TABLE OF CONTENTS COMPANY INFORMATION HOUSING MODELS CONNECTION DETAILS ENERGY STAR PHOTOS SPECIFICATIONS COMPANY BROCHURES
|
|
- Brianne Shepherd
- 7 years ago
- Views:
Transcription
1 PANELIZED HOUSING 4650 Lyons Technology Parkway, Coconut Creek, Florida Fax info@elitealuminum.com
2
3 TABLE OF CONTENTS 1) 2) 3) 4) 5) 6) 7) COMPANY INFORMATION HOUSING MODELS CONNECTION DETAILS ENERGY STAR PHOTOS SPECIFICATIONS COMPANY BROCHURES
4
5 COMPANY INFORMATION 1) 2) 3) 4) 5) COMPANY HISTORY PRODUCTS MARKETS PRODUCT APPROVALS RECENT PROJECTS
6
7 COMPANY HISTORY Elite Aluminum Corporation, was founded in 1981, and is a leading manufacturer of structural insulated panels and enclosure systems for the commercial and residential construction industries. During our 30 years in business we have built our reputation on engineering new and innovative solutions that meet the needs of our customers, while investing in research and development to find new and better technologies that advance the industry as a whole. Elite s primary manufacturing facility is over 200,000 sq. ft. in Coconut Creek, Florida, and has the capacity to produce over 100,000 sq. ft. of panelized building products per day. PRODUCTS Elite s construction system utilizes sandwich-type structural panels composed of two outer facings of aluminum, wood, gypsum, non-asbestos fiber, reinforced cement board or other material, laminated to a core of expanded polystyrene (the same product used in freezer walls, refrigerators, coolers, etc.) 99.9% of its mass is closed air cells that cannot absorb moisture as fiber glass and paper honeycomb cores do. Therefore the core will not deteriorate from moisture, is lightweight, waterproof, insect proof, and virtually soundproof. Our products are being used for residential housing, telecommunication support buildings, office buildings, government housing and military quarters, schools and classrooms, hospitals and clinics, kiosks and in-plant offices. In early 2009, our engineering and design team started the research and development for a revolutionary product, which we now refer to as FORTS, or Fold-Out Rigid Temporary Shelters. Elite Aluminum Corporation is a leading manufacturer of the most innovative shelters on the market. We are currently serving markets in the emergency, governmental, commercial, and residential sectors. Our unique foldout system allows for up to six FORTS to be loaded on a flatbed trailer or container. Once delivered to the location FORTS can be deployed in less than 10 minutes, using 3 unskilled laborers, and a few simple hand-tools. MARKETS Elite products have been installed across the US and around the world to the residential, commercial, and governmental sectors. Our structures are adaptable to virtually any climate and are currently in use in places as diverse as the tropics of southern Africa and the steppes of Russia. We have sold our products throughout the world, including Africa, the Caribbean, South America, Europe, the Middle East, and the Philippines. Wherever there is a need for pre-engineered, pre-cut building components, we can ship by land, sea or air.
