INSTALLATION & USER'S GUIDE

Size: px
Start display at page:

Download "INSTALLATION & USER'S GUIDE"

Transcription

1 RI-120 READER INTERFACE & Contact Expansion Module CEM-133 INSTALLATION & USER'S GUIDE Page 1 Copyright 2009, Access Specialties International, LLC All Rights Reserved

2 Table of contents Introduction pg 3 Specifications pg 3 Communications to Host (J4) pg 4 Installing a reader (J5) pg 4 Monitor Points (J6) pg 5 Output Point (J7) pg 6 Power Hook-up (J8) pg 6 Switch 1 (Degraded mode relay times) pg 7 Degraded Mode Explanation pg 7 Switch 2 (Degraded mode system codes) pg 8 System Code Reference (Table 8.1) pg 8 Contact Expansion Module (CEM 133) pg 9 Troubleshooting Techniques pg 11 Resetting the RI pg 12 General System Installation Diagram Figure 3.1 RI-120 Schematic Figure 3.2 Options for the Door Open Detect Monitor point Figure 5.1, 5.2 Page 2 Copyright 2009, Access Specialties International, LLC All Rights Reserved

3 INTRODUCTION The RI-120 is a Reader Interface Board that was designed to work with the IC-1600 Intelligent Controller and the Access Gold or ASI 200 software programs. It is capable of working with any wiegand output card-reader. The RI-120 transfers the data from the card reader up to the IC Four Monitoring points on the RI-120 also send signals up to the IC Two output relays on the RI-120 are provided for door access control. The CEM 133 Contact Expansion Module may be used with the RI-120 to expand the RI- 120 monitor and output points. Note: This document is valid only for RI-120 boards with firmware version 4.0 or higher. SPECIFICATIONS Card Technology: Barium Ferrite, Wiegand, Mag Stripe, Proximity Readers Momentary Door Unlocking: Switch selectable 2 to 16 seconds * Alarm Shunting: Switch selectable 6 to 48 seconds * Degraded Mode: Switch selectable system code 4 Monitored Input Points DOD, Exit Pushbutton,Tamper, User Definable 2 Controlled Output Points Go Relay & Shunt Relay Output Door Relay Contact Rating: Power Requirements: Operating Temperature: 120vac or 3A 60Hz at 1A, or 12 volts DC at 1 A -40 C to 75+ C *(RI-120 Unlocking and shunting time is 1 to 255 seconds when used with the ACCESS GOLD or ASI 2000 security systems.) Page 3 Copyright 2009, Access Specialties International, LLC All Rights Reserved

4 J4 HOST COMMUNICATIONS J4 provides the connections for communications to the host IC1600 or a CE Removable terminal blocks are provided for easy installation. The RI-120 requires a 4-wire connection to the host. The cable should be 22 gauge, shielded cable, consisting of 2 twisted pair, and all shields earth grounded at one end. The maximum distance is 2 miles from the IC A Channel expander (A channel expander multiplexes one channel on the IC-1600 into 16 ports) can extend that distance another 2 miles. Please note that the greater the distance, the greater the delay in transfer of data between the RI-120 and the IC Host ( a channel J4 - RI-120 or port ) Data + Pin #1 Data - Pin #2 Enable + Pin #3 Enable - Pin #4 J5 INSTALLING A READER The RI-120 provides 6 wire connections for a reader. The cable length from the reader to the RI-120 should not exceed 500 feet. The cable should be 22 gauge, shielded cable, consisting of 3 twisted pair, and all shields earth grounded at one end. The standard RI-120 will read 26 or 27 bit card formats (customized firmware for the RI-120 supports additional card formats). J5 provides the following connections for a reader: Compatible Reader J5 - RI-120 5VDC Pin #1 20VDC Pin #2 Ground Pin #3 LED Control Pin #4 Data 0 Pin #5 Data 1 Pin #6 Page 4 Copyright 2009, Access Specialties International, LLC All Rights Reserved

