HVAC Centrifugal Fans Backward Curve DIDW & SISW Forward Curve DIDW Plug Fans
|
|
- Madeleine Cummings
- 7 years ago
- Views:
Transcription
1 HVAC Centrifugal Fans Backward Curve DIDW & SISW Forward Curve DIDW Plug Fans
2 Index TDF Series Centrifugal Fan Backward curved, Double Inlet, Double Width, Belt-Driven Available in 15 metric sizes from 225 mm to mm Bearings and mounting frames available in various design options DTC Series Centrifugal Fan Forward curved, Double Inlet, Various Widths, Belt-Driven Available in 12 imperial sizes from 7-7 to Optional mounting frames or feet DTA Series Centrifugal Fan Forward curved, Double Inlet, Double Width, Belt-Driven Available in 10 imperial sizes from 9-9 to Heavy duty Bearings and mounting frames is standard TAE Series Centrifugal Fan Forward curved, Double Inlet, Double Width, Belt-Driven Available in 17 metric sizes from 160 mm - mm Bearings and mounting frames available in various design options DTK Series Centrifugal Fan Forward curved, Double Inlet, Various Widths and outlet sizes, Direct-Driven Total of 24 sizes, 380v 3 phase external rotor motor Mounting frame design dependant on fan size MTK Series Centrifugal Fan Forward curved, Double Inlet, Various Widths, Direct-Driven Available in 3 sizes, shaft mounted impeller 3 phase 380v and 1 phase 220v motors, Speed controllable
3 Curves (Pa) TDF SERIES TAE SERIES DTC-DTA SERIES (m3/hr) TDF SERIES TAE SERIES DTC-DTA SERIES
4 Introduction DTC, TAE, DTA, Forward curved and TDF Series Backward curved centrifugal fans are used in HVAC systems, filtration systems and other ventilation applications. Product Types TYPE D - LIGHT DUTY The D-Type fan is supported with mounting feet and can be mounted in three different orientations. 3 or 4 spoke bearing support frame. TYPE K - LIGHT DUTY WITH FRAME The K-Type fan is supported with a frame and can be mounted in four different orientations. 3 or 4 spoke bearing support frame. TYPE H - MEDIUM DUTY WITH FRAME The H-Type fan is supported with a medium duty frame and can be mounted in four different orientations. Plummer Block bearing. TYPE G - HEAVY DUTY WITH FRAME The G-Type fan is supported with a heavy duty frame and can be mounted in four different orientations. Plummer Block bearing. TYPE 2D TWIN - LIGHT DUTY TYPE 2K TWIN - LIGHT DUTY WITH FRAME TYPE 2H TWIN - MEDIUM DUTY WITH FRAME
5 Rotation Direction Performance MOTOR POWER The Power on the performance curve is shaft power. Motor power is determined by mechanical efficiency and Safety factor. N = (Ns.K)/ Ns (Shaft power of fan) K (Safety factor) (Mechanical efficiency) SAFETY FACTOR: K=1.25 if Ns < 0.75kW K=1.20 if 0.75kW < Ns < 10kW K=1.15 if Ns < 10kW =0.95 for belt-driven PERFORMANCE OF TWIN FAN For Twin Fan selections, use the data of single fan with following factors: Volume = X2 Power = X2.15 Speed = X1.05 Sound = + 3dB
6 Sound levels The Sound level shown on each curon. Sound Pressure Level A, Free field Lp(A) = Lw(A) - (20logD) - 11 B, Room condition Lp(A) = Lw(A) - (20logD) - 7 where D = Distance of fan (m) Belt tension A proper level of belt tension is required in order to obtain satisfactory belt life. If the belt tension level is too high, then excessive loads will be imposed con the belts and the bearings, and this will reduce the life of both components. If the belt tension level is too low, then the belt will slip. It is important to control the tension of the belts during installation. Small Pulley diameter Force Cr Cr
7 Bearing maintenance be NLG. The bearings are pre-lubricated. Reading performance curves Example Selection duty = 5 500m Pa (total pressure) Pt LwA PW (Total pressure) (Sound power level) (Fan shaft power) (Total efficiency) N (Fan speed) Q Pd (Volume) (Dynamic pressure) V (Outet velocity)
8
9 TDF Double Inlet Backward Curve Centrifugal Fans
10
11 Product overview TDF series of backward curved centrifugal fans are used in a wide variety of applications designed for high efficiency and low noise. Fan sizes available from 200 to, volume flow from 430m 3 /hr to m 3 /hr and total pressure from 120Pa to 2 500Pa. DESIGNATION OF PRODUCTS TDF 355 HM LG ROTATION DIRECTION BEARING TYPE CONSTRUCTION TYPE DIAMETER OF IMPELLER FAN MODEL TECHNICAL SPECIFICATIONS WHEEL: SCROLL: FRAME: BEARINGS: SHAFT: BALANCING: Backward curved, manufactured from high grade steel designed to provide high efficiency and low noise characteristics. Specially designed blades are welded on centre disc and bell entry. Manufactured from high grade galvanised sheetmetal, laser-cut to precision. The scroll plate is joined to side plates by Pittsburgh lock form and weld. Angle iron, coated with polyester paint. Self-aligning ball bearings. Machined from C45 carbon steel to high tolerance levels, and is corrosion resistant coated. All wheels are statically and dynamically balanced to ISO1940 and AMCA 204-G2.5 standard.
