Support of Transmission Line Structures Using HELICAL ANCHORS and PILES
|
|
- Susanna Griffith
- 7 years ago
- Views:
Transcription
1 Support of Transmission Line Structures Using HELICAL ANCHORS and PILES
2 MITCHELL SCREW PILE & MOORING Maplin Sands Lighthouse st Recorded use was by Alexander Mitchell ( ) in 1836 for Moorings and was then applied by Mitchell to Maplin Sands Lighthouse in England in 1838 U.K. Patent No (renewed 1847) U.S. Patent No April 1, 1845
3 Advantages Screw Anchors/Piles Quick, Easy Turnkey Installation Immediate Loading Small Installation Equipment Pre-Engineered System Easily Field Modified Torque to Capacity Correlation Install in Any Weather Solution for: Restricted Access Sites High Water Table Weak Surface Soils Environmentally Friendly No Vibration No spoils to Remove No Concrete
4 Helical Piles Why Use Helical Piles? 1. Economically handle the loads Uplift Compression Shear and overturning moment due to wind loads 2. Resists Up-Heave due to: Ground Freeze Expansive Soils
5 3. Environmental Benefits: No excavation Eco system simplified permitting Removable, reuse or recycle Quiet installation Soil compaction without changing mean elevation 4. Fast, simple, low cost installation Standard excavation equipment Inexpensive Tooling High Production rates 100+ piles/day/crew Load the piles immediately Minimal training needed (a specialty contractor is not required)
6 Square Shaft Helical Products CHANCE SCREW ANCHORS SS5,SS150, SS175, SS200 & SS225
7 SQUARE SHAFT 356 mm 36 3 m 305 mm 254 mm 203 mm CHANCE Helical Anchors & Piles Tension/Compression Lead Section Helical Extension Extension
8 SQUARE SHAFT Torsion & Tension Ratings SS125 4,000 ft-lb 50 kip SS5 5,500 ft-lb 70 kip SS150 7,000 ft-lb 70 kip SS175 10,500 ft-lb 100 kip SS200 16,000 ft-lb 150 kip SS225 23,000 ft-lb 200 kip kgf kgf kgf kgf kgf kgf CHANCE Helical Anchors & Piles Tension/Compression Shaft Grade 70,000 psi (483 mpa) & 90,000 psi (621 mpa) minimum Helix Grade 50,000 psi (345 mpa) & 80,000 psi (552 mpa)
9 Square Shaft Series Product Ratings Product Series Torque Rating ft-lb (N-m) Ultimate Tension Strength* lb (metric ton) Tension Capacity in Soil** lb (metric ton) SS (7500) (32) (25) SS (9500) (32) (32) SS (14240) SS (21700) SS (31200) (45) (45) # (68) (68) # (91) (91) # * Based on Mechanical Strength of Coupling. ** Based on Shaft Torque Rating Tension/Compression = Shaft Torque Rating x K t Default K t for the SS Series = 10 ft -1 # Limited by Mechanical Strength of Coupling
10 Pipe Shaft Helical Products CHANCE SCREW PILES RS2875, RS3500, RS4500,RS8625, RS10750
11 ROUND SHAFT HELICAL PILES Torsion and Capacity Ratings CHANCE Helical Anchors & Piles Tension/Compression RS ,500 ft-lb 60 kip RS ,000 ft-lb 90 kip RS ,000 ft-lb 120 kip RS ,000 ft-lb 140 kip Shaft Grade 50,000 psi (345 mpa) minimum Helix Grade 50,000 psi (345 mpa) & 80,000 psi (552 mpa)
12 SS to PIPE SHAFT COMBO PILE 1-1/2 Square Shaft to RS /4 Square Shaft to RS Square Shaft to RS /4 Square Shaft to RS
13
14
15 HELICAL PILES WITH GROUTED SHAFTS HELICAL PULLDOWN Micropile Characteristics ,000 ft lbs. Installation Torque Design Tension Loads up to 100 kip (445 kn), Design Comp. Loads up to 200 kip (890 kn) Helix Dia: 6 (152 mm) 8 (203 mm) 10 (254 mm) 12 (305 mm) 14 (356 mm), 16 (406 mm) Prevents Buckling Increases Capacity Corrosion Resistance Uses Type SS (Square Shaft) and RS (Pipe Shaft) Material
16 Grouted Helical Piles These Techniques Result in Grouted Helical Anchors
17 Grout Column in Sand Usually Cannot extract by direct pull Must look at grout formation in sands by excavation
18 CONSIDERATIONS Requires Grout and Displacement Plates Estimate 10% TO 15% additional cost based on 30 ft. pile Takes time and labor to mix grout Potential for Draw-Down in Compressible Soils. Potential for Negative Skin Friction in Expansive and Frozen Soils. Hydrostatic Pressure Required to Keep Grout Column Open. Usually Limited to Soils with SPT Blow Counts < 20 blows/ft
19 LARGE DIAMETER PIPE PILES 219 mm 168 mm RS ,000 ft-lb 300 kip RS ,000 ft-lb 200 kip kgf kgf
20 LARGE DIAMETER PIPE COUPLING
21
22
23 ALLOWABLE CAPACITY Allowable Capacity Evaluated for Compression, Tension, Transverse Shear or a Combination of All Three Four Structural Elements Bracket Capacity Shaft Capacity Helix Capacity Soil Capacity
24 Screw Anchor/Pile Capacity in Soil Information Needed Clay & Silt (Fine Grain Soil) Cohesion (shear strength) Unit weight N value, or blow count from Standard Penetration Test (SPT) Sand & Gravel (Granular Soils) Phi (φ) angle (angle of internal friction) Unit weight N value from Standard Penetration Test (SPT) Water Table Elevation
25 Soils Suitable for Screw Anchor/Piles Granular Soils - Sand & Gravel
26 Soils Suitable for Screw Anchor/Piles Cohesive Soil Clay and Silt
27 Soils Not Suitable for Screw Anchor/Piles Not For Helical Anchors/Piles! Solid Rock
28 Plate Bearing Capacity Model Minimum Depth 5D UC f Total Capacity Equal to Sum of Individual Helix Bearing Capacities D Model valid for both tension and compression D 1 Helix Spacing Helix Spacing 3D 1 Min. Depth 5D (Default) Capacity (UC f ) Due to Friction Along Shaft = Zero.
