STI Gasketed Sewer Fittings SDR 35 Injection Molded in Sizes 4 12 Fabricated in Sizes 15 36
|
|
- Sophia Simon
- 7 years ago
- Views:
Transcription
1 STI Gasketed Sewer Fittings SDR 35 Injection Molded in Sizes 4 12 Fabricated in Sizes G STI fittings feature a one-piece integral bell and an extended prealignment entrance that aids in proper alignment of pipe and fittings. In addition to scientifically formulated resins, square pipe stops resist pipe push-through while extra heavy support is provided under the pipe stop at branch intersections for added strength. Where available, reducing branches on injection molded 8, 10, and 12 tees, wyes, and tee-wyes shall be minimum DR18 wall thickness in the reducing branch body and reducing branch hub area below the gasket race. Applications STI Gasketed Sewer fittings are intended for non-pressure drainage of sewage and surface water. Certification STI Gasketed Sewer fittings are third party tested and listed by NSF, UPC and CSA to meet specifications defined in ASTM D 3034, ASTM F 1336 and CSA B182.2, where applicable. Product Spotlights Controlled Settlement Joint The controlled settlement joint (CSJ) inhibits penetration of the riser through the lateral connection and into the waterway. The new double gasketed CSJ is a slip joint that permits a maximum of 5-1/2 of axial movement of the riser with forces exceeding 500 lb/feet. Riser movement typically occurs from settlement forces or concentrated loads resulting from elevation changes in service connections. The controlled settlement joint in conjunction with proper backfill techniques, offers a solution that inhibits damage such as splitting, cracking, or spearing. As a result, this minimizes costly excavation and replacement of damaged system components. Plastic Trends Controlled Settlement Joint has certification listing through CSA. It is available in diameters of 4, 5, or 6 and in SDR 26, SDR 28, or SDR 35. Refer to page G8 for pricing and available configurations. Vertical Riser Adapter (G984, G986, G988) This simple solution in conjunction with the unique integral flange, Short Specs STI Gasketed Sewer Fittings SDR 35 (4-12 ) 4 through 12 injection molded gasketed SDR 35 sewer fittings shall be manufactured in accordance with ASTM D 3034, ASTM F1336, and CSA B They shall be injection molded from virgin PVC compound having a cell classification of or in accordance with, and certified by the National Sanitation Foundation (NSF), to meet ASTM D Gaskets shall be manufactured in accordance with ASTM F 477 or ASTM F 913. Gaskets shall be firmly seated in fitting in order to ensure proper installation and to prevent dislocation or misalignment during system assembly. Gasket joints must comply with ASTM D 3212 Internal Pressure Test (exfiltration) and Vacuum Test (infiltration) at 5 degrees of gasket joint deflection and top load deflection. Where available, reducing branches on injection molded 8, 10, and 12 tees, wyes, and tee-wyes shall be minimum DR18 wall thickness in the reducing branch body and reducing branch hub area below the gasket race. Gasketed SDR 35 sewer fittings shall be certified by the National Sanitation Foundation (NSF) and, in applicable configurations, by the International Association Of Plumbing And Municipal Officials (IAPMO) to meet ASTM D 3034, and by the Canadian Standards Association (CSA) to meet CSA B ATTENTION: Plastic Trends fittings are not to be used with compressed air or gases. Plastic Trends does not recommend that piping systems that include its products be tested with compressed air or gases. inhibits system failure due to pipe spearing beyond the pipe stop. Refer to page G10 for pricing and available configurations. Third y Tested Sam Roberts & Associates, Inc. South Texas North Texas 3300 Capitol 1220 Round Table Dr. Houston, Texas Dallas, Texas Fax: Fax:
2 *Denotes Molded Fitting Items in Bold feature Heavy Duty Branches (SDR18) Third party tested and listed by CSA, NSF and UPC Denotes Assembled *Denotes from Molded Molded Components Fitting Items in Bold feature Heavy Duty Specifications: Branches (SDR18) ASTM D3034, Third F1336, party CSA tested B182.2 and listed by CSA, NSF and UPC Denotes Assembled from Molded Components Additional Sizes Available Upon Request Page G1 Additional Sizes Available Upon Request Non-Stock items are non-cancelable, non-returnable Page G2 Stan Roberts & Associates, Inc Houston Dallas Straight Tee GxGxG 45 Degree Wye GxGxG *4 x 4 G *4 x 4 G *6 x 4 G *6 x 4 G *6 x 6 G *6 x 6 G *8 x 4 G *8 x 4 G *8 x 6 G *8 x 6 G *8 x 8 G *8 x 8 G *10 x 4 G *10 x 4 G *10 x 6 G *10 x 6 G *10 x 8 G *10 x 8 G *10 x 10 G *10 x 10 G *12 x 4 G *12 x 4 G *12 x 6 G *12 x 6 G *12 x 8 G *12 x 8 G *12 x 10 G *12 x 10 G *12 x 12 G *12 x 12 G x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 12 L x 12 L , x 15 L , x 15 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , x 27 L , x 27 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , x 27 L , x 27 L , x 30 L , x 30 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , x 27 L , x 27 L , x 30 L , x 30 L , x 36 L , x 36 L ,850.64
