SPECIFICATIONS WALL MOUNTED, 1 WORKER FILTRATION SYSTEM

Size: px
Start display at page:

Download "SPECIFICATIONS WALL MOUNTED, 1 WORKER FILTRATION SYSTEM"

Transcription

1 , W/O WALL MOUNTED, 1 WORKER FILTRATION SYSTEM Allegro air filtration panels filter impurities and hydrocarbons from an air compressor to convert to breathable air. To meet OSHA requirements an optional CO monitor is available for continuous monitoring of carbon monoxide levels. Panel provides up to 15 CFM (25.48 m 3 /hr) of air within a PSI ( bar) range. CONSTRUCTION; Mounted on a rugged wall bracket External Connections: Optional Remote Strobe Light Alarm Electrochemical, replaceable Normal Operation, Peak, Battery Charge and Calibration mode. First Stage: 5 micron particulate element and automatic mechanical drain Third Stage: ppm activated carbon filter element and manual drain Regulator: High pressure, adjusting pressure knob, ( bar) pressure gauge and an Flow Meter: Adjustable metering valve, range from LPM 21¼ (53.9 cm) 8¼ (20.9 cm) 7¾ (19.6 cm) 11 lbs (4.9 kg)

2 Description: FILTRATION SYSTEM , W/O FIXED TO 2 OUTPUTS System for compressed air filtration that meets NIOSH regulations for breathing systems. Three stages of filtration: to dust, water, oil and hydrocarbons from compressed air. Optional Carbon Monoxide monitor is provided to monitor gas concentrations. Provides filtered air for Grade D breathing. FILTER SYSTEM: 1st stage: 2nd Stage: 3rd Stage: Regulator: Manometer: Filter 5 micron particles and automatic drain Coalescing filter cloth and drain 0010 microns manual Activated carbon filter of microns and manual drain High pressure adjustable knob range PSI gauge and external valve pressure relief Acrylic translucent, Teflon float, with adjustable valve. Graduations: LPM CARBON MONOXIDE MONITOR : Power Source: 115V AC adapter 9V DC 9V DC Alkaline battery (optional) Alarm: 10 ppm (Canada: 5ppm) with external connection for strobe light alarm. (PN optional) Audible Alarm: 90 db (Piezo) External LED Light Censor: Electrochemical, replaceable Buttons: "Mode" and "Set" Liquid Crystal Operations: Average, maximum battery charge and calibration Calibration: Auto Tune to 20 ppm of carbon monoxide 13" (32.5) 6" (15) 12" (30) 18 (8.1) Rev B

3 , W/O WALL MOUNTED, 5 WORKER SYSTEM Allegro air filtration panels filter impurities and hydrocarbons from an air compressor to convert to breathable air. To meet OSHA requirements an optional CO monitor is available for continuous monitoring of carbon monoxide levels. Panel provides up to 60 CFM ( m 3 /hr) of air within a PSI ( bar) range. A 12 gauge, black powder coated steel bracket for mounting Power Source: 115V AC to 9V DC power adapter for continuous power supply 9V DC Alkaline battery (primary or as back up for AC adapter) Alarm Setting: 10 PPM (Canada: 5 PPM) Ext. Connections: Optional strobe light alarm Audible: 90 decibel Piezo alarm External power LED light signal Electrochemical, replaceable Normal operation, peak, battery charge and calibration mode Third Stage: ppm activated carbon filter element and manual drain Regulator: High pressure, adjusting pressure knob, ABS cover, psi ( bar) pressure gauge and an set at 125 psi (8.62 bar) 22 (55.8 cm) 7 (17.7 cm) 7¾ (19.6 cm) 15 lbs (6.8 kg)

