2. Classification based on delivery: Constant delivery pumps. Variable delivery pumps.

Size: px
Start display at page:

Download "2. Classification based on delivery: Constant delivery pumps. Variable delivery pumps."

Transcription

1 Lecture 7 HYDRAULIC PUMPS Learning Objectives Upon completion of this chapter, the student should be able to: Classify the hydraulic pumps used in the industry. Differentiate between positive displacement and non-positive displacement pumps. Explain the working and construction of gear, vane and piston pumps. Evaluate the discharge parameters of gear, vane and piston pumps. Define mechanical, volumetric and overall efficiency of pumps. Evaluate the performance parameters of gear, vane and piston pumps. Differentiate between internal and external gear pumps. Differentiatebetween a bent-axis piston pump and a swash plate. State the advantage of balance vane pumps. Explain cavitation and various means to control it. Explain the importance of noise control in pumps. Write a computer program to evaluate the performance of the system. 1.1Introduction The function of a pump is to convert mechanical energy into hydraulic energy. It is the heart of any hydraulic system because it generates the force necessary to move the load. Mechanical energy is delivered to the pump using a prime mover such as an electric motor.partial vacuum is created at the inlet due to the mechanical rotation of pump shaft. Vacuum permits atmospheric pressure to force the fluid through the inlet line and into the pump. The pump then pushes the fluid mechanically into the fluid power actuated devices such as a motor or a cylinder. Pumps are classified into three different ways and must be considered in any discussion of fluid power equipment. 1. Classification based on displacement: Non-positive displacement pumps (hydrodynamic pumps). Positive displacement pumps (hydrostatic pumps).. Classification based on delivery: Constant delivery pumps. Variable delivery pumps.. Classification based on motion: Rotary pump. Reciprocating pump. 1. Classification of Pumps 1..1Classification Based on Displacement Non-Positive Displacement Pumps Non-positive displacement pumps are primarily velocity-type units that have a great deal of clearance between rotating and stationary parts. Non-displacement pumps are characterized by a high slip that increases as the back pressure increases, so that the outlet may be completely closed without damage to the pump or system. Non-positive pumps do not

2 develop a high pressure but move a large volume of fluid at low pressures. They have essentially no suction lift. Because of large clearance space, these pumps are not self-priming. In other words, the pumping action has too much clearance space to seal against atmospheric pressure. The displacement between the inlet and the outlet is not positive. Therefore, the volume of fluid delivered by a pump depends on the speed at which the pump is operated and the resistance at the discharge side. As the resistance builds up at the discharge side, the fluid slips back into the clearance spaces, or in other words, follows the path of least resistance. When the resistance gets to a certain value, no fluid gets delivered to the system and the volumetric efficiency of the pump drops to zero for a given speed. These pumps are not used in fluid power industry as they are not capable of withstanding high pressure. Their maximum capacity is limited to 17 0 bar.these types of pumpsare primarily used for transporting fluids such as water, petroleum,etc.,from one location to another considerable apart location. Performance curves for positive and non-positive displacement pumps are shown in Fig.1.1. Thetwo most common types of hydrodynamic pumps are the centrifugal and the axial flow propeller pumps. Advantages and disadvantages ofnon-positive displacement pumps The advantages are as follows: 1.Non-displacement pumps have fewer moving parts..initial and maintenance cost is low.. They give smooth continuous flow.. They are suitable for handling almost all types of fluids including slurries and sledges. 5.Their operation is simple and reliable. The disadvantages are as follows: 1.Non-displacement pumps are not self-priming and hence they must be positioned below the fluid level.. Discharge is a function of output resistance..low volumetric efficiency Positive Displacement Pumps Positive displacement pumps, in contrast, have very little slips, are self-priming and pump against very high pressures, but their volumetric capacity is low. Positive displacement pumps have a very close clearance between rotating and stationary parts and hence are selfpriming. Positive displacement pumps eject a fixed amount of fluid into the hydraulic system per revolution of the pump shaft. Such pumps are capable of overcoming the pressure resulting from mechanical loads on the system as well as the resistance of flow due to friction. This equipment must always be protected by relief valves to prevent damage to the pump or system. By far, a majority of fluid power pumps fall in this category, including gear, vane and piston pumps.performance curves for positive and non-positive displacement pumps are shown in Fig. 1.1.

3 Positive displacement pumps are classified based on the following characteristics: 1. Type of motion of pumping element: Based on the type of motion of pumping element, positive displacement pumps are classified as follows: Rotary pumps, for example, gear pumps and vane pumps. Reciprocating pumps, for example, piston pumps.. Displacement characteristics: Based on displacement characteristics, positive displacement pumps are classified as follows: Fixed displacement pumps. Variable displacement pumps.. Type of pumping element. The advantages of positive displacement pumps over non-positive displacement pumps are as follows: 1. They can operate at very high pressuresof up to 800 bar (used for lifting oils from very deep oil wells).. They can achieve a high volumetric efficiency of up to 98%.. They are highly efficient and almost constant throughout the designed pressure range.. They are a compact unit, havinga high power-to-weight ratio. 5. They can obtain a smooth and precisely controlled motion. 6. By proper application and control, they produce only the amount of flow required to move the load at the desired velocity. 7. They have a great flexibility of performance. They can be made to operate over a wide range of pressures and speeds. 1.. Classification Based on Delivery Constant Delivery Pumps Constant volume pumps always deliver the same quantity of fluid in a given time at the operating speed and temperature. These pumps are generally used with relatively simple machines, such as saws or drill presses or where a group of machines is operated with no specific relationship among their relative speeds. Power for reciprocating actuators is most often provided by constant volume pumps. 1...Variable Delivery Pumps The output of variable volume pumps may be varied either manually or automatically with no change in the input speed to the pump. Variable volume pumps are frequently used for rewinds, constant tension devices or where a group of separate drives has an integrated speed relationship such as a conveyor system or continuous processing equipment. 1..Classification Based on Motion This classification concerns the motion that may be either rotary or reciprocating. It was of greater importance when reciprocating pumps consisted only of a single or a few relatively large cylinders and the discharge had a large undesirable pulsation. Present-day reciprocating pumps differ very little from rotary pumps in either external appearance or the flow characteristics.

