1 RI-120 READER INTERFACE & Contact Expansion Module CEM-133 INSTALLATION & USER'S GUIDE Page 1 Copyright 2009, Access Specialties International, LLC All Rights Reserved

2 Table of contents Introduction pg 3 Specifications pg 3 Communications to Host (J4) pg 4 Installing a reader (J5) pg 4 Monitor Points (J6) pg 5 Output Point (J7) pg 6 Power Hook-up (J8) pg 6 Switch 1 (Degraded mode relay times) pg 7 Degraded Mode Explanation pg 7 Switch 2 (Degraded mode system codes) pg 8 System Code Reference (Table 8.1) pg 8 Contact Expansion Module (CEM 133) pg 9 Troubleshooting Techniques pg 11 Resetting the RI pg 12 General System Installation Diagram Figure 3.1 RI-120 Schematic Figure 3.2 Options for the Door Open Detect Monitor point Figure 5.1, 5.2 Page 2 Copyright 2009, Access Specialties International, LLC All Rights Reserved

3 INTRODUCTION The RI-120 is a Reader Interface Board that was designed to work with the IC-1600 Intelligent Controller and the Access Gold or ASI 200 software programs. It is capable of working with any wiegand output card-reader. The RI-120 transfers the data from the card reader up to the IC Four Monitoring points on the RI-120 also send signals up to the IC Two output relays on the RI-120 are provided for door access control. The CEM 133 Contact Expansion Module may be used with the RI-120 to expand the RI- 120 monitor and output points. Note: This document is valid only for RI-120 boards with firmware version 4.0 or higher. SPECIFICATIONS Card Technology: Barium Ferrite, Wiegand, Mag Stripe, Proximity Readers Momentary Door Unlocking: Switch selectable 2 to 16 seconds * Alarm Shunting: Switch selectable 6 to 48 seconds * Degraded Mode: Switch selectable system code 4 Monitored Input Points DOD, Exit Pushbutton,Tamper, User Definable 2 Controlled Output Points Go Relay & Shunt Relay Output Door Relay Contact Rating: Power Requirements: Operating Temperature: 120vac or 3A 60Hz at 1A, or 12 volts DC at 1 A -40 C to 75+ C *(RI-120 Unlocking and shunting time is 1 to 255 seconds when used with the ACCESS GOLD or ASI 2000 security systems.) Page 3 Copyright 2009, Access Specialties International, LLC All Rights Reserved

4 J4 HOST COMMUNICATIONS J4 provides the connections for communications to the host IC1600 or a CE Removable terminal blocks are provided for easy installation. The RI-120 requires a 4-wire connection to the host. The cable should be 22 gauge, shielded cable, consisting of 2 twisted pair, and all shields earth grounded at one end. The maximum distance is 2 miles from the IC A Channel expander (A channel expander multiplexes one channel on the IC-1600 into 16 ports) can extend that distance another 2 miles. Please note that the greater the distance, the greater the delay in transfer of data between the RI-120 and the IC Host ( a channel J4 - RI-120 or port ) Data + Pin #1 Data - Pin #2 Enable + Pin #3 Enable - Pin #4 J5 INSTALLING A READER The RI-120 provides 6 wire connections for a reader. The cable length from the reader to the RI-120 should not exceed 500 feet. The cable should be 22 gauge, shielded cable, consisting of 3 twisted pair, and all shields earth grounded at one end. The standard RI-120 will read 26 or 27 bit card formats (customized firmware for the RI-120 supports additional card formats). J5 provides the following connections for a reader: Compatible Reader J5 - RI-120 5VDC Pin #1 20VDC Pin #2 Ground Pin #3 LED Control Pin #4 Data 0 Pin #5 Data 1 Pin #6 Page 4 Copyright 2009, Access Specialties International, LLC All Rights Reserved

