1 Code Red - Fire Education Guide

2 TABLE OF CONTENTS Page # General Inquiries....1 Phone numbers by site for general inquiries 1.0 Fire Alarm First Stage 1.2 Second Stage 2.0 Evacuation Preparation for an evacuation 2.2 Progressive Stages of Evacuation 2.3 Evacuation by Compartments 2.4 Horizontal Evacuation 2.5 Vertical Evacuation 2.6 Total Building Evacuation 3.0 Responsibilities of Staff Area-specific Manager 3.2 Fire Safety Captain 3.3 General Staff 3.4 Area Staff 4.0 Fire Response REACT Smell of Smoke 4.2 Types of fires and extinguishers 4.3 Fire Hose 4.4 When to fight a fire 5.0 Fire Safety for Occupants Staff Responsibility 5.2 Occupant/Staff training 6.0 Fire Hazard Control Building decorations 6.2 General/Personal Housekeeping 6.3 Storage, Handling and Use of Flammable Liquids 6.4 Open Flame Hazards Control 6.5 Electrical equipment and Appliances 7.0 Prevention Tips Don t Give Fire a Place to Start

3 Code Red - Fire Education Guide FIRE EMERGENCY GENERAL INQUIRIES CHEDOKE CAMPUS GENERAL CAMPUS HENDERSON CAMPUS MUMC CAMPUS Emergency Fire Safety and Evacuation Information This Fire Instruction Guide has been compiled as a support document to the HHSC Code Red Procedures. This information is intended to provide advice on basic procedures and protocols to be followed in the event of a fire in the Hospital. Staff must be familiar with this content as well as the Corporate Code Red Procedure and their Area-Specific Code Red Procedure 1

4 1.0 Fire Alarm The Fire Alarm is a TWO stage alarm 1.1 First stage The first stage alarm within the 4 hospitals of Hamilton Health Sciences consists of slow sounding bells at 20 bells/minute. This is the Fire Emergency Alert. These bells ring throughout the entire facility. Along with the sounding bells, an overhead page is heard (where available) announcing CODE RED (Zone / Area / Dept. / Ward) - Code Red is the code for a fire emergency alert call. The slow sounding bells are meant to alert staff without alarming patients and visitors. The bells may automatically silence after approximately 3 minutes. This automatic reset or silencing of the bells does NOT signify an all clear. Once the fire area-specific is satisfied that the situation has been rectified, approval from the fire area-specific is given, and the all clear sounded. The all clear is announced by the fire bells with two bells (double ring) and/or an overhead page announcing: CODE RED - ALL CLEAR Zone / Area / Dept. / Ward. Note: Chedoke Campus - The Holbrook, Wilcox and the Continuing Care Centre - are on the two stage fire alarm system. ALL other buildings at Chedoke are on a single stage alarm, total and immediate building evacuation. 1.2 Second stage alarm Sounds at 120 bells / minute and if sounded if there is a need to evacuate the entire building. Once the second stage of the alarm is initiated your total building evacuation procedures come into effect. 2.0 Evacuation You must be prepared for evacuation. Know your exits, evacuation routes and procedures. After each drill review, maintain and update your area-specific Code Red Procedures. Areas of the Hospital are divided through compartmentation or special separations. These separations are found between sleeping rooms, treatment rooms, area-specifics and corridors (smoke barrier doors, every 75 feet along corridors). 2

5 2.0 Evacuation (continued) The fire separations confine the fire to a specific area (point of origin) and take approximately 1 hour to spread beyond an enclosed separation. Compartmentation is only effective if the doors and windows are kept closed thereby confining the fire and the smoke to the room of origin. Effective compartmentation allows time to stabilize and evacuate patients and staff from the immediate danger zone and for the fire team / fire dept. to initiate fire suppression procedures. 2.1 Preparing for Evacuation If time allows generate patient and staff evacuation lists. Under no circumstances are patients to be moved in their beds. This constricts hallways and corridors, endangering all of the area occupants. An exception is made for ICU, CRCU and some circumstances with PACU patients The placement of wet towels, blankets or sheets at the bottom of a closed door, assists with restricting a rapid transfer of smoke and generates extra time with which to complete area evacuation. Adjacent Wards and Area-specifics are advised to identify a buddy area which can provide mutual aid assistance in a Code Red. This Code Red mutual aid assistance program allows for the immediate addition of personnel from the adjacent areas to assist with the evacuation of an area that is in immediate danger. Your evacuation protocols should not assume that unlimited assistance is available from the Fire Department or other areas- exterior to your own. In most circumstances assistance is available; however, there may be situations where you are required to complete your evacuation protocols with the resources at hand. Ensure that you have ample space available in your evacuation staging areas to enable you to assemble your patients and resources. If time allows, prepare and gather priority medical resources (this includes blankets) that your area deems necessary to maintain a minimum level of care for your patient population if evacuation becomes necessary. Remember, once evacuation protocols have been initiated there are no guarantees that you are able to gain access to another inpatient care area. Your resource items must be essential items only and easily transportable (use a laundry bag). Have two horizontal evacuation routes, one primary route and one secondary route. These routes are always in the opposite direction of each other and in many cases, the secondary route entails traveling down the stairwell. 3

