MODELS VA3B, VB5B VC5B
|
|
- Antony Edwards
- 7 years ago
- Views:
Transcription
1 Thi d t t d ith F M k Heating & Cooling HEAT RECOVERY VENTILATORS MODELS VA3B, VB5B VC5B VA3B VB5B The Heat Recovery Ventilation (HRV) system offered by BDP is the finest unit on the market today. The VA3B, VB5B, and VC5B provide efficient and cost-effective heat recovery during the heating season when needed most. As temperatures drop below 23 F ( 5 C), indoor air is recirculated periodically through the heat exchanger core to prevent frost from forming. Competitors methods of supplementary electric defrost waste energy. Unlike rotary wheel heat exchangers which mix airstreams, these cross-flow or counter-flow heat exchangers ensure that there is no mixing of the stale airstream with the fresh outdoor airstream. A filter installed on the incoming outdoor air stream removes large airborne particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required. The units acoustically engineered design makes them the quietest on the market and ensures that comfort is felt, not heard. Unlatching 2 suitcase style latches allows easy removal of the filters and core for cleaning. VC5B Form No. PDS VA3B.15.1P
2 FEATURES Energy saving defrost cycle Cross-flow, counter-flow heat exchangers Two filters on incoming outdoor air stream to protect the HRV core Acoustical design No-tools maintenance MODEL NUMBER NOMENCLATURE V A 3 B A B 015 A B Second Series 3 Horizontal 5 Upflow/Downflow A Conventional (RNC) B Compact (Standard) C High Efficiency (Deluxe) V Heat Recovery Ventilator B Defrost Maximum Capacity (cfm) 015 (150 cfm) 020 (200 cfm) 027 (270 cfm) TESTED/CERTIFIED AN INDEPENDENT LABORATORY TESTING FOR PUBLIC SAFETY HOME VENTILATING INSTITUTE DIVISION OF AMCA 2
3 CONTROLS AND ACCESSORIES PART NO. NOMENCLATURE K V B CN PAU K Accessory Kit AC Accerssory CN Control FL Filter Media TM Timer A Original Series B Second Series V Heat Recovery Ventilator (HRV) 01 Part Number 01 Single Pack CONTROL DESCRIPTION (B SERIES) PAU BDP Automatic Control (VB5B and VC5B only) PBS BDP Basic Control PST BDP Standard Control ACCESSORY DESCRIPTION (A SERIES) 6FM 6 in. Flowmeters (2) 7FM 7 in. Flowmeters (2) 8FM 8 in. Flowmeters (2) EXH Exhaust Hood HOD Intake Hood KIT Balancing Kit FIR Furnace Interlock Relay (A SERIES) TIMER DESCRIPTION 20M 20-Minute Timer Kit Non-Branded (B SERIES) 20B 20-Minute Timer Kit BDP (A SERIES) 60M 60-Minute Adjustable Timer Kit (A SERIES) FILTER DESCRIPTION (A SERIES) /2 x 12-3/ /8 x 16-5/ /16 x 13-1/ /8 x 15-1/ /16 x 13-1/ /8 x 10-3/ /8 x 12-3/ x 16-5/8 3
4 (596.9) DIA (191.0) G (120.6) DIA (148.9) 1 (25.4) (74.6) (56.2) 4 PLCS (17.5) DIA (148.9) (58.7) (61.9) K DIA (148.9) DIA (191.0) F E (425.4) 20 (508.0) (460.4) (428.6) 15 (381.0) (148.9) D C B A 5 16 (7.9) 3 8 (9.5) H (768.3) (27.0) (17.5) 1 2 (11.9) (41.3) 7 8 (22.2) (31.7) J 3 4 (19.0) 3 8 DIA (9.5) A92274 DIMENSIONS A B C D E F G H J K MODEL NO. In. mm In. mm In. mm In. mm In. mm In. mm In. mm In. mm In. mm In. mm VA3BAB / / / / / / / / / / VA3BAB / / / / / / / /
5 [115.9)] DIA [191.0] DIA [148.9] H DIA 3 4 [19.0] 7 16 DIA [11.2] 7 8 DIA [22.2] 3 8 DIA [22.2] E [80.2] D [74.6] [146.0] 1 [25.4] F [500.8] [48.4] [56.2] 4 PLACES [61.9] 2 PLACES [105.6] [553.2] 27 [658.8] [521.3] C A B [56.4] 3 8 [9.5] 21 [533.4] [397.7] [16.7] DIA. [17.5] [66.7] 3 4 [19.1] G A92275 DIMENSIONS A B C D E F G H MODEL NO. In. mm In. mm In. mm In. mm In. mm In. mm In. mm In. mm VB5BAB / / / / / / / / VB5BAB020 VC5BAB / / / / / / / /
6 1 1 2 [38.1] [551.9] [610.6] DIA [206.4] DIA (191.0) DIA [148.9] [74.6] 3 PLCS 37 [940.6] (1085.9) [505.6] [70.7) ]3 4 [19.1] 3 8 [9.5] [484.7] [208.5] [445.4] [147.8] [120.6] [394.5] [464.4] 1 [25.4] [175.9] [55.5] [61.9] 3 PLCS [935.0] [506.4] [282.6] [587.4] [16.7] [77.8] DIA. [17.5] [181.8] VC5BAB020 VC5BAB [604.3] [568.3] [29.3] [181.0] [1035.1] 7 8 DIA. [22.2] 3 4 [19.1] A
