User and Installer Handbook

Size: px
Start display at page:

Download "User and Installer Handbook"

Transcription

1 User and Installer Handbook Tapworks Softener Models Ultra 9, AD11 & AD15 Thank you for choosing Tapworks to supply your soft water. We are confident that you will be pleased with your purchase and would encourage you to read this installation and instruction handbook thoroughly to ensure maximum performance from your water softener. If you should experience any difficulty with your water softener, please refer to the problem solving checklist at the back of this handbook. This will help to prevent unnecessary callouts. For service, support or technical advice please call our service desk on Please retain this handbook for future reference

2

3 Identifying major parts of your water softener 1 Control Valve Cover and Electronic Faceplate 1 2 Salt Lid 3 Salt Cabinet 4 Water Softener Valve and Motor 2 5 Brine Well and Cover 6 Overflow Connection 4 7 Rim Note Serial Number is required for registration 3 of warranty (located under salt lid). Please Remember Only use tablet or pellet salt in your softener! 2 Installation of Tapworks Softener models Ultra 9, AD11 & AD 15

4 Installation of Tapworks Softener models Ultra 9, AD11 & AD 15 3 Identifying major parts of your water softener (cont) Description Quantity Easy Install Tees 1pair G1038 (incorporates check valve) By pass set (3 valves) 1 set B505 (1) B534 (2) 15mm reducer (if required) Inlet/Outlet Hoses Hose Gaskets Adaptor Elbows (with prefitted adaptor O rings) Adaptor Clips 1pair Silicone Grease 1 n/a Drain & Overflow Tubing Overflow Elbow Overflow Grommet Drain & Overflow hose clips Transformer Hard Water Test Kit Spares-Adaptor O Rings Please Remember Only use tablet or pellet salt in your softener!

5 Installation of your water softener (cont) PLANNING AND SITING THE INSTALLATION The installation of a water softener is relatively easy, but we recommend that this work is undertaken by a plumber or an experienced DIY handyman. Where possible the water softener should be sited close to the rising main, allowing for any required hard water draw off points, i.e. drinking tap and outside tap. A 22mm installation kit is included with the water softener. Use the 15mm reducers for 15mm pipework. Keep the drain run as short as possible and allow for ease of service and salt access. If installed next to a boiler or hot water cylinder you may have to protect against condensation. When siting the softener please place on a sound base and consider space for accessing the unit for servicing etc. Sufficient space should be left behind the unit to allow easy access for repairs and cleaning. A minimum of 3 space must be left above thevalve cover lid.check local plumbing and electrical regulations and by-laws. The installation must conform to them. FREEZING The installation of all water fittings should be in accordance with local water bylaws and the water softener, and all associated pipework, must be protected against freezing. Take special care where the drain runs outside. Freezing will prevent recharge and cause overflowing. LEAD PIPEWORK Where lead pipework exists downstream of the proposed location of the water softener, we advise you ask the local water authority for advice on the replacement of lead pipework. Grants may be available. Homes built since 1976 will not have lead pipework. ELECTRICAL REQUIREMENTS The water softener requires a 240 volt 50 Hz electrical supply taken off a power supply not a lighting circuit. Power is supplied via a 24 volt 50 Hz transformer. HARDWATER TAP Fitting a separate hard water drinking water tap is currently recommended by the UK Dept of Health,WRAS and the UKWTA. Fitment of separate hard water drinking tap is not required by regulation, except in exceptionally hard water areas (above 400mg/l) where the Sodium content of the treated water (increased due to the softening process) exceeds the level laid down in the Water Supply (Water Quality) Regulations If in doubt please seek advice. Please Remember Only use tablet or pellet salt in your softener! PRESSURE Low or high pressure could lead to damage or non-operation of the water softener. If the daytime pressure exceeds 4.76 BAR (70 psi) a pressure- reducing valve should be fitted. If daytime pressure is less than 1.7 BAR (25 psi) a pressure pump is required. Note: Night-time pressure will be much higher than daytime. FLOW RATES The water flow must be at least 1 litre per minute for the water softener to operate as originally designed. Maximum flow is 53 litres per minute (peak). PLUMBING COMPONENTS NEEDED The installation kit provides the basic plumbing components but additional piping and connectors (capillary and/or compression copper fittings) should be used as required. WARNING: FAILURE TO MEET THE FOLLOWING REQUIREMENTS CAN CAUSE DAMAGE TO THE WATER SOFTENER, OR RESTRICT ITS OPERATION. 4 Installation of Tapworks Softener models Ultra 9, AD11 & AD 15

6 Installation of Tapworks Softener models Ultra 9, AD11 & AD 15 5 Installation of your water softener (cont) SPECIFICATION REQUIREMENTS Maximum water temperature 49 C (120 F) Maximum daytime working pressure 4.76 BAR (70 psi) Minimum working pressure 1.7 BAR (25 psi) Minimum system flow 0.06m 3 /hr Maximum system flow 3.18m 3 /hr If a pressure-reducing valve is required this may be ordered from Tapworks: Quote Part No for 1/2 or 15mm pipework Quote Part No for 3/4 or 22mm pipework UNVENTED OR COMBINATION SYSTEMS The water softener and installation kit is compatible with unvented or combination systems. All connections are included for the by-pass (two 15mm reducers are included if required). DRAIN HOSE With a recommended pressure of 3 BAR, the maximum drain run is 3m with a constant fall before entering an air gap. The maximum height above the softener should be no more than 2m. CENTRAL HEATING SYSTEMS Central heating systems should always be treated with a proprietary corrosion inhibitor regardless of being filled with softened or hard water. Systems containing aluminium should always be filled with hard water unless instructed otherwise by the manufacturer. A Pressure Reducing Valve (if required) B Bypass Valve C Inlet Valve D Outlet Valve E Inlet tee incorporating check valve Please Remember Only use tablet or pellet salt in your softener! B D E C A

7 Step-by-step guide to plumbing the softener Note: If you need to remove the valve cover for ease of installation simply release the two catches behind the valve cover and tilt top end towards you slowly, taking care not to pull off the wire connections. Please note that the valve cover is connected to the valve motor, so cannot be removed fully. PLUMBING Turn off the water supply at the incoming main and begin plumbing as per the installation instructions on page 5. FIT THE BYPASS KIT Cut off the rising main and install the inlet tee with check valve using 15mm reducer if required. Next, plumb the bypass, 15mm reducer (if required) Inlet open From mains Valve Service Position Inlet tee incorporating check valve To water softener inlet Bypass closed From water softener outlet 15mm reducer (if required) Outlet open To system inlet and outlet valves and outlet tee, using 15mm reducer if required, so that the water supply can be turned back on. Use the threaded valves for the inlet and outlet and the compression valve for the bypass. Before turning the water back on, make sure the bypass is open and the inlet and outlet valves are closed. This will allow water to pass directly to the household system without it diverting to the water softener. See Valve Hard Water Bypass poition diagram below. (The use of the plastic plumbing fittings with copper pipe may affect the electrical earthing or bonding of the copper pipe. If in doubt, we advise that you contact a qualified electrician for advice). To bypass softener, ensure bypass is open (horizontal) as per right hand diagram below. 15mm reducer (if required) Inlet closed From mains Hard Water Bypass Position Inlet tee incorporating check valve To water softener inlet Bypass open From water softener outlet 15mm reducer (if required) Outlet closed To system Please Remember Only use tablet or pellet salt in your softener! 6 Installation of Tapworks Softener models Ultra 9, AD11 & AD 15

