DESK PANEL DPA DPA: The compact design and mounting friendliness of the desk panel makes it suitable for placing under e.g. height adjustable desks.
|
|
- Edwin Holmes
- 7 years ago
- Views:
Transcription
1 DESK PANEL DPA DPA: Features: Control panel for up to 4 actuators in parallel Plastic housing with mounting holes (LINAK does not deliver the screws) Compatible with CBD1, CBD2 (not CBD2N), CBD3 and CBD m straight cable Colour: Charcoal grey RAL 716, buttons RAL 738 Adjustable panel The compact design and mounting friendliness of the desk panel makes it suitable for placing under e.g. height adjustable desks. The panel is compatible with all DESKLINE control boxes with micro-processor. Options: Customised front cover
2 Operation of the DPA in connection with DESKLINE systems (not CBD2N) The Desk Panel is used to operate the DESKLINE system. The two arrow buttons are used for parallel drive. Parallel drive ( ) The arrow buttons start parallel drive. The function is only actibated when holding the button down. Dimensions: Cable guidance Standard cable outlet cover 24 Ø Mounting guidelines: The DPA can be mounted on the desktop so that the keys are either facing upwards or outwards. Alternatively the DPA can be mounted flat under the desktop with the keys facing downwards. DPA Ordering example DPA K 6 Cables: Colour: Type 6 = Straight 158 mm 8 pole Modular Jack =DarkGreyRAL716 K = CBD1/CBD2E/CBD3/CBD4 Copyright LINAK 4.2. MA M D. Chapter Specifications subject to change without prior notice. It is the responsibility of the product user to determine the suitability of LINAK A/S products for a specific application. LINAK will at point of delivery replace/repair defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/repair.
3 DESKLIFT DL4 DL4: Features: Compact design where guide and actuator function are an integrated unit Max. thrust 8 N (per leg) Duty cycle: 1% or 6 min./hour or max. 2 min. at continuous use at full load Max. speed: 43 mm/sec. with CBD4 Built-in limit switches (not adjustable) Installation dimension 56 mm and stroke length 675 mm Dimension column: see drawing Low and uniform noise level Typical current consumption: 7,8 amp. at max. thrust (per DL4) Colour: black RAL 95 or grey RAL 96 aluminium white Hall sensor (enables parallel drive with CBD4) Ambient temperature: +5 C to +4 C Compatible with DESKLINE CBD4 control box Mounting bracket for crossbar in parallel system Double acting brake for increased self locking Bending moment: Max. 135 Nm static, max. 15 Nm dynamic The DESKPOWER DL4 is a new development specially made to extend the adjustment range of desks. LINAK fulfils even the strongest European standards that demand a range of adjustment from 6 mm up to 125 mm. The DL4 is a three part telescopic column with a similar movement of the middle profiles in a parallel system. DL4 is a compact lifting unit with a small installation dimension where the guide and actuator function are integrated. The whole actuating unit with the motor is placed in the column itself. This feature ensures an optimum freedom of design. Each DESKLIFT lifting unit is equipped with a motor. The DESKLIFT lifting column is part of a 2 parallel or a 3 parallel system. The parallel drive is obtained by means of special software in the CBD4 that also compensates for an uneven load on the desk. The control box CBD4 is designed with soft start/stop function.
4 DL4 dimensions: M6x (CENTER R6.4) 8±.2 R ±.3 87±.2 M6x (CENTER R6.4) 22± ±.3 28± ±.3 R ±.3 DETAIL B R DETAIL A R12 56±2 552±.5 3 SEE DETAIL B SEE DETAIL A 1235 STANDARD CABLE LENGTH = Approx. 5 mm STROKE = 675±2mm At a fully retracted length of 56 mm and a stroke length of 675 mm it is possible for a standard system to obtain an adjustment interval of the tabletop of e.g mm. Thus the desk can be used for sitting as well as standing work. Min. desk height Height of the DL4 in the lowest position Floor level Table top Absorbing material B Screw length Min.B+1mm Max.B+15mm Example of how to mount the DESKPOWER system Placement of a monitor directly above the leg may cause malfunction of the monitor. Magnets inside the motor may interrupt the picture on the monitor depending on the distance and type of monitor. If this is the case the problem may be solved by placing an iron plate/tube or another magnetic material, somewhat larger then the DL4, between the motor and the desktop.
