FTTX Solutions. AT 300 Access Terminal Products. Benefits
|
|
- Denis Mathews
- 7 years ago
- Views:
Transcription
1 CommScope s FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, CommScope s FTTX solutions simplify network installation, maintenance and management from the central office/head end to the outside plant. AT 300 Access Terminal Solutions are designed to meet and serve the wide range of customer requirements, providing a robust, user friendly and cost-effective platform for delivering fiber optic service drops in FTTX deployment. Benefits Intelligent Design smart cable management system maximizes performance, prevents damage and allows for future growth. Practical Matches optical node terminal deployment to service request. Future-Proof Supports efficient service deployment, management and technology upgrades. Flexible provides for a wide number of service applications. 1
2 Access Network Diagram Loop Through Application DISTRIBUTION CABINET DROP CABLE FIBER ACCESS TERMINALS DISTRIBUTION CABLE BRANCH 48 DROP CABLES Multiport Service Terminal (MST) Application 2
3 8 Non-Metallic Pedestal Features Molded from polypropylene material which is lightweight and non-corrosive The unique, unobtrusive design provides and attractive profile for residential deployments Includes a winter drop access door Provides intuitive, flexible fiber cable management meeting all bend radius specifications Includes grounding for armored cables and toneable conduit Uses standard 216B tools Removing the cover is quick and easy a quarter turn with a can wrench releases the top for immediate access. The cover is self locking Cover can be ordered with either bell jar or condensation venting options Meets GR-13 and NEMA 6 requirements Includes a barrier plate which provides protection against ground moisture and rodents Capacity Accepts up to 96 loose tube or 144 ribbon fibers distribution cable Provides up to six hardened connectorized terminated drops or up to 24 spliced drops* Supports express pass-through or taper splicing Accomodates loose tube or ribbon fiber, dielectric and armored cables Supports 96 or less expressed through buffer tubes *May not reflect actual field practice CommScope recommends 6 drops per tray. 3
4 10.09 REF REF 8.24 REF REF REF FTTX Solutions 8 Non-Metallic Pedestal Fiber Maximum Distribution Maximum Drop Maximum Drop Panel Type Panel Type Description Splice Trays* Connectors Splice Trays** A Connectorized drop-termination B Spliced drop-pass through 2 N/A 2 * Splice trays can handle up to 12 heat shrink splices per tray or 2 ribbon heat shrink splices per tray ** CommScope recommends 6 drops per tray Ordering Information Description Part Number AT Non-Metallic Pedestals Pass-through spliced drop only FAT-YNB0012Y0-000G 2 Hardened adapters with pigtails. HS fusion splice FAT-YNA1200Y0-H02G 4 Hardened adapters with pigtails. HS fusion splice FAT-YNA1200Y0-H04G 6 Hardened adapters with pigtails. HS fusion splice FAT-YNA1200Y0-H06G AT MST Mounting Pedestal 8 Pedestal with bell jar cover MST-ACC-Y10 8 Pedestal with bell jar cover with grounding MST-ACC-Y10G *Additional configurations available. May require minimum order quantity. 4
5 11 Non-Metallic Pedestal Features Molded from polypropylene material which is lightweight and non-corrosive The unique, unobtrusive design provides and attractive profile for residential deployments Includes a winter drop access door and drop wire channel standard Provides intuitive, flexible fiber cable management meeting all bend radius specifications Includes grounding for armored cables and toneable conduit Uses standard 216B tools Removing the cover is quick and easy a quarter turn with a can wrench releases the top for immediate access. The cover is self locking Cover can be ordered with either bell jar or condensation venting options Meets GR-13 and NEMA 6 requirements Includes a barrier plate which provides protection against ground moisture and rodents Split base Capacity Accepts up to 144 loose tube or ribbon fiber distribution cable Provides up to eight hardened connectorized terminated drops or up to 24 spliced drops