8 Installation of Tapworks Softener models Ultra 9, AD11 & AD 15 7 Step-by-step guide to plumbing the softener (cont) FIT THE INLET AND OUTLET ADAPTOR ELBOWS Remove the plastic plug from the outlet port on the water softener valve, if present. Adaptor elbows are pre-fitted with a single O ring to the outer groove. Push the adaptors into the valve inlet as far as they will go. Lightly lubricate using the silicone grease provided. Note: Do not use petroleum jelly or oil based lubricants Note: See diagram opposite for O Ring location (pre-fitted) Spare O rings are supplied only if required. O Ring Inlet Turbine Located Inside Outlet O Ring Please RememberOnly use tablet or pellet salt in your softener!

9 Step-by-step guide to plumbing the softener (cont) SECURE THE ADAPTOR ELBOW Snap the two large adaptor clips into place,from the top down (see top illustration opposite). Be sure they snap firmly into place so that the adaptors will not pull out. Pull on the adaptors to ensure a tight fit has been achieved. INLET AND OUTLET CONNECTIONS (For unvented or direct systems refer to page 5). Use the connecting hoses provided with the elbow unions to make the inlet and outlet connections. Fit the hose gaskets into the ends of the inlet/outlet hoses. DRAIN OUTLET/OVERFLOW CONNECTION Insert the rubber grommet into the overflow socket situated 2/3 of the way up the rear of the water softener cabinet. Only insert the overflow adaptor using the silicone grease provided once the grommet is secure. Cut two lengths of hose as required to make the drain and overflow connections. Fit one length of hose onto the overflow adaptor and one length onto the drain line adaptor. Turn the drain line adaptor so that a straight connection can be made. The drain hose and overflow hose must be secured with the supplied metal clamps (see bottom illustration opposite). Pass the overflow hose through a hole in an outside wall so that its end can be seen. The drain hose may be connected directly into an open drain or via the waste outlet similar to a washing machine. The drain and overflow must be kept straight and not kinked. On some tight fitting installations it may be a benefit to make all connections up before inserting the elbow into the valve ports. Please Remember Only use tablet or pellet salt in your softener! 8 Installation of Tapworks Softener models Ultra 9, AD11 & AD 15

10 Installation of Tapworks Softener models Ultra 9, AD11 & AD 15 9 Step-by-step guide to plumbing the softener (cont) ELECTRICAL INSTALLATION The water softener works on a 24 volt, 50Hz electric power supply. You must plug the transformer into a 240 volt outlet only. Be sure that the electrical outlet you plug the transformer into is inside, as the transformer is not designed for outdoor use. To connect the transformer to the controller board, push the female end plugs on to the male connectors as indicated below. The two flat ends of the female connectors should face each other to allow for an easy connection. Should the faceplate fail to display or indicate an error code, please check that the connections are as per the diagram below, you will need to remove the valve cover to do this. Please Remember Only use tablet or pellet salt in your softener!

11 Programming the Ultra 9 Faceplate If you should experience any difficulty with your water softener, please refer to the problem solving checklist at the back of this handbook. This will help to prevent unnecessary cost and inconvenience. Programming the Ultra 9 Faceplate For service, support or technical advice please call our service desk on

12 Programming the Ultra 9 Faceplate Setting up Your water softener has an advanced volume controlled system which allows you to achieve significant salt and water savings during recharge. Your softener features: a) An LCD display and user friendly buttons. b) An extended power back up (48 hours). The memory retains all settings for extended periods during any power loss and beyond that time only the time needs resetting. c) Recharge is based on patterns established for volumes of water used, giving you the maximum conservation of water and salt usage. Note: To alter settings during normal operation press SET until desired function is reached. 11 Please Remember Only use tablet or pellet salt in your softener!

13 Programming When the transformer is first plugged in, the display will flash 12.00am. Note: Each time you press a button on the fascia panel display, a beeper sounds. One beep signals that a change is accepted. If the beeper sounds continually then a different button is required to affect the operation. SET THE PRESENT TIME The display will continue to flash and the time can be advanced or moved backwards using the s or t buttons. Holding down the buttons advances the time at a faster rate. If the time requires changing during normal operation, press the SET button once. The display will flash and indicate present time. You may use the s or t buttons as described above to alter the time. Once the required time is displayed the time may be set by pushing the SET button once more. SET THE WATER HARDNESS CALCULATION The display will flash 25 hardness (this is a pre-set factory setting). Hardness varies from one location to another. Use the kit provided to determine your water hardness in ppm. If necessary change to the unit setting indicated. 25 HARDNESS WATER HARDNESS ppm Unit Setting (170) 10 (190) 11 (200) 12 (220) 13 (240) 14 (255) 15 (270) 16 (290) 17 (300) 18 (325) 19 (340) 20 (360) 21 (380) 22 (400) 23 (420) 24 (440) 25 (460) 30 (480) 30 (500) 35 Programming the Ultra 9 Faceplate Please Remember Only use tablet or pellet salt in your softener! 12

14 Programming the Ultra 9 Faceplate Programming (cont) To increase or decrease the displayed number to your required setting use the s or t buttons. Once the required setting is displayed it may be set by pushing the SET button once more. SETTING ADDITIONAL FEATURES SET THE RECHARGE TIME Hold down the SET button for 3 seconds, 02:00AM recharge time will appear on the screen. Note: 2.00AM is chosen because any household water used during recharge will be replaced with hard water. Consequently a time is required when very little, if any, water will be used. To select a different recharge time use the s or t buttons, to adjust one hour at a time. Once the required setting is displayed it may be set by pressing the SET button once more. Note: Recharge will last for approximately 1 hour. 02:00 RECHARGE TIME For maximum efficiency, we recommend the factory setting DY is maintained. This ensures the unit will automatically control all recharges with intervals based on water usage. If required, press s to set a maximum time in days between recharges. Each press of the s button advances 1 day. When set, the unit will recharge after the set number of days since the last recharge, irrespective of water usage. Press the SET button again, and OFF-HEAVY BKWASH will be shown on the display. For operation with this unit the heavy back wash must remain OFF. If this facility is ON, press the t button to change. Press the SET button to continue. 97 recharge will appear on the screen. For operation with this unit, the 97 recharge feature must remain OFF. If this facility is ON, press the t button to change. Press the SET button to complete the programming procedure. RECHARGE OFF HEAVY BKWASH 97 RECHARGE 13 Please Remember Only use tablet or pellet salt in your softener!