8 PRODUCT CODE APPROVALS The structural insulated building components produced by Elite carry the following code approvals: 1. International Building Code (IBC) 2. Uniform Building Code (UBC) 3. South Florida Building Code 4. Standard Building Code 5. International Residential Code NER International One & Two Family Dwelling Code NER National Building Code 8. Underwriters Lab. UL 1715 UBC 17-5 It is only through stringent and constant supervision of Elite s quality control and end less testing can a Manufacturer main these code approvals. RECENT PROJECTS Africa Philippines - Angola Housing Project Manufactured houses for Chevron Oil Company - Sierra Leone Housing Project & Commercial Offices and Factories - Nigeria Mass Housing Project Blue Water Structural Housing Project - Commercial Communications Buildings Radio Communications of the Philippines (RCPI) South America - Argentina/Chile Buildings Commercial Communications Buildings for MovieStar Inc. - Colombia Housing Project Manufactured houses for Pacific Rubiales Oil Company
9 HOUSING MODELS 1) 2) 3) MODEL 62 MODEL 72 MODEL 98
10
11
12
13
14
15
16
17 CONNECTION DETAILS 1) 2) 3) 4) FOUNDATION DETAILS ROOF & CONNECTION DETAILS SECTION DETAILS PANEL DETAILS
18 x x x x x x OF x
19 OF
20 OF
21 OF
22
23
24
25
26
27 TECHNICAL INFORMATION 1) 2) 3) PRODUCT WARRANTY HARDIE BUILDING PRODUCTS ENERGY STAR
28
29
30
31
32
33 PHOTOGRAPHS 1) 2) EXISTING PROJECTS TRAINING HOUSE AT ELITE FACILITY
34
35
36
37 SPECIFICATIONS 1) 2) 3) 4) HOUSING QUOTES ELITE ROOF SYSTEM ELITE WALL PANELS PANEL SPAN TABLES
38 Elite 62 Housing Quotation Elite Aluminum Corporation will provide materials for the shell construction of a 62 square meter home (672 Square feet 24 x 28 ). Materials included will be: 1. Exterior 4 ¼ wall panels comprised of 5/16 Hardie cement board laminated to a expanded polystyrene foam core with electrical chase (electrical wire not included & accessories not included). 2. All roof panels to be 4 aluminum panels with polystyrene foam core with 5) fan beam panels encapsulated with drip edge fascia, with ridge beam and columns to support gable roof. 3. Splines and connectors for wall panels consist of 4 wide 18 gauge steel along with 20 gauge steel track for top and bottom of wall panels. 4. Sealants and fasteners for roof and walls to be included. 5. Aluminum windows are a 3500 series single-hung, with 1/8 temp glass 6) 35 1/4 x 51 ¼ & 2) 27 1/4 x 27 1/4. 6. Two exterior steel doors for front & side entry 36 x 80 complete with hardware and trim. 7. Elastomeric paint and primer to coat exterior wall panels supplied (color to be determined). Exterior Shell Only (non-pre-cut) Please Call For Pricing
39 Elite 72 Housing Quotation Elite Aluminum Corporation will provide materials for the shell construction of a 72 square meter home (768 Square feet 24 x 32 ). Materials included will be: 1. Exterior 4 ¼ wall panels comprised of 5/16 Hardie cement board laminated to a expanded polystyrene foam core with electrical chase (electrical wire not included & accessories not included). 2. All roof panels to be 4 aluminum panels with polystyrene foam core with 5) fan beam panels encapsulated with drip edge fascia, with ridge beam and columns to support gable roof. 3. Splines and connectors for wall panels consist of 4 wide 18 gauge steel along with 20 gauge steel track for top and bottom of wall panels. 4. Sealants and fasteners for roof and walls to be included. 5. Aluminum windows are a 3500 series single-hung, with 1/8 temp glass 4) 35 1/4 x 51 ¼ & 2) 27 1/4 x 27 1/4. 6. Two exterior steel doors for front & side entry 36 x 80 complete with hardware and trim. 7. Elastomeric paint and primer to coat exterior wall panels supplied (color to be determined). Exterior Shell Only (non-pre-cut) Please Call For Pricing
40 Elite 98 Housing Quotation Elite Aluminum Corporation will provide materials for the shell construction of a 98 square meter home (1056 Square feet 24 x 44 ). Materials included will be: 1. Exterior 4 ¼ wall panels comprised of 5/16 Hardie cement board laminated to a expanded polystyrene foam core with electrical chase (electrical wire not included & accessories not included). 2. All roof panels to be 4 aluminum panels with polystyrene foam core with 5) fan beam panels encapsulated with drip edge fascia, with ridge beam and columns to support gable roof. 3. Splines and connectors for wall panels consist of 4 wide 18 gauge steel along with 20 gauge steel track for top and bottom of wall panels. 4. Sealants and fasteners for roof and walls to be included. 5. Aluminum windows are a 3500 series single-hung, with 1/8 temp glass 6) 35 1/4 x 51 ¼ & 2) 27 1/4 x 27 1/4. 6. Two exterior steel doors for front & side entry 36 x 80 complete with hardware and trim. 7. Elastomeric paint and primer to coat exterior wall panels supplied (color to be determined). Exterior Shell Only (non-pre-cut) Please Call For Pricing