29 Individual Helix Bearing Method Q ULT = ΣQ H where: Q ULT = Total Multi-Helix Anchor Capacity Q H = Individual Helix Capacity Q H = A H (CN C + qn q ) Q S - where: A H = Projected Helix Area Q S = Upper Limit Determined by Helix Strength
30 HeliCAP v2.0 Helical Capacity Software Provides the Theoretical Bearing Capacity - Based on Soil Strength For design purposes, Hubbell/Chance distributes a software package to engineers. This program, HeliCAP -v2.0, uses soil parameters chosen by the engineer to compute and output theoretical anchor capacities for design. Available from Chance Civil Construction Web Site
31 HeliCAP v2.0 Software HeliCAP v2.0 Workpage US Units
32 LOAD TRANSFER Friction & Bearing Two Mechanisms Side Friction, P s (skin friction) Toe-bearing Resistance, P t (point-bearing resistance,end bearing resistance, tip bearing resistance)
33 FRICTION CAPACITY EQUATION Q f = Σ[πDf s L f ] where: D = Diameter of Grouted Pile Column f s = Sum of Friction and Adhesion between Soil and Pile (force/area) L f = Incremental Pile Length over which πd and f s are Taken as Constant
34 HeliCAP Friction Module No Need to Do Hand Calcs Let HeliCap Do it for You!!
35 Skin Friction from Various Sites Project Location Soil Description Average Friction Resistance (ksf) AT/FP Site Improvements Norfolk Naval Shipyard, Portsmouth, VA Soft/loose to medium silty clays and sands under medium-dense fill 1.8 McDuffie Island Coal Terminal Mobile, AL Soft clay over sand of increaseing blow count with depth 1.2 R.W. Harris Site Clearwater, FL Loose, wet sand w/ limestone lenses over stiff clay Eaton Dam site Leadwood, MO Sand tailings - φ = 33, γ = 105 pcf, c= Phillies Baseball Stadium Philadelphia, PA Loose to medium dense sand fill over soft to medium stiff clay 0.64 S & ME Office Building Mt. Pleasant, SC Soft clay and/or loose fine grained sands w/ fines Cooper Marl ft below surface 0.7 Duhon Machinery Yard Kenner, LA Soft clays and silts with occasional sand layers 0.5 Harrah s Casino St. Louis, MO Stiff to soft clay fill over loose to medium-dense sand 1.2
36 Lateral Analysis Using Finite Difference Methods (LPILE) Limiting Criteria: 1. Pile-Head Deflection 2. Bending Moment 3. Shear
37
38 Torque to Capacity Correlation The Torque Required to Install a Helical Pile or Anchor is Empirically Related to Its Ultimate Capacity. Q ult = K t T Where: Qult = Ultimate Capacity [lb (kn)] K t = Empirical Torque Factor [ft-1 (m-1)] Default Value = 10 (33) for Type SS Default Value = 8 (26) for 2-7/8 Pipe Shaft Default Value = 7 (23) for 3-1/2 Pipe Shaft Default Value = 6-7 (20-23) for 4-1/2 Pipe Shaft Default Value = 4-5 (20-23) for 6 & 8 Pipe Shaft T = Installation Torque, [ft-lb (kn-m)]
39 Digital Torque Indicator New Product Measures Torque in ft-lb. Continuous Duty Torque Indicator, or Can be Used to Calibrate Pressure Gauge on Installation Equipment Wireless Unit available 1Q 2014
40 Helical Pile Installation
41 INSTALLATION LOG TORQUE VS. DEPTH SSI75 w/ 8, 10, 12 & 14 in HELICES, LENGTH 31 FT VERTICAL INSTALLATION CLAY SOIL Torque at Termination: Best if Steady or Increasing TORQUE (ft-lb) DEPTH (ft)
42 Example of Installation Torque Depth (ft) Torque Data- Depth = 15ft a-AG, Helix Diameter = 8" Torque (ft-lb)
43 Test Date: Oct 2005 Centralia, MO Load vs. Deflection Load (kip) Type SS /4 Square Shaft Pile Length = Deflection (in) TP-7 PL/AE PL/AE + 0.1D Average Torque = 5733 ft-lb Kt = 12.2
44 Torque Correlation AC358 Section Torque Correlation Verification Conforming Systems 1.5 & 1.75 Square Shaft Kt = /8 OD Pipe Shaft Kt = 9 3 OD Pipe Shaft Kt = 8 3-1/2 OD Pipe Shaft Kt = 7 Verification Requires 14 Full-Scale Load Tests in Soil Non-Conforming Systems Verification Requires 28 Full-Scale Load Tests in Soil
45 Corrosive Environments Soil Type Granular soils sand & gravel Fine grained clay and silts Organics Contaminants Disturbed versus undisturbed Moisture Content Corrosion potential increases with an increase in moisture content Saturated soils with little or no oxygen have reduced corrosion potential ph Neutral soils with ph~7 have lower corrosion potential Resistivity Used to determine corrosion potential Low resistivity means higher corrosion potential