5 DL4 Ordering example: DL4 B Installation dim Stroke Length Motor/gear type Option 56 mm 675 mm =Standard = Standard 43mm/s Colour Mounting bracket A = Grey (RAL 96) B = Black (RAL 95) = none 1 = Standard bracket Option Option Actuator type = Standard = Standard DESKPOWER Motor cables must be ordered separately: Motor cables: X Ordering number: 6171 (1 mm black motor cable) 6172 (2 mm black motor cable) (25 mm black motor cable) Bracket for travers: 5 R Ø Ordering number for crossbar brackets (box containing 1 pcs.): Technical specifications: Type Thrust Self-lock Duty Amp. at Transformer max. (N) at cycle full load type: 2P (N) pr. DL4 load in connection pr. DL4 (%) with CBD4 DL W DL4 8* W * 3P systems only 7N per DL4 Above measurements are made in connection with control box CBD4
6 and current curve (measured with control box CBD4): Load pr. leg DESKPOWER DL4 Typical values DESKPOWER DL4 Guaranteed values Parallel 2W DESKPOWER DL4 Typical values DESKPOWER DL4 Guaranteed values Parallel 3W DESKPOWER DL4 Typical values DESKPOWER DL4 Guaranteed values Parallel 3W Copyright LINAK 3.4. MA M C. Chapter Specifications subject to change without prior notice. It is the responsibility of the product user to determine the suitability of LINAK A/S products for a specific application. LINAK will at point of delivery replace/repair defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/repair.
7 CONTROL BOX CBD4 CBD4: Features: Mains voltage 12V AC, 23V AC, 5 6 Hz Compact high power toroidal transformer The control box is compatible with DL4, DL5, DL6 columns and DB4, DB5, DB6 built-in actuators for single or parallel drive Compatible with controls DPA or DP1K or DP1U for memory drive (3 positions) Low power consumption in stand-by mode due to use of toroidal transformer Duty cycle max. 1 % ~ 6 min. per hour or 2 min. at continuous use at full load Colour: black Exchangeable standard mains cable Protection against overload (EOP), by individual current limitation The control box is designed with a soft start/stop function. Hook for mains cable relief Approved according to EN and to UL 73 Auto detection of the number of units for parallel drive Auto detection of leg/unit type. The CBD4 control box is the newest and most sophisticated control box within the LINAK DESKLINE product range. The CBD4 ensures that the DESKLINE application has a very low and pleasant noise level and a constant speed level in the normal use area. The control box is compatible with the columns DL4, DL5, DL6 and the built-in actuators DB4, DB5, DB6. CBD4 ensures optimised parallel drive for 2, 3 or 4 legs in parallel or a smooth drive as a single leg control box.
8 Dimensions: B AC 5.5 Ø Mounting abbreviations: B = Control (DPA/DP1U) AC = Connection to the mains 1-3 = sockets for DB or DL lifting units Connection guidelines: Hook for cable relief Mains cable The cable can both be placed to the left or right on the DL4 Connection of the control and mains cable: The control ( DPA, DP1U or DP1K ) is to be connected on the same side of the control box as the lifting units. On the advanced CBD4 there are 2 DP ports, which both can be used. DPA DL/DB Please note that the control box must only be connected to the voltage stated on the label.