Supports express pass-through or taper splicing Accomodates loose tube or ribbon fiber, dielectric and armored cables Ordering Information Description Ordering Number AT Non-Metallic Pedestals Pass-through spliced drop only FAT-ZNB0012Y0-000G 4 Hardened adapters with pigtails. HS fusion splice FAT-ZNA1200Y0-H04G 6 Hardened adapters with pigtails. HS fusion splice FAT-ZNA1200Y0-H06G 8 Hardened adapters with pigtails. HS fusion splice FAT-ZNA1200Y0-H08G AT MST Mounting Pedestal 11 Mounting Pedestal MST-ACC-Z11 11 Mounting Pedestal with grounding MST-ACC-Z11G *Additional configurations available. May require minimum order quantity. 5
6 8 and 10 OEM Non-Metallic Pedestal Features and Benefits Split base allows ease of installation 10 added two unique functions MST splice center takes place of splice case Eliminates cost of splice case and hand hole 10 branch splice panel allows 144 splices (900 micron or higher) Value Added Features CommScope cable management Pedestal meets industry standards Drop cable clamp Grounding features User friendly for technical field Flexible management of buffer tubes Easy to use strength member clamp Ordering Information Description Part Number AT 300 ProForm 8 Non-Metallic Pedestals Pass-through spliced drop only FAT-RNB0012Y0-000G 2 Hardened adapters with pigtails. HS fusion splice FAT-RNA1200Y0-H02G 4 Hardened adapters with pigtails. HS fusion splice FAT-RNA1200Y0-H04G 6 Hardened adapters with pigtails. HS fusion splice FAT-RNA1200Y0-H06G 8 Hardened adapters with pigtails. HS fusion splice FAT-RNA1200Y0-H08G AT 300 ProForm 10 Non-Metallic Pedestals 144 branch splice, spliced drop FAT-JNF1200Y0-000G 2 Hardened adapters with pigtails. HS fusion splice FAT-JNA1200Y0-H02G 10 Hardened adapters with pigtails. HS fusion splice FAT-JNA1200Y0-H10G AT 300 ProForm 8 MST Mounting Pedestal ProForm 8 MST Mounting Pedestal ProForm 8 MST Mounting Pedestal with grounding MST-ACC-RO4 MST-ACC-R04G AT 300 ProForm 10 MST Mounting Pedestal ProForm 10 MST Mounting Pedestal ProForm 10 MST Mounting Pedestal with grounding MST mounting on drop, HS fusion splice on distribution MST-ACC-J04 MST-ACC-J04G FAT-JNG1200Y0-000G *Additional configurations available. May require minimum order quantity. 6
7 BD4 Metallic Pedestals Features Industry standard BD4 8 metallic pedestal provides access for splice connectorized drops Value Added Features CommScope cable management Pedestal meets industry standards Drop cable clamp Grounding features User friendly for technical field Flexible management of buffer tubes Easy to use strength member clamp 7
8 FTTX Solutions BD4 Metallic Pedestal Pedestal Cover Insert bulkhead for BD4 and BD Above Grade Level Security Fastener Base 9.0 Grade Level Ordering Information Description Ordering Number AT 300 BD4 Metallic Pedestals Pass-through spliced drop only FAT-4NB0012Y0-000G 4 Hardened adapters with pigtails. HS fusion splice FAT-4NA1200Y0-H04G 6 Hardened adapters with pigtails. HS fusion splice FAT-4NA1200Y0-H06G 8 Hardened adapters with pigtails. HS fusion splice FAT-4NA1200Y0-H08G Insert Bulkheads BD4 (no pedestal). Includes fiber management components. FAT-4EB0012Y0-000G BD5 (no pedestal). Includes fiber management components. FAT-5EH1200Y0-000G *Additional configurations available. May require minimum order quantity. 8
9 Accessories Ordering Information Description Ordering Number Splice Trays 12 fiber AT 300 splice tray FAT-FST-HS01 24 fiber AT 300 splice tray* FAT-FST-HS02 Sealing Kits 8 pedestal sealing kit FAT-ACC-SLKT1 12 pedestal sealing kit FAT-ACC-SLKT2 Mounting stakes Non-metallic 32 mounting stake ProForm/BD 42 mounting stake ProForm/BD 32 mounting stake MST-ACC-Y32S MST-ACC-J42S MST-ACC-J32S Replacement Moisture Barrier Plate Kit** 8 Non-metallic FAT-MBP-Y 11 Non-metallic FAT-MBP-Z 8 ProForm FAT-MBP-R 10 ProForm FAT-MBP-J *24 fiber splices with use of 250 micronfibers **Configured for use with AT 300 cable management systems 9