7 NOTE: Consult design manual for proper selection of unit. SPECIFICATIONS MODEL CONVENTIONAL COMPACT HIGH EFFICIENCY VA3BAB015 VA3BAB020 VB5BAB015 VB5BAB020 VC5BAB015 VC5BAB020 VC5BAB027 Capacity - cfm l/s Port Locations Top and Sides Top and Sides Top Top Top Top Top Heat Core Cross Cross Cross Cross Cross Counter Counter Type Weight 60 lb (27 kg) 80 lb (36.6 kg) 60 lb (27 kg) 80 lb (36.3 kg) 80 lb (36.3 kg) 120 lb (54.5 kg) 120 lb (54.5 kg) Shipping Wt 67 lb (30.4 kg) 85 lb (38.5 kg) 75 lb (34 kg) 89 lb (40.4 kg) 89 lb (40.4 kg) 143 lb (64.9 kg) 143 lb (64.9 kg) Shipping Dim. (in.) Height Width Depth AIRFLOW PERFORMANCE Capacity - cfm l/s Efficiency 32 F (0 C) 13 F ( 25 C) Heat Core Exchange Area % 56% % 61% % 60% % 67% % 66% % 72% ft ft 2 90 ft ft ft ft ft m m m m m m m 2 ELECTRICAL DATA Voltage 120v 120v 120v 120v 120v 120v 120v Max Power 105w 216w 115w 196w 120w 250w 520w Max Amps 1.2a 2.0a 1.2a 1.8a 1.2a 2.5a 4.6a 80% 74% 7
8 ACCESSORIES DESCRIPTION AND USAGE Push Button Timer Enables the unit to override mode selected and operate at high speed for 20 minutes. Ideal for special activity areas such as bathrooms or kitchens where high-speed exhaust is needed for short periods of time. Kit includes 12 wall-mounted timers and a control unit (12v). 60-Minute Timer Allows the user to override current operation mode and operate at high speed. Adjustable from 10 to 60 minutes with an additional 20 minutes added from the control board. Ideal for areas requiring high-speed exhaust for longer periods of time (12v). Balancing Kit Installers tool complete with: 1 Magnahelix gage (0 2.5-in. H 2 O), 2 6-in. diameter flowmeters, 4 pieces of plastic hose and instructions. Packaged in a metal tool box, this kit contains all the instruments needed to balance a HRV installation. CONTROL FEATURES Basic Control: Allows the user to manually set fan speed to low or high as required to maximize comfort. Standard Control: Offers automatic dehumidistat control and the option to select continuous or intermittent fan operation. Automatic Control: In addition to features found with the standard control, this package offers a recirculation mode and an air ionizer. This control may be used with stand alone versions of the VB5B and VC5B only. CONTROL DESCRIPTION FAN SPEED CONTROL DEHUMIDISTAT CONTROL CONTINUOUS MODE* INTERMITTENT MODE* CIRCULATION MODE AIR IONIZER Basic Yes No Yes No No No Standard Yes Yes Yes Yes No No Automatic Yes Yes Yes Yes Yes Yes * Air exchange with outside. No air exchange with outside. Use only on units with defrost. CONTROL DESCRIPTION AND USAGE Fan Speed Control Enables user to modulate fan speed from low to high air exchange with outside. Dehumidistat Control Allows the user to select the relative humidity level at which the unit would change fan speed for dehumidification in the winter months. Continuous Mode If the relative humidity inside the building is lower than selected, air exchange occurs with the outside air at low speed. If the relative humidity inside the house is higher than selected, air exchange occurs with the outside air at high speed. Ensures continuous air exchange for constant air quality. Intermittent Mode If the relative humidity inside the building is lower than selected, no air exchange occurs and the system turns off. If the relative humidity inside the house is higher than selected, air exchange occurs with the outside at high speed. Ensures minimum air exchange level when the building is unoccupied to minimize operating costs. Circulation Mode If the relative humidity inside the building is lower than selected, the ambient air is circulated and filtered at high speed. If the relative humidity inside the house is higher than selected, air exchange occurs with the outside air at high speed. Ensures continuous movement and filtration of air for maximum comfort. Available with automatic control only. Air Ionizer Neutralizes airborn particulates by negatively charging them. For use on independently installed systems with automatic controls only. 8