12 Bearing types FAN TYPE LIGHT DUTY MEDIUM DUTY Operational limits
13 TDF 200 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
14 TDF 225 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
15 TDF 250 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
16 TDF 280 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
17 TDF 315 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 45% 56% 65% 70.6% 73.9% 72.4% % % LwA 100 db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
18 TDF Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 50% 61% 68% 73.1% 75.7% 73.9% % % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
19 TDF Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] % 62% 70% 74.6% 76.8% 74.8% 65% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
20 TDF 450 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] % 63% 69% 73.5% 77.4% 75.9% 64% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
21 TDF Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 52% 63% 71% 76% 78.7% 76.7% 66% % LwA 110 db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
22 TDF Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] % 63% 71% 76% 78.6% 76.2% 65% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
23 TDF 630 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 52% 63% 72% 77.1% 79.9% 77.1% % % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
24 TDF Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] % 63% 72% 77.1% 80% 77.3% 65% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
25 TDF Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 53% 65% 73% 78.3% 80.8% 78% % % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
26 TDF Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 53% 64% 73% 78.1% 81.1% 78.2% % % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
27 TDF Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] % 64% 72% 77.7% 80.6% 77.9% 66% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
28 OUTLINE DRAWINGS - FAN ONLY TDF-D L G h3 E M t A D C Z t1 h1 h2 UxS d W 5 F B F J K Model A B C D E F G J K L M h1 h2 h3 t t1 W Z ßÊd UXS X X X X18 TDF-K R G Dimensions: mm B L M E M t C A D F1 F Z t1 d F1 W 5 UXS X F1 F H F1 J K Model A B C D E F F1 G H J K L M X R t t1 W Z ßÊd UXS X X X X18
29 TDF-G R G B M L E M t A C D Z t1 F1 F d F1 W 5 UXS X F1 F H F1 J K Model A B C D E F F1 G H J K L M X R t t1 W Z ßÊd UXS X X X X X X X X X X X22
30 TDF-H R G B M L E M t A D C F1 F UXS TDF-2H R G B L E P E M t C Z t1 Z t1 d F1 W 5 X F1 F H F1 J K Model A B C D E F F1 G H J K L M X R t t1 W Z ßÊd UXS X X X X X X X X X X22 A D F1 F d F1 W 5 UXS X F1 F H F1 J V K J Model A B C D E F F1 G H J K L M P X R V t t1 W Z ßÊd UXS X X X X18 1. G3.0º º LG mm 4. TDF400-2H/LG
31 OUTLINE DRAWINGS - COMPLETE FAN ON BASE TDF-D 0º 90º 180º RD H H H L W L W W L LG H H H W L W L L W Model Motor frame size C L W H Weight (Kg) C L W H Weight (Kg) C L W H Weight (Kg) C = centre distance between fan and motor pulley
32 TDF-K 0º 90º 180º RD H H H L W L W W L LG H H H W L W L L W Model Motor C L W H frame size Weight (Kg) C L W H Weight (Kg) C L W H Weight (Kg) C = centre distance between fan and motor pulley
33 TDF-H 0º 90º 180º RD H H H L W L W W L LG H H H Model Motor Frame Size W L W C L W H Weight Weight C L W H (kg) (kg) C L W H C = centre distance between fan and motor pulley L L W Weight (kg)
34 TDF-G 0º 90º 180º H H H RD L W L W W L H H H LG W L W L L W Model Motor C L W H Weight C L W H Weight C L W H Weight frame size (kg) (Kg) (kg) (Kg) (Kg) (kg) C = centre distance between fan and motor pulley
35 DTC Double Inlet Forward Curve Centrifugal Fans (Imperial Sizes)
36
37 Product overview Fan sizes available from 7-7 to 18-18, volume flow from 500m 3 /hr to m 3 /hr and total pressure from 60Pa to 1500Pa DESIGNATION OF PRODUCTS DTC 9-7 2K LG ROTATION DIRECTION CONSTRUCTION TYPE DIAMETER OF IMPELLER FAN MODEL TECHNICAL SPECIFICATIONS WHEEL: SCROLL: FRAME: BEARINGS: SHAFT: BALANCING: Forward curved multi-blade, manufactured from galvanised steel, designed to provide high efficiency and low noise characteristics. Manufactured from high grade galvanised sheetmetal, laser-cut to precision. Galvanised angle steel sections. Self-aligning ball bearings. Machined from C45 carbon steel to high tolerance levels, and is corrosion resistant coated. All wheels are statically and dynamically balanced to ISO1940 and AMCA 204-G4.0 standard. Operational Limits