4 Differences between positive displacement pumps and non-positive displacement pumps are enumerated in Table 1.1. Table 1.1 Differences between positive displacement pumps and non-positive displacement pumps Positive Displacement Non-positive Displacement Pumps Pumps The flow rate does not change with head The flow rate is not much affected by the viscosity of fluid Efficiency is almost constant with head The flow rate decreases with head The flow rate decreases with the viscosity Efficiency increases with head at first and then decreases (a) (b) Figure 1.1 Performance curves for positive and non-positive displacement pumps

5 1.Pumping Theory A positive displacement hydraulic pump is a device used for converting mechanical energy into hydraulic energy.it is driven by a prime mover such as an electric motor.it basically performs twofunctions.first, it creates a partial vacuum at thepump inlet port.this vacuum enables atmospheric pressure to force the fluid from the reservoir into the pump.second,the mechanical action of the pump traps this fluid within the pumping cavities,transports it through the pump and forces it into the hydraulic system. It is important to note that pumps create flow not pressure. Pressure is created by the resistance to flow. Rod moves outward Low pressure Outlet Outlet valve is High pressure closed Rod moves inward Outlet Outlet valve is open Breather Inlet valve is closed Strainer Suction stroke Delivery stroke Figure 1.Illustration of pumping theory All pumps operate by creating a partial vacuum at the intake, and a mechanical force at the outlet that induces flow. This action can be best described by reference to a simple piston pump shown in Fig As the piston moves to the left, a partial vacuum is created in the pump chamber thatholds the outlet valve in place against its seat and induces flow from the reservoir that is at a higher (atmospheric) pressure.as this flow is produced, the inlet valve is temporarily displaced by the force of fluid, permitting the flow into the pump chamber (suction stroke).. When the piston moves to the right, the resistance at the valves causes an immediate increase in the pressure that forces the inlet valve against its seat and opens the outlet valve thereby permitting the fluid to flow into the system. If the outlet port opens directly to the atmosphere, the only pressure developed is the one required to open the outlet valve(delivery stroke).

6 1.Gear Pumps Gear pumps are less expensive but limited to pressures below 10 bar.it is noisy in operation than either vane or piston pumps. Gear pumps are invariably of fixed displacement type, which means that the amount of fluid displaced for each revolution of the drive shaft is theoretically constant External Gear Pumps External gear pumps are the most popular hydraulic pumps in low-pressure ranges due to their long operating life, high efficiency and low cost. They are generally used ina simple machinethe most common form of external gear pump is shown in Figs. 1.and 1. It consist of a pump housing in which a pair of preciselymachined meshing gears runs with minimal radial and axial clearance.one of the gears, called a driver,is driven by a prime mover. The driver drives another gear called a follower.as the teeth of the two gears separate, the fluid from the pump inlet gets trapped between the rotating gear cavities and pump housing.the trapped fluid is then carried around the periphery of the pump casing and delivered to outlet port. The teeth of precisely meshed gears provide almost a perfect seal between the pumpinlet and the pump outlet.when the outlet flow is resisted, pressure in the pump outlet chamber builds up rapidly and forces the gear diagonally outward against the pump inlet. When the system pressure increases, imbalance occurs. This imbalance increases mechanical friction and the bearing load of the two gears.hence, the gear pumps are operated to the maximum pressure rating stated by the manufacturer. It is important to note that the inlet is at the point of separation and the outlet at the point of mesh. These units are not reversible if the internal bleeds for the bearings are to be drilled to both the inlet and outlet sides.so that the manufacturer s literature should be checked before attempting a reversed installation. If they are not drilled in this manner, the bearing may be permanently damaged as a result of inadequate lubrications. Advantages and disadvantages of gear pumps The advantages are as follows: 1.They are self-priming..they give constant delivery for a given speed.. They are compact and light in weight.. Volumetric efficiency is high. The disadvantages are as follows: 1. The liquid to be pumped must be clean, otherwise it will damage pump.. Variable speed drives are required to change the delivery.. If they run dry, parts can be damaged because the fluid to be pumped is used as lubricant.

7 Expression for the theoretical flow rate of an external gear pump Let D o =the outside diameter of gear teeth D i = the inside diameter of gear teeth L =the width of gear teeth N=the speed of pump in RPM V D =the displacement of pump in m/rev M= module of gear z=number of gear teeth = pressure angle Volume displacement is VD ( Do Di ) L Di Do (Addendum Dendendum) Theoretical discharge is Q ( m /min) V ( m /rev) N (rev/min) T D If the gear is specified by its module and number of teeth, then the theoretical discharge can be found by Q T cos 0 Lm N z 1 m /min 1 Figure 1.Operation of an external gear pump

