AB/AG. General purpose direct acting 2, 3 port solenoid valve. (General purpose valve) For air, vacuum, water, oil CONTENTS.

Size: px
Start display at page:

Download "AB/AG. General purpose direct acting 2, 3 port solenoid valve. (General purpose valve) For air, vacuum, water, oil CONTENTS."

Transcription

1 / (eneral purpose valve) eneral purpose direct acting, 3 port solenoid valve For air, vacuum, water, oil N/ US/ F/ F/ Overview The general purpose valve series enables control of various types of fluids including water, air, oil and vacuums. In addition to the high reliability and high quality of the valve, a variety of options and variations are available. Features Various working fluids control Various types of fluids can be handled by selecting the proper body material and sealant. Wide option range Including open frame, coil with diode and terminal boxes. great variety of series and variations Including direct acting compact type Rc/8 (port size) to Rc. CONTENTS Series variation 0 Coil selection guide Safety precautions port solenoid valve Discrete valve NC (normally closed) type 6 3/ NC (normally closed) type 30 NO (normally open) type 30 7 (large bore size) NC (normally closed) type Manifold 3/35, /5 NC (normally closed) type 8 NO (normally open) type 58 3 port solenoid valve Discrete valve 3/ Universal type 66 33/3 NC pressurization type 8 3/ NO pressurization type 0 Manifold 3*/* (common supply / individual exhaust type) Universal type 7 35*/5* (common supply / separate flow type) Universal type 7 33*/3* (common supply / individual exhaust type) NC pressurization type 9 3*/* (actuator) NO pressurization type 0 Electronic Catalog file list 8 lways read the precautions in the Introduction and page before starting use. FV FW/ F FL P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Direct acting, 3 port solenoid valve

2 eneral purpose valve variation Series variation eneral purpose direct acting, 3 port solenoid valve No. of port port Model 3// Structure Discrete ctuation NC (normally closed) type ir Low vacuum (.33 x 0 Pa (abs)) 7 3 NO (normally open) type 7 NC (normally closed) type 3 35 Manifold NC Common supply (normally closed) Individual supply type Common supply 5 Individual supply NO (normally open) type Common supply 3 port 3 Discrete Universal type 33 NC pressurization type 3 3 NO pressurization type Manifold ctuator Manifold Common supply / Universal type individual exhaust Common supply / separate flow Common supply / individual exhaust Common supply / separate flow NC pressurization type Common supply / individual exhaust 3 ctuator NO pressurization type

3 Working fluid Water Kerosene Oil (50 mm /s or less) ot water Port size Steam Rc/8 Rc/ Rc3/8 Rc/ Rc3/ Rc Page 6 N/ US/ F/ F/ * * 30 FV * * * * * FW/ F * * * * * * *3 * *3 * *3 * *3 * * * * * * * * * * * * * * * * * * * *3 7 * *3 7 * * *3 *3 7 * * *3 *3 7 * *3 9 * * *3 *3 9 * *3 0 * * *3 *3 0 * Refer to page for details on the coil system. *: 0 mm /s for 7 Series. *: Port : Rc/, port C: Rc3/8 *3: indicates the NO port. *: Refer to each ow to order column for the thread types. FL P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Direct acting, 3 port solenoid valve

4 Coil selection guide Coil housing types and selection guide wide variety is available to match applications. Refer to the structure and features to select the optimum model. Direct acting, 3 port solenoid valve (///) eat proof class mold DC and C (50/60 z common) eat proof temperature 30 C Protection property symbols: IP6 or equivalent Outdoor use not available rommet lead wire Lead wire length 300 mm ppearance lank 6C eat proof class mold eat proof class mold DC and C (50/60 z common) eat proof temperature 30 C Protection property symbols: IP6 or equivalent Outdoor use not available DC and C (50/60 z common) eat proof temperature 30 C Protection property symbols: IP65 or equivalent Outdoor use not available Lead wire DIN terminal box Easy wiring and maintenance Reliable electric protection (ground terminal) Light available (optional-00/00 VC and VDC only) Lead wire length 300 mm Conduit (CTC9) for direct conduit wiring can be mounted E 6E eat proof class mold DC and C (50/60 z common) eat proof temperature 30 C Protection property symbols: IP or equivalent Outdoor use not available P terminal box Easy wiring Light available (optional-00/00 VC and /00 VDC only) 3M 3N eat proof class mold DC and C (50/60 z common) eat proof temperature 30 C Protection property symbols: IP65 or equivalent Outdoor use not available P terminal box Easy wiring Light available (optional-00/00 VC and /00 VDC only) 3I 3J Coil variation eat proof class taped C dedicated (50/60 z common) igh temperature fluid and high ambient temperature available eat proof temperature 80 C Protection property symbols: IP00 Outdoor use not available Lead wire Lead wire length 300 mm Conduit (CTC9) for direct conduit wiring can be mounted Open frame type eat proof class mold with diode diode is mounted on the coil section for direct-current conversion (C-DC conversion) Perfect for places where beat can be a problem C dedicated (50/60 z common) eat proof temperature 30 C Protection property symbols: IP65 or equivalent Outdoor use not available Lead wire P terminal box Easy wiring Light available (optional-00/00 VC only) Lead wire length 300 mm Conduit (CTC9) for direct conduit wiring can be mounted M N 5 eat proof class mold with diode diode is mounted on the coil selection for direct-current conversion (C-DC conversion) Perfect for places where beat can be a problem C dedicated (50/60 z common) eat proof temperature 30 C Protection property symbols: IP or equivalent Outdoor use not available P terminal box Easy wiring Light available (optional-00/00 VC only) 5M 5N eat proof class mold with diode diode is mounted on the coil selection for direct-current conversion (C-DC conversion) Perfect for places where beat can be a problem C dedicated (50/60 z common) eat proof temperature 30 C Protection property symbols: IP65 or equivalent Outdoor use not available P terminal box Easy wiring Light available (optional-00/00 VC only) 5I 5J Conduit Use a conduit (CTC9 or /) when using direct conduit wiring for the open frame lead wire.

5 Repair parts table per coil option Coil option symbol Voltage Repair parts Plunger assembly Core assembly Coil assembly ctuator assembly * N/ 0 or blank C US/ 6C *, *3 DC F/ F/ E E 6E 6 6 *, *3 C DC DC FV FW/ F 3 C DC FL 3M 3N 3I 3J C DC C DC C P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ M N 5 5M 5N 5I 5J C C C C *: The actuator assembly includes the coil assembly, core assembly and plunger assembly. *: s 6C, 6E, 6 and 6 are dedicated parts, they are provided as part of the actuator assembly. *3: It is available only for. MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Direct acting, 3 port solenoid valve