38 DTC7-7 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
39 DTC8-8 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
40 DTC9-7 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 44% 48% 53% 56.5% 59% 56.1% 46% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
41 DTC9-9 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 32% 40% 46% 53.3% 59.1% 58.3% 48% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
42 DTC10-8 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 41% 48% 53% 58.9% 63% 60.9% 50% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
43 DTC10-10 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 36% 42% 48% 54.1% 59.8% 59.2% 48% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
44 DTC12-9 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 44% 52% 59% 65.8% 64.4% 54% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
45 DTC12-12 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 45% 52% 56% 61.1% 63.4% 58.8% 47% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
46 DTC15-11 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] % 47% 56% 66.9% 67.7% 57% 48% % LwA 100 db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
47 DTC15-15 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 47% 54% 60.8% 63.5% 60.2% 49% 38% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
48 DTC18-13 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 55% 62% 67% 68.5% 61.9% 50% % LwA db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
49 DTC18-18 Air Density: 1.2 kg/m3 Pt [Pa] [%] N [rpm] 40% 52% 61% 66.7% 60.5% 46% % 29% LwA 100 db(a) Pd[Pa] V[m/s] Pw [kw] Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
50 DTC OUTLINE DRAWINGS - FAN ONLY DTC-D
51 DTC-K
52 DTC-2D
53 DTC-2K
54 OUTLINE DRAWINGS - COMPLETE FAN ON BASE DTC-D DTC-K
55 DTC-D
56 DTC-K
57 DTA Double Inlet Fwd Curve HD Centrifugal Fans (Imperial Sizes)
58
59 Product overview Fan sizes available from 9-9 to 30-30, volume flow from 500m 3 /hr to m 3 /hr and total pressure from 60Pa to 1100Pa DESIGNATION OF PRODUCTS DTA 9 2H LG ROTATION DIRECTION CONSTRUCTION TYPE DIAMETER OF IMPELLER FAN MODEL TECHNICAL SPECIFICATIONS WHEEL: SCROLL: FRAME: BEARINGS: SHAFT: BALANCING: Forward curved multi-blade, manufactured from galvanised steel, designed to provide high efficiency and low noise characteristics. Manufactured from high grade sheetmetal, laser-cut to precision, coated with polyester paint. Angle steel sections coated with polyester paint.. Self-aligning ball bearings. Machined from C45 carbon steel to high tolerance levels, and is corrosion resistant coated. All wheels are statically and dynamically balanced to ISO1940 and AMCA 204-G4.0 standard. Operational Limits
60 DTA9-9 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
61 DTA10-10 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
62 DTA12-12 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
63 DTA15-15 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
64 DTA18-18 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
65 DTA20-20 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
66 DTA22-22 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
67 DTA25-25 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
68 DTA28-28 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
69 DTA30-30 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
70 OUTLINE DRAWINGS - FAN ONLY DTA-H
71 DTA-2H
72 DT Impeller
73 OUTLINE DRAWINGS - COMPLETE FAN ON BASE DTA-H
74
75 TAE Double Inlet Forward Curve Centrifugal Fans (Metric Sizes)
76