9 AUTOMATIC DEFROST CYCLE FEATURES All models offer a non-electric defrost cycle feature which prevents frost and ice buildup within the heat recovery core. It should be specified for areas where winter design temperatures are lower than 32 F/0 C. When the outside air temperature falls below 23 F/ 5 C it is electronically sensed and the dampers close the outside air ports. This allows warm indoor air to recirculate within the heat recovery core. The frequency of this cycle increases as the outside air temperature decreases. This option must be specified at the time of purchase of the original equipment, and is not field retrofittable. MODEL 23 F TO 5 F ( 5 C TO 15 C) 5 F TO 22 F ( 15 C TO 30 C) BELOW 22 F ( 30 C) PREFIX DEFROST EXCHANGE DEFROST EXCHANGE DEFROST EXCHANGE VA3BAB 5 Minutes 60 Minutes 5 Minutes 35 Minutes 5 Minutes 20 Minutes VB5BAB 5 Minutes 60 Minutes 5 Minutes 35 Minutes 5 Minutes 20 Minutes VC5BAB 6 Minutes 60 Minutes 5 Minutes 35 Minutes 6 Minutes 20 Minutes 9
10 HRV INSTALLED WITH FORCED AIR SYSTEM A92361 HRV INSTALLED WITH INDEPENDENT AIR DISTRIBUTION A92360 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Heating & Cooling Cancels: New 1995 BDP Co. Indpls, IN PRINTED IN U.S.A. 10 Catalog No VA-3B1P 3-95
Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H
HR SERIES HEAT RECOVERY VENTILATOR (HRV) Home Owners Guide Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR100V HR160H & HR220H READ AND SAVE THIS GUIDE PP0924 09/2013 ABOUT S&P S&P is the world's
More informationOperation and Installation Manual. Max Series
Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat
More informationUSER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY
USER MANUAL RESIDENTIAL USE ONLY VB0175 HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY GUIDELINES SET BY NATURAL RESOURCES CANADA
More informationInnovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
More informationwarm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.
Lifebreath delivers a complete indoor climate control package Indoor comfort in a small package The patented Lifebreath Clean Air Furnace combines the fresh air benefits of the Heat Recovery Ventilator
More informationZehnder Focus 200. Ventilation device
Ventilation device Use The Zehnder Focus (F) 200 comfort ventilation unit was specially developed for use in demanding residential and commercial buildings. It combines maximum comfort, simple operation
More informationHRV and ERV Best Practices. December 18, 2012 Portland Metro Home Builders Association
HRV and ERV Best Practices December 18, 2012 Portland Metro Home Builders Association The Basics: The X Flow Ports Connected to Inside 72 F 61 F 42 F 32 F Ports Connected to Outside The Single Most Important
More informationHEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV
USER GUIDE HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV PLEASE READ AND SAVE THESE INSTRUCTIONS These products earned the ENERGY STAR
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
More informationCombi Unit Genius. The energy efficient Building Service Centre
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Combi Unit Genius The energy efficient Building Service Centre systemair Central Building Services
More informationNew Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
More informationNewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
More informationVentilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech
Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling 2 Ductless Ventilation & Fresh Air Solutions We can fill your home with healthy, fresh air Indoor Air Pollution is real, and it
More informationKSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle
KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW
More informationRKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
More informationyork air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
More informationCE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
More informationDUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing
More informationIndoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY
Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. QUALITY AIR STARTS HERE. AccuExchange Energy Recovery Ventilator Improve your home s indoor environment by exchanging stale
More informationLow Cost. Lower Energy Costs. Higher Efficiency.
