Minimizing the Cost of Arc Flash Evaluation Studies

Size: px
Start display at page:

Download "Minimizing the Cost of Arc Flash Evaluation Studies"

Transcription

1 Minimizing the Cost of Arc Flash Evaluation Studies THIS ARTICLE IS AVAILABLE ONLINE AT FOR 30 DAYS FOLLOWING PUBLICATION. The electrical power system at a plant is often taken for granted. Unlimited power is assumed to be available, and the infrastructure of the power system is assumed to last forever. Even as new equipment is added or existing equipment is idled, little thought is given to the overall power system. Another overlooked area is arc flash and arc blast safety. Until recently, electrical safety was This paper examines the criteria required to perform an arc flash analysis on a steel producing facility, including what information can be gathered in-house and what must be completed by a licensed power systems engineer. A strategic program for minimizing outside costs is presented. often limited to shock hazards and lockout/tagout programs. Most safety programs focused on a worker coming in contact with energized parts. Recent changes to the National Fire Protection Act (NFPA 70E) and the National Electric Code (NEC) have compelled companies to address these areas by performing an arc flash hazard analysis. 1 2 The purpose of this analysis is to determine the potential risk of arc faults and arc blasts at every industrial panel to which a worker may be exposed. Based on this analysis, appropriate work practices and personal protective equipment (PPE) must be utilized to reduce the risks associated with arc flashes and arc blasts. A conservative method based on voltage level, type of task being performed, and standardized tables can be used to conduct this analysis. This method is simple and inexpensive in the short term, but often results in overprotection. When a worker is overly encumbered by PPE, productivity and morale are negatively impacted. This method also does not address ways of reducing PPE requirements through engineered solutions, such as using current-limiting fuses, using smaller transformers, etc. Another method of arc flash hazard analysis requires an engineered study. The available fault current is determined for each industrial panel based on voltage, overcurrent protection settings, utility contribution and equipment ratings. This type of analysis is more exact and often leads to less-restrictive PPE requirements. It also identifies problem areas and points within an electrical system that can be modified to further reduce PPE requirements by reducing the available fault current. This paper seeks to help companies minimize the cost of performing engineered studies for arc flash hazard analysis. Each step required to perform an arc flash hazard analysis will be detailed. The level of expertise required for each step will also be discussed (i.e., electrician, plant engineer, or licensed power system PE). Typical areas of concern for steel mills will also be addressed. Electrical Single Lines The basis for an engineered study is the electrical single lines. These drawings typically show the distribution of electrical power from the utility company down to the switchboard, motor control center (MCC) or panel level. Large-horsepower (hp) motors or MG sets are also included. Each item is assumed to be three-phase AC unless otherwise noted. All the breakers, fuses and protection relays that provide protection for the system are shown. Any switches, disconnects and tie-breakers are also shown (Figure 1). The vast majority of engineering studies input a plant s single lines into a software program for analysis. Since the study is only as accurate as the information put into this program, many of the single lines need to be field verified. Most plants do not have up-to-date single lines. As a result, the first step in performing an arc flash hazard analysis is walking through a plant and correcting the single line diagrams. Depending on the size of the plant, this can be a significant effort. In addition to verifying the actual connections shown on the single line, an engineered study requires the following information to be field verified: Author 134 Iron & Steel Technology Dan Laird, associate professor, Youngstown State University, Youngstown, Ohio (dlaird@ysu.edu)

2 Figure 1 Electrical single line drawing. Utility fault contribution and protective device information. Transformer nameplate information, including impedances and, if possible, X/R ratios. Nameplate fuse ratings. Nameplate breaker ratings and settings. Protective relay settings. Equipment ratings (symmetrical and asymmetrical ratings, voltage ratings, etc.). Motor/generator nameplate information (motors larger than 50 hp or large groups of motors that run simultaneously). Regenerative drive information. Conductor sizes, type and number per phase. Relative length of cable runs (±50 feet). Notation if cable is overhead (in free air) or in raceway/conduit. Bus duct ratings, lengths and loads. Gathering this information is the most critical part of the study. It is also the biggest opportunity for saving money by doing as much in-house as possible. Providing detailed information means that the power systems engineer needs to make fewer assumptions. When making engineering assumptions regarding life safety, an engineer will tend to be conservative. These conservative estimates can lead to overprotection one of the things to be avoided by doing an engineered study. The optimal condition is to have up-to-date single lines. If there is equipment missing or no longer in use, these drawings need to be updated. If there is too much information missing, an engineering firm cannot even quote the cost of performing an arc flash hazard analysis. The most cost-effective way of verifying the information is to have the plant electrician(s) red-line the single line drawings by hand. These red-lined drawings can be updated in electronic format at a later time. While the electrician is verifying these connections, nameplate data can be gathered on the transformers, motors, generators and other equipment. This can often be done by an engineering intern who has the appropriate safety training and the guidance of an engineer. A good safety practice is to always have the intern escorted by a qualified electrician at all times. (Note: Always follow the prescribed boundary distances for voltage rated equipment, even if escorted by qualified personnel.) Some information can be gathered safely only if the electrical equipment is de-energized. This includes conductor sizes, number of conductors, some relay settings, some breaker settings and fuse information. The ideal situation is to gather this information during a planned shutdown of the plant electrical system. Most of this information can be April