41 I. Panel Weight ELITE HARDIE BOARD WALL PANELS lbs per square foot vs. concrete block at 14lbs per square II. Fire 1. Panel facings are non-flammable III. Sound transmission 1. Sound transmission of Transfer loss of 52.1db at Hz frequency of 5000 IV. R-Value 1. R Thermal resistance of 4 ¼ thick wall system V. Moisture 1. Panel facings of non-asbestos fiber cement approved by fema as a class 5 moisture resistance material 2. Approved by the national flood insurance program as a material highly resistance to flood waters 3. Approved by ICC-ES as a water resistant moisture barrier VI. Hazardous ingredients 1. All ingredients are not hazardous for shipping purposes
42 ELITE ALUMINUM INSULATED ROOF SYSTEM I. Approvals (support documents available upon request) 1. ICC-ESR 1599 National Approval with all major building codes International Building Code International Residential Code New York State Building Code Florida Building Code- 13 product approvals 6. Approved for high velocity hurricane zone (hvhz) 7. State of California- 5 approvals on roof and wall system II. FIRE TESTING- ROOF SYSTEMS (SUPPORT DOCUMENTS AVAILABLE UPON REQUEST) 1. Class A flame spread 2. Class B includes burn through and burning brand 3. UL 1715 Classification 4. UBC 26-3 III. ENERGY (SUPPORT DOCUMENTS AVAILABLE UPON REQUEST) 1. R-Values to Energy Star Rated 3. Green Certified for recycled content
43
44 COMPANY BROCHURES 1) 2) 3) HOUSING FORTS FOLD-OUT SHELTER ELITE 2000 STOREFRONT
45
46
47
48
49
50
51
52
53
54
55
56
Built to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
More informationfirst look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
More informationTechPractices: Home Front Homes:
TechPractices: Home Front Homes: PATH's Technologies in Practice are large scale housing projects throughout the U.S. where innovative technologies are being installed and used. Information is presented
More informationCHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
More informationROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
More informationCONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
More informationSECTION 07 21 16 - PRE-ENGINEERED BUILDING BLANKET INSULATION
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
More informationDENVER MODEL 30 X 30 SPECIFICATIONS
DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch
More informationRe-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY
Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded
More informationEXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
More informationB. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010.
SECTION 15190 HVAC INSULATION PART ONE - GENERAL PART 1 - GENERAL 1.01 DESCRIPTION A. All work specified in this Section is subject to the provisions of Section 15010. B. All insulation products shall
More informationSTAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationSTANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS
ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the
More informationWall and Ceiling Products Moisture and Corrosion Proof Panels
Wall and Ceiling Products Moisture and Corrosion Proof Panels P3000 Beaded Panel (Top) P1300 Flat Panel (Bottom) Concession Stand Car Wash Extrutech Plastics Inc., provides high-quality, moisture and chemical-resistant
More informationSECTION 07550 - MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.
SECTION 07550 - PART I GENERAL 1.01 SECTION INCLUDES A. Vapor barrier (base ply); cover board at existing roof deck. B. Roof insulation at new roof deck. C. Modified bitumen membrane. D. Fluid applied
More informationSubstantial Improvement/Damage (FEMA 50% Rule) Frequently Asked Questions and Information
SUBSTANTIAL IMPROVEMENT/DAMAGE WORKSHEET (FEMA 50% RULE) South County: Development Services North County: Development Services 4000 Tamiami Trail S. Room 122 1001 Sarasota Center Blvd Venice, Florida 34293-5076
More informationBafl-Sorb Sound Absorbing Ceiling Baffles
Bafl-Sorb Sound Absorbing Ceiling Baffles INC offers a complete line of Sound Absorbing Ceiling Baffles to compliment any environment. Our ceiling baffles are among the most cost-effective method of adding
More informationSPREFIX SPRAY INSULATION _ in the marine market.