5 J6 INPUT CONNECTIONS Three dedicated software-defined inputs, along with one user definable input are available. The software defined monitoring points are for the EXIT push-button, DOOR OPEN DETECT monitor, and TAMPER detect (Note: a grounding connector is provided). All inputs have an LED indicator, which will emit light when the input contacts are closed. Label J6 - RI-120 Input 0 Pin #1 Door Open Detect/Forced Entry Detect * Input 1 Pin #2 Exit Push-button Input 2 Pin #3 Tamper Detect Input 3 Pin #4 User Definable Ground Pin #5 Ground Pin #6 All monitor points can be tied to alarms and conditional responses in the host access control software. The Door Open Detect input is explained in detail on figure 5.1 and 5.2 at the end of this guide. When the Exit Push-button s circuit is completed with the Ground, both the Go and the Shunt relay will fire. As long as the circuit is completed, the relays will stay energized. After the circuit is opened, the relays will stay energized for their respective times. Tamper detected message is reported when the RI-120 senses that the input went from a closed state to an open state. The User Definable monitor point can be used for anything from motion sensors, smoke detectors and other items. All User definable monitor points must be defined in the Monitor Points tab of the RI-120 device definition if they are to be used. If you issue a Go-Offline command to the RI-120, the RI-120 would not report any activity from all user-definable points. This includes the 1 point that comes with the RI-120 (input 3) and the 12 additional points on the CEM-133. To allow the activity to be reported again, issue a Go-Online command to the RI-120. Commanding Reader Interfaces to Go-Offline has nothing to do with communications, Degraded mode, or the software defined monitor points. It only tells the Reader Interface to ignore the activity on the User Defined inputs. This can be helpful when these points are tied to alarms and conditional responses. The RI-120 is capable of shunting the user-definable monitor points. If you choose No Shunt for the monitor point, then all activity for the monitor point is reported immediately. If you select the Open option and designate a shunt time, the system will wait for the duration of the shunt time to report it as an Open condition. This would be used when the monitor point is normally in a closed state. If the monitor point is normally open, you could select the Closed option to shunt. The amount of time that you specify for the condition to shunt is how long the system has to wait before reporting the Closed state to the host software. Page 5 Copyright 2009, Access Specialties International, LLC All Rights Reserved

6 J7 OUTPUT CONNECTIONS There are 2 dedicated relay outputs available: 1 GO relay and 1 SHUNT relay. Three additional user-definable outputs are available by adding a CEM-133. All output relays are rated at 28 VDC or 120VAC, with both voltages rated at 3A. Each output has an LED indicator that emits light when the relay is energized. When D10 emits light, this indicates that the Go relay is energized. When D11 emits light that indicates that the Shunt relay is energized. The Go time symbolizes the amount of time the user has to open the door. The Shunt time symbolizes the amount of time the user has to close the door. If the door is not closed within the shunt time, Door Held Open is reported in Monitor Activity of Access Gold or in Transaction Monitor of ASI Function J7 RI-120 Output 0 Common Pin #1 * Output 0 Normally Open Pin #2 Output 0 Normally Closed Pin #3 Output 1 Common Pin #4 * Output 1 Normally Open Pin #5 Output 1 Normally Closed Pin #6 * Note: Output 0 is the GO RELAY and Output 1 is the SHUNT RELAY. J8 POWER HOOK-UP J5 for the card reader should be connected before powering up the RI-120. J4 and J6 may be connected or disconnected while the RI-120 is powered up. Power J8 RI vac/12VDC+ Pin #1 12vac/12VDC- Pin #2 Ground Pin #3 Not Used Pin #4 Page 6 Copyright 2009, Access Specialties International, LLC All Rights Reserved

7 Switch 1 S1 controls the Go and Shunt Relays times when the Reader Interface is in Degraded Mode. Please note that if the reader has communications with the host, the Go and Shunt times can be set between 1 and 255 seconds. These times are set in Device Definition of the card reader, under Access Gold. For ASI 2000, they are set in the Device Center module. Pin 9 of S1 informs the RI-120 if there is a CEM-133 connected to it or not. RI-120 DIP Switch S1 Codes For the Go and Shunt times in Degraded Mode Go Time Position 1 Position 2 Position 3 2 Seconds Off Off Off 4 Off Off On 6 Off On Off 8 Off On On 10 On Off Off 12 On Off On 14 On On Off 16 On On On Shunt Time Position 4 Position 5 Position 6 6 Seconds Off Off Off 12 Off Off On 18 Off On Off 24 Off On On 30 On Off Off 36 On Off On 42 On On Off 48 On On On Switch 1 also controls the speed the RI-120 will attempt to communicate with the host, if the host panel supports multi-speed communications. Comm Speed Position 7 Position Baud Off Off 1200 Off On 2400 On Off Switch 2 S2 controls how the reader reacts in Degraded Mode If the RI-120 looses communication with the host IC-1600 (or CE-1600) for over fifteen seconds, the RI-120 goes into what is called Degraded Mode. In Degraded Mode the RI-120 compares the system code encoded on the card with the system code configured by setting Switch 2. If the system codes match, the RI-120 will energize the Go and Shunt Relays. Table 8.1 provides the appropriate settings for system codes 0 to 255 Page 7 Copyright 2009, Access Specialties International, LLC All Rights Reserved