HI-E DRY dehumidifiers remove two to three times more water per kilowatt hour of electricity than conventional dehumidifiers. Low Cost. Lower Energy Costs. Higher Efficiency. Therma-Stor designed an efficient,
More informationThe High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
More informationFilterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000
Filterfans Patented Click & Fit design provides a hardware free installation! Poured-in foam gasket allows for quick NEMA 12 sealing against the enclosure (except PF 1000) Plastic made from strong (ABS-FR),
More information26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.
T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R
More informationNewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
More informationPool Dehumidification Basics
Copyright 2009 Wescor. All rights reserved. Permission granted to reproduce for personal and educational use only. When energy costs were low, many pool owners considered only first cost when choosing
More informationfloater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL
floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL WHAT IS AN ECO AIR COOLER? The ECO AIR COOLER uses evaporative cooling to provide an airflow that is cooler than the
More informationF9MXE. Product Specifications
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports
More informationA Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses
A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses Robert L Crosby Jr, Biorealis Systems, Inc. Abstract: Bristol Bay Housing Authority (BBHA) currently
More informationHeat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
More informationG9MXE. Product Specifications
Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)
More informationPortable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
More informationMistrale. Fusion Terminal
Mistrale Fusion Terminal PUBLICATION NATURAL VENT. 1 SEPT 2015 Features - Slimline energy efficient ventilation solution - Standard and high capacity terminals provide 128 or 256 L/s capacity - Compliant
More informationDuplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard
Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard Duplexvent DV72 EC MVHR is designed to provide constant volume ventilation levels to exceed the latest Building Regulations 2010. The
More informationUNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
More informationUnico Inverter. Unique and efficient.
Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationECO-AIR AIR CONDITIONING www.northamericanhvac.com
INDEX ACCESSORIES INSTALLATION... 3-7 LINE SETS... 3-7 GEOTHERMAL... 3-8 WIRING CABLE... 3-8 CIRCULATOR PUMPS (PRO-TECH MODEL)... 3-9 DC INVERTER SINGLE ZONE HEAT PUMP... 3-6 DC INVERTER TECHNOLOGY...
More informationVAV Laboratory Room Airflow The Lowdown on Turndown
Technology Report March, 2003 VAV Laboratory The Lowdown on Turndown Turndown comparison of these two turndown ratios. Note the small actual airflow difference between them. control ranges are normally
More informationHIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons
Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined
More information6 Crankcase Ventilation
6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................
More informationEngineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER
Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER SUMMARY A proper balance of temperature and humidity control is essential for efficient data center operation, and integral
More informationFULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
More informationASTACEA4 Inspect complex/central air conditioning systems
Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air
More informationMovinCool Office Pro Series. The Portable Spot Cooling Solution
MovinCool Office Pro Series The Portable Spot Cooling Solution The Office Pro 2002 American Standard Inc. All rights reserved Losing Is Not An Option With The Office Pro Series. The loss of data and equipment
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED
More informationWALL CONTROLS MAIN CONTROLS
MAIN CONTROLS WALL CONTROLS Due to the constant evolution of our technologies, it may be possible that some control functions are not compatible to some earlier unit models. For more details, please refer
More informationMaterial test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
More informationHow To Order A Direct Flow Air Cleaner
Reduced Volume - Improved Performance - Flexible Packaging The patented Direct Flow technology provides the flexibility to optimize the air system performance to size ratio, meeting the demands of today
More informationImportant Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
More informationNewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters
More informationPRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More informationLiebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
More informationDIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
More informationWeiss Mobile Air Conditioning Systems
Weiss Mobile Air Conditioning Systems SHELTER AIR CONDITIONING System Weiss Umwelttechnik GmbH Simulationsanlagen Messtechnik Worldwide... Weiss Umwelttechnik GmbH is one of the world s most important
More informationENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE
ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce
More informationINDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More informationCommunicating Wall Control Installation Manual TSTAT0101SC
Communicating Wall Control Installation Manual TSTAT0101SC U.S. Patent No. 7,243,004 U.S. Patent No. 7,775,452 616 01 1017 02 08/07/12 Safety Considerations... 7 Introduction... 8 Quick Start... 9 Set