5 J6 INPUT CONNECTIONS Three dedicated software-defined inputs, along with one user definable input are available. The software defined monitoring points are for the EXIT push-button, DOOR OPEN DETECT monitor, and TAMPER detect (Note: a grounding connector is provided). All inputs have an LED indicator, which will emit light when the input contacts are closed. Label J6 - RI-120 Input 0 Pin #1 Door Open Detect/Forced Entry Detect * Input 1 Pin #2 Exit Push-button Input 2 Pin #3 Tamper Detect Input 3 Pin #4 User Definable Ground Pin #5 Ground Pin #6 All monitor points can be tied to alarms and conditional responses in the host access control software. The Door Open Detect input is explained in detail on figure 5.1 and 5.2 at the end of this guide. When the Exit Push-button s circuit is completed with the Ground, both the Go and the Shunt relay will fire. As long as the circuit is completed, the relays will stay energized. After the circuit is opened, the relays will stay energized for their respective times. Tamper detected message is reported when the RI-120 senses that the input went from a closed state to an open state. The User Definable monitor point can be used for anything from motion sensors, smoke detectors and other items. All User definable monitor points must be defined in the Monitor Points tab of the RI-120 device definition if they are to be used. If you issue a Go-Offline command to the RI-120, the RI-120 would not report any activity from all user-definable points. This includes the 1 point that comes with the RI-120 (input 3) and the 12 additional points on the CEM-133. To allow the activity to be reported again, issue a Go-Online command to the RI-120. Commanding Reader Interfaces to Go-Offline has nothing to do with communications, Degraded mode, or the software defined monitor points. It only tells the Reader Interface to ignore the activity on the User Defined inputs. This can be helpful when these points are tied to alarms and conditional responses. The RI-120 is capable of shunting the user-definable monitor points. If you choose No Shunt for the monitor point, then all activity for the monitor point is reported immediately. If you select the Open option and designate a shunt time, the system will wait for the duration of the shunt time to report it as an Open condition. This would be used when the monitor point is normally in a closed state. If the monitor point is normally open, you could select the Closed option to shunt. The amount of time that you specify for the condition to shunt is how long the system has to wait before reporting the Closed state to the host software. Page 5 Copyright 2009, Access Specialties International, LLC All Rights Reserved

6 J7 OUTPUT CONNECTIONS There are 2 dedicated relay outputs available: 1 GO relay and 1 SHUNT relay. Three additional user-definable outputs are available by adding a CEM-133. All output relays are rated at 28 VDC or 120VAC, with both voltages rated at 3A. Each output has an LED indicator that emits light when the relay is energized. When D10 emits light, this indicates that the Go relay is energized. When D11 emits light that indicates that the Shunt relay is energized. The Go time symbolizes the amount of time the user has to open the door. The Shunt time symbolizes the amount of time the user has to close the door. If the door is not closed within the shunt time, Door Held Open is reported in Monitor Activity of Access Gold or in Transaction Monitor of ASI Function J7 RI-120 Output 0 Common Pin #1 * Output 0 Normally Open Pin #2 Output 0 Normally Closed Pin #3 Output 1 Common Pin #4 * Output 1 Normally Open Pin #5 Output 1 Normally Closed Pin #6 * Note: Output 0 is the GO RELAY and Output 1 is the SHUNT RELAY. J8 POWER HOOK-UP J5 for the card reader should be connected before powering up the RI-120. J4 and J6 may be connected or disconnected while the RI-120 is powered up. Power J8 RI vac/12VDC+ Pin #1 12vac/12VDC- Pin #2 Ground Pin #3 Not Used Pin #4 Page 6 Copyright 2009, Access Specialties International, LLC All Rights Reserved

7 Switch 1 S1 controls the Go and Shunt Relays times when the Reader Interface is in Degraded Mode. Please note that if the reader has communications with the host, the Go and Shunt times can be set between 1 and 255 seconds. These times are set in Device Definition of the card reader, under Access Gold. For ASI 2000, they are set in the Device Center module. Pin 9 of S1 informs the RI-120 if there is a CEM-133 connected to it or not. RI-120 DIP Switch S1 Codes For the Go and Shunt times in Degraded Mode Go Time Position 1 Position 2 Position 3 2 Seconds Off Off Off 4 Off Off On 6 Off On Off 8 Off On On 10 On Off Off 12 On Off On 14 On On Off 16 On On On Shunt Time Position 4 Position 5 Position 6 6 Seconds Off Off Off 12 Off Off On 18 Off On Off 24 Off On On 30 On Off Off 36 On Off On 42 On On Off 48 On On On Switch 1 also controls the speed the RI-120 will attempt to communicate with the host, if the host panel supports multi-speed communications. Comm Speed Position 7 Position Baud Off Off 1200 Off On 2400 On Off Switch 2 S2 controls how the reader reacts in Degraded Mode If the RI-120 looses communication with the host IC-1600 (or CE-1600) for over fifteen seconds, the RI-120 goes into what is called Degraded Mode. In Degraded Mode the RI-120 compares the system code encoded on the card with the system code configured by setting Switch 2. If the system codes match, the RI-120 will energize the Go and Shunt Relays. Table 8.1 provides the appropriate settings for system codes 0 to 255 Page 7 Copyright 2009, Access Specialties International, LLC All Rights Reserved

8 Table 8.1 Legend: 0 = OFF 1 = ON System Code Settings - S2 SYS SYS SYS SYS Page 8 Copyright 2009, Access Specialties International, LLC All Rights Reserved