8 Table 8.1 Legend: 0 = OFF 1 = ON System Code Settings - S2 SYS SYS SYS SYS Page 8 Copyright 2009, Access Specialties International, LLC All Rights Reserved

9 CEM-133 CONTACT EXPANSION MODULE OPTION (RI S1) To add 12 user-definable monitoring points and 3 controlled output relays, the CEM-133 must be attached on J1 of the RI-120. In order to activate the CEM- 133, position 9 on Switch 1 of the RI-120 board must be turned ON. When this position is turned OFF, the CEM-133 is not activated. INPUT CONNECTIONS (CEM J13 & J14) The CEM provides 12 additional input points to the RI-120 Reader Interface. An open contact will have VDC across it. A closed point will have approximately 10 ma of current. All of the input points for J14 are electrically common to ground. For more information on the usage of these inputs, see the user-definable section under the RI-120 inputs (J6). Function J13 - Pin# J14 - Pin# LED Input 4 Pin 1 Pin 1 D7 (NOTE: Inputs 0-3 Input 5 Pin 2 Pin 2 D8 are provided by the Input 6 Pin 3 Pin 3 D9 RI-120.) Input 7 Pin 4 Pin 4 D10 Input 8 Pin 5 Pin 5 D12 Input 9 Pin 6 Pin 6 D13 Input 10 Pin 7 Pin 7 D14 Input 11 Pin 8 Pin 8 D15 Input 12 Pin 9 Pin 9 D16 Input 13 Pin 10 Pin 10 D17 Input 14 Pin 11 Pin 11 D18 Input 15 Pin 12 Pin 12 D19 OUTPUT CONNECTIONS (J15) The CEM-133 provides three additional relay outputs. The output points are specified for 28VDC or 120VAC, with both voltages at 3A. Function J15 - Pin # LED Output 2 Common Pin 1 D4 (NOTE: Output Output 2 Normally Open Pin 2 points 0-1 are Output 2 Normally Closed Pin 3 provided by the Output 3 Common Pin 4 D5 RI-120.) Output 3 Normally Open Pin 5 Output 3 Normally Closed Pin 6 Output 4 Common Pin 7 D6 Output 4 Normally Open Pin 8 Output 4 Normally Closed Pin 9 Page 9 Copyright 2009, Access Specialties International, LLC All Rights Reserved

10 CEM-133 WIRING DIAGRAM & LEGEND Output 2 C. Output 2 N.O. Output 2 N.C. Output 3 C. Output 3 N.O. Output 3 N.C. Output 4 C. Output 4 N.O. Output 4 N.C J15 J12 (Not used) Note: C = Common NO = Normally Open NC = Normally Closed J14 Input 4 Input 5 Input 6 Input 7 Input 8 Input 9 Input 10 Input 11 Input 12 Input 13 Input 14 Input J13 Page 10 Copyright 2009, Access Specialties International, LLC All Rights Reserved

