50/84 Place Fusion Furnace

Size: px
Start display at page:

Download "50/84 Place Fusion Furnace"

Transcription

1 Suitable for: Large labs Samples per day including standards Available in Natural Gas Liquefied Petroleum Gas OIL (diesel) FURNACE & ASSAY S U P P L I E S 50/84 Place Fusion Furnace Crucibles: 50 x 50gram 50 x 65gram 84 x 30gram 84 x 40gram 84x 55 gram Working Area 650mm Deep 220mm Wide 350mm High Pair With 00 or 68 Place Cupellation Furnace Electric 00 Place Cupellation Furnace Tel: info@fandasupplies.com Website: fandasupplies.com/

2 200 mm 985 mm Construction Base construction uses high-quality 00x 00 RHS. 980 mm Furnace body construction is durable 5mm laser-cut plate High quality refractory brick and insulation Bolt holes in base plates of all 4 legs for individual adjustment on uneven surfaces Pneumatic door controls with foot pedal controller available with an optional hand valve controller 490 mm AVERAGE BURNER EQUIPMENT DEPTH Working Height 935mm 2070mm Shipping ISPM 5 Heat treated export crates Length 2090mm 755mm Width Height Weight 690mm 2080mm 2200KG 595 mm ELECTRICAL BOX 250 mm Please note you will require a minimum of metre clearance around the furnace. * Dimensions are approximate only and may vary slightly with each furnace.

3 50/84 Place Fusion Furnace Natural Gas 240V FAS-20-NG This furnace has a fan forced dual burner system, with an automatic ignition system. It can be swapped between NG and LPG (propane) to suit varying site requirements, with just a few simple adjustments performed on-site involving a minimum of downtime and associated costs. Temperature is monitored and modulated automatically by a Type K thermocouple system and Omron temperature controller, pre-set for a maximum temperature of 200 degrees Celsius. This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual temperature as well as the temperature the furnace is set to. The door has a pneumatic ram opening system with an easy to use foot pedal control. 240V Gas Consumption Natural Gas or LPG 540MJ Per Hour 3.5 KPA Gas Pressure Requirements Minimum Inlet Pressure Maximum Inlet Pressure 3.5KPA 7KPA Low Gas Pressure Detection Air Pressure Switch CPI Switch

4 50/84 Place Fusion Furnace Natural Gas/LPG 0V- FAS-20-NGLPG This furnace has a fan forced dual burner system, with an automatic ignition system. It can be swapped between NG and LPG (propane) to suit varying site requirements, with just a few simple adjustments performed on-site involving a minimum of downtime and associated costs. Temperature is monitored and modulated automatically by a Type K thermocouple system and Omron temperature controller, pre-set for a maximum temperature of 200 degrees Celsius. This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual temperature as well as the temperature the furnace is set to. The door has a pneumatic ram opening system with an easy to use foot pedal control. 0V Gas Consumption Gas Pressure Requirements Minimum Inlet Pressure Maximum Inlet Pressure.5 Natural Gas or LPG 540MJ Per Hour 3.5 KPA 3.5KPA 7KPA Low Gas Pressure Detection High Gas Pressure Detection (Optional) Air Pressure Switch CPI Switch Over Temperature Controller (Optional)

5 50/84 Place Fusion Furnace LPG - FAS-20-LPG This furnace has a dual Long Pattern Inspirator burner system, with an automatic Ignition System. Temperature is monitored and modulated automatically by a Type K thermocouple system and Omron temperature controller, pre-set for a maximum temperature of 200 degrees Celsius. This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual temperature as well as the temperature the furnace is set to. The door has a pneumatic ram opening system with an easy to use foot pedal control. Please note: this type of equipment is not suitable for altitudes above 000 metres and may not be suitable for some countries due to gas regulations. Refer to FAS-0-NG and FAS-0-NGLPG for LPG fuelled system suitable for high altitudes and accepted globally. 240V Gas Consumption LPG (Propane) 540MJ Per Hour 40KPA Gas Pressure Requirements Minimum Inlet Pressure Maximum Inlet Pressure 0KPA 40KPA Door Switch

6 50/84 Place Fusion Furnace Oil (Diesel) - FAS-20-OIL This furnace has a fan forced dual burner system, with an automatic Ignition System. Temperature is monitored and modulated automatically by a Type K thermocouple system and Omron temperature controller, pre-set for a maximum temperature of 200 degrees Celsius. This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual temperature as well as the temperature the furnace is set to. The door has a pneumatic ram opening system with an easy to use foot pedal control. 240V Pilot Burner Fuel Oil/Diesel LPG Small Gas Bottle High Fire Low Fire 80 PSI 70PSI Air Pressure Switch