3 gathered by an engineering intern under the guidance of an engineer and with the assistance of a qualified electrician. If an outage is not possible, the next best solution for saving money is to spend time in the maintenance library. Any accurate cable and conduit schedule can be used to mark conductor size and number of conductors on the single line drawings. Previous calibration reports for protective relays and breakers can be used to gather nameplate ratings for each device and give the engineering consulting company a checklist from which to work. This will save time when collecting data and reduce the overall cost of the project. If digital trip units have been added to power circuit breakers, the settings for these devices can be tabulated and provided to the outside consulting company. Any records regarding fuse information, such as infrared studies, can also be useful. Keep track of any current-limiting-type fuses that have been installed so that the engineering firm does not need to conservatively use a non-current-limiting type in the computer model. Another crucial cost-saving opportunity is in obtaining an electronic copy of the computer model from the engineering consulting firm that performs the study. These firms typically provide a hard copy of their report and analysis, but most will provide it electronically as well, if requested. Constructing the electrical system database is the most time-consuming task for the engineering firm. Once the system is built into software, it is very easy to update the study as fuses are changed, lines are added or equipment is removed. Having an electronic copy of the database ensures that a complete database reconstruction will not have to be paid for a second time, even if a new consulting firm is chosen. Since the coordination of overcurrent protection devices in a plant should be examined at least every five to 10 years, it makes sense to have a model of the power system available. Many plants purchase their own copy of this modeling software (i.e., SKM, ETAP, etc.) to examine different scenarios, such as upgrading to current-limiting fuses, opening tiebreakers or replacing existing equipment. This software can be expensive and requires training to understand how changes are implemented, so this may or may not be a good value. Short-circuit Analysis Once the power system database has been constructed, a short-circuit analysis can be performed. This analysis determines the magnitude of available current throughout the power system at various time intervals following a fault. The computer model is used to determine the bolted three-phase short-circuit current at each point in the system. Once the fault levels have been calculated, they are compared to the withstand rating of the equipment in the electrical distribution system. For example, if a breaker is rated for 80,000 amps asymmetrical/50,000 amps symmetrical, it can withstand a first 1 /2 cycle of 80,000 amps and clear a fault of 50,000 amps. If the equipment is underrated, it can fail to operate properly and cause an even greater hazard than if it did not operate at all. Most software packages will generate a list of equipment that is not adequately braced as part of an equipment evaluation. Since all panels and breakers do not list the bracing information, the software may estimate typical ratings based on voltage and amperage. Paying to have the engineering consulting firm conduct an equipment evaluation implies they will track down the true ratings for all panels that are flagged by the software as not being adequately braced. It may be a cost savings to simply ask for a list of equipment that does not pass the equipment evaluation and verify the actual ratings using inhouse resources. If the information is not found on equipment nameplates, this means the equipment manufacturer should be contacted in order to obtain the true ratings. Protective Device Coordination Analysis A coordinated system is one in which the protective devices (circuit breakers, fuses, relays, etc.) operate at the proper times to eliminate or minimize the damage to a system. In the worst case, no protective devices will operate, resulting in risk to both equipment and personnel. If set too aggressively, the protective devices may operate for normal conditions, such as transformer magnetization and motor inrush current. It takes a significant degree of skill and experience to set the overcurrent protection properly. Significant changes in loading or equipment require revisiting this analysis every few years. In general, coordination studies are conducted from the loads to the source as identified below: Individual loads. Conductors. Distribution equipment: breakers, disconnect switches, etc. Transformers. High-voltage distribution to transformers. The above process is continued for each successive voltage level until the utility-controlled devices are reached. This process needs to performed by an experienced power 136 Iron & Steel Technology

4 Figure 2 Single line as drawn in modeling software. systems engineer. The adjustable settings on the overcurrent protection devices have a profound effect on both equipment protection and arc flash boundaries. Consider the coordination curve shown in Figure 3. Notice that all the protective relays are not set to trip before transformer T1 reaches full load current. All three relays will trip before thermal or mechanical damage occurs to the transformer. Only the relay on the secondary side of the transformer is set to trip faster than the transformer inrush. This is an example of a coordinated system. Copies of these coordination curves should come with the arc flash hazard analysis, as they provide the basis for setting available fault current. Arc Flash Hazard Analysis The next step in the study is to determine the incident energy at each point in the power system based on the previous information. These energy levels are only as accurate as the information garnered in the previous steps. There is also some latitude for engineering adjustments in performing the arc flash hazard analysis. A typical working distance of 18 inches is often used to give an average arm s length distance for the worker. The idea is to protect the face and torso, since burns over less than 25 percent of the body are less likely to be fatal (Figure 4). This is a sound estimate for working inside a panel or doing voltage checks. However, some tasks may not require the worker to be so close to the energized equipment. For example, a worker changing fuses in a fused disconnect cubicle may be more than 18 inches away from the main busbar, which carries a higher PPE rating. When switching operations are performed, it may be possible to use extended racking handles or hook sticks to increase the working distance. If areas in a plant show up on the arc flash study as having a PPE rating higher than Class 4, the study should be rerun with a working distance of 36 inches in these areas. If the result is less than a PPE rating of Class 4, a worker can perform those tasks beyond a working distance of 36 inches in PPE while the equipment is energized. This is particularly true for work done on medium- or high-voltage systems, where the only work performed while energized is switching or racking breakers in and out. Work that cannot be done from beyond 36 inches will have to be done when the system is de-energized. Another area of flexibility is in setting the maximum arcing duration in the arc flash hazard analysis. This permits the setting of a maximum (trip time + breaker time) for the incident energy and flash boundary calculations. IEEE 1584 Annex B.1.2 states, If the time is longer than 2 seconds, consider how long a person is likely to remain in the location of the arc flash. It is likely that the person exposed to arc flash will move away quickly if April

5 Figure 3 Transformer protection curve.3 it is physically possible, and 2 seconds is a reasonable maximum time for calculations. A person in a bucket truck or a person who has crawled into equipment will need more time to move away. This 2-second approximation has caused much debate among power systems engineers. Many engineering firms will run the study with a longer maximum clearing time first. If the analysis shows some restrictive PPE requirements in an area of frequent work, the study may be rerun at the 2-second clearing time. In this case, it should be stressed to the owner of the electrical system that the arc may in fact last longer than 2 seconds and that not every task is suitable for this assumption. 138 Iron & Steel Technology PPE Requirements Once the incident energy is calculated at the working distance for each point in the system, suitable PPE can be prescribed for that level of energy. Table 1, from NFPA 70E, shows the PPE hazard category and minimum arc thermal performance exposure values. Many companies provide their workers with a uniform that meets Class 1 requirements and have Class 2 and Class 4 PPE kits available for all other tasks. In this case, a worker will wear Class 4 PPE for hazard categories 3 and 4. A common mistake is to purchase PPE before the study is completed, only to find out that it is inadequate or overkill for most tasks performed in the plant. There is also the possibility that PPE requirements can be relaxed