8 1..Internal Gear Pumps Another form of gear pump is the internal gear pump, which is illustrated in Fig They consist of two gears:an external gear and an internal gear. The crescent placed in between these acts as a seal between the suction and discharge.(fig.1.6) When a pump operates, the external gear drives the internal gear and both gears rotate in the same direction. The fluid fills the cavities formed by the rotating teeth and the stationary crescent. Both the gears transport the fluid through the pump. The crescent seals the low-pressure pump inlet from the high-pressure pump outlet. The fluid volume is directly proportional to the degree of separation and these units may be reversed without difficulty. The major use for this type of pump occurs when a through shaft is necessary, as in an automatic transmission. These pumps have a higher pressure capability than external gear pumps. 1.. Gerotor Pumps Figure 1.5Operation of an internal gear pump Gerotor pumps operate in the same manner as internal gear pumps. The inner gear rotor is called a gerotor element. The gerotor element is driven by a prime mover and during the operation drives outer gear rotor around as they mesh together. The gerotor has one tooth less than the outer internal idler gear. Each tooth of the gerotor is always in sliding contact with the surface of the outer element. The teeth of the two elements engage at just one place to seal the pumping chambers from each other. On the right-hand side of the pump, shown in Fig. 1.7, pockets of increasing size are formed, while on the opposite side, pockets decrease in size. The pockets of increasing size are suction pockets and those of decreasing size are discharge pockets. Therefore, the intake side of the pump is on the right and discharge side on the left. Pumping chambers are formed by the adjacent pair of teeth, which are constantly in contact with the outer element, except for clearance. Refer to Fig 1.7,asthe rotor is turned, its gear tips are accurately machined sothat they precisely follow the inner surface of the outer element. The expanding chambers are created as the gear teeth withdraw. The chamber

9 reaches its maximum size when the female tooth of the outer rotor reaches the top dead center. During the second half of the revolution, the spaces collapse, displacing the fluid to the outlet port formed at the side plate. The geometric volume of the gerotor pump is given as VD b Z ( Amax Amin ) where b is the tooth height, Z is the number of rotor teeth, A max is the maximum area between male and female gears (unmeshed occurs at inlet) and A min is the minimum area between male and female gears (meshed occurs at outlet). Figure 1.7Gerotor gear pump Example 1.1 The inlet to a hydraulic pump is 0.6 m below the top surface of an oil reservoir. If the specific gravity of the oil used is 0.86, determine the static pressure at the pump inlet. Solution: We know that Pressure gh The density of water is 1 g/cm or 1000 kg/m. Therefore, the density of oil is g/cm or 860 kg/m. Pressure at the pump inlet is P= kg/m = 516 kg/m = kg/cm bar bar (Note: 1 kg/cm bar.) Example 1. A hydraulic pump delivers 1 L of fluid per minute against a pressure of 00 bar. (a) Calculate the hydraulic power. (b) If the overall pump efficiency is 60%, what size of electric motor would be needed to drive the pump? Solution: (a) Hydraulic power is given by (b) We have 00 (bar) Hydraulic power (kw) 1 L/min kw 600 Hydraulic power Electric motor power (power input) = Overall efficiency

10 Substituting we get Electric motor power (power input) = 6.67kW 0.6 Electric motor power 6.67 kw 0.6 Example 1. A gear pump has an outside diameter of 80mm, inside diameter of 55mm and a width of 5mm. If the actual pump flow is 1600 RPM and the rated pressure is 95 LPM what is the volumetric displacement and theoretical discharge. Solution: We have Outside diameter Do 80 mm Inside diameter Di 55 mm Width d 5mm Speed of pump N = 1600 RPM Actual flow rate = 95 LPM Now Q A 95 LPM m /min VD ( Do Di ) L 5 V D ( ) m / rev Theoretical flow rate QT ( Do Di ) L N = ( ) = m /min Example 1. Calculate the theoretical delivery of a gear pump. Module of the gear teeth is 6mm and width of gear teeth is 5mm. Number of teeth on driver gear is 18 and pressure angle of the gear is 0. Pump speed is 1000 RPM. Volumetric efficiency is 90%. Solution: If the gear is specified by its module and number of teeth, then the theoretical discharge can be found by

11 Q T cos Lm N z 1 m /min 1 cos 0 (0.05)(6 10 ) m /min m /min Example 1.5 Calculate the theoretical delivery of a gear pump. Module of the gear teeth is 6mm and width of gear teeth is 65mm. Number of teeth on driver gear is 16 and pressure angle of the gear is 0. Pump speed is 1600 RPM. Outer diameter of gear is 108 mm and Dedendum circle diameter is 81 mm. Volumetric efficiency is 88%at 7 MPa. Solution: If the gear is specified by its module and number of teeth, then the theoretical discharge can be found by Q T cos 0 Lm N z 1 m /min (0.065)(6 10 ) m /min m /min Alternatively we can use VD ( Do Di ) L Q T ( ) m /rev 1.5Lobe Pumps The operation of lobe pump shown in Fig.1.9 is similar to that of external gear pump, but they generally have a higher volumetric capacity per revolution. The output may be slightly greater pulsation because of the smaller number of meshing elements. Lobe pumps, unlike external gear pumps,have both elements externally driven and neither element hasany contact with the other.for this reason, they are quieter when compared to other types of gear pumps. Lobe contact is prevented by external timing gears located in the gearbox.pump shaft support bearings are located in the gearbox, and because the bearings are out of the pumped liquid, pressure is limited by bearing location and shaft deflection. They do not lose efficiency with use. They are similar to external gear pumps with respect to the feature of reversibility.

12 Stages of operation of Lobe pump 1.As the lobes come out of mesh, they create expanding volume on the inlet side of the pump.liquid flows into the cavity and is trapped by the lobes as they rotate..liquid travels around the interior of the casing in pockets between the lobes and the casing (it does not pass between the lobes)..finally, the meshing of the lobes forces the liquid through the outlet port under pressure. Lobe pumps are frequently used in food applications because they are good at handling solids without inflicting damage to the product. Solid particle size can be much larger in lobe pumps than in other positive displacement types.because lobes do not make contact, and clearances are not as close as in other positive displacement pumps, this design handles lowviscosity liquids with diminished performance.loading characteristics are not as good as other designs and suction ability is low.high-viscosity liquids require reduced speeds to achieve satisfactory performance.reductions of 5% of rated speed and lower are common with high-viscosity liquids.