10 Ordering Help Guide Capacity (number Number of Moisture Split of drops) Size of cables splice trays barrier plate base Grounding Non-Metallic 8 inch Splice Direct Drop 6 96 fiber 4 Yes No Recommended 8 inch Splice connector/adapter 6 96 fiber 2 Yes No Recommended 8 inch MST 8 n/a None not required No Recommended 11 inch Splice Direct Drop fiber 4 Yes Yes Recommended 11 inch Splice Connector/adapter fiber 2 Yes Yes Recommended 11 inch MST 8 n/a None not required Yes Recommended OEM ProForm Non-Metallic 8 inch Splice Direct Drop fiber 10 Yes Yes Recommended 8 inch Splice connector/adapter fiber 5 Yes Yes Recommended 8 inch MST 8 n/a Not required Yes Recommended 10 inch Splice Direct Drop fiber 10 No Yes Recommended 10 inch Splice Connector/adapter fiber 5 Yes Yes Recommended 10 inch Splice direct Drop 144 Branch fiber 14 Yes Yes Recommended 10 inch MST 8 n/a None Not required Yes Recommended 10 inch MST with splicing capabilities fiber 5 Yes Yes Recommended BD4 Metallic Pedestals* 8 inch splice only fiber 7 No Yes Required 8 inch hardened connectors fiber 5 No Yes Required 8 inch non-harded connector fiber 5 No Yes Required *Can be sealed with catalog number FAT-ACC-SLKT1 Visit our website or contact your local CommScope representative for more information CommScope, Inc. All rights reserved. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. PS AE (11/15) [Revised from ]
FTTX Solutions. Multiport Service Terminal (MST) and Hardened Drop Cables. Benefits:
and Hardened Drop Cables CommScope s FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability,
More informationFTTX Solutions FDH 3000 Cross-Connect
TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions
More informationMultiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER
Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) Abstract Fiber-to-the-Premises (FTTP) networks increasingly
More informationSection 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1
Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader
More informationFACT OPTICAL DISTRIBUTION FRAME SYSTEM
Fiber Connectivity for Splice/Patch and Patch/Patch For almost 30 years, CommScope has led the industry with solutions such as FIST fiber management system, providing a system of fiber management from
More informationWall Mounted Products
Metallic Indoor PK Termination Boxes Prysmian Part Numbers: see below Metallic PK Termination Boxes are designed for the termination, branching and distribution of fibre optic cables in telecommunication,
More informationCOYOTE PUP CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 17" (152.4 mm x 431.8 mm)
FEBRUARY 2005 COYOTE PUP CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 17" (152.4 mm x 431.8 mm) Be sure to read and completely understand this procedure before applying product. Be sure to
More informationCabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
More informationCT-02 CABLE TRAY SYSTEMS
CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry
More information3M Fiber Optic Splice Closure 2178-LS Series with Gasket
3M Fiber Optic Splice Closure 2178-LS Series with Gasket Instructions for: 3M Fiber Optic Splice Closures 2178-LS Series 3M Flame Retardant Fiber Optic Splice Closures 2178-LS/FR 3M Cable Addition Kit
More informationE 2 O TM. (Electrical to Optical) Cable Solutions Guide. E2O Cable Solutions
E 2 O TM (Electrical to Optical) Cable Solutions Guide E2O Cable Solutions The confidence of being prepared. For today s cable multi-system operator (MSO) there are few absolutes. Two things you can count
More informationConduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
More informationSECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING
SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete
More informationPretium Connector Housings
Pretium Connector Housings A LANscape Pretium Solutions Product Applications Main cross connect, intermediate cross connects and telecommunications rooms Rack or equipment cabinet installations Data center
More information2178-S Fiber Optic Splice Case
2178-S Fiber Optic Splice Case Instructions March 1998 34-7041-6288-1-B 1 2 Table of Contents 3M 2178-S Splice Case Description... 4 1.0 General...4 2.0 Specifications...4 3.0 Kit Contents...5 3M 2178-S
More informationKSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES
KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES KSR-SK-DB The following installation procedures are suggested guidelines for the installation of in-line cable splices. They
More informationATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6
050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY
More informationSection 2 COYOTE Splice Case Series
COYOTE Splice Case Series: Section 2 Section 2 COYOTE Splice Case Series Table of Contents COYOTE Splice Case...2-2 Capacities...2-4 Accessories...2-5 Tools...2-7 COYOTE Splice Case for Hi-Count Applications...2-8
More informationFTTH ARCHITECTURE WHITE PAPER SERIES
Not all FTTH networks are built the same. Since construction and outside plant account for the majority of total network costs, getting the architecture right has a major impact on the business case. The
More informationFiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications
Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications Topics! Understanding Fiber Types! Powering your Remotes via Composite Fiber! Fiber Design
More informationHP 36-Port InfiniBand Switch Cable Management Kit Installation Guide
HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide HP Part Number: 574412-doc Published: May 2009 Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein
More informationDIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).
DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute
More informationGovernment. Network and Communications Infrastructure for Federal Government
Government Network and Communications Infrastructure for Federal Government Federal Government Network Infrastructure Challenges Network and communications infrastructures are mission-critical elements
More informationXL PREMIUM OIL COOLER KIT
-J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English
More informationSYSTIMAX 360 360G2 4U Fixed Rear Access Combination Shelf Instructions
Issue 7, April 2014 SYSTIMAX 360 360G2 4U Fixed Rear Access Combination Shelf Instructions General The SYSTIMAX 360 360G2 4U rear access fiber optic combination shelf mounts onto a standard 19-inch (483mm),
More informationSPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT
SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT The purpose of these specifications is to insure that there are minimum
More informationIT&T Infrastructure Standards
Technology Services IT&T Infrastructure Standards Version 1.5 17 th April 2015 Page 1 Table of contents 1 CHANGE HISTORY... 3 1.1 DOCUMENT HISTORY... 3 1.2 REVIEWERS... 3 1.3 APPROVALS... 3 2 INTRODUCTION...
More informationPatch Cords for Data Center Applications
Applications General use of patch cords includes the interconnection of the optical fiber cable plant with opto-electronic equipment, and/or the cross-connection between cable plant segments. Pigtails
More informationCADDSTAR V7.0 FEATURES AND FUNCTIONALITY
CADDSTAR V7.0 FEATURES AND FUNCTIONALITY CADDStar is a powerful GIS-based facilities management and network documentation software. By combining the drawing / mapping features of AutoCAD Map with a relational
More informationRequired Supplies for Installing Check Tag Assembly
Check Tag Assembly and Antenna Installation Instructions 411922-004 05/10 This document explains how to install and connect the check tag assembly and check tag antenna. Required Supplies for Installing
More informationStorage Area Management (SAM) Clutter-Free, Super-Efficient Network Infrastructure Management
Storage Area Management (SAM) Clutter-Free, Super-Efficient Network Infrastructure Management Current estimates indicate that the amount of data you manage, maintain and process is increasing at a rate
More informationOvercoming Space Challenges and Reducing Costs with Small-Diameter Cable Technology. White Paper
Overcoming Space Challenges and Reducing Costs with Small-Diameter Cable Technology White Paper Business and residential subscribers all over the world view bandwidth in the same way that many of them
More informationE Series. E Series. Category 6 and 5e. Features
E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.