3 Straight Tee SxGxG Gasketed Sewer Fittings SDR35 45 Degree Wye SxGxG *4 x 4 G *4 x 4 G *6 x 4 G *6 x 4 G *6 x 6 G *6 x 6 G *8 x 4 G *8 x 4 G *8 x 6 G *8 x 6 G *8 x 8 G *8 x 8 G x 4 G x 4 L x 6 G x 6 L x 8 G x 8 L x 10 G x 10 L x 4 G x 4 L x 6 G x 6 L x 8 G x 8 L x 10 G x 10 L x 12 G x 12 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , x 27 L , x 27 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , x 27 L , x 27 L , x 30 L , x 30 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , x 27 L , x 27 L , x 30 L , x 30 L , x 36 L , x 36 L , G *Denotes Molded Fitting Items in Bold feature Heavy Duty Branches (SDR18) Third party tested and listed by CSA, NSF and UPC *Denotes Denotes Molded Assembled Fitting from Molded Items Components in Bold feature Heavy Duty Branches (SDR18) Denotes Additional Assembled Sizes Available from Upon Molded Request Components Specifications: Third party tested ASTM D3034, and listed F1336, by CSA, NSF B182.2 and UPC Non-Stock Additional items Sizes are non-cancelable, Available Upon non-returnable Request Page G2 Page G3
4 *Denotes Molded Fitting Items in Bold feature Heavy Duty Branches (SDR18) Third party tested and listed by CSA, NSF and UPC Denotes Assembled *Denotes from Molded Molded Components Fitting Items in Bold feature Heavy Duty Specifications: Branches (SDR18) ASTM D3034, Third F1336, party CSA tested B182.2 and listed by CSA, NSF and UPC Denotes Assembled from Molded Components Additional Sizes Available Upon Request Page G3 Additional Sizes Available Upon Request Non-Stock items are non-cancelable, non-returnable Page G4 Stan Roberts & Associates, Inc Houston Dallas Straight Tee with DWV Branch GxGxDWV G 45 Degree Wye with DWV Branch GxGxDWV G *8 x 4 H *8 x 4 H *8 x 6 H *8 x 6 H x 4 G x 4 L x 6 G x 6 L x 4 G x 4 L x 6 G x 6 L x 4 L x 4 L x 6 L x 6 L x 4 L , x 4 L , x 6 L , x 6 L , x 4 L , x 4 L , x 6 L , x 6 L , x 4 L , x 4 L , x 6 L , x 6 L , x 4 L , x 4 L , x 6 L , x 6 L , For fabricated Tees use L Prefix For fabricated Wyes use L Prefix Straight Tee with DWV Branch GxGxDWV H 45 Degree Wye with DWV Branch GxGxDWV H *8 x 4 G *8 x 4 G *8 x 6 H *8 x 6 H x 4 G x 4 L x 6 G x 6 L x 4 G x 4 L x 6 G x 6 L x 4 L x 4 L x 6 L x 6 L x 4 L , x 4 L , x 6 L , x 6 L , x 4 L , x 4 L , x 6 L , x 6 L , x 4 L , x 4 L , x 6 L , x 6 L , x 4 L , x 4 L , x 6 L , x 6 L , For fabricated Tees use L Prefix For fabricated Wyes use L Prefix Combo Wye & 1/8 Bend GxGxG (2 Piece) Double 45 Degree Wye GxGxGxG 4 x 4 G x 4 L x 4 G *6 x 4 G x 6 G *6 x 6 G x 4 G x 4 L x 6 G x 6 L x 8 G x 8 L x 4 G x 4 L x 6 G x 6 L x 8 G x 8 L x 10 G x 10 L x 4 G x 4 L x 6 G x 6 L x 8 G x 8 L x 10 G x 10 L , x 12 G , x 12 L , x 4 L x 4 L x 6 L x 6 L , x 8 L x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L ,273.03
5 Sanitary Tee (T-Y) GxGxG Gasketed Sewer Fittings SDR35 G Sanitary Tee (T-Y) with DWV Branch GxGxDWV G *4 x 4 G x 4 H *6 x 4 G x 6 H *6 x 6 G x 4 L *8 x 4 G x 6 L *8 x 6 G x 4 L *8 x 8 G x 6 L x 4 L x 4 L x 6 L x 6 L , x 8 L x 4 L , x 10 L x 6 L , x 4 L x 4 L , x 6 L x 6 L , x 8 L x 4 L , x 10 L x 6 L , x 12 L , x 4 L , x 4 L x 6 L , x 6 L x 8 L x 4 L , Sanitary Tee (T-Y) with DWV Branch GxGxDWV H 18 x 6 L , *8 x 4 H x 8 L , *8 x 6 H x 4 L , x 4 L x 6 L , x 6 L x 8 L , x 4 L x 4 L , x 6 L x 6 L , x 4 L x 8 L , x 6 L x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 4 L , x 4 L , x 6 L , x 6 L , x 4 L , x 8 L , x 6 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L Sanitary Tee (T-Y) SxGxG Tee Cross GxGxGxG *4 x 4 G x 4 L *6 x 4 G x 4 L *6 x 6 G x 6 L *8 x 4 G x 4 L *8 x 6 G x 6 L *8 x 8 G x 8 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L , x 10 L x 12 L , x 12 L , x 4 L x 4 L x 6 L x 6 L , x 8 L x 8 L , x 4 L , x 10 L , x 6 L , x 12 L , x 8 L , x 15 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 4 L , x 10 L , x 6 L , x 12 L , x 8 L , x 15 L , x 4 L , x 18 L , x 6 L , x 4 L , x 8 L , x 6 L , x 8 L , Way Cleanout GxGxG 24 x 4 L , *4 x 4 G x 6 L , *6 x 6 G x 8 L , x 4 L , x 6 L , x 8 L , *Denotes Molded Fitting Items in Bold feature Heavy Duty Branches (SDR18) Third party tested and listed by CSA, NSF and UPC Denotes Assembled from Molded Components Specifications: ASTM D3034, F1336, CSA B182.2 Additional Sizes Available Upon Request Non-Stock items are non-cancelable, non-returnable *Denotes Molded Fitting Items in Bold feature Heavy Duty Branches (SDR18) Denotes Assembled from Molded Components Third party tested and listed by CSA, NSF and UPC Additional Sizes Available Upon Request Page G4 Page G5