77 Product overview The TAE Series forward curved centrifugal fans are DWDI. The efficiency of all the fans is guaranteed through specific volume figures at maximum pressure differentials. Excellent performance and minimal noise levels are features of this new fan range. The radial fans are designed for the conveyance of clean air and nonaggressive steam and gases at a temperature range from -30ºC to 80ºC. The fans are suitable for supply or extract applications in commercial, process and industrial HVAC systems. DESIGNATION OF PRODUCTS TAE 225 K LG ROTATION DIRECTION CONSTRUCTION TYPE DIAMETER OF IMPELLER FAN MODEL TECHNICAL SPECIFICATIONS SCROLL: IMPELLER: INLET: BEARINGS: SHAFT: The scroll is manufactured from galvanised sheet steel. Standard holes are located in the side plates to fix mounting frame and mounting feet to allow for easy installation. The impeller of the TAE series is forward multi-bladed in order to obtain maximum efficiency and low noise level. The impeller is manufactured from galvanised steel, the larger diameter impellers are fitted with tie-rods. All impellers are statically and dynamically balanced according to ISO1904 and AMCA 204 G4.0 standards. The aerodynamically shaped inlets are bolted in to guarantee a perfect inlet stream into the impeller. Inlets are made of galvanised sheet metal. The TAE ventillator s bearings are selected to provide maximum life and reliability. For TAE-D/K, sealed deep grooved ball bearings are fitted to the harmonic strut housings. Unavoidable alignment errors in the sheet metal casing are compensated by the spherical outer ring. For type TAE-H, the grooved ball bearings in the rugged cast iron casings are completely sealed. The one-piece bearings have oil nipples for easy lubrication Machined from C45 carbon steel and heat treated. OPERATIONAL LIMITS
78 TAE 160 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
79 TAE 180 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
80 TAE 200 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
81 TAE 225 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
82 TAE 250 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
83 TAE 280 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
84 TAE 315 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
85 TAE 355 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
86 TAE 400 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
87 TAE 450 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
88 TAE 500 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
89 TAE 560 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
90 TAE 630 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
91 TAE 710 Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
92 TAE Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
93 TAE Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
94 TAE Performance shown is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airsteam. Power rating does not include drive losses. All Performance is in NTP.
95 OUTLINE DRAWINGS - FAN ONLY TAE-D NOTE: Overall size tolerance range +/- 3mm. All dimensions in mm.
96 TAE-K NOTE: Overall size tolerance range +/- 3mm. All dimensions in mm.
97 TAE-H 250- NOTE: Overall size tolerance range +/- 3mm. All dimensions in mm.
98 TAE-2D NOTE: Overall size tolerance range +/- 3mm. All dimensions in mm.
99 TAE-2K NOTE: Overall size tolerance range +/- 3mm. All dimensions in mm.
100 TAE-2H NOTE: Overall size tolerance range +/- 3mm. All dimensions in mm.
101 OUTLINE DRAWINGS - FAN ON BASE TAE-D D = Center distance between fan and motor pulley
102 TAE-K D = Center distance between fan and motor pulley
103 TAE-H D = Center distance between fan and motor pulley
104 TAE-H 560- D = Center distance between fan and motor pulley
105 DTK Double Inlet Forward Curve Centrifugal Fans (Direct Driven)
106 DTK Series Centrifugal Fan DESIGNATION OF PRODUCTS DTK 1-2- L CODE DIAMETER IMPELLER TYPE FAN MODEL TECHNICAL SPECIFICATIONS USES: SCROLL: FRAME: BALANCING: Suitable for compact type of central air conditioning systems, filtration units and fan coil units Manufactured from high grade galvanised sheetmetal, laser-cut to precision. Galvanised angle steel sections All wheels are statically and dynamically balanced to ISO1940 and AMCA 204-G4.0 standard. ENVIRONMENT: Clean air free of corrosive and flammable substances. Solid particles must be less than 100mg/m 3. Temperature range between 20ºc - 80ºc
107 DTK - 1 Series Performance t
108 DTK-1 Performance Curve
109 DTK-1 Dimensions
110 DTK-1 Dimensions
111 DTK-11 Performance t
112 DTK-11 Performance Curve
113 DTK-11 Dimensions
114 DTK -11 Dimensions
SECTION 23 34 13. A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.