More informationIndoor/Outdoor Tight-Buffered Cable Lowers Installation Costs, Reduces Time, and Increases Reliability
Indoor/Outdoor Tight-Buffered Cable Lowers Installation Costs, Reduces Time, and Increases Reliability Introduction Fiber optic cable that is capable of surviving the outdoor environment and meets the
More informationField-Installable Fusion Splice-on Connector
Economical Solution for Integrated Fiber Preparation Tool Demand. Field-Installable Fusion Splice-on Connector More Cost-effective than Mechanical Connector in All Aspects PCT/KR2010/65973 The solution
More informationCP2 Buried Cable Pedestal Initial & Rehab Installation Instructions
Printing 3 March 2008 CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions This instruction is intended for CP2 cable pedestal installations and replacements. The following tools will be
More informationThe color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.
10 Cables The cables referred to below are provided with standard single- and multimode fibers. Other commercially available fibers can be provided on request. The bare fibers are colored in all cases
More informationNew Direct Core Monitoring Fusion Splicer TYPE-71C+
INFOCOMMUNICATIONS New Direct Core Monitoring Fusion Splicer Makoto MIYAMORI*, Ryuichiro SATO, Kazufumi JOKO, Hideaki YUSA, Toshihiko HOMMA and Koji KASHIHARA ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
More informationAs today s evolving data centers
IT CORNER Next Generation Optical Fiber Connectivity Solutions for the Mission Critical Data Center BY BILL CHARUK As today s evolving data centers confront bandwidth capacity challenges, the migration
More informationManaging High-Density Fiber in the Data Center: Three Real-World Case Studies
Managing High-Density Fiber in the Data Center: Three Real-World Case Studies CHALLENGE In today s data center, fiber optic links have become more vital than ever for transmitting data to and from a large
More informationTubeTrace, ThermoTube
TubeTrace, ThermoTube and Custom CEMS Tubing Bundles INSTALLATION PROCEDURES English Units TubeTrace & ThermoTube Tubing Bundles Receiving, Storing and Handling... 1. Inspect materials for damage incurred
More informationRayClic Connection System Installation Instructions
F M -W RayClic Connection System Installation Instructions RayClic WARNING: Shock Hazard 718K Pipe Heating Cable with HWAT, IceStop, also Listed De-icing and and XL-Trace heating Snow Melting Equipment
More informationFiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable
Fiber Optic Cable Assemblies Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable 1 Cable assemblies used in patch panels (Fiber Distribution Units) are an essential interface
More informationFiber Optic Specifications
Fiber Optic Specifications All Fiber Optic shall be Corning Altos Single Mode OS1 Outdoor Loose Tube Gel Free Cable Corning Fiber Products only will be accepted and no substitutions or alternates will
More informationFiber Optics in Harsh Environment Applications
Fiber Optics in Harsh Environment Applications Table of Contents Industrial Testing Comparisons 2 Fiber Optics in Harsh Environment Applications 3 Oil & Gas Products 4 Mining Products 6 Manufacturing 8
More informationThe migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations
The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations White Paper www.commscope.com Contents Introduction 3 CommScope solution overview 3 InstaPATCH
More informationwww.commscope.com Data Center Topology Guide
www.commscope.com Data Center Topology Guide Data Center Areas 1 Network Operations Center (NOC) The network operations center or NOC is the location where control of all data center networking, server
More informationMassoud Sadeghi: massoud.sadeghi@faa.gov. (425)227-2117 Brett Portwood: brett.portwood@faa.gov (562)627-5350. Transport Airplane Directorate; ANM-117
Massoud Sadeghi: massoud.sadeghi@faa.gov FAA Aging Systems Program Manager Transport Airplane Directorate; ANM-117 (425)227-2117 Brett Portwood: brett.portwood@faa.gov FAA Technical Specialist for Safety
More informationInterceptor Optical Network Security System. Design Guide. Chapter 4: INTERCEPTOR Optical Network Security System Alarmed Carrier PDS