6 Safety precautions lways read this section before starting use. Direct acting, 3 port solenoid valve (///) Working fluid () Consult with CKD before using this valve for active gas (combustion gas, acetylene gas, etc.). () Valves for LP (propane gas, butane gas) are available as custom order, so consult with CKD. (3) When using this valve for dry air or inert gas, the life can be shortened considerably due to wear. Use a valve for dry air. () This valve cannot be used for maintaining the vacuum. Consult with CKD when the vacuum needs to be maintained. 3 WRNIN Caution Design & Selection Continuous energizing Use the NO pressurization type when using the 3 port valve in a continuously energized state with the NO port pressurized. When continuously energizing the universal or NC pressurization type, use a fluoro rubber seal. Suction sound With the C voltage specifications, a large suction sound may be heard momentarily after energizing. To avoid the suction sound, select the coil with diode or the DC voltage. The suction sound will drop. Fluid viscosity The fluid viscosity must be 50 mm /s or less. Malfunctions could occur if the viscosity is higher than 50 mm /s. Leakage current from other fluid control components When operating the solenoid valve with a programmable controller, etc., check that the output leakage current from the programmable controller is within the following specifications. Failure to observe this could lead to malfunctions. Voltage, C C diode DC 00 V 00 V 00 V 00 V V V 6 m or less 3 m or less m or less Triode C switch Programmable controller side m or less CR circuit C R m or less Leakage current Solenoid valve m or less CUTION When Using Manual operation lways observe the following points when using a manual override. <For NC (normally closed) type> Opening: Insert a flat-tip screwdriver into the slit on the manual shaft, and turn it approx. 0 to the right or left. The plunger will rise up and the valve will open. (For the 3 port valve, the NC side valve seat will open and the NO side valve seat will close.) The open state is held even when the screwdriver is removed. lways return the valve to the original position after use. Closing: Turn the manual shaft from the open position to the vertical position. The plunger will lower and the valve will close. (For the 3 port valve, the NC side valve seat will close and the NO side valve seat will open.) (Refer to the following drawings.) C O O C Valve closed Valve opened Valve opened <For NO (normally open) type> () Closing the valve with manual operations The manual shaft is threaded, so hold the manual dial and rotate the shaft clockwise. When the manual dial has been rotated downward 5 to 6 mm and no longer rotates, the solenoid valve will switch to closing operation. () Resetting (when not using manual override) lways rotate the manual dial counterclockwise and return it to the highest point. C O Manual dial Manual shaft Right-handed thread Installation, Piping & Wiring CUTION Piping () lways hold the socket with a spanner, etc., if the NO side is a socket. () When passing steam, steam generated from a boiler will contain a large amount of drainage. lways install a drain trap. (3) When passing steam, water replenished to the boiler will contain matters such as "calcium salt" and "magnesium salt". These matters will react with oxygen and carbon oxide causing scales and sludge, so always install a "water softener" and a filter for steam. Wiring () Refer to page 53 in the Introduction for details on connecting the terminal box. CUTION Maintenance When disassembling or assembling, tighten the core assembly and socket with the following tightening torques. Core assembly tightening torque 30 to 5 N m 30 to 5 N m Socket tightening torque - 8 to 6 N m Nut tightening torque 8 to 6 N m 8 to 6 N m

7 CUTION Working environment IP65 (IEC6059 (IEC59:989-)) standards are applied to the test. void use in conditions where water or cutting oil could directly contact the valve. N/ US/ F/ F/ FV Explanation of protection property symbols and examination method of IP65 Protective structure Note: IP-65 is a standard as followings. IEC (International Electrotechnical Commission) standards st characteristic number (protection grade for foreign solid) rade Degree of protection Dust proof type Powder and dust do not enter inside. 6 IP-** Protection property symbols (International Protection) nd characteristic number (protection grade for entry of water) rade Degree of protection Overview of test method (fresh water is used) 5 Protection for jet No harmful effects occur even when water is sprayed with nozzles from all directions. (IEC6059 (IEC59:989-)) Using the following test device, spray water for minute per m of test sample (exterior) surface area from all directions, for a total of 3 minutes or more..5 to 3 m.5 L/min. Spray nozzle inner diameter: ø6.3 mm FW/ F FL P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Direct acting, 3 port solenoid valve

8 Direct acting port solenoid valve (general purpose valve) Series NC (normally closed) type Port size: Rc/8, Rc/ JIS symbol OUT IN Common specifications Item Working fluid Working pressure differential range Max. working pressure Withstanding pressure (water) Fluid temperature mbient temperature eat proof class tmosphere Valve structure Valve seat leakage Mounting attitude MPa MPa MPa C C cm 3 /min. (NR) ir, water, kerosene, oil (50 mm /s or less) 0 to.5 (refer to max. working pressure differential in individual specifications.) to 0 (no freezing) -0 to 50 Place free of corrosive gas and explosive gas Direct acting poppet structure 0. or less Free Individual specifications Item Orifice Port size (mm) Rc/8 Rc/ Max. working pressure differential (MPa) ir Water, kerosene Oil (50 mm /s) C DC C DC C DC Rated voltage 00 VC 50/60 z 0 VC 60 z 00 VC 50/60 z 0 VC 60 z pparent power (V) Power consumption (W) olding Starting C DC 50 z 60 z 50 z 60 z 50/60 z /. 7 Flow characteristics NC (normally closed) type Port size Rc/8 Rc/ Orifice (mm) Flow characteristics C [dm 3 /(s bar)] b Cv flow factor *: Effective sectional area S and sonic conductance C are converted as S 5.0 x C.

9 Series ow to order 0 00 C00V Port size Orifice C ody/sealant combination * * D Option E Rated voltage *3 Symbol Port size lank Orifice Std. Option Rc/8 Rc/ ø.5 ø ø3 ø C ody/sealant combination ody lank 00 luminum rass None Mounting plate Descriptions Sealant Nitrile rubber Fluoro rubber Nitrile rubber Fluoro rubber Refer to page 36 in the Introduction for details on the material combinations. D Option E Rated voltage C00V 00 VC 50/60 z, 0 VC 60 z C00V 00 VC 50/60 z, 0 VC 60 z Remarks ir, kerosene, oil ir, kerosene, oil ir, water, kerosene, oil ir, water, kerosene, oil Consult with CKD for other optional voltages. N/ US/ F/ F/ FV FW/ F FL P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ <Example of model number> C00V : Port size: Rc/8 Orifice: ø.5 C ody/sealant combination: : ody - brass, sealant - nitrile rubber D Option: Mounting plate E Rated voltage: 00 VC 50/60 z, 0 VC 60 z Note on model no. selection *: For (orifice ø.5), only C or is available. *: When using for water, select the brass (option symbol: or ) body. *3: The voltage fluctuation must be within ±0% of the rated voltage. *: Leave C blank for standard. owever, to select 00 for D, indicate 0 for C. MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Direct acting port solenoid valve

10 Series Internal structure and parts list Series 3 IN OUT No. Parts name Material Coil Core assembly Stainless steel 3 O ring Shading coil Fluoro rubber Copper 5 Plunger spring Stainless steel Plunger Sealant ody Stainless steel Nitrile or fluoro rubber luminum or brass Dimensions -0/0- to 5-* Mounting plate -0/0- to 5-*00 * Lead wire length 50 mm ø (6) ø5.5 -ø6 0 -Rc/8 or / Dimensions shown in ( ) are for brass body. 8 Mounting plate No. E M5 depth 8

