1 E S 85. Industrial Regulator Series / M Quality System QMI is ccredited by: R E I T ISO 9 Registered R E NSI R G I S T R R utch ouncil for ccreditation Measurement Engineers Since 86

2 merican Meter Series and Worker/Monitor Regulators Worker/Monitor sets are commonly used to provide overpressure protection. worker/monitor installation consists of a monitor with an external static connection and a worker with an internal static connection. The regulator selected to be the monitor is set at " to 5" w.c. above the worker. The external static connection is connected at a point free of turbulence and preferably a minimum of five pipe diameters downstream. Improved Features and Series Monitor onversion merican Meter offers four industrial monitor regulators the M, M, 88M and 8M. esign improvements now enable all models to be configured as Monitor Regulators. This change was effective with all and Series Regulators manufactured after January 99. The advantage is that two models of the same regulator need not be stocked. ll models are pre-machined to accept a monitor conversion kit. Refer to IMP 87 for kit numbers and installation instructions. When a regulator with an OPSO is converted to a monitor, a sense line must extend downstream of the worker, as shown in the diagram to the right. ONTROLLING MONITOR /" Typical Upstream Monitor Installation

3 The merican Meter Industrial Regulator Monitor onversion The body and valve head are premachined to allow easy conversion to a monitor model. See page for more information. Rugged onstruction Valve heads are ductile iron which prevents thread damage. vailable as -/" and " screwed, and " flanged connections. NSI, SP and IN connections available. Springs The Series spring ranges from.5" w.c. to 5 outlet pressure. Series spring ranges from / to 5 outlet pressure. See page. Interchangeable Orifice vailable in sizes from /" through -/" for a wide range of flow rates. One orifice is offered for both standard and OPSO models to minimize spare-parts inventory. OPSO Overpressure Shutoff for positive protection of public buildings such as schools, churches, etc. See page 5. Maintenance Three setscrews hold diaphragm case to the valve head, providing the easiest orifice and seat disc inspection in the industry. Pressure Taps The and Regulators have inlet and outlet pressure taps. Relief Vent " vent for Full Relief overpressure protection in three models, such as the 8. Partial Relief has " vent and Series has /". See page 7 for relief performances. urability ast-aluminum top and bottom diaphragm case for long service life. UPSO Snap-acting lever for underpressure shutoff protection when line pressure drops drastically.

4 merican Meter Regulators Other Features 8 Partial Relief Series low-pressure models have a maximum inlet pressure of 5 and offer outlet pressures ranging from.5" w.c. to 5. Series high pressure models allow a maximum inlet pressure of 5 and outlet pressures ranging from.5 to 5. The Series can be ordered as Full Relief, Partial Relief or No Relief Regulator as shown in the table. Series Regulators are non-relieving. oth models are available with Overpressure Shutoff, Underpressure Shutoff and monitor capabilities. Low Pres. Model imensions Numbers escription *E Standard Regulator.75" ".75" 6".5" M Standard Monitor Regulator.75" ".75" 6".5" 8 Partial Internal Relief Regulator.75" ".75" 6".5" 8 Full apacity Internal Relief Regulator.75" ".75" 6".5" 8 Underpressure Shutoff.75" ".75" 6".5" 8 Underpressure Shutoff with Partial Internal Relief.75" ".75" 6".5" 8 Underpressure Shutoff with Full Internal Relief.75" ".75" 6".5" 8 Overpressure Shutoff with Partial Internal Relief.75" " 5.6" 9.87".5" 8 Overpressure Shutoff with Full apacity Internal Relief.75" " 5.6" 9.87".5" 85 Overpressure and Underpressure Shutoff with Partial Internal Relief.75" " 5.6" 9.87".5" 85 Overpressure and Underpressure Shutoff with Full apacity Internal Relief.75" " 5.6" 9.87".5" 88 Overpressure Shutoff.75" " 5.6" 9.87".5" 88M Overpressure Shutoff with Monitor.75" " 5.6" 9.87".5" 89 Overpressure and Underpressure Shutoff.75" " 5.6" 9.87".5" High Pres. Model imensions Numbers escription *E Standard Regulator 8.9" ".75" 6".5" M Standard Monitor Regulator 8.9" ".75" 6".5" Underpressure Shutoff 8.9" ".75" 6".5" 8 Overpressure Shutoff 8.9" " 5.6" 9.87".5" 8M Overpressure Shutoff with Monitor 8.9" " 5.6" 9.87".5" 9 Overpressure and Underpressure Shutoff 8.9" " 5.6" 9.87".5" * " flange valve head is an option; contact Sales Office for information. No Relief Low Pressure E High Pressure E