6 2.0 Evacuation (continued) 2.2 Progressive stages of evacuation Progressive stages of evacuation in the event of heavy smoke contamination or a fire within your area are: room of fire or smoke origin, then the adjoining rooms working out and away from the room of fire or smoke origin. Affix masking tape at eye level onto the center of the closed door of an evacuated room to indicate that the room has been checked and cleared. Rolls of 2 masking tape are contained within your emergency preparedness and emergency preparedness boxes. 2.3 Evacuation by Compartments Once in the corridor between a set of smoke barrier doors this is a compartment and it is designed as a point of refuge. By moving from compartment to compartment we can protect ourselves and patients without transporting or moving too far. This is referred to as horizontal evacuation. Intercompartmental movement is to be restricted to legitimate emergency and urgent tasks only. 2.4 Horizontal Evacuation (Primary Evacuation Route) To facilitate horizontal evacuation we need only move 3 or 4 compartments away from the danger zone. Inpatient wards are advised to move toward an adjacent inpatient care area. 2.5 Vertical Evacuation (Secondary Evacuation route) If you be faced with a vertical evacuation then movement is always down via the stairwell but never up or below grade or ground level. It may be necessary, in below grade or ground level situations, to initially evacuate to the exterior or outside of the building and then reenter via a main or side entrance. Once you have arrived within another area-you follow their area-specific Code Red evacuation routes and procedures. All Staff are reminded that in the event of any evacuation their assistance may be required to aid in the movement of patients. 2.6 Second Stage Total Building Evacuation During a second stage total building evacuation, staff are advised to refer to their area-specific Code Green Evacuation procedures. 4

7 2.0 Evacuation (continued) Total building evacuation entails exiting the building by the shortest route available. As with the horizontal evacuation, there are always two routes planned, one primary and one secondary, each in the opposite direction of the other. Staff must be prepared to apply maximum flexibility to their procedures. Evacuation routes may vary but your destination does not. Once a second stage evacuation is initiated all major resources, extra blankets, mattresses, medical supplies, portable oxygen etc. are acquired from ground level areas only. The size of the fire indicates the extent of the evacuation necessary. Horizontal evacuation can be self initiated if there is a clear and present danger. The decision for further evacuation is made in conjunction with the fire areaspecific who, upon their arrival assume command and control of the situation. 3.0 Responsibilities of Staff 3.1 Area Specific Manager An effective area-specific Fire Safety Plan depends upon the knowledge, experience and commitment of management personnel. Every supervisor must have a clearly defined role and the authority to respond appropriately. All new staff MUST receive training in the Fire Safety Plan before responsibilities can be delegated. Training for all staff members must be organized and be conducted at least annually. 3.2 Fire Safety Captain The area-specific Manager / Supervisor (or their delegate), is considered to be the Fire Safety Captain in their respective areas. The Fire Safety Captain (or delegate), is responsible for coordinating and assigning personnel to carry out instructions in each area during a Code Red condition. The Fire Safety Captain (or their delegate) must be easily and readily identifiable. The area-specific Fire Emergency Protocols are to be contained in the Areaspecific Emergency Procedures Manual and is to be maintained and kept available by the Fire Safety Captain in their respective areas. 5

8 3.0 Responsibilities of Staff (continued) It is also recommended that the area-specific Fire Emergency Protocols be broken down by protocol into an instant access card system. 3.3 Area Staff All staff return to the area-specific via the stairwells only. DO NOT USE ELEVATORS unless directed to do so by Fire Emergency personnel. Staff are to move quickly but cautiously. Approach stairwells and smoke barrier doors with due care and caution. Check to ensure that stairwells and beyond the smoke barrier doors are free and clear of fire and smoke conditions. Staff attending meetings at their home site immediately return to their respective area-specifics. Staff attending from other sites accompany home site Staff to their areas. Staff already in their work area at the time of the alarm are to 1. Sweep the work area and check: for fire conditions (smoke, heat, flame) that all doors and windows are closed that all exits have clear access that a portable fire extinguisher is available 2. Inform the Fire Safety Captain (or delegate), as to who is present in the work area. Generate Patient and Staff evacuation lists. Patients are evacuated in order of physical condition. A. Ambulatory - minimum number of staff required to lead group to safe area; B. Wheelchair patient (if wheelchairs are readily available); C. Critical patients ( those requiring the most resource to move ) as they need to be moved when the greatest amount of help is available; D. Those that resist. Under no circumstances are patients to be moved in their beds. This constricts hallways and corridors, endangering all of the area occupants. An exception is made for ICU, CRCU and in the PACU depending on the patient s circumstances. 3. Prepare important items for safe keeping or evacuation i.e. patient charts, priority medical resources, blankets. Items must not be cumbersome or constitute a hazard during an evacuation. Staff are to maintain a hands free condition in order to offer aid and assistance. 6

9 3.0 Responsibilities of Staff (continued) 4. Designate a person to stand by the telephone and ensure that telephone use is restricted to stat, emergency or urgent calls only. 5. Confine intercompartmental movement to a minimum. 6. Ensure visitor, patient and staff movement are controlled. 7. Once staff are safely within the area-specific they stay put unless there is a clear and present danger, then the area-specific Horizontal Evacuation Procedure is initiated. 8. Review Horizontal Intercompartmental and Total Building Evacuation Routes. In-Patient care areas - this review also includes Lifts and Carries. 9. STANDBY and await further instructions 10. REMAIN on emergency alert until the sounding of the all clear. 11. At the discretion of the manager or delegate staff may resume their duties within the confines of their area only. 4.0 Fire Response 4.1 REACT If a fire occurs, your immediate action - inaction can and does mean the difference between life and death. In Case of Fire: R - Remove all room occupants E - Ensure all doors/windows are closed A - Activate the Fire Alarm C - Call 5555 T - Try to extinguish the fire - if possible (ensure that Telecommunications understands clearly CODE RED and Location) 7