PART 1 GENERAL SECTION 23 34 13 HVAC FANS 1.01 SUMMARY A. Section Includes: 1. Exhaust fans. 2. Transfer fans. B. Related Documents: 1. Drawings and general provisions of the Contract, including General
More informationICQ Series - square centrifugal
product ICQ Square Centrifugal (TEFC) dimensions mm 280-710 poles & duty 4-8 / up to 4,500 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ
More informationO-I DUBI PLANT FANS Quotation Spec Data & Specifications
TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement
More informationChapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
More informationVXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
More informationFilter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
More informationFor New Technology Network. Steel Manufacturing Machinery Product Guide Book
For New Technology Network R Steel Manufacturing Machinery Product Guide Book Ecological / Economical proposals from NTN NTN products exhibit benefits at various locations. Steel manufacturing equipment
More informationSIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06
SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz
More informationStandard offering (pumps)
MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) info@mdmpumps.co.uk
More informationFAN & BLOWER CENTRIFUGAL FANS
FAN & BLOWR CNTRIFUGAL FANS INTRODUCTION GNRAL PRODUCT RANG FANS BY FANTCH - INTRACTIV PRODUCT SUIT SLCTION PROGRAM PRFORMANC CONSTRUCTION The Fan & Blower range of centrifugal fans is marketed to the
More informationTechnical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
More informationUC-SERIES TIMKEN BALL BEARING HOUSED UNITS
UC-SERIES TIMKEN BALL BEARING HOUSED UNITS 3 TIMKEN BALL BEARING HOUSED UNITS DESIGNED FOR OPTIMIZED PERFORMANCE For more than 110 years, Timken innovations continue to keep the world in motion, including
More informationTechnical Data. 7. Bearing Fits. 7.1 Interference. 7.2 Calculation of interference F B LLLLLLLLL( A-54
Technical Data 7. Bearing Fits 7.1 Interference For rolling s the rings are fixed on the or in the housing so that slip or movement does not occur between the mated surface during operation or under. This
More informationEurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
More informationManual piston sampler...m 11
SAMPLING Manual piston sampler...m 11 Screw sampler...prec 22...PREC 100 Slide sampler...pr 55 Rotative screw sampler...prv Piston sampler...p 11 Sampler on belt conveyor...pba Rotating cup sampler...pgr
More informationINSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional
More informationUNIVERSITY OF ROCHESTER DESIGN STANDARDS OCTOBER 18, 2013
SECTION 233416 - CENTRIFUGAL HVAC FANS PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. Fans shall be dynamically balanced and factory-tested and certified in accordance with applicable AMCA test codes. All
More informationOperataing Manual. Single stage radial Fan. Model MKV/TKV
01.2011 Operataing Manual Single stage radial Fan Model MKV/TKV REITZ-SCHWEIZ VENTILATOR AG Zentweg 11 CH-3006 Bern Telefon +41 (0) 31 / 938 85-85 Telefax +41 (0) 31 / 938 85-86 Internet: www.reitz-schweiz.ch
More informationTube Type Oil Skimmer Comparison
Process Overview- Tube Type Oil Skimmers Oil flows down the face of the skimmer and into a sludge pan that is plumbed to a barrel. Model BG01 & BG34 or 6V Oil Skimmer 1.0 or 3/4 Diameter Collector Tube
More informationDryLin ZLW Belt Drive
Belt Drive +50º 0º DryLin toothed belt drives have been developed for the fast positioning of small loads. The linear units with toothed belt drive are corrosion resistant, light and compact, besides having
More informationPipe Cutting and Beveling Clamshells
Pipe Cutting and Beveling Clamshells Who We Are One Company, Total Support, Complete Solutions For more than a century, Hydratight has provided world-class bolted joint solutions and continues to set international
More informationMachine Design II Prof. K.Gopinath & Prof. M.M.Mayuram. Module 2 - GEARS. Lecture 17 DESIGN OF GEARBOX
Module 2 - GEARS Lecture 17 DESIGN OF GEARBOX Contents 17.1 Commercial gearboxes 17.2 Gearbox design. 17.1 COMMERCIAL GEARBOXES Various commercial gearbox designs are depicted in Fig. 17.1 to 17.10. These
More informationwww.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 26 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
More informationALIGNMENT. Pump and Driver Alignment
ALIGNMENT Pump and Driver Alignment Alignment Subject: Pump and Driver Alignment In the pump business alignment means that the centerline of the pump is aligned with the centerline of the driver. Although
More informationSelf-aligning ball bearings
Self-aligning ball bearings Designs... 470 Basic design... 470 Sealed bearings... 470 Bearings with an extended inner ring... 472 Bearings on sleeves... 473 Self-aligning ball bearing kits... 474 Appropriate
More informationANGLgear. right angle drives Inch and Metric Series. The Original Right Angle Gear Drive Made in the U.S.A.