46 Corrosion Protection Typical Life Expectancy for Galvanized Steel Screw Anchors/Piles in Soil Exceeds 100 Years Based on soils that are considered mildly corrosive 1/8 inch (3.2 mm) loss of material on shaft Sacrificial loss of steel Corrosion allowance Hot dipped galvanizing or other coatings (passive control) Zinc Nylon coated bolts Bituminous or asphaltic coatings Sacrificial anodes (active control) Magnesium or zinc bags
47 Applications Transmission and Substation
48 WIND PRESSURE ON POLE Loads Steel Pole Line Single Mast Mono-Pole Line Deflected Shape
49 Wind Pressure (P) LOAD at GROUNDLINE Moment Large Shear Moderate Compression - Light Moment (M) Force (F)
50 2 POLE STRUCTURE Moment Moderate Shear Moderate Compression - Light Deflected Shape 2 Pole Structure
51 H FRAME STRUCTURE Moment Low Shear Moderate Compression Light Tension - Light Deflected Shape H-Frame Structure
52 SELF SUPPORT LATTICE STRUCTURE Moment Low Shear High Compression High Tension - High
53 SELF SUPPORT LATTICE STRUCTURE Moment Low Shear Light Compression High Guy - Moderate
54 Saskpower 230 kv Transmission Line Structure: Location: Soil: clay. Frost Depth: Guyed Steel H-Frame Construction Saskatoon to Regina, Saskatchewan Medium dense sand and gravel. Some isolated pockets of stiff 7 feet
55 Saskpower 230 kv Transmission Line Type 1 Anchorage 221 kn (50 kip) Acceptance Criteria: No anchor creep greater than 12 mm (1/2 inch) allowed after 60 seconds at this pull-out load. Type 2 Anchorage 275 kn (62 kip) Acceptance Criteria: No anchor creep greater than 12 mm (1/2 inch) allowed after 60 seconds at this pull-out load. Type 3 Anchorage 400 kn (90 kip) Acceptance Criteria: No anchor creep greater than 12 mm (1/2 inch) allowed after 60 seconds at this pull-out load.
56 Saskpower 230 kv Transmission Line Type 1 (Option 2) 221 kn (50 kip) SS175 w/ 8, 10 & 12 Installation Torque 6,000 ft-lb
57 Saskpower 230 kv Transmission Line Type kn (62 kip) SS175 w/ 8, 10 & 12 Installation Torque 6,700 ft-lb Option w/14 helix extension
58 Saskpower 230 kv Transmission Line Type kn (90 kip) SS200 w/ 8, 10, 12 & 14 Installation Torque 10,000 ft-lb Option w/14 helix extension
59 Saskpower 230 kv Transmission Line
60 RIO MADEIRA PROJECT 600kV dc Line June 2010 Update
61 D Porto Velho Araraquara 1 600kV Line CC 2375km - Consorcio Madeira G Porto Velho Araraquara 2 600kV Line CC 2375km Consorcio Integração Norte B Cuiaba Rio Verde 500kV Line HB 602km - Cymi
62 Rio Madeira 600 kv Transmission Line
63 Rio Madeira 600 kv Transmission Line CHANCE Type SS200 Helical Anchor
64 Rio Madeira 600 kv Transmission Line
65 Ejemplo para uso en anclaje de Tirante Linha Porto Velho-Araraquara Tipo: Estaca maciza Modelo SS200 Carga ruptura: 68t Torque Instalacion: 14,000 ft-lbs
66 Tension Test to Ultimate Capacity
67 Tension Test Type SS200 Anchor
68 Guy Anchor Test Rio Madeira - Brazil 500 kv Guyed Structure Max Test Load: 130 kip Type SS200 Anchor
69 Engevix - Brazil Transmissora Sul Litoranea De Energia, S.A. LT 525 kv Marmeleiro Povo Novo
70 Helical Pile Supported Mast Base Type SS175/RS3500 Helical Pile
71 Helical Guy Anchor Supported Tower Type SS200 Anchors
72 Helical Pile Supported Tower Base 4-Legged Self-Support Type SS175/RS3500 Helical Piles
73
74 Compression Test Type SS175/RS3500 Helical Pile
75 San Pedero Sula - Honduras Caracol Knit kv Electrical Feed for Biomass and Textile Plants
76 Three Self-Support Towers Helical Piles: CHANCE Type SS175/RS Combo Piles Training Installation Crew at first Tower Site
77 Pouring Pile Caps
78 Loads: Approx. 170 kip per Leg Four Helical Piles per Leg Production Rate: One tower/per day (16 piles per day)
79 Xcel Energy Stinson-Bayfront Helical Pile Foundations Line 3315, 32.1 mile rebuild 115 kv H-Frame
80 Structure Types Running Angle Deadend
81 Xcel Energy Stinson - Bayfront 115 kv Full Scale Load Tests Hager City, WS
82 Load Cases
83 Forces in Helical Piers (KIPS) Axial Force is positive for uplift and negative for compression Deadend Deadend Reactions Case 1 Case 2 Pier Vertical Shear Y Shear Z Vertical Shear Y Shear Z
84 Running Angle Reactions Forces in Helical Piers (KIPS) Axial Force is positive uplift and negative compression Running Angle Case 3 Case 4 Pier Vertical Shear Y Shear Z Vertical Shear Y Shear Z