13 1.5.1Advantages The advantages of lobe pumps are as follows: 1. Lobe pumps can handle solids, slurries, pastes and many liquid.. No metal-to-metal contact.. Superior CIP(Cleaning in Place) /SIP(Sterilization in Place) capabilities.. Long-term dry run (with lubrication to seals). 5. Non-pulsating discharge. 1.5.Disadvantages The disadvantages of lobe pumps are as follows: 1. Require timing gears.. Require two seals.. Reduced lift with thin liquids. 1.5.Applications Common rotary lobe pump applications include, but are not limited to, the following: 1. Polymers.. Paper coatings.. Soaps and surfactants.. Paints and dyes. 5. Rubber and adhesives. 6. Pharmaceuticals. 7. Food applications. 1.6Screw Pumps These pumps have two or more gear-driven helical meshing screws in a closefitting caseto develop the desired pressure. These screws mesh to form a fluid-type seal between the screws and casing. A schematic diagram of a screw pump is shown in Fig A two-screw pump consists of two parallel rotors with inter-meshing threads rotating in a closely machined casing. The driving screw and driven screw are connected by means of timing gears. When the screws turn, the space between the threads is divided into compartments. As the screws rotate, the inlet side of the pump is flooded with hydraulic fluid because of partial vacuum.when the screws turn in normal rotation, the fluid contained in these compartments is pushed uniformly along the axis toward the center of the pump, where the compartments discharge the fluid. Here the fluid does not rotate but moves linearly as a nut on threads. Thus, there are no pulsations at a higher speed; it is a very quiet operating

14 pump.. To the discharge. and carried along in these spaces 1. As this screw rotates. This screw also rotates and oil is drawn here Ina screw pump, a chamber is formed between thread and housing as shown in Fig The following expression gives the volumetric displacement π α sin α D d Heres is the stroke length and cos( α) D VD ( D d ) s D s Figure 1.11Volumetric displacement of a screw pump Advantages and disadvantages of screw pump Theadvantages are as follows: 1.They are self-priming and more reliable.. They are quiet due to rolling action of screw spindles..they can handle liquids containing gases and vapor.. They have long service life. The disadvantages are as follows:

15 1.They are bulky and heavy..they are sensitive to viscosity changes of the fluid.. They have low volumetric and mechanical efficiencies.. Manufacturing cost of precision screw is high.

Design and Modeling of Fluid Power Systems ME 597/ABE 591 Lecture 5

Design and Modeling of Fluid Power Systems ME 597/ABE 591 Lecture 5 Systems ME 597/ABE 591 Lecture 5 Dr. Monika Ivantysynova MAHA Professor Fluid Power Systems MAHA Fluid Power Research Center Purdue University Displacement Machines Study different design principles and

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 1 HYDRAULIC PUMPS The material needed for outcome 2 is very extensive so there

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 3 HYDRAULIC AND PNEUMATIC MOTORS The material needed for outcome 2 is very extensive

More information

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps Pump ED 101 Positive Displacement Pumps Part I Reciprocating Pumps Joe Evans, Ph.D http://www.pumped101.com There are many pump designs that fall into the positive displacement category but, for the most

More information

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc. CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc. 1 Centrifugal Pump- Definition Centrifugal Pump can be defined as a mechanical device used to transfer liquid of various types. As

More information

Radial piston pumps type R and RG

Radial piston pumps type R and RG Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power

More information

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE) Guidelines for Processing Plant Page : 1 of 51 Rev 01 Feb 2007 Rev 02 Feb 2009 Rev 03 KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru. (ENGINEERING DESIGN GUIDELINE)

More information

Module 5: Hydraulic Systems Lecture 1 Introduction

Module 5: Hydraulic Systems Lecture 1 Introduction 1. Introduction Module 5: Hydraulic Systems Lecture 1 Introduction The controlled movement of parts or a controlled application of force is a common requirement in the industries. These operations are

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive

More information

PART 2 FORKLIFT HYDRAULIC SYSTEM

PART 2 FORKLIFT HYDRAULIC SYSTEM PART 2 FORKLIFT HYDRAULIC SYSTEM Chapter 1 Description and Operation Component Locations & Circuit Layouts 1 Hydraulic Pump 11 Control Valve 14 Valve Section Oil Flows 15 Anti-Cavitation Valve 22 Velocity

More information

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy). HYDRAULIC MACHINES Used to convert between hydraulic and mechanical energies. Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic

More information

COUNTERBALANCE VALVES

COUNTERBALANCE VALVES COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 5 Pumps 1 Guidelines for the Design, Construction and Testing of Pumps Edition 2007 The following Guidelines come into force

More information

GoTo Europe Focused Delivery Program. Product overview industrial and mobile hydraulics

GoTo Europe Focused Delivery Program. Product overview industrial and mobile hydraulics GoTo Europe Focused Delivery Program Product overview industrial and mobile hydraulics 2 GoTo Europe The products I need when I need them In today s global competition every day counts. Fast response times

More information

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

GoTo Europe Focused Delivery Program. Product Overview Hydraulics GoTo Europe Focused Delivery Program Product Overview Hydraulics 2 GoTo Europe The products I need when I need them In today s global competition every day counts. Fast response times have become an important

More information

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS 426 2.98 23.01

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS 426 2.98 23.01 SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS RPT SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +4 581 661 111, fax: +4 581 602 587 Email: sigmahra@sigmahra.cz 426

More information

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109 INDEX Description Page Delta Power Rotary Flow Divider, Positive Displacement (Application Data) 36 P Series, Equal Flow Two Sections 39 P Series, Equal Flow Multi-Sections 40 PM Series, Equal Flow Multi-Sections

More information

Fig 1 Power Transmission system of Tractor

Fig 1 Power Transmission system of Tractor POWER TRANSMISSION SYSTEM Transmission is a speed reducing mechanism, equipped with several gears (Fig. 1). It may be called a sequence of gears and shafts, through which the engine power is transmitted

More information

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES 4.0 PUMP CLASSES Pumps may be classified in two general types, dynamic and positive displacement. Positive displacement pumps

More information

Section IV VACUUM PUMPS. Vacuum Pumps: Basic Operation

Section IV VACUUM PUMPS. Vacuum Pumps: Basic Operation VACUUM PUMPS Section IV Equipment used to generate vacuum, as noted earlier, is similar to air compressors. It's even possible to generate compressed air or vacuum with the same machine, depending on how

More information

EXPERIMENT NO. 3. Aim: To study the construction and working of 4- stroke petrol / diesel engine.