9 CEM-133 CONTACT EXPANSION MODULE OPTION (RI S1) To add 12 user-definable monitoring points and 3 controlled output relays, the CEM-133 must be attached on J1 of the RI-120. In order to activate the CEM- 133, position 9 on Switch 1 of the RI-120 board must be turned ON. When this position is turned OFF, the CEM-133 is not activated. INPUT CONNECTIONS (CEM J13 & J14) The CEM provides 12 additional input points to the RI-120 Reader Interface. An open contact will have VDC across it. A closed point will have approximately 10 ma of current. All of the input points for J14 are electrically common to ground. For more information on the usage of these inputs, see the user-definable section under the RI-120 inputs (J6). Function J13 - Pin# J14 - Pin# LED Input 4 Pin 1 Pin 1 D7 (NOTE: Inputs 0-3 Input 5 Pin 2 Pin 2 D8 are provided by the Input 6 Pin 3 Pin 3 D9 RI-120.) Input 7 Pin 4 Pin 4 D10 Input 8 Pin 5 Pin 5 D12 Input 9 Pin 6 Pin 6 D13 Input 10 Pin 7 Pin 7 D14 Input 11 Pin 8 Pin 8 D15 Input 12 Pin 9 Pin 9 D16 Input 13 Pin 10 Pin 10 D17 Input 14 Pin 11 Pin 11 D18 Input 15 Pin 12 Pin 12 D19 OUTPUT CONNECTIONS (J15) The CEM-133 provides three additional relay outputs. The output points are specified for 28VDC or 120VAC, with both voltages at 3A. Function J15 - Pin # LED Output 2 Common Pin 1 D4 (NOTE: Output Output 2 Normally Open Pin 2 points 0-1 are Output 2 Normally Closed Pin 3 provided by the Output 3 Common Pin 4 D5 RI-120.) Output 3 Normally Open Pin 5 Output 3 Normally Closed Pin 6 Output 4 Common Pin 7 D6 Output 4 Normally Open Pin 8 Output 4 Normally Closed Pin 9 Page 9 Copyright 2009, Access Specialties International, LLC All Rights Reserved

10 CEM-133 WIRING DIAGRAM & LEGEND Output 2 C. Output 2 N.O. Output 2 N.C. Output 3 C. Output 3 N.O. Output 3 N.C. Output 4 C. Output 4 N.O. Output 4 N.C J15 J12 (Not used) Note: C = Common NO = Normally Open NC = Normally Closed J14 Input 4 Input 5 Input 6 Input 7 Input 8 Input 9 Input 10 Input 11 Input 12 Input 13 Input 14 Input J13 Page 10 Copyright 2009, Access Specialties International, LLC All Rights Reserved

11 TROUBLESHOOTING TECHNIQUES Tech Tip 1 Determining whether the RI-120 is getting data from the card reader 1. Present the card to the card reader. 2. While presenting the card, watch LED D5 on the RI If LED D5 flashes once as the card is presented, that means that the card reader is successfully sending up the data to RI-120. Tech Tip 2 Visually checking if there is communications from the RI-120 to the IC- 1600/CE Access Gold /panelcom or ASI Launch/Panel Manager need to be running. 2. The device number or device name of the Reader Interface must be known. 3. Look up the Device number in Device Definitions. Find out what channel or port the RI-120 is connected to on the IC-1600 or CE Edit the IC-1600 and make sure that the channel is checked so the channel is ON. 5. Look at the channel (or port for a CE-1600) and verify that the Led is flashing (the more channels that are ON, the slower the LEDs will flash). Tech Tip 3 Checking the communications from the Software 1. Access Gold /panelcom or ASI Launch/Panel Manager need to be running. 2. Click on the Monitor activity button, in Access Gold, to watch the real time transactions. For ASI 2000, click on the Transaction Monitor module. 3. Transactions from other devices must be reporting. If nothing is being reported in the Monitor activity screen or Transaction Monitor, there may be a problem with panelcom or Panel Manager respectively. 4. Send a signal up to the RI-120. Either change the state of a monitor point or present a card to the reader. 5. In the system activity screen, the signal that was just sent up from the RI-120 should be reported. If nothing is reported then there is no communications to the host. Tech Tip 4 Finding out the encoded # of a card The Same steps in Tech Tip 3 can identify the encoded #. This procedure would be necessary if the number on the outside of the card (embossed #) is different from the encoded number, and there is not a reference sheet that tells the tech these numbers. Tech Tip 5 Finding out the Device # of a Reader Interface 1. The Same steps in Tech Tip 3 can be taken to identify the device # of an RI-120 (or any other unit). When sending the signals up from the RI-120 to the IC-1600 the appropriate messages ( Access Granted, Tamper Detected etc ) should be reported with a device # or device name. 2. You can look up the device # or device name under System Devices or Device Center. The Device Definitions provides important information on the RI-120. For example, the panel #, channel #, port #, Go and Shunt times etc 3. If there is not a device # assigned to the RI-120, the message Undefined Reader will report along with the channel and port # s. Page 11 Copyright 2009, Access Specialties International, LLC All Rights Reserved

