Introducing the Revolutionary New Microwave Plasma-Atomic Emission Spectrometer - It Runs on Air!
|
|
- Felix McCormick
- 7 years ago
- Views:
Transcription
1 Introducing the Revolutionary New Microwave Plasma-Atomic Emission Spectrometer - It Runs on Air! Evrim Kilicgedik Product Specialist, Atomic Spectroscopy Agilent Technologies Page 1
2 2011 Start of the Atomic Spectroscopy Revolution! Agilent has launched a revolutionary new Atomic Spectroscopy instrument This instrument doesn t just redefine a category it creates a new one! No other instrument like it exists! This technique delivers: Improved performance compared with conventional flame AA Improved ease of use Lower running costs Allows unattended multi-element analysis Improved laboratory safety If you re a flame AA user, be prepared to save thousands of dollars per year Does that sound appealing??? Page 2
3 Common Challenges facing Laboratories doing Elemental Analysis Today Increased need for multi-element determination over a wide dynamic range Desire to reduce the overall cost of analysis due to rising costs (instrument supplies and consumables power, labor, etc) Difficulty in sourcing some gases especially in remote areas and emerging geographies Availability of suitably trained personnel to develop methods, perform sample measurement and interpret results Some laboratories under pressure to improve safety by removing flammable gases Page 3
4 NEW Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer (MP-AES) New technique for elemental determination using atomic emission Microwave excited plasma source Nitrogen based plasma - runs on air (using a N 2 generator) oimproved performance compared with flame AA Higher sample throughput with fast sequential measurement More than 2x faster than conventional flame AA Superior detection limits and improved dynamic range oeasy to use New generation software featuring automated optimization and software applets that load a preset method One piece torch with easy torch removal and replacement no alignment oreduced operating costs Runs on air eliminates need for Acetylene, Nitrous Oxide, Argon, etc. Eliminates need for source / hollow cathode lamps Simple installation no chiller, 10 A supply oimproved Safety Eliminates need for flammable gases and cylinder handling Safe, reliable unattended multi-element overnight operation Page 4
5 Microwave Plasma Emission Overview Ground State Excited State Emission Monochromator & Detector Quantitation Microwave excited Plasma Sample Page 5
6 How Does MP-AES Work? Agilent s patented microwave waveguide technology Using nitrogen as the plasma gas (a diatomic gas) gives a robust plasma with a conventional torch. Nitrogen can be supplied either via bottled gas or nitrogen generator Magnetic excitation gives a toroidal plasma and an effective central zone for sample injection The microwave magnetically excited nitrogen plasma Provides a robust, high temperature source in conventional torches (approx K) A cooler central channel suitable for sample atomization Creates high intensity atomization emission lines Page 6
7 Performance Comparison Typical Detection Limits DL s in ppb, clean water samples Element Flame AA MP-AES K Ca Mg Na Au Pt Pd Ag Rh Element Flame AA MP-AES As* Cd Cr Mn Pb Sb Se* Zn * 30 second integration time used for As and Se 3 sigma DLs using a 10 second integration time with dewar nitrogen Page 7
8 Au Extended Calibration Range MP - Normal AA range MP - Extended Range Page 8
9 Page 9 Simple Torch Installation No Alignment
10 New Generation MP Expert Software Windows 7, worksheet based software Fresh, clean look Provides capability for applet style operation using preset methods, or access to full capabilities Innovative and simple to use background correction Automated optimization tools Page 10
11 New Generation MP Expert Software Retains familiar worksheet based approach Spectra Results matrix Calibration Replicate data Page 11
12 Typical Instrument Operating Parameters Instrument Parameter Setting Nebulizer pressure Pump speed Pump tubing Integration time No. of replicates 3 Sample uptake delay Stabilization time Fast Pump during Uptake Viewing position Sampling mode Background correction kpa (optimize per element) 15 rpm White-white (sample) Blue-blue (waste) 3-5 sec for most samples; sec at DL levels 15 sec (typical) 10 sec On (80 rpm) -10 to +10 (optimize per element) Manual or Auto sampling Auto or FLIC Page 12
13 Optical Diagram Detector Pre-optics Monochromator Cassette style Torch Page 14