10 4.0 Fire Response (continued) Smell of Smoke 5555 is to be called for all and any untraceable burning smells 4.2 Types of Fires and Extinguishers TYPES OF FIRES CLASS A Wood, Paper, Textiles, People CLASS B Flammable Liquids FIRE EXTINGUISHERS PRESSURIZED WATER Stainless Steel Cylinder 2 ½ ft. high MULTIPURPOSE DRY CHEMICAL Coloured Cylinders MULTIPURPOSE DRY CHEMICAL Coloured Cylinders CLASS C Electrically energized fires DRY CHEMICAL Coloured Cylinders CO2 Red cylinder, black horn shaped nozzle TO OPERATE EXTINGUISHERS Remember the word P.A.S.S. Pull the pin - Twist pin to break the seal then remove Aim at the base of the flame - Aim Low Point the extinguisher nozzle or hose at base of the flame Squeeze the handles - Activating the extinguisher Sweep the fire - Sweep slowly - side to side, front to back, blanketing the fire with the extinguishing agent Blankets These are extremely valuable for use as an improvised fire extinguisher to smother a fire or wrap around a person whose clothing has ignited. 4.3 Fire hose Fire Hoses are restricted to Fire Team / Fire Area-specific Use Only and must not be removed from the rack or cabinet. 4.4 When to Fight a Fire Fight the fire only if all of the following are true: the fire is small and confined to the immediate area where it started (e.g. wastebasket, electrical appliance, couch cushion etc.) you can fight the fire with your back to the door at all times your fire extinguisher is rated for the type of fire you are fighting and it is in good operational condition. 8

11 you have had the required training in the use of fire extinguishers and are confident that you can operate it effectively. If you have the slightest doubt about whether or not to fight a fire, get out and stay out, closing the door behind you. 5.0 Fire Safety for Occupants 5.1 Staff Responsibility It is the responsibility of all personnel to read and be familiar with the procedures and protocols to be followed in the event of fire or other emergencies. All personnel are to follow the instructions of, and cooperate with the requirements of the Ontario Fire Code, Ontario Building Code, Corporate and area-specific Code Red Protocols and Procedures. All personnel are responsible to ensure that they know the following: the location of fire extinguishers; the class / type of fire each extinguisher is designed to extinguish; how to operate the fire extinguishers; the location of the fire alarm pull stations and how to operate them; the location of exits; that all staff participate in code red drills and reviews; the procedures to follow in the event of a fire as directed in the Corporate and Area-specific Code Red Orders; the location of designated area-specific assembly areas to report to when evacuating the building; that all fires are reported regardless of size of fire or whether or not it has been extinguished; that it is a serious offence to tamper in any way with fire and life safety equipment, including smoke detecting devices and fire extinguishers; when fire and/or life safety hazards are observed they are reported immediately to your supervisor; fire prevention measures appropriate to your work environment; and inform your supervisor if you require special assistance to evacuate the building. 5.2 Occupant / Staff Training All personnel working within buildings of Hamilton Health Sciences are instructed by their supervisors as to their individual responsibilities for general fire safety of the building and its occupants as follows: All new employees attend a Corporate Fire Safety Orientation session at New Employee Orientation, are provided with a copy of Corporate and area-specific Code Red procedure to read and they are also briefed by their supervisor as to: the location of fire alarm pull stations, fire exits and fire extinguishers within and adjacent to their place of work; fire prevention measures appropriate to their work environment. Every staff/affiliate member of HHS buildings is responsible to review monthly: 9

12 6.0 Fire Hazard Control the location and contents of the Corporate and Area-specific Code Red protocols and procedures; the location of fire alarm pull stations, fire exits and fire extinguishers within and adjacent to the place of work; fire prevention measures appropriate to their work environment and; attend a Corporate Fire Safety session (annual) 6.1 Building Decorations Decorations only fire retardant/flame resistant decorations and decorating materials can be used in HHSC buildings. open flame decorations, such as candles are not permitted. exits must be maintained free of obstructions and are used for no purpose other than exiting. fire retardant chemicals must not be used on decorative materials (Because it is virtually impossible to attain an acceptable degree of fire retardant using fire retardant chemicals on paper and most other materials) fire retardant chemicals applied at point of manufacture only are acceptable. natural Christmas trees and tree boughs are not permitted in HHS buildings. decorations must not be placed on or within one meter (3 ft) of electrical lamps, heating appliances, heating piping, etc. decorations can not be hung on doors or door casings decorations must be hung up out of the reach of personnel. fire hazards such as straw and/or hay are not permitted inside HHSC buildings. electrical Lights - used for decoration must be of an approved type and must pass inspection by HHSC electricians. Decorating for Social Events at HHS the prior approval of HHS Fire Prevention Area-specific is obtained relative to the fire retardant quality of the decorative material and the decoration plan in general when buildings or rooms are to be decorated for specific social functions and seasons such as Christmas and New Years, Halloween, Easter, etc. a fire inspection may be carried out by the HHS Fire Prevention Area-specific prior to and after the function. 10

13 6.0 Fire Hazard Control (continued) 6.2 General / Personal Housekeeping Rubbish and waste material Contribute to many fires and are frequently classed as fire hazards. Except in cases of spontaneous ignition, they do not actually cause the fire but they can furnish the fuel that is easily ignited by small sources of heat and allow the fire to spread quickly. Maintenance of a high standard of housekeeping is essential in the prevention of fire. Indoors Proper and regular disposal of waste paper and other combustible material is important. At the end of each work day, waste material is removed from the building and deposited in the bulk containers provided. Outdoors Cleanliness and good housekeeping are just as essential outdoors, therefore, rubbish and waste materials is not allowed to accumulate. Oily Waste Oily waste, oily clothing, wiping rags, and other materials that are contaminated with flammable or combustible liquids are subject to spontaneous ignition, and are required to be stored in an oily waste can bearing the label of the Factory Mutual Laboratories. The oily waste cans are to be emptied at the end of each working day and the oily waste removed from the building and stored in metal containers. 6.2 Storage, Handling And Use Of Flammable Liquids This section applies to the storage, handling and use of flammable liquids in portable containers inside buildings. Flammable liquids are those having a flash point below 100 deg. F, such as gasoline, alcohol and acetone. Storage Precautions for Flammable Liquids Additional requirements are necessary for the safe storage and use of liquids that have one or more of the following properties: unusual burning characteristics; subject to self-ignition when exposed to air; 11