15 User information The unit can be programmed to recharge at the next pre-programmed time, regardless of its remaining capacity. This is particularly beneficial to ensure a sufficient softened water supply for an unexpected heavy water usage the next day. Simply press the TOUCH/HOLD button once. Recharge tonight will flash on the display, indicating a recharge will occur at the pre-programmed recharge time. This completes the instruction. Should you wish to cancel this recharge, press the TOUCH/HOLD button once and immediately release. The display will return to the to the time display. TO RECHARGE NOW Alternatively a manual recharge can be initiated at any time. Simply press the TOUCH/HOLD button and hold it down for approximately 3 seconds, until a beep sounds. Recharge will flash on the display. The process will take a few minutes to begin and lasts approximately 1 hour. It cannot be cancelled once started. 12:00 RECHARGE TONIGHT WATER MANAGEMENT SYSTEM 20 % CAPACITY 12:00 RECHARGE NOW 20 % WATER MANAGEMENT SYSTEM CAPACITY Use as little water as possible during this time period as hard water will bypass the water softener. Once a recharge is complete, the recharge now display will disappear. The present time will be displayed. Note: The unit will automatically flash recharge tonight once the computer calculates that a recharge is required. This is information only no action is required. Once recharge begins, a flashing recharge replaces the flashing recharge tonight. Programming the Ultra 9 Faceplate Please Remember Only use tablet or pellet salt in your softener! 14

16 Programming the Ultra 9 Faceplate User information (cont) HOUSEHOLD WATER USAGE INFORMATION To access these features, press the DATA button, until desired information is displayed. The information is shown below the clock. SOFTENED WATER CAPACITY REMAINING (%) After the unit has recharged, its capacity to produce softened water will be 100%. This capacity will decrease as you use the soft water. This is a useful feature as it allows you to see at a glance the status of your machine. If you you are about to have an influx of guests, then check the status of the unit. If it is below 50% it is advisable to initiate an immediate recharge or, set the machine to recharge that night. MEASURING THE FLOW RATE This display will show the water flow rate through the water softener in litres per minute. If the reading is zero, open a tap connected to the softened water supply to achieve a reading. If the reading is still zero check that the inlet, outlet and bypass valves are set as per diagram on page 6. 12:00 RECHARGE TONIGHT WATER MANAGEMENT SYSTEM 20 % CAPACITY 23:00 WATER MANAGEMENT SYSTEM.0 % FLOW RATE LITRES TODAY Each day, beginning at midnight, the timer keeps a running count of the total amount of water passing through the softener. AVERAGE DAILY LITRES If desired, return to the normal screen by pressing the data button repeatedly. The figure displayed is the average amount of water used by the household each day, over the past 7 day period. WATER MANAGEMENT SYSTEM 173 LITRES TODAY PM 12:22 RECHARGE TONIGHT WATER MANAGEMENT SYSTEM 19 x 10 AVG DAILY LITRES 15 Please Remember Only use tablet or pellet salt in your softener!

17 User information (cont) POWER CUTS If the electrical power to the water softener is interrupted, the time display will be blank, but the memory built into the electronics will keep the correct time for up to 48 hours. The water softener will not recharge but will pass softened water. In the case of a power cut your demand for water will be less as most appliances will not work and so a recharge should not be necessary. When electrical power is returned,one of two things will happen: 1 Power off up to 48 hours The display returns and is steady. No operation is necessary. 2 Power off over 48 hours The display returns and flashes. Only the time requires re-setting. The hardness and recharge time will not have been lost as they are stored. Even if the time is incorrect after a certain period, the water softener will continue to work but will recharge at what it believes the time to be. Programming the Ultra 9 Faceplate Please Remember Only use tablet or pellet salt in your softener! 16

18 Programming the Ultra 9 Faceplate Diagnostic data transfer Tapworks Water Softeners come fitted with our unique diagnostic data transfer system. Our Automated Service Evaluation System enables your water softener to talk directly to the Service Centre and communicate data which otherwise might only be accessed by a site visit to your home. The data received is reviewed by a technician and if there is a problem it may be possible to correct it by telephone. If a service call is necessary, the engineer will be likely to know in advance what parts and repairs are required. DIAGNOSTIC DATA TRANSFER Can provide you with information on the efficiency and performance of your water softener. Can save you the cost and inconvenience of an unnecessary call-out. Can save time and money in the event of a call-out. USING THE DIAGNOSTIC DATA TRANSFER You will need a telephone. Dial the Service Centre dedicated telephone number When connected, the Service Centre will ask you to follow a simple procedure. Hold the telephone mouthpiece about 1 from the symbol on the faceplate below the screen. (see illustration below). Press the telephone button. CALL will appear on screen. Press the telephone button again. The unit will beep for approximately 30 seconds When the beeping stops finish your call. Your call will then be processed by the Service Centre. Don t forget to leave your details if you expect a reply! 17 Please Remember Only use tablet or pellet salt in your softener!

19 Finishing installation Your unit should now be fully plumbed and ready to use. NOTES TO THE INSTALLER BEFORE YOU LEAVE 1 Having programmed your unit you will wish to ensure that it is functioning properly before you leave the site. 2 Our Service Department will offer you advice. If you have any queries do not hesitate to call us. 3 Open the inlet and outlet valve and close the bypass as indicated in the diagram (page 6). Check that all the plumbing connections are secure and that there are no leaks. 4 Check that the time of day is correct. 5 Initiate a recharge Hold down the TOUCH/HOLD button for about 3 seconds until RECHARGE flashes in the display. After a few minutes a small amount of water will enter the salt cabinet. This process will take approximately 4-8 minutes. FILL WITH SALT 6 Once the water has run to drain,fill the cabinet with salt and check your drain connections. You will require a 25kg bag of Pellet salt or Tablet salt. DO NOT use granular salt. Make sure that the brine well cover is in place and secure as salt must not be allowed to enter the brine well. Do not fill salt above the overflow. (See unit explosion diagram page 2). 7 The whole recharge procedure will take approximately 1 hour. Once complete softened water will gradually replace the hard water in the storage tank over a period of normally 7 days. However, this can take longer in larger houses. 8 Advise the customer that any water fed from the storage tank will not be softened immediately. Any water drawn directly from the softener following recharge will be soft. 9 Ensure that the customer is left with all literature relating to the unit. 10 Return the Guarantee Registration Card to Tapworks. IMPORTANT TAPWORKS WATER SOFTENERS HAVE 12 MONTHS PARTS & LABOUR WARRANTY. YOU CAN EXTEND THIS TO 2 YEARS BY RETURNING THE GUARANTEE REGISTRATION CARD. WE WILL SEND YOU (WITHIN 28 DAYS)YOUR WARRANTY CERTIFICATE DETAILING YOUR 2 YEAR GUARANTEE. If you are a regular user of water softeners you will benefit from joining Team Tapworks. Call for details. Thank you for choosing Tapworks. Programming the Ultra 9 Faceplate Please Remember Only use tablet or pellet salt in your softener! 18