14 Accessory Options for the 4100 MP-AES Automate and simplify analysis with the SPS3 autosampler (required for unattended overnight operation) For organic applications, use the EGCM to bleed air into the plasma minimizing C build-up and reducing background also requires the OneNeb inert nebulizer (included with the Organics kit) For low ppb level detection of As, Se or Hg, use the Multimode Sample Introduction System (MSIS) also requires the 5 channel peristaltic pump option Page 16
15 Technique Comparison: MP-AES and Flame AA Page 17
16 Reduced Cost of Ownership Cost savings based on reductions in gas expenses ONLY!. Assumes measuring 9 elements (4 nitrous-oxide elements) in batches of 100 samples, 3 days/week using the N 2 generator. For a detailed cost comparison, consult your local Agilent representative Page 18
17 Newmont's Carlin Lab AA Consumable Costs vs MP-AES* * Acknowledgement John Borland, Newmont Mining Corporation Page 19
18 Key Customer Benefits Higher Performance Ideal flame AA alternative Handles major, minor & most trace levels Matrix handling to match flame AA Lower Cost of Ownership Runs on air Multi-element unattended operation Moderate sample throughput Faster Measurement & Easy Operation Fast sequential measurement Simultaneous background correction New generation software Plug & Play torch Safer Laboratory Operation No flammable gases Unattended multielement operation Page 20
19 Page 21 Market Application Examples
20 Geochemical, Metals and Mining Applications Page 26
21 Gold and Precious Metals by Fire Assay Au, Pt and Pd extracted into a silver sphere Page 27
22 Traditional Off-Peak Correction for Ag in Digest Limitations with Off-Peak Correction Correction points must be set manually Susceptible to spectral interferences Is this the best correction point for this matrix? Page 28
23 Better Alternative - Use Auto Correction Auto background correction uses the spectrum around the peak of interest to create: 1. Models of the background (the blank) and the analyte (the standards) these are created during calibration 2. For every sample the amount of blank model and the amount of analyte model in the spectrum is calculated 3. Once the amount of analyte is known, the corrected concentration can be determined Page 29
24 Auto Correction for Ag in Digest Accurate model of the sloping background from the partial peak overlap Blank Spectrum Standard Spectrum Page 30
25 Auto Correction Improves Detection Limits Element Wavelength (nm) DL with Auto Correction (ppb) DL with Off-Peak Correction (ppb) Ag Zn Mn Mn Cu K As And it s easier to use! No method development No correction points to select Page 31
26 Accuracy Gold in Custom CRMs* CRM Certified value (mg/l) MP-AES result (mg/l) * These custom CRMs were professionally prepared from solid ore samples and certified through a round robin test process Page 32
27 Accuracy Platinum & Palladium in Custom CRMs Platinum CRM Certified value (mg/l) MP-AES result (mg/l) Palladium CRM Certified value (mg/l) MP-AES result (mg/l) Page 33
28 Chemical and Petrochemical Applications Page 34
29 Organics - External Gas Control Module (EGCM) 1. Prevents carbon build up on the injector when running organics 2. Reduces the background emissions from the plasma 3. A controlled flow of air is bled into the Auxiliary gas flow through the torch Page 35
30 For Challenging Applications OneNeb Nebulizer Robust PFA and PEEK construction Inert - resistant to strong acids such as HF Resistant to breakage Molded plastic design provides improved nebulizer to nebulizer reproducibility Constant diameter narrow bore tubing through to nebulizer tip Ideal for high solids/particulates Improved tolerance to high TDS samples Narrow aerosol size distribution provides improved precision Handles a wide flow range from 0.1 to 2 ml/min. No sensitivity loss at low flow rates Page 38
31 Principle of Operation Inert OneNeb Nebulizer Tip geometry dimensioned to allow carrier gas to mix with the sample Turbulent mixing of liquid and gas occurs Produces aerosol with a narrow size distribution range Droplets mixed into gas flow No area of low pressure Unique Flow Blurring action increases nebulization efficiency Greater efficiency than conventional concentric nebulizer Improved sensitivity Inert OneNeb nebulizer Conventional concentric nebulizer Page 39
32 Instrument Parameters Parameter Setting Nebulizer Inert OneNeb Spray chamber Double-pass glass cyclonic Sample tubing Orange/green solvent resistant Waste tubing Blue/blue solvent resistant Read Time 3 s Replicates 3 Stabilization time 15 s Rinse time 45 s Fast Pump (80 rpm) On Background correction Auto Pump speed 5 rpm Page 40
33 Standard and Sample Preparation Wear metals and contaminants 1:10 dilution with Shellsol Additives 1:100 dilution with Shellsol Standards Prepared from 500 ppm S21 (Conostan) All matrix matched with blank oil for constant viscosity Page 41