6 Item Stan Roberts & Associates, Inc Houston Dallas Size in Item Size in 1/4 Bend (90) GxG 1/4 Bend (90) SxG *4 G *4 G *6 G *6 G *8 G *8 G *10 G *10 G *12 G *12 G /4 Bend (90) GxG Long Sweep 1/4 Bend (90) SxG Long Sweep *4 G *4 G *6 G *6 G *8 G *8 G G G G G L , L , L , L , L , L , L , L , L , L , L , L , L , L , Deep Socket 1/4 Bend (90) GxG (2 Piece Assembly) Deep Socket 1/4 Bend (90) SxG (2 Piece Assembly) 4 H H H H H H /8 Bend (45) GxG 1/8 Bend (45) SxG *4 G *4 G *6 G *6 G *8 G *8 G *10 G *10 G *12 G *12 G L L L , L , L , L , L , L , L , L , L , L , L , L , Deep Socket 1/8 Bend (45) GxG Deep Socket 1/8 Bend (45) SxG 4 H H *6 H *6 H H H /8 Bend (45) GxG (Extra Long Sweep Radius) 1/8 Bend (45) SxG (Extra Long Sweep Radius) 4 L L L L L L L , L , L , L , L , L , /12 Bend (30) GxG 1/12 Bend (30) SxG 4 L L L L L L L L L L L L L , L , L , L , L , L , L , L , L , L , L , L , *Denotes Molded Fitting Third party tested and listed by CSA, NSF and UPC Denotes Assembled *Denotes from Molded Molded Components Fitting Items in Bold feature Heavy Duty Specifications: Branches (SDR18) ASTM D3034, Third F1336, party CSA tested B182.2 and listed by CSA, NSF and UPC Page G5 Additional Sizes Available Denotes Upon Assembled Request from Molded Components Non-Stock items are non-cancelable, Additional non-returnable Sizes Available Upon Request Page G6
7 Item Size in Gasketed Sewer Fittings SDR35 Item Size in 1/16 Bend (22.5) GxG 1/16 Bend (22.5) SxG *4 G *4 G *6 G *6 G *8 G *8 G *10 G *10 G *12 G *12 G L L L , L , L , L , L , L , L , L , L , L , L , L , Deep Socket 1/16 Bend (22.5) GxG Deep Socket 1/16 Bend (22.5) SxG G 4 H H *6 H *6 H H H /16 Bend (22.5) GxG (Extra Long Sweep Radius) 1/16 Bend (22.5) SxG (Extra Long Sweep Radius) 4 L L14904S L L14906S L L14908S L , L14910S 1-1, L , L14912S 1-2, L , L14915S 1-2, /32 Bend (11.25) GxG 1/32 Bend (11.25) SxG 4 L L L L L L L L L L L L L , L , L , L , L , L , L , L , L , L , L , L , Cap (G) Spigot Plug(S) *4 G *4 G *6 G *6 G *8 G *8 G *10 G *10 G *12 G *12 G L L L L L , L L , L , L , L , L , L , L , L , Stop Coupling GxG Repair Coupling GxG *4 G *4 G *6 G *6 G *8 G *8 G *10 G *10 G *12 G *12 G L L L L L , L , L , L , L , L , L , L , L , L , *Denotes Molded Fitting Third party tested and listed by CSA, NSF and UPC *Denotes Denotes Molded Assembled Fitting from Molded Items Components in Bold feature Heavy Duty Branches (SDR18) Specifications: Third party tested ASTM D3034, and listed F1336, by CSA, NSF B182.2 and UPC Denotes Additional Assembled Sizes Available from Upon Molded Request Components Non-Stock Additional items Sizes are Available non-cancelable, Upon non-returnable Request Page G6 Page G7
8 Stan Roberts & Associates, Inc Houston Dallas Concentric Increaser Coupling GxG Concentric Increaser Bushing SxG *6 x 4 G *6 x 4 G *8 x 4 G *8 x 4 G *8 x 6 G *8 x 6 G *10 x 4 G *10 x 4 G *10 x 6 G *10 x 6 G *10 x 8 G *10 x 8 G *12 x 4 G *12 x 4 G *12 x 6 G *12 x 6 G *12 x 8 G *12 x 8 G *12 x 10 G *12 x 10 G x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 12 L x 12 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 12 L x 12 L x 15 L x 15 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 12 L , x 12 L x 15 L , x 15 L x 18 L , x 18 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , x 27 L , x 27 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , x 27 L , x 27 L , x 30 L , x 30 L , Controlled Settlement Joint GxG Controlled Settlement Joint SxG 4 x 4 H x 4 H x 6 H x 6 H x 8 H x 8 H *Denotes Molded Fitting Third party tested and listed by CSA, NSF and UPC *Denotes Molded Fitting Items in Bold feature Heavy Duty Branches (SDR18) Third party tested and listed by CSA, NSF and UPC Denotes Assembled from Molded Components Specifications: ASTM D3034, F1336, CSA B182.2 Denotes Assembled from Molded Components Additional Sizes Available Upon Request Page G7 Additional Sizes Available Upon Request Non-Stock items are non-cancelable, non-returnable Page G8
9 Eccentric Increaser Coupling GxG Gasketed Sewer Fittings SDR35 Eccentric Increaser Bushing SxG *6 x 4 G *6 x 4 G x 4 L *8 x 4 G *8 x 6 G *8 x 6 G x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 12 L x 12 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 12 L x 12 L x 15 L x 15 L x 4 L , x 4 L x 6 L , x 6 L x 8 L , x 8 L x 10 L , x 10 L x 12 L , x 12 L x 15 L , x 15 L x 18 L , x 18 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 4 L , x 4 L , x 6 L , x 6 L , x 8 L , x 8 L , x 10 L , x 10 L , x 12 L , x 12 L , x 15 L , x 15 L , x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , Gasketed C900 Adapter Coupling GxG Gasket SDR26 Sewer Hub x Gasket C900 Hub Manhole Adapter without Pipe Stop SxG Sand Finish 4 x 4 H x 4 L x 6 H x 6 L x 8 H x 8 L x 10 H x 10 L x 12 H x 12 L x 15 H , x 15 L x 18 H , x 18 L x 21 H , x 21 L x 24 H , x 24 L , x 27 L , x 30 L , x 36 L , Gasketed C900 Adapter Bushing SxG Chamfer SDR26 Sewer Spigot x Gasket C900 Hub Gasketed C900 Adapter Bushing SxG C900 DR25 Spigot x Gasket SDR26 Sewer Hub 4 x 4 H x 4 H x 6 H x 6 H x 8 H x 8 H x 10 H x 10 H x 12 H x 12 H x 15 H , x 15 H , x 18 H , x 18 H , x 21 H , x 21 H , x 24 H , x 24 H , G *Denotes Molded Fitting Third party tested and listed by CSA, NSF and UPC *Denotes Denotes Molded Assembled Fitting from Molded Items Components in Bold feature Heavy Duty Branches (SDR18) Specifications: Third party tested ASTM D3034, and listed F1336, by CSA, NSF B182.2 and UPC Denotes Additional Assembled Sizes Available from Upon Molded Request Components Non-Stock Additional items Sizes are non-cancelable, Available Upon non-returnable Request Page G8 Page G9