85 Deadend Load Case 1 100%
86 Deadend Case Case 100%
87 Running Angle Case 100% Case 100%
88 Test Deflections Type Pole Top Flange Plate Pile (up) Pile (down) Pile Lateral Deadend Running Angle
89 Xcel Energy Stinson - Bayfront 115 kv
90 Steel Tri-pod Grillage
91 Hydro One Networks Tower Foundation Replacement with Helical Piles 500 kv Guyed V-Shaped Structures
92 Hydro-One Networks 500 kv Towers Note Jig that Allows the Track-hoe Operator Visually Check the Installation Angle
93 Hydro-One Networks 500 kv Towers Piles Installed and Awaiting Cut-off
94 Hydro-One Networks 500 kv Towers Tower Structure Being Lifted off Old Grillage Foundation
95 Hydro-One Networks 500 kv Towers Tower Grillage Complete and Ready for Backfill
96 Self-Supported Structures
97 Four Leg Self Support Tower
98 Three Screw Piles per Leg
99 Winter Construction
100 Grillage Fabricated in the Field
101 Monopole in Remote Site
102 Screw Pile Supported Steel Grillage
103 Guyed Telecom Tower 330 Guyed Tower At Morganza, LA Fan/Spreader Plate Assembly 7 Guywires to 4 SS5 Series Anchors Required Total Ultimate Capacity = kips
104 Installation Machine Swamp Buggy South Bend, LA Installation of 6 Guy Anchor Cluster Resultant Design Load = 95.0 kips
105 Multi-Screw Pile Concrete Pile Cap South Bend, LA Guyed Tower 12 RS Series Piles for Tower Mast Required Ultimate Capacity per Pile = 70.0 kips
106 Multi-Screw Anchor Guy Point in Concrete Guyed Tower at Abita Springs, LA 4 SS175 Series Anchors at the Inner Guywire Cluster Resultant Load = kips 4 SS175 Series Anchors at the Outer Guywire Cluster Resultant Load = 94.0 kips
107 Multi-Screw Piles with Concrete Cap SST at Bayou Blue (Houma), LA 12 Stepped Helical Pulldown Micropile per tower leg Ultimate Capacity per pile = 95.0 kips Load Tested to over kips in tension Installed Depths = 70-0
108 Installation Equipment SST at Bayou Blue (Houma), LA 12 Stepped Helical Pulldown Micropile per tower leg Pile Installation using John Deere
109 Augmentation of Existing Foundation
110 Instant Screw Pile Foundations Roadway Lighting, Parking Lots, Site Lighting Maximum installing torque 6 5/8 O.D. 15,000 ft-lb. 8 5/8 O.D. 20,000 ft-lb. 10 3/4 O.D. 20,000 ft-lb.
111
Comprehensive Design Example 2: Foundations for Bulk Storage Facility
Comprehensive Design Example 2: Foundations for Bulk Storage Facility Problem The project consists of building several dry product storage silos near an existing rail siding in an open field presently
More informationTransmission Foundations. helical piles and guy anchors for transmission structures. www.hubbellpowersystems.com
Transmission Foundations helical piles and guy anchors for transmission structures www.hubbellpowersystems.com Grid locked on your transmission job? Instant Foundation helical piles go places concrete
More informationFigure A-1. Figure A-2. continued on next page... HPM-1. Grout Reservoir. Neat Cement Grout (Very Flowable) Extension Displacement Plate
Addendum HELICAL PULLDOWN Micropile (HPM) Introduction The HPM is a system for constructing a grout column around the shaft of a standard Helical Screw Foundation (see Figure A1). To begin the process,
More informationDESIGN, INSTALLATION AND TESTING OF HELICAL PILES & ANCHORS. Presented by: Donald A. Deardorff, P.E. CHANCE Civil Construction Centralia, MO USA
DESIGN, INSTALLATION AND TESTING OF HELICAL PILES & ANCHORS Presented by: Donald A. Deardorff, P.E. CHANCE Civil Construction Centralia, MO USA Historical Perspective 1 st Recorded Screw Pile was by Alexander
More informationSystem. Stability. Security. Integrity. 150 Helical Anchor
Model 150 HELICAL ANCHOR System PN #MBHAT Stability. Security. Integrity. 150 Helical Anchor System About Foundation Supportworks is a network of the most experienced and knowledgeable foundation repair
More informationNew construction Repairing failed or old foundations Retrofit foundations Permanent battered piers Machinery/equipment foundations
from New construction foundations don t have to be a headache. The CHANCE Helical Pier Foundation System gives you the performance of concrete without the drawbacks and liabilities of driven piles and
More informationStability. Security. Integrity.