12 Tech Tip 6 Replacing a bad Comm. 20 board. 1. Many times when communications is not functioning between the IC-1600 and the Reader Interface, the comm20 board has gone bad. 2. The comm20 board is the small circuit board that is upside down in reference to the RI To replace it, power down the RI The comm20 board has two J connections. J1 and J2. 5. The process for installing the comm20 board onto the RI-120 board is to connect the low number from the comm20 board to the low number on the RI-120. This process is the same for all of Access Specialties communications daughter boards and devices. 6. Power may now be reapplied. Resetting the Reader Interface Boards 1. Power down the Reader Interface board. 2. Turn off all of the dip-switches on both S1 and S2. 3. Turn Pin 7 & 8 on SW1 to the ON position. 4. Power up the Reader Interface Board. 5. Wait 5 seconds. 6. Power down the Reader Interface. 7. Put original settings back in the switches (go & shunt times, system code, and communications speed) and power up the RI-120 board. 8. The reader interface has now been reset. This procedure can be tried whenever a Reader Interface is not sending up the card Data to the IC-1600 This procedure is also the same process for all other Reader Interfaces (RI-110 & RI- 130) This procedure causes the Go relay to chatter during this process. This chattering verifies that the RI-120 is resetting itself. This procedure will reset the operating mode to whatever is set on SW1 pins 1, 2, and 3 as follows: New Mode Position 1 Position 2 Position 3 Card Only Off Off Off Card plus Pin Off Off On Card or Pin Off On Off This procedure will reset the programmed Go and Shunt times. To restore them you will have to edit the device in Access Gold or ASI-2000 and save it. Page 12 Copyright 2009, Access Specialties International, LLC All Rights Reserved

Contact Center CC-165 INSTALLATION & USER'S GUIDE

Contact Center CC-165 INSTALLATION & USER'S GUIDE Contact Center CC-165 INSTALLATION & USER'S GUIDE Table of Contents Introduction... 2 Specifications... 2 J4 Host Communications... 2 J5 and J12 (upper board)... 3 J6, J13, and 14 Input Connections...

More information

EQUIPMENT SPECIFICATIONS

EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access

More information

782 Electric Latch Retraction Controller Installation Instructions

782 Electric Latch Retraction Controller Installation Instructions 782 Electric Latch Retraction Controller Installation Instructions The 782 is designed to be used with UL Listed Yale 7000P series (electric latch retraction) or Corbin Russwin ED4000/ED5000 x M94 series

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

H Unit Input/Output Manual

H Unit Input/Output Manual H Unit Input/Output Manual 4 INPUTS 4 OUTPUTS RS485 Table of Contents Safety Rules...Inside Front Cover. Introduction...IFC 2. Communications...IFC 2.2 Baud Rate...IFC 2.3 Modbus Address... 2.4 Speed of

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

UNC500 HARDWARE MANUAL. new generation building security

UNC500 HARDWARE MANUAL. new generation building security UNC500 HARDWARE MANUAL new generation building security Copyright Notice Copyright 1995-2012 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant to an agreement

More information

ACM8 Series UL Listed Sub-Assembly Access Power Controllers Installation Guide

ACM8 Series UL Listed Sub-Assembly Access Power Controllers Installation Guide ACM8 Series UL Listed Sub-Assembly Access Power Controllers Installation Guide Models Include: ACM8 - Eight (8) Fuse Protected Outputs ACM8CB - Eight (8) PTC Protected Outputs SECURITY Rev. 042811 More

More information

Troubleshooting and Diagnostics

Troubleshooting and Diagnostics Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem

More information

CHAPTER 11: Flip Flops

CHAPTER 11: Flip Flops CHAPTER 11: Flip Flops In this chapter, you will be building the part of the circuit that controls the command sequencing. The required circuit must operate the counter and the memory chip. When the teach

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

Relays OBJECTIVES INTRODUCTION. Relays BASIC ELECTRICAL

Relays OBJECTIVES INTRODUCTION. Relays BASIC ELECTRICAL BASIC ELECTRICAL Relays Relays OBJECTIVES Describe the anatomy of a relay Describe the components of a common automotive SPDT relay Discuss the use of a SPDT relay in an electrical circuit INTRODUCTION

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

Allen-Bradley/Rockwell

Allen-Bradley/Rockwell MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:

More information

EMBEDDED ACCESS CONTROL Hardware Installation Guide

EMBEDDED ACCESS CONTROL Hardware Installation Guide EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

RCP-0006 Through RCP-0042 System Manual

RCP-0006 Through RCP-0042 System Manual Touch-Plate Lighting Controls RCP SERIES RCP Series System Manual RCP-0006 Through RCP-0042 System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323 Fax: 260-420-3651

More information

Integra32. Integrated Alarm Monitoring and Access Control HARDWARE MANUAL

Integra32. Integrated Alarm Monitoring and Access Control HARDWARE MANUAL Integra32 Integrated Alarm Monitoring and Access Control HARDWARE MANUAL C o p y r i g h t N o t i c e Copyright 1995-2010 by All rights reserved Worldwide. Printed in Canada. This publication has been

More information

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE. 0--00-0 (-0 ) R Low Energy Door Operators Wiring Instructions For 0, 0, 00, 0 REQUIREMENTS: 0 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