9 CBD4 Ordering example: CBD 4 P 2-9 Class: Mains cut-off: Mains voltage: Colour: 9 = Class 2 = Without mains cut-off =23V 1=12V 3 = 23V large transformer* 4 = 12V large transformer* -=Black Channels: 2 = 2 Channels 3 = 3 Channels 4 = 4 Channels Standard = Standard A = Advanced concept Standard Standard Standard Functionality: Name: 4 M = Single (will have 2 channels) C = Parallel H=4Parallel P=2Parallel Family: CBD * = Must always be chosen for 3 parallel systems and systems with DL5, DL6, DB5 and DB6 Mains cables must be ordered separately. Ordering number for the EU version Ordering number for the US version Mains cable: The plug on the new exchangeable mains cable is smaller than on earlier standard cables. Together with a cable relief hook on the CBD4 it ensures a stable cable connection. 32 +/- 5 Other mains cables (class II): Coiled EU version, black,.6 m Straight UK version, black, 3.2 m Straight AUS version, black, 3.2 m Straight EU version, grey, 3.2 m Coiled EU version, grey,.6 m
10 Specifications subject to change without prior notice. It is the responsibility of the product user to determine the suitability of LINAK A/S products for a specific application. LINAK will at point of delivery replace/repair defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/repair. Copyright LINAK 4.2. MA M F. Chapter 2.4.1
Operating Manual for Adjustable Height Tables. Contact us at 559.412.4541 or www.designformmfg.com 1
Operating Manual for Adjustable Height Tables Contact us at 559.412.4541 or www.designformmfg.com 1 Contents Safety Instructions... 3 General Operation... 4 DP 003 Control Panel... 6 Digital Control Panel...
More informationHow To Drive A Compact Serie 1
Electric lifting cylinder Compact Series Table of Contents Glossary... 2 Compact serie SR 1... 4 Dimension SR 1... 5 Compact Serie SR 1SP... 6 Dimension SR 1SP... 7 Compact Serie SR 5... 8 Dimension SR
More informationMODULAR JUNCTION BOX MJB WITH GATEWAY
PRODUCT DATA SHEET MODULAR JUNCTION BOX MJB WITH GATEWAY Features: Add on value for hospital & care application Compact and functional design which allows easy mounting 2 connections, Port 1 OpenBus connection
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationGeekDesk Max Instructions for Assembly & Use
GeekDesk Max Instructions for Assembly & Use Work Sitting OR Standing! With the touch of a button... Elevate Your Work Instructions release 1.5, 2012-08-09 WELCOME! Thank you for purchasing a GeekDesk!
More informationELS3 Electric Height Adjustment for sit-to-stand workplaces
ELS3 Electric Height Adjustment for sit-to-stand workplaces www.suspa.com Electric Height Adjustment for sit-to-stand workplaces Electric Lifting Column ELS3-650 With the Electrical Lifting Column ELS3
More informationPRODUCT DATA SHEET T-LIFT DESK
T-LIFT DESK The height-adjustable desk allows you to alternate at work between sitting and standing. Formally minimalist; visually and technically based on the T-Platform. To be used for desk-sharing applications
More informationFocus on Building Louvres. Sun shading & comfort ventilation. www.linak.com/techline
Focus on Building Louvres Sun shading & comfort ventilation www.linak.com/techline Improve energy efficiency and indoor climate with building louvres There is an increasing focus on energy conservation
More information15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationQuick Guide for. BusLink
Quick Guide for BusLink BusLink Configuration Software Actuators with IC - Integrated Controllers from LINAK can be configured via BusLink software. BusLink is a software tool to set different parameters
More informationT-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5. www.thomsonlinear.com
T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5 www.thomsonlinear.com Version History Edition Number Edition Date Reason for Revision 1 2004 First edition
More informationCOMPACT eco For firmware version 1.8 Rev0
User manual Control Unit for an Electric Height-Adjustable Desk COMPACT eco For firmware version 1.8 Rev0 Subject to change without notice. Errors and omissions excepted. LOGICDATA cannot accept responsibility
More informationHow To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationMAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating
MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationOperating instructions IV / 2007
General Operating instructions IV / 2007 Contents General Installation Application and function Application and function... 2 Safety information... 2 Design and dimensions... 3 Wiring diagram... 3 Installation
More informationProduct Information Sheet UH28CS-12kV Hi Pot Tester
Product Information Sheet UH28CS-12kV ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet:
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationPhysical Specifications (Custom design available.)
Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given
More informationUPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video
UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video http://bit.ly/9ywwh! CAUTION MAKE SURE NO OBSTACLES ARE IN THE DESK S PATH AND ALL
More informationELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
More informationMPPM1606 MPPM2508 MPPM3210
MPPM 2-jaw parallel self-centering electric gripper Plug & play user friendly gripper. No electricity consumption when gripper is engaged. No programming required. Gripper retention guaranteed in event
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationMPLM1630 MPLM2535 MPLM3240
MPLM Self-centering 2-jaw electric parallel gripper with long stroke Plug & play user friendly gripper. No electricity consumption when gripper is engaged. No programming required. Gripper retention guaranteed
More informationEmergency Voice Communication Systems EVCS Network 8 Data Sheet
Emergency Voice Communication Systems EVCS Network 8 Data Sheet The Emergency Voice Communications System (EVCS) Network 8 is for use as a Fire Telephone system, Disabled Refuge Call system or as a combined
More informationINSTRUCTIONS FOR USE Pro-Ject Tube Box S
INSTRUCTIS FOR USE Pro-Ject Tube Box S Dear music lover, thank you for purchasing a PRO-JECT AUDIO phono amplifier. In order to achieve maximum performance and reliability you should study these instructions
More informationElectro-Pneumatic Bus Door Control Mechanism
Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with
More informationINSTRUCTIONS FOR USE Pro-Ject Phono Box II USB
INSTRUCTIONS FOR USE Pro-Ject Phono Box II USB Dear music lover, thank you for purchasing a PRO-JECT AUDIO phono amplifier. In order to achieve maximum performance and reliability you should study these
More informationUser Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
More information225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
More informationFCC COMPLIANCE STATEMENT FOR AMERICAN USERS
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationRack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances
This set of instructions applies to racking and rail kit installation for 6XX and above. The Rack Mounting Instructions section below provides information on installing the SC825 chassis into a rack unit
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION Models No. 2012NB Description 304mm (12") Automatic Thickness Planer CONCEPTION AND MAIN APPLICATIONS * Compact and light weight (27 Kg./59 lbs) automatic thickness planer for easier
More informationUser Manual. Ology. Original user manual
User Manual Ology Original user manual BA_Ology _EN_02_2014 www.steelcase-village.de Table of contents 1 General instructions 1.1 About the Ology product series....................................... 3
More informationOZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
More informationACTUATOR LA37 PRODUCT DATA SHEET
PRODUCT DATA SHEET ACTUATOR LA37 Features: 12, 24 V DC Permanent magnetic motor Thrust from 10,000N - 15,000N Static holding force up to 70 kn in push and pull Dynamic wind stress forces 15 kn push/pull
More informationUno 102. Product Description. Instruction Guide
Uno 102 Instruction Guide English 7EN150104-04 2013-08-22 Applies to the following models: Uno 102 EE Prod. No. 2010004 Product Description Uno 102 is a mobile lift with electric raising and lowering of
More informationInForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley
Selection Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley Basic mobile unit Basic mobile with vertical profiles Installation options Functional shelf, low Functional shelf, inclinable
More information60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
More informationFEATURES. ! Sealing to IP68 (fully waterproof) Infra-red optical navigation technology
ERGONOMICAL IP68 TRACKBALL UNIT Waterproof trackball & scroll wheel IP68 50mm The Series desktop trackball is an extremely high specification device that incorporates the latest IP68 technology. The trackball
More informationinstallation guide ACTIV-1
installation guide ACTIV- Base foot. Leg x columns - right & left Motor unit. Work surface supporting bracket (Cantilever) x Control. box Base foot x Handset 4. Phase Motor unit Materials and Tools Hardware
More informationLIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
More information4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
More informationZMR 80 STEREO MODULAR ZONER USERS MANUAL