20

21 Programming the AD11 & AD15 Faceplates If you should experience any difficulty with your water softener, please refer to the problem solving checklist at the back of this handbook. This will help to prevent unnecessary cost and inconvenience. For service, support or technical advice please call our service desk on Programming the AD11 & AD15 Faceplates

22 Programming the AD11 & AD15 Faceplates Setting up Your water softener has an advanced volume controlled system, which allows you to achieve significant salt and water savings during recharge: Your unit features: a) An LCD display and user friendly buttons. b) An extended power back up (48 hours). The memory retains all settings for extended periods during any power loss and beyond that only the time needs resetting. c) Recharge based on patterns established for volumes of water used, giving you the maximum conservation of water and salt usage. Note: To alter settings during normal operation press SELECT until desired function is reached. 21 Please Remember Only use tablet or pellet salt in your softener!

23 Programming When the transformer is first plugged in, the display will flash 12.00am. Note: Each time you press a button on the fascia panel display, a beeper sounds. One beep signals that a change is accepted. If the beeper sounds continually then a different button is required to affect the operation. SET THE PRESENT TIME The display will continue to flash and the time can be advanced or moved backwards using the s or t buttons. Holding down the buttons advances the time at a faster rate. 12:00 AM PRESENT TIME If the time requires resetting during normal operation, press the SELECT button once. The display will flash and indicate present time. You may use the s or t buttons as described above to alter the time. Once the required time is displayed the time may be set by pushing the SELECT button once more. SET THE WATER HARDNESS CALCULATION The display will flash 25 hardness (this is a pre-set factory setting). Hardness varies from one location to another. Use the kit provided to determine your water hardness in ppm. If necessary change to the unit setting indicated. WATER HARDNESS ppm Unit Setting (170) 10 (190) 11 (200) 12 (220) 13 (240) 14 (255) 15 (270) 16 (290) 17 (300) 18 (325) 19 (340) 20 (360) 21 (380) 22 (400) 23 (420) 24 (440) 25 (460) 30 (480) 30 (500) 35 Programming the AD11 & AD15 Faceplates Please Remember Only use tablet or pellet salt in your softener! 22

24 Programming the AD11 & AD15 Faceplates Programming To increase or decrease the displayed number to your required setting use the s or t buttons. Once the required setting is displayed it may be set by pushing the SELECT button once more. SET THE RECHARGE TIME The display will flash recharge time, which is the pre-set factory setting. If you wish to change this time then proceed as follows: (if not, press SELECT and proceed to the next section). Note: 2.00am is chosen because any household water used during recharge will be replaced with hard water. Consequently a time is required when very little, if any, water will be used. To select a different recharge time use the s or t buttons, to adjust one hour at a time. Once the required setting is displayed it may be set by pressing the SELECT button once more. Recharge will last for approximately 1 hour. 15 HARDNESS 2:00 AM PRESENT TIME 23 Please Remember Only use tablet or pellet salt in your softener!

25 User information TO RECHARGE TONIGHT The unit can be programmed to recharge at the next pre-programmed time, regardless of its remaining capacity. This is particularly beneficial to ensure a sufficient softened water supply for an expected heavy water usage the next day. Simply press the TOUCH/HOLD button once. Recharge tonight will flash on the display.to cancel recharge tonight, press the TOUCH/HOLD button once and immediately release. The display will return to the time display. TO RECHARGE NOW Alternatively, a manual recharge can be initiated at any time. Simply press the TOUCH/HOLD button and hold it down for approximately 3 seconds, until a beep sounds.recharge will flash on the display. The process will take a few minutes to begin and last approximately 1 hour. It cannot be cancelled once started. 9:10 AM RECHARGE TONIGHT 1 1:00 AM RECHARGE NOTE: The unit will automatically flash recharge tonight once the computer calculates that a recharge is required. This is for information only no action is required. At the next programmed recharge time the cycle will automatically begin. Once a recharge is initiated a flashing recharge replaces the flashing recharge tonight. Programming the AD11 & AD15 Faceplates Use as little water as possible during this time period as hard water will bypass the water softener. Once the recharge is complete the recharge display will disappear. Please Remember Only use tablet or pellet salt in your softener! 24

26 Programming the AD11 & AD15 Faceplates User information (cont) POWER CUTS If the electrical power to the water softener is interrupted, the time display will be blank,but the memory built into the electronics will keep the correct time for up to 48 hours. The water softener will not recharge but will pass softened water. In the case of a power cut your demand for water will be less as most appliances will not work and so a recharge should not be necessary. When electrical power is returned, one of two things will happen: 1 Power off up to 48 hours The display returns and is steady. No operation is necessary. 2 Power off over 48 hours The display returns and flashes. Only the time requires re-setting. The hardness and recharge time will not have been lost as they are stored. Even if the time is incorrect, the water softener will continue to work but will recharge at what it believes the time to be. Re-set the time as described in the programming section (see page 22). Should an error code appear Check electrical connections are as per configuration on page 9. a Unplug transformer. b Check direct connections. c Replug transformer. d Wait for 6 minutes.if the error code is rectified,the error code will not re-appear. NOTE: The softener may recharge immediately following a cleared error code. BUILDING A HISTORY Because it has no historical data to base its logic on, your water softener will recharge quite frequently when first used to ensure continuous softened water. Within a few months it will settle into a more regular pattern. SALT USAGE Because your Automatic Demand water softener uses proportional brining, more frequent recharges are not at the expense of high salt usage. However, if you are a household with low water usage you will find after a few months that your water softener will become increasingly efficient, as it adapts to suit your water usage. ERRO1 LARGE INFLUXES OF GUESTS If you have people to stay and use more water than normal, you will find that your Automatic Demand water softener recharges more frequently. As your household water usage returns to normal, so too will the recharge frequency. 25 Please Remember Only use tablet or pellet salt in your softener!