SIOUX HYBRID WATER HEATER

SIOUX HYBRID WATER HEATER SIOUX Hybrid Water Heater for the Concrete Industry SIOUX HYBRID WATER HEATER Patent Pending Maximizing the Benefits of Coil and Direct-Fired Heating Technologies Higher Discharge Temperature True High-Efficiency

More information

SIMPLIFIED BOILER START UP METHOD FOR FLUIDISED BED COMBUSTION BOILERS

SIMPLIFIED BOILER START UP METHOD FOR FLUIDISED BED COMBUSTION BOILERS SIMPLIFIED BOILER START UP METHOD FOR FLUIDISED BED COMBUSTION BOILERS 1.0 SYNOPSIS The start up of fluidised bed combustion boilers has always been a subject of the most difficult operation. Many boiler

More information

GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER

GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

Rheem Spare Parts Manual. Commercial gas model A631265 Exterior 265L

Rheem Spare Parts Manual. Commercial gas model A631265 Exterior 265L Commercial gas model A631265 Exterior 265L Commercial gas model A631265 Exterior 265L Item Part No. Description 1 221735 Foam cover 2 221914 Anode x 3 (black) 1153mm 2 221924 Anode x 3 (blue) 1153mm 3

More information

Heating with wood chips and pellets

Heating with wood chips and pellets YOUR RELIABLE PARTNER Heating with wood chips and pellets Present on the market 110 for over years 90-150 Advantages of the HERZ firematic boiler User friendly with: Easy operation Automatic cleaning system

More information

Boiler Preparation, Start-Up and Shutdown

Boiler Preparation, Start-Up and Shutdown Boiler Preparation, Start-Up and Shutdown Learning Outcome When you complete this module you will be able to: Describe the basic preparation of a boiler for start-up, and the start-up and shutdown procedures.

More information

OilonChooser Operating Instructions

OilonChooser Operating Instructions OilonChooser Operating Instructions 1. Menu display and structure OilonChooser s menu display shows the data input field in the central area. The navigation bar is located in the left column. It shows

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

ETC -SV. Class 0 oil-free compressed air through catalysis

ETC -SV. Class 0 oil-free compressed air through catalysis Innovation QUALITy Reliability Worldwide ETC -SV Class 0 oil-free compressed air through catalysis The way to oil-free compressed air The ETC operating principle Through the process of catalytic oxidation,

More information

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil. Lanair Clean Burn CABINET Lanair's lightweight heat exchanger provides very little travel for the heat to be picked-up and ultimately be transferred to your shop. It uses a 2-pass design made up of 12

More information

Please keep this manual for f uture reference.

Please keep this manual for f uture reference. GAS WATER/AGUA Congratulations! You've just purchased a new Marey Portable tankless water heater and will soon begin to enjoy the benefits of going tankless. Take the time to thoroughly read and understand

More information

Air Conditioning Sign-Off Sheet

Air Conditioning Sign-Off Sheet Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate

More information

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers Peerless Boilers Series GM Residential/Commercial Gas Boilers The Series GM cast iron, hot water boiler is ideal for use in large residences or commercial applications. This gas-fired, atmospheric boiler

More information

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS RHEEM CONTINUOUS FLOW GAS HOT WATER REVISED MAY 2013 GAS 6 ENERGY RATING 1-6 PERSONS 12-54 L/MIN CAPACITY 10 YEAR WARRANTY 3 NOW 6 STAR EFFICIENT HOT WATER THAT NEVER RUNS OUT factor COMES ON STEADY, HOT

More information

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease The NEW Greenstar i innovative intuitive improved performance installation ease A NEW look, NEW features and a NEW NAME for the UK s best selling boiler, the Greenstar i Junior 1 Introducing the new Greenstar

More information

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08 Air Volume Requirement Air conditioning systems are engineered with a specific amount of indoor air passing across the surface of the evaporator coil. The amount of air is measured in cubic feet per minute.

More information

Installation Instructions

Installation Instructions GC 3 (THREE OVEN) Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require.