10 Stan Roberts & Associates, Inc Houston Dallas Gasketed Sewer Adapter HxG Solvent Sewer Hub x Gasket Sewer Hub Gasketed Sewer Adapter SxG Solvent Sewer Spigot x Gasket Sewer Hub *4 x 4 G *4 x 4 G *6 x 4 G *6 x 6 G *6 x 6 G *8 x 8 G *8 x 8 G x 10 L x 12 L x 15 L x 18 L x 21 L x 24 L , x 27 L , Gasketed DWV Adapter Coupling GxDWV G Gasket Sewer Hub x Gasket DWV Hub Gasketed DWV Adapter Bushing SxDWV G Chamfer Sewer Spigot x Gasket DWV Hub *4 x 4 H *4 x 4 H *6 x 4 H *6 x 4 H *6 x 6 H *6 x 6 H x 8 H x 8 H x 10 H x 10 H x 12 H x 12 H Solvent Sewer to DWV Adapter Coupling HxDWV G Solvent Sewer Hub x Gasket DWV Hub Solvent Weld Sewer Adapter SxH Chamfer Sewer Spigot x Solvent Sewer Hub *4 x 4 H *4 x 4 G *6 x 4 H x 6 G *6 x 6 H x 8 G x 8 H x 10 H x 12 H Solvent DWV Adapter Bushing SxDWV H Chamfer Sewer Spigot x Solvent DWV Hub DWV Adapter Sleeve DWV SxSewer G DWV Spigot x Gasket Sewer Hub *4 x 4 G *4 x 4 G *6 x 4 G *6 x 6 G *6 x 6 G x 8 L *8 x 8 G x 10 L x 10 L x 12 L x 12 L Temporary Plug Polyethylene (S) Vertical Riser Adapter SxS *4 G *4 x 4 G *6 G *6 x 6 G *8 G *8 x 8 G In-Line Backwater Valve GxG IntelliCap with 3M Marker Terminal Backwater Valve (G) 4 L L L L L , L L , L L , L IntelliDisc with 3M Marker *4 P1614-SN *4 P1624-SN *6 P1616-SN *6 P1626-SN Stainless Steel Clamp (QuickLock) Locator for 3M Marker 6 P P POR 8 P Skirt Gasket for Saddle Tee Skirt Gasket for Saddle Wye 4 Inlet G Inlet G Inlet G Inlet G *Denotes Molded Fitting Third party tested and listed by CSA, NSF and UPC *Denotes Molded Fitting Items in Bold feature Heavy Duty Branches (SDR18) Third party tested and listed by CSA, NSF and UPC Denotes Assembled from Molded Components Specifications: ASTM D3034, F1336, CSA B182.2 Denotes Assembled from Molded Components Additional Sizes Available Upon Request Page G9 Additional Sizes Available Upon Request Non-Stock items are non-cancelable, non-returnable Page G10
11 Saddle Tee with Stainless Steel Clamps Short Gasket Skirt x Gasket Inlet Gasketed Sewer Fittings SDR35 Saddle Wye with Stainless Steel Clamps Short Gasket Skirt x Gasket Inlet *6 x 4 G *6 x 4 G *8 x 4 G *8 x 4 G *8 x 6 G *8 x 6 G *10 x 4 G *10 x 4 G *10 x 6 G *10 x 6 G *12 x 4 G *12 x 4 G *12 x 6 G *12 x 6 G *15 x 4 G *15 x 4 G *15 x 6 G *15 x 6 G *18 x 4 G *18 x 4 G *18 x 6 G *18 x 6 G Saddle Tee with Stainless Steel Clamps Extended Solvent Skirt x Gasket Inlet Saddle Wye with Stainless Steel Clamps Extended Solvent Skirt x Gasket Inlet 6 x 4 L x 4 L x 4 L x 4 L x 6 L x 6 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 12 L x 12 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 12 L x 12 L x 15 L x 15 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 12 L x 12 L x 15 L x 15 L x 18 L x 18 L x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 12 L x 12 L x 15 L x 15 L x 18 L x 18 L , x 21 L , x 21 L , x 4 L x 4 L x 6 L x 6 L x 8 L x 8 L x 10 L x 10 L x 12 L x 12 L x 15 L x 15 L x 18 L , x 18 L , x 21 L , x 21 L , x 24 L , x 24 L , x 4 L x 4 L x 6 L x 6 L Skirt Gasket included with 4 and 6 inlets Skirt Gasket included with 4 and 6 inlets Reducing Tee and Reducing T-Y Vertical Riser Kits Reducing 45 Degree Wye Vertical Riser Kit Reducing Tee Kits Reducing 45 Degree Wye Kits 8 x 4 HDB x 4 HDB x 6 HDB x 6 HDB Reducing T-Y Kits 8 x 4 HDB x 6 HDB G Complete job-site ready Vertical Riser Kits include every fitting needed from sewer main to lateral connection, all conveniently packaged and ready for installation. Complete job-site ready Vertical Riser Kits include every fitting needed from sewer main to lateral connection, all conveniently packaged and ready for installation. *Denotes Molded Fitting Items in Bold feature Heavy Duty Branches (SDR18) Third party tested and listed by CSA, NSF and UPC *Denotes Denotes Molded Assembled Fitting from Molded Items Components in Bold feature Heavy Duty Branches (SDR18) Denotes Additional Assembled Sizes Available from Upon Molded Request Components Specifications: Third party tested ASTM D3034, and listed F1336, by CSA, NSF B182.2 and UPC Non-Stock Additional items Sizes are non-cancelable, Available Upon non-returnable Request Page G10 Page G11
12 Stan Roberts & Associates, Inc Houston Dallas Page G12 *Denotes Molded Fitting Items in Bold feature Heavy Duty Branches (SDR18) Denotes Assembled from Molded Components Third party tested and listed by CSA, NSF and UPC Additional Sizes Available Upon Request
LS 2540 SEWER LATERALS AND INSPECTION TEES
LS 2540 SEWER LATERALS AND INSPECTION TEES A. Summary B. Submittals C. Site Information D. Sewer Pipe and Fittings E. Lateral Locations F. Lateral Installation G. Inspection Tee Installation H. Removal
More informationSECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent
More informationSECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
More informationSECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.