27 Diagnostic data transfer Tapworks water softeners come fitted with our unique diagnostic data transfer system. Our Automated Service Evaluation System enables your water softener to talk directly to the Service Centre and communicate data which otherwise might only be accessed by a site visit to your home. The data received is reviewed by a technician and if there is a problem it may be possible to correct it by telephone. If a service call is necessary, the engineer will be likely to know in advance what parts and repairs are required. DIAGNOSTIC DATA TRANSFER Can provide you with information on the efficiency and performance of your water softener. Can save you the cost and inconvenience of an unnecessary call-out. Can save time and money in the event of a call-out. USING THE DIAGNOSTIC DATA TRANSFER You will need a telephone. Dial the Service Centre dedicated telephone number When connected, the Service Centre will ask you to follow a simple procedure. Hold the telephone mouthpiece about 1 from the symbol on the faceplate below the screen. (see illustration below). Simultaneously press the UP and DOWN buttons. A constant beeping pattern is emitted. Release the buttons,the data message will continue to transmit for about 20 seconds. When the beeping stops finish your call. Your call will then be processed by the Service Centre. Don t forget to leave your details if you expect a reply! Programming the AD11 & AD15 Faceplates Please Remember Only use tablet or pellet salt in your softener! 26

28 Programming the AD11 & AD15 Faceplates Finishing installation Your unit should now be fully plumbed and ready to use. NOTES TO THE INSTALLER BEFORE YOU LEAVE 1 Having programmed your unit you will wish to ensure that the unit is functioning properly before you leave the site. 2 Our Service Department will offer you advice. If you have any queries do not hesitate to call us. 3 Open the inlet and outlet valve and close the bypass as indicated in the diagram (page 6). Check that all the plumbing connections are secure and that there are no leaks. 4 Check that the time of day is correct. 5 Initiate a recharge Hold down the TOUCH/HOLD button for about 3 seconds until RECHARGE flashes in the display. After a few minutes a small amount of water will enter the salt cabinet. This process will take approximately 4-8 minutes. FILL WITH SALT 6 Once the water has run to drain,fill the cabinet with salt and check your drain connections. You will require a 25kg bag of Pellet salt or Tablet salt. DO NOT use granular salt. Make sure that the brine well cover is in place and secure as salt must not be allowed to enter the brine well. Do not fill salt above the overflow. (See unit explosion diagram page 2). 7 The whole recharge procedure will take approximately 1 hour. Once complete softened water will gradually replace the hard water in the storage tank over a period of normally 7 days. However, this can take longer in larger houses. 8 Advise the customer that any water fed from the storage tank will not be softened immediately. Any water drawn directly from the softener following recharge will be soft. 9 Ensure that the customer is left with all literature relating to the unit. 10 Return the Guarantee Registration Card to Tapworks. IMPORTANT TAPWORKS WATER SOFTENERS HAVE 12 MONTHS PARTS & LABOUR WARRANTY. YOU CAN EXTEND THIS TO 2 YEARS BY RETURNING THE GUARANTEE REGISTRATION CARD. WE WILL SEND YOU (WITHIN 28 DAYS) YOUR WARRANTY CERTIFICATE DETAILING YOUR 2 YEAR GUARANTEE. If you are a regular user of water softeners you will benefit from joining Team Tapworks. Call for details. Thank you for choosing Tapworks. 27 Please Remember Only use tablet or pellet salt in your softener!

29 Problem solving Problem solving Tapworks Softener Models Ultra 9, AD11 & AD15 For service, support or technical advice please call our service desk on

30 Problem solving Problem solving (cont) If you are experiencing poor water flow, please check all plumbing first, as it is extremely rare for a softener to cause flow rate problems. Save money by ensuring an engineer is not called out unnecessarily. However, if the solution to the problem is not successful, please call for service and advise us what you have tried. Call our Direct Service Line on: Checklist PROBLEM: Hard Water or, Intermittently Hard Water Solution Page No. 1. Is there a minimum of 6 inches of salt in the cabinet? 1. Fill the cabinet with salt Is the bypass valve closed and the inlet and outlet valves open? 2. Close the bypass valve and open the inlet and outlet valves Is the hardness setting correct? 3. Reset the unit setting as per table open the inlet and outlet valves. 12 & 22 Important Notes: If any of the above requires action, add 4 litres of clean water to the salt and initiate a recharge now. PROBLEM: No Water 1. Is the water mains open? 1. Open water mains Are the inlet and outlet valves open? 2. Open the inlet and outlet valves. 6 PROBLEM: Unit recharges at incorrect time of Day 1. Is the present time correct? 1. Reset the present time. 12 & Is the recharge time correct? 2. Reset the recharge time. 13 & Has there been a power cut? PROBLEM: No Recharge occurring or, little or no salt usage 1. Is the water soft? 1. If yes, no action is required. 2. Is the water level in the salt cabinet high? 2. If yes, check the drain line is not frozen or blocked. Initiate. 14 & 24 an immediate recharge. 29 Please Remember Only use tablet or pellet salt in your softener!

31 Problem solving (cont) Checklist PROBLEM: Excessive Salt Usage Solution 1. Check the hardness. 1. Reduce the unit setting if incorrect. 12 & 22 PROBLEM: No Water in Cabinet or Very Low 1. This is quite normal. Unlike conventional water softeners only a 1. No action necessary. a few inches of water is at the bottom of the cabinet. PROBLEM: High Water Level in Cabinet 1. Is the water level in the salt cabinet high? 1. Initiate an immediate recharge. If the problem does not return, 14& 24 there is nothing wrong PROBLEM: Water Running Down the Overflow 1. Is the water level in the salt cabinet high? 1. If yes, bypass the water softener and call for service. 6 PROBLEM: Water Running Down the Drain Line Constantly 1. Is the unit in recharge mode? 1. If yes, wait until it finishes, check the present time and 12 & 22 Page No. Problem solving recharge time settings and adjust if incorrect. 2. Does an error code appear, eg ERR 01? 2. Check all electrical connections are secure. Turn the power off for 9 ten seconds, and then switch back on. PROBLEM: Electronic Faceplate 1. Is the Faceplate blank? 1. Check the power is turned on and all connections are secure 9 2. Is the display stuck on one function? 2. Turn the power off for ten seconds and then switch back on. 3. Does an error code appear, eg ERR 03? 3. Check all connections are secure. Turn the power off for ten 9 seconds, and then switch back on. Please Remember Only use tablet or pellet salt in your softener! 30

32 Problem solving Guarantee, service & general information (cont) All Tapworks Domestic Water Softeners are fully covered by one year parts and labour guarantee against manufacturing defects from the date of purchase. This guarantee does not affect the statutory rights of the consumer. Any faults which are not attributable to the water softener but to faulty installation or operation will be chargeable. The following,which are not attributable to the water softener but to faulty installation or operation, will be chargeable. 1 Water softeners installed where pressure or flow rates are not within the limits stated in the user and installer handbook. 2 Faults arising from misuse or neglect. 3 Failure to replenish salt, or not using tablet/pellet salt. 4 Resetting the programmer in the event of a power failure or incorrect programming. 5 Resetting the programmer when the influent water hardness or the number of people in the household changes. 6 Water softeners not installed in accordance with local regulations. 7 Any fault arising from repairs or alterations to the water softener carried out by anyone other than our own engineers. 8 Water softeners installed outside the mainland counties of England. 9 Faults arising from faulty installation,plumbing or electrical. 10 Any defect or damage occasioned by fire, lightning, explosion, flood, storm, tempest, impact or other extraneous causes. 11 Water softener installed on bore hole,well water or a non-standard installation not covered by the instruction book may be subject to limitations on the warranty provided. 12 Units installed in such a way that access for servicing is restricted. RETURN YOUR REGISTRATION CARD TODAY! TO BENEFIT FROM YOUR FREE 2 YEAR GUARANTEE 31 Please Remember Only use tablet or pellet salt in your softener!