More information

Heating and cooling a home in Australia amounts to around

Heating and cooling a home in Australia amounts to around Heating and cooling a home in Australia amounts to around 23% of household energy use, second to only hot water. Gas is one of the most greenhouse friendly fuel sources available and selection of a Rinnai

More information

Endless Hot Water 24/7

Endless Hot Water 24/7 Endless Hot Water 24/7 Chromagen Continuous Flow Gas Water Heaters Live in eternal comfort with endless, efficient hot water from Eternity Get hot water on demand with an Eternity continuous flow gas water

More information

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System TECHNICAL SPECIFICATION StirLIN-1 Economy Liquid Nitrogen System Reference 80 8120_01 Issue Date August 1, 2015 1. INTRODUCTION Since more than sixty years Stirling Cryogenics has designed and manufactured

More information

Gas Fireplaces FEATURING

Gas Fireplaces FEATURING Gas Fireplaces FEATURING Product Overview PRODUCT SPECS MODEL 564 GS2 (Clean Face) Dancing-Fyre Ember-Fyre Diamond-Fyre 864 GS2 (Clean Face) 864ST GS2 Mj Input High - NG/LPG 21.6 35 35 35 31 39.5 Low NG

More information

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...

More information

Gas Detection for Refining. HA University

Gas Detection for Refining. HA University Gas Detection for Refining HA University Refinery Process and Detection Needs Refining i Crude Oil Final Products Coke Asphalt Waxes, Lubricating Oils and Greases Kerosene, Jet Fuel, Diesel Fuel, Home

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

301.7D. Mini Hydraulic Excavator

301.7D. Mini Hydraulic Excavator 301.7D Mini Hydraulic Excavator Engine Weights Gross Power (ISO 14396) 17.9 kw 24.3 hp Operating Weight with Canopy 1610 kg 3,550 lb Net Power 13.2 kw 17.7 hp Operating Weight with Cab 1720 kg 3,792 lb

More information

AUTOMATIC LPG BOOKING, LEAKAGE DETECTION AND A REAL TIME LPG MEASUREMENT MONITORING SYSTEM

AUTOMATIC LPG BOOKING, LEAKAGE DETECTION AND A REAL TIME LPG MEASUREMENT MONITORING SYSTEM AUTOMATIC LPG BOOKING, LEAKAGE DETECTION AND A REAL TIME LPG MEASUREMENT MONITORING SYSTEM R.Padmapriya, E.Kamini, priyaece973@gmail.com,kamsenpa007@gmail.com, IV Year Electronics and Communication Engineering,

More information

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email sales@morcoproducts.co.uk Web www.morcoproducts.co.uk Retrofit or Upgrade a Water Heater in a Caravan

More information

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR The heat transfer innovators. THE RELIANCE COPPER FINNED TUBE HYDRONIC BOILER FEATURES Copper Fin-Tube Heat Exchanger Up to 88% Thermal

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600

More information

www.optimumheat.co.uk

www.optimumheat.co.uk The modern wood pellet boiler with built-in flexibility and remote fingertip control Up to 98% efficient Wide output range Simple touch-panel control Remote control & maintenance Extremly low emissions

More information

Product Overview Benefits

Product Overview Benefits Trade Data CP CP Upright / CP Horizontal / CP Counterflow / CP EA External Heaters and Fired Warm Air Heaters Heat Outputs from 26kW - 586kW Issue 1.02 Print 2 ay 2011 Product Overview Benefits Installer

More information

Rainwater Harvesting

Rainwater Harvesting Rainwater Harvesting With climate change now a reality rather than a speculated possibility, the demand on water resources has gone up, whilst the amount of water available for supply has gone down. Forth

More information

Instantaneous gas water heater

Instantaneous gas water heater Instantaneous gas water heater Models W 125...T1 installation operation maintenance The Bosch instantaneous water heater is a high efficiency, space saving answer to your water heating needs. All Bosch

More information

San josé OWNER S MANUAL

San josé OWNER S MANUAL San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.