EXPERIMENT NO. 3. Aim: To study the construction and working of 4- stroke petrol / diesel engine. EXPERIMENT NO. 3 Aim: To study the construction and working of 4- stroke petrol / diesel engine. Theory: A machine or device which derives heat from the combustion of fuel and converts part of this energy

More information

Vertical selfpriming Side-Channel Pumps Type WPV

Vertical selfpriming Side-Channel Pumps Type WPV Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001 Pressure Control Chapter 3 Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001 Introduction Pressure control is a key element in the design of any circuit. Used correctly, it can

More information

AXIAL PISTON-PRESSURE EXCHANGER DEVELOPMENT PROGRAM. 1.0 Abstract

AXIAL PISTON-PRESSURE EXCHANGER DEVELOPMENT PROGRAM. 1.0 Abstract AXIAL PISTON-PRESSURE EXCHANGER DEVELOPMENT PROGRAM John P. MacHarg, Ocean Pacific Technologies, Ventura, CA, USA 1.0 Abstract Through a contract with the United States Office of Naval Research (ONR),

More information

Mechanical shaft seal types and sealing systems

Mechanical shaft seal types and sealing systems Chapter 2 Mechanical shaft seal types and sealing systems 1. Mechanical shaft seal types 2. Sealing systems 3. Selecting a mechanical shaft seal Mechanical shaft seal types and sealing systems 1. Mechanical

More information

HCS Teknik Bobinaj Soğutma Kompresörleri Bakım, Onarım, Revizyon - How Cooling System Operates?

HCS Teknik Bobinaj Soğutma Kompresörleri Bakım, Onarım, Revizyon - How Cooling System Operates? The operational cycle of a standard cooling system is shown on the diagram below. There are 3 main elements in a cooling system. The compressor, evaporator and condenser. There are other equipment also

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

Imo Pump. www.imo-pump.com. Imo Rotary & Centrifugal Pumps Quick Selection Guide. www.imo-pump.com. The reliable pump people

Imo Pump. www.imo-pump.com. Imo Rotary & Centrifugal Pumps Quick Selection Guide. www.imo-pump.com. The reliable pump people Imo Pump Imo Rotary & Centrifugal Pumps Quick Selection Guide ALLHEAT series pump in heat transfer fluid service Germany 3G series pump in compressor lube service Buffalo, NY, USA CIG series pumps in hydraulic

More information

The Secret of Hydraulic Schematics. BTPHydraulics www.iranfluidpower.com

The Secret of Hydraulic Schematics. BTPHydraulics www.iranfluidpower.com The Secret of Hydraulic Schematics BTPHydraulics www.iranfluidpower.com www.iranfluidpower.com Table of Contents The Secret to Reading and Interpreting Hydraulic Schematics... 1 Hydraulic System Schematics...

More information

INTERNATIONAL FIRE TRAINING CENTRE FIREFIGHTER INITIAL PUMPS AND PRIMERS. Throughout this note he means he/she and his means his/hers.

INTERNATIONAL FIRE TRAINING CENTRE FIREFIGHTER INITIAL PUMPS AND PRIMERS. Throughout this note he means he/she and his means his/hers. INTERNATIONAL FIRE TRAINING CENTRE FIREFIGHTER INITIAL PUMPS AND PRIMERS Throughout this note he means he/she and his means his/hers. Areas of bold type are considered to be of prime importance. INTRODUCTION

More information

Rexroth Hydraulic Pump A10VO Series User Manual

Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference

More information

Introduction. The following is an outline of the contents of this paper: Definition of Artificial Lift Page 2. How an Oil Well is Produced Page 2

Introduction. The following is an outline of the contents of this paper: Definition of Artificial Lift Page 2. How an Oil Well is Produced Page 2 Introduction Canadian Oilwell Systems Company and it s subsidiaries are suppliers of oil well Electric Submersible Pumping systems (ESPs). Such pumps are used to lift oil from oil wells so that the oil

More information

MACHINE TOOL DRIVES. Learning Objectives:

MACHINE TOOL DRIVES. Learning Objectives: MACHINE TOOL DRIVES Learning Objectives: Broadly Classification of transmission of rotary motion Stepped Speed Drives in Machine Tools Belting Pick-Off Gears Gear boxes AP &GP for steeping speeds of gears

More information

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711 A10VO Nominal size 18 see RD 92712 A10VO Nominal size 28...140 see RD 92711 The variable displacement axial piston pump A10VO in swashplate design was designed for hydrostatic drives in open circuits.

More information

Uniquely designed and engineered specifically for the pulp and paper industry.