14 6.0 Fire Hazard Control (continued) highly reactive with other substances; subject to explosive decomposition; and other special properties that indicate a need for special safeguards. Under Section (1) of the Ontario Fire Code all Recirculating Ventilation Systems (Fume hoods), require that a fail-safe vapour detection and alarm system be installed to continuously monitor the flammable vapour concentration in the exhaust air. The Faculty of Health Sciences has installed Ventalert systems in the University laboratory s in compliance with the Code. Information on this system is available from MUMC Engineering Services. flammable liquid containers and storage cabinets are not stored near exits, stairways or other areas normally used by and for the safety of personnel. storage facilities are approved by the HHS Fire Prevention Area-specific and/or, if required, the Fire Prevention Area-specific of the Hamilton Fire Areaspecific; where required for ready use, quantities of flammable liquids not exceeding the quantities allowed by Section 4 of the Ontario Fire Code, may be stored in buildings. storage is in approved containers and placed in labeled metal flammable liquids storage cabinets indicating that no smoking or open flames are permitted in the area. flammable liquids in quantities exceeding the quantity allowed for ready use by Section 4 of the Ontario Fire Code, are to be stored only in approved compounds or specially designed rooms or buildings. Handling of Flammable Liquids the dangers associated with dispensing and handling of a low flash point liquid are brought to the attention of all concerned by the area supervisor. flammable liquids are not handled, drawn or dispensed where flammable vapours may reach a source of ignition; due to the volatility of low flash point flammable liquids, extreme caution must be undertaken when dispensing liquids from one container to another e.g. refueling lawnmowers, hedge trimmers, etc. refueling is not done inside the buildings flammable liquids having flash points below 100 deg. F are not used as a cleaning solvent. 6.4 Open Flame Hazards Control A WELDING / HOT WORK permit is required for all cutting and welding and/or use of open flame. 12

15 6.0 Fire Hazard Control (continued) Staff engaged in HOT WORK ensure that a fire extinguisher is available and instantly accessible at all times. 6.5 Electrical Equipment And Appliances Electrical Equipment is installed and maintained in accordance with requirements and standards of the Electrical Code and applicable construction engineering technical orders. electrical equipment and appliances are of a type approved by the Canadian Standards Association (CSA), Underwriters Laboratories of Canada (ULC), Factory Mutual (FM), Underwriters Laboratories Inc. (ULI). installation and maintenance of electrical wiring, equipment and appliances is not carried out by personnel other than authorized HHSC electricians and technicians or competent electrical contractors approved by HHSC. Appliances privately owned electrical appliances are of an approved type (see: electrical equipment and appliances section above). it is the owner s responsibility to ensure that all appliances are operated safely and maintained in good electrical and mechanical condition. electrical kettles are equipped with an automatic shut off feature. Extension Cords only approved flexible extension cord sets are used the cord is not permitted to carry more than its rated current carrying capacity. extension cords are not to be supported by staples nor looped or tied around metallic objects such as nails, metal pipes, etc. extension cords are maintained in good condition without cuts, frays or kinks and are maintained as manufactured without alteration of any kind. Hazardous Locations Only wiring, equipment and appliances approved for use in a hazardous locations are used for that purpose. Portable electrical Heaters Only approved type (Electrical), heaters are used. When authorized for use, heaters are not placed under furnishings or in a location where clothing, paper or other combustible material may come into contact with them or be ignited by radiant heat. 13

16 7.0 Prevention Tips Don t give Fire a place to start THINK FIRE PREVENTION Report fire hazards Know your area s fire procedures Attend the fire classes Know your fire exits and where they KNOW Keep exits and corridors clear of obstructions Your area s fire alarm pull station location Observe the No Smoking Regulations Your area s fire protection equipment lead to Practice good housekeeping Know your Horizontal / Total Building Participate in all fire drills, routes and procedures evacuation 14

Fire & Safety. Fire Safety Training For FHSc Staff and Students in Health Care Facilities

Fire & Safety. Fire Safety Training For FHSc Staff and Students in Health Care Facilities Fire Safety Training For FHSc Staff and Students in Health Care Facilities Staff must know how to respond to a Fire Emergency Actions to take upon discovering a fire Actions to take upon hearing the fire

More information

Fire Safety PROCEDURES January 2011

Fire Safety PROCEDURES January 2011 Fire Safety PROCEDURES January 2011 firesafety@uwo.ca Campus Phones EMERGENCY Dial 911 Fire Safety Service is the focal point for the coordinated administration of the University Fire Safety program and

More information

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No General Inspection FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS 1. All Floors (inspect from top floor to basement): Yes are fire exits and directional signs properly illuminated? is the emergency

More information

Fire Response Plan - Code Red

Fire Response Plan - Code Red Fire Response Plan - Code Red SUMMARY & PURPOSE The purpose of the Fire Response Plan Code Red is to provide guidelines for hospital personnel to follow during a Code Red. As more fully described below,

More information

FIRE SAFETY ONLINE TRAINING

FIRE SAFETY ONLINE TRAINING INTRODUCTION This Fire Safety Training module is designed to teach you preventive measures that will eliminate or minimize causes of fire or fire hazards in the workplace, and to teach you proper emergency

More information

St. John s University Fire Safety Plan

St. John s University Fire Safety Plan St. John s University Fire Safety Plan Flynn Hall St. John s University Fire Safety Plan Part 1-Building Information Section Flynn Hall 300 Howard Ave. Staten Island, N.Y. 10301 Fire Safety Director: Address:

More information

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result

More information

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS The attached self-inspection form is intended for staff use at regular, frequent intervals. It should not take the place of two other vital measures

More information

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS 1.0 PURPOSE 1.1 To provide an overview of fire extinguisher use

More information

St. John s University

St. John s University St. John s University Fire Safety Plan Founder s Village Townhouses Page 1 St. John s University Fire Safety Plan Part 1-Building Information Section Founder s Village Townhouses 8000 Utopia Parkway Jamaica

More information

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to

More information

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario Fire Code, Part 4, and of the Regulations for