More information

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This

More information

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series The range of E-Pro cold units includes various types of refrigerated units and worktops. Thanks to the flexible

More information

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities Device Charts For Oil and Gas Handling and Production Facilities Purpose/Scope: The purpose of this document is to provide standardized guidance for use by the regulated community and air permit reviewers,

More information

11,000 kg, 13,000 kg, 16,000 kg Diesel, Pneumatic Tire

11,000 kg, 13,000 kg, 16,000 kg Diesel, Pneumatic Tire R Pneumatic Diesel Forklift Trucks D110/130/160S-5 11,000kg to 16,000kg Capacity D110 / 130 / 160S-5 11,000 kg, 13,000 kg, 16,000 kg Diesel, Pneumatic Tire Printed in Repubic of Korea PSC2604D0(Feb.2007)

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB, TUD2B080A9V3VB TUD2C080A9V4VB, TUD2C080B9V4VB TUD2B00A9V3VB, TUD2C00A9V5VB TUD2C00B9V5VB, TUD2DA9V5VB TUD2DB9V5VB, TUD2DA9V5VB

More information

Practical Examples of Heat Regenerative System at Steelmaking Works

Practical Examples of Heat Regenerative System at Steelmaking Works 2nd India-Japan Energy Forum Practical Examples of Heat Regenerative System at Steelmaking Works On Monday 4 February 2008 in Delhi Nisshin Steel Co., Ltd. Yukio Tomita 1 Structure of the Regenerative

More information

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

A reasonable, new furnace (mid efficiency) has the following electrical requirements: June 2007 Power Backup Systems for Your Home. As promised from a previous safety meeting, a couple of options to protect you home in the event of a power failure. These options are for the most serious,

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

Midland Combustion Electric Line Heaters with Integral Panels

Midland Combustion Electric Line Heaters with Integral Panels Midcom Electric Line Heaters are available to work with even the most difficult oils and process fluids when there is no other heating medium available. High viscosity crude oils as well as coal tar, bitumen,

More information

Donut Robot Mark I Mark VI

Donut Robot Mark I Mark VI The worldwide leader in donut production equipment +1.206.322.5474 info@belshaw.com www.belshaw.com AUTOMATIC FRYERS Donut Robot Mark I Mark VI Donut Robot Series Automatic Fryers deposit, fry, turn, and

More information

AMS 120. EFT Guest Card Terminal & Refund unit

AMS 120. EFT Guest Card Terminal & Refund unit AMS 120 EFT Guest Card Terminal & Refund unit ACCOUNT MANAGEMENT STATIONS Wall mounted kiosk offering Visitor card purchase and refund Card deposit EFT purchase, refund and loading Full statement facilities

More information

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44. FORM NO. O11-608 REV. 2 Supersedes Form No. O11-608 Rev. 1 OIL FURNACES CLASSIC PREMIUM CLASS UPF OIL FURNACES ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.30 kw] The Rheem Classic

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable

More information

N o.11. engineering BOX OVENS OVENS OVENS OVENS OVENS. The definitive guide to industrial ovens MINI WALK IN EXTRA HEIGHT TUNNEL CONVEYOR.

N o.11. engineering BOX OVENS OVENS OVENS OVENS OVENS. The definitive guide to industrial ovens MINI WALK IN EXTRA HEIGHT TUNNEL CONVEYOR. OVEN PRICE GUIDE engineering N o. UK s N o.11 industrial ovens manufacturer MINI FEBRUARY 2012 BOX WALK IN EXTRA HEIGHT TUNNEL CONVEYOR RDM ENGINEERING Stakehill Lane, Stakehill, Middleton Manchester M24

More information

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following

More information

Flash Point. www.koehlerinstrument.com. Test Methods

Flash Point. www.koehlerinstrument.com. Test Methods Flash Point s Page Flash Point by Automatic Pensky-Martens Closed Tester ASTM D93; IP 34; ISO 2719; DIN EN 22719; NF M 07-019; JIS K2265...32 Flash Point by Automatic Abel Tester IP 170, 304; ISO 1523,

More information

REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED)

REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED) REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED) MODELS 0, 80, 00, 20 PARTS LIST AUGUST 202 A REDFYRE CENTRAL HEATING COOKER ---- TOP - PLATE & LIDS 2 REDFYRE CENTRAL HEATING COOKER ---- TOP - PLATE &

More information

Gas Water Heater. Coming into Its Own, Finally COMPARATIVE TEST

Gas Water Heater. Coming into Its Own, Finally COMPARATIVE TEST COMPARATIVE TEST Gas Water Heater Coming into Its Own, Finally Its relatively lower operating cost and convenience of use have ensured for the instantaneous gas water heater (IGWH) a steadily increasing

More information

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon) (IFGS) SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon) (This appendix is informative and is not part of the code. This appendix is an excerpt from the 2006 International Fuel Gas

More information

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING. INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS PROPANE GAS ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY. GAS LOGS MUST BE INSTALLED BY PERSONNEL QUALIFIED FOR INSTALLING GAS APPLIANCES.

