, M.D. Eye Physician & Surgeon
Advanced Eyecare of Orange County Kim Doan, M.D. Eye Physician & Surgeon Patient Information Sheet: Cataract Surgery And/Or Implantation of an Intraocular Lens This information is given to you so that
More informationVISION PATTERN. What Can you Expect from the ReSTOR procedure?
RESTOR Presbyopia is the normal aging process that everyone experiences over the age of 40 which affects near vision. This usually results in the need for reading glasses or bifocals. The crystalline lens
More informationExplanation of the Procedure
Informed Consent Cataract Surgery with Intraocular Lens Implant Please initial below indicating that you have read and understand each section Introduction The internal lens of the eye can become cloudy
More informationfemtosecond laser platform Exceptional versatility without compromise
Introducing the VICTUS femtosecond laser platform Exceptional versatility without compromise FEMTOSECOND TECHNOLOGY that empowers Introducing VICTUS the first femtosecond laser capable of exceptional performance
More informationVerisyse Phakic IOL. Facts You Need to Know About Implantation of the Verisyse Phakic IOL (-5 to -20 D) for the Correction of Myopia (Nearsightedness)
Verisyse Phakic IOL Facts You Need to Know About Implantation of the Verisyse Phakic IOL (-5 to -20 D) for the Correction of Myopia (Nearsightedness) Patient Information Brochure This brochure is designed
More informationInformed Consent For Cataract Surgery And/Or Implantation of an Intraocular Lens
Informed Consent For Cataract Surgery And/Or Implantation of an Intraocular Lens INTRODUCTION This information is given to you so that you can make an informed decision about having eye surgery. Take as
More informationHKSH Introduces New Femtosecond Laser Enhanced Refractive Cataract Surgery High Precision and Safety
For Immediate Release HKSH Introduces New Femtosecond Laser Enhanced Refractive Cataract Surgery High Precision and Safety (30 August, 2012 Hong Kong) Hong Kong Sanatorium & Hospital ( HKSH ) proudly announces
More informationIncision along Steep Axis
Toric IOL An option or a must? ~ 15% cataract surgical patients >1.5 D Options: spectacles, CLs, Incision along steep axis, LRI, AK, toric IOL, Excimer Laser or a combination Walter J. Stark, MD Professor
More informationLaser Refractive Cataract Surgery with the LenSx Laser
Laser Refractive Cataract Surgery with the LenSx Laser a Novartis company LenSx Laser 2 3 An Evolving Definition of Cataract Average Age of US Cataract Patient is Projected to Decline Today: earlier diagnosis
More informationOverview. Addressing Astigmatism with Toric IOL Implantation: Pre-Operative and Operative Considerations. Where are we now? How have we progressed?
Addressing Astigmatism with Toric IOL Implantation: Pre-Operative and Operative Considerations Jason Wang, M.D. Spring Symposium 2012 OMNI Eye Specialists / Spivack Vision Center March 3, 2012 Overview
More informationTable of Contents. Page. Introducing Crystalens 2. What is a cataract 3. How the eye works 4. Vision restoration options 5
P/N 50-0065, Revision B, p.1 PATIENT LABELING Table of Contents Introducing Crystalens 2 Page What is a cataract 3 How the eye works 4 Vision restoration options 5 Are you a candidate for the Crystalens?
More informationNick Strouthidis MBBS MD PhD FRCS FRCOphth FRANZCO CONSULTANT OPHTHALMIC SURGEON
TUBES/SHUNTS TUBES/SHUNTS Implantation of a glaucoma drainage device (GDD - also known as a tube or aqueous shunt) works by diverting aqueous from the front of the eye via a tube to a drainage plate stitched
More informationInformed Consent for Cataract Surgery or Clear Lens Extraction with Implantation of an Intraocular Lens
Informed Consent for Cataract Surgery or Clear Lens Extraction with Implantation of an Intraocular Lens Please read the following pages carefully, and initial and sign where indicated. Please do not sign
More informationInformed Consent for Refractive Lens Exchange (Clear Lens Replacement)
Drs. Fine, Hoffman and Packer, LLC PHYSICIANS AND SURGEONS, EyeMDs OPHTHALMOLOGY I. Howard Fine, M.D. Richard S. Hoffman, M.D. Mark Packer, M.D. 1550 Oak Street, Suite 5 www.finemd.com Eugene, OR 97401-7701
More informationSECTION. BD Medical Anesthesia Products - Trays 2014 2015. For additional product information, visit us online at www.bd.com
SECTION A2 BD Medical Anesthesia Products - Trays 2014 2015 For additional product information, visit us online at www.bd.com BD Combined Spinal and Epidural Trays 405815 1/1/2014 17 G x 3 1/2 in. BD Durasafe
More informationDr. Booth received his medical degree from the University of California: San Diego and his bachelor of science from Stanford University.
We've developed this handbook to help our patients become better informed about the entire process of laser vision correction. We hope you find it helpful and informative. Dr. Booth received his medical
More informationTrulign Toric Accommodating Intraocular Lenses PATIENT INFORMATION BROCHURE
Trulign Toric Accommodating Intraocular Lenses PATIENT INFORMATION BROCHURE Table of Contents Page Glossary 2 Introducing Trulign Toric Accommodating IOL 5 What is a cataract 5 What is corneal astigmatism
More informationCustom Cataract Surgery. Laser and Lens Options
Custom Cataract Surgery Laser and Lens Options What is a Cataract? More than fifty percent of people over the age of 60, and quite a few younger than that, suffer from cataracts. In fact, cataracts are
More informationTechnique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.
Technique Guide Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting. Table of Contents Introduction Reamer/ Irrigator/ Aspirator (RIA) 2 Indications 4 Surgical Technique Preparation
More informationThe LenSx Laser System. Discover the assurance of bladeless cataract surgery
g/ 14. The LenSx Laser System Discover the assurance of bladeless cataract surgery Don t let cataracts limit your lifestyle If you or someone you care for has been diagnosed with cataracts, you re certainly
More informationSurgical Coding Errors & English 101. Riva Lee Asbell. Fort Lauderdale, FL
Surgical Coding Errors & English 101 Riva Lee Asbell Fort Lauderdale, FL INTRODUCTION Many surgical coding mistakes result from misinterpretation of CPT (Current Procedural Terminology) wording. When the
More informationLaser Vision SA A trusted name in vision restoration. Blade Free Intralase Vision Correction Enhance your potential in just one day
Laser Vision SA A trusted name in vision restoration Blade Free Intralase Vision Correction Enhance your potential in just one day Imagine Opening your eyes to a clear, vibrant world Before you find your
More informationPATIENT GUIDE. Understand and care for your peripherally inserted central venous catheter (PICC). MEDICAL
PATIENT GUIDE Understand and care for your peripherally inserted central venous catheter (PICC). MEDICAL Introduction The following information is presented as a guideline for your reference. The best
More informationOpen and Endoscopic Forehead Lift. Plastic Surgery. For All Brow and Forehead Lift Procedures. Revolutionizing. Soft-Tissue Fixation
Plastic Surgery Open and Endoscopic Forehead Lift For All Brow and Forehead Lift Procedures Revolutionizing Soft-Tissue Fixation DESIGNED FOR SIMPLICITY AND PREDICTABILITY The versatile design can be applied
More informationMedicare Controversies in Cataract Coding One Consultant s Opinion. Riva Lee Asbell Philadelphia, PA
Medicare Controversies in Cataract Coding One Consultant s Opinion INTRODUCTION Riva Lee Asbell Philadelphia, PA It would seem that coding for cataract surgery is a straightforward affair not so at all.
More information