11 TROUBLESHOOTING TECHNIQUES Tech Tip 1 Determining whether the RI-120 is getting data from the card reader 1. Present the card to the card reader. 2. While presenting the card, watch LED D5 on the RI If LED D5 flashes once as the card is presented, that means that the card reader is successfully sending up the data to RI-120. Tech Tip 2 Visually checking if there is communications from the RI-120 to the IC- 1600/CE Access Gold /panelcom or ASI Launch/Panel Manager need to be running. 2. The device number or device name of the Reader Interface must be known. 3. Look up the Device number in Device Definitions. Find out what channel or port the RI-120 is connected to on the IC-1600 or CE Edit the IC-1600 and make sure that the channel is checked so the channel is ON. 5. Look at the channel (or port for a CE-1600) and verify that the Led is flashing (the more channels that are ON, the slower the LEDs will flash). Tech Tip 3 Checking the communications from the Software 1. Access Gold /panelcom or ASI Launch/Panel Manager need to be running. 2. Click on the Monitor activity button, in Access Gold, to watch the real time transactions. For ASI 2000, click on the Transaction Monitor module. 3. Transactions from other devices must be reporting. If nothing is being reported in the Monitor activity screen or Transaction Monitor, there may be a problem with panelcom or Panel Manager respectively. 4. Send a signal up to the RI-120. Either change the state of a monitor point or present a card to the reader. 5. In the system activity screen, the signal that was just sent up from the RI-120 should be reported. If nothing is reported then there is no communications to the host. Tech Tip 4 Finding out the encoded # of a card The Same steps in Tech Tip 3 can identify the encoded #. This procedure would be necessary if the number on the outside of the card (embossed #) is different from the encoded number, and there is not a reference sheet that tells the tech these numbers. Tech Tip 5 Finding out the Device # of a Reader Interface 1. The Same steps in Tech Tip 3 can be taken to identify the device # of an RI-120 (or any other unit). When sending the signals up from the RI-120 to the IC-1600 the appropriate messages ( Access Granted, Tamper Detected etc ) should be reported with a device # or device name. 2. You can look up the device # or device name under System Devices or Device Center. The Device Definitions provides important information on the RI-120. For example, the panel #, channel #, port #, Go and Shunt times etc 3. If there is not a device # assigned to the RI-120, the message Undefined Reader will report along with the channel and port # s. Page 11 Copyright 2009, Access Specialties International, LLC All Rights Reserved

12 Tech Tip 6 Replacing a bad Comm. 20 board. 1. Many times when communications is not functioning between the IC-1600 and the Reader Interface, the comm20 board has gone bad. 2. The comm20 board is the small circuit board that is upside down in reference to the RI To replace it, power down the RI The comm20 board has two J connections. J1 and J2. 5. The process for installing the comm20 board onto the RI-120 board is to connect the low number from the comm20 board to the low number on the RI-120. This process is the same for all of Access Specialties communications daughter boards and devices. 6. Power may now be reapplied. Resetting the Reader Interface Boards 1. Power down the Reader Interface board. 2. Turn off all of the dip-switches on both S1 and S2. 3. Turn Pin 7 & 8 on SW1 to the ON position. 4. Power up the Reader Interface Board. 5. Wait 5 seconds. 6. Power down the Reader Interface. 7. Put original settings back in the switches (go & shunt times, system code, and communications speed) and power up the RI-120 board. 8. The reader interface has now been reset. This procedure can be tried whenever a Reader Interface is not sending up the card Data to the IC-1600 This procedure is also the same process for all other Reader Interfaces (RI-110 & RI- 130) This procedure causes the Go relay to chatter during this process. This chattering verifies that the RI-120 is resetting itself. This procedure will reset the operating mode to whatever is set on SW1 pins 1, 2, and 3 as follows: New Mode Position 1 Position 2 Position 3 Card Only Off Off Off Card plus Pin Off Off On Card or Pin Off On Off This procedure will reset the programmed Go and Shunt times. To restore them you will have to edit the device in Access Gold or ASI-2000 and save it. Page 12 Copyright 2009, Access Specialties International, LLC All Rights Reserved

Contact Center CC-165 INSTALLATION & USER'S GUIDE

Contact Center CC-165 INSTALLATION & USER'S GUIDE Contact Center CC-165 INSTALLATION & USER'S GUIDE Table of Contents Introduction... 2 Specifications... 2 J4 Host Communications... 2 J5 and J12 (upper board)... 3 J6, J13, and 14 Input Connections...

More information

EQUIPMENT SPECIFICATIONS

EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

Troubleshooting and Diagnostics

Troubleshooting and Diagnostics Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem

More information

UNC500 HARDWARE MANUAL. new generation building security

UNC500 HARDWARE MANUAL. new generation building security UNC500 HARDWARE MANUAL new generation building security Copyright Notice Copyright 1995-2012 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant to an agreement

More information

CHAPTER 11: Flip Flops

CHAPTER 11: Flip Flops CHAPTER 11: Flip Flops In this chapter, you will be building the part of the circuit that controls the command sequencing. The required circuit must operate the counter and the memory chip. When the teach

More information

Integra32. Integrated Alarm Monitoring and Access Control HARDWARE MANUAL

Integra32. Integrated Alarm Monitoring and Access Control HARDWARE MANUAL Integra32 Integrated Alarm Monitoring and Access Control HARDWARE MANUAL C o p y r i g h t N o t i c e Copyright 1995-2010 by All rights reserved Worldwide. Printed in Canada. This publication has been