6 Figure 4 if fuses or breaker settings are changed, more information becomes available at the next planned outage, or equipment is replaced. If a plant has only a few Class 4 locations, it may not make sense to purchase Class 4 PPE for every maintenance worker. The application of arc flash labels, employee training and issuing of PPE should ideally happen at the same time, but all these tasks should be based on the results of the study. Otherwise, it may be necessary to do these tasks twice and incur additional costs. Items Particular to the Steel Industry Electrical power systems for steel producers have some unique features. Below are some common concerns for arc flash hazard analysis: DC Systems There is currently no arc flash standard for DC systems. The IEEE 1584 method currently used to perform most arc flash evaluations is based on experiments conducted in high-power laboratories on AC systems. Until enough experimental data exists for DC systems, arc flash analysis must stop at the rectifiers converting AC to DC. When a standard is developed, it will pay to have the electronic copy of the database on hand to quickly rerun the arc flash hazard analysis for the plant. Probability of survival after a burn injury. Regenerative Systems Bridle and winder motors are often running in regeneration mode, i.e., they are sending energy back to the incoming line during normal operation. On a fault condition, this added energy from regenerating motors must be applied to the short-circuit study. The engineering consulting firm should be assisted in identifying which motors operate in regeneration, especially if the firm is not familiar with the steel industry. Open Commutators Many commutators on large motors and generators in a steel mill are open to ambient air. This creates a situation where entire motor rooms are in the flash zone of the motor or generator at all times. Since these rooms often house variable speed drives, MCCs or switchgear, restrictive PPE must be worn even for routine tasks. It may be necessary to partition motor rooms to avoid cumbersome PPE for everyday tasks. Exposed Busbar Many steel mills have exposed busbar on slate panels, crane rails or processes like electrolytic cleaners. Again, these conductors are considered exposed at Table 1 NFPA 70 E PPE Hazard Category and Minimum Arc Thermal Performance Exposure Values Minimum arc thermal performance exposure value (ATPV)* or Hazard/risk Clothing description Total weight breakopen threshold energy (E BT )* Category (number of clothing layers in parentheses) (oz./yd. 2 ) rating of PPE cal/cm 2 0 Untreated cotton (1) N/A 1 FR shirt and FR pants (1) Cotton underwear plus FR shirt and FR pants (2) Cotton underwear plus FR shirt and FR pants plus FR coverall (3) 4 Cotton underwear plus FR shirt and FR pants plus double-layer switching coat and pants (4) *ATPV is defined in the ASTM P S58 standard arc test method for flame-resistant (FR) fabrics as the incident energy that would just cause the onset of a second-degree burn (1.2 cal/cm 2 ). E BT is reported according to ASTM P S58 and is defined as the highest incident energy which did not cause FR fabric breakopen and did not exceed the second-degree burn criteria. E BT is reported when ATPV cannot be measured due to FR fabric breakopen. April

7 all times, and workers would be within their flash zones under normal circumstances. The solution may not be PPE, but finding creative ways to either contain the energized parts or keep workers at a safe distance. Arc Furnaces The process of making steel can require very high-powered electrical systems and large transformers. Working in these areas may affect not only electrical maintenance workers, but production workers as well. The approach boundaries for unqualified individuals can be prohibitive. Engineering creativity is again needed to shield workers from the exposed energized equipment at greater distances than currently maintained in most steelmaking facilities. Summary Companies are required to perform an arc flash hazard analysis by NFPA 70 E. Choosing to do an engineered study will provide a safe and accurate assessment of arc flash hazards and provide options for making a plant a safer place to work. These options can include PPE, design changes or equipment changes. These studies should be performed by an experienced power systems engineer. Much of the information required by the power systems engineer can be obtained using in-house resources as outlined above. The cost of future studies can be minimized by obtaining an electronic copy of the modeling database. The cost of equipment evaluation can be minimized by acquiring equipment bracing information using in-house resources. Calculating the working distance based on the task performed can reduce PPE requirements. Creativity can be applied to increase the safe working distance and ultimately reduce PPE requirements. Care should be taken to avoid ordering the incorrect PPE. It is recommended that a PPE plan be developed based on the results of the engineered study. The steel industry has its own unique concerns relative to arc flash. They can be considered and acted upon prior to performing an engineered study in many cases. References 1. National Fire Protection Association Inc., NFPA 70E: Electrical Safety Requirements for Employee Workplaces, 2004 Edition, National Fire Protection Association Inc., National Electric Code 2005, Article , Barr, Edward, Coordination of the Kraft Facility Philadelphia, Pa., Reuter Hanney Inc., May American Burn Association, National Burn Repository 2002 Report: Percent Survival Versus Age Range, March IEEE, IEEE Standard Guide for Performing Arc-flash Hazard Calculations, This paper was presented at AISTech 2006 The Iron & Steel Technology Conference and Exposition, Cleveland, Ohio, and published in the AISTech 2006 Proceedings. DID YOU KNOW? December 2006 Steel Shipments Down 11.8 Percent From Previous Year The American Iron and Steel Institute reported that, for the month of December 2006, U.S. steel mills shipped 7,609,000 net tons, an 11.8 percent decrease from the 8,513,000 net tons shipped in December 2005, and a 5.0 percent decrease from the 7,991,000 net tons shipped in the previous month, November A year-to-year comparison of year-to-date shipments shows the following changes within major market classifications: service centers and distributors, up 2.1 percent; automotive, up 7.5 percent; construction and contractors products, up 10.6 percent; oil and gas, up 19.6 percent; machinery, industrial equipment and tools, up 4.6 percent; appliances, utensils and cutlery, down 6.0 percent; containers, packaging and shipping materials, up 1.2 percent; and electrical equipment, up 12.8 percent. 140 Iron & Steel Technology

Understanding Arc Flash

Understanding Arc Flash Understanding Arc Flash Presented by Eddie F. Jones, PE 1 2 3 4 5 Five to 10 arc flash explosions occur in electric equipment every day in the United States. This number does not include cases in which

More information

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E Training is not a substitute for following corporate safety guidelines. Always refer to the latest safety

More information

Introduction to Arc Flash

Introduction to Arc Flash Introduction to Arc Flash Worker Training of Electrical Hazards Including Arc Flash SH-16614-7 This material was produced under grant number SH-16614-7 from the Occupational Safety and Health Administration,

More information

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer DanRNeeser@Eaton.com. Electrical Hazards 2/18/2015. Shock.