4 , W/O WALL MOUNTED, 8 WORKER SYSTEM Allegro air filtration panels filter impurities and hydrocarbons from an air compressor to convert to breathable air. To meet OSHA requirements an optional CO monitor is available for continuous monitoring of carbon monoxide levels. Panel provides up to 100 CFM (169.9 m 3 /hr) of air within a PSI ( bar) range. 12 gauge black powdered coated steel mounting bracket External Connections: Optional Strobe Light Alarm. Electrochemical replaceable Normal Operation, Peak, Battery Charge and Calibration mode. Third Stage: micron activated carbon filter element and manual drain Regulator: High pressure, adjusting pressure knob, psi ( bar) pressure gauge and Flow Meter: Adjustable metering valve, range from LPM 25 (63.5 cm) 7 (17.7 cm) 14 (35.5 cm) 21 lbs (9.5 kg)

5 INLINE FILTER , (W/O) WALL MOUNTED, 150 CFM FLOW-THRU, 1-12 WORKER SYSTEM Allegro air filtration panels filter impurities and hydrocarbons from an air compressor to convert to breathable air. To meet OSHA requirements, a CO monitor is available for continuous monitoring of carbon monoxide levels. Panel provides up to 150 CFM (254.8 m 3 /hr) of air within a PSI ( bar) range. Meets NIOSH requirements for point-ofattachment. 12 gauge black powdered coated steel mounting bracket Inlet side: 1 NPT male nipple, made of Brass Outlet side: ¾ NPT male nipple, made of Brass (Included in model) External Connections: Optional Strobe Light Alarm. Electrochemical replaceable Normal Operation, Peak, Battery Charge and Calibration mode. Third Stage: micron activated carbon filter element and manual drain Regulator: High pressure, adjusting pressure knob, psi ( bar) pressure gauge and Flow Meter: Adjustable metering valve, range from LPM 22 (55.8 cm) 10 (25.4 cm) 19 (48.2 cm) 27 lbs (12.2 kg) Rev A

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake

More information

3Portable Compressed Air Filter and Regulator Panel 256-02-00, with Carbon Monoxide Filtration and Monitor

3Portable Compressed Air Filter and Regulator Panel 256-02-00, with Carbon Monoxide Filtration and Monitor FOR MORE INFORMATION In United States, contact: Internet: www.3m.com/occsafety Technical Assistance: 1-800-243-4630 For other 3M products: 1-800-3M-HELPS or 1-651-737-6501 In Canada, contact: Internet:

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

In-Line Filters and Coalescers with Automatic Drains

In-Line Filters and Coalescers with Automatic Drains Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid

More information

CleanAir Air Control Equipment Accessories for superior spray finishing. Filters Regulators Gauges Valves

CleanAir Air Control Equipment Accessories for superior spray finishing. Filters Regulators Gauges Valves I-4057-H 2-08 CleanAir Air Control Equipment Accessories for superior spray finishing. Filters Regulators Gauges Valves WATERBORNE COMPATIBLE CleanAir for a Quality Finish Selecting the right equipment

More information

Compressed Air Filters

Compressed Air Filters Compressed Air Filters Superior Filtration for Increased Productivity What happens when you don t use an air filter? Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that

More information

CONTINUOUS FLOW BREATHING AIR PURIFIERS

CONTINUOUS FLOW BREATHING AIR PURIFIERS CONTINUOUS FLOW BREATHING AIR PURIFIERS CATALITE CBA SERIES dedicated to excellence... Since 1948, compressed air users around the world have relied on Hankison to provide innovative compressed air treatment

More information

HYDROSTATIC TEST PUMPS

HYDROSTATIC TEST PUMPS HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy

More information

How To Remove A Large Particle From A Large Tank

How To Remove A Large Particle From A Large Tank Delta Series Premium Filters www.numatics.com Table of Contents Delta Series Features and Benefits 3 Science of Coalescing Filtration 4 Water Separator 5 How to Order - Water Separator 6 Pressure and Temperature

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information

Atlas Copco Quality Air Solutions. Compressed Air Filters

Atlas Copco Quality Air Solutions. Compressed Air Filters Atlas Copco Quality Air Solutions Compressed Air Filters Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air for superior operational

More information

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators Condensate Treatment Solutions CTS Series Eliminator II Oil-Water Separators 2 Condensate Treatment Solutions A Cleaner Environment & Reduced Disposal Costs Compressed air is compressed and discharged