34 Measured Results for SRM 1085b Wear Metals Great recoveries for all key elements Page 42
35 Measured Recoveries on 10 ppm Spike of Gear Oil Great recoveries for all key elements Page 43
36 Measured Results for Additive Elements Measured Results vs Certified Values Element Measured (mg/kg) Certified (mg/kg) Recovery % P ± ± Zn ± ± Mg ± ± Ca ± Ba ± ± Measured Recoveries on 10 ppm Spike of Gear Oil Element Mixed Gear (ppm) Spike (ppm) Recovery % P Zn Mg Ca Ba Page 44
37 Organics Long Term Stability 10 ppm S21. All lines show precision <1% RSD. Page 45
38 Food and Agricultural Applications Page 46
39 Measured Results for CRM Food Samples NIES No. 10c Rice Flour High Purity Stds CRM Wheat Flour * Reference values only Page 47
40 Wide Dynamic Range Page 48
41 Soil Analysis - Background and Interference Correction Used Analyte Wavelength (nm) Background Correction Al Auto As FLIC Cr Auto Cu Auto Fe Auto Mn Auto Ni Auto Pb Auto Zn Auto Page 49
42 Fast Linear Interference Correction (FLIC) FLIC uses models of the blank, standard and potential interferent elements to correct for spectral interferences Page 50
43 FLIC Performance Example Fe Interference on As As concentration in the presence of 1,000 ppm Fe is <IDL when using FLIC Using Auto Using FLIC Page 51
44 Measured Results for NIST SRM 2711 Montana Soil Analyte MP-AES Results NIST Reference Average (mg/kg) Range (mg/kg) Al ± As 90 ± Cr 21 ± Cu 90 ± Fe ± Mn 600 ± Ni 17 ± Pb 1400 ± Zn 300 ± Page 52
45 Improving Detection Limits for As, Se and Hg with MSIS Analyte Conventional Nebulization µg/l MSIS in Simultaneous Mode µg/l As Se Hg Page 53
46 Comments from Early Adaptor Seed Sites Newmont Mining Corporation, USA With the MP-AES instrument Agilent seems to have hit a homerun for both gold analysis and base metal analysis. It provides superior detection limits and vastly expanded calibration range this enables quick easy analysis at trace levels as well as eliminates the need for time consuming dilutions of higher grade samples. All of this at an affordable price of well below that of ICP and only slightly higher than top of the line AA units. Bobby Joe Reichel Newmont Mining Corporation Sachsenforst, Germany The results for our aqua regia soil extract samples are convincing, and those results are in very good agreement with the round robin, which was performed Europe wide on those samples. Frank Symossek Sachsenforst CERA Laboratory, India We are using MP-AES instrument for last couple of months, and we found instrument is best to detect trace metals compare to AAS. In AAS sensitivity for B and P is very poor and fuel cost is very high, whereas using the MP-AES, sensitivity is very, very good and fuel cost is very low. In AAS, with elements like Al, Ca, Mo,Ti, V, Si etc, it consumes high quantities of Acetylene and Nitrous Oxide gas, and is very tricky - whereas using the MP-AES, it is very easy to detect. There is also no need to change Hollow Cathode Lamps which is time consuming and costly. S.S. Mhatre CERA Laboratory Page 54
47 Agilent 4100 MP-AES Runs on air the most significant advance in atomic spectroscopy o o o Lowest running cost of any atomic spectroscopy technique due to capability to run on air ideal for remote and at site operation Improved safety capability to run on air means no flammable gases and no manual handling of cylinders Easy-to-use software with MP applets and plug and play torch which simplify operation and maximize uptime osuperior performance to flame AA, with capability to run unattended overnight Page 55
48 Questions? Agilent MP-AES The Market Leaders in Atomic Spectroscopy Page 56
Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber
Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber Application note Energy & chemicals, petrochemicals Authors Elizabeth
More informationDetermination of Metals in a 3% Sodium Chloride (NaCl) Matrix by Axially-Viewed ICP-OES
Determination of Metals in a 3% Sodium Chloride (NaCl) Matrix by Axially-Viewed ICP-OES Application Note Inductively Coupled Plasma-Optical Emission Spectrometers Author Deen Johnson Introduction The development
More informationUniversal Data Acquisition (UDA)
Universal Data Acquisition (UDA) I C P - O P T I C A L E M I S S I O N P R O D U C T N O T E Introduction Historically, Inductively Coupled Plasma (ICP) spectroscopy has been used for multiple analyte
More informationElemental Analyses by ICP-AES
Elemental Analyses by ICP-AES Henry Gong, Senior Analytical Chemist September 10, 2008 ICP-AES inductively coupled plasma atomic emission spectrophotometry Electrons of an atom absorb energy and jump to
More informationGraphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.
Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY I. BACKGROUND (VERSION 1.0) Atomic absorption spectroscopy (AAS) is a widely used
More informationUniversity of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)
University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence) For this laboratory exercise, you will explore a variety of spectroscopic methods used in an analytical
More informationStandard Operation Procedure. Elemental Analysis of Solution samples with Inductively Coupled Plasma Mass Spectrometry
Standard Operation Procedure Elemental Analysis of Solution samples with Inductively Coupled Plasma Mass Spectrometry Soil & Plant Analysis Laboratory University of Wisconsin Madison http://uwlab.soils.wisc.edu
More informationVALIDATION REPORT. Investigation of the major interferences for proposed Horizontal ICP AES method. ECN protocol
Page 1 van 36 pages VALIDATION REPORT Investigation of the major interferences for proposed Horizontal ICP AES method Identification code Validation in accordance with Reference method Scope Reference
More informationNANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT
NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT AND ANALYSIS SEPTEMBER 2012, V 1.1 4878 RONSON CT STE K SAN DIEGO, CA 92111 858-565 - 4227 NANOCOMPOSIX.COM Note to the Reader: We at nanocomposix have published
More informationHow To Use The Nexion 300
APPLICATION NOTE ICP - Mass Spectrometry Authors Ewa Pruszkowski, Ph.D. Senior ICP-MS Application Scientist Cynthia P. Bosnak Senior Product Specialist PerkinElmer, Inc. Shelton, CT USA The Analysis of
More informationaurora M90 Innovation with Integrity A new era in ICP-MS ICP-MS
aurora M90 A new era in ICP-MS Innovation with Integrity ICP-MS Your Partner in ICP-MS Solutions Bruker continues to find new and novel ways to meet your changing needs. As a leader in elemental analysis
More informationApplication of ICP-MS as a Tool for Environmental Monitoring. Bill Spence Environmental Market Specialist
Application of ICP-MS as a Tool for Environmental Monitoring Bill Spence Environmental Market Specialist Introduction Knowledge of the concentration of metallic species in the environment has been important
More informationSimplicity. Reliability. Performance
Simplicity Reliability Performance ICP Without Compromise At Teledyne Leeman Labs atomic spectroscopy is our business, our only business. We are deeply committed to providing you with technically superior
More informationUNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850
UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850 Test Method: CPSC-CH-E1001-08.2 Standard Operating Procedure
More informationAnalysis of Chlorine, Bromine and Iodine in Water using ICP-AES
ICP OPTICAL ATOMIC EMISSION SPECTROSCOPY Analysis of Chlorine, Bromine and Iodine in Water using ICP-AES HORIBA Scientific Longjumeau, France Keywords: metallurgy, non-ferrous, halogens 1 Introduction
More informationAgilent 720/730 Series ICP-OES
Agilent 720/730 Series ICP-OES Flexible. Productive. Robust. Specifications Introduction Agilent 720/730 Series ICP-OES spectrometers are manufactured according to a quality management system certified
More informationFlow Injection Analysis
Flow Injection Analysis Almost all reagent based assays can be downscaled and automated by Flow Injection Analysis. FIA was first described in a patent filed in Denmark by Ruzicka and Hansen in 1974. Since
More informationHeavy Metal Analysis for the Toy Industry by Inductively Coupled Plasma Optical Emission Spectroscopy
Heavy Metal Analysis for the Toy Industry by Inductively Coupled Plasma Optical Emission Spectroscopy In support of the toy industry, many laboratories are being called upon to analyze a wide variety of
More informationElemental Scientific. Stability. Elemental Scientific
Elemental Scientific prepfast ICP-MS: USP Oral Drugs by Dilution Automated Inline Calibration and Sample Dilution Authors: Kyle Uhlmeyer and Paul Field (field@icpms.com) Brief The prepfast inline
More informationOLIVÉR BÁNHIDI 1. Introduction
Materials Science and Engineering, Volume 39, No. 1 (2014), pp. 5 13. DETERMINATION OF THE ANTIMONY- AND STRONTIUM- CONTENT OF ALUMINIUM ALLOYS BY INDUCTIVELY COUPLED PLASMA ATOM EMISSION SPECTROMETRY
More informationModern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and
Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and disadvantages Atomic spectroscopy Atomic spectroscopy
More informationPortable X-ray fluorescence Spectroscopy. Michael A. Wilson Research Soil Scientist USDA-NRCS National Soil Survey Center Lincoln, NE
Portable X-ray fluorescence Spectroscopy Michael A. Wilson Research Soil Scientist USDA-NRCS National Soil Survey Center Lincoln, NE OBJECTIVES Background of the method Features of the instrument Applications
More informationATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS
1 ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS Buck Scientific Atomic Absorption Spectrophotometer, Model 200 Atomic absorption spectroscopy (AAS) has for many years