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer DanRNeeser@Eaton.com. Electrical Hazards 2/18/2015. Shock. Arc Flash Hazards Dan Neeser Field Application Engineer DanRNeeser@Eaton.com Electrical Hazards Electrical Hazards Shock Arc Flash Arc Blast 2 1 Arcing Fault Basics 35,000 F Radiant Heat & UV Speed of

More information

2013WWOA Conference Technical Conference Program

2013WWOA Conference Technical Conference Program 2013WWOA Conference Technical Conference Program Understanding Arc-Flash Hazards, Its Implications on Operations and Solutions that Mitigate Such Exposure Presented by Jerry Baskin Senior Product Manager

More information

misconceptions about arc-flash hazard assessments

misconceptions about arc-flash hazard assessments misconceptions about arc-flash hazard assessments There are some common misconceptions about Arc-Flash Hazard Assessments which reduce the effectiveness of the Assessments and can increase electrical hazards.

More information

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Arc Flash Avoidance and its Application to Overhead Traveling Cranes Arc Flash Avoidance and its Application to Overhead Traveling Cranes Whitepaper August 2012 Jason Wellnitz, Controls Product Manager Material Handling Numerous technical papers, bulletins, magazine articles

More information

A Guide to Performing An Arc Flash Hazard Assessment Using Power Analysis Software

A Guide to Performing An Arc Flash Hazard Assessment Using Power Analysis Software A Guide to Performing An Arc Flash Hazard Assessment Using Power Analysis Software Abstract: The nature of explosive equipment failures, and the rate of serious burn injuries in the electrical industry

More information

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers A market position paper from the experts in Business-Critical Continuity TM Executive Summary Electrocutions are the fourth

More information

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS ARC FLASH CALCULATIONS & LABELING REQUIREMENTS Presented by: Edmund Elizalde EYP Mission Critical Facilities, Inc. Slides by: Lonnie Lindell SKM Systems Analysis, Inc. 1 Agenda NEC 110.16 NFPA 70E IEEE

More information

NFPA 70E Updates Affect Your Most Valuable Assets

NFPA 70E Updates Affect Your Most Valuable Assets NFPA 70E Updates Affect Your Most Valuable Assets EXECUTIVE SUMMARY Electrocution is a well-known hazard associated with direct contact with electrical energy. According to the U.S. Department of Labor,

More information

Part 1 System Modeling & Studies for Existing Systems

Part 1 System Modeling & Studies for Existing Systems Part 1 System Modeling & Studies for Existing Systems Operation Technology, Inc. Copyright 2009 Result of rapid release of energy due to an arcing fault between two conductors. Bus voltages > 208V Temperatures

More information

What s up with Arc Flash?

What s up with Arc Flash? What s up with Arc Flash? Presented by Mark Haskins, CSP Practical Safety Solutions, LLC CONN OSHA Breakfast Roundtable February 18, 2014 2014 Practical Safety Solutions, LLC What is Arc Flash? Definition

More information

90.2(A) Covered & 90.2(B) Not Covered 6/23/2015. Learning Objectives. 90.2(A) Covered & 90.2(B) Not Covered. Change Summary

90.2(A) Covered & 90.2(B) Not Covered 6/23/2015. Learning Objectives. 90.2(A) Covered & 90.2(B) Not Covered. Change Summary Learning Objectives After reviewing this material, the student will be able to: 1. Identify the installations that fall under the scope of the 2015 edition of NFPA 70E. 2. Identify the assessments required

More information

Analyzing Electrical Hazards in the Workplace

Analyzing Electrical Hazards in the Workplace Analyzing Electrical Hazards in the Workplace By Dennis K. Neitzel, CPE AVO Training Institute, Inc. The need for analyzing electrical hazards in the workplace has been recognized by a small segment of

More information

ARC FLASH HAZARD OVERVIEW. Presented August 13, 2015 WWOA Lake Michigan District by Mead & Hunt, Inc.

ARC FLASH HAZARD OVERVIEW. Presented August 13, 2015 WWOA Lake Michigan District by Mead & Hunt, Inc. ARC FLASH HAZARD OVERVIEW Presented August 13, 2015 WWOA Lake Michigan District by Mead & Hunt, Inc. ARC FLASH EXPERIENCE Christopher J. DeWaal, MS, MEM, PE, LEED AP, HACCP How did I get involved? A client

More information

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear. Arc Flash Mitigation Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear. Distance is Safety We will discuss through examples of actual occurrences and possible

More information

2012 NFPA 70E. Ten Most Important Changes. John A. DeDad

2012 NFPA 70E. Ten Most Important Changes. John A. DeDad 2012 NFPA 70E Ten Most Important Changes John A. DeDad GE Energy Management 41 Woodford Avenue Plainville, CT 06062 USA 860-747-7344 John.dedad@ge.com Abstract The 2012 Edition of NFPA 70E, Standard for

More information

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin? What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin? Comparing apples-to-apples bids Plant Services Special Report A shock hazard analysis should be included as part of an arc

More information

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for commercial and industrial facilities Executive Summary