SPREFIX SPRAY INSULATION _ in the marine market. A self-adhesive glass or stone wool, sprayed directly onto surface.. Easily applied to wood, steel, plastic or other surfaces without any mechanical fasteners
More information- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner
The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional
More informationGridstone Gypsum Ceiling Panels
Gold Bond brand 09 29 00/NGC Gridstone Gypsum Ceiling Panels Helping You Build Better With High-Quality Products And Resources Founded in 1925, National Gypsum is one of the world s largest producers of
More informationEnvelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
More informationINNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT. awipanels.com From freezing, sub-zero temperatures to Contents dry heat or high humidity, Mother Nature continually tests the limits of building envelopes. That's
More informationResidential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
More information16 2 10.3 Materials and Colors
16 2 10.3 Materials and Colors To create a harmonious and coherent image for each development, building designs shall pay close attention to choice of materials and colors. Building construction shall
More informationMovie star Brad Pitt helps Make It Right rebuild the Lower Ninth Ward with affordable LEED Platinum homes
Make It Right Movie star Brad Pitt helps Make It Right rebuild the Lower Ninth Ward with affordable LEED Platinum homes Few can forget the horrific images from Hurricane Katrina. In 2005, the hurricane
More informationPANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
More informationCommercial And Industrial Steel Buildings
Commercial And Industrial Steel Buildings Arco Building Systems, Inc. Since 1979 Arco has been providing the highest quality steel buildings to contractors and owners throughout the United States. Leadership
More informationCERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:
STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS - RE-ROOF CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name: CALIFORNIA ENERGY COMMISSION CF-1R-ALT-01-E (Page 1 of 2) Date Prepared: A.
More informationMeeting the Fire Code with Continuous Foam Plastic Insulation
Dow Building Solutions Meeting the Fire Code with Continuous Foam Plastic Insulation The 2012 International Building Code (IBC) specifies the fire tests that must be passed if a foam plastic material is
More informationCHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS
TITLE: STANDARDS FOR NEW ROOFING CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS Responsible Organization: Office of Facilities Planning Instructions: This Manual supersedes
More informationThe Case for Cross Laminated Timber: Part 2
Learning Objectives The Case for Cross Laminated Timber: Part 2 Opportunities and Challenges for a New Class of Timber Product 1. Review answers to common questions regarding the design and construction
More informationINC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications
INC Flexi-Sorb Noise Control Curtain System Versatile Flexible Easy To Install Durable Good Noise Reduction Economical Our Flexi-Sorb noise control curtain product line consists of flexible, durable acoustical
More informationThe better way to build TM. Installation Manual. EXTERIOR WALL SIPs
The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationRoof Insulation Building. Energy. Environment friendly e-library
Roof Insulation Building Codes & Energy Efficiency Environment friendly e-library Building Code Driver Buildings consumer almost 50% of all energy. Experts believe that a 30% increase in building efficiency
More informationMASTERFORMAT SPECIFICATION
Insulspan, Incorporated 9012 East US 223 Blissfield, MI, USA 49228-0026 Phone: 800.726.3510 Insulspan Division of Plasti-Fab Ltd. 600 Chester Road Deltas, BC, Canada V3M 5Y3 Phone: 866.848.8855 www.insulspan.com
More informationICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.
ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-900* Reissued March, 20 This report is subject to renewal in one year. A Subsidiary of the International Code Council DIVISION:
More informationInsulation R-Value Comparisons
Insulation R-Value Comparisons American Ingenuity s component panels for the 22 48 domes contains seven inch thick rigid Expanded Polystyrene (E.P.S.) insulation which has an R value of 28. American Ingenuity
More informationDIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC
0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND
More informationCOLORADO MODEL. 35 x 65 SPECIFICATIONS
COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square
More informationDevelopment Services City of Lawrence, KS
Development Services City of Lawrence, KS Building Planning Table R301.2 (1) Climatic & Geographic Design Criteria Building Planning The design criteria for wind speed increased from 90 MPH to 115 MPH.
More informationCOMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
More informationmetal Duil~ing manufacturers Association
metal Duil~ing manufacturers Association ApplicatiDns metal Building Systems Conventional Buildings Retrofit Roofing Projects l~e Perfect Cover.One of the most important technological advances in building
More informationImpact-Resistant Windows and Sliding Glass Doors
Impact-Resistant Windows and Sliding Glass Doors Make Your Home A SafeHarbor. SafeHarbor Impact-Resistant Windows and Sliding Glass Doors are designed to look like traditional windows and doors, but they
More informationSAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT
SAMPLE SCHEDULE OF S 1.00 General Conditions 1.01 Project Management 1.02 General Superintendent 1.03 Superintendents 1.04 Safety Engineer 1.05 Scheduling 1.06 Field Engineering 1.07 Bonds 1.08 Trailer
More informationProven roofing SyStemS
Proven Roofing Systems Above all. Roofing challenges are never over our heads At GenFlex, we live to tackle and solve the toughest challenges in roofing. The result is a full line of proven, durable roofing
More informationSECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
More information09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS
09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS PDS SE-160 01-2006 1. PRODUCT NAME SE-160 Clear Surface Coating (water-based copolymer) Specialty Elastomeric Topcoat 2. MANUFACTURER
More informationSECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
More informationThe Last Roof Your Home Will Ever Need
Allmet Stone-Coated Metal Roofing Systems I N T E R N A T I O N A L The Last Roof Your Home Will Ever Need Choose Strength. Choose Allmet. Why Allmet? FIRE Allmet s patented interlocking fastening system
More informationULTIMATE GUIDE BE PREPARED FOR YOUR UPCOMING PROJECT
ULTIMATE GUIDE BE PREPARED FOR YOUR UPCOMING PROJECT What are Backer Boards and Underlayments? Backer boards and underlayments are used on interior walls, floors and countertops to provide a uniform surface
More informationSTANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
More informationMETAL BUILDING SYSTEMS
BUILDING SYSTEMS The Brand of Choice METAL BUILDING SYSTEMS www.nucorbuildingsystems.com Building Systems The Brand of Choice Nucor Building Systems, a division of Nucor Corporation, is one of the most
More informationSELF-STORAGE BUILDINGS
SELF-STORAGE BUILDINGS QUALITY and RELIABILITY The self-storage business has grown into a multi-billion dollar industry. Current businesses are expanding and new companies are starting up every day. The
More informationSECTION 3 ONM & J STRUCTURAL ANALYSIS
Historic Boynton Beach High School Existing Building Assessment City of Boynton Beach February 10, 2011 SECTION 3 ONM & J STRUCTURAL ANALYSIS STRUCTURAL ENGINEERS SPECIAL INSPECTORS STRUCTURAL CONDITION
More informationST. MONICA FOOD PANTRY HOUSTON, TEXAS
PROJECT MANUAL FOR ST. MONICA FOOD PANTRY HOUSTON, TEXAS OWNER: ST. MONICA CATHOLIC CHURCH 8421 W. MONTGOMERY ROAD HOUSTON, TEXAS 77088 ARCHITECT: C SIX ARCHITECTURE, LLC 4606 F.M. 1960 WEST, STE 400 HOUSTON,
More informationRefrigeration Installation 101
Refrigeration Installation 101 Hundreds of Installations Refrigerated Cases 2 Compressor Racks 3 Condensing Units 4 Walk-in Boxes 5 Some were done very well 6 Some had some issues... 7 8 Some seemingly
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.