More information

USB Step and Direction Pulse Generator. User Manual

USB Step and Direction Pulse Generator. User Manual USB Step and Direction Pulse Generator User Manual 2012 Kellyware 1/15/2012 Table of Contents Table of Contents... 2 Parts List... 3 Key Features... 3 Introduction... 4 Installation... 5 Setup... 5 Wiring

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

2000e & 2000eM Keypad Installation & Programming Instructions

2000e & 2000eM Keypad Installation & Programming Instructions 2000e & 2000eM Keypad Installation & Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Parameter Voltage Requirements

More information

Latching AC Power Failure Detector for Sensatronics Temperature Monitors. Quick Start Guide

Latching AC Power Failure Detector for Sensatronics Temperature Monitors. Quick Start Guide Latching AC Power Failure Detector for Sensatronics Temperature Monitors Quick Start Guide Overview: This accessory for the TempElert software (standard and Spectrum versions) is designed to connect to

More information

SIGNALLING UNIT SACE PR010/K

SIGNALLING UNIT SACE PR010/K SIGNALLING UNIT Title titolo Manuale d uso Mod. Apparecchio Scala Lang. Lingua IT Scale 1/20 CONTENTS 1. GENERAL...3 1.1. INTRODUCTION...3 1.2. APPLICABLE SCENARIOS...3 2. TECHNICAL CHARACTERISTICS...4

More information

Ins-60005-GD-US. Master Controller Installation Guide

Ins-60005-GD-US. Master Controller Installation Guide Ins-60005-GD-US Master Controller Installation Guide Mounting This housing should be fixed to the surface with suitable fasteners; screws and wall plugs are provided for this in the fitting kit. Also provided

More information

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire) FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control

More information

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier Refer to the Lifestyle SA-2 & SA-3 Amplifier service manuals, part number 271720 for schematics, PCB layouts and parts lists. Preventative Repair Measures

More information

Saturday from 09:00-13:00 (GMT) Documentation on all Paxton products can be found on our website -

Saturday from 09:00-13:00 (GMT) Documentation on all Paxton products can be found on our website - 8/04/203 Ins-30075 Net2 nano control unit Paxton Technical Support 0273 80 support@paxton.co.uk Technical help is available: Monday - Friday from 07:00-9:00 (GMT) Saturday from 09:00-3:00 (GMT) Documentation

More information

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1. 1 Description The is a programmable 3 relay logic module that may be used for multiple applications, including simple timing, door mounted sensor inhibiting and advanced relay sequencing. The contains

More information

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc. Mini Effect Gizmo User s Manual RJM Music Technology, Inc. Mini Effect Gizmo User s Manual Version 1.3 September 26, 2013 RJM Music Technology, Inc. 2525 Pioneer Ave #1 Vista, CA 92081 E-mail: support@rjmmusic.com

More information

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue

More information

Digital Keypad with RFID Access Control User Manual

Digital Keypad with RFID Access Control User Manual Digital Keypad with RFID Access Control User Manual Contents: Name Quantity Remarks Digital Keypad 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing Self tapping screws 4 3.5*27mm,

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal O N DS160/DS161 Installation Guide High Performance Request-to-Exit Sensors 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for Request to Exit (REX) interior applications.

More information

DCM4826X Stepper Motor Drive

DCM4826X Stepper Motor Drive DCM4826X Stepper Motor Drive Manual www.haydonkerk.com All Rights Reserved 2 2012 1 Table of Contents Revision History... 3 Introduction... 4 Specifications... 5 Drawing... 6 Connections... 6 Motor Connection...

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION 28 13 00 SECURITY AND ACCESS CONTROL SYSTEM

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION 28 13 00 SECURITY AND ACCESS CONTROL SYSTEM DIVISION 28 ELECTRONIC SAFETY AND SECURITY PART 1 GENERAL 1.01 DESCRIPTION A. Division 28 Contractor shall extend a complete Matrix Systems Access Control System as shown on the Drawings and as specified

More information

Jazz PLC Powerhouse XL

Jazz PLC Powerhouse XL Jazz PLC Powerhouse XL Dual Drive Door Operating Instructions [Revision: December 10, 2012, 1600614-0, Rytec Corporation, 2012] TABLE OF CONTENTS PAGE INTRODUCTION.............................................1

More information

n/no co Fault Code No cooling detected by the controls

n/no co Fault Code No cooling detected by the controls n/no co Fault Code No cooling detected by the controls Models indicator displayed. ON GAS N6X/N8X ON LED flashes off 5 times, every 3 seconds AC AUTO N62X/N82X LP GAS N6X/N8X Display Audible Alarm Check

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

RGC12 Rain Gauge Converter

RGC12 Rain Gauge Converter RGC12 Rain Gauge Converter Introduction This converter is designed to allow our standard RH12H or RG12K rain gauge to be connected to a PLC, SCADA, BMS or other industrial control system without the need

More information

USB to RS-485 Optically Isolated Interface Handbook Revision 1.0

USB to RS-485 Optically Isolated Interface Handbook Revision 1.0 311-70 USB to RS-485 Optically Isolated Interface Handbook Revision 1.0 Contents Overview... 1 RS-485 Connections... 1 Shield... 1 Line Term... 2 Bias 1 & Bias 2... 2 RS-485 Cable... 2 USB Installation...