More information

FIRE RISK ASSESSMENT

FIRE RISK ASSESSMENT REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT This template has been provided to assist the Responsible Person with the preparation of a Fire Risk Assessment and is not intended for commercial

More information

FIRE SAFETY FOR OFFICE WORKERS

FIRE SAFETY FOR OFFICE WORKERS FIRE SAFETY FOR OFFICE WORKERS This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of the program and the subject

More information

Fire Safety. Workbook Second Edition, 2004

Fire Safety. Workbook Second Edition, 2004 24-Hour Residential Services Fire Safety Workbook Second Edition, 2004 Based on previous contributions of: No part of this publication may be produced, stored in a retrieval system or transmitted in any

More information

Workplace Fire Safety

Workplace Fire Safety Teaching Guide Workplace Fire Safety for staff Seattle Fire Department Fire Prevention Division Workplace Fire Safety Instructor Outline Introduction Goals: To ensure that employees are knowledgeable in

More information

FIRE AND LIFE SAFETY TRAINING

FIRE AND LIFE SAFETY TRAINING FIRE AND LIFE SAFETY TRAINING 1 Objectives General Information Emergency Evacuation Plans / Regulatory Requirements Notification Systems Emergency Exits and Fire Doors Electrical Safety Fire Prevention

More information

The Johns Hopkins Hospital and The Johns Hopkins University Health, Safety and Environment Manual Fire Safety:

The Johns Hopkins Hospital and The Johns Hopkins University Health, Safety and Environment Manual Fire Safety: Page 1 of 10 Keywords: Emergency Room, Evacuation, Evacuation Plans, Fire, Fire Incident Responsibilities, Fire Safety, Gas Shutoff, Inpatient Area, Intensive Care, JHH Fire Incident Responsibilities,

More information

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS Fire Safety Technical Guide UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS 1.0. BACKGROUND 1.1. The Regulatory Reform (Fire Safety) Order (known Fire Safety Order) applies to England and Wales (Northern

More information

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29CFR1910.36-29CFR1910.38-29CFR1910.157-29CFR1910.165 NFPA-10 BASIS: The OSHA Emergency Action Planning and the

More information

FIRE EXTINGUISHER TRAINING

FIRE EXTINGUISHER TRAINING FIRE EXTINGUISHER TRAINING Fire safety, at its most basic, is based upon the principle of keeping fuel sources and ignition sources separate. Three things must be present at the same time to produce fire:

More information

Residential Fire Safety Policies

Residential Fire Safety Policies Residential Fire Safety Policies Introduction University Housing and Campus Code Compliance and Fire Safety at the City University of New York at Queens College in compliance with the Higher Education

More information

FIRE PREVENTION & INVESTIGATION DIVISION 125 Idylwyld Drive South Saskatoon, SK S7M 1L4 Phone: (306) 975-2578 Fax: (306) 975-2589.

FIRE PREVENTION & INVESTIGATION DIVISION 125 Idylwyld Drive South Saskatoon, SK S7M 1L4 Phone: (306) 975-2578 Fax: (306) 975-2589. FIRE PREVENTION & INVESTIGATION DIVISION 125 Idylwyld Drive South Saskatoon, SK S7M 1L4 Phone: (306) 975-2578 Fax: (306) 975-2589 Bulletin 16-12 Fire Drills This guideline was developed to assist persons

More information

Portable Fire Extinguisher Presentation

Portable Fire Extinguisher Presentation Slide 1 Fire Extinguisher Training A requirement of all Clemson University Employees as mandated by OSHA: Portable fire extinguishers. - 1910.157 Welcome to the Clemson University Online Fire Extinguisher

More information

and Extinguisher Training

and Extinguisher Training RACES Field Operations Course -Unit 10 Fire Safety Awareness and Extinguisher Training Developed in cooperation with the National Fire Protection Association and the Public Information and Life Safety

More information

Notes. Material 1. Appropriate Flammable Liquids

Notes. Material 1. Appropriate Flammable Liquids 29 CFR 1910.106 Flammable Materials Flammable Liquids Preparation 1. Read Applicable Background information and related Company Policy Chapter. 2. Make Copies of this Lesson Plan for Personnel 3. Make

More information

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600 OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done

More information

FIRE PREVENTION PLAN

FIRE PREVENTION PLAN FIRE PREVENTION PLAN 1 FIRE PREVENTION PLAN OSHA s Fire Prevention Plan regulation, found at 29 CFR 1910.38(b) and 29 CFR 1926.24, requires Northern Clearing, Inc. to have a written fire prevention plan

More information

1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency;

1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency; Fire Action Plan FIRE ACTION PLAN SEStran aims to provide and maintain safe & healthy working conditions, equipment and systems of work for all our employees, and to provide such information, training

More information

OSHA Office of Training and Education 1

OSHA Office of Training and Education 1 Flammable and Combustible Liquids OSHA Office of Training and Education 1 Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and

More information

TCC Fire Regulations Exhibits & Displays in Public Buildings

TCC Fire Regulations Exhibits & Displays in Public Buildings TCC Fire Regulations Exhibits & Displays in Public Buildings TCC Fire Regulations The purpose of these requirements is to maintain an acceptable level of fire safety within The Toronto Congress Centre

More information

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable

More information

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT INTRODUCTION No matter how reliable fire protection equipment may seem, periodic maintenance is needed to ensure proper operation. Fire protection

More information

Fire Safety Log Book

Fire Safety Log Book Fire Safety Log Book Company... Address........ Responsible Person. Competent Person. Date Started For Additional Information: Safety Management (UK) Ltd Holme Suite, Clawthorpe Hall Business Centre, Burton

More information

1.0 Purpose... 4. 2.0 Definitions...4. 3.0 Hot Work Operations. 5

1.0 Purpose... 4. 2.0 Definitions...4. 3.0 Hot Work Operations. 5 HOT WORK PROGRAM Introduction The University of Kentucky recognizes a potential for fire from hot work operations. For that reason this program should be implemented in all departments at the University

More information

Fire Extinguishers. A Health and Safety Guideline for Your Workplace. Fire Extinguishing Methods. Introduction. Types of Extinguishers

Fire Extinguishers. A Health and Safety Guideline for Your Workplace. Fire Extinguishing Methods. Introduction. Types of Extinguishers A Health and Safety Guideline for Your Workplace Introduction Fire extinguishers are designed to put out or control small fires. A small fire, if not checked immediately, will soon spread out of control.