More information

mobile pipeline Bulk transportation and storage of energy gases

mobile pipeline Bulk transportation and storage of energy gases mobile pipeline Bulk transportation and storage of energy gases 1 An advanced pipeline to supply energy gases over long distances at competitive costs capacity matters Your mobile pipeline In 2006, Hexagon

More information

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Technical Specification. Generating Set with Waukesha engine burning natural gas

Technical Specification. Generating Set with Waukesha engine burning natural gas Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the

More information

COMMERCIAL GAS DRYER FUELLED BY TOWN GAS CODE OF PRACTICE GU13 (MODULE ONE)

COMMERCIAL GAS DRYER FUELLED BY TOWN GAS CODE OF PRACTICE GU13 (MODULE ONE) COMMERCIAL GAS DRYER FUELLED BY TOWN GAS CODE OF PRACTICE GU13 (MODULE ONE) August 2007 Issue 2 Table of Contents 1. Foreword and Scope...1 2. Terminology...3 3. General...5 4. Gas Meter...6 5. Pipe Connection

More information

4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm

4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm The Perkins 4000 Series family of 6, 8, 12 and 16 cylinder diesel engines was designed in advance of today s uncompromising demands within the power generation industry and includes superior performance

More information

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts; 1/11 CO2 DOSAGE SYSTEMS CO2 dosage system consists of following parts; 1 - O2 trim system with micro processing burner (automatic combustion monitoring), 2 - Other components of O2 trim system, 3 - CO2

More information

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS Remember, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

Automation's Modular Containerized Datacenter Solutions

Automation's Modular Containerized Datacenter Solutions SAFE Automation's Modular Containerized Datacenter Solutions Automation's SAFE (Secure, Autonomous, Flexible, Efficient) Modular Containerized Datacenter offers a fast, flexible and efficient solution

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

G670 Intermittent Pilot Ignition Controls

G670 Intermittent Pilot Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control

More information

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

- mark gas burners Cuenotherm NC.4 - NC.6 - NC.9 14.5-90kW.

- mark gas burners Cuenotherm NC.4 - NC.6 - NC.9 14.5-90kW. - mark gas burners Cuenotherm NC.4 - NC.6 - NC.9 14.5-9kW. Low NO x Comprehensive control panel Gas rack Low NOx combustion head Strong light alloy pressuremoulded housing Electronic ignition transformer

More information

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district PLANT TORINO NORD Iren Energia is the company in the Iren Group whose core businesses are the production and distribution of electricity, the production and distribution of thermal energy for district

More information

Inventory Management Guide

Inventory Management Guide NORTH/NORTHWEST Inventory Management Guide Honeywell Residential Combustion is the industry leader in combustion controls for applications including warm air furnaces, boilers, commercial water heaters,

More information

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER Installation and service must be performed by a qualified service installer, service agency or the gas supplier. Oil Gas/Oil

More information

MODELS BTR(C)120 THRU 500A

MODELS BTR(C)120 THRU 500A MODELS BTR(C)120 THRU 500A COMMERCIAL GAS, GLASS-LINED, TANK-TYPE WATER HEATER INSTALLATION OPERATION MAINTENANCE LIMITED WARRANTY Thank you for buying this energy efficient water heater from A.O. Smith

More information

Autoclave Design Considerations

Autoclave Design Considerations Autoclave Design Considerations Most composite manufacturing personnel are familiar with autoclave processing and understand basic autoclave operating principles. The autoclave is considered the most robust

More information

Access Server Rack Cabinet Compatibility Guide

Access Server Rack Cabinet Compatibility Guide Access Server Rack Cabinet Compatibility Guide A Guide to the Selection and Evaluation of Access Server Rack Cabinets for Compatibility and Use with Third Party Server Chassis Kalkenstraat 91-93 B-8800

More information

SPIDERfire: Delivers high efficiency and real savings for today s businesses

SPIDERfire: Delivers high efficiency and real savings for today s businesses Product Brochure Commercial Water Heaters SPIDERfire Series SPIDERfire: Delivers high efficiency and real savings for today s businesses Up to 97% thermal efficiency 80 and 100-gallon capacity models Patented

More information

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design BRYAN FLEXIBLE WATER TUBE AB SERIES STEAM AND WATER BOILER 900,000 TO 3,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Water Boiler AB120-W-FDGO Steam Boiler AB250-S-150-FDG Originators of the Flexible