SECTION LS 2530 SANITARY SEWERS PART 1 GENERAL 1.1 SUBMITTALS A. General: Submit the following in accordance with The General Conditions. 1. Product data for drainage piping specialties. 2. Shop drawings
More informationSUBMITTAL 10 FEET. Cast Iron Soil Pipe Products Hubless Pipe & Fittings HUBLESS PIPE 10 FEET*
QUALITY SYSTEM SUBMITTAL Hubless Pipe & Fittings R E G I S T R AT I O N Manufacturer s T J B 10 FEET HUBLESS PIPE 10 FEET* NOM. SIZE B INSIDE DIAMETER J OUTSIDE DIAMETER 1 1/2 1.50 1.90 0.16 0.13 28.4
More informationMANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE
SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE PVC materials used in Schedule 40 and Schedule 80 pipe manufactured by Texas United Pipe, Inc., comply with the ASTM Standard D-1784 and are a Type I Grade
More informationSECTION 6 SANITARY SEWER MAIN 6.01 SCOPE
6.01 SCOPE The work covered by this section of the specifications consists of the furnishing of all plant, labor, materials, equipment and supervision and performing all operations involved in the construction
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS
San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS 854.1 DESCRIPTION: This item shall govern sanitary sewer laterals installed in accordance with these
More information08003-1 WATER SERVICE 2
08003_Mar08_2011.pdf Page 1 of 7 INDEX Page 08003-1 WATER SERVICE 2 1.1 Pipe 2 1.1.1 Copper 2 1.1.2 Polyethylene 2 1.2 Valves and Fittings 2 1.2.1 Main Stops 3 1.2.2 Curb Stops 3 1.2.3 Curb Box 3 1.2.4
More informationDIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant
More informationSUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.
SUBDRAINS AND FOOTING DRAIN COLLECTORS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subdrains B. Subdrain Cleanouts and Outlets C. Footing Drain Collectors D. Storm Sewer Service and Connections 1.02 DESCRIPTION
More informationTown House 11265 Center Highway North Huntingdon, PA 15642
APPENDIX C SPECIFICATIONS FOR THE CONSTRUCTION OF BUILDING LATERAL SANITARY SEWERS DECEMBER 2004, INCLUDING AMENDMENTS ADOPTED ON FEBRUARY 6, 2008 AND APRIL 2, 2008; EFFECTIVE ON MAY 1, 2008 Town House
More informationConduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
More informationSECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
More information32-02.05 Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.
SECTION 32: SANITARY SEWER INSTALLATION 32-01 SCOPE. The Work shall consist of furnishing and installing sewer mains, manholes, laterals, cleanout fittings and appurtenances; and testing, flushing and
More informationEXHIBIT "A. Technical Specifications for Water and Sewer Service Lines
EXHIBIT "A Technical Specifications for Water and Sewer Service Lines Water and Sewer Line Bedding and Backfill: Drawings show cross-section of trench, pipe laid on top of 6" min. bedding material, bedding
More informationTABLE OF CONTENTS SECTION 500 SANITARY SEWER AND FORCE MAIN
TABLE OF CONTENTS SECTION 500 SANITARY SEWER AND FORCE MAIN Starts on Page 500 GENERAL... 2 501 MATERIALS... 2 502 CONSTRUCTION PROCEDURES... 7 503 ABANDONMENT OF EXISTING SANITARY SEWER FACILITIES...
More informationDIVISION 4300 STORM DRAINAGE
DIVISION 4300 STORM DRAINAGE SECTION 4305 STORM SEWER PART 1 - GENERAL 1.01 SCOPE This section covers the construction of storm sewers for the collection and transport of stormwater runoff. 1.02 REFERENCES
More informationBeacon Hill Sewer District Standard Specifications
Beacon Hill Sewer District Standard Specifications Residential Gravity Side Sewer Including Design Criteria and Standard Construction Drawings Residential Gravity Side Sewer Design Criteria 1. Provisions
More informationSECTION 221413 FACILITY STORM DRAINAGE PIPING
SECTION 221413 FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationNative InDesign 2890 SaniTite Brochure 1/8" 100 300 CMYK April 17, 07
Sanitary Sewer Pipe Tough pipe for a tough environment SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling, toughness
More informationSpecification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe
Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe 1. GENERAL The following supplemental sewer main specifications are intended to address the installation of high-density polyethylene
More informationThe Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe
The Most Advanced Name in Drainage Systems Sanitary Sewer Pipe SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling,
More informationABS DWV FITTINGS ABS-0215 FEBRUARY 2015 SUPERCEDES ABS-1214 ASTM D2661
ABS DWV FITTINGS ABS-0215 FEBRUARY 2015 SUPERCEDES ABS-1214 ASTM D2661 COUPLING 1 1/4" 601112 125 9,000 2.60 1 1/2" 601120 125 9,000 1.74 2" 601138 100 4,800 2.34 3" 601146 45 1,440 6.57 4" 601153 25 800
More informationThe Manitoba Water Services Board SECTION 027030 Standard Construction Specifications September 2013 Page 1 of 21
September 2013 Page 1 of 21 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of sewers including: the supply and installation of pipe, saddles, tees,
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS
ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by
More informationINDEX. Sec. No. Items Page Nos.