Stability. Security. Integrity. PN #MBHPT Foundation Supportworks provides quality helical pile systems for both new construction and retrofit applications. 288 Helical Pile System About Foundation Supportworks
More informationHigh Capacity Helical Piles Limited Access Projects
High Capacity Helical Piles Limited Access Projects Tel 403 228-1767 Canada, USA, Russia Brendan ODonoghue 519 830-6113 Presentation Summary 1. Helical piles Background on large diameter shafts and helices
More informationStep 6 Buckling/Slenderness Considerations
Step 6 Buckling/Slenderness Considerations Introduction Buckling of slender foundation elements is a common concern among designers and structural engineers. The literature shows that several researchers
More informationThe Stabilizer TM. Benefits. www.griptite.com. Supplemental support system for sagging beams and floor joists within a crawl space
The Stabilizer TM Supplemental support system for sagging beams and floor joists within a crawl space Pre-drilled holes in steel plate allow for connection to beam or floor joists. Benefits Levels and
More informationFOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples
FOUNDATION DESIGN Proportioning elements for: Transfer of seismic forces Strength and stiffness Shallow and deep foundations Elastic and plastic analysis Foundation Design 14-1 Load Path and Transfer to
More informationStep 11 Static Load Testing
Step 11 Static Load Testing Test loading is the most definitive method of determining load capacity of a pile. Testing a pile to failure provides valuable information to the design engineer and is recommended
More informationPTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE
FORM A PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE The following suggested specifications are written as a guide to assist the specifier in writing his own specifications. Specific circumstances
More informationHelical Piles. A Practical Guide to Design and Installation
Brochure More information from http://www.researchandmarkets.com/reports/2216946/ Helical Piles. A Practical Guide to Design and Installation Description: An unbiased, comprehensive review of helical pile
More informationLEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900
More informationPole Guying More Complicated Than Meets the Eye. NRECA TechAdvantage 2014 Presented by Jason Settle, P.E. jason.settle@gdsassociates.
Pole Guying More Complicated Than Meets the Eye NRECA TechAdvantage 2014 Presented by Jason Settle, P.E. jason.settle@gdsassociates.com Pole Guying Strength of components NESC vs. RUS Guy Factor Grounding
More informationNow That s IDEAL. Now That s IDEAL. LISTEN. RESEARCH. DESIGN. DELIVER.
The Leading Edge SM At IDEAL, we try not to complicate things. We discover needs and problems, then work out solutions. It takes real teamwork to accomplish truly great things. That s you and us, working
More informationHelical Pier Foundation System U.S. Patents 5,011,336; 5,120,163; 5,213,448
Helical Pier Foundation System U.S. Patents 5,011,336; 5,120,163; 5,213,448 Technical Manual Contents Helical Pier Foundation System History Research and Development Advantages Theory of Foundation Anchor
More informationPage B-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 LOAD TESTS
Page B-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 Appendix B CONTENTS STATIC (TIEBACKS)... B-3 STATIC AXIAL (COMPRESSION/TENSION)... B-6 STATIC (LATERAL)... B-9 CAPACITY VERIFICATION
More informationHow to Design Helical Piles per the 2009 International Building Code
ABSTRACT How to Design Helical Piles per the 2009 International Building Code by Darin Willis, P.E. 1 Helical piles and anchors have been used in construction applications for more than 150 years. The
More informationDIVISION: 31 00 00 EARTHWORK SECTION: 31 63 00 BORED PILES REPORT HOLDER: HUBBELL POWER SYSTEMS, INC.
0 ICC ES Report ICC ES (800) 4 6587 (56) 699 054 www.icc es.org 000 Most Widely Accepted and Trusted ESR 794 Reissued 05/05 This report is subject to renewal 05/06. DIVISION: 00 00 EARTHWORK SECTION: 6
More information5/1/2013. Topics. The challenge is to better maintain native characteristics of soils during and after construction
PIN Foundations Topics Applications Design and Construction Flow Control Credits www.pinfoundations.com Copyright 2008, Pin Foundations, Inc. Curtis Hinman WSU Extension Faculty, Watershed Ecologist chinman@wsu.edu
More informationEngineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.
TM TM Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. SM The Leading Edge. 10 One Major Causes of foundation settlement or more conditions may
More informationHELICAL SCREW PILE FOUNDATIONS. Presented by: Laurence Boakes Azimuth Structural Engineering Ltd.
HELICAL SCREW PILE FOUNDATIONS Presented by: Laurence Boakes Azimuth Structural Engineering Ltd. Historical Perspective 1 st Recorded use of a Screw Pile was by Alexander Mitchell in 1836 for Moorings
More informationTransmission Foundations Case History : Helical piles Hydro One Networks Inc.
Transmission Foundations Case History : Helical piles Hydro One Networks Inc. www.hubbellpowersystems.com Late in 2008, an aerial patrol discovered three 500kV towers with partially-collapsed foundations
More informationPILE FOUNDATIONS FM 5-134
C H A P T E R 6 PILE FOUNDATIONS Section I. GROUP BEHAVIOR 6-1. Group action. Piles are most effective when combined in groups or clusters. Combining piles in a group complicates analysis since the characteristics
More informationDesigned and Engineered to Perform
History EARTH CONTACT PRODUCTS, L.L.C., is a family owned company, based in Olathe, Kansas. This company was built upon Don May s U.S. Patented fourth-generation Steel Piering System that has led to the
More informationATLAS RESISTANCE Pier Foundation Systems
ATLAS RESISTANCE Pier Foundation Systems Foundation Repair Systems for Civil Construction Applications: Residential, Commercial, Industrial Atlas Resistance Piers have been used to restore and/or stabilize
More informationENCE 4610 Foundation Analysis and Design
This image cannot currently be displayed. ENCE 4610 Foundation Analysis and Design Shallow Foundations Total and Differential Settlement Schmertmann s Method This image cannot currently be displayed. Strength
More informationMETHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
More informationINDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode
INDIRECT METHODS SOUNDING OR PENETRATION TESTS STANDARD PENETRATION TEST (SPT) Reference can be made to IS 2131 1981 for details on SPT. It is a field edtest to estimate e the penetration e resistance
More informationDynamic Load Testing of Helical Piles
Dynamic Load Testing of Helical Piles ANNUAL KANSAS CITY SPECIALTY SEMINAR 2014 JANUARY 10, 2014 Jorge Beim JWB Consulting LLC Pile Dynamics, Inc. Main Topics Brief description of the Dynamic Load Test
More informationSAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS
Page 1 of 9 SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS 1. GENERAL REQUIREMENTS 1. Description of Work: This work consists of furnishing all materials, equipment and
More informationload on the soil. For this article s examples, load bearing values given by the following table will be assumed.