More information

SAFE ELECTRICAL WORK PRACTICES & 2015 NFPA 70E

SAFE ELECTRICAL WORK PRACTICES & 2015 NFPA 70E SAFE ELECTRICAL WORK PRACTICES & 2015 NFPA 70E This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of the program

More information

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for data centers Executive Summary Every three years, the

More information

Short Circuit Current Calculations

Short Circuit Current Calculations Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that

More information

! WARNING Arc Flash and Shock Hazard Appropriate PPE Required

! WARNING Arc Flash and Shock Hazard Appropriate PPE Required Arc Flash Hazard Labeling Do s and Don ts! WARNING Arc Flash and Shock Hazard Appropriate PPE Required 11' - 3" Flash Hazard Boundary 9 cal/cm2 Flash Hazard at 18 inches #3 PPE Level Cotton underwear plus

More information

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity Proper Application of 415V Systems in North American Data Centers A White Paper from the Experts in Business-Critical Continuity Introduction Increasing pressure to reduce operating expenses and be more

More information

The Other Hazard of Electricity. Larren Elliott Ph.D. Lindsay Polic, CSP, REHS

The Other Hazard of Electricity. Larren Elliott Ph.D. Lindsay Polic, CSP, REHS The Other Hazard of Electricity Larren Elliott Ph.D. Lindsay Polic, CSP, REHS Presenters Larren Elliott Ph.D. EORM Electrical Safety Service Partner 45 years practical and hands-on industrial experience

More information

2008 Eaton Corporation. All rights reserved.

2008 Eaton Corporation. All rights reserved. FlashGard TM Motor Control Center Electrical Safety Hazards Design Philosophy The Product 2008 Eaton Corporation. All rights reserved. Research studies say. Five to 10 arc flash explosions occur in electrical

More information

INTRODUCTION ARC FLASH PROTECTION AND SAFETY MEASURES. September 2010

INTRODUCTION ARC FLASH PROTECTION AND SAFETY MEASURES. September 2010 ARC FLASH PROTECTION AND SAFETY MEASURES September 2010 Introduction Hazards of Electrical Energy Electrical Safety Program Safety-Related Work Practices Electrical Safety Procedures Presented By: Ken

More information

Choosing the Best Solution for Reducing Arc Energy

Choosing the Best Solution for Reducing Arc Energy CONVENTION SESSION HANDOUT Choosing the Best Solution for Reducing Arc Energy Terry L. Schiazza, Business Development Manager Square D / Schneider Electric SESSION #11 Independent Electrical Contractors

More information

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.) Common Electrical Hazards in the Workplace Including Arc Flash Presented by Ken Cohen, PhD, PE & CIH (Ret.) 1 What s New In February 1972, OSHA incorporated the 1971 edition of the National Fire Protection

More information

Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26

Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26 Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26 Assessing The Hazards Of High and Low Voltage Single-Phase Arc-Flash By Albert Marroquin One common question

More information

Procedure Number 1022. Arc Flash Hazard Calculation and Required Protection Revision 5. TVA Safety Procedure Page 1 of 25. 1.

Procedure Number 1022. Arc Flash Hazard Calculation and Required Protection Revision 5. TVA Safety Procedure Page 1 of 25. 1. TVA Safety Procedure Page 1 of 25 Arc Flash Hazard Calculation and 1. Purpose April 30, 2007 1.1. This procedure defines TVA s method for calculating the electric arc flash incident energy at various distances,

More information

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves White Paper July 2010 Integrating surge protective devices (SPD) into distribution equipment (i.e. switchgear, switchboards,

More information

Technical Guide. SKM Arc Flash Line Side vs. Load Side

Technical Guide. SKM Arc Flash Line Side vs. Load Side SKM Arc Flash Line vs. Load The option of choosing the line-side or the load-side arc flash incident energy for arc flash labels is an important decision when performing an arc flash hazard analysis. When

More information

Low Voltage Circuit Breakers. Arc flash hazards

Low Voltage Circuit Breakers. Arc flash hazards Low Voltage Circuit Breakers Arc flash hazards Index Low voltage selectivity with ABB circuit breakers Introduction... 2 Definitions, acronyms and terms used... 3 Electrical arcs and their dangerous effects

More information

Electrical Safety Program

Electrical Safety Program California State University-Fullerton 800 N. State College Blvd. Fullerton, CA 92831 Prepared by: Paul A Zoubek, CSP, CIH President/Principal Consultant Zoubek Consulting, LLC 3737 Granada Ave. San Diego,

More information

The Three A s of Arc Flash

The Three A s of Arc Flash The Three A s of Arc Flash Gary H. Fox, PE Senior Specification Engineer In 2007 GE conducted a survey of industry professionals working in facilities related to the oil and gas industry, pulp and paper

More information

IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS

IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS Paul A Zoubek, CSP, CIH Occupational Services, Inc. San Diego, CA 619-861 861-0612 paul@occsev.com OCCUPATIONAL SERVICES, INC. BACKGROUND Update Update

More information

Roadmap to Compliance with NFPA 70E Arc Flash Requirements

Roadmap to Compliance with NFPA 70E Arc Flash Requirements Roadmap to Compliance with NFPA 70E Arc Flash Requirements TAHFM Interlink 2015 March 30, 2015 Antony Parsons, Ph.D., P.E. Schneider Electric Engineering Services 1 2 How do we get to Reliable Power? >

More information

Safety By Design. Strategies for Electrical Contractors

Safety By Design. Strategies for Electrical Contractors Safety By Design Strategies for Electrical Contractors Introduction Engineering and system design significantly impact worker safety System design provides opportunity to eliminate/minimize workers exposure

More information

Arc Flash Energy Mitigation Techniques

Arc Flash Energy Mitigation Techniques Arc Flash Energy Mitigation Techniques When short circuits occur on an electrical distribution system, an arc flash event usually forms. These arc flash events can cause dangerous and potentially fatal