Uniquely designed and engineered specifically for the pulp and paper industry. Universal SPU2 Series Uniquely designed and engineered specifically for the pulp and paper industry. For more than half a century, Waukesha Cherry-Burrell has been a leader in the design, manufacturing

More information

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps An SPX Process Equipment Operation Universal II Industrial Series Rotary Positive Displacement ECP Pumps New levels of performance. Reduced operational and maintenance costs. For more than half a century,

More information

STEERING SYSTEM - POWER

STEERING SYSTEM - POWER STEERING SYSTEM - POWER 1990 Nissan 240SX 1990 STEERING Nissan - Power Rack & Pinion Axxess, Maxima, Pulsar NX, Sentra, Stanza, 240SX, 300ZX DESCRIPTION The power steering system consists of a rack and

More information

Automatic Transmission Basics

Automatic Transmission Basics Automatic Transmission Basics Lesson Objectives 1. Describe the function of the torque converter. 2. Identify the three major components of the torque converter that contribute to the multiplication of

More information

UNIT II Robots Drive Systems and End Effectors Part-A Questions

UNIT II Robots Drive Systems and End Effectors Part-A Questions UNIT II Robots Drive Systems and End Effectors Part-A Questions 1. Define End effector. End effector is a device that is attached to the end of the wrist arm to perform specific task. 2. Give some examples

More information

ACADEMIC TEXTBOOK FLUID POWER CONTROL SYSTEMS. The lecture: 15 hours. Kielce University of Technology Faculty of Mechatronics and Machine Design

ACADEMIC TEXTBOOK FLUID POWER CONTROL SYSTEMS. The lecture: 15 hours. Kielce University of Technology Faculty of Mechatronics and Machine Design ACADEMIC TEXTBOOK FLUID POWER CONTROL SYSTEMS The lecture: 15 hours Kielce University of Technology Faculty of Mechatronics and Machine Design Author: Ryszard Dindorf Kielce, 2011/2012 1. Fluid power basic

More information

BOWIE PUMPS OPERATION - MAINTENANCE

BOWIE PUMPS OPERATION - MAINTENANCE BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped

More information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system

More information

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module. APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS This work covers part of outcome 2 of the standard Edexcel module. The material needed for outcome 2 is very extensive so

More information

Chapter 3.5: Fans and Blowers

Chapter 3.5: Fans and Blowers Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist

More information

Hydraulic Troubleshooting PRESENTED BY

Hydraulic Troubleshooting PRESENTED BY Hydraulic Troubleshooting PRESENTED BY NORMAN KRONOWITZ Introduction Welcome to the CMA/Flodyne/Hydradyne s Hydraulic Troubleshooting presentation. We will introduce many aspects of troubleshooting hydraulic

More information

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs. TXV - Presentation pumps with Load Sensing control variable displacement piston pumps ADVANTAGES pumps are variable displacement with pressure-flow control called Load Sensing. They self-regulate to give

More information

PUMP AND MOTOR DIVISION

PUMP AND MOTOR DIVISION INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP 1 Check model code / compare with your paper work Nameplate of the pump Ordering / Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation

More information

Mechanical Principles

Mechanical Principles Unit 4: Mechanical Principles Unit code: F/60/450 QCF level: 5 Credit value: 5 OUTCOME 3 POWER TRANSMISSION TUTORIAL BELT DRIVES 3 Power Transmission Belt drives: flat and v-section belts; limiting coefficient

More information

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents English translation of German original Technical Information TI-P11 SITEMA PowerStroke Mould Closing Devices series FS drive system for powerful forces on a short stroke hydraulic actuation closing force

More information

Machine Design II Prof. K.Gopinath & Prof. M.M.Mayuram. Module 2 - GEARS. Lecture 17 DESIGN OF GEARBOX

Machine Design II Prof. K.Gopinath & Prof. M.M.Mayuram. Module 2 - GEARS. Lecture 17 DESIGN OF GEARBOX Module 2 - GEARS Lecture 17 DESIGN OF GEARBOX Contents 17.1 Commercial gearboxes 17.2 Gearbox design. 17.1 COMMERCIAL GEARBOXES Various commercial gearbox designs are depicted in Fig. 17.1 to 17.10. These

More information

Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min Steering unit RE 11872/05.06 /10 Type LAGL Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min H7375 Table of contents Contents Page Features 1 Ordering code 2 Function, section 3 Device

More information

4" SUBMERSIBLE PUMPS

4 SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant

More information

Introduction of Duplex Pump HPD71+71 and Short-Stroke Pump HPV112+112

Introduction of Duplex Pump HPD71+71 and Short-Stroke Pump HPV112+112 Shin-ichi Kamimura Komatsu has come up with a high-pressure, large-capacity, duplex swash plate pump, HPD71+71, as the main pump for PC160-7 and a short-length, tandem swash plate pump (short-stroke pump),

More information

These pumps provide a well proven solution in many cases.

These pumps provide a well proven solution in many cases. Page 1/8 electric fuel pumps Product overview for universal applications PrODuCT INFORMATION Vehicle/application Product PIerburg No. see catalogue/tecdoc CD Electric fuel pump (E1F) 7.21440.51.0/.53.0/.63.0/.68.0/.78.0

More information

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde Hydraulic Motor/Pump Series F11/F12 Fixed Displacement parker.com/pmde Series F11/F12 Torque (M) M = D x p x η hm 63 [Nm] Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5

More information

GEAROLOGY 4-1 WORMS AND WORM GEARS WORMS AND WORM GEARS

GEAROLOGY 4-1 WORMS AND WORM GEARS WORMS AND WORM GEARS GEAROLOGY 4-1 4 4-2 GEAROLOGY COMMON APPLICATIONS: Worm and worm gear sets are used in many, everyday products including: electrical mixers, hubometers, right Now that you have an understanding of two

More information

Gear Trains. Introduction:

Gear Trains. Introduction: Gear Trains Introduction: Sometimes, two or more gears are made to mesh with each other to transmit power from one shaft to another. Such a combination is called gear train or train of toothed wheels.