ANGLgear right angle drives Inch and Metric Series The Original Right Angle Gear Drive Made in the U.S.A. INDEX INTRODUCTION Intro to ANGLgear Inch & Metric Series pg. 2-3 2 Flange Units, Inch Series pg.
More informationSurface Technology. Centrifugal Fan GMD
Centrifugal Fan ATEX classed adapted for paint shops Wide assortment broad area of application Service friendly low maintenance costs Headquarters: Centrifugal Fan Centrifugal Fan is a direct driven industrial
More informationTransformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
More informationRoller Chain Coupling
Roller Chain Coupling Features 1. Simple structure A roller chain coupling consists of one duplex roller chain and two sprockets for a simplex chain. Handling is very simple as both the shafts (driving
More informationINDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single
More informationSUNON SPECIFICATION FOR APPROVAL
SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X25 mm M O D E L : KDE2406PTB2 APPROVED NO : APPROVED BY : (AUTHORZIED) SPEC.NO D600732 ISSUE DATE 10.01.1998 DAWN.
More informationTD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans
IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8
More informationThe conditions below apply to the curves shown on the following pages.
GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves
More informationTFSR & TFSK Roof Fans
Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans TFSR & TFSK Roof Fans With swing-out function 2 I TFSR/TFSK TFSR & TFSK Roof
More informationCRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
More informationSTAR Linear Bushings and Shafts Supplement RE 83 117/2001-08. Linear Motion and Assembly Technologies
STAR Linear Bushings and Shafts Supplement RE 83 117/2001-08 Linear Motion and Assembly Technologies STAR Linear Motion Technology Ball Rail Systems Standard Ball Rail Systems Ball Rail Systems with Aluminum
More informationCharacteristics of Centrifugal Blower and Its Effective Use in High Static Pressure Area
Characteristics of Centrifugal Blower and Its Effective Use in High Static Pressure Area Masayuki TAKAHASHI With small fans, selecting the right fan that most fits the purpose is extremely important from
More informationFume Extraction: Guide to Safely Managing Solder Fumes in the Workplace
Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace Our thanks to OK International for allowing us to reprint the following. Why do we need fume extraction? Today s Electronics workplace
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationLU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions
LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment
More information1300 MAXTRAK SPECIFICATION
CONE CRUSHER Crusher type: Liners: Standard concave: Lubrication: Adjustment: Control: Concave options: 1300 Automax Crusher. Manganese steel alloy mantle and concave. Medium Coarse. Pumped system having
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationPump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
More informationTURBOWENT TULIPAN - rotary chimney cowl Ø150
Picture Function principle rotation direction Wind Chimney draught Description Rotary chimney cowl Turbowent Tulipan is a device, which, in a dynamic way, uses force of the wind to increase chimney draught.
More informationSVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS 426 2.98 16.05
SIGMA PUMPY HRANICE SELF PRIMING PUMPS SVA SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +40 581 661 111, fax: +40 581 60 587 Email: sigmahra@sigmahra.cz 46.98 16.05 Applications
More informationFixed displacement vane pumps
Fixed displacement vane pumps RE 1335/1.5 Replaces: 11.2 1/22 Types PVV and PVQ Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 Doppelpumpe_d_ Double
More informationRPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS 426 2.98 23.01
SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS RPT SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +4 581 661 111, fax: +4 581 602 587 Email: sigmahra@sigmahra.cz 426
More informationDéfumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.
Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally
More informationContents. Spare parts list...16 Electrical wiring...17 Electrical components...18 Miscellaneous / Notes...19. Subject to change without notice DHA 250
3 Contents General safety information...4 Applications...5 Method of operation...5 Product description...6 Casing...6 Rotor...6 Filter...6 Fan for process- and reactivation air...6 Heater for reactivation
More informationCommercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
More informationSERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
More informationB.TECH. (AEROSPACE ENGINEERING) PROGRAMME (BTAE) Term-End Examination December, 2011 BAS-010 : MACHINE DESIGN
No. of Printed Pages : 7 BAS-01.0 B.TECH. (AEROSPACE ENGINEERING) PROGRAMME (BTAE) CV CA CV C:) O Term-End Examination December, 2011 BAS-010 : MACHINE DESIGN Time : 3 hours Maximum Marks : 70 Note : (1)
More informationZKL Bearings for Railway Rolling Stock
2 ZKL Bearings for Railway Rolling Stock ZKL Bearings for Railway Rolling Stock Railway industry is a very prospective sector worldwide and therefore ZKL pays particular attention to bearings for railway
More informationEC medium pressure axial fans. The effi cient system solution.
EC medium pressure axial fans. The effi cient system solution. GreenTech EC technology in a new dimension. Thanks to the new axial fans, our highly effi cient GreenTech EC technology is now available for
More informationFIRE DAMPER APPLICATION GUIDE
FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire
More informationAirline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
More informationKONRAD. Hybrid Fancoil Series
KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks
More informationCRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
More informationBSM MOTOR DRIVEN CENTRIFUGAL PUMPS
PRINCIPLE OF OPERATION A hydraulically and dynamically balanced impeller with raised vane sections discharges liquid as a result of the centrifugal force developed in rotation. The head developed is entirely
More informationFig 1 Power Transmission system of Tractor
POWER TRANSMISSION SYSTEM Transmission is a speed reducing mechanism, equipped with several gears (Fig. 1). It may be called a sequence of gears and shafts, through which the engine power is transmitted
More informationHorizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
More informationCerobear Spindle Bearings for Machine Tool Applications
Cerobear Spindle Bearings for Machine Tool Applications Cerobear Spindle Bearings About CEROBEAR Committed to the abbreviation CEramic in ROlling BEARings, CEROBEAR GmbH is the renowned world leader in
More informationsystemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair systemair Disclose the secret
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationApplication. Design. Structure. Acoustics
Application The SMART fans are designed for general ventilation of buildings. They are meant for forwarding dry air of maximum temperature + C, and dustiness not exceeding,3 g/m3, without viscous, aggressive
More informationSUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2
SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D600023 ISSUE DATE 08.06.1998 DAWN.
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationRFHD. ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d. According EU Regulation
RFHD ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d According EU Regulation free RFHD Centrifugal roof fans with horizontal outlet and ATEX Ex d certification Centrifugal roof fans with
More informationModel 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com
Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022
More informationCDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
More informationThe CLIPPER Solutions
The CLIPPER Solutions 111 112 C51 6,5 Hp Ø 350mm 76kg Compact, robust and highly manoeuvrable machines designed for both wet and dry cutting of concrete and asphalt. Machine delivered without diamond blade.
More informationTECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
More informationStainless Linear Motion Rolling Guide series
products are avaiable from: MARYLAND METRICS phones: (410)358-3130 (800)638-1830 faxes: (410)358-3142 (800)872-9329 P.O.Box 261 Owings Mills, MD 21117 USA URL: http://mdmetric.com E-mail: sales@mdmetric.com
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationHVAC air curtains. Type InduAir
Air Conditioning Cooling Heating Ventilation HVAC air curtains Type InduAir The Energy Saving air curtain for Industrial Applications InduAir The solid, self-supporting housing of the energy saving air
More informationHIGH SPEED SPINDLE MOTORS
DATA SHEET HM / HT and ES Ranges HIGH SPEED SPINDLE MOTORS Manual and Automatic Tool Change Compact, high speed, asynchronous motors with power ratings from 0.65 to 18 designed to provide long term reliability
More informationRotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
More informationNumber Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8)
1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 4 5 600130 Spring Washer (8mm) 4 6 600344 Roll Pin (M6x30) 4 7 600129 Socket Hd Cap Screw (M8x25) 4 8
More informationhore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
More informationTube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller
Tube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller Belt Drive Low and High Pressure October 009 Features Page Header Tube Axial Roof Upblast Fans Greenheck belt drive tube axial upblast
More informationLG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
More informationAir technology solutions for demanding applications. Product overview. www.elektror.com17
Air technology solutions for demanding applications Product overview www.elektror.com17 Set benchmarks now. Efficient and high-performance solutions from one source. For the past 9 years Elektror airsystems
More informationFan Selection Application
Fan Selection Application Instructions for Air Turbine Propeller s Axial Fan Selection website www.axialfanselection.com \ Air Turbine Propeller Company 22329 Perry Highway - Zelienople, PA 16037 (724)
More informationEnergy Saving ECM Motors and Fans. 2010 Ventilation Catalogue
Energy Saving ECM s and Fans 2010 Ventilation Catalogue CONTENTS For ellington, sustainability is about delivering products at competitive prices while preserving the environment for future generations.
More informationAn SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps
An SPX Process Equipment Operation Universal II Industrial Series Rotary Positive Displacement ECP Pumps New levels of performance. Reduced operational and maintenance costs. For more than half a century,
More informationRadial Insert Ball Bearings Housing Units. Our Expertise is Your Benefit. Schaeffler Group Industrial
Radial Insert Ball Bearings Housing Units Our Expertise is Your Benefit Schaeffler Group Industrial A p p l i c a t i o n s Quality for every eventuality: Radial insert ball bearings in industry Radial
More informationdp pumps the dynamics of water HVAC centrifugal (norm) pumps
dp pumps the dynamics of water HVAC centrifugal (norm) pumps 2 HVAC centrifugal (norm) pumps HVAC efficient solutions for comfortable living conditions To be comfortable in a building, both at home and
More informationMONDOATHENS BASKETBALL SET (Reference PK110)
MONDOATHENS BASKETBALL SET (Reference PK110) DESCRIPTION The MONDOATHENS backstop unit is mainly designed for multi-sports pavilions and installations where the highest-level basketball competitions are
More informationChilled Water Fan Coil Unit. Model:HFCA Size 03~14
Chilled Water Fan Coil Unit Model:HFCA Size 03~4 The Best Choice for Comfort =The Best Results Quiet Comfort Slope coil avoid air flow perpendicular impact Low noise permanent split capacitor motor Metal
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationVertical Pumps for the Oil & Gas Industry
Vertical Pumps for the Oil & Gas Industry ITT API Expert ITT Commitment ITT is committed to the Oil and Gas market, which is the largest segment of our business. We have been investing in technology to
More informationCENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc. 1 Centrifugal Pump- Definition Centrifugal Pump can be defined as a mechanical device used to transfer liquid of various types. As
More informationRadial piston pumps type R and RG
Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power
More informationPolishing and finishing barrels BTV
Polishing and finishing barrels BTV Polishing barrels for buttons, products in polyester, urea, galalith and related item. Strengthened model with rubber lining for finishing of metallic minuteness. Steel
More informationDiscPlus DX195 and DX225 Air Disc Brakes
Revised 11-04 Technical Bulletin Revised 1 Technical 11-04 Bulletin DiscPlus DX195 and DX225 Air Disc Brakes Inspection, Installation and Diagnostics Air Disc Brake Inspection Intervals and Procedures
More informationAC Electric Motors best practice
If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training
More informationRollers. from the UK s largest roller manufacturer. Quality Performance Reliability
Rollers from the UK s largest roller manufacturer Quality Performance Reliability 42 Index Gravity Rollers Light to Medium Duty 4 Heavy Duty 5 Plastic Rollers 6 Stainless Steel Rollers 7 Grooved Rollers
More information