More informationElemental analyzer multi EA 5000
Elemental analyzer multi EA 5000 Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena/Germany www.analytik-jena.com info@analytik-jena.com 1/6 multi EA 5000 The multi EA 5000 is a powerful elemental analyzer
More informationlimit to percentage levels, a limited working range translates
Figure 1. The AutoPrep 50 Automatic Dilution System. Figure 2. Schematic diagram of the AutoPrep 50. Flame atomic absorption spectroscopy (flame AA) is still the most frequently used instrumental technique
More informationImage Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems
Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES FIMS 100 and 400 Flow Injection Mercury Systems Delivering the Performance You Need The determination and monitoring of sub-ppb concentrations
More informationGold Refining and Coin Manufacturing at the Royal Canadian Mint
INTERNET Sub title will go here The Application of XRF to Gold Refining and Coin Manufacturing at the Royal Canadian Mint Michael W. Hinds, Ph.D. The Business of the Mint Circulation Coins (Canada & Other
More informationFMA-80 Fluorescence Mercury Analyzer
FMA-8 Fluorescence Mercury Analyzer www.milestonesrl.com MILESTONE H E L P I N G C H E M I S T S The new Milestone FMA-8 The mercury problem A wide range of mercury analyzers Milestone offers a wide range
More information3 - Atomic Absorption Spectroscopy
3 - Atomic Absorption Spectroscopy Introduction Atomic-absorption (AA) spectroscopy uses the absorption of light to measure the concentration of gas-phase atoms. Since samples are usually liquids or solids,
More informationMILESTONE CLEAN CHEMISTRY LINE DUOPUR TRACECLEAN ULTRA-TRACE INSERTS. A Breakthrough in Reduction and Control of the Analytical Blank MILESTONE
MILESTONE CLEAN CHEMISTRY LINE A Breakthrough in Reduction and Control of the Analytical Blank DUOPUR TRACECLEAN ULTRA-TRACE INSERTS MILESTONE MILESTONE CLEAN CHEMISTRY LINE An innovative and complete
More informationEDXRF of Used Automotive Catalytic Converters
EDXRF of Used Automotive Catalytic Converters Energy Dispersive X-Ray Fluorescence (EDXRF) is a very powerful technique for measuring the concentration of elements in a sample. It is fast, nondestructive,
More informationHow To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer
What is ICP-MS? and more importantly, what can it do? Inductively Coupled Plasma Mass Spectrometry or ICP-MS is an analytical technique used for elemental determinations. The technique was commercially
More informationDMA-80 Direct Mercury Analyzer
DMA-80 Direct Mercury Analyzer Milestone Srl Milestone Srl 1 Introduction Mercury in the atmosphere can be from manmade sources (coal-fired power plants, municipal incinerators, industrial boilers) or
More informationLead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb
Document: AND Lead 100 7 2013 Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb July, 2013 Edition 1 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table of Contents
More informationX-RAY FLUORESCENCE SPECTROSCOPY IN PLASTICS RECYCLING
X-RAY FLUORESCENCE SPECTROSCOPY IN PLASTICS RECYCLING Brian L. Riise and Michael B. Biddle MBA Polymers, Inc., Richmond, CA, USA Michael M. Fisher American Plastics Council, Arlington, VA, USA X-Ray Fluorescence
More informationDimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856
Nickel DOC316.53.01065 Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows
More informationAPPLICATION OF ICP-MS TECHNOLOGY FOR TRACE METALS ANALYSIS
MR. TELLIARD: Our next speaker is Paula Hogg. Paula is currently a lab manager at Hampton Roads Sanitation District s Central Environmental Laboratory. We would like to also thank Hampton Roads for sending
More informationSample Analysis Design Isotope Dilution
Isotope Dilution Most accurate and precise calibration method available Requires analyte with two stable isotopes Monoisotopic elements cannot be determined via isotope dilution Spike natural sample with
More informationA fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS
A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS Kent W. Warnken, Thermo Fisher Scientific, USA Patrick Messina, Quest Diagnostics,
More informationUltima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use
Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use Designed to Handle the Most Challenging Applications HORIBA Scientific develops and manufactures high performance ICP-OES spectrometers
More informationSUS. Company Profile. Ulrich Nell, Feldstr.23, D - 46149 Oberhausen, Tel. 0049(0)208/658535 Fax 0049(0)208/658536
SUS Ulrich Nell, Feldstr.23, D - 46149 Oberhausen, Tel. 0049(0208/658535 Fax 0049(0208/658536 Company Profile SUS was founded in 1986 in Oberhausen in the Ruhr area (close to Düsseldorf, in order to meet
More informationMILESTONE H E L P I N G C H E M I S T S
MILESTONE H E L P I N G C H E M I S T S 8 good reasons to choose the Milestone DMA-80 1. No sample preparation The DMA-80 does not require any sample preparation or other wet chemistry prior the analysis.