More information

Operating instructions I / DALI EASY II Version 1.0. General. Contents. General

Operating instructions I / DALI EASY II Version 1.0. General. Contents. General Operating instructions I / 2007 General Contents General Installation Appendix Safety information 2 Definition of terms 3 Application and function 4 Components 5 Wiring diagrams 6 Wiring diagrams 7 System

More information

WEB-TC Specifications

WEB-TC Specifications Specifications Document Revision 1.1, February, 2010 Copyright 2010, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design.

More information

CONTROL SWITCHER User s Manual (Preliminary)

CONTROL SWITCHER User s Manual (Preliminary) CONTROL SWITCHER User s Manual (Preliminary) www.voodoolab.com Copyright 2010 by Digital Music Corporation. This publication is protected by copyright and all rights are reserved. Voodoo Lab, Control Switcher,

More information

ASI-500 SCADA & Communications Software Manual

ASI-500 SCADA & Communications Software Manual ASI-500 SCADA & Communications Software Manual ASI-500 SCADA AND COMMUNICATIONS SOFTWARE MANUAL Crompton Instruments Freebournes Road Witham Essex CM8 3AH England An Invensys Company Tel: +44 (0) 1376

More information

D-TEK LM Vehicle Loop Detector - Operating Instructions

D-TEK LM Vehicle Loop Detector - Operating Instructions D-TEK LM Vehicle Loop Detector - Operating Instructions We at EMX have designed the new D-TEK vehicle loop detector with the following objectives in mind: 1. Compact package to allow easy installation

More information

OMNI 500 Filter Controller Manual Revision: 1.1, February 2011

OMNI 500 Filter Controller Manual Revision: 1.1, February 2011 OMNI 500 Filter Controller Manual Revision: 1.1, February 2011 Table of Contents Page I. Introduction 1 II. Using the Rotary Switches 2 III. Connection of Inputs, Outputs and Power 3 Wiring Schematics

More information

VARIO PROX CARD READER INSTALLATION MANUAL

VARIO PROX CARD READER INSTALLATION MANUAL VARIO PROX CARD READER INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION...2 1.1 Legend...3 1.2 Terminology...4 2.0 MOUNTING...5 3.0 WIEGAND CONNECTION...6 4.0 AUX BUTTON INPUT...7 5.0 INSTALLER PROGRAMMING...8

More information

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete

More information

Omega.com TM. RELAY-URM SERIES Universal Relay Module

Omega.com TM.    RELAY-URM SERIES Universal Relay Module Omega.com TM http://www.omega.com e-mail: info@omega.com RELAY-URM SERIES Universal Relay Module SPECIFICATIONS... 2 DESCRIPTION... 3 POWER CONNECTION... 3 INPUT CONNECTIONS Relays 1-4... 4 Figure 2:

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

AE8-1328 R5 March 2011. Copeland Digital Compressor Controller AE8-1328 R5. Specifications

AE8-1328 R5 March 2011. Copeland Digital Compressor Controller AE8-1328 R5. Specifications AE8-1328 R5 March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the Copeland

More information

Remote Control Cut Off Switch NEFA20 Plus F1

Remote Control Cut Off Switch NEFA20 Plus F1 Remote Control Cut Off Switch NEFA20 Plus F1 Installation Guide Please read this entire guide before beginning the installation! Supplied Parts Antenna NEFA20 F1 Plus Cutoff Switch Protective Covers DIN

More information

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation. This quick start guide provides, basic installation information, drawings, first time power-on instructions, and short descriptions of key terms and concepts for installing the EntraGuard Platinum Telephone

More information

NetAXS-123 Startup Guide, Document NetAXS-123. Startup Guide Honeywell, Inc. 1

NetAXS-123 Startup Guide, Document NetAXS-123. Startup Guide Honeywell, Inc.  1 NetAXS-123 Startup Guide 2010 Honeywell, Inc. www.honeywell.com 1 PoE PWR +12VDC Configuration External Power Supply Configuration RUN RDR STS NO/NC Dry C Return NO/NC Dry C Return Reader B** (Optional)

More information

PLC Line. USER S MANUAL Catalog No Rev. E

PLC Line. USER S MANUAL Catalog No Rev. E PLC Line USER S MANUAL Catalog No. 100125 Rev. E May 2015 Copyright 2015 Intelitek Inc. PLC Line User s Manual Catalog No. 100125 Rev. E May 2015 Every effort has been made to make this technical note

More information

FIREFLY II RELEASE DEVICES MADE IN THE U.S.A. FIREFLY II/IIB INSTALLATION MANUAL

FIREFLY II RELEASE DEVICES MADE IN THE U.S.A. FIREFLY II/IIB INSTALLATION MANUAL FIREFLY II RELEASE DEVICES MADE IN THE U.S.A. FIREFLY II/IIB INSTALLATION MANUAL GENERAL DESCRIPTION: U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 S/N The The Cookson Company FIREFLY II" Series Time