How Many Piers? By Gary Collins, P.E. A clear-cut guide to helical pier spacing Introduction Helical pier spacing is not an exact science. How many does it take to support a structure adequately or repair
More informationPRODUCT DRAWINGS AND RATINGS Section 7
PRODUCT DRAWINGS AND RATINGS Section 7 CONTENTS ATLAS RESISTANCE PIERS 7-1 PIER PIPE SHAFTS 7-1 REMEDIAL REPAIR BRACKETS for ATLAS RESISTANCE PIERS 7-2 ACCESSORIES for ATLAS RESISTANCE PIERS 7-6 CHANCE
More informationproduct manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer
HS-4210_MAN_09.08 product manual HS-4210 Digital Static Cone Penetrometer Introduction This Manual covers the measurement of bearing capacity using the Humboldt Digital Static Cone Penetrometer (DSCP).
More informationMicropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation
Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation Jeff R. Hill, P.E. Hayward Baker Inc. 111 W. Port Plaza Drive Suite 600 St. Louis, MO 63146 314-542-3040 JRHill@HaywardBaker.com
More informationWorld Leader in earth anchoring since 1907. for Residential and Commercial Construction and Repairs
Bulletin 01-9901 Rev. 02/03 POWER SYSTEMS, INC. World Leader in earth anchoring since 1907 INSTANT FOUNDATION Systems for Residential and Commercial Construction and Repairs with the speed of steel for
More informationOutline MICROPILES SUBJECT TO LATERAL LOADING. Dr. Jesús Gómez, P.E.
MICROPILES SUBJECT TO LATERAL LOADING Dr. Jesús Gómez, P.E. Micropile Design and Construction Seminar Las Vegas, NV April 3-4, 2008 Outline When are micropiles subject to lateral load? How do we analyze
More informationEXAMPLE 1 DESIGN OF CANTILEVERED WALL, GRANULAR SOIL
EXAMPLE DESIGN OF CANTILEVERED WALL, GRANULAR SOIL A sheet pile wall is required to support a 2 excavation. The soil is uniform as shown in the figure. To take into account the friction between the wall
More informationQuick fix for frost heave:
Quick fix for frost heave: HELICAL PILES Megan Milbradt Civil Engineer Basin Electric Power Shane Vasbinder Civil Engineer Basin Electric Power Concrete piers were 6 inches to 2 feet out of the ground.
More informationSECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
More informationSUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
More informationUnderpinning Systems 14.1 FOUNDATION REPAIR. Helical Piles
Helical Piles Howard A. Perko Copyright 0 2009 by John Wiley & Sons, Inc. All rights reserved. C h a p t e r 14 Underpinning Systems There has been tremendous growth in the use of helical piles for underpinning
More informationDIRT DWELLING. and your. www.pinfoundations.com. Pin Foundations Inc., 2008
DIRT and your DWELLING 2008 Pin Foundations Inc., 2008 If we accept that preserving soil in its native condition is necessary, then how do we build? Utilities? Roads? Foundations? Typical Strip, Transfer,
More informationCITY OF LOS ANGELES CALIFORNIA
BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI
More informationSTRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.
STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill
More informationEvaluation Report CCMC 13102-R Pieux Vissés Vistech / Postech Screw Piles
Evaluation Report CCMC 13102-R Pieux Vissés Vistech / Postech Screw Piles 1. Opinion 1of 6 MASTERFORMAT: 31 62 16.01 Evaluation issued: 2003-02-13 Re-evaluated: 2015-03-13 Re-evaluation due: 2018-02-13
More informationAnnual Kansas City Specialty Seminar 2014. Recent Advances in Design and Construction of Helical Foundations
Annual Kansas City Specialty Seminar 2014 Recent Advances in Design and Construction of Helical Foundations Helical Foundations History, Applications and Recent Research Dr. Samuel P. Clemence Syracuse
More informationc. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.
Design Manual Chapter 6 - Geotechnical 6B - Subsurface Exploration Program 6B-2 Testing A. General Information Several testing methods can be used to measure soil engineering properties. The advantages,
More informationDesign, Testing and Automated Monitoring of ACIP Piles in Residual Soils
Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils Stephen W. Lacz 1, M. ASCE, P.E. and Richard C. Wells 2, F. ASCE, P.E. 1 Senior Professional, Trigon Kleinfelder, Inc., 313 Gallimore
More informationCHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE
CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE 9.1 INTRODUCTION An important reason that composite piles have not gained wide acceptance in the civil engineering practice is the lack of a long
More informationCEEN 162 - Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests
PURPOSE: The parameters of the shear strength relationship provide a means of evaluating the load carrying capacity of soils, stability of slopes, and pile capacity. The direct shear test is one of the
More informationInstrumentations, Pile Group Load Testing, and Data Analysis Part II: Design & Analysis of Lateral Load Test. Murad Abu-Farsakh, Ph.D., P.E.
Instrumentations, Pile Group Load Testing, and Data Analysis Part II: Design & Analysis of Lateral Load Test Murad Abu-Farsakh, Ph.D., P.E. Louisiana Transportation Research Center Louisiana State University
More informationpower-installed foundations,
power-installed foundations, GUY ANCHORS and INSTALLing Equipment D uring the past 35 years, Chance expertise and resources have perfected power-installed foundations and guy anchors supporting many utility
More informationINTRODUCTION. Intro-1. Copyright 2003 Hubbell, Inc. Helical Screw Foundation System Design Manual for New Construction A.B.