Interceptor Optical Network Security System } Chapter 4: INTERCEPTOR Optical Network Security System Alarmed Carrier PDS Copyright 2010 Network Integrity Systems, Inc. All rights reserved. The information
More information3M Wireless Infrastructure Solutions. Moving. Mobility. Forward
3M Wireless Infrastructure Solutions Mobility Moving Forward Building your future network As wireless technologies evolve from 2G to 3G to 4G, they stress the coverage and capacity of service providers
More informationInstaPATCH ZERO Solution Guide
SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving
More informationFiber Optic Cable. www.ptsupply.com marketing@ptsupply.com 800-238-7514
Fiber Optic Cable Optical fibers from a choice of major cable manufacturers are available in several grades to manage the bandwidth requirements of today's voice, data and video networks. Single Mode Enhanced
More informationFTTx Optical Fiber Cable for Easy Mid-Span Access ( EZremove )
INFORMATION & COMMUNICATIONS FTTx Optical Fiber Cable for Easy Mid-Span Access ( EZremove ) Toshio AKIYOSHI*, Keisuke OKADA, Hiroki ISHIKAWA, Toshiaki TAKAHASHI, Kenji ISOGAI, Kiyotaka NISHIOKA and Akio
More informationItems Supplied. Frequency. Designation Description / Delivery Unit Order Number
Fiber Optic Cleaver D6 For Single- and Multimode Fibers Diamond blade for highest cleave quality and long life (typically > 10,000 cleaves) Fiber cleave length: 3.5 to 15 mm Fiber diameter: 125 µm nominal
More informationTELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities
1 TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities Beginning in January 2010 TELUS began designing new subdivisions within the Top 48 population
More informationLynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)
Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages) 1. Be sure that your kit includes all the parts shown in the Check the Equipment section
More informationIn-Building Solutions. Wired for Wireless Solution. www.commscope.com
In-Building Solutions Wired for Wireless Solution www.commscope.com Applications: Corporate Offices and Campuses Hospitals Universities Multi-tenant High-Rise Office Buildings Hotels and Casinos Local
More informationCable management for rack-mounted systems
Cable management for rack-mounted systems technology brief, 2 nd edition Abstract... 2 Introduction... 2 Cable routing guidelines... 3 Separation of power and data cables... 3 Retention of excess cable...
More informationWhitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada
Whitepaper Modular Substation Cable Termination Design Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Abstract The methods for cable penetrations into modular industrial substations are
More informationTable of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8
Data Center Guide 1 Our Philosophy As a leader in the enterprise cable industry since our inception over three decades ago, we can help you implement the solution that will work best for your cabling infrastructure,
More informationBACKUP CAMERA JEEP COMMANDER/GRAND CHEROKEE
BACKUP CAMERA 1 JEEP COMMANDER/GRAND CHEROKEE 2 Call Out Description Parts Quantity 1 Tie Wrap-Nylon 6.9" Supplied in kit 12 2 Camera, Rear View Supplied in kit 1 3 Camera Extension Harness Connector Supplied
More informationREMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION
ENGLISH REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION INSTALLATION GUIDELINES For Freightliner Cascadia ISO 9001:2000 L 2653 Rev. 20090130 WARNING: Only trained technicians should perform
More informationLIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationMultiple Meter Installation - 200 Amperes Per Position -Single Phase, Self-contained
Overhead Meters TABLE OF CONTENTS D D Consumer Service Pole for Mobile Home Park Temporary Service -wire Single Phase D. Overhead Meter Installation - Single Phase D. Connection Diagram - Single Phase
More informationSECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such
More informationCable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia
Exel Composites Cable Support Systems offer engineers a structural product for solving many design and plant engineering problems, enabling long term reliable support of expensive and often critical cables.