INDEX Sec. No. Items Page Nos. 1. Types of Pipe............... MSSP- 2 2. Concrete Pipe............... MSSP- 2 thru MSSP-3 3. ABS and PVC Truss Pipe............... MSSP- 3 4. ABS and PVC Solid Wall Pipe...............
More informationSewage Compliance Form Instructions
CITY OF JOHNSTOWN DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT 401 MAIN STREET ROOM 200 JOHNSTOWN, PA 15901 814-533-2017 FAX 814-539-5816 RENEE K. DALY DIRECTOR Sewage Compliance Form Instructions 1)
More informationSANITARY SEWER SPECIFICATIONS
SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,
More informationSECTION 02401 - SANITARY SEWER PIPE
PART 1 - GENERAL 1.1 DESCRIPTION A. The WORK under this Section includes providing all labor, materials, tools and equipment necessary for furnishing and installing sanitary sewer pipe, in accordance with
More informationSERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS
1001 SOUTH LEECHBURG HILL LEECHBURG, PA 15656 Phone: 724-845-9355 Fax: 724-845-1186 SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS 1. General
More informationSECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES
SECTION 33 05 16.13 PRECAST CONCRETE PART 1 - GENERAL 1.01 SECTION INCLUDES A. This item shall consist of the construction of both sanitary and storm sewer precast concrete manholes in accordance with
More informationGAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES
GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today
More informationBethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL
155 E. Front Street (rear) Lititz, PA 17543 Phone (717) 625-1930 Fax (717) 625-1931 Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL CONSTRUCTION SPECIFICATIONS AND DETAILS
More informationStandard Specifications For Private Sewer Laterals
BUILDING SERVICES DEPARTMENT 250 Frank H. Ogawa Plaza, 2nd Floor, Oakland, CA 94612 Inspection Services: 510.238.3443 FAX: 510.238.2263 Standard Specifications For Private Sewer Laterals APPROVED MATERIALS
More informationSTANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY
STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY Approved and adopted as Official Document Number 800576 this 10th day of December, 1980 Donald R. Boyd, P.E., Director Water
More informationENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology
ENGINEERED SOLUTIONS A2 Liner Pipe for Trenchless Technology A2 Liner Pipe Restores Deteriorated Sewers Cost-Effective Rehabilitation The increasing rate of sanitary and storm sewer deterioration requires
More informationSECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)
CHAPTER 9 SEWER / STORM DRAIN / IRRIGATION LINES SECTION 9.01 GENERAL This section covers the requirements for piping materials and installation of Lehi City sewer, storm drainage and irrigation collection
More informationSECTION 3 SANITARY SEWER DESIGN
SECTION 3 SANITARY SEWER DESIGN 3.1 GENERAL DESIGN CRITERIA 3.1.1 Requirement for Sanitary Sewer 3.1.2 Design Approval 3.1.3 IEPA Permit Required 3.1.4 Differentiation Between Public and Private Sanitary
More informationSANITARY SEWER SERVICE LEADS OR RECONNECTIONS CITY OF PEARLAND. Section 02531 1.0 G E N E R A L 1.01 SECTION INCLUDES
ITY OF PRLN SNITRY SWR SRVI LS OR RONNTIONS Section 02531 SNITRY SWR SRVI LS OR RONNTIONS 1.0 G N R L 1.01 STION INLUS Installation of service stubs on new sanitary sewers serving areas where sanitary
More informationFabricated Drainage Products
Fabricated Drainage Products Complete Drainage System Inline Drains are used At the beginning of a drain line Add a new water inlet to an existing drain line using a riser pipe and tee HARCO Surface Drainage
More informationA. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.
PART 1 GENERAL 1.1 SCOPE A. This item shall include the work necessary for the installation of storm sewer line construction. B. Reference Section 3800 Trenching and Backfill and the General Conditions,
More information倀 䰀 唀 䴀 䈀 䤀 一 䜀 刀 䄀 䤀 一 圀 䄀 吀 䔀 刀 匀 夀 匀 吀 䔀 䴀 匀
倀 䰀 唀 䴀 䈀 䤀 一 䜀 刀 䄀 䤀 一 圀 䄀 吀 䔀 刀 匀 夀 匀 吀 䔀 䴀 匀 眀 眀 眀 最 攀 渀 漀 瘀 愀 瀀 爀 漀 搀 甀 挀 琀 猀 挀 漀 洀 㠀 ⴀ 㔀 ⴀ 㜀 㐀 㠀 㠀 September 2015 R.F. Williams, Michigan Master Plumber, License No. 04287 (left) R.M. Williams, Michigan
More informationPLUMBING ROUGH IN INSPECTION
This Program is made Possible through the Code Officials Education & Training Fund. Revenue for the Fund comes from Assessments on Building Permits. Please turn down cell phones and put pagers on vibrate.
More informationPVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.
CONDENSED CATALOG PVC HPB-0-A Effective 9//97 Revised //99 CLEAR / / / / -/ -/ -/ x/ CLEAR / / / / -/ PVC SDR. PSI (Water @ 7. F.) /.0.9.0.0 PVC SDR -/ -/ -/ 0 0 PVC SCHEDULE 0.0.7.0.00..7.7.00.000.00...