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Ultra-Filter. Compressed Air Filter. DF Series

Ultra-Filter. Compressed Air Filter. DF Series Ultra-Filter DF Series ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed air purification equipment, Donaldson has built a comprehensive engineering, manufacturing,

More information

Element D Services Plumbing

Element D Services Plumbing Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

Air Compressor Catalogue

Air Compressor Catalogue www.sparmaxair.com Air Compressor Catalogue e-mail: info@sparmaxair.com Tel: +886.2.2345.1868 Fax: +886.2.2345.3162 Address: 4B-03 Taipei World Trade Center 4F No.5 Sec.5 HsinYi Rd Taipei Taiwan 11011

More information

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: 31 3362-2400 w.tecni-ar.com.br

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: 31 3362-2400 w.tecni-ar.com.br OIL-X EVOLUTION ENGINEERING YOUR SUCCESS. OIL-X EVOLUTION High Efficiency Compressed Air Filtration OIL-X EVOLUTION is a range of high efficiency compressed air filters consisting of coalescing filter

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS ADVANTAGE PLUS SITE REQUIREMENTS SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS 50096-927 Rev A For additional information contact your Medivators Pg 1 of 18 SITE REQUIREMENTS The purpose of this section

More information

Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8" to 1-1/2" port sizes

Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8 to 1-1/2 port sizes Section 12 Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8" to 1-1/2" port sizes B7 Miniature eneral Purpose Filter/Regulator 1/8" and 1/" ports...................................le-12-2

More information

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems 185, 600, 1200, 1800, 2700 Series Portable Purification Systems FEATURING Global Filtration Technology PRINCIPLES OF OPERATION Contaminated oil is drawn into the Parker Portable Purification System by

More information

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED General Air Type P Hydryer Heat Regenerative Systems Introduction General Air Type P Hydryers are electric heat regenerative dryers, designed

More information

ThermoSorb Desiccant Dryers

ThermoSorb Desiccant Dryers ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression

More information

Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers

Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers Filtering Samples to On-Line Process Analyzers Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers Filtering samples to on-line analyzers Use these guidelines to ensure

More information

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS INDOOR AIR QUALITY INSTRUMENTS UNDERSTANDING, ACCELERATED BREATHE A LITTLE EASIER WITH TSI Indoor air quality is a growing concern. With the increasing

More information

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual OHIO MEDICAL CORPORATION Medical Gas Panel Installation and Maintenance Manual P/N 255105 (Rev.5) 08/2005 P/N 255105 (Rev.5) 08/2005 PAGE 2 OHIO MEDICAL CORPORATION PAGE 3 1.0 User Responsibilities The

More information

TECHNICAL DATA. 30a. September 18, 2009 1-1/4-8 (DN32 - DN200)

TECHNICAL DATA. 30a. September 18, 2009 1-1/4-8 (DN32 - DN200) September 18, 2009 30a 1. DESCRIPTION Viking EasyPac Commercial Riser Manifold Assemblies are available in sizes 1-1/4, 1-1/2, 2, 2-1/2, 3, 4, 6 and 8 for commercial systems. They are available with an

More information

ARB AIR LOCKER Air Operated Locking Differentials

ARB AIR LOCKER Air Operated Locking Differentials CKMTA12 & CKMTA24 On-Board Air Compressor Kit, Maximum Performance Specs: ITEM # QTY DESCRIPTION PART # NOTES 01(a) 2 COMPRESSOR ASSEMBLY (12V) CKM01 1 Voltage 12 Volts (CKMTA12), 24 Volts (CKMTA24) 01(b)

More information

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications: E X T E N D I N G Y O U R E N E R G Y DIESEL & JET FUEL FILTRATION EQUIPMENT Applications: Back-Up Diesel Generators Gas Turbines Fueling Terminals for Trucks & Buses Marine Mining Railroad Agriculture

More information

Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations

Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations B e c k m a n C o u l t e r L i f e S c i e n c e s 2 5 0 S. K r a e m e r B o u l e