INTRODUCTION Definition: Helical Screw Foundation The helical screw foundation can be devised into a deep foundation system to support or resist any load or application. Installed by lightweight mobile
More informationALLOWABLE LOADS ON A SINGLE PILE
C H A P T E R 5 ALLOWABLE LOADS ON A SINGLE PILE Section I. BASICS 5-1. Considerations. For safe, economical pile foundations in military construction, it is necessary to determine the allowable load capacity
More informationGEOTECHNICAL ENGINEERING FORMULAS. A handy reference for use in geotechnical analysis and design
GEOTECHNICAL ENGINEERING FORMULAS A handy reference for use in geotechnical analysis and design TABLE OF CONTENTS Page 1. SOIL CLASSIFICATION...3 1.1 USCS: Unified Soil Classification System...3 1.1.1
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationGUIDE TO MODEL SPECIFICATION CHANCE Civil Construction
GUIDE TO MODEL SPECIFICATION CHANCE Civil Construction HELICAL PILES F STRUCTURAL SUPPT TYPES OF SPECIFICATIONS The three types of specifications that are used for Helical Pile projects are: Open Specifications:
More informationFoundation Code compliance and Best Practices By Michael Coello
Foundation Code compliance and Best Practices By Michael Coello Background Graduated cum laude in 1992 with a Bachelor of Science degree in finance from University of Wisconsin - Parkside Started poured
More informationDesign and Construction of Auger Cast Piles
Design and Construction of Auger Cast Piles 101 th Annual Road School 2015 3/11/2015 Malek Smadi, Ph.D., P.E. Principal Engineer - GEOTILL - Fishers, IN msmadi@geotill.com - www.geotill.com CONTENTS 1.
More informationSPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)
Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks
More informationHigh Strain Dynamic Load Testing of Drilled Shafts
Supplemental Technical Specification for High Strain Dynamic Load Testing of Drilled Shafts SCDOT Designation: SC-M-712 (9/15) September 3, 2015 1.0 GENERAL This work shall consist of performing high-strain
More informationDESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,
DESIGN OF SLABS Dr. G. P. Chandradhara Professor of Civil Engineering S. J. College of Engineering Mysore 1. GENERAL A slab is a flat two dimensional planar structural element having thickness small compared
More informationSoils, Foundations & Moisture Control
Soils, Foundations & Moisture Control Soil The top loose layer mineral and/or organic material on the surface of the Earth that serves as a natural medium for the growth of plants and support for the foundations
More informationThe International Workshop on Micropiles, 2007
MICROPILE FOUNDATION REPAIR AND UNDERPINNING, ARTS AND SCIENCE MUSEUM, UNIVERSITY OF PUERTO RICO, MAYAGUEZ Presented at: International Society of Micropiles (ISM) The International Workshop on Micropiles,
More informationA Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.
A Solid Foundation Solution for Homeowners from Our products are made with 90% Recycled Material Down. Right. Solid. GREEN. Stop the damaging effects of foundation settling... Sinking foundations, cracked
More informationSports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049
Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal
More informationSubmittal Information
Wedge SPECIFIED FOR ANCHORAGE INTO CONCRETE Wedge anchs feature a stainless steel expansion clip, threaded stud body, nut and washer. Anch bodies are made of plated carbon steel, hot-dipped galvanized
More informationSpecification Guidelines: Allan Block Modular Retaining Wall Systems
Specification Guidelines: Allan Block Modular Retaining Wall Systems The following specifications provide Allan Block Corporation's typical requirements and recommendations. At the engineer of record's
More informationITEM #0702770 OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT
ITEM #0702770 OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT Description: This work shall consist of furnishing all materials, equipment and labor necessary for conducting an Osterberg Cell (O-Cell) Load
More informationHELICAL SCREW PILES (HSP) CAPACITY FOR AXIAL CYCLIC LOADINGS IN COHESIVE SOILS
4 th International Conference on Earthquake Geotechnical Engineering June 25-28, 27 Paper No. 1567 HELICAL SCREW PILES (HSP) CAPACITY FOR AXIAL CYCLIC LOADINGS IN COHESIVE SOILS M. Hesham EL NAGGAR 1,
More information1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
More informationType of Force 1 Axial (tension / compression) Shear. 3 Bending 4 Torsion 5 Images 6 Symbol (+ -)
Cause: external force P Force vs. Stress Effect: internal stress f 05 Force vs. Stress Copyright G G Schierle, 2001-05 press Esc to end, for next, for previous slide 1 Type of Force 1 Axial (tension /
More informationGreen Thread Product Data
Green Thread Product Data Applications Dilute Acids Caustics Produced Water Industrial Waste Hot Water Condensate Return Materials and Construction All pipe manufactured by filament winding process using
More informationPro-Lift Steel Pile Foundation Repair
Pro-Lift Steel Pile Foundation Repair Pro-Lift Steel Pile Foundation Repair System Pro-lift steel piles are designed for the stresses of Texas soils. They can have multiple steel walls, depending on the
More informationOptimised Design for Soil Nailed Walls 1
Optimised Design for Soil Nailed Walls 1 J A R Ortigao 1 and E M Palmeira 2 1 Federal University of Rio de Janeiro, Rio de Janeiro, Brazil 2 University of Brasília, Brasília, Brazil INTRODUCTION The first
More informationDESIGN OF PILES AND PILE GROUPS CONSIDERING CAPACITY, SETTLEMENT, AND NEGATIVE SKIN FRICTION