More informationGeneral Guidelines for Repairing Buried PE Potable Water Pressure Pipes
515 General Guidelines for Repairing Buried PE Potable Water Pressure Pipes Introduction Traditional piping systems have gasket-sealed bell and spigot joints every 20 feet, which can be a potential maintenance
More informationCHAPTER 6 - SANITARY SEWER
CHAPTER 6 - SANITARY SEWER 6.1 GENERAL This section covers the requirements for PVC plastic sewer pipe materials and installation in sanitary sewer construction. 6.2 PIPE PVC gravity sewer pipe and fittings
More informationRoyal Seal Gasketed Sewer Pipe
Royal Seal Gasketed Sewer Pipe Royal Seal Gasketed Sewer Pipe Royal Seal gasketed sewer pipe with our specially designed Double Seal Locked-In (DSLI ) gasket is an extremely durable pipe with a leak proof
More informationSection 2100-Trenching and Tunneling
SECTION 5200 - STORM SEWER PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of storm sewer mains and culverts. Topics include permits and fees, trench widths, pipe laying, bedding, initial
More informationModel Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer
Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer The user may choose to adopt part or all of this Model Specification; however, the user should ensure that all parts
More informationA. This Section includes the following for soil, waste, and vent piping inside the building:
June 2014, Draft 01 22 1316 Sanitary and Waste Vent Piping PART 1. GENERAL 1.01 Summary A. This Section includes the following for soil, waste, and vent piping inside the building: 1. Pipe, tube, and fittings.
More informationSECTION 16402 UNDERGROUND ELECTRIC SERVICE
SECTION 16402 UNDERGROUND ELECTRIC SERVICE PART 1 GENERAL 1.1 SUMMARY A. Description of System 1. Furnish all labor, materials, and equipment for below grade work external to buildings as required, and
More informationShower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
More informationLet Us Give Utilities the Respect that they Deserve.
Water & Sewer Utilities Miscellaneous Design and Plan Preparation Guidelines Issued by: Ray Mowla, P.E. Jefferson Parish Department of Engineering, Utilities Section The purpose of issuing these miscellaneous
More informationHose Clamps & Fittings
All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw
More informationSECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION PART 1 GENERAL.01 SECTION INCLUDES Furnishing and installing 4 inch through 16 inch high density
More informationState of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
More information53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:
Division 53: Slip-Lining of Existing Sewer Line 53.01 GENERAL: This section includes all labor, materials, transportation, equipment necessary to rehabilitate by means of Instituform deteriorated sections
More informationCW 2130 - GRAVITY SEWERS TABLE OF CONTENTS
August 2010 CW 2130 - GRAVITY SEWERS TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Construction Specifications... 1 1.4 Referenced Standard Details...
More informationNEW CONNECTION INDUSTRIAL PRODUCTS NC.10V NC.20V NC.30V. NC. SD.10 NC. SD.20 NC. F.Clamp
Repair and Construction. Complete stainless steel pipe repair clamps to repair cracks, fractures, pin holes, torn sockets or welded tees, broken asbest-cement pipe coupling and more. Available for all
More information3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.
The following shall serve as the minimum requirements for contractors performing work in relation to the Authority s potable water and sanitary sewer system(s), appurtenances and service connections. General:
More informationSewer Line Rehabilitation
1.0 GENERAL 1.1 DESCRIPTION: This specification shall cover the rehabilitation of existing sanitary sewers using the GRUNDOCRACK PIPE BURSTING SYSTEM. Pipe bursting is a system by which the pneumatic bursting
More informationSTANDARD SPECIFICATIONS SECTION 02701 INSTALLATION OF GRAVITY SEWER PIPELINES. 1. Trenching, Backfilling and Compacting: 02223
STANDARD SPECIFICATIONS SECTION 02701 INSTALLATION OF GRAVITY SEWER PIPELINES PART 1 - GENERAL A. Description This section describes the installation of gravity sewer pipelines fabricated of vitrified
More informationSECTION 08000 STORM DRAINAGE TABLE OF CONTENTS
SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING
More informationJay R. Smith Mfg. Co.
Jay R. Smith Mfg. Co. Automatic Backwater Valve SMITH CUSTOMER DRIVEN FLOOD-GATE FEATURES Index Page Flood-Gate Features and Applications 2 How Flood-Gate Works 3 Flood-Gate Operation & Approvals 4 Valve
More informationASTM C76, Class III, Wall B, except as modified herein. Clean natural sand, ASTM C33. Artificial or manufactured sand will not be permitted.
SECTION 3000 - SANITARY SEWERS 3001 SCOPE. This section applies to sanitary sewer construction and shall consist of furnishing all labor, materials, and equipment for the complete installation of sewers
More informationSECTION 02700 SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS
SECTION 02700 SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the General and Supplementary Conditions and Division 1 Specification
More informationSection 02702 SEWER PIPE INSTALLATION AND TESTING
PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete
More informationSECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING
SECTION 33 41 13 PUBLIC STORM PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm drainage piping, fittings, and accessories at proposed station areas and locations other than under and immediately adjacent
More informationBUILDING SEWER CONNECTION REQUIREMENTS
BUILDING SEWER CONNECTION REQUIREMENTS ANY PERSON DESIRING TO MAKE A NEW OR REVISED SEWER INSTALLATION MUST FIRST MAKE APPLICATION WITH THE NORTHERN GILA COUNT SANITARY DISTRICT FOR A PERMIT BEFORE STARTING
More informationCHAPTER 11 STORM DRAINAGE
CHAPTER STORM DRAINAGE SECTION PC 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. Storm water discharge shall be
More informationSeptember 2012 Brunswick County Engineering Department Revision 1.0. Technical Specification 020.01 GRAVITY SANITARY SEWER SYSTEM
1.0 General Technical Specification 020.01 GRAVITY SANITARY SEWER SYSTEM a) It is the intent of this specification to ensure that all gravity sewer system infrastructure constructed within the service
More informationVolume III: PVC Solvent. Weld BDS Sewer & Drain Piping Systems. Mechanical Technical Manual Series
Volume III: PVC Solvent TM Weld BDS Sewer & Drain Piping Systems Mechanical Technical Manual Series F I R S T E D I T I O N P V C S O LV E N T W E L D P I P E & F I T T I N G S Sanitar y drain & building
More informationCHAPTER 11 STORM DRAINAGE
CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,
More informationFY08 SEWER POINT REPAIRS BID TABULATION
6-07-831 Page 1 of 12 1 FOR CLEANING AND TELEVISING EXISTING SEWERS, AS SPECIFIED, ANY REQUIRED CLEANING, ANY LOCATION, ANY LENGTH OF SEWER, COMPLETE IN PLACE, FOR VARIOUS PIPE DIAMETERS. A. EXISTING "
More informationNote: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.