33 Guarantee, service & general information (cont) General information SALT Salt is used as the cleansing agent for your water softener s resin bed. The salt cabinet will need to be refilled from time to time. It is essential that approximately 6 inches of salt is maintained as a minimum to ensure operating efficiency. Failure to replenish salt will prevent the unit from cleansing itself on its recharge cycle and consequently it will be unable to soften water. Pour the salt slowly into the cabinet. Ensure that the brine well cap is secure, as no salt should be allowed to enter here. DO NOT use granular salt. ONLY USE TABLET SALT OR PELLET SALT. Your local water softener stockist will stock salt. HOLIDAYS We would recommend that you by-pass your water softener if you are away from your home for long periods of time. NOTE: During the cleaning process salt does not enter the water supply. Salt is rinsed to drain. CLEANING Your unit may be cleaned with a damp cloth and detergent. Do not use bleaches, solvents or spirits as this may cause damage. WATER LEVEL The water level will vary. Generally there will be no more than two inches of water in the cabinet. During recharge this will increase. Water may normally be visible only when the salt level is very low. PERFORMANCE CHECK-UP To ensure the efficient operation of your softener, Tapworks recommends regular servicing. Please call to discuss your service options. Problem solving RETURN YOUR REGISTRATION CARD TODAY! TO BENEFIT FROM YOUR FREE 2 YEAR GUARANTEE Please Remember Only use tablet or pellet salt in your softener! 32

34 Problem solving General information THE USE OF SOFTENED WATER WASHING MACHINES You will need much less soap powder. In most washes one tablespoon will be sufficient. Too much lather and clothes will not rinse properly. DISHWASHERS If your dishwasher is on a softened water supply, you will no longer need to fill your unit with salt. The salt was used to soften the water in the dishwasher. STEAM IRONS/CAR BATTERIES Only used distilled or deionised water,not softened water. Always follow manufacturers instructions. COPPER STAINING This will be caused by new pipework and should disappear after a short time. Simply wipe away any deposit. If this persists poor earthing may be allowing electrolytic corrosion. Contact an electrical engineer. IS MY WATER SOFT? Test the water hardness from the softened supply using the test kit supplied. Your water should change the colour of the test with one drop of solution. If your unit has been installed for a short period of time it may be 2-3 weeks before the softened water completely replaces the hard water in your storage tank. HARD WATER One household tap and any garden taps should be left on a hard water supply. Softened water contains a small amount of sodium. In four pints of softened water the sodium content is about the same as in1/4 pint of milk. It is recommended not to use softened water with baby formula or for people on low-sodium diets. If you are concerned about the quality of your drinking water supply ask your local stockist about the benefits of a Tapworks Drinking Water System. CLEANING SINKS, BATHS AND BASINS You will find that your cleaning chores are reduced, and you will use less cleaning product, as cleaning becomes a quick wipe around. Occasionally spotting may result but this is easily rinsed off and nothing to worry about. 33

35

36 Tapworks, Mill Road, Stokenchurch, Bucks HP14 3TP Direct Service Line: Fax: As part of our policy of ongoing research and development, we reserve the right to alter design and specification without prior notice. Part no: Iss: 03/13

User and Installer Handbook

User and Installer Handbook User and Installer Handbook User and Installer Handbook Tapworks Softener Models Ultra 9, AD11, AD15 & AD15 Infinity User and Installer Handbook Tapworks Softener Models Ultra 9, AD11, AD15 & AD15 Infinity

More information

BWT WS Range Water Softener

BWT WS Range Water Softener WS Cover.pdf 1 02/01/2014 13:29 Fitting and operating instructions EN BWT WS Range Water Softener BWT WS Range /09-2012 BWT UK Limited Changes of technical details are reserved Important notice: Always

More information

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.

More information

OWNER S MANUAL. Deluxe Demand Water Softeners MODEL NOS. 625.348570 625.348590

OWNER S MANUAL. Deluxe Demand Water Softeners MODEL NOS. 625.348570 625.348590 OWNER S MANUAL MODEL NOS. 625.348570 625.348590 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. If you have questions when installing, operating or

More information

Water Tec of Tucson Water Systems

Water Tec of Tucson Water Systems Water Tec of Tucson Water Systems Water Filter Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 1 MAIN COMPONENTS Your water treatment

More information

EcoSoft Water Softener. General Installation Guide

EcoSoft Water Softener. General Installation Guide EcoSoft Water Softener General Installation Guide Planning Our Softener Installation Please observe any local or national regulations concerning the installation of your water softener. Check that there

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

Chill 4 Hole Bath Shower Mixer

Chill 4 Hole Bath Shower Mixer Chill 4 Hole Bath Shower Mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts Contents Page 1. Introduction 02 2. Safety Note

More information

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version MASTER Water Conditioning Corp. Installation and Operation Manual MCA Time Clock Series Residential Softeners February 2011 Version Table of Contents Page No. Topic Description 1 Model # and Packaging

More information

Please read and keep these instructions. Run water through your machine before first use

Please read and keep these instructions. Run water through your machine before first use 47070 Rev 1 24/3/05 2:23 PM Page 1 12 cup filter coffee maker Please read and keep these instructions getting the best from your new coffee maker Safety first Caution must be used when handling hot water,

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual. www.masterwater.

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual. www.masterwater. MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-MBA-15T-30T using the 255/762 Logix Control Valve July 2006 Table of Contents Page No. Topic Description 1 Model

More information

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk 1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance

More information

Water Tec of Tucson Water Systems

Water Tec of Tucson Water Systems Water Tec of Tucson Water Systems Water Softener Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 MAIN COMPONENTS Your water treatment

More information

Owner s Manual. 5600 / 5600 Econominder

Owner s Manual. 5600 / 5600 Econominder 5600 / 5600 Econominder Owner s Manual For questions or in case of emergency, please call your local service technician (preferably the one who installed the system). Product Features, Benefits, & Job

More information

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual. www.masterwater.