DESIGN OF PILES AND PILE GROUPS CONSIDERING CAPACITY, SETTLEMENT, AND NEGATIVE SKIN FRICTION Introduction Bengt H. Fellenius, Dr.Tech., P.Eng. Background Notes for Demo Example for UniPile at www.unisoftltd.com
More informationUSE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch
USE OF MICROPILES IN TEXAS BRIDGES by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch DEFINITION OF A MICROPILE A micropile is a small diameter (typically less than 12 in.), drilled and
More informationDESIGNING STRUCTURES IN EXPANSIVE CLAY
DESIGNING STRUCTURES IN EXPANSIVE CLAY A GUIDE FOR A RCHITECTS AND E NGINEERS Table of Contents 1. Introduction Page 1 2. Common Foundation Systems Page 2 3. Drilled Piers Page 3 a. Skin Friction Piers
More informationTZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE
SECTION 2.2 PAGE 1 / 9 l DESCRIPTION UCAN TZ torque controlled mechanical expansion wedge anchors have a Category 1 classification. They are used to resist static, wind and seismic tension and shear loads
More informationSECTION 02845 GUARDRAILS
SECTION 02845 GUARDRAILS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals necessary and repair, replace or install all types of guardrails as specified herein
More informationStrengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps
Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning May 7th 2013: Dominique Deschamps Scope of the paper Presentation of the project Cause of cracks
More informationEVALUATING INSTALLATION DISTURBANCE OF HELICAL ANCHORS IN CLAY FROM FIELD VANE TESTS
EVALUATING INSTALLATION DISTURBANCE OF HELICAL ANCHORS IN CLAY FROM FIELD VANE TESTS Alan J. Lutenegger, John Erikson and Nicholas Williams, Department of Civil & Environmental Engineering, University
More informationCONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST
CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST 1 Permeability is a measure of the ease in which water can flow through a soil volume. It is one of the most important geotechnical parameters. However,
More informationNational Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination
Structural Effective Beginning with the April 2011 The structural engineering exam is a breadth and exam examination offered in two components on successive days. The 8-hour Vertical Forces (Gravity/Other)
More informationKWANG SING ENGINEERING PTE LTD
KWANG SING ENGINEERING PTE LTD 1. INTRODUCTION This report represents the soil investigation works at Aljunied Road / Geylang East Central. The objective of the soil investigation is to obtain soil parameters
More informationDIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA
DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA DIRECT SHEAR TEST OBJEVTIVES To determine the shear strength parameters for a
More informationHighly flexible couplings
Construction and operation 8.03.00 Instructions for installation 8.03.00 Types of stress 8.04.00 Diagrams for static deformation of the coupling ring 8.05.00 Coupling size 8.07.00 Examples of combinations
More informationReport on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars
Report on Wind Resistance of Signs supported by Glass Fiber Reinforced Concrete (GFRC) Pillars Prepared for US Sign and Fabrication Corporation January, 2006 SUMMARY This study found the attachment of
More informationHUS-H Screw Anchor. Technical data. Seismic design data. HUS-H Carbon steel screw anchor. HUS-H diameter 8, 10, 14. Seismic design data
Technical data HUS-H Carbon steel screw anchor HUS-H diameter 8, 10, 14 10 / 011 Version 011-10 1 HUS-H screw anchor seismic design data Anchor version Carbon steel screw Benefits - Quick and easy setting
More informationDesigned and Engineered to Perform
History EARTH CONTACT PRODUCTS, L.L.C., is a family owned company, based in Olathe, Kansas. This company was built upon Don May s U.S. Patented fourth-generation Steel Piering System that has led to the
More informationHelical Foundation Systems
Helical Foundation Systems The leading edge in helical foundations MacLean-Dixie The Leading Edge MacLean-Dixie s helical foundation systems offer the leading edge. If you re still considering concrete
More informationHow To Design A Foundation
The Islamic university - Gaza Faculty of Engineering Civil Engineering Department CHAPTER (2) SITE INVESTIGATION Instructor : Dr. Jehad Hamad Definition The process of determining the layers of natural
More informationINSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!
In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible
More informationB.TECH. (AEROSPACE ENGINEERING) PROGRAMME (BTAE) Term-End Examination December, 2011 BAS-010 : MACHINE DESIGN
No. of Printed Pages : 7 BAS-01.0 B.TECH. (AEROSPACE ENGINEERING) PROGRAMME (BTAE) CV CA CV C:) O Term-End Examination December, 2011 BAS-010 : MACHINE DESIGN Time : 3 hours Maximum Marks : 70 Note : (1)
More informationTrench Rescue by Buddy Martinette
Trench Rescue by Buddy Martinette SOIL TYPE AND TESTING It is imperative that rescue personnel understand soil types and testing procedures if the want to be competent at trench rescue operations. Determining
More informationGUIDELINE FOR HAND HELD SHEAR VANE TEST
GUIDELINE FOR HAND HELD SHEAR VANE TEST NZ GEOTECHNICAL SOCIETY INC August 2001 CONTENTS Page 1.0 Introduction 2 2.0 Background 2 3.0 Recommended Practice 3 4.0 Undrained Shear Strength 3 5.0 Particular
More informationSoil Screw Design Manual Edition 2
Soil Screw Design Manual Edition 2 Page TOC-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2015 CONTENTS CONTENTS TABLE of CONTENTS INTRODUCTION and APPLICATIONS Section 1 PURPOSE AND SCOPE...
More information