More information

CENTRAL BATTERY UNIT FOR EMERGENCY LIGHTING. Installation and maintenance instructions TKT65XXB

CENTRAL BATTERY UNIT FOR EMERGENCY LIGHTING. Installation and maintenance instructions TKT65XXB 1 VOT6506E CENTRAL BATTERY UNIT FOR EMERGENCY LIGHTING Installation and maintenance instructions TKT65XXB KEEP IN A SAFE PLACE FOR LATER USE 2 TKT65XXB product description REV.4; 20.07.2009 JAK Table of

More information

Controller 5000GL Controller 5000GL provides flexible system architecture with options of GBUS and LOCAL BUS communications to field devices, to meet a wide range of site requirements. GGBUS L LOCAL BUS

More information

PRT3 Printer Module: ASCII Protocol Programming Instructions

PRT3 Printer Module: ASCII Protocol Programming Instructions PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

INDEX 1. INTRODUCTION 2. FEATURES AND FUNCTIONS 3. INSTALLATION... 7

INDEX 1. INTRODUCTION 2. FEATURES AND FUNCTIONS 3. INSTALLATION... 7 INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION... 7 3.1 Falcon GSM Wiring...

More information

Workshop 7 PC Software - Tracker

Workshop 7 PC Software - Tracker Workshop 7 PC Software - Tracker Goal: You will startup and perform advanced setup functions using Tracker PC software. You will also setup equations to control MP503 binary outputs. The Binary Output

More information

I/O Applications CHAPTER. Setting Up I/O Devices

I/O Applications CHAPTER. Setting Up I/O Devices CHAPTER 2 I/O Applications This chapter discusses how you can set up and control the I/O devices connected to GV-System. I/O applications include these features: Configure I/O devices Move PTZ to a preset

More information

APR-PRT3 Printer Module: C-Bus Programming Instructions

APR-PRT3 Printer Module: C-Bus Programming Instructions APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us

More information

PIC-113 USB+RS232 I/O Controller

PIC-113 USB+RS232 I/O Controller PIC-113 USB+RS232 I/O Controller User Manual Product Code: PIC-113 Version: ver 1.0 Last Updated: 25-Jul-2012 PIC-113 USB+RS232 I/O Controller version 1.0 Page 1 of 17 Content Description...3 Features...3

More information

COMPALARM C2C ALARM SYSTEM

COMPALARM C2C ALARM SYSTEM INSTRUCTION MANUAL IM670-U v0.1 COMPALARM C2C ALARM SYSTEM GENERAL Compact alarm system, with a basic module of 12 signals Multiple modules coupling possibility Easy printing of the alarm points description

More information

Mini Amp Gizmo. User s Manual. RJM Music Technology, Inc.

Mini Amp Gizmo. User s Manual. RJM Music Technology, Inc. Mini Amp Gizmo User s Manual RJM Music Technology, Inc. Mini Amp Gizmo User s Manual Version 1.1 March 15, 2012 RJM Music Technology, Inc. 2525 Pioneer Ave #1 Vista, CA 92081 E-mail: support@rjmmusic.com

More information

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805) SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca. 93041 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck The

More information

DC-8706K Auto Dial Alarm System

DC-8706K Auto Dial Alarm System DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The

More information

Bluetooth HC-06 with serial port module Easy guide

Bluetooth HC-06 with serial port module Easy guide 1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550

More information

Electronic Refrigerator Diagnostics

Electronic Refrigerator Diagnostics Electronic Refrigerator Diagnostics IMPORTANT SAFETY NOTICE The information in this presentation is intended for use by individuals possessing adequate backgrounds of electrical, electronic, & mechanical

More information

Communication interface UT-4DR

Communication interface UT-4DR Roger Access Control System Communication interface UT-4DR Firmware version : 1.0.0.58 Document version: Rev. A Contents 1. Description and specification... 3 1.1 Characteristics... 3 1.2. Using the interface

More information

APOLLO Gate Operators, Inc. 835/836 Gate Control Board Firmware Version 31 and up

APOLLO Gate Operators, Inc. 835/836 Gate Control Board Firmware Version 31 and up APOLLO Gate Operators, Inc. 835/836 Gate Control Board Firmware Version 31 and up Rev F 07/15/2005 PROGRAMMING INSTRUCTIONS Once the operator is installed or if the control board is replaced, you will

More information

Single Channel Loop Detector

Single Channel Loop Detector Single Channel Loop Detector Model - LD100 Series The LD100 is a single channel inductive loop detector designed for parking and access control applications. The detector is connected to an inductive loop

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

Version 2.1

Version 2.1 IPC-1H Version 2.1 Thank you for purchasing our COMM Integrated Control Switches! COMM Integrated Control Switches (IPC Series) - Designed to control your Audiovisual Equipment in the most simplified ways

More information

ImproX IXP20 Controller INSTALLATION MANUAL

ImproX IXP20 Controller INSTALLATION MANUAL MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

Data Sheet SIMATIC S7-200 CPU 226 DC/DC/DC and CPU 226 AC/DC/Relay

Data Sheet SIMATIC S7-200 CPU 226 DC/DC/DC and CPU 226 AC/DC/Relay SIMATIC S7-200 and Table 1 Specifications for and Physical Size Dimensions (W x H x D) Weight Power loss (dissipation) CPU Features On-board digital inputs On-board digital outputs High speed counters

More information

S7-200 Micro PLCs. The model description indicates the type of CPU, the power supply, the type of input, and the type of output.