More informationNavico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement
Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement This work instruction describes the methods and means for which to remove and reinstall optional scanner cable configurations
More informationMultiple Solutions for Connecting Multiple Dwelling Units (MDUs)
Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) 1 MDU Construction - Objectives and Approach The MDU Construction Techniques aims at investigating the key elements of the MDU Technology
More informationLED High Bay Light 100W
LED High Bay Light 100W CRI: Life Hours: LED Count: Net Weight: 100W 7,527lm (5,500K-6,000K) 70 20.25in(D) Reflector 140 Up to 50,000 hrs 1 High Power 10x10 LED Array Hanging Loop -40-113 -277VAC 1.00
More informationHP 16/18-Port Cable Management Kit Installation Guide
HP 16/18-Port Cable Management Kit Installation Guide Abstract This document describes how to attach the HP 16 Port or 18 Port Cable Management Kit to an HP rack. The cable management bracket is designed
More informationELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS
Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document
More information5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
More informationFiber-to-the-Home/FTTH
Hands-On Design, Installation, Maintenance & Troubleshooting Active and Passive Optical Networks Course Description This Hands-On 2-day course is designed to provide technicians with Hands-On practical
More informationHEAT SHRINK RAYCHEM PRODUCT TECHNOLOGY A PROVEN TRACK RECORD OF SOLVING THE WORLD S HARSHEST CHALLENGES
ENERGY /// HEAT SHRINK RAYCHEM PRODUCT TECHNOLOGY HEAT SHRINK RAYCHEM PRODUCT TECHNOLOGY A PROVEN TRACK RECORD OF SOLVING THE WORLD S HARSHEST CHALLENGES For more than 60 years, Raychem products from TE
More informationINSTALLATION INSTRUCTIONS. 6108 Air Spring Kit 2011+ Ford F250 Single Wheel 4WD 2011+ Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)
INSTALLATION INSTRUCTIONS 6108 Air Spring Kit 2011+ Ford F250 Single Wheel 4WD 2011+ Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113) Thank you for purchasing a quality Hellwig Product. PLEASE
More informationAlliance System Ordering Guide
Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers
More informationFinance. Network Infrastructure Solutions for Financial Institutions
Finance Network Infrastructure Solutions for Financial Institutions Financial Network Infrastructure Challenges Financial institutions are unusually demanding environments for technology. At any point
More informationThe Need for Low-Loss Multifiber Connectivity
WP_LowLoss_D_B 10/13/14 2:08 PM Page 2 The Need for Low-Loss Multifiber Connectivity In Today s Data Center Optical insertion loss budgets are now one of the top concerns among data center managers, especially
More information2178-S Fiber Optic Splice Case and Accessories
2178-S Fiber Optic Splice Case and Accessories Tech Report October 1996 80-6109-3154-7 1 Contents: 1.0 Product Description... 3 2.0 Test Program Overview... 4 3.0 Environmental Tests... 5 4.0 Mechanical
More informationFCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2
Product Family: Product: Fibre: LANscape Hardware Solutions FCS-FCT-FCP Housings and Connector Panels InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2 Applications Corning Cable
More informationOWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
More informationCabling Services (price per pull) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5
BryComm, LLC -SDD-1901 Cabling Services (per pull) - Labor Only STANDARD TIME The price per cable pull represents all labor to include fishing walls, running cable through modular furniture, terminating,
More informationSTATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007
804.01 Description 804.02 General 804.03 Materials 804.04 Fan-Out Kit 804.05 Drop Cable 804.06 Fiber Optic Patch Cord 804.07 Termination Panel 804.08 Fusion Splice 804.09 Fiber Optic Connector 804.10 Splice
More informationInstallation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits 541 0812 and 541 0868
Instruction Sheet 10-2004 Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits 541 0812 and 541 0868 PowerCommand is a registered trademark of Cummins Inc. InPower
More informationPSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS
PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS AC AND DC GENERATOR SCHEMATIC ENGINE GENERATOR ASSEMBLY REF Description QTY PSS10 PSS12 1 Engine, Honda GX620K1VXC2 Code 637220 1 99779-000 GX670VXC2 Code 637220
More informationTOYOTA Tundra 2007 - BACK-UP CAMERA SYSTEM Preparation
Preparation Part Number(s): PT233-34070, PT923-35070-11, PT923-35070-43 NOTE: Part number of this accessory may not be the same as part number shown. Back Up Monitor Kit Contents PT923-35070-11 / PT923-35070-43
More informationExpanding a 40-Type Cabinet
Expanding a 40-Type Cabinet using the 3M Add-On Terminal 4220P 400-Pair and Jumper Trough Instructions January 2006 Table of Contents 1.0 General... 3 2.0 Cabinet Overall Descriptions... 3 3.0 Tools Required...