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual. www.masterwater. MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-10/13 FILTERS with the 253/742 Logix Control Valve June 2010 Table of Contents Page No. Topic Description 1 Model

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure... 2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting

More information

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List Artisan Thermostatic basin mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts 1. Introduction Thank you for choosing Bristan,

More information

Ambiente Quick Reference Manual

Ambiente Quick Reference Manual Ambiente Quick Reference Manual Schaerer USA Corporation 2900 Orange Avenue, Suite 102 Signal Hill, CA 90755 Phone (888) 989-3004 Fax (562) 989-3075 TABLE OF CONTENTS Machine Overview Page 1 Button Panel

More information

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser FITTING AND OPERATING INSTRUCTIONS FOR DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM General information is given in the users instruction leaflet despatched with the appliance and/or on

More information

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents

More information

Installer & User Guide Effective February 2012

Installer & User Guide Effective February 2012 Model No. MONARCH WATER Installer & User Guide Effective February 2012 The Ultimate Water Softener with the 7 year Guarantee Suppliers to H.M. the Queens Estate at Sandringham Monarch Water Ltd. Halesworth

More information

Design Utility Lever Thermostatic Bath Shower Mixer

Design Utility Lever Thermostatic Bath Shower Mixer Design Utility Lever Thermostatic Bath Shower Mixer Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts General Information Thank

More information

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1 Visage Digital Digital diverter TM Installation guide Visage Digital diverter installation instructions Page 1 Visage Digital diverter Visage Digital concealed with adjustable and fixed head Visage Digital

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet

More information

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting

More information

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit. 1. Description The macerating system of this unit is installed in a case, specifically designed for horizontal outlet spigots. This macerator is manufactured in a factory which is quality certified to

More information

Installation Instructions 4508 4508S

Installation Instructions 4508 4508S SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect

More information

Water Softening. system. GE Appliances. Safety Instructions Proper installation...3. Owner s Manual & Installation Instructions

Water Softening. system. GE Appliances. Safety Instructions Proper installation...3. Owner s Manual & Installation Instructions GE Appliances Water Softening system Safety Instructions Proper installation............3 Installation Instructions Drain connections..........7, 8 Important recommedations....4 Installation instructions......4-6

More information

10/20 COMBINATION UNIT

10/20 COMBINATION UNIT MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual 10/20 COMBINATION UNIT with the 255/742 Logix Control Valve With Vortech October 2006 Table of Contents Page No. Topic

More information

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: This booklet should be left with the user after installation and demonstration Thank you for choosing a quality Redring product

More information

SF15K SF05KSS, SF10KSS

SF15K SF05KSS, SF10KSS Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water

More information

WATER SOFTENER SYSTEMS

WATER SOFTENER SYSTEMS INSTALLATION MANUAL WATER SOFTENER SYSTEMS HousePure Models HP-Soft-2 HP-Soft-4 736-0137 Water, Inc. 1044 East Del Amo Blvd., Carson, CA 90746 www.waterinc.com 310-885-4400 P/N 41482 Rev A 06/04 Table

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler User Guide and Important Warranty Information Suprima 30L - 100L Wall Mounted Fan Assisted Balanced Flue Gas Boiler These instructions are for use with boilers whose serial numbers end C (or higher) only.

More information

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725 Read this manual thoroughly before using and save it for future reference Purchase MAP capsules at Harvey Norman stores nationwide

More information

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER 123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual

More information

2020c WATER SOFTENER. Owner s Manual. visit www.kinetico.co.uk

2020c WATER SOFTENER. Owner s Manual. visit www.kinetico.co.uk 2020c WATER SOFTENER Thank you for choosing Kinetico to improve the quality of your water. You will immediately begin to notice the numerous benefits of having quality water throughout your home and the

More information

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5

More information

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS Applied Energy Products Limited, Morley Way, Peterborough, PE2 9JJ, UK Telephone: +44 (0) 844 372 7761 / Fax: +44 (0) 84 372 7762 Website:

More information

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List Artisan Thermostatic bath shower mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts Contents Page 1. Introduction 03 2. Specification

More information

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4

More information

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular

More information

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,

More information

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction

More information

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL WHAT IS AN ECO AIR COOLER? The ECO AIR COOLER uses evaporative cooling to provide an airflow that is cooler than the

More information

Cadet Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference

Cadet Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference Cadet Tap Range Installation Instructions & User Guide Please keep these instructions for future reference Contents Thank you for choosing Bristan, the UK s leading showers and taps expert. We have designed

More information

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL EVAPORATIVE AIR COOLER INSTRUCTION MANUAL Model: SF-614P Please read this manual thoroughly before using this product. Keep in a safe place for future reference. CONTENTS A. PRODUCT INTRODUCTION 2 B. TECHNICAL

More information

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS 1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding with the installation,

More information

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler User s Operating Instructions & Important Warranty Information Baxi Platinum Combi HE Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house,

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Morco House Riverview Road Beverley HU17 0LD

Morco House Riverview Road Beverley HU17 0LD Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email sales@morcoproducts.co.uk Web www.morcoproducts.co.uk Combi Boilers - Poor Hot Water Delivery Combi

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

San josé OWNER S MANUAL

San josé OWNER S MANUAL San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.

More information

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

NESCAFÉ Solution 8/60 Beverage System. Operations Manual NESCAFÉ Solution 8/60 Beverage System Operations Manual 1 INDEX & WARNINGS INDEX Warnings SECTION: 1 INDEX & WARNINGS SECTION: 2 BASIC PARTS OF THE MACHINE SECTION: 3 LOADING PRODUCTS SECTION: 4 DISPENSING

More information

Thermostatic bar showers. Troubleshooting and maintenance

Thermostatic bar showers. Troubleshooting and maintenance Thermostatic bar showers Troubleshooting and maintenance General Fault Diagnosis Outlet too cold Outlet too hot - Hot water supply must be 10ºC higher than desired mixed outlet for the mixer to operate

More information

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Instruction Sheet 102-140 Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Plant I.D. 001-1024 EFFECTIVE: November

More information

Iron Air Charge 2510-SXT Installation & Start-Up Guide

Iron Air Charge 2510-SXT Installation & Start-Up Guide Iron Air Charge 2510-SXT Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron free water

More information

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Use and Care Manual. Model CPA12KH AIR CONDITIONER Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage

More information

INSTANT HOT WATER RECIRCULATING SYSTEM

INSTANT HOT WATER RECIRCULATING SYSTEM INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure

More information

Dehumidifier Users manual. For Models: DH45S DH65S

Dehumidifier Users manual. For Models: DH45S DH65S Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but