11 3 Series Discrete direct acting port solenoid valve (general purpose valve) 3 Series NC (normally closed) type Series NO (normally open) type Port size: Rc/8 to Rc/ JIS symbol Common specifications 3/: NC (normally closed) type Item Standard specifications Optional specifications OUT Working fluid ir, low vacuum (.33 x 0 Pa (abs)), water, kerosene, oil (50 mm /s or less) ot water Steam Working pressure differential range MPa Withstanding pressure (water) MPa 0 to 5 (refer to max. working pressure differential in individual specifications. ) 5 IN Fluid temperature (Note ) C -0 to 60-0 to 90-0 to 8 : NO (normally open) type mbient temperature eat proof class C -0 to 60-0 to 00 OUT tmosphere Valve structure Place free of corrosive gas and explosive gas Direct acting poppet structure IN Valve seat leakage cm 3 /min. (NR) 0. or less (air) 300 or less (air) Mounting attitude Free ody, sealant rass, nitrile rubber rass, ethylene propylene diene rubber rass, PTFE Note : No freezing Individual specifications Item Port size Orifice (mm) NC (normally closed) type Rc/ Rc/ Rc/ Rc3/8 Rc3/8 Rc/ NO (normally open) type Rc/ Rc3/ Max. working pressure differential (MPa) ir Water, hot water, kerosene Oil (50 mm /s) Steam C DC C DC C DC C (0.03) (0.03) 0.05 (0.03) *8 *8 * Max. working pressure (MPa) 5 5 (fluid; for steam) Rated voltage 00 VC 50/60 z 0 VC 60 z 00 VC 50/60 z 0 VC 60 z VDC VDC 8 VDC 00 VDC 5 (fluid; for steam) pparent power (V) Power consumption (W) olding Starting C 50 z 60 z 50 z 60 z 50/60 z / /5.7 (8.) * / () *: The model numbers above show the basic port size (Rc) and orifice diameter. Refer to ow to order for other combinations (e.g., for steam). *: The port size symbol is 0 for Rc/8 (6), 0 for Rc/ (8), 03 for Rc3/8 (0) and 0 for Rc/ (5). *3: Refer to DC column for the max. working pressure differential of coil with diode. *: The voltage fluctuation must be within ±0% of the rated voltage. *5: Power consumption of coil housing E// is indicated. *6: When using with a low vacuum, vacuum the OUT port side. *7: Power consumption of coil housing 6C/6E/6/6 is indicated. *8: The DC voltage of coil housing E// and the max. working pressure differential of coil housing 6C/6/6 are indicated. DC Weight (kg) (Rc/) 5 () *5 (Rc3/8) (7) * (Rc/) 0.5 (Rc3/8)

12 3 Series Optional specifications (fluid temperature, ambient temperature, valve seat leakage) Sealant material Fluoro rubber Ethylene propylene diene rubber PTFE Coil (heat proof class) Fluid temperature (Note ) C mbient temperature C Valve seat leakage cm 3 /min. (NR) -0 to 60-0 to 60-0 to 90-0 to 00 (Note ) -0 to 60-0 to 60-0 to 90-0 to 00 (Note ) -0 to 60-0 to 60-0 to 8-0 to 00 (Note ) 0. or less (air) 300 or less (air) Note : No freezing Note : The range is -0 to 80 C when using the P terminal box with indicator light for the coil housing. N/ US/ F/ F/ Flow characteristics NC (normally closed) type NO (normally open) type Port size Rc/8 Rc/ Rc/ Rc3/8 Rc3/8 Rc/ Rc/ Rc3/8 Orifice (mm) *: Effective sectional area S and sonic conductance C are converted as S 5.0 x C. *: Values shown in ( ) are for stainless steel body Flow characteristics C [dm 3 /(s bar)] b Cv flow factor (.5). (.9) 3.0 (.6) (.5). (.9) 3.0 (.6).8 (.6) 9.3 (8.) (.5). (.9) 3.0 (.6).8 (.6) (7) 8 (7) (0.38) (7) 8 (7) (0.38) 0.9 (0.37) 0.36 (0.3) (7) 8 (7) (0.38) 0.9 (0.37) (0) 0.5 (8) 0.8 (0.6) (0) 0.5 (8) 0.8 (0.6) (0.8).88 (.5) (0.6) (0.8) FV FW/ F FL P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Direct acting port solenoid valve

13 3 Series ow to order NC (normally closed) type 3 Port size: Rc/ Orifice: ø3 The combinations indicated with in the above table are available. C ody/sealant combination: ody - brass, sealant - nitrile rubber D Coil housing: rommet lead wire E to I : lank J Rated voltage: 00 VC 50/60z, 0 VC 60z Note on model no. selection Note on C 0 Port size S C00V Orifice D Coil housing Other options J Voltage E Manual override (locking) Surge suppressor F Mounting plate I Copper and PTFE free C ody/sealant combination * * *3 * *5 *6 *7 <Example of model number> C00V : 3 <Example of model number> -0-3-C00V : Port size Orifice Port size: Rc/ Orifice: ø3 C ody/sealant combination: ody - brass, sealant - nitrile rubber D Coil housing: rommet lead wire E Manual override (locking): Selected F to : lank I Surge suppressor: Selected J Rated voltage: 00 VC 50/60z, 0 VC 60z Symbol Descriptions Symbol Descriptions Symbol ø.5 ø ø3 ø3.5 ø ø5 ø7 ø0 C ody/sealant combination ody Sealant Treatment Remarks lank C V D E F W J K P L M N R D to J Std. rass or bronze Option Stainless steel Stainless steel rass Rc/8 Rc/ Rc3/8 Rc/ 3 Nitrile rubber Fluoro rubber PTFE Fluoro rubber Nitrile rubber Fluoro rubber PTFE Fluoro rubber Nitrile rubber Fluoro rubber PTFE Ethylene propylene diene rubber Nitrile rubber Fluoro rubber PTFE Ethylene propylene diene rubber *: *: *3: *: *5: *6: *7: /8 / 3/8 / - Vacuum inspection - Vacuum inspection Oil free ir, water, low vacuum, kerosene (up to 60 C) ir, low vacuum, kerosene (up to 90 C *) Steam (up to 8 C *) Medium vacuum ir, water, low vacuum, kerosene (up to 60 C) ir, low vacuum, kerosene (up to 90 C *) Steam (up to 8 C *) Medium vacuum ir, water, low vacuum, kerosene (up to 60 C) ir, low vacuum, kerosene (up to 90 C *) Steam (up to 8 C *) ot water (up to 90 C *) ir, water, low vacuum, kerosene (up to 60 C) ir, low vacuum, kerosene (up to 90 C *) Steam (up to 8 C *) ot water (up to 90 C *) 3 Low pressure large flow rate Refer to page 36 in the Introduction for details on the material combinations. Refer to the following page for details on the coil housing, other options and voltage, etc. N N 3N N Descriptions /8NPT /NPT 3/8NPT /NPT Leave blank for standard. owever, to select options in D to I, indicate 0 for C. When, M or N is selected for D. The body for the low pressure large flow rate is bronze (standard) or stainless steel (optional). For option symbols V and W, vacuum is inspected at "leakage amount:.33 x 0-6 Pa m 3 /s or less". When C of the low pressure large flow rate is V or W, DC voltage is not available. The ethylene propylene diene rubber seal combination (C P/R) cannot be used with air. (Compressed air contains oil, and ethylene propylene diene rubber is not oil-resistant. ) When C is C, F, K, P, N or R, the coil housings D 6C, 6E, 6 and 6 cannot be selected.