ZMR 80 STEREO MODULAR ZONER USERS MANUAL Lime Technologies http://limetechnologies.co.uk Tel: 08712 233127 ZMR80 Stereo Modular Zoner Mixer Introduction The modular construction of the ZMR80 allows it
More informationOperating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions
More informationDENTAL CHAIR AND UNIT SP- CIELA IMPORTANT
DENTAL CHAIR AND UNIT SP- CIELA OPERATING MANUAL IMPORTANT This manual provides operating instruction for BELMONT SP-CIELA. The instructions contained in this booklet should be thoroughly read and understood
More informationTECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
More information4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
More informationgarage door operators
garage door operators duo vision separate control unit with integrated interior pushbutton Optional designer control housings other control unit housings with different finishes (ask about further designs)
More informationWespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE
Wespot SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE EN This manual is published by OPTEX, without any warranty. Improvements and changes to this manual necessitated by typographical errors, inaccuracies
More informationACTUATOR LA37 PRODUCT DATA SHEET
PRODUCT DATA SHEET ACTUATOR LA37 Features: 12, 24 V DC Permanent magnetic motor Thrust from 10,000N - 15,000N Static holding force up to 70 kn in push and pull Dynamic wind stress forces 15 kn push/pull
More informationWireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationfocus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V01.3-2014-7
focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V01.3-2014-7 Thank you for purchasing our product. Please read this manual carefully before operation your set and retain it for future reference. FT55-P10
More informationED 100LE ED 250LE. Low energy swing door operators
ED LE ED 250LE Low energy swing door operators ED LE & ED 250LE LOW ENERGY SWING DOOR OPERATORS LOW ENERGY SWING DOOR OPERATORS Automatic doors provide a means of opening and closing doors without the
More informationLIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
More informationIMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
More informationFredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.
Conveyor Solutions Whatever your logistic needs, we can offer a conveyor solution. Our flexible systems primary and secondary packaging for single and multi packages, can transport your goods from one
More informationCORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
More informationSWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
More informationMAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions
MAKING MODERN LIVING POSSIBLE living connect Installation and User Guide Danfoss Heating Solutions 2 living connect Thank you for buying a Danfoss product Danfoss Heating Solutions 3 Contents 1. System
More informationAdvantages Elegant and slim design Optimised ergonomics Simple operation No coupling stroke required Working in ergonomically optimum height
Lifting Module Basic Max. lifting force 1,000 N, stroke from to 600 mm, manual-hydraulic version Issue 9-11 E M 4.101 M 4.101 dvantages Elegant and slim design Optimised ergonomics Simple operation No
More informationProduct Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
More informationAnalogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
More informationTechnical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
More informationT5000 T000 LCD Digital Fan Coil Thermostat
T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,
More informationPD 100A. Printing data system
PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep
More informationVIDEO DOOR PHONE SYSTEM
ENGLISH VIDEO DOOR PHONE SYSTEM USER MANUAL Manual covers IH-692 Master and IH-692 Slave Monitors PRECAUTIONS BEFORE INSTALLATION Connect this unit ONLY to other compatible units. Do not connect it to
More informationI. Introduction 02. Specifications 02 Accessories 02 Features 03. II. Installation Instructions 06
EN I. Introduction 02 Specifications 02 Accessories 02 Features 03 II. Installation Instructions 06 1. Installation of the motherboard 06 2. Installation of the power 07 supply 3. Installation of external
More informationCOLOR VIDEO DOOR PHONE CDV-71BE/D
COLOR VIDEO DOOR PHONE CDV-71BE/D 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed
More informationMANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.