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

EMBEDDED ACCESS CONTROL Hardware Installation Guide

EMBEDDED ACCESS CONTROL Hardware Installation Guide EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel

More information

Allen-Bradley/Rockwell

Allen-Bradley/Rockwell MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire) FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control

More information

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc. Mini Effect Gizmo User s Manual RJM Music Technology, Inc. Mini Effect Gizmo User s Manual Version 1.3 September 26, 2013 RJM Music Technology, Inc. 2525 Pioneer Ave #1 Vista, CA 92081 E-mail: support@rjmmusic.com

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

DC-8706K Auto Dial Alarm System

DC-8706K Auto Dial Alarm System DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier Refer to the Lifestyle SA-2 & SA-3 Amplifier service manuals, part number 271720 for schematics, PCB layouts and parts lists. Preventative Repair Measures

More information

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal O N DS160/DS161 Installation Guide High Performance Request-to-Exit Sensors 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for Request to Exit (REX) interior applications.

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The

More information

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation. This quick start guide provides, basic installation information, drawings, first time power-on instructions, and short descriptions of key terms and concepts for installing the EntraGuard Platinum Telephone

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

Workshop 7 PC Software - Tracker

Workshop 7 PC Software - Tracker Workshop 7 PC Software - Tracker Goal: You will startup and perform advanced setup functions using Tracker PC software. You will also setup equations to control MP503 binary outputs. The Binary Output

More information

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP

More information

PRT3 Printer Module: ASCII Protocol Programming Instructions

PRT3 Printer Module: ASCII Protocol Programming Instructions PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send

More information

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION 28 13 00 SECURITY AND ACCESS CONTROL SYSTEM

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION 28 13 00 SECURITY AND ACCESS CONTROL SYSTEM DIVISION 28 ELECTRONIC SAFETY AND SECURITY PART 1 GENERAL 1.01 DESCRIPTION A. Division 28 Contractor shall extend a complete Matrix Systems Access Control System as shown on the Drawings and as specified

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

VARIO PROX CARD READER INSTALLATION MANUAL

VARIO PROX CARD READER INSTALLATION MANUAL VARIO PROX CARD READER INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION...2 1.1 Legend...3 1.2 Terminology...4 2.0 MOUNTING...5 3.0 WIEGAND CONNECTION...6 4.0 AUX BUTTON INPUT...7 5.0 INSTALLER PROGRAMMING...8

More information

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete

More information

Single Channel Loop Detector

Single Channel Loop Detector Single Channel Loop Detector Model - LD100 Series The LD100 is a single channel inductive loop detector designed for parking and access control applications. The detector is connected to an inductive loop

More information

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue

More information

CONTROL SWITCHER User s Manual (Preliminary)

CONTROL SWITCHER User s Manual (Preliminary) CONTROL SWITCHER User s Manual (Preliminary) www.voodoolab.com Copyright 2010 by Digital Music Corporation. This publication is protected by copyright and all rights are reserved. Voodoo Lab, Control Switcher,

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

500r+ Installation and User Guide

500r+ Installation and User Guide 500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and

More information

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.:

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.: Documento: M-010.1-MGAS-ENG Edizione: 01/1997 Rev.: A.1 a Division of Pittway Corporation FRONT PANEL & VISUAL INDICATIONS GENERAL TROUBLE GENERAL PROGRAMMING IN PROGRESS ENABLE/ALARM/TROUBLE (ZONE 1 ALARM

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

APR-PRT3 Printer Module: C-Bus Programming Instructions

APR-PRT3 Printer Module: C-Bus Programming Instructions APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

Inductive Proximity Sensors

Inductive Proximity Sensors M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Troubleshooting and Diagnostics

Troubleshooting and Diagnostics Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem

More information

Controller 5000GL Controller 5000GL provides flexible system architecture with options of GBUS and LOCAL BUS communications to field devices, to meet a wide range of site requirements. GGBUS L LOCAL BUS

More information

9448 Installation and User Guide

9448 Installation and User Guide 9448 Installation and User Guide Compatible Equipment 9040 Internal Sounder 660 Speech communicator 496327 Issue 1 1 of 6 9448 INTRODUCTION The 9448 is a 3 zone control panel with separate Entry/Exit and

More information

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Ethernet. Customer Provided Equipment Configuring the Ethernet port. Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.