More informationHow To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
More informationPowerful Analytics based on Modern Spectrometers
Powerful Analytics based on Modern Spectrometers Gerhard Schlemmer Analytik Jena AG, Konrad- Zuse- Str. 1, 07745 Jena g.schlemmer@analytik-jena.de 1 1 Powerful Analytics based on Modern Spectrometers Optimizing
More informationHS 1003 Part 2 HS 1003 Heavy Metals Test
HS 1003 Heavy Metals Test 1. Purpose This test method is used to analyse the heavy metal content in an aliquot portion of stabilised hot acetic acid extract by Atomic Absorption Spectroscopy (AAS). Note:
More informationStandard Operation Procedure. Elemental Analysis of Solution Samples with Inductively Coupled Plasma Optical Emission Spectrometry
Standard Operation Procedure Elemental Analysis of Solution Samples with Inductively Coupled Plasma Optical Emission Spectrometry Soil & Plant Analysis Laboratory University of Wisconsin Madison http://uwlab.soils.wisc.edu
More informationSCP SCIENCE www.scpscience.com. Certified Reference Materials. Materials
Certified Reference 47 EnviroMAT and AgroMAT Certifi ed Reference (CRMs) are designed to complement existing Performance Evaluation Programs in environmental and agricultural analysis. EnviroMAT CRMs allow
More informationLaboratory Procedure Manual
Laboratory Procedure Manual Analyte: Matrix: Method: Method No.: Lead Dust Wipes Modification of the Automated AAII-25 Colorimetric method Nitric and Hydrochloric Acid Digestion followed by Atomic Absorption
More informationAppendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
More informationShort introduction into. Analytical Chemistry. by Prof. Dr. Manfred Sietz and Dr. Andreas Sonnenberg (PowerPoint slides)
Short introduction into Analytical Chemistry by Prof. Dr. Manfred Sietz and Dr. Andreas Sonnenberg (PowerPoint slides) What is Analytical Chemistry? study of methods for determining the composition of
More informationThermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data
Low cost ICP-OES analysis high quality data The NEW Thermo Scientific icap 7000 Series ICP-OES provides low cost multi-element analysis for measuring trace elements in a diverse sample range. The instrument
More informationDMA-1 Direct Mercury Analyzer
DMA-1 Direct Mercury Analyzer www.milestonesrl.com MILESTONE H E L P I N G C H E M I S T S 8 good reasons to choose the milestone DmA-1 1. no sample preparation 2. ease of use 3. lowest cost of analysis
More informationAutomation of Solid Phase Extraction and Column Chromatographic Cleanup
Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for
More informationORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
More informationRegional Environmental Protection Agency- Veneto Region LABORATORY REGIONAL DEPARTMENT
Twinning Contract BG 06 IB EN 01 Ministry of Environment & Water ICP-MS methods for metals: in-house validation and extension of field of application of methods from inland waters to transitional and sea-water.
More informationMETHOD 6010B INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROMETRY
METHOD 6010B INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROMETRY 1.0 SCOPE AND APPLICATION 1.1 Inductively coupled plasma-atomic emission spectrometry (ICP-AES) determines trace elements, including
More informationTransformer Oil Gas Analysis
Get on the Analyzer FAST TRACK Transformer Oil Gas Analysis Helping customers protect the environment! 1 Why Analyzers Value to Customers Alleviates Resource Pressure Facilitates Configuration Use Advanced
More informationCoating Thickness and Composition Analysis by Micro-EDXRF
Application Note: XRF Coating Thickness and Composition Analysis by Micro-EDXRF www.edax.com Coating Thickness and Composition Analysis by Micro-EDXRF Introduction: The use of coatings in the modern manufacturing
More informationAnalyses on copper samples from Micans
PDF rendering: DokumentID 1473479, Version 1., Status Godkänt, Sekretessklass Öppen Analyses on copper samples from Micans P. Berastegui, M. Hahlin, M. Ottosson, M. Korvela, Y. Andersson, R. Berger and
More informationChemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample
More informationNUTC R304. Use of Absorption Mechanisms to Decrease Heavy Metal Mobility
Use of Absorption Mechanisms to Decrease Heavy Metal Mobility by Jianmin Wang Honglan Shi Joe G. Burken NUTC R304 A National University Transportation Center at Missouri University of Science and Technology
More informationAccurate Determination of Lead in Different Dairy Products by Graphite Furnace Atomic Absorption Spectrometry
application Note Atomic Absorption Authors Jijun Yao Renkang Yang Jianmin Chen PerkinElmer, Inc. Shelton, CT 06484 USA Accurate Determination of Lead in Different Dairy Products by Graphite Furnace Atomic
More informationThe photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
More informationMODULE 2B INDUSTRIAL HYGIENE LABORATORY ACCREDITATION PROGRAM (IHLAP) ADDITIONAL REQUIREMENTS
2B.1 SCOPE MODULE 2B INDUSTRIAL HYGIENE LABORATORY ACCREDITATION PROGRAM (IHLAP) ADDITIONAL REQUIREMENTS The AIHA - Laboratory Accreditation Programs (AIHA-LAP), LLC s Industrial Hygiene Laboratory Accreditation