14 3 Series For D to J, the combinations indicated with symbols can be manufactured. Note that if options E to I are not required, no symbol is indicated. D Coil housing E F Other options I J Rated voltage Cable gland Conduit Descriptions (Marine cable gland) (Conduit pipe) Descriptions -5a -5b -5c CTC9 / lank E 3 3M 3N 3I 3J M N 5 5M 5N 5I 5J 6C 6E 6 6 lank 6C Std. Option rommet lead wire DIN terminal box DIN terminal box DIN terminal box + small light (Pg) Open frame type Open frame type (heat proof class ) (/) (Pg) Lead wire P terminal box (/) P terminal box + light (/) P terminal box (IP65 or equivalent) (/) (/) P terminal box + light (IP65 or equivalent) Lead wire P terminal box P terminal box + light Lead wire P terminal box (/) (/) Open (/) frame type P terminal box + light (/) (diode integrated) P terminal box (IP65 or equivalent) (/) P terminal box + light (IP65 or equivalent) (/) rommet lead wire 7W DIN terminal box (/) 7W DIN terminal box (Pg) 7W DIN terminal box + small light (Pg) 7W Manual override (locking) Mounting plate rommet lead wire 300 mm S P6 D E F D E F D E F Surge suppressor S S S Copper and PTFE free P6 P6 P6 P6 00 VC, 00 VC 00 VC, 00 VC VDC, VDC, 8 VDC, 00 VDC 00 VC, 00 VC, VDC 00 VC, 00 VC VDC, VDC, 8 VDC, 00 VDC 00 VC, 00 VC, VDC, VDC, 00 VDC 00 VC, 00 VC, VDC, VDC, 8 VDC, 00 VDC 00 VC, 00 VC, VDC, VDC, 00 VDC 00 VC, 00 VC 00 VC, 00 VC VDC, VDC VDC Refer to the following precautions for D to J. Conduit (CTC9) (/) N/ US/ F/ F/ FV FW/ F FL P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP E 6E M 3N M N 5M 5N 3I 3J 5I 5J DIN terminal box Open frame type grommet lead wire 300 mm (heat proof class ) 5 (diode integrated) Open frame P terminal box M, N (heat proof class ) 5M, 5N (diode integrated) Open frame P terminal box (IP65 or equivalent) 5I, 5J (diode integrated) Refer to page for coil selection. Note on model no. selection Note on D *8: Leave blank for the standard coil housing. owever, to select options in E to I, indicate 00 for D. *9: 5, 5M, 5N, 5I and 5J are coils for which C power is converted to DC with a diode. *0: DC coil for steam is available for. Contact CKD for more information. *: 6C, 6E, 6 or 6 can be selected for only. *: The coil housings 6C, 6E and 6 are VDC and VDC dedicated. 6 is VDC dedicated. Note on E to I *3: The manual override (E ) is not available for the low pressure large flow rate *: When C is C, F, K, N, V or W, the manual override (E ) is not available. *5: Select one among D, E, F, and for. *6: The surge suppressor is an accessory for the lead wire coil. When selecting a coil with terminal box, the surge suppressor is mounted in the terminal box. *7: s standard, the surge suppressor is incorporated in the coil with diode and the VDC coil (D /6), so the surge suppressor symbol S cannot be selected. *8: I P6 is available only when C is L, M or R. *9: Tropicalization (rust-proof coating) is available as a measure against rust. Contact CKD for more information. Note that the tropicalization is not available when the manual override option and the coil option 6C/6E/6/6 are selected. Note on J *0: 00 VC coil is compatible with 00 VC 50/60 z and 0 VC 60 z, and 00 VC coil is compatible with 00 VC 50/60 z and 0 VC 60 z. Note that the coils D 5/5M/5N/5I/5J can be used only with 00 VC 50/60 z or 00 VC 50/60 z. *: For voltages other than above, consult with CKD. *: The lead wire is available in the standard 300 mm length, and 500 mm, 000 mm, 000 mm and 3000 mm lengths. Contact CKD for more information. C/ MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Direct acting port solenoid valve

15 3 Series ow to order NO (normally open) type 0 L 3 P6 C00V Port size Orifice <Example of model number> -0--C00V : Port size: Rc/ Orifice: ø.5 C ody/sealant combination: D Coil housing: E to I : J Rated voltage: D Coil housing Other options E Manual override (locking) Surge suppressor F Mounting plate C ody/sealant combination * * *3 * ody - brass, sealant - nitrile rubber rommet lead wire lank 00 VC 50/60z, 0 VC 60z J Voltage I Copper and PTFE free Symbol Descriptions Port size 0 Rc/ 03 Rc3/8 Orifice Std. Option D to J ø.5 ø ø3 ø3.5 ø ø5 ø7 C ody/sealant combination ody Sealant Treatment Remarks lank Nitrile rubber ir, water, low vacuum, kerosene (up to 60 C) Fluoro rubber - ir, low vacuum, kerosene (up to 90 C *) C PTFE Steam (up to 8 C *) V Fluoro rubber Vacuum inspection Medium vacuum D Nitrile rubber ir, water, low vacuum, kerosene (up to 60 C) E Fluoro rubber - ir, low vacuum, kerosene (up to 90 C *) F PTFE Steam (up to 8 C *) W Fluoro rubber Vacuum inspection Medium vacuum Nitrile rubber ir, water, low vacuum, kerosene (up to 60 C) J Fluoro rubber ir, low vacuum, kerosene (up to 90 C *) K PTFE Steam (up to 8 C *) P Ethylene propylene diene rubber ot water (up to 90 C *) L Nitrile rubber Oil free ir, water, low vacuum, kerosene (up to 60 C) M Fluoro rubber ir, low vacuum, kerosene (up to 90 C *) N PTFE Steam (up to 8 C *) R Ethylene propylene diene rubber ot water (up to 90 C *) rass Stainless steel Stainless steel rass Symbol 3 Descriptions / 3/8 Symbol N 3N Descriptions /NPT 3/8NPT Refer to page 36 in the Introduction for details on the material combinations. Refer to the following page for details on the coil housing, other options and voltage, etc. <Example of model number> S-C00V : Port size: Rc3/8 Orifice: ø5 C ody/sealant combination: ody - brass, sealant - nitrile rubber D Coil housing: rommet lead wire E Manual override (locking): Selected F : lank Surge suppressor: Selected J Rated voltage: 00 VC 50/60z, 0 VC 60z Note on model no. selection Note on C *: Leave blank for standard. owever, to select options in D to I, indicate 0 for C. *: When, M or N is selected for D. *3: For option symbols V and W, vacuum is inspected at "leakage amount:.33 x 0-6 Pa m 3 /s or less". *: The ethylene propylene diene rubber seal combination (C P/R) cannot be used with air. (Compressed air contains oil, and ethylene propylene diene rubber is not oil-resistant. )