More information

EDI Distributor Control Interface Wiring and Setup Instructions

EDI Distributor Control Interface Wiring and Setup Instructions Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls

More information

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power) MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

Mini Amp Gizmo. User s Manual. RJM Music Technology, Inc.

Mini Amp Gizmo. User s Manual. RJM Music Technology, Inc. Mini Amp Gizmo User s Manual RJM Music Technology, Inc. Mini Amp Gizmo User s Manual Version 1.1 March 15, 2012 RJM Music Technology, Inc. 2525 Pioneer Ave #1 Vista, CA 92081 E-mail: support@rjmmusic.com

More information

SMART SENSOR COLLECTION

SMART SENSOR COLLECTION TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8

More information

TS510 & TS500. Installation & User Guide. Compatible Equipment

TS510 & TS500. Installation & User Guide. Compatible Equipment Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction

More information

Business/Home GSM Alarm System. Installation and User Manual

Business/Home GSM Alarm System. Installation and User Manual Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene

More information

Current Loop Application Note 1495

Current Loop Application Note 1495 Current Loop Application Note Document No. CLAN1495 International Headquarter B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax

More information

Termination Resistors:

Termination Resistors: DeviceNet will not function correctly if design rules are not followed. Even a Network previously thought to be functioning correctly may begin to exhibit abnormal or anomalous operation due to incorrect

More information

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) February 2015 February 2015 Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) This document describes how to connect an electricity meter to a SolarEdge device (inverters,

More information

FAQs. XAP Frequently Asked Questions. Software/Configuration

FAQs. XAP Frequently Asked Questions. Software/Configuration XAP Frequently Asked Questions ~ Software/Configuration ~ Echo Cancellation ~ Audio Performance ~ Expansion Bus ~ Firmware ~ Installation ~ Presets ~ Telephone Hybrid Software/Configuration What is the

More information

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134 AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN SP1134 Power and productivity for a better world TM AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN NOTICE This document contains information

More information

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers. How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers. OMEGALOG Help Page 2 Connecting Your Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data Page 11 Downloading

More information

EVAL-UFDC-1/UFDC-1M-16

EVAL-UFDC-1/UFDC-1M-16 Evaluation Board for Universal Frequency-to- Digital Converters UFDC-1 and UFDC-1M-16 EVAL-UFDC-1/UFDC-1M-16 FEATURES Full-Featured Evaluation Board for the Universal Frequency-to-Digital Converters UFDC-1

More information

Fire Fighter Phone System Installation Instructions

Fire Fighter Phone System Installation Instructions Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the Fire Fighter s Phone on a 4100U or a 4100ES Fire Alarm Control Panel (FACP).

More information

Paragon Explorer Lite Communication Software

Paragon Explorer Lite Communication Software CU-111 APRIL 11, 2013 Paragon Explorer Lite Communication Software For Fireye Paragon Scanners using Windows XP DESCRIPTION Paragon Explorer Lite, is the basic PC based configuration tool for Paragon model

More information

Poseidon2 3268 MANUAL

Poseidon2 3268 MANUAL Poseidon2 3268 MANUAL Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested and is supplied

More information

Pop-up Surveillance Camera On Your TV

Pop-up Surveillance Camera On Your TV Pop-up Surveillance Camera On Your TV Would you like to automatically see who s at your front door, even before they ring the doorbell? It s easy to do! Just follow the simple steps described below. CAMERA

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

Access Control Unit User s Guide

Access Control Unit User s Guide NetAXS Access Control Unit User s Guide The configurations described in this document have not been reviewed by Underwriters Laboratories Inc. June 2007 2007 Honeywell. All rights reserved. 800-00233,

More information

IAdea GPIO Extender Application Note

IAdea GPIO Extender Application Note IAdea GPIO Extender Application Note Contents Introduction... 1 What is GPIO Extender?... 1 Digital Input and Output Applications... 2 Wiring Instructions... 4 Software Instructions... 7 Setup Example

More information

Bluetooth HC-06 with serial port module Easy guide

Bluetooth HC-06 with serial port module Easy guide 1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550

More information

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear. SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between

More information

INSTALLATION MANUAL XM3 Reader

INSTALLATION MANUAL XM3 Reader INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration

More information

PUSH BUTTON START INSTALLATION MANUAL

PUSH BUTTON START INSTALLATION MANUAL PUSH BUTTON START INSTALLATION MANUAL ALTHOUGH THIS PRODUCT HAS BEEN THOROUGHLY TESTED KPIERSON TECHNOLOGIES ASSUMES NO RESPONSIBILITY FOR ANY DAMAGE THAT MAY RESULT BY THE INSTALLATION OF THIS PRODUCT.