More information

GEAROLOGY 2-1 SPUR GEARS SPUR GEARS

GEAROLOGY 2-1 SPUR GEARS SPUR GEARS GEAROLOGY 2-1 2 2-2 GEAROLOGY COMMON APPLICATIONS: Spur gears are used to Now that you ve been introduced to both Boston Gear and some of the basics of our Gearology course which we like to call Power

More information

Internal gear pump PGF Series 2X and 3X

Internal gear pump PGF Series 2X and 3X Internal gear pump GF eries 2X and 3X RE 23 Edition: 4.24 Replaces: 5.2 Fixed displacement Frame sizes, 2 and 3 izes.7 to 4 Maximum pressure 25 bar Displacement.7 to 4 cm 3 H758 Features ow operating noise

More information

UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS

UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS Automobile Electrical Structure 3.1 Introduction Objectives 3.2 Ignition System 3.3 Requirement of an Ignition System 3.4 Types of Ignition 3.4.1 Battery or Coil Ignition

More information

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS J J Brasz, Carrier Corporation, Syracuse, NY, 13221, USA joost.j.brasz@carrier.utc.com I K Smith and N Stosic

More information

Hydraulic Trouble Shooting

Hydraulic Trouble Shooting Hydraulic Trouble Shooting Hydraulic systems can be very simple, such as a hand pump pumping up a small hydraulic jack, or very complex, with several pumps, complex valving, accumulators, and many cylinders

More information

Why Lead Screws are the Best Fit for Many Linear Motion Applications - and How to Rightly Apply Them

Why Lead Screws are the Best Fit for Many Linear Motion Applications - and How to Rightly Apply Them Why Lead Screws are the Best Fit for Many Linear Motion Applications - and How to Rightly Apply Them Robert Lipsett, Engineering Manager, Thomson BSA Thomson Industries, Inc. San Jose, CA 800.882.8857

More information

Hydraulically actuated clutches and spring-applied brakes clutch/brake combined units

Hydraulically actuated clutches and spring-applied brakes clutch/brake combined units 왎 Hydraulically actuated clutches and spring-applied brakes clutch/brake combined units Or tlinghaus Plates. Clutches. Brakes. Systems. Hydraulically actuated clutches and spring-applied brakes clutch/brake

More information

Highly flexible couplings

Highly flexible couplings Construction and operation 8.03.00 Instructions for installation 8.03.00 Types of stress 8.04.00 Diagrams for static deformation of the coupling ring 8.05.00 Coupling size 8.07.00 Examples of combinations

More information

High Torque Vane Motors MV015, MV037, MV057, MV125

High Torque Vane Motors MV015, MV037, MV057, MV125 High Torque Vane Motors MV015, MV037, MV057, MV125 2 Unique vane crossing vane design provides maximum versatility This motor is created around the patented vane crossing vane design, a leading-edge concept

More information

Tiguan Haldex All-Wheel Drive

Tiguan Haldex All-Wheel Drive Service Training Self Study Program 861803 Tiguan Haldex All-Wheel Drive Volkswagen of America, Inc. Volkswagen Academy Printed in U.S.A. Printed 3/2008 Course Number 861803 2008 Volkswagen of America,

More information

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement Mobile Hydraulic Pumps T6*M Denison Vane Technology, fixed displacement Contents GENERAL Series T6 Mobile, Denison Vane Pumps Features...3 Instructions...3 Minimum & maximum speeds...4 Pressure ratings...4

More information

Product catalogue, pipe and sewer cleaning systems

Product catalogue, pipe and sewer cleaning systems Product catalogue, pipe and sewer cleaning systems Nozzles Rotorjet trolley Hose reels Cleaning devices www.hammelmann.com Contents (Navigation via Bookmarks) Rotorjet trolley Rotary joints, spray pipes

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

Twin Screw Technology. General Overview and Multiphase Boosting 11/2013. Calgary Pump Symposium 2013

Twin Screw Technology. General Overview and Multiphase Boosting 11/2013. Calgary Pump Symposium 2013 Twin Screw Technology General Overview and Multiphase Boosting 11/2013 Axel Jäschke Technical Director - ITT Bornemann USA Office: Mobile: +1 832 320 2500 +49 170 576 4115 +1 832 293 7935 1 Bio Axel Jäschke

More information

P = n M 9550 [kw] Variable Intake Manifold in VR Engines. Self-study programme 212. Principles and Description of Operation. Service.

P = n M 9550 [kw] Variable Intake Manifold in VR Engines. Self-study programme 212. Principles and Description of Operation. Service. Service. Self-study programme 212 Variable Intake Manifold in VR Engines Principles and Description of Operation P = n M 9550 [kw] M [Nm] P [kw] n [min -1 ] 212_020 The output and torque of an engine have

More information

Pneumatic control for robotics and industrial automation Author: Naresh Raghavan

Pneumatic control for robotics and industrial automation Author: Naresh Raghavan Pneumatic control for robotics and industrial automation Author: Naresh Raghavan Introduction Pneumatic systems form the most primitive and distinct class of mechanical control engineering. They are classified

More information

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS 1. Define an accumulator and explain its function A hydraulic accumulator is a device that stores the potential energy of an incompressible fluid

More information

Self-aligning ball bearings

Self-aligning ball bearings Self-aligning ball bearings Designs... 470 Basic design... 470 Sealed bearings... 470 Bearings with an extended inner ring... 472 Bearings on sleeves... 473 Self-aligning ball bearing kits... 474 Appropriate

More information

Minor losses include head losses through/past hydrants, couplers, valves,

Minor losses include head losses through/past hydrants, couplers, valves, Lecture 10 Minor Losses & Pressure Requirements I. Minor Losses Minor (or fitting, or local ) hydraulic losses along pipes can often be estimated as a function of the velocity head of the water within

More information

VX Series Pumps Rotary Lobe Pumps designed for abrasive and viscous liquids. HIGH PERFORMANCE PUMPS DESIGNED FOR TOUGH APPLICATIONS ENGINEERED TO WORK

VX Series Pumps Rotary Lobe Pumps designed for abrasive and viscous liquids. HIGH PERFORMANCE PUMPS DESIGNED FOR TOUGH APPLICATIONS ENGINEERED TO WORK ENGINEERED TO WORK HIGH PERFORMANCE PUMPS DESIGNED FOR TOUGH APPLICATIONS VX Series Pumps Rotary Lobe Pumps designed for abrasive and viscous liquids. Industry Agriculture Mining Biogas Agriculture Wastewater

More information

Series TMM Axial Piston Motor. Technical Information

Series TMM Axial Piston Motor. Technical Information Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer

More information

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999 CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.