More information

exit routes and fire protection

exit routes and fire protection exit routes and fire protection OSHA 11 Exit Routes and Fire Protection Osha 11 Exit Routes and Fire Protection Exit routes and fire protection Learning Objectives By the end of this lesson, students will

More information

Fire Safety Risk Assessment Checklist for Residential Care Premises

Fire Safety Risk Assessment Checklist for Residential Care Premises Checklist for Residential Care Premises Name of Premises: Address of Premises: Name of Responsible Person: What area / location does the assessment cover? Does the assessment cover the whole site YES or

More information

Name Of Occupancy Date. Yes No Describe

Name Of Occupancy Date. Yes No Describe FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address

More information

North York General Hospital Policy Manual

North York General Hospital Policy Manual Page 1 of 6 POLICY STATEMENT North York General Hospital staff is responsible to follow the guidelines outlined in this document in the event of a fire to minimize injury and/or damage. DEFINITIONS Code

More information

Healthcare Help Supporting Health Providers. Module 2 Resources for Fire Warden Refresher Training HH.NET LTD

Healthcare Help Supporting Health Providers. Module 2 Resources for Fire Warden Refresher Training HH.NET LTD Healthcare Help Supporting Health Providers Module 2 Resources for Fire Warden Refresher Training HH.NET LTD Introduction This training shows what to do if you find fire. People might panic.... People

More information

Emergency Evacuation Plan: 232 King St.

Emergency Evacuation Plan: 232 King St. Emergency Evacuation Plan: 232 King St. Effective Date: July 2003 Revisions: 0 Approved on: April 20, 2004 Table of Contents 1.0 Building Resources... 1 2.0 Human Resources... 2 3.0 Definitions... 3 4.0

More information

Queen's University Environmental Health and Safety

Queen's University Environmental Health and Safety April, 2009 1 SOP-Chem-08 1.0 Introduction This document is intended as a guide to the Queen s University requirements for handling and storing flammable and combustible material in non-laboratories areas.

More information

FLA S FIRE SAFETY INITIATIVE

FLA S FIRE SAFETY INITIATIVE Improving Workers Lives Worldwide FLA S FIRE SAFETY INITIATIVE Preventing fires and saving lives by empowering workers and factory managers SCENARIO 1 OCCURS AT FACTORY ABC, WHICH HAS NOT IMPLEMENTED NECESSARY

More information

FIRE RISK ASSESSMENT

FIRE RISK ASSESSMENT The Regulatory Reform (Fire Safety) Order 2005 FIRE RISK ASSESSMENT Employer or other responsible person Name of Premises Address Post Code Telephone N o Name of Assessor(s) Date of Assessment Date of

More information

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.

More information

Fire Risk Assessment For Simple Premises

Fire Risk Assessment For Simple Premises Fire Risk Assessment For Simple Premises Responsible Person (Employer or other person having control of the relevant premises) Company / Premises Name Address of Premises Postcode Primary Use of Premises

More information

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or

More information

RESIDENTS FIRE SAFETY INFORMATION PACK

RESIDENTS FIRE SAFETY INFORMATION PACK RESIDENTS FIRE SAFETY INFORMATION PACK MARIE CURIE SCEAUX GARDENS ESTATE LONDON SE5 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information

More information

RESIDENTS FIRE SAFETY INFORMATION PACK

RESIDENTS FIRE SAFETY INFORMATION PACK RESIDENTS FIRE SAFETY INFORMATION PACK CASTLEMEAD CAMBERWELL ROAD LONDON SE5 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information

More information

Action required (Please tick) If you answered YES, record Action Points at STEP 4

Action required (Please tick) If you answered YES, record Action Points at STEP 4 RECORD OF FIRE SAFETY RISK ASSESSMENT Building Name & Use: Address: Postcode: Name of person(s) with fire safety duties: Name and contact details of assessor: Date of Assessment: 6 th February 2011 Laurel

More information

Flammable Liquids Storage

Flammable Liquids Storage A Health and Safety Guideline for Your Workplace Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario

More information

HOT WORK PERMIT PROGRAM TRAINING. John Braun

HOT WORK PERMIT PROGRAM TRAINING. John Braun HOT WORK PERMIT PROGRAM TRAINING John Braun 1.0 INTRODUCTION 1.2 Purpose The Hot Work Permit Program has been developed for University employees that work on or around hot work activities. This program

More information

HOT WORK PERMIT PROCEDURES

HOT WORK PERMIT PROCEDURES COLUMBIA UNIVERSITY ENVIRONMENTAL HEALTH & SAFETY HOT WORK PERMIT PROCEDURES COLUMBIA UNIVERSITY MEDICAL CENTER February 2010 1 TABLE OF CONTENTS A. PURPOSE 3 B. SCOPE 3 C. POLICIES AND PROCEDURES 3-4

More information

Flammable and Combustible Liquids. Slide 1 (of 23)

Flammable and Combustible Liquids. Slide 1 (of 23) Flammable and Combustible Liquids Slide 1 (of 23) Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and storage of flammable liquids

More information

An inventory of hazardous materials used in your workplace will prove useful.