16 3 Series For D to J, the combinations indicated with symbols can be manufactured. Note that if options E to I are not required, no symbol is indicated. D Coil housing E F Other options I J Rated voltage Cable gland Conduit Descriptions (Marine cable gland) (Conduit pipe) Descriptions -5a -5b -5c CTC9 / lank E 3 3M 3N 3I 3J M N 5 5M 5N 5I 5J lank E Std. Option rommet lead wire DIN terminal box DIN terminal box (/) (Pg) DIN terminal box + small light (Pg) Lead wire P terminal box (/) Open frame type P terminal box + light (/) P terminal box (IP65 or equivalent) (/) P terminal box + light (IP65 or equivalent) (/) Open Lead wire frame type P terminal box (/) (heat proof class ) P terminal box + light (/) Lead wire Open P terminal box (/) frame type P terminal box + light (/) (diode integrated) P terminal box (IP65 or equivalent) (/) P terminal box + light (IP65 or equivalent) (/) Manual override (locking) Mounting plate rommet lead wire 300 mm DIN terminal box D E F D E F D E F S S S Surge suppressor Copper and PTFE free P6 P6 P6 P6 00 VC, 00 VC 00 VC, 00 VC VDC, VDC, 8 VDC, 00 VDC 00 VC, 00 VC, VDC 00 VC, 00 VC VDC, VDC, 8 VDC, 00 VDC 00 VC, 00 VC, VDC, VDC, 00 VDC 00 VC, 00 VC, VDC, VDC, 8 VDC, 00 VDC 00 VC, 00 VC, VDC, VDC, 00 VDC 00 VC, 00 VC 00 VC, 00 VC Refer to the following precautions for D to J. Conduit (CTC9) (/) N/ US/ F/ F/ FV FW/ F FL P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ MX/ 3 5 3M 3N M N 5M 5N 3I 3J 5I 5J Open frame type grommet lead wire 300 mm (heat proof class ) 5 (diode integrated) Open frame P terminal box M, N (heat proof class ) 5M, 5N (diode integrated) Open frame P terminal box (IP65 or equivalent) 5I, 5J (diode integrated) * Refer to page for coil selection. Note on model no. selection Note on D *5: Leave blank for the standard coil housing. owever, to select options in E to I, indicate 00 for D. *6: 5, 5M, 5N, 5I and 5J are coils for which C power is converted to DC with a diode. Note on E to I *7: When C is C, F, K, N, V or M, the manual override (E ) is not available. *8: Select one among D, E, F, and for. *9: The surge suppressor is an accessory for the lead wire coil. When selecting a coil with terminal box, the surge suppressor is mounted in the terminal box. *0: s standard, the surge suppressor is incorporated in the coil with diode and the VDC coil (D ), so the surge suppressor symbol S cannot be selected. *: I P6 is available only when C is L. *: Tropicalization (rust-proof coating) is available as a measure against rust. Contact CKD for more information. Note that the tropicalization is not available when the manual override option is selected. Note on J *3: 00 VC coil is compatible with 00 VC 50/60 z and 0 VC 60 z, and 00 VC coil is compatible with 00 VC 50/60 z and 0 VC 60 z. Note that the coils D 5/5M/5N/5I/5J can be used only with 00 VC 50/60 z or 00 VC 50/60 z. *: For voltages other than above, consult with CKD. *5: The lead wire is available in the standard 300 mm length, and 500 mm, 000 mm, 000 mm and 3000 mm lengths. Contact CKD for more information. Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Direct acting port solenoid valve

17 3 Series Internal structure and parts list 3 Series -0/03- to IN OUT 8-03/ No. 3 Parts name Material Coil Core assembly SUS05 or equivalent, 36L, 03 * Stainless steel Shading coil Cu (g for stainless steel body) Copper (silver for stainless steel body) Plunger SUS05 or equivalent Stainless steel No. Parts name Material 5 Plunger spring SUS30 Stainless steel NR (FKM, EPDM, PTFE) NR: Nitrile rubber 6 O ring (size: S568-09) 37 Sealant NR (FKM, EPDM, PTFE) ( FKM: EPDM: Fluoro rubber PTFE: Tetrafluoroethylene Ethylene propylene resin ) diene rubber 8 ody C377 or CC08 (SCS3) rass or bronze (stainless steel) *: When the body/sealant combination symbol is other than blank or, or when the coil housing is 6C, 6E, 6 or 6, the material is SUS05 or equivalent, 36L, 30. *: ( ) shows option. Note that PTFE is not available for

18 3 Series Internal structure and parts list N/ US/ F/ No. Parts name Material No. Parts name Material Core assembly SUS05 or equivalent, 36L, 30 Stainless steel 6 O ring Coil 3 Plunger SUS05 or equivalent Stainless steel 7 Spring Shading coil Cu (g for stainless steel body) Copper (silver for stainless steel body) 38 ody NR: Nitrile rubber (EPDM: Ethylene propylene diene rubber) 5 Sealant NR (FKM, EPDM, PTFE) 9 NO valve (FKM: Fluoro rubber) (PTFE: Tetrafluoroethylene resin) IN OUT NR (FKM, EPDM, PTFE) (size: S568-09) SUS30 C377 (SUS303) POM (SUS303, PF) NR: Nitrile rubber (EPDM: Ethylene propylene diene rubber) (FKM: Fluoro rubber) (PTFE: Tetrafluoroethylene resin) Stainless steel rass (stainless steel) Option symbol : lank/0/d//l/v/w - polyacetal resin : Other than above - stainless steel, perfluoroalkoxy resin ( ) shows option. F/ FV FW/ F FL P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Direct acting port solenoid valve

19 3 Series Dimensions: 3 Series rommet lead wire type 3-0/0- to 6-* lank F Note : The 3 Series is an open when energized type port solenoid valve. The body and sealant materials are combined according to the working fluid, and the orifice and pressure are selected according to the relation of the required flow rate and pressure. The coil specifications are determined according to the fluid temperature and ambient conditions, allowing the optimum valve to be selected. Note : The dimensions are the same for the or NPT thread port size. D 75 IN OUT 36 -M5 depth 8 8 Rc/8 (0) Rc/ (0) 8 CKD * Lead wire length 300 mm 3-0- to 6-C -0- to 6-C D F 3

20 3 Series Optional dimensions: 3 Series DIN terminal box 3-0/0- to 6-* E C 7.5 * Refer to the grommet lead wire type dimensions on the left page for common dimensions. Open frame lead wire type 3-0/0- to 6-* N/ US/ F/ F/ 39 () D FV FW/ F Voltage C (E//) DC (E//) Dimensions shown in ( ) are for /. C D (50) (5.5) 0.5 FL Open frame type + P terminal box 3-0/0- to 6-* 3 M M 5 N N I J Stainless steel body 3-0/0- to 6- D/E/F/R/W/L/M/N lank ø37.5 D D Open frame type + conduit 3-0/0- to 6-* (56) Manual override (locking) 3-0/0- to 6-*** Figure shows the brass body. IN Manual override OUT (ø37.5) 38 CTC9 (/) Dimensions shown in ( ) are for /. Dimensions shown in ( ) are for stainless steel body. P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order Mounting plate 3-0/0- to 6-*** eneral purpose valve Direct acting port solenoid valve 8 -ø5.5 -ø6 Mounting plate No. E-0006

21 3 Series Dimensions: Series rommet lead wire type -0/03- to 7-* lank 6C F IN OUT C D E -M5 depth 8 Rc/ (0) Rc3/8 (03) 8 CKD * Lead wire length 300 mm -0- to 6-C -0-7-C -03- to 7-C -0- to 6-6C-DC C-DC -03- to 7-6C-DC C D E F rommet lead wire type -03/0-8-* lank 6C F OUT CKD 5 D 93 IN C -0-8-C C-DC C-DC 8 D F M5 Depth 8 Note : Note : Rc3/8 (03) -Rc/ (0) This Series, port solenoid valve, open when energized, is designed to meet the customer's requirement according to working fluid, body and seal materials, relation between flow rate and the required pressure (converted to orifice diameter and pressure), and ambient temperature and conditions (converted to coil specifications). The dimensions are the same for the or NPT thread port size.