More information

a range of pollutant free compressors - for pure, clear, oil free air

a range of pollutant free compressors - for pure, clear, oil free air a range of pollutant free compressors - for pure, clear, oil free air 01 The Opus Series Exclusive to Motivair, the Opus Series is a comprehensive and cost-efficient range of quality compressors and related

More information

Self Purging Liquid Trap (SPLT ) User s Manual

Self Purging Liquid Trap (SPLT ) User s Manual Self Purging Liquid Trap (SPLT ) User s Manual High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High

More information

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited

PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited PRODUCT RELEASE CKMTA12 / 24 Copyright 2011 by ARB Corporation Limited ARB 4x4 ACCESSORIES 720 SW 34Th Street Tel: (425) 264-1391 Renton, Washington 98057 Fax: (425) 264-1392 USA North and South American

More information

NITROUS TRANSFER PUMP INSTRUCTIONS

NITROUS TRANSFER PUMP INSTRUCTIONS NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL OPERATING AND MAINTENANCE MANUAL AUTOMATIC SCREEN FILTER FMA SERIE 5000 Sistemas de Filtrado y Tratamiento de Fluidos S.A. Pol. Industrial La Armentera Parc. 86 INDEX INTRODUCTION...3 TECHNICAL CHARACTERISTICS...5

More information

Alarm and Detection/Suppression

Alarm and Detection/Suppression Alarm and Detection/Suppression Fire Safety American Fire Technologies To provide special hazard services world wide to the industrial market through the integration of components and services Clean Agent

More information

Screw Compressors 11-22kW

Screw Compressors 11-22kW INDUSTRIALS GROUP Screw Compressors 11-22kW KSA Plus Fixed Speed, KSV Variable Speed Smart and affordable CHAMPION COMPRESSED AIR TECHNOLOGIES KSA Plus Screw Compressors Up to 45 C ambient temperature

More information

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER Centralizes Monitoring and Alarming for Gas Transmitters and Fire Detectors. The QuadScan II receiver

More information

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description The TYCO RAPID

More information

Regulator Options and Accessories

Regulator Options and Accessories Regulator Options and Accessories Regulator accessories are available separately or mounted on Swagelok regulators. Some accessories limit regulator pressure or temperature ratings. Additional materials,

More information

Innovative to the Core

Innovative to the Core Compressed Air Filter Ultra-Filter Innovative to the Core Significant Increase in Performance due to new Filtration Technology Besides electricity, water and gas, compressed air is one of the most coonly

More information

Impact Uni-Vent 754 Portable Ventilator

Impact Uni-Vent 754 Portable Ventilator Impact Uni-Vent 754 Portable Ventilator Description - Indications- Contraindications- Side Effects- Special Considerations- The Uni-Vent 754 Portable Ventilator is a portable electronically controlled,

More information

Digital Air Pressure Gauge Users Manual

Digital Air Pressure Gauge Users Manual Digital Air Pressure Gauge Users Manual Intercomp Co. 3839 County Road 116 Medina, MN 55340, U.S.A. (763)-476-2531 1-800-328-3336 Fax: 763-476-2613 www.intercompracing.com Manual #: 700099 Rev H Table

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM Designed for centralized medical air production in hospitals and clinics, NOVAIR medical air stations ensure the continuous supply of the medical gas

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Ed.15.01 Design Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Standard 4026/60H Pressure rate PN 40

More information

Hydraulic Flow Control Valves

Hydraulic Flow Control Valves Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

TRL-onlineTOC Monitor is designed for monitoring carbon content in

TRL-onlineTOC Monitor is designed for monitoring carbon content in TRL-onlineTOC Online TOC Monitor TRL-onlineTOC Monitor is designed for monitoring carbon content in Industrial process water To control and monitor different processes where water is used for heating or

More information

Oil Filtration Systems. Filtakleen By-Pass Oil Filter INSTALLATION INSTALLATION & & SERVICE MANUAL MANUAL