More information

Gas and Oil Fired Space Heating

Gas and Oil Fired Space Heating January 2012 Country of Origin: United Kingdom Gas and Oil Fired Space Heating Section 1 Fixed Installations...2 Introduction...2 1. Location of Heater...2 2. Automatic Controls...2 3. Fuel Supply Gas

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

Effect of Self-Heat Circulation on VOCs Decomposition in Regenerative Thermal Oxidizer

Effect of Self-Heat Circulation on VOCs Decomposition in Regenerative Thermal Oxidizer Effect of Self- Circulation on VOCs Decomposition in Regenerative Thermal Oxidizer Shinsuke Iijima 1, Katsuya Nakayama 1, Koichi Ushiroebisu 1 Mitsuhiro Kubota 2 and Hitoki Matsuda 2 1. Engineering Division,

More information

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING CALIFORNIA RESIDENTIAL CODE MATRIX ADOPTION TABLE APPENDIX A SIZING AND CAPACITIES OF GAS PIPING (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state

More information

DUAL FUEL BURNERS GAS/HEAVY OIL

DUAL FUEL BURNERS GAS/HEAVY OIL M A D E I N I TA LY SERIE KN 750/M_1000/M EL DUAL FUEL BURNERS GAS/HEAVY OIL BRUCIATORI MISTI GAS/OLIO COMBUSTIBILE All purpose heating solutions Soluzioni integrate per il riscaldamento All purpose heating

More information

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50

More information

Pneumatic Forklift Trucks D15G / D18G G15G / G18G. 1,500kg to 1,750kg Capacity

Pneumatic Forklift Trucks D15G / D18G G15G / G18G. 1,500kg to 1,750kg Capacity Pneumatic Forklift Trucks D15G / D18G G15G / G18G 1,500kg to 1,750kg Capacity Improve your Material Handling Performance with DOOSAN Forklifts! High Performance, Great Productivity, Energy Efficient, Superior

More information

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE? WHAT IS A BTU? The standard energy measurement is the BTU (British Thermal Unit). Each BTU unit is determined by the amount of thermal energy required to raise the temperature of one pound of water by

More information

01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09

01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09 0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by

More information

C18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm

C18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression

More information

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved. Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual

More information

Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB

Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB Gas Fired Cookers Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB FOR USE IN GB & IE PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING YOUR AGA Consumer Protection As responsible

More information

GenStore Archive Cabinet

GenStore Archive Cabinet GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4

More information

FORKLIFT STABILITY. MATERIAL HANDING AND ROBOTICS I. Practical course. Dávid HURI office door number: 324/6 huri.david@eng.unideb.

FORKLIFT STABILITY. MATERIAL HANDING AND ROBOTICS I. Practical course. Dávid HURI office door number: 324/6 huri.david@eng.unideb. FORKLIFT STABILITY MATERIAL HANDING AND ROBOTICS I. Practical course Dávid HURI office door number: 324/6 huri.david@eng.unideb.hu What is a powered industrial truck (P.I.T.)? Definition: A powered vehicle

More information

Automatic Back-Flushing Filter AutoFilt RF9.

Automatic Back-Flushing Filter AutoFilt RF9. Automatic Back-Flushing Filter AutoFilt RF9. AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

EM 58. 19. REMOVE NO. 2 MANIFOLD STAY (a) Remove the bolt, nut and stay.

EM 58. 19. REMOVE NO. 2 MANIFOLD STAY (a) Remove the bolt, nut and stay. 57 ROVAL 1. DISCHARGE FUEL SYST PRESSURE (See page FU-9) 2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery

More information

REPORT NUMBER: 100758576MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

REPORT NUMBER: 100758576MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012 TEST REPORT REPORT NUMBER: 100758576MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012 EVALUATION CENTER Intertek Testing Services NA Inc. 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Fire Door Caulk LLC.

More information

PREPIPED LIQUID FUEL MANIFOLDS PLPM

PREPIPED LIQUID FUEL MANIFOLDS PLPM PREPIPED LIQUID FUEL MANIFOLDS PLPM INSTRUCTIONS WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components,

More information

INSTANTANEOUS GAS FIRED

INSTANTANEOUS GAS FIRED INSTANTANEOUS GAS FIRED Celt Star C Britony II T Britony FlexiFlue Hot water on demand Instantaneous gas fired water heaters Instant hot water from the world leader Back in 1925 Chaffoteaux & Maury invented

More information

Split units TH with hermetic compressors

Split units TH with hermetic compressors Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split

More information