More information

ETAP Arc Flash Analysis

ETAP Arc Flash Analysis ETAP Arc Flash Analysis The purpose of this tutorial is to introduce the Arc Flash Analysis module of ETAP and provide instructions on how to setup Arc Flash (AF) calculations. For this section of the

More information

A USERS GUIDE TO ARC RESISTANT LOW VOLTAGE SWITCHGEAR & MOTOR CONTROL ANALYTICAL COMPARISON VS ARC FLASH TEST RESULTS

A USERS GUIDE TO ARC RESISTANT LOW VOLTAGE SWITCHGEAR & MOTOR CONTROL ANALYTICAL COMPARISON VS ARC FLASH TEST RESULTS A USERS GUIDE TO ARC RESISTANT LOW VOLTAGE SWITCHGEAR & MOTOR CONTROL ANALYTICAL COMPARISON VS ARC FLASH TEST RESULTS By: Gabriel Arce, ABB, San Luis Potosi, Mexico Casey McCollum, ABB, Houston, TX John

More information

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS David D. Roybal, P.E. Senior Member, IEEE Eaton Electrical 3697 Mount Diablo Boulevard Lafayette, CA 94549 Abstract Low-voltage circuit

More information

100% Rule Alternate Method Arc Blast Arc Flash Approved Approved Equipment Authority Having Jurisdiction (AHJ) Authorized Work Bare Hand Work

100% Rule Alternate Method Arc Blast Arc Flash Approved Approved Equipment Authority Having Jurisdiction (AHJ) Authorized Work Bare Hand Work Definitions 100% Rule Work on or near energized parts must be performed only after all participating qualified electrical workers are in 100% agreement on the work to be completed, on the sequence in which

More information

SALISBURY ASSESSMENT SOLUTIONS

SALISBURY ASSESSMENT SOLUTIONS SALISBURY ASSESSMENT SOLUTIONS Electrical engineering services for a safe and compliant workplace Electrical Safety Program Assessments - Electrical Safety Training Arc Flash Risk Assessments - Power Systems

More information

ARC Flash Boundary & NFPA-70E Requirements PPE Program

ARC Flash Boundary & NFPA-70E Requirements PPE Program ARC Flash Boundary & NFPA-70E Requirements PPE Program 1. Purpose and Scope The Arc Flash Boundary - PPE Program was developed to minimize the risk to AMS employees from safety and health hazards in the

More information

How to reduce exposure to arc flash hazards

How to reduce exposure to arc flash hazards GE Energy Industrial Solutions How to reduce exposure to arc flash hazards Multiple solutions for new and existing facilities imagination at work Multiple Issues Today s power system engineer must not

More information

Written Program ELECTRICAL SAFETY. Based on OSHA Subpart S and NFPA 70E Standards

Written Program ELECTRICAL SAFETY. Based on OSHA Subpart S and NFPA 70E Standards Written Program ELECTRICAL SAFETY Based on OSHA Subpart S and NFPA 70E Standards Revised November 2012 Disclaimer The presentations and program provided by Workplace Safety Solutions, Inc. are based on

More information

Midwest Healthcare Engineering Conference and Trade Show 2012 Indianapolis, Indiana

Midwest Healthcare Engineering Conference and Trade Show 2012 Indianapolis, Indiana Midwest Healthcare Engineering Conference and Trade Show 2012 Indianapolis, Indiana Arc Flash Overview An engineering solutions company November 7, 2012 Agenda Introductions Arc Flash defined History and

More information

ELECTRICAL & ARC FLASH SAFETY PROGRAM

ELECTRICAL & ARC FLASH SAFETY PROGRAM ELECTRICAL & ARC FLASH SAFETY PROGRAM ADOPTED VERSIO 2, SEPTEMBER 26, 2012 Supercedes all prior versions A. COMMITTEE OVERSIGHT OF PROGRAM The University of Montana ( University ) recognizes the importance

More information

A Survey of Arc Flash Computation Methods and Mitigation Strategies By Dr. Carl J. Spezia

A Survey of Arc Flash Computation Methods and Mitigation Strategies By Dr. Carl J. Spezia Volume 26, Number 2 - April 20 through June 20 A Survey of Arc Flash Computation Methods and Mitigation Strategies By Dr. Carl J. Spezia Peer-Refereed Perspective Papers Keyword Search Electricity Energy

More information

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE Appendix B-2 - Electrical Safety In Design Final Report TECHNOLOGIES THAT REDUCE LIKELIHOOD OF INJURY FROM ELECTRICAL HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE The following are technologies that reduce

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

Campus Safety Procedure Electrical Safety

Campus Safety Procedure Electrical Safety Campus Safety Procedure Electrical Safety Electrical Safety Procedures 1.0 Purpose The purpose of this procedure is to provide guidance in the performance of work on electrical systems, wiring, and equipment

More information

RISK MITIGATION for ELECTRICAL WORK. Feb 2013 San Diego CA

RISK MITIGATION for ELECTRICAL WORK. Feb 2013 San Diego CA RISK MITIGATION for ELECTRICAL WORK Feb 2013 San Diego CA Agenda I. RISK Define the Risks Arc Flash Review II. MITIGATION 3 Easy Steps New Designs Vs. Existing Systems III. DUKE UNIVERSITY EXAMPLE I. Risk

More information

Arc Flash Mitigation. Executive summary. by Antony Parsons, Ph.D., P.E.

Arc Flash Mitigation. Executive summary. by Antony Parsons, Ph.D., P.E. by Antony Parsons, Ph.D., P.E. Executive summary Arc flash events can result in significant injury to workers, including severe burn injuries. The most effective arc flash safety programs are not those

More information

ELECTRICAL SAFETY RISK ASSESSMENT

ELECTRICAL SAFETY RISK ASSESSMENT ELECTRICAL SAFETY RISK ASSESSMENT The intent of this procedure is to perform a risk assessment, which includes a review of the electrical hazards, the associated foreseeable tasks, and the protective measures

More information

Demystifying arc flash hazard management

Demystifying arc flash hazard management Demystifying arc flash hazard management Presented by Matt Brazier Senior Electrical Engineer Gove Operations November 2013 Standard NFPA 70E IEEE 1584 AS/NZS 4836 TERMINOLOGY Arc arc flash hazard analysis

More information

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT Are You Ready For The New SCCR Marking Requirements? What Is A Short-Circuit Current Rating (SCCR)? SCCRs on components

More information

PRESENTED AT THE 2011 IEEE IAS PULP & PAPER INDUSTRY TECHNICAL CONFERENCE, NASHVILLE, TN: IEEE 2011 - PERSONAL USE OF THIS MATERIAL IS PERMITTED.