Oil Filtration Systems. Filtakleen By-Pass Oil Filter INSTALLATION INSTALLATION & & SERVICE MANUAL MANUAL Filtakleen By-Pass Oil Filter Oil Filtration Systems INSTALLATION INSTALLATION & & SERVICE MANUAL MANUAL xx INTRODUCTION The Filtakleen By-Pass oil Filter is an ultra-fine 1 micron Bypass filtration system

More information

Installing a Probe. Typical Installation

Installing a Probe. Typical Installation for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods by the Control Drawing referenced on the product s name tag 2. The Feed Through Assembly

More information

Parts List: AirHawk II Air Mask

Parts List: AirHawk II Air Mask Parts List: AirHawk II Air Mask MAINTENANCE AND REPAIR For More Information, call 1-800-MSA-2222 or Visit Our Website at www.msasafety.com CRANBERRY TWP., PENNSYLVANIA, U.S.A. 16066 MSA 312 (L) Rev. 5

More information

Online Infrared Flue Gas Analyzer Gasboard 3000

Online Infrared Flue Gas Analyzer Gasboard 3000 Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume

More information

In-Line Electronic Flow Switches

In-Line Electronic Flow Switches In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS Oil Free Scroll Compressors are constantly evolving ANEST IWATA was the first manufacturer to introduce Oil Free Scroll Compressors in 1991 and has kept

More information

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB MONO BLOCK DIRECTIONAL CONTROL VALVE TS112TSLB TS TS212TSTSJB P T TS312TSDTSTKJ TS112TSJB FEATURES: O RG PORTS to eliminate leakage. POWER BEYOND CAPABILITY to fit your multi valve circuits. BUILT ANTI-DROP

More information

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically

More information

In-Line Electronic Flow Switches

In-Line Electronic Flow Switches In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS TS-250 Rev. 0-00-12-07 Refined Fuels PD Meters Size 2 Type 4-MT & 4D-MT 2 PETROLEUM AND LP-GAS TANK TRUCK METERS 2 4-MT with Air Release, Strainer, Printing Register and Preset Valve 2 4D-MT with Vapor

More information

Impact Uni-Vent 750 Portable Ventilator

Impact Uni-Vent 750 Portable Ventilator Impact Uni-Vent 750 Portable Ventilator Description - Indications- Contraindications- Side Effects- Special Considerations- The Uni-Vent 750 Portable Ventilator is a portable electronically controlled,

More information

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction Reverse Osmosis Parts Introduction Reverse Osmosis Flow Chart AQUAPRO INDUSTRIAL CO.,LTD Triple Membrane WATER IMPROVER WATER IMPROVER 2 Reverse Osmosis Electrical Diagram AC-220V Power (2.0 point) (W)

More information

Relief Valves, Regulators, 11Pumps & Boosters

Relief Valves, Regulators, 11Pumps & Boosters Relief Valves, Regulators, 11Pumps & Boosters 114 Kapittel 11: Relief Valves, Regulators, Pumps & Boosters HEROSE RELIEF VALVE BRASS TYPE 06205 SERIES, CE marked H06205-0200.5000 30 BAR 1/4 NPT SP fra

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

Streaming Potential System (SPT1000, SPD1000)

Streaming Potential System (SPT1000, SPD1000) Streaming Potential System (SPT1000, SPD1000) User's Manual Sentrol Systems, Inc. 3949 Cotswold Dr. SW, Lilburn, GA 30047-2371 Tel: 770-564-1541, Fax: 770-564-8605 www.sentrolsystems.com Since the streaming

More information

Validation of process gas systems

Validation of process gas systems Validation of Process Gas Systems By Jeff Hargroves Alza Corporation Validation of process gas systems involve documenting the expected system behavior, and verifying that the system performs as expected.