An inventory of hazardous materials used in your workplace will prove useful. Introduction Fire Protection is an organized approach designed to prevent fires. In the event of a fire, a fire protection program will help prevent or minimize personal injuries, losses, and harm to the

More information

HISTOLOGY LABORATORY EMERGENCY PROCEDURES

HISTOLOGY LABORATORY EMERGENCY PROCEDURES HISTOLOGY LABORATORY EMERGENCY PROCEDURES CONTENTS 1 Chain of command...3 2 Disaster plan...3 2.1 Announcement 2.2 Pathology departmental duties 2.3 Reference 3 Evacuation...4 3.1 Meeting place 3.2 Evacuation

More information

NORTH BIRMINGHAM ACADEMY

NORTH BIRMINGHAM ACADEMY NORTH BIRMINGHAM ACADEMY FIRE AND EVACUATION PROCEDURES FIRE DRILLS: These are carried out once a term. Observations and details of each drill are recorded in the logbook, which is kept by the Assistant

More information

Course of Construction Questionnaire

Course of Construction Questionnaire Course of Construction Questionnaire CLIENT DETAILS Broker: Contact: Insured s name: Policy number: Address undergoing works: Insured s contact phone number: 1) Name and address of Contractor: 2) Contractor

More information

Company Name Chemical Spill Prevention & Clean-up Procedures Program. Last Revised On 00/00/0000

Company Name Chemical Spill Prevention & Clean-up Procedures Program. Last Revised On 00/00/0000 Company Name Chemical Spill Prevention & Clean-up Procedures Program Last Revised On 00/00/0000 PURPOSE The following program will discuss how prevent chemical spills from occurring and setting forth procedures

More information

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use. Walmart Standards for Suppliers Section 7. Health and Safety 7. Health and Safety Suppliers must provide workers with a safe and healthy work environment. Suppliers must take proactive measures to prevent

More information

Flammable Liquids Storage

Flammable Liquids Storage A Health and Safety Guideline for Your Workplace Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario

More information

NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION

NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION Fire and Life-Safety Group (FLS) I. EMERGENCY PROCEDURES The emergency procedures for natural gas emergencies are similar to that for fire emergencies.

More information

RESIDENTS FIRE SAFETY INFORMATION PACK

RESIDENTS FIRE SAFETY INFORMATION PACK RESIDENTS FIRE SAFETY INFORMATION PACK PERRONET HOUSE PRINCESS STREET LONDON SE1 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information

More information

ADMINISTRATIVE SERVICES MANUAL

ADMINISTRATIVE SERVICES MANUAL Purpose Responsibilities Proper Storage and use of flammable liquids can significantly reduce the possibility of accidental fires and injuries. To minimize risk to life and properly, the requirements of

More information

CBD-233. Fire Alarm and Detection Systems

CBD-233. Fire Alarm and Detection Systems Page 1 of 5 CBD-233. Fire Alarm and Detection Systems Originally published August 1984. R.H.L. McEwen Fire alarm systems are normally required by building codes. In the case of new buildings, this is usually

More information

Housekeeping and Material Storage

Housekeeping and Material Storage 29CFR 1926.20(b)-Accident Reduction, 29CFR 1926.21- Safety Training & Education 29CFR 1926.20(a)-Unsafe Working Conditions Housekeeping and Material Storage Preparation 1. Read Applicable Background information

More information

Spray Booth Guideline

Spray Booth Guideline Department of Development Service 135 North D Street, Perris CA. 92570 Phone: (951) 443-1029 Fax: (951) 943-3293 PURPOSE The intent of this guideline is to provide the information necessary to ensure that

More information

Hotel Fire Safety for staff

Hotel Fire Safety for staff Teaching Guide Hotel Fire Safety for staff Seattle Fire Department Fire Prevention Division Hotel Fire Safety Instructor Outline Introduction Goals: To ensure that hotel employees are knowledgeable in

More information

FIRE SAFETY HANDBOOK

FIRE SAFETY HANDBOOK 29 CFR 1960.20, Alternate Standard For Fire Safety In Airport Traffic Control Towers (ATCTs) Fire Prevention Plan (FPP) Emergency Action Plan (EAP) FIRE SAFETY HANDBOOK DEPARTMENT OF TRANSPORTATION FEDERAL

More information

LANCASTER UNIVERSITY. MANUAL OF SAFETY Section 29 POLICY ON FIRE RISK ASSESSMENTS

LANCASTER UNIVERSITY. MANUAL OF SAFETY Section 29 POLICY ON FIRE RISK ASSESSMENTS LANCASTER UNIVERSITY MANUAL OF SAFETY Section 29 POLICY ON FIRE RISK ASSESSMENTS 1 Introduction 1.1 The Fire Precautions (Workplace) Regulations, require the University to carry out fire risk assessments

More information

(Sample) Building Emergency Plan

(Sample) Building Emergency Plan (Sample) Building Emergency Plan for XXXXXX 2815 Commons Way Cincinnati, OH 45221 August 2016 University of Cincinnati Department of Public Safety Department a 2 Table of Contents A. Introduction B. Components

More information

Fire Damage. To Help Prevent. a Guide

Fire Damage. To Help Prevent. a Guide a Guide To Help Prevent Fire Damage Fire damage in your home can be costly and emotionally devastating. The damage caused by the flames and smoke can destroy a lifetime of memories in a matter of minutes.