More informationSample Analysis Design Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors:
Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors: 1. potential matrix effects 2. number of samples 3. consistency of matrix across samples Step 2 Calibration/Standard
More informationPOLYDIMETHYLSILOXANE
POLYDIMETHYLSILOXANE Prepared at the 37th JECFA (1990), published in FNP 52 (1992) superseding specifications prepared at the 29th JECFA (1985), published in FNP 34 (1986). Metals and arsenic specifications
More informationHPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies
HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies Application Note Small Molecule Pharmaceuticals Authors Jignesh Shah, Tiantian Li, and Anil Sharma Agilent Technologies,
More informationFundamentals of modern UV-visible spectroscopy. Presentation Materials
Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms
More informationAPI 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined
API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation
More informationDetermination of elements by ICP-AES and ICP-MS
September 2003 HORIZONTAL - 19 Determination of elements by ICP-AES and ICP-MS Henk J van de Wiel National Institute of Public Health and the Environment (RIVM) Bilthoven, The Netherlands 1 HORIZONTAL
More informationAgilent Cary 60 UV-Vis
Agilent Cary 60 UV-Vis Efficient. Accurate. Flexible. Specifications Introduction The Agilent Cary 60 UV-Vis spectrophotometer is efficient, accurate and flexible, and is designed to meet both current
More informationLC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,
More informationEnhanced Organic Precursor Removals Using Aged Filter Media Page 1. Enhanced Organic Precursor Removals Using Aged Filter Media
Enhanced Organic Precursor Removals Using Aged Media Page 1 Enhanced Organic Precursor Removals Using Aged Media O b j e c t i v e s The main goals of this project was to evaluate the dissolved organic
More informationCertificate of Analysis
The Japan Society for Analytical Chemistry Certificate of Analysis Certified Reference Material JSAC 0602-3 Plastics (tip form) for Chemical Analysis of Hazardous Metals This certified reference material
More informationA Potentiometric Analysis of Fluoride Ion in Toothpaste
CHEM 311L Quantitative Analysis Laboratory Revision 2.0 A Potentiometric Analysis of Fluoride Ion in Toothpaste In this laboratory exercise, we will analyze a toothpaste sample for its Fluoride Ion (F
More informationICP-OES, ICP-MS and AAS Techniques Compared
ICP-OES, ICP-MS and AAS Techniques Compared Geoff Tyler Jobin Yvon S.A.S, Horiba Group Longjumeau, France Keywords: atomic spectroscopy, detection limit, linear dynamic range, interferences, precision,
More informationAdvanced Solutions for Gas Monitoring
Continuous Emissions Monitoring Stack Testing Process Monitoring Quality Control Engine Exhaust Gas Monitoring Workplace Air Quality Monitoring Combustion Research Emergency Rescue Services Advanced Solutions
More informationSCION SQ Series GC-MS
SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative
More informationIon Selective Electrodes
Ion Selective Electrodes OAKTON has a large selection of Ion Selective Electrodes () to suit a wide variety of applications. Each electrode has a typical response time of 20 to 30 seconds but will vary
More informationG8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method
G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality
More informationRoHS Test Methods. Presented by: Bruce Peterson
RoHS Test Methods Presented by: Bruce Peterson Motivation for Presentation The EU RoHS directive takes effect July 1, 2006 Customer confusion about - Scope of directive How much testing needs to be performed
More informationFP628. Nitrogen / Protein Determination by Combustion. Rev 1-6/8/11
FP628 Nitrogen / Protein Determination by Combustion Rev 1-6/8/11 Presentation Outline LECO Background N Determination FP628 Theory of Operation Specifications Advantages Software Data LECO Background
More informationInstrumentation. (Figure 2)
X-Ray Fluorescence Lab Report Nydia Esparza Victoria Rangel Physics of XRF XRF is a non destructive analytical technique that is used for elemental and chemical analysis. X-Ray Fluorescence Spectroscopy
More informationAdapter Catalog MOBILE METAL ANALYZER. SPECTRO isort and SPECTROTEST
Adapter Catalog MOBILE METAL ANALYZER SPECTRO isort and SPECTROTEST Testing Adapters for Mobile Metal Analyzers A full range of metal analyzer products for onsite metal analysis tasks SPECTRO isort SPECTROTEST
More informationICP Operations Guide. A Guide for using ICP-OES and ICP-MS. by Paul R. Gaines, PhD
ICP Operations Guide A Guide for using ICP-OES and ICP-MS by Paul R. Gaines, PhD Inorganic Ventures has over twenty-five years experience specializing in the manufacturing of inorganic certified reference
More informationQA/QC. Standard methods in field. QA/QC in the field. QA/QC in analysis
QA/QC To identify, measure and keep systematic and random errors under control in planning, sampling, analysis and reporting of data. Quality assurance = how samples and data are collected and managed.