More information

Residential & Commercial Alarm Systems by Gross Security, LLC

Residential & Commercial Alarm Systems by Gross Security, LLC 151 Main Street, Suite, 1, Get these great features with a landline or cellular alarm system from Gross Security, LLC Alarm system prices include installation Base system includes one hour of training

More information

Nu/Clean 818 XLR-FB Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing

Nu/Clean 818 XLR-FB Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing Nu/Clean 818 XLR-FB Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing Since 1952, Technical Devices has been supplying the electronics industry with the highest quality production

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

Heavy Duty Industrial Air Compressors

Heavy Duty Industrial Air Compressors HEAVY DUTY SERIES - VERTICAL TANK MOUNTED All units mounted on air receivers rated at 200 psi and CRN approved for Canada. All units may be ordered with magnetic starter (Starter supplied loose). All units

More information

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 Form No. 74-00-4001 S168-195-001 Revision E DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 INTRODUCTION Allied Healthcare Products, Inc. s Digital Alarm

More information

Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller

Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller Specifications Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller Introduction These purchase specifications cover the minimum requirements of a Single Deadman Air Lifting Bag (ALB) Controller

More information

VAULT GAS MONITOR SMOKE DETECTOR OPTION

VAULT GAS MONITOR SMOKE DETECTOR OPTION Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 VAULT GAS MONITOR Model 2400-01 Model 2400-21 SMOKE DETECTOR OPTION MODEL 2404-00 APPLICABILITY & EFFECTIVITY

More information

SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS. Value and Performance Through Advanced Technology

SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS. Value and Performance Through Advanced Technology SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS Value and Performance Through Advanced Technology ABOUT PNEUMATIC PRODUCTS PPC s Heritage Since 1946, PPC has been recognized

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

08.08 Vic-Check Valves

08.08 Vic-Check Valves The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc

More information

Model 1210C Battery Powered Pump Shown. Description

Model 1210C Battery Powered Pump Shown. Description 12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

ThermoStar Refrigeration Air Dryers

ThermoStar Refrigeration Air Dryers ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION DATE: July 2011 DESCRIPTION: Compressor Kit, Twin Portable 12V APPLICATION: Maximum performance portable air supply for tyre inflation & air power tools PART NO. : CKMTP12 AVAILABILITY DATE In stock now

More information

Baumann 87000 Flexsleev Sanitary Control Valve

Baumann 87000 Flexsleev Sanitary Control Valve Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found

More information

Dryaire Desiccant System

Dryaire Desiccant System Instructions/Parts Dryaire Desiccant System 310595F Model 6760 Maximum Operating Pressure: 160 PSI (1.1 MPa, 11 bar) System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance

More information

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you! CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different

More information

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air

More information

How To Use A Ds340 (Dsp)

How To Use A Ds340 (Dsp) Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (water meter with pulse output proportional to flow rate)

More information

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer 450 Analyzer 450 Analyzer Fast, Continuous Measurement Compliant with USP, Ch P, EP and JP USB Data Logging and Printer Output Robust Portable Design Portable, Real-time, Continuous Total Organic Carbon

More information

Spill Containers. 517 Series 3 ½ Gallons AST Spill Container. 518 Series 7 ½ Gallon AST Spill Container. 515 Series AST Remote Spill Container

Spill Containers. 517 Series 3 ½ Gallons AST Spill Container. 518 Series 7 ½ Gallon AST Spill Container. 515 Series AST Remote Spill Container Spill Containers 517 Series 3 ½ Gallons AST Spill Container Installed on aboveground storage tanks for the purpose of containing small spills and drips from the fill nozzle. 3 ½ gallon capacity. Steel

More information

AIR OPERATED OIL PUMPS AND KITS

AIR OPERATED OIL PUMPS AND KITS PM 2 AIR OPERATED OIL PUMPS AND KITS PM 2 Oil pump, pressure ratio : 0 Double acting air operated pumps for transferring lubricants and other non-corrosive fluids. Pump includes bung adapter. New Model

More information

CSD WATER REMOVAL FILTERS FOR DIESEL

CSD WATER REMOVAL FILTERS FOR DIESEL CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve

More information

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR INTRODUCTION The Cirro MK 3 is a fully professional mist generator for producing sufficient airborne reflection particles to enable effect lighting to

More information

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact: 7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca

More information

DESIGN STANDARDS SECTION 23 60 00

DESIGN STANDARDS SECTION 23 60 00 PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.

More information