MX MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest
More informationSERVOMECH Linear Actuators
. SERVOMECH Linear actuators SERVOMECH mechanical linear actuators are motorised mechanical cylinders able to transform the rotary motion of a motor into the linear motion of a push rod. They are designed
More informationVideo Splitter VS-104 / VS-108 User's Manual
Video Splitter VS-104 / VS-108 User's Manual VS-1048 07-11-02 Page 1 of 6 Packing Checklist 1 VS-104/VS-108 Video Splitter 1 DC 9V 300mA (min.) Power Adapter 1 User's Manual Please read this manual thoroughly
More informationMicro HDMI to VGA with Audio Adapter. Quick Installation Guide. Introduction. Key Features and Benefits. System Requirements.
Introduction Micro HDMI to VGA with Audio Adapter Quick Installation Guide The Micro HDMI to VGA with Audio Adapter converts HDMI signals from a portable device, such as a laptop, smart phone or tablet
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationVX 2400 Dimmer User's Manual
TM VX 2400 Dimmer User's Manual 21-2119C Manual Revision 1.01 Software Version 1.0 10 March 1994 Table of Contents 1. General Description...3 1.1. Standard Features:...3 2. Installing Options...4 2.1.
More informationHousing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
More informationSECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF)
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF) PART 1-GENERAL 1.01 RELATED WORK SPECIFIED IN OTHER SECTIONS A. Electrical connections see electrical specifications. 1.02 SUBMITTALS A.
More informationS t a r T r a d i n g. M e i j n e r s w i j k 1 3 B 6 8 4 1 H A A r n h e m + 3 1 ( 0 ) 2 6 3 3 9 1 8 4 9 + 3 1 ( 0 ) 2 6 3 3 9 1 6 5 8
S t a r T r a d i n g M e i j n e r s w i j k 1 3 B 6 8 4 1 H A A r n h e m + 3 1 ( 0 ) 2 6 3 3 9 1 8 4 9 + 3 1 ( 0 ) 2 6 3 3 9 1 6 5 8 www.startrading.nl info@startrading.nl GALAXY 1-4 Dual motor actuator
More informationStroom voor elke toepassing
ELECTRICITY: ALWAYS & EVERYWHERE With VICTRON Phoenix MultiPlus and a HONDA Generator An intelligent combination with endless possibilities! Electrical appliances that increase on board comfort, such as
More informationAU-110 racking guide NBXPN: 023
AU-110 racking guide NBXPN: 023 1. Overview NIMBOXX AU-110 Rack Installation This guide provides setup instructions for installing your NIMBOXX AU-110 in a rack. Following these steps in the order given
More informationABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
More informationBeoLab 1. User s guide
BeoLab 1 User s guide Legal notice: CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing
More informationPCB Relay. LED indicator G2R-1A3-SN G2R-13-SN --- --- contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND --- ---
PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE045 (VDE approval: C2 insulation grade), UL8, CSA22.2, SEV, SEMKO. Meets VDE0700 requirements for household products
More informationSEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
More informationwww.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
More informationH45 LED - Direct and indirect pendant
RAL 01 10 00 IP 20 230V 50/60Hz Specifications Direct and indirect light pendant linear luminaire. Aluminium profile. Diffusers in frosted polycarbonate profile. Driver included. Supplied with clear base,
More informationWind Sensor W-RS485 with RS485 Interface
Wind Sensor W-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93
More informationCAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 4 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified service
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
More informationU LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC
Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board
More informationUser Manual. Video Doorphone CDV-1020AQ
User Manual Video Doorphone CDV-1020AQ 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133 Web site : www.commax.com
More informationClearView+ User Manual
ClearView+ ClearView+ User Manual Rev. 2.0, December 2005 All rights, in particular the rights of reproduction as well as translation, are reserved. No parts of this manual may be copied, in any form whatsoever,
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More information