More information

Instruction manual for Firstline FCS12000CH

Instruction manual for Firstline FCS12000CH Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of

More information

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts Colonial Tap Range Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL Electric Kettle Model: SK-1717 INSTRUCTIONS MANUAL Thank you for your purchase. Please read this Instruction Manual thoroughly before use and keep in a safe place for future reference. READ ALL INSTRUCTIONS

More information

For installation guide see reverse of book

For installation guide see reverse of book USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

Line to Refrigerator Ice/Water Dispenser

Line to Refrigerator Ice/Water Dispenser Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon

More information

Fused Spur Time Switch

Fused Spur Time Switch Fused Spur Time Switch Model No. FST24 24 Hour Timer Model No. FST77 7 Day Timer Installation & Operating Instructions 1. General Information Illuminated screen Sets programmes Sets time and date Reset

More information

INSTALLATION INSTRUCTIONS & OWNERS GUIDE

INSTALLATION INSTRUCTIONS & OWNERS GUIDE 316581D-10 JULY 2010 INSTALLATION INSTRUCTIONS & OWNERS GUIDE RHEEM MAINS PRESSURE ELECTRIC HOT WATER HEATERS Congratulations for choosing a Rheem Water Heater It is important that you take a few minutes

More information

service breakdown emergency 3in1 Plan What the SGS Service Plan provides What happens if you have a breakdown Cover provided by the Plan Dear

service breakdown emergency 3in1 Plan What the SGS Service Plan provides What happens if you have a breakdown Cover provided by the Plan Dear 3in1 Plan Dear As per our recent conversation, the SGS Service Plan offers complete peace of mind because for a small premium your central heating equipment will be serviced and covered in the event of

More information

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE! PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE! 1. Read all instructions carefully before using the machine. 2. Do not touch hot surfaces. Use handles or knobs. The lid and

More information

LUCCI AIRFUSION QUEST II CEILING FAN

LUCCI AIRFUSION QUEST II CEILING FAN LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR

More information

Metermatic SE Automatic Water Softener. Operation Manual

Metermatic SE Automatic Water Softener. Operation Manual Metermatic SE Automatic Water Softener Operation Manual Page 7 of this manual contains important maintenance procedures for the continued proper operation of your unit. These MUST be performed regularly

More information

Instruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Instruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function Important Safeguards READ ALL INSTRUCTIONS BEFORE USE. Instruction Manual Automatic Dispensing Hot Water Pot with Reboil Function Image of SP-3015 & SP-3815 SP-3015: 3.0L SP-3815: 3.8L SP-3017: 3.0L (Stainless

More information

Awning Instructions. Full Cassette 1.5m to 6m

Awning Instructions. Full Cassette 1.5m to 6m Awning Instructions Full Cassette 1.5m to 6m English Full Cassette Manual & Electric Instructions Contents Warning 1.5m - 3.5m Awnings 8 x Expansion bolts ** 2 x brackets 1 x Awning 1 x Winder 4.0m -

More information

Installation, Operating and Servicing Instructions. Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM

Installation, Operating and Servicing Instructions. Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM Installation, Operating and Servicing Instructions Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM Please make a note of your product details for future use: Date Purchased: Model Number:

More information

Model 5600SE Downflow

Model 5600SE Downflow Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................

More information

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro

More information

Converse 320. Userfriendly Guide

Converse 320. Userfriendly Guide Converse 0 Userfriendly Guide Return Diversion Minder On Off At a glance IMPORTANT Next Inserts a space in a number when storing numbers in the memory. Clear Used to edit numbers when pre-dialling or when

More information

OR S HANDBOOK Kenco S i n g l e s B r e w e r OPERA

OR S HANDBOOK Kenco S i n g l e s B r e w e r OPERA Kenco Singles Brewer This handbook contains instructions for the Kenco Singles Brewer. Please read the handbook before using the machine. Keep this fold out page open while reading the Operator s Handbook.

More information

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption. THE EXPRESS STILL This still represents the next generation in home distillation equipment. It eliminates the problem of having to spend all day processing a 25 litre wash. Taking 1 hour to heat up, then

More information

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED. CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT

More information

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions Close Coupled & Back To Wall WC Saintaryware Fitting Instructions Before starting any installation project please consider the following: Prior to drilling into walls, check there are no hidden electrical

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

400 Amp Rechargeable Jump Start System RAC-HP082

400 Amp Rechargeable Jump Start System RAC-HP082 400 Amp Rechargeable Jump Start System RAC-HP082 MAINTENANCE Always inspect the tool before use to ensure the cables are in good condition and the clamps are clean and free from corrosion. Keep clean by

More information

Please read this manual carefully before using. Retain for future reference. Automatic Washing Machine User manual

Please read this manual carefully before using. Retain for future reference. Automatic Washing Machine User manual Automatic Washing Machine User manual This manual is for HWMP55-918 HWMP65-918 Please read this manual carefully before using. Retain for future reference. CONTENTS Product Overview 1 Safety Precautions

More information

www.morphyrichards.co.uk

www.morphyrichards.co.uk 43922 rev2:x 06/01/2010 15:06 Page 1 Upon registration with Morphy Richards (UK & ROI only) Register online for your 2 year guarantee. See back of this instruction book for details. (UK and Ireland customers

More information

SHOT BLAST CABINET MODEL NO: CSB20B

SHOT BLAST CABINET MODEL NO: CSB20B SHOT BLAST CABINET MODEL NO: CSB20B PART NO: 7640110 USER INSTRUCTIONS GC0216 INTRODUCTION Thank you for purchasing this CLARKE Shot Blast Cabinet which is designed for professional workshop use. Before

More information

your water pressure explained

your water pressure explained your water pressure explained water networks your responsibility low pressure Our water networks are designed so that a typical home has a plentiful supply of water pressure and flow. There are however

More information

Important Safety Instructions

Important Safety Instructions PR-D7 GB Revision 1 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean

More information

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric

More information

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new Ultrasonic Jewelry/DVD Cleaner make jewelry, dvds and more sparkle like new Table of contents Cautions & Warnings...................................................... 2-4 Location of Controls........................................................

More information

Thermo Top - Troubleshooting Tree

Thermo Top - Troubleshooting Tree Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may

More information

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...

More information

User Manual. Gas fired condensing wall hung boiler. G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw)

User Manual. Gas fired condensing wall hung boiler. G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw) User Manual Gas fired condensing wall hung boiler G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw) CLAS HE R 12 CLAS HE R 18 CLAS HE R 24 Country of destination GB, IE

More information

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions Part No. 130009 Iss. 12 August 2004 Elson www.elsonhotwater.co.uk Open Vented Thermal Store providing mains pressure hot water heated by electricity Installation, Servicing and User's Instructions Read

More information