More informationInstallation Instructions
Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply
More informationEngage Coupler. Engage Coupler Chase
TECHNICAL BRIEF Wire Management in an Enphase System The Enphase Microinverter System installs much more quickly than other PV (photovoltaic) system technologies. This is partly due to the plug-and-play
More informationSolar Power Solutions
Solar Power Solutions Wire and Cable Photovoltaic Connectors Combiner Boxes Fuses Grounding Power Connectors Physical Support Products Cable Ties Supply Chain Solutions Products. Technology. Services.
More information3M Scotchcast Mine and Portable Cable Splice Kit 8096-4
3M Scotchcast Mine and Portable Cable Splice Kit 8096-4 Installation Instructions 1.0 Kit Contents: 2 Funnels 3 EPDM Rubber Cold Shrink Cold Shrink Insulator 1 Wrap-around Mold Assemblies 2 Rubber Mold
More informationVersatile, Scalable Cable Protection in Data Centers and Central Offices
APPLICATION GUIDE FOR FIBERR UNNER CABLE ROUTING SYSTEM Versatile, Scalable Cable Protection in Data Centers and Central Offices PANDUIT is a Technology Developer Partner for Storage Networking Hardware.
More informationPhysical & Network Security Infrastructure Solutions
Physical & Network Security Infrastructure Solutions people. passion. expertise. gocsc.com What is the Secure(it) Program? Secure(it) is a bundle of the industry s latest solutions, designed to protect
More informationCOMMERCIAL GAS DRYER
COMMERCIAL GAS DRYER MODELS CGM2941TQ0 CGM2941TQ1 07 08 Litho in U.S.A. (LT)(mek) c 2008 WHIRLPOOL CORPORATION Part No. Rev. B BULKHEAD PARTS (White) (White) 2 BULKHEAD PARTS 1 Literature Parts 8563800
More informationSTATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE AND COMPONENTS. January 15, 2016
804.01 Description 804.02 General 804.03 Materials 804.04 Warranties 804.05 Fiber Optic Cable 804.06 Fan-Out Kit 804.07 Drop Cable 804.08 Fiber Optic Patch Cord 804.09 Fiber Termination Panel 804.10 Fusion
More informationEVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility
EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001 2014 Class 2800 CONTENTS Description............................................ Page 2 Outdoor
More informationInstallation Guide for Artic Air 24 Volt R134A Air Conditioner
Installation Guide for Artic Air 24 Volt R134A Air Conditioner Rev 004 April 20, 2014 There are five objectives to installing the Artic Air unit: 1) The primary wiring from the battery, 2) The controller
More informationIntroduction. Technology Solutions Maps. Using the Solutions Map 2.1
Introduction This section illustrates a complete solution by industry segment. We designed each map to guide you in selecting the right components for the solution you are building. The map helps you identify
More informationCustomized Server Cabinets
GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.
More information