More informationAdding value to the finest homes in Virginia for 52 years! years
52 years Family Owned and Trusted! Adding value to the finest homes in Virginia for 52 years! James Hardie Fiber Cement Siding Insulated Vinyl Windows Insulated Vinyl Siding Vinyl Railings, Columns, Entry
More informationFOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
More informationThe Foundation Group SSIPS vs Concrete Block and Wood Framing
www.thefoundationgroup.us RoryHiller@gmail.com The Foundation Group SSIPS vs Concrete Block and Wood Framing The creation of concrete building systems, such as concrete block, when created was a fair choice.
More informationNRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry
More informationROXUL Board Insulation Section 07 21 13 Master Guide Specification (CAVITYROCK ) Page 1 April 2016
Master Guide Specification (CAVITYROCK ) Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROXUL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual.
More informationSECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationThe Cabin Shell Series
The Columbia 816 sq ft 1 Story 2 Bedrooms 1 Bathroom Effective June 2014 The Columbia EXAMPLE FINISH STANDARD FLOORPLAN Options Pricing Description Retail UoM Deck Wood Floor - Exterior 2x6 Pressure Treated
More informationWind Mitigation Inspection
tpatrick@ispects.me Tampa Bay Area: SW & Central Florida: (813) 368-6407 (239) 896-3986 Wind Mitigation Inspection VonHaase, Dale 4585 Bowen Bayou Road Sanibel, FL 33957 5/6/2013 Note to Policyholder:
More informationRenovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
More informationVOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10
VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 SECTION B1: PREPARATION GUIDE B1.1 INTRODUCTION... B1-1
More informationfoot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationUnderwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
More informationFrequently Asked Questions LP SmartSide Siding, Trim, and Soffit
Frequently Asked Questions LP SmartSide Siding, Trim, and Soffit 1. Can soffit be used for siding? a. No. The soffit is designed specifically for a protected soffit application whereas siding is designed
More informationELIGIBLE REPAIR PROJECT PARAMETERS
THE DISTRICT MUNICIPALITY OF MUSKOKA ONTARIO RENOVATES PROGRAM FOR HOMEOWNERS ELIGIBLE REPAIR PROJECT PARAMETERS 1. To have your project considered and payment processed, all projects requiring a Building
More informationRoof insulations must perform the basic function of helping to control fluctuations in building interior temperature
Thermal Values Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature relative to changing exterior temperatures. By reducing interior temperature
More informationTEST REPORT. Rendered to: INTEX MILLWORK SOLUTIONS, LLC. For: Rigid Cellular PVC Guardrail System Hampton RS40
TEST REPORT Rendered to: INTEX MILLWORK SOLUTIONS, LLC For: Rigid Cellular PVC Guardrail System Hampton RS40 Report No: Report Date: 07/26/13 130 Derry Court York, PA 17406-8405 phone: 717-764-7700 fax:
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More informationRemovable Insulation Blankets from A to Z
Removable Insulation Blankets from A to Z At first glance, making up a removable insulation blanket seems somewhat simple take some insulation, put some mesh on one side, a cover on the other, sew them
More information609 West Rock Road, Radford,VA 24141 540-633-5000 / (fax) 540-731-3712 RECOMMENDED ATTACHMENTS & CONNECTION DETAILS
609 West Rock Road, Radford,VA 24141 540-633-5000 / (fax) 540-731-3712 RECOMMENDED ATTACHMENTS & CONNECTION DETAILS INDEX OF DRAWINGS SECTION A: A-1 = METAL TRACK TO PANEL ATTACHMENT A-2 = WOOD PLATE TO
More informationLogisticsCentre IV Distribution Center
KCI Intermodal BusinessCentre LogisticsCentre IV LogisticsCentre IV Distribution Center Modern Warehouse/Distribution Space Ranging From 108,000± SF to 432,000± SF 10221 NW Transcon Drive 112th Street
More information*Aggregate Material Index of the 9 most commonly used building materials Residential
CLAIMS BULLETIN CLAIMS DATA UPDATE BULLETIN-USDC Symbility Solutions is pleased to provide you with an overview of updates in the 1 st Quarter 2015 release of CoreLogic Insurance Solutions Partial Loss
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationD Sample Notices to Property Owners, Sample Affidavits, and Other Material
D Sample Notices to Property Owners, Sample Affidavits, and Other Material These samples are offered to illustrate specific points in the Desk Reference. States and communities should examine them carefully
More informationSECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
More informationPrefabricated building PVC vertical sliding window
Prefabricated building PVC vertical sliding window SLOVENSKO ITALIA ESPAÑA ITALIA The company, we have the pleasure to introduce in this brochure, is an important and dynamic industrial company located
More informationSEM Model 23/5 GREEN VALUE KIT Medium / Heavy Duty Disintegrator & Briquettor System
SEM Model 23/5 GREEN VALUE KIT Medium / Heavy Duty Disintegrator & Briquettor System SEM GREEN VALUE KIT bundles your disintegration needs with our ECO-Friendly briquetting system, making the most GREEN
More informationVA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation
More informationWhat makes DECRA Roofing Systems unique?