S7-200 Micro PLCs. The model description indicates the type of CPU, the power supply, the type of input, and the type of output. S7-200 Micro PLCs The S7-200 Micro PLC is the smallest member of the SIMATIC S7 family of programmable controllers. The central processing unit (CPU) is internal to the PLC. Inputs and outputs (I/O) are

More information

500r+ Installation and User Guide

500r+ Installation and User Guide 500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

ManagerTM. Installation and Programming MagStripe Readers

ManagerTM. Installation and Programming MagStripe Readers ManagerTM Installation and Programming MagStripe Readers WSE TECHNICAL SUPPORT SERVICE GROUP, 1998, P/N 6600038 47102 Mission Falls Court Fremont, CA 94539-7818 an ISO 9001 certified company PHONE (510)

More information

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP

More information

Power Switch-8. Master. Slave. User's Guide. Power Management

Power Switch-8. Master. Slave. User's Guide. Power Management Power Switch-8 Power Management Master Slave User's Guide V.02/2004 Power Switch-8 Power Switch-8 is a couple of power control units made of a Master named Power Switch Master and a slave named Power Switch

More information

SPECTRA 1727 V1.10 COMPLETE INSTALLATION MANUAL. Reference, Installation and Programming

SPECTRA 1727 V1.10 COMPLETE INSTALLATION MANUAL. Reference, Installation and Programming SPECTRA 1727 V1.10 1727 COMPLETE INSTALLATION MANUAL Reference, Installation and Programming TABLE OF CONTENTS INTRODUCTION... 3 1 1.1 Features... 3 1.2 Specifications... 3 1.2.1 Spectra 1727 Control

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

D1 Swing Gate Control Board Manual. Warning: Insure you have sealed all means of entry to the control box by insects and water.

D1 Swing Gate Control Board Manual. Warning: Insure you have sealed all means of entry to the control box by insects and water. D1 Swing Gate Control Board Manual Imported by www.gateopener.co.nz PO Box 9215 Tauranga New Zealand sales@gateopener.co.nz Warning: Insure you have sealed all means of entry to the control box by insects

More information

GA-200 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-200 Gas Analyzer

GA-200 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-200 Gas Analyzer Technical Note Overview The uses sensors to measure and display the concentrations of oxygen and carbon dioxide in a sample as the percentage of a gas in the sample by volume. This method of expressing

More information

TS510 & TS500. Installation & User Guide. Compatible Equipment

TS510 & TS500. Installation & User Guide. Compatible Equipment Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction

More information

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.:

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.: Documento: M-010.1-MGAS-ENG Edizione: 01/1997 Rev.: A.1 a Division of Pittway Corporation FRONT PANEL & VISUAL INDICATIONS GENERAL TROUBLE GENERAL PROGRAMMING IN PROGRESS ENABLE/ALARM/TROUBLE (ZONE 1 ALARM

More information

9448 Installation and User Guide

9448 Installation and User Guide 9448 Installation and User Guide Compatible Equipment 9040 Internal Sounder 660 Speech communicator 496327 Issue 1 1 of 6 9448 INTRODUCTION The 9448 is a 3 zone control panel with separate Entry/Exit and

More information

BC-8000 Field Calibration Procedure 55 AMP

BC-8000 Field Calibration Procedure 55 AMP BC-8000 Field Calibration Procedure 55 AMP CF1_FIELDCAL_BC8000 Revised 9/8/2012 Charger section can be used on a BC-9000 Version 1.00 INTRODUCTION: The BC-8000 Battery Capacity Analyzer and Charger will

More information

Inductive Proximity Sensors

Inductive Proximity Sensors M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12

More information

ATS1190 Smart Card Reader. Programming Manual. 1) Format: 16 pages A4 Bookshape (stapled). Formaat: 16 pagina's A4 Boekvorm (geniet).

ATS1190 Smart Card Reader. Programming Manual. 1) Format: 16 pages A4 Bookshape (stapled). Formaat: 16 pagina's A4 Boekvorm (geniet). ATS1190 Smart Card Reader Programming Manual Version 2.0 1) Format: 16 pages A4 Bookshape (stapled). Formaat: 16 pagina's A4 Boekvorm (geniet). 2) Text may differ from original and is for reference only.

More information

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Ethernet. Customer Provided Equipment Configuring the Ethernet port. Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.

More information