More informationUSE OF REFERENCE MATERIALS IN THE LABORATORY
USE OF REFERENCE MATERIALS IN THE LABORATORY What is a reference material? A general definition of a reference material is a material or substance one or more of whose property values are sufficiently
More informationNeutralization of Acid Mine Drainage Using Stabilized Flue Gas Desulfurization Material
Neutralization of Acid Mine Drainage Using Stabilized Flue Gas Desulfurization Material W. Wolfe 1, C.-M. Cheng 1, R. Baker 1, T. Butalia 1, J. Massey-Norton 2 1 The Ohio State University, 2 American Electric
More informationSolutions and Dilutions
Learning Objectives Students should be able to: Content Design a procedure for making a particular solution and assess the advantages of different approaches. Choose the appropriate glassware to ensure
More informationHigh Sensitivity ICP-MS: Overcome the problem of complex samples
High Sensitivity ICP-MS: Overcome the problem of complex samples Meike Hamester, Andrew Toms and René Chemnitzer Bruker Daltonics Berlin, Germany - Milton, Canada Historical Product Roadmap 2003 2005 2010
More informationMercury Determination in House Dust, NIST SRM-2584, USEPA Method 7473, Using the Teledyne Leeman Labs Hydra II C Combustion CVAAS
Application Note - AN1507 Mercury Determination in House Dust, NIST SRM-2584, USEPA Method 7473, Using the Teledyne Leeman Labs Hydra II C Combustion CVAAS Page 1 Jeff Forsberg, Product Manager, John McQuatters,
More informationThe Sievers 900 Series TOC Analyzers
GE Water & Process Technologies Analytical Instruments The Sievers 900 Series TOC Analyzers imagination at work Delivering Next-Generation Ease of Use, Productivity, and Reliability The Sievers* 900 Series
More informationSampling and preparation of heterogeneous waste fuels?
Sampling and preparation of heterogeneous waste fuels? Is it possible to accomplish a representative and relevant composition data? Evalena Wikström, Lennart Gustavsson and Jolanta Franke Aim of the project
More informationWork Assignment 5-03. Prepared for: Office of Air Quality Planning and Standards U.S. Environmental Protection Agency Research Triangle Park, NC
ERG No.: 0143.04.005 EPA Contract No.: 68-D-00-264 Standard Operating Procedure for the Determination of Metals In Ambient Particulate Matter Analyzed By Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
More informationCONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in
More informationMODERN ATOMIC THEORY AND THE PERIODIC TABLE
CHAPTER 10 MODERN ATOMIC THEORY AND THE PERIODIC TABLE SOLUTIONS TO REVIEW QUESTIONS 1. Wavelength is defined as the distance between consecutive peaks in a wave. It is generally symbolized by the Greek
More informationNITRIC OXIDE and NITROGEN DIOXIDE 6014
NITRIC OXIDE and NITROGEN DIOXIDE 6014 NO MW: 30.01 CAS: 10102-43-9 RTECS: QX0525000 46.01 10102-44-0 QW9800000 METHOD: 6014, Issue 1 EVALUATION: FULL Issue 1: 15 August 1994 OSHA : 25 ppm NO; C 1 ppm
More informationDevelop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate
Cantaurus, Vol. 7, 5-8, May 1999 McPherson College Division of Science and Technology Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Janet Bowen ABSTRACT Sulfate is used in
More informationChapter 8 - Chemical Equations and Reactions
Chapter 8 - Chemical Equations and Reactions 8-1 Describing Chemical Reactions I. Introduction A. Reactants 1. Original substances entering into a chemical rxn B. Products 1. The resulting substances from
More informationThe Periodic Table: Periodic trends
Unit 1 The Periodic Table: Periodic trends There are over one hundred different chemical elements. Some of these elements are familiar to you such as hydrogen, oxygen, nitrogen and carbon. Each one has
More information