22 3 Series Optional dimensions: Series DIN terminal box -0/03/0- to 8-* 6 F E 7.5 * Refer to the grommet lead wire type dimensions on the left page for common dimensions. Open frame lead wire type -0/03/0- to 8-* N/ US/ F/ 39 () I E D F/ FV FW/ Dimensions shown in ( ) are for /. Voltage F I C (E//) DC (E//) DC (6E/6/6) (53.5) 5.5 (5) 56.5 (56) Open frame type + P terminal box -0/03/0- to 8-* 3 M M 5 N N I 03 J Stainless steel body -0/03/0- to 8- D/F/R/W/L/M/N/E -0- to 6-** -0-7-** -03- to 7-** -03/0-8-** Open frame type + conduit -0/03/0- to 8-* 3 5 D (60) E Dimensions shown in ( ) are for /. CTC9 (/) F FL P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ D E Manual override (locking) -0/03- to 7-*** Figure shows the brass body. MX/ Other.P. systems -0- to 6-C -0-7-C -03- to 7-C C -0-8-C Mounting plate -0/03/0- to 8-*** 6 (70) 50 (58) 8 (8) C C D E ø ø5.0 50* *: The max. dimension is ø5. -ø5.5 -ø6 Dimensions shown in ( ) are for mounting plate No.. IN Note: No manual override is available for -03/0-8. K -0- to 6-*** -0-7-*** -03- to 7-*** 36 (ø37.5) 0 (ø5.0) Dimensions shown in ( ) are for stainless steel body. Mounting plate No. E-0006 Mounting plate No. E-0059 Manual override OUT K pplicable model -0/03- to 7 Series Stainless steel body -0- to 6- D/E/F/L/M/N/R/W -03/0-8 Series Stainless steel body D/E/F/L/M/N/R/W -03- to 7- D/E/F/L/M/N/R/W PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Direct acting port solenoid valve

23 3 Series Dimensions: Series rommet lead wire type -0/03- to E <Reference> port direct acting valve, closed when energized, is open when de-energized. This type is commonly used to be continuously energized. The dimensions are the same for the or NPT thread port size. IN OUT D Note : The dimensions are the same for the or NPT thread port size. C Rc/ (0) Rc3/8 (03) -M5 depth 8 8 CKD * Lead wire length 300 mm -0- to to 7 C D E

24 3 Series Optional dimensions: Series DIN terminal box -0/03- to 7-* E F 7.5 * Refer to the grommet lead wire type dimensions on the left page for common dimensions. Open frame lead wire type -0/03- to 7-* N/ US/ F/ F/ 39 () 3 E D FV FW/ F Voltage C DC Dimensions shown in ( ) are for /. F (53.5) (60) -0- to to 7 D E FL Open frame type + P terminal box -0/03- to 7-* 3 M M 5 N N I J Open frame type + conduit -0/03- to 7-* (60) Dimensions shown in ( ) are for /. CTC9 (/) P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP Stainless steel body -0/03- to 7- D/E/F/R/W/L/M/N Manual override (locking) -0/03- to 7-*** C/ MX/ -0- to to 7 Mounting plate -0/03- to 7-*** 6 (70) 50 (58) C D E C D ø ø ø ø5.5 -ø6 E Dimensions shown in ( ) are for mounting plate No.. (3) Code Mounting plate No. E-0006 Mounting plate No. E-0059 Manual override pplicable model -0/03- to 7 Series Stainless steel body -0- to 6- D/E/F/L/M/N/R/W Stainless steel body D/E/F/L/M/N/R/W -03- to 7- D/E/F/L/M/N/R/W Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Direct acting port solenoid valve

25 3 Series Large bore size direct acting port solenoid valve (general purpose valve) 7 Series NC (normally closed) type Port size: Rc/, Rc3/, Rc JIS symbol OUT IN Specifications Item Working fluid ir, water, kerosene, oil (0 mm /s) Working pressure ir C: 0 to 00, DC: 0 to 80 C: 0 to 70, DC: 0 to 0 C: 0 to 0, DC: 0 to 30 range kpa Water, kerosene, oil C: 0 to 80, DC: 0 to 80 C: 0 to 50, DC: 0 to 0 C: 0 to 30, DC: 0 to 30 Withstanding pressure (water) MPa Fluid viscosity mm /s 0 or less Fluid temperature C mbient temperature C Valve seat leakage cm 3 /min. (NR) -5 to 60 (no freezing) -0 to or less (air) Port size Rc/ Rc3/ Rc Orifice mm 5 8 Mounting attitude Limited to vertical position with coil facing upward to horizontal position Electric specifications Rated voltage 00 VC 50/60 z, 00 VC 50/60 z, 0 VC 60 z, 0 VC 60 z, VDC, VDC, 8 VDC, 00 VDC pparent olding (50/60 z) 3/6 power V Starting (50/60 z) 3/06 Power consumption W C: 3/ (50/60 z), DC: 0 Flow characteristics Port size Rc/ Rc3/ Rc Orifice (mm) 5 8 Flow characteristics C [dm 3 /(s bar)] b Cv flow factor S (mm ) *: Effective sectional area S and sonic conductance C are converted as S 5.0 C.

26 7Series ow to order 7 5 C00V N/ Port size F Other options US/ Symbol Port size 5 Rc/ 0 Rc3/ 5 Rc 5 8 J Orifice ody ronze ronze Orifice Stuffing rass rass C ody/sealant combination Descriptions D Coil housing ø (only 7-5 (port size Rc/)) ø5 (only 7-0 (port size Rc3/)) ø8 (only 7-5 (port size Rc)) C ody/sealant combination E Mounting plate Sealant Fluoro rubber Fluoro rubber Treatment D Oil free Voltage D Coil housing E F Other options Rated voltage Cable gland Conduit Descriptions (Marine cable gland) (Conduit pipe) Descriptions -5a -5b -5c CTC9 / C E 3 3M 3N 5 5M 5N Std. Option rommet lead wire DIN terminal box DIN terminal box DIN terminal box + small light Open frame type Open frame type (diode integrated) Lead wire P terminal box P terminal box + light Lead wire P terminal box (/) (Pg) (Pg) (/) (/) (/) P terminal box + light (/) D E F D E F For D to, the combinations indicated with symbols can be manufactured. Note that if options E and F are not required, no symbol is indicated. Mounting plate <Example of model number> 7-5--E-C00V : 7 Port size: Rc/ Orifice: ø C ody/sealant combination: D Coil housing: E Mounting plate: F Other options: Rated voltage: ody - bronze, stuffing - brass, sealant - fluoro rubber DIN terminal box (/) Selected lank 00 VC 50/60z, 0 VC 60z 00 VC, 00 VC 00 VC, 00 VC VDC, VDC, 8 VDC, 00 VDC 00 VC, 00 VC, VDC, 00 VDC 00 VC, 00 VC F/ F/ FV FW/ F FL P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order Note on model no. selection Note on C *: Refer to page 36 in the Introduction for details on the material combinations. Note on D *: Refer to page for coil selection. *3: 5, 5M and 5N are coils for which C power is converted to DC with a diode. *: When working fluid is air, type 5 is recommended. *5: Contact CKD for details on the heat proof class coil. Note on F *6: Select one among D, E, F, and for F. Note on *7: 00 VC coil is compatible with 00 VC 50/60 z and 0 VC 60 z, and 00 VC coil is compatible with 00 VC 50/60 z and 0 VC 60 z. Note that the coils D 5/5K/5 can be used only with 00 VC 50/60 z or 00 VC 50/60 z. *8: For voltages other than above, consult with CKD. *9: Lead wire length is 300 mm. dditional lengths are available in 500 mm increments. Contact CKD for details. eneral purpose valve Discrete direct acting port solenoid valve