More information

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C) HVAC SYSTEM (HEATER, VENTILATOR, AND A/C) HEATER SYSTEM 1. Heater System A: GENERAL A semi-center type integrated air conditioning unit is used, where a high performance heater core and an evaporator core

More information

CG-1171-20 PTFE Diaphragm Liquid Transfer Pump

CG-1171-20 PTFE Diaphragm Liquid Transfer Pump 3800 N. Mill Road Vineland, NJ 08360 Phone: 800.843.1794 Fax: 800.922.4361 CG-1171-20 PTFE Diaphragm Liquid Transfer Pump This is the safety alert symbol. It is used to alert you to potential personal

More information

The Auto-tensioner Market and Technical Trends

The Auto-tensioner Market and Technical Trends NTN TECHNICAL REVIEW No.73 2005 Technical Article The Auto-tensioner Market and Technical Trends Satoshi KITANO Tadahisa TANAKA Tomokazu NAKAGAWA Automotive engines generally use accessory drive belts,

More information

DECANTER CENTRIFUGE. www.haus.com.tr CENTRIFUGE TECHNOLOGIES

DECANTER CENTRIFUGE. www.haus.com.tr CENTRIFUGE TECHNOLOGIES DECANTER CENTRIFUGE www.haus.com.tr CENTRIFUGE TECHNOLOGIES CENTRIFUGE TECHNOLOGIES MORE THAN A MACHINE: DECANTER A centrifuge decanter; consists of a solid cylindirical bowl rotating at high speed, a

More information

FAG Hydraulic nuts. Technical Product Information

FAG Hydraulic nuts. Technical Product Information FAG Hydraulic nuts Technical Product Information Contents Application 2 Design 2 Design variants 3 Pressure generators, connectors 4 Dimension tables for FAG hydraulic nuts (metric) 6 Dimension tables

More information

MECHANICAL PRINCIPLES OUTCOME 4 MECHANICAL POWER TRANSMISSION TUTORIAL 1 SIMPLE MACHINES

MECHANICAL PRINCIPLES OUTCOME 4 MECHANICAL POWER TRANSMISSION TUTORIAL 1 SIMPLE MACHINES MECHANICAL PRINCIPLES OUTCOME 4 MECHANICAL POWER TRANSMISSION TUTORIAL 1 SIMPLE MACHINES Simple machines: lifting devices e.g. lever systems, inclined plane, screw jack, pulley blocks, Weston differential

More information

Centrifugal Fans and Pumps are sized to meet the maximum

Centrifugal Fans and Pumps are sized to meet the maximum Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed

More information

HIGH TEMPERATURE TWIN SCREW PUMPS. By: David B. Parker Two Screw Product Engineer IMO Pump Warren Warren, Massachusetts

HIGH TEMPERATURE TWIN SCREW PUMPS. By: David B. Parker Two Screw Product Engineer IMO Pump Warren Warren, Massachusetts HIGH TEMPERATURE TWIN SCREW PUMPS By: David B. Parker Two Screw Product Engineer IMO Pump Warren Warren, Massachusetts David B. Parker is the Two Screw Product Engineer for IMO Pump - Warren, in Warren,

More information

Electric Motors and Drives

Electric Motors and Drives EML 2322L MAE Design and Manufacturing Laboratory Electric Motors and Drives To calculate the peak power and torque produced by an electric motor, you will need to know the following: Motor supply voltage,

More information

Class 5 to 7 Truck and Bus Hydraulic Brake System

Class 5 to 7 Truck and Bus Hydraulic Brake System Class 5 to 7 Truck and Bus Hydraulic Brake System Diagnostic Guide 1st Edition * 5+0 Important Service tes The information in this publication was current at the time of printing. The information presented

More information

Variable Displacement Pump AA10VSO

Variable Displacement Pump AA10VSO Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi

More information

RETROFIT N ROTORS FOR EFFICIENT OIL-FLOODED SCREW COMPRESSORS

RETROFIT N ROTORS FOR EFFICIENT OIL-FLOODED SCREW COMPRESSORS RETROFIT N ROTORS FOR EFFICIENT OIL-FLOODED SCREW COMPRESSORS N Stosic, Chair in Positive Displacement Compressors, I K Smith, Professor of Applied Thermodynamics and A Kovacevic, Research Fellow Centre

More information

PeakVue Analysis for Antifriction Bearing Fault Detection

PeakVue Analysis for Antifriction Bearing Fault Detection August 2011 PeakVue Analysis for Antifriction Bearing Fault Detection Peak values (PeakVue) are observed over sequential discrete time intervals, captured, and analyzed. The analyses are the (a) peak values

More information

TECHNICAL INFORMATION Bulletin

TECHNICAL INFORMATION Bulletin Peerless Pump Company 2005 Dr. M.L. King Jr. Street, P.O. Box 7026, Indianapolis, IN 46207-7026, USA Telephone: (317) 925-9661 Fax: (317) 924-7338 www.peerlesspump.com www.epumpdoctor.com TECHNICAL INFORMATION

More information

Example. Fluid Power. Circuits

Example. Fluid Power. Circuits Example Fluid Power Circuits To Enhance Symbol Reading Skills To Work On Circuit Reading Skills With Answers HI LO Pump Circuit 18 A1 B1 17 16 15 13 Set 14 2,000 PSI PG2 Set 500 PSI 12 11 7 8 10 PG1 9

More information

Rickmeier Solutions. Gear pumps for superior Lubrication

Rickmeier Solutions. Gear pumps for superior Lubrication Rickmeier Solutions Gear pumps for superior Lubrication P U M P E N T E C H N O L O G I E #1. Introduction Position and significance of Rickmeier products Rickmeier supplies pumps, valves and systems for

More information