PRESENTED AT THE 2011 IEEE IAS PULP & PAPER INDUSTRY TECHNICAL CONFERENCE, NASHVILLE, TN: IEEE 2011 - PERSONAL USE OF THIS MATERIAL IS PERMITTED. Arc Flash Energy Reduction Techniques Zone Selective Interlocking & Energy-Reducing Maintenance Switching Christopher G. Walker Senior Member, IEEE Eaton Corporation Moon Township, PA 15108 chrisgwalker@eaton.com

More information

OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010

OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010 OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010 By: Martin Robinson, Level III Thermographer 18-1030-0005 Rev. A The National Fire Protection Association (NFPA)

More information

How to Build a Safe and Effective Electrical Maintenance Program

How to Build a Safe and Effective Electrical Maintenance Program How to Build a Safe and Effective Electrical Maintenance Program The Business Case Ask Yourself the Following Questions: What is your dependence on electrical energy and control systems? What are the consequences

More information

Implementation of arc flash mitigating solutions at industrial manufacturing facilities

Implementation of arc flash mitigating solutions at industrial manufacturing facilities Thought leadership White paper Implementation of arc flash mitigating solutions at industrial manufacturing facilities David B. Durocher Senior Member, IEEE Global Industry Manager Eaton 26850 SW Kinsman

More information

Arc Flash Mitigation & Selective Co-ordination

Arc Flash Mitigation & Selective Co-ordination Arc Flash Mitigation & Selective Co-ordination Michael Hodder March 2015 Overview This seminar will provide information on: Mitigating arc flash hazards Selective Coordination What can we do to make these

More information

PROCEDURES FOR SAFE WORKING AND TESTING OF ENERGIZED ELECTRICAL EQUIPMENT

PROCEDURES FOR SAFE WORKING AND TESTING OF ENERGIZED ELECTRICAL EQUIPMENT Human Resources Support Services Health, Wellness and Safety PROCEDURES FOR SAFE WORKING AND TESTING OF ENERGIZED ELECTRICAL EQUIPMENT 1 SCOPE The electrical safety procedure shall be part of the Peel

More information

TAMPA ELECTRIC COMPANY ENERGY SUPPLY ELECTRICAL SAFETY PROGRAM

TAMPA ELECTRIC COMPANY ENERGY SUPPLY ELECTRICAL SAFETY PROGRAM TABLE OF CONTENTS TITLE PAGE # PURPOSE / INTRODUCTION 1 SCOPE 2 RESPONSIBILITY 3 EMPLOYEE TRAINING INCLUDING DOCUMENTATION 4 ELECTRICAL EQUIPMENT LABELING 5 APPROACH DISTANCES AND BOUNDARIES 5-8 GENERAL

More information

Low Voltage Transformer Through-Fault Protection: A System Approach

Low Voltage Transformer Through-Fault Protection: A System Approach Data Bulletin 7400DB1001 Nashville, TN USA Low Voltage Transformer Through-Fault Protection: A System Approach Introduction Low Voltage Transformer Protection Criteria NEC Article 450 Transformers and

More information

Engineering innovation

Engineering innovation Eaton's Electrical Engineering Services & Systems Solutions Focus Seamless Solutions for Reliable, Efficient and Safe Power Systems Engineering innovation Progressive solutions for today s power systems

More information

Predictive Maintenance

Predictive Maintenance PART ONE of a predictive maintenance series Predictive Maintenance Overview Predictive maintenance programs come in all shapes and sizes, depending on a facility s size, equipment, regulations, and productivity

More information

We will produce a colored custom Arc Flash Label that will list the following items:

We will produce a colored custom Arc Flash Label that will list the following items: Congratulations on your decision to have an Arc Flash Hazard Analysis (Arc Flash Study) performed at your facility. You are on your way to complying with OSHA your State regulations and making your facility

More information

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV MEDIUM VOLTAGE SUBSTATION PRACTICES MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV MEDIUM VOLTAGE SUBSTATION PRACTICES This presentation covers some safety aspects

More information

OSHA Published First-Ever Arc Flash Protection Requirements for the Electric Power Industry Significant changes and unprecedented compliance

OSHA Published First-Ever Arc Flash Protection Requirements for the Electric Power Industry Significant changes and unprecedented compliance OSHA Published First-Ever Arc Flash Protection Requirements for the Electric Power Industry Significant changes and unprecedented compliance deadlines require high-voltage facilities to take immediate

More information

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5 White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC

More information

Hampshire College. Lockout/Tagout and Electrical Safety Program and Procedures

Hampshire College. Lockout/Tagout and Electrical Safety Program and Procedures Hampshire College Lockout/Tagout and Electrical Safety Program and Procedures January 2007 In Compliance with the OSHA 29 CFR 1910.147 and 29 CFR 1910.331 through.335 And NFPA 70E Environmental Health

More information

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited Electrical Wiring Methods, Components and Equipment for General Use Approved for Public Release; Further Dissemination Unlimited At the completion of this unit you shall be able to: 1. Utilize section

More information

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER

More information

Electrical Safety in the Marine Environment

Electrical Safety in the Marine Environment January 3, 2001 TEHNIAL BULLETIN 010 Electrical Safety in the Marine Environment Approach Boundaries Electrical Safety in the Marine Environment presented by adick orporation 1 Overview Electrical power