27 7 Series Internal structure and parts list 3 IN OUT No. Parts name Material 3 Coil Plunger Wear ring SUS05 PTFE Stuffing assembly C377 (Core assembly) SUS05, Cu Spring pin Main valve Main valve spring ody SUS0 SUS30, FKM SUS30 CC07 Stainless steel Tetrafluoroethylene resin rass Stainless steel, copper Stainless steel Stainless steel, fluoro rubber Stainless steel ronze Dimensions rommet lead wire type 7-*-*-*C Mounting plate 7-*-*-** (300) 8 C D CKD E F J -K C D E F J K Rc/ Rc3/ Rc ø9 ø9 ø

28 7Series Optional dimensions DIN terminal box 7-*-*-* E Open frame lead wire type 7-*-*-* (300) N/ US/ F/ F/ 6.5 (6) 33 FV FW/ F Dimensions shown in ( ) are for /. FL Open frame type + P terminal box 7-*-*-* 3 M 5 N Open frame type + conduit 7-*-*-* 3 5 Dimensions shown in ( ) are for /. P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Discrete direct acting port solenoid valve 5 59 (6) CTC9 (/)

29 Direct acting port solenoid valve, manifold and actuator (general purpose valve) 3/35//5 Series NC (normally closed) type Common supply type (port C pressurization), individual supply type (port pressurization) JIS symbol 3/ (Common supply type / port C pressurization) Port Port OUT OUT IN IN Port C 35/5 (Individual supply type / port pressurization) Port Port IN IN OUT OUT Port C Common specifications Item Working fluid Working pressure differential range Max. working pressure Withstanding pressure (water) Fluid temperature (Note ) mbient temperature eat proof class tmosphere Valve structure Valve seat leakage Mounting attitude ody, sealant Note : No freezing Standard specifications Optional specifications irflow, low vacuum (.33 x 0 Pa (abs)), water, kerosene, oil (50 mm /s or less) ot water Steam MPa 0 to 5 (refer to max. working pressure differential in individual specifications. ) MPa 5 MPa 0 C C -0 to 60-0 to 60-0 to 90-0 to 8-0 to 00 Place free of corrosive gas and explosive gas Direct acting poppet structure cm 3 /min. (NR) 0. or less (air) 300 or less (air) Free rass, nitrile rubber rass, ethylene propylene diene rubber rass, PTFE Individual specifications 3/ / Port size Orifice (mm) Max. working pressure differential (MPa) ir Water, hot water, kerosene Oil (50 mm /s) Steam C DC C DC C DC C Rated voltage 00 VC 50/60 z 0 VC 60 z 00 VC 50/60 z 0 VC 60 z VDC VDC 8 VDC 00 VDC *: The model numbers above show the basic orifice diameter. Refer to ow to order for other combinations (e.g., for steam). *: Refer to ow to order (page 50) and Dimensions (page 5) for the port size. *3: Refer to DC column for the max. working pressure differential of coil with diode. *: The voltage fluctuation must be within ±0% of the rated voltage. *5: Power consumption of coil housing E// is indicated. *6: When using with a low vacuum, vacuum the NO port side. *7: Power consumption of coil housing 6C/6E/6/6 is indicated. pparent power (V) Power consumption (W) olding Starting C DC 50 z 60 z 50 z 60 z 50/60 z / /5.7 (8.) *5 () *5 (7) *7

30 3355 Series Optional specifications (fluid temperature, ambient temperature, valve seat leakage) Sealant Fluoro rubber Ethylene propylene diene rubber PTFE Coil (heat proof class) Fluid temperature (Note ) C mbient temperature C Valve seat leakage cm 3 /min. (NR) -0 to 60-0 to 60-0 to 90-0 to 00 (Note ) -0 to 60-0 to 60-0 to 90-0 to 00 (Note ) -0 to 60-0 to 60-0 to 8-0 to 00 (Note ) 0. or less (air) 300 or less (air) Note : No freezing Note : The range is -0 to 80 C when using the P terminal box with indicator light for the coil housing. N/ US/ F/ F/ Flow characteristics 3/ / Port size *: Effective sectional area S and sonic conductance C are converted as S 5.0 x C. Orifice Flow characteristics (mm) C [dm 3 /(s bar)] b Cv flow factor FV FW/ F FL P/ D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Discrete direct acting port solenoid valve

31 3355 Series ow to order Common supply type (port C pressurization) Individual supply type (port pressurization) Common supply type (port C pressurization) Individual supply type (port pressurization) <Example of model number> 3--3-C00V : 3 (common supply type / port C pressurization) Type of thread: Orifice: ø.5 C Station no.: 3 stations D ody/sealant combination: E F I Coil housing: to : Rated voltage: 5 3 S C00V Type of thread Orifice C Station no. * D ody/sealant combination *3 * *5 *6 ody - brass, sealant - nitrile rubber rommet lead wire lank 00 VC 50/60z, 0 VC 60z E Coil housing Surge suppressor F Manual override (locking) Other options Symbol Type of thread lank Rc N NPT Orifice ø.5 ø ø3 ø3.5 ø ø5 ø7 I Voltage Descriptions C Station no. to 0 0 stations to 0 stations ctuator only D ody/sealant combination ody Sealant Treatment Remarks lank C D E F J K P L M N R Std. Option E to I rass Stainless steel Stainless steel rass Nitrile rubber Fluoro rubber PTFE Nitrile rubber Fluoro rubber PTFE Nitrile rubber Fluoro rubber PTFE Ethylene propylene diene rubber Nitrile rubber Fluoro rubber PTFE Ethylene propylene diene rubber The combinations indicated with in the above table are available. Oil free ir, water, low vacuum, kerosene (up to 60 C) ir, low vacuum, kerosene (up to 90 C *) Steam (up to 8 C *) ir, water, low vacuum, kerosene (up to 60 C) ir, low vacuum, kerosene (up to 90 C *) Steam (up to 8 C *) ir, water, low vacuum, kerosene (up to 60 C) ir, low vacuum, kerosene (up to 90 C *) Steam (up to 8 C *) ot water (up to 90 C *) ir, water, low vacuum, kerosene (up to 60 C) ir, low vacuum, kerosene (up to 90 C *) Steam (up to 8 C *) ot water (up to 90 C *) Refer to page 36 in the Introduction for details on the material combinations. Refer to the following page for details on the coil housing, other options and voltage, etc. <Example of model number> S-C00V : 35 (individual supply type / port pressurization) Type of thread: Rc Orifice: ø C Station no.: stations D ody/sealant combination: ody - brass, sealant - nitrile rubber E Coil housing: rommet lead wire F Manual override (locking): Selected Other options: lank Surge suppressor: Selected I Rated voltage: 00 VC 50/60z, 0 VC 60z Note on model no. selection *: Orders for only the masking plate and sub-plate are also available. Contact CKD for details. Note on C and D *: Consult with CKD about more than 0 stations manifold. *3: Leave blank for standard. owever, to select options in E to, indicate 0 for D. *: When, M or N is selected for D. *5: The ethylene propylene diene rubber seal combination (D P/R) cannot be used with air. (Compressed air contains oil, and ethylene propylene diene rubber is not oil-resistant. ) *6: When D is C, F, K, P, N or R, the coil housings E 6C, 6E, 6 and 6 cannot be selected.