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

Class 2 transformer (TBT) Low Tension Conform to EN 60742. A LED turns ON when the current exceeds 1 A at the 14V output connector

Class 2 transformer (TBT) Low Tension Conform to EN 60742. A LED turns ON when the current exceeds 1 A at the 14V output connector Technical notice TECHNICAL CHARACTERISTICS Power Class 2 transformer (TBT) Low Tension Conform to EN 60742 Rechargeable battery 16 Vac, 50-60Hz 50 Va min. 250 Va max 12 V, 7AH Protection A LED turns ON

More information

Using your LED Plus keypad

Using your LED Plus keypad Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

VOICE RECORDING SYSTEM ISDN PRI / BRI

VOICE RECORDING SYSTEM ISDN PRI / BRI Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

What is a multimeter?

What is a multimeter? What is a multimeter? A multimeter is a devise used to measure voltage, resistance and current in electronics & electrical equipment It is also used to test continuity between to 2 points to verify if

More information

mdm-mp3 minidirector with MP3 Player

mdm-mp3 minidirector with MP3 Player minidirector with MP3 Player User Manual December 15, 2014 V1.02 Copyright Light O Rama, Inc. 2007, 2008 Table of Contents Introduction... 4 What s in the Box... 4 Hardware Utility Version... 5 Important

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally.

More information

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Applied Electronics. Commercial Dimming System UPDATE NOTICE REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with

More information

DSX Master Communications

DSX Master Communications DSX Access Systems, Inc. PC to Master Controller - Direct Connect Communications DSX Master Communications Communications between the Comm Server PC and the Master Controller can take several forms which

More information

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Instructions CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Catalog Number 2100-SD1 Description The Bulletin 2100 smoke detector unit is a 0.5 space factor unit for use in Bulletin

More information

TAC1 Telephone Entry System Installation and Programming Manual

TAC1 Telephone Entry System Installation and Programming Manual TAC Telephone Entry System 4 7 3 6 8 9 Installation and Programming Manual The Chamberlain Group 84 Larch Ave. Elmhurst, IL 66-96 www.liftmaster.com TABLE OF CONTENTS SPECIFICATIONS 3 Cable Requirements

More information

WIRELESS MAGNETIC CONTACT

WIRELESS MAGNETIC CONTACT WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:

More information

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

M68EVB908QL4 Development Board for Motorola MC68HC908QL4 M68EVB908QL4 Development Board for Motorola MC68HC908QL4! Axiom Manufacturing 2813 Industrial Lane Garland, TX 75041 Email: Sales@axman.com Web: http://www.axman.com! CONTENTS CAUTIONARY NOTES...3 TERMINOLOGY...3

More information

HyperAccess Access Control System

HyperAccess Access Control System Control System We manufacture, an advanced PC based access control solution that will give you control over who has access to your building. With you can control access on hundreds of doors for up to 10,000

More information

INSTALLATION & SERVICE MANUAL. Display Panel

INSTALLATION & SERVICE MANUAL. Display Panel INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed

More information

The service note describes the basic steps to install a ip camera for the DVR670

The service note describes the basic steps to install a ip camera for the DVR670 Tech note Description Adding IP camera to DVR670 General The service note describes the basic steps to install a ip camera for the DVR670 Steps involved: 1) Configuration Manager application 2) Camera

More information

WD-AMX Water Detection Controllers

WD-AMX Water Detection Controllers Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation

More information

FSLIMRF05-10 - 15-20 - 25

FSLIMRF05-10 - 15-20 - 25 1. INTRODUCTION FSLIMRF is a fully wireless, battery-powered infrared beam barrier for the protection of doors and windows with alarm radio transmission. The barrier is made up of two aluminium sections

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-A

More information

Speed Control Relays SX2

Speed Control Relays SX2 SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................

More information

F2400 FOM II Series Fiber Optic Modem Technical Manual

F2400 FOM II Series Fiber Optic Modem Technical Manual F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data

More information