CHANNEL DrAiNS Durable Designed for maximum durability and drainage, NDS Channel Drains are a proven alternative to traditional concrete drains. UV inhibitors in the grates, channel and component parts
More informationEngineering Specifications
PUREFLOW PEX PRODUCTS PART 1 GENERAL 1.1 SUMMARY 1.1.1 This specification covers Branch & Main, Parallel Water Distribution Systems (MANABLOC), Cross-linked Polyethylene tubing and fittings using PEX Press
More informationProduct Knowledge Guide. (Updated May 2015) BR-PK 2004-2015 Charlotte Pipe and Foundry Company.
Product Knowledge Guide (Updated May 2015) BR-PK 2004-2015 Charlotte Pipe and Foundry Company. You can t beat the system. Charlotte Pipe s Retail Division Charlotte Pipe and Foundry Company is the largest
More informationSPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown
More informationSECTION 603 SANITARY SEWER FORCE MAINS
SECTION 603 SANITARY SEWER FORCE MAINS 1. GENERAL Pipelines for sanitary sewer force main systems shall conform to the following specifications and shall be installed at the locations indicated on the
More informationWATER & SEWER CORROSIVE RESISTANT PRODUCTS
WATER & SEWER CORROSIVE RESISTANT PRODUCTS The Standard of Excellence in the Industry CASING SPACERS COUPLINGS & FLANGE COUPLING ADAPTERS REPAIR CLAMPS DUCTILE IRON SADDLES STAINLESS STEEL SADDLES TAPPING
More informationSANITARY DRAINAGE CHAPTER 7
CHAPTER 7 SANITARY DRAINAGE SECTION 701 GENERAL 701.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of sanitary drainage systems. 701.2 Sewer required.
More informationSECTION 02732 BUILDING SEWERS. B. Connection of building sanitary drainage system to municipal sewers.
SECTION 02732 BUILDING SEWERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Lateral piping, fittings, and accessories. B. Connection of building sanitary drainage system to municipal sewers. 1.02 REGULATORY
More informationWATER MAIN CONSTRUCTION TECHNIQUES DEPARTMENT OF PUBLIC WORKS WATER & WASTEWATER DIVISION
WATER MAIN CONSTRUCTION TECHNIQUES Overview Water Main - Materials Specifications Installation Future? Water Main Materials Material Types There are various material types used for water mains, these include:
More informationTop 10+ Mistakes of DWV plumbing design
Top 10+ Mistakes of DWV plumbing design Listed below are the some of the most frequently missed items, noticed by our inspectors, at plumbing rough-in when non-plumbers attempt plumbing design. Most of
More informationSECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
More informationARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH 020001 Purpose and Application.
ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH 020001 Purpose and Application. Article II provides rules governing the allowable connection to the City POTW and the construction and inspection of
More informationPVC Gasketed & Solvent Weld Pipe
PVC Gasketed & Solvent Weld About Royal Building Products Royal Building Products has been in business for over 100 years when Royal Abbotsford, Canada facility started producing clay. With shift in demand
More information8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P-24258 B-24258 E-24259 B-24259 B-24266 B-24267
BALL ANGLE METER VALVES - 3/4" & " 8D. B-24258 MUELLER 300 Ball Angle Meter Valve MUELLER 0 Conductive Compression Connection for CTS O.D.* tubing x meter swivel nut** adding -3 suffix to catalog number.
More information2006 Codes. Please verify the following before calling for inspection
INSPECTION CHECKLIST RESIDENTIAL PLUMBING ROUGH IN 2006 Codes This checklist is intended for use to prepare for an inspection. This is only a general list and is not intended to address all possible conditions.
More informationThe work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
Section 33 0200- Page 1 of 4 PART 1 - GENERAL 1.1 DESCRIPTION OF WORK The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
More informationUni-Quick Duct System. Moveable. Uni-Quick. Duct System. DUST COLLECTION and MATERIAL HANDLING APPLICATIONS a McGill AirFlow product
United McGill products Uni-Quick TM An enterprise of United McGill Corporation Family owned and operated since 1951 Moveable Duct System DUST COLLECTION and MATERIAL HANDLING APPLICATIONS a McGill AirFlow
More informationSECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD
SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD 21.01 SCOPE: It is the intent of the Specification to define the approved methods and materials
More informationSANITARY DRAINAGE CHAPTER 7
CHAPTER 7 SANITARY DRAINAGE SECTION 701 GENERAL 701.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of sanitary drainage systems. 701.2 Sewer required.
More informationMS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water
MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org HDPE
More informationSECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
More informationSEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER
Village of Shorewood, Wisconsin SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER Prepared By: Thomas A. Zoulek, P.E., LEED A.P. Vice President Mid City Plumbing & Heating
More informationSchedule 40 & Schedule 80 Rigid PVC Piping Systems Scroll Down for Dimensions, Components, Hangars & Supports, Fabrication Techniques
Schedule 40 & Schedule 80 Rigid PVC Piping Systems Scroll Down for Dimensions, Components, Hangars & Supports, Fabrication Techniques Schedule 40 Rigid PVC Piping Systems SCHEDULE 40 - DIMENSIONS Harvel
More informationFY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation
644-10-569 Page 1 of 9 1 FOR CLEANING AND TELEVISING EXISTING SEWERS, AS SPECIFIED, ANY REQUIRED CLEANING, ANY LOCATION, ANY LENGTH OF SEWER, COMPLETE IN PLACE, FOR VARIOUS PIPE DIAMETERS. A. EXISTING
More informationARTICLE VI (ALTERNATE) STANDARD SPECIFICATIONS. for (PVC) SANITARY SEWER MAIN CONSTRUCTION
ARTICLE VI (ALTERNATE) STANDARD SPECIFICATIONS for (PVC) SANITARY SEWER MAIN CONSTRUCTION VI(A).1 General VI(A).2 Materials and Equipment VI(A).3 Installation of Sanitary Sewer Mains VI(A).4 Laying of
More information