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

SQUARE D INDUSTRIAL CONTROL PRODUCTS

SQUARE D INDUSTRIAL CONTROL PRODUCTS SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

NAMUR Mount Hygienic Valve

NAMUR Mount Hygienic Valve NF097-D NMUR Mount Hygienic Valve For Wash Down pplications Series VFN Features Engineered Plastic PPS Body (Polyphenylene Sulfide) provides high temperature and chemical/corrosion resistance for use in

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4 SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

SOLENOID VALVES 3-4 WAY

SOLENOID VALVES 3-4 WAY SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Sporlan V-Series Ruby Seat Solenoid Valves

Sporlan V-Series Ruby Seat Solenoid Valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Sporlan V-Series Ruby Seat Solenoid Valves RACE Catalogue 30-10-8 UK,

More information

Digital Flow Switch for Water 3 -color/2-screen display

Digital Flow Switch for Water 3 -color/2-screen display 3-color display New Digital Flow Switch for Water 3 -color/-screen display RoHS Main screen Sub screen Note 3) Main screen Sub screen Note 3) Instantaneous flow rate Set value Note ) ccumulated value Peak/ottom

More information

3/2-way pneumatic cartridge solenoid valve

3/2-way pneumatic cartridge solenoid valve 3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Shuttle valves SSR -2 Check valves, direct operated RK / R CS SPZE SPV

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8 * U S 4 Specifications escriptions Bore size mm Actuation Working fluid ax. working pressure Pa in. working pressure Pa Withstanding pressure Pa Ambient temperature Port size Stroke length Rubber cushioned

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 50 bar (5000 psi) and 7 L/min (60 USgpm) n Eaton rand ETON Screw-In Cartridge Valves E-VLSC-MC00-E November 009 -.

More information

type V46, solenoid or pneumatic operated

type V46, solenoid or pneumatic operated SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function

More information

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications Speed Controller with One-touch Fitting Stainless Steel Series Elbow Type/Universal Type Series -FG RoHS Stainless specifications for use in corrosive environments. Stainless steel used for metal parts.

More information

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double 4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor

More information

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

SOLENOID VALVE FOR REFRIGERATING SYSTEMS SOLENOID VALVE FOR REFRIGERATING SYSTEMS FROM UALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel uality Range of Products

More information

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711 A10VO Nominal size 18 see RD 92712 A10VO Nominal size 28...140 see RD 92711 The variable displacement axial piston pump A10VO in swashplate design was designed for hydrostatic drives in open circuits.

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to

More information

Stainless Steel Valves For the Sanitary Industries

Stainless Steel Valves For the Sanitary Industries www.swagelok.com Stainless Steel Valves For the Sanitary Industries Sanitary ball valves Manual and pneumatically actuated butterfly valves Disk and ball check valves ir blow check valves ir relief valves

More information

REGULATORS 175/153 Series

REGULATORS 175/153 Series 175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed

More information

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC 8mm Solenoid Valve Typical Applications Portable Equipment Blood Pressure Monitoring Wound Therapy Air and Oxygen Delivery Sensor Zeroing Product Specifications Mechanical Valve Type: 3-Way, Solenoid-actuated

More information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof

More information

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Section: MOYNO 500 PUMPS Page: 1 of 8 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Mechanical Seal Models Packing Gland Models MODELS DESIGN FEATURES

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel) OPTIONS: USE: AVAILABLE MODELS: Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel) DESCRIPTION The ADCA PRV47 pilot operated pressure reducing valves are designed for use on steam,

More information

Directional seated valves type VP 1

Directional seated valves type VP 1 Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual

More information

IOM SERIES 820-E/P Electro-Pneumatic Positioner

IOM SERIES 820-E/P Electro-Pneumatic Positioner FLUID CONTROL DIVISION Parker Hannifin Corporation 95 Edgewood Avenue New Britain, CT 06051 Telephone (860) 827-2300 IOM SERIES 820-E/P Electro-Pneumatic Positioner INSTALLATION, OPERATING & MAINTENANCE

More information

Electro-hydraulic pressure switches type DG

Electro-hydraulic pressure switches type DG Electro-hydraulic pressure switches type DG Pressure p max = 700 bar See also: For electronic pressure switches type DG 5 E see D 5440 E Analogous pressure transducer type DT 1 see D 5440 T Analogous pressure

More information

QLM and QLD Series Three-port Control Valves

QLM and QLD Series Three-port Control Valves Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 OD Tube 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8

More information

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES 01D351-GB FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES DOLOMIT FLOAT SWITCHES The DOLOMIT float switches find application in liquid level control in tanks and wells; they require connection

More information

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid 2- and 3-way Solenoid Valves for Gas and Liquid SV10: Vacuum to 3000 psig SV430: Vacuum to 3000 psig SV20: Vacuum to 6000 psig SV460: Vacuum to 6000 psig SV30: Vacuum to 3000 psig Circle Seal Controls

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation Air Catch Sensor Series For Workpiece Placement Confirmation No-contact sensor for confirming workpiece placement, with a configuration that is less affected by supply pressure change. Easy-to-set-up LED

More information

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS

More information

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 4057250/8 IM-P405-16 AB Issue 8 ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Operation

More information

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25

Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 Mechanical Valves Series VM Model Dimensions (mm) VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 VM100 Side ported 17 x 44 x 25 Bottom ported 17 x 44 x 30 VM200 25 x 40 x 52 One way roller

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS MANIFOLD ASSEMBLIES ONE-PIPE Compatible with most radiators on the market, this pre-assembled manifold for one-pipe radiator systems delivers balancing

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

Relative and absolute pressure switch type 529

Relative and absolute pressure switch type 529 Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20

More information

Series IDU/IDF. Refrigerated Air Dryer

Series IDU/IDF. Refrigerated Air Dryer Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...

More information

Typical Aluminum GFM Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.

More information

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation

More information