More information

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION Page No: 1 of 7 6.0 PURPOSE (192.751) All possible precautions shall be exercised to prevent the accidental escape and ignition of gas. Whenever possible, potential sources of ignition should be eliminated

More information

THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514)

THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514) THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514) I EXERCISE of the powers conferred by section 41 2(k) of the Factories and other places of Work Act, the Minister for Labour and Human Resource Development

More information

Reviewed: Revised: 12/09. Page: 1 of 9

Reviewed: Revised: 12/09. Page: 1 of 9 Section: Emergency / Disaster Plan II Title/Subject: Clinic Evacuation Policy Number: Reviewed: Revised: 12/09 Page: 1 of 9 Purpose: The purpose of this Emergency Evacuation Plan is to ensure that the

More information

Safe Operating Procedure

Safe Operating Procedure Safe Operating Procedure (Revised 07/09) HOT WORK PERMIT OPERATIONS (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Authority In recognition of the

More information

Fire Safety Requirements for Child Care Centre

Fire Safety Requirements for Child Care Centre Fire Safety Requirements for Child Care Centre A. Restrictions on Location Child care centre shall not be located : - (a) (b) in any premises designed for residential use; in any industrial building, warehouses,

More information

Fire Safety in Laboratories. University of Tennessee Environmental Health and Safety

Fire Safety in Laboratories. University of Tennessee Environmental Health and Safety Fire Safety in Laboratories University of Tennessee Environmental Health and Safety Fire Safety in Laboratories Fire Prevention is a vital aspect of laboratory safety. Requires knowledge and constant vigilance

More information

Fire Risk Assessment Safety Checklist

Fire Risk Assessment Safety Checklist Fire Risk Assessment Safety Checklist This checklist has been prepared to help you comply with The Regulatory Reform Fire Safety Order 2005 What is the Regulatory Reform (Fire Safety) Order 2005? The Regulatory

More information

On-Line Fire Extinguisher Training

On-Line Fire Extinguisher Training On-Line Fire Extinguisher Training The USC Fire Safety Office is delighted you have chosen to take the on-line version of our fire extinguisher training. This power-point presentation will give you some

More information

How To Evacuate The University Of California Building

How To Evacuate The University Of California Building University of California Washington Center Emergency Evacuation Plan UC Washington Center 1608 Rhode Island Ave., NW Washington, DC 20036 Revised February 16, 2012 I. Purpose of the Plan II. Building Description

More information

General Fire Code Requirements Within Commercial Tenant Spaces

General Fire Code Requirements Within Commercial Tenant Spaces FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding

More information

Compressed Gas Cylinder Program

Compressed Gas Cylinder Program Department of Environmental Health & Safety Procedures Compressed Gas Cylinder Program March 2010 Compressed Gas Cylinder Program Page 1 of 8 Table of Contents I. Introduction II. III. IV. Policy Scope

More information

Texas Department of Insurance. Fire Safety. Provided by. Workers Health & Safety. Pub. No. HS01-028D (7-08)

Texas Department of Insurance. Fire Safety. Provided by. Workers Health & Safety. Pub. No. HS01-028D (7-08) Texas Department of Insurance Provided by Workers Health & Safety Pub. No. HS01-028D (7-08) A fire safety plan is an essential part of any workplace safety program. In fact, the Occupational Safety and

More information

Presented by: Rich Perry Marsh Risk Consulting

Presented by: Rich Perry Marsh Risk Consulting Flammable and Combustible Liquids Presented by: Rich Perry Marsh Risk Consulting What s the Big Deal? Flammable and combustible liquids are easily ignited Ignite with explosive force Burn readily and give

More information

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or comments regarding the

More information

Fire Prevention Plan for Commons 1655 Musketeer Drive

Fire Prevention Plan for Commons 1655 Musketeer Drive Commons for Commons 1655 Musketeer Drive Xavier University November 7, 2006 Ken Grossman Page 1 10/29/2013 Table of Contents Introduction... 3 Responsibilities... 3 Major Workplace Fire Hazards... 3 Methods

More information

VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO USE

VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO USE Nuclear Safe Work Practice 6.7 Safety Signs/Tapes/Ropes/Chains and Tags 1.0 PURPOSE/SCOPE To provide consistent standards for using safety signs, tapes, ropes and chains (barriers) to communicate existing

More information

Safety Inspection Checklist

Safety Inspection Checklist Inspector(s): Building: Room Number (s): Department/Unit: Date Inspected: Supervisor: To customize your local inspection checklist, delete or add as required. Inspection Headings: 1. Administrative 8.

More information

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012 Medicine Hat Fire Department Special Event Requirements August 202 medicinehat.ca/fire The following is a standard guide for event organizers to ensure occupant safety and compliance with the Alberta Fire

More information

15GAL STEEL OIL DRAIN WITH 110V PUMP

15GAL STEEL OIL DRAIN WITH 110V PUMP 15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

Manor/Nursing Home Emergency Plan (Guide)

Manor/Nursing Home Emergency Plan (Guide) Manor/Nursing Home Emergency Plan (Guide) Version 2010 1 AUTHORITY All disaster planning in the comes directly under the Administrator. Authority is delegated by the Administrator to the various members

More information

FLAMMABLE LIQUIDS COMPLIANCE NOTE

FLAMMABLE LIQUIDS COMPLIANCE NOTE Issued by: Heather Rice Page: 1 of 7 COMPLIANCE NOTE INTRODUCTION This document provides additional guidance to support the Arrangement on Flammable Liquids (Ref No. CYC/HS/A27) CONTENTS Section Topic

More information

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors. September 14, 2012 Dear AMM Member: Please see the attached Fire Code Frequently Asked Questions. This document was compiled by the Office of the Fire Commissioner at the AMM s request to help clarify

More information

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use. Large Facility Fire Safety Checklists and Logs This package contains checklists to ensure that all fire and life safety equipment are properly inspected. There are also logs on which to record the inspections

More information

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY Page 1 of 7 ISSUED: 5/00 REVISED: 08/06 1. Potential Releases of Radioactive Materials to Unrestricted Areas The Environmental Health and Safety Department (EHRS) must be notified immediately if an emergency

More information

Fire Protection Plan

Fire Protection Plan Fort Knox Installation Safety Office Fire Protection Plan Fire Protection Plan A fire prevention measure must be developed for all fire hazards found. Once employees are made aware of the fire hazards

More information

Fire Safety Plan University Stadium

Fire Safety Plan University Stadium Fire Safety Plan University Stadium Building # 53 Safety, Health, Environment Effective: March 14, 2018 Revised: December 2014 Revision: 1 Approved on: Pending Approval WILFRID LAURIER UNIVERSITY Contact:

More information