More information

ACCEPTANCE TESTING, COMMISSIONING & START UP PREDICTIVE & PREVENTATIVE ELECTRICAL TESTING SERVICES ENGINEERING SERVICES

ACCEPTANCE TESTING, COMMISSIONING & START UP PREDICTIVE & PREVENTATIVE ELECTRICAL TESTING SERVICES ENGINEERING SERVICES INFRARED INSPECTIONS ACCEPTANCE TESTING, COMMISSIONING & START UP PREDICTIVE & PREVENTATIVE ELECTRICAL TESTING SERVICES ENGINEERING SERVICES 24/7 EMERGENCY SERVICE AND REPAIR DELIVERING A HOST OF TECHNICAL

More information

OSHA & ARC FLASH HAZARD ANALYSIS

OSHA & ARC FLASH HAZARD ANALYSIS OSHA & ARC FLASH HAZARD ANALYSIS Impact of Revisions to the OSHA Electrical Safety Regulations Presented by: John J. Kolak, MS, CSP Introduction Important Definitions Understanding OSHA Applicable standards

More information

Bypass transfer switch mechanisms

Bypass transfer switch mechanisms Power topic #6013 Technical information from Cummins Power Generation transfer switch mechanisms > White paper By Gary Olson, Director, Power Systems Development This paper describes the configuration

More information

Understanding the Standards Surrounding Arc Flash Hazards and Arc Resistant Equipment

Understanding the Standards Surrounding Arc Flash Hazards and Arc Resistant Equipment Understanding the Standards Surrounding Arc Flash Hazards and Arc Resistant Equipment 1 Rev 5058-CO900E This presentation contains many hidden slides that are provided for the presenters information and/or

More information

Electrical Safety in the Workplace

Electrical Safety in the Workplace Electrical Safety in the Workplace NFPA 70 E Presented by Sabine Mueller What Made Sabine Choose Such a DRY Topic? Ulterior Motive Metso Mueller Engineering has been visiting many scrap yards two or more

More information

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY 2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY Thomas P. McNamara, P.E. Manager, Development Engineering ABB Inc. Power Technologies Medium

More information

Report on Proposals June 2011 NFPA 70E. 70E-1 Log #7 EEW-AAA

Report on Proposals June 2011 NFPA 70E. 70E-1 Log #7 EEW-AAA 70E-1 Log #7 EEW-AAA Palmer L. Hickman, National Joint Apprentice & Training Committee Revise text as follows: This edition of,, was prepared by the Technical Committee on Electrical Safety in the Workplace

More information

Electrical Safety Program

Electrical Safety Program CALIFORNIA STATE UNIVERSITY, STANISLAUS Electrical Safety Program LAST UPDATED 6/2/11 CALIFORNIA STATE UNIVERSITY, STANISLAUS ELECTRICAL SAFETY PROGRAM TABLE OF CONTENTS 1.0 Purpose......2 2.0 Scope......2

More information

Hyperlinks are Inactive

Hyperlinks are Inactive Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

THE reliability, cost, and safety of electricity and industrial

THE reliability, cost, and safety of electricity and industrial IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 50, NO. 5, SEPTEMBER/OCTOBER 2014 1 The Journey of an Enterprise in a Process Industry Toward Improved Electrical Workplace Safety Greg M. Kemper, Senior

More information

Who sets the rules for electrical testing and safety?

Who sets the rules for electrical testing and safety? Who sets the rules for electrical testing and safety? Application Note Alphabet soup There s no question that electrical safety is a key concern for electricians and engineers, their employers, unions

More information

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

ELECTRICAL SAFETY. The standard unit for measuring electrical current. ELECTRICAL SAFETY Introduction The following sections provide general safety guidelines and procedures for electrical safety. This chapter covers the following topics: TOPIC PAGE General Electrical Safety

More information

Progress in Impacting Policy in Workplace Electrical Safety

Progress in Impacting Policy in Workplace Electrical Safety Progress in Impacting Policy in Workplace Electrical Safety H. Landis Lanny Floyd II, PE, CSP, CMRP, Fellow IEEE Principal Consultant Electrical Safety & Technology The miracles of science TM NIOSH PtD

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

Current Transformers

Current Transformers Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 Current Transformers Current transformers (CT's) provide

More information

UL Validated Testing of Arc-Resistant Motor Control Centers

UL Validated Testing of Arc-Resistant Motor Control Centers UL Validated Testing of Arc-Resistant Motor Control Centers Ensure Protective Features Perform as Designed Larry Sifers Account Manager Littleton, CO Siemens Industry June 1st - 3rd, 2011 Western Mining

More information

UNIVERSITY OF CENTRAL FLORIDA ELECTRICAL SAFETY PROGRAM

UNIVERSITY OF CENTRAL FLORIDA ELECTRICAL SAFETY PROGRAM UNIVERSITY OF CENTRAL FLORIDA ELECTRICAL SAFETY PROGRAM December 2011 Table of Contents UNIVERSITY OF CENTRAL FLORIDA... 0 Table of Contents... 1 INTRODUCTION... 2 PURPOSE... 2 SCOPE... 3 RESPONSIBILITIES...

More information

Using Infrared Sightglasses to Protect Against Arc-Flash Exposure

Using Infrared Sightglasses to Protect Against Arc-Flash Exposure Using Infrared Sightglasses to Protect Against Arc-Flash Exposure Antony J. Holliday IEEE Member Hawk IR International, Ltd. 117 High Street, Marske-by-Sea Redcar, Cleveland TS116JX, United Kingdom Ph:

More information

ARC FLASH HAZARD MITIGATION. Industrial Tests, Inc. [indtests.com]

ARC FLASH HAZARD MITIGATION. Industrial Tests, Inc. [indtests.com] ARC FLASH HAZARD MITIGATION ARC FLASH HAZARD MITIGATION NWHA TECHNICAL SEMINAR May 17, 2012 Richard D Reese Power Systems Manager Industrial Tests, Inc. Rocklin, California [Dick@indtests.com; 916-660-2837]

More information