More informationBring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
More informationRRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
More informationDehumidifier D 850E. - Instruction manual version 02
Dehumidifier D 850E - Instruction manual version 02 Content 1. Description of dehumidifier 1.1. General data 1.2. Technical data 2. Operation and usage 2.1. Usage 2.2. Location and installation 2.3. Preparing
More informationEnergy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
More informationFeatures and Benefits. Product Overview. Installation Overview. Sales Strategy Overview FPO
RESCUE EcoTech Direct Drive Blower Motor The High Efficiency ECM/BPM Drop-in Replacement Blower Motor Agenda Features and Benefits Product Overview Installation Overview Sales Strategy Overview FPO High
More informationOWNER S MANUAL VMH 09/12/18/27/36 InverterFlex
OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex Version C Single, Dual, Tri or Quad Zone Ductless Mini-Split System Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com
More informationDIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
More informationINDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES
More informationPortable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
More informationIncubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More informationNEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!
Flexit SL4 R Air Handling Unit with rotating recovery system Energy-efficient New control system NEW! Patent applied for! - Simple settings - Flexible installation - User friendly F O R H E A LT H Y I
More informationSolar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...
Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system
More informationHow To Design A Building In New Delhi
ENERGY EFFICIENT HVAC DESIGN FOR COMPOSITE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce energy consumption
More informationThe compact unit series
The compact unit series The easy way to maintain a good climate i High, efficient energy recovery with an efficiency of 80 90 % i Energy-saving fan motors utilising EC technology for minimal energy consumption
More informationVariable Air Volume - VAV
Mode Enable Sensor Options Variable Air Volume - VAV The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during occupied operation. The following options are available:
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
More informationSWIMMING POOL AIR-HANDLING UNITS KU-DB Series
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =
More informationNews! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment
News! Flexit S20 R Air Handling Unit A new generation of Air Handling Units For a healthy indoor envionment Flexit S20 R Air Handling Unit Flexit is launching a new range of air handling units with capacity
More informationSamsung Room Air Conditioning
Samsung Room Air Conditioning Air Conditioning Solutions from a Trusted Brand At the heart of family living is the home, a place full of special moments and wonderful memories where families live and
More informationLyoBeta. R+D Freeze-Dryers
LyoBeta R+D Freeze-Dryers LyoBeta series A Responsible Choice New demands in R+D centers are related to scale-up feasibility and quality of procedures and research methods. FDA investigators consider that
More informationHow To Get A Passive House
Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2015 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Product
More informationFlexit air handling unit K2 R
Flexit air handling unit K2 R with integrated kitchen hood PATENTED The quietest on the market Modern design Energy-efficient Installation in the kitchen A FOR A HEALTHY ENVIRONMENT Requirement-controlled
More informationMULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS
MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS POER, FLEXIBILITY, RESIDENTIAL Carrier presents the new line of multi-split systems A complete and flexible range designed to meet every residential and light
More informationHEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
More informationHVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use
More informationComfort Conditioning & Indoor Air Quality
This article was published in ASHRAE Journal, May 2011. Copyright 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Reprinted here by permission from ASHRAE at www.newellinstruments.com.
More informationTECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.
TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA
More informationInstallation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types
Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U:
More informationINDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More informationINDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS
More informationUnder sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
More informationPlease read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
More informationComfosystems Systems with heat recovery for a comfortable indoor climate
Comfosystems Systems with heat recovery for a comfortable indoor climate always around you Heating Cooling Fresh Air Clean Air Zehnder everything you need to create a comfortable, healthy and energy-efficient
More informationInstallation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
More informationDUCTED AIR CONDITIONING SOLUTIONS
DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
More informationMechanical and Natural Ventilation
BBSE3006: Air Conditioning and Refrigeration II http://www.hku.hk/bse/bbse3006/ Mechanical and Natural Ventilation Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong E-mail:
More informationSingle Zone LCD Thermostat Operating Instructions
Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
More information