Commercial Roofing As the pioneer of stone coated steel technology, Roofing Systems have been proven around the world since 1957. Marketed and installed in over 120 countries, there are over 1 million
More informationThink Of Us First! When It s Time to Distribute Your Plans
Think Of Us First! When It s Time to Distribute Your Plans CONSTRUCTION NOTEBOOK WILL LIST YOUR PLANS AND SPECS FREE CALL TODAY FOR DETAILS 702-876-8660 Why use Experience We have over 60 years of experience
More informationSAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010
Best Barns USA Assembly Book Revised November 29, 2010 SAMPLE INSTRUCTIONS the Denver 12'x 12' or 12'x16' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775
More informationFire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.
Fire & Soundproofing Insulation Roxul SAFE N SOUND Fire and Soundproofing Insulation for Interior Partition Walls and Floors. Roxul SAFE N SOUND Sound control and fire safety from one batt Insulation.
More informations ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In
Family GUIDE FOR RESIDENTIAL applications Foamular Where quality and performance make a home The OWENS CORNING FOAMULAR XPS INSULATION FAMILY ALBUM is a critical feature of any home impacting overall comfort
More informationIf you are a web registered user of ArlingontPermits.com you may also request an inspection at:
TECHNICAL BULLETIN Community Development & Planning, Building Inspections TOPIC: Permits & Inspections for Roofing Replacement Effective November 1, 2011 Revised This Technical Bulletin will provide contractors
More informationHow To Compare Roofing Material
Roofing Material Comparisons Housing Fact Sheets One of the great strengths of our market economy is the number of product choices we are provided with. So when it comes time to replace the roof on your
More informationLIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.
LIFE SAFETY UPDATE FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc. The purpose of this update is as follows: Remind all state
More informationMTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS
Los Angeles, CA Project Manual and Specification DIVISION 1 GENERAL CONDITIONS 01 01 10 STATEMENT OF WORK 01 11 00 SUMMARY OF THE WORK 01 14 05 METRO (OWNER) - DIRECTED STOPPAGES 01 20 00 PRICE AND PAYMENT
More informationATLANTA MODEL SPECIFICATIONS
ATLANTA MODEL 50 SPECIFICATIONS Dimensions: Roof Dimensions (point to point) 50-0 Column Dimensions (out to out of columns) 44-0 Eave Height 8-0 Roof Height @ Peak ±21-8⅞ Hip Roof 6:12 pitch Square Feet
More informationBuilding Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
BUILDING ENVELOPE DESIGN BY ROXUL Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB Exterior
More information07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
More informationDrum Dispensing Stations
Drum Dispensing Stations O Safely Dispense from 55 Gallon Drums over a Spill Compliant Sump. 1-2-and 4 drum models available Drums are securely held on racks by galvanized positioners Sump and frame constructed
More information