5 merican Meter UPSO OPSO OUPSO Regulator Safety Features vailable Exclusively From merican Meter On Series and Industrial Regulators Pressure control and automatic shutoff devices for the protection of public buildings, schools, theaters, hospitals, etc. are available in one complete package on several and Series Industrial Regulator models (see page 5). Installing one of these regulators provides automatic protection against possible extreme variations in either inlet or outlet gas pressure. UPSO The UPSO (underpressure shutoff) models provide complete shutoff protection in case of severely interrupted inlet gas pressure. If the inlet or outlet pressure is severely interrupted, causing the regulator to stroke to a full-open position, the shutoff closes, providing complete system safety. The shutoff valve remains closed until manually reset. How The UPSO Operates When gas pressure under the main diaphragm falls below normal, the shutoff device is tripped and the spring, connected with the valve plunger, forces the valve seat against the orifice closing off gas flow. The UPSO must be manually reset to re-establish gas flow. Figure To reset the underpressure shutoff device (Figure ), unscrew the reset plug with a wrench. When it becomes free of the threads, pull it out until it engages the reset mechanism. With the wrench, turn the reset shaft clockwise until the reset mechanism is engaged. Hold firmly in this position until normal pressure is established under the diaphragm and downstream line, and regulator operation is restored. Screw in the reset plug and tighten. Overpressure Shutoff (OPSO) in cocked position Overpressure Shutoff (OPSO) in tripped position OPSO Overpressure shutoff regulator models prevent excessive gas pressure from entering a building causing a hazardous condition. The shutoff device closes if the regulator outlet pressure rises above a maximum set point or set pressure. How The OPSO Operates When line or static pressure increases to the specified overpressure shutoff setting, the pressure on the under side of the shutoff diaphragm over-balances the spring, forcing the diaphragm stem outward, releasing the plunger. This permits the shutoff spring to force the shutoff disc against the orifice, closing off gas flow. The OPSO assembly is part of the regulator but is not connected to the regulator operating mechanism. When selecting a shutoff spring, a minimum differential of " w.c. between normal operating pressures and the shutoff pressure setting should be provided. To reset the overpressure shutoff device, unscrew the seal cap, which opens the regulator orifice, permitting gas flow. Pull out on the seal cap until the overpressure shutoff device latches completely. Tighten the seal cap. o not trip the shutoff valve unless the seal cap is installed. OUPSO Overpressure and underpressure shutoff models combine both safety features for maximum protection. On these models, when the OPSO shuts off, the UPSO automatically trips, providing double assurance of positive gas shutoff. The overpressure shutoff device must be reset first followed by resetting the underpressure shutoff device. 5

6 apacity ata OUTLET PRESSURE INHES W.. OUTLET PRESSURE INHES W " Orifice - Set pressure 7." w.c. at SFH Spring Range 5.5" to 8." 9 5.5,,,, 5, 6, 8, 9,,,,,, RTE OF FLOW - S..F.H. -.6 SP.GR.GS -.7 P.S.I F. " Orifice - Set pressure 7." w.c. at SFH Spring Range 5.5" to 8." 5 6.5,,,, 5, 6, 8, 9,,,,,, RTE OF FLOW - S..F.H. -.6 SP.GR.GS -.7 P.S.I F. merican Meter Model 8 Regulator (-/" and " sizes) Full Relief Valve haracteristics Test performed with orifice valve blocked in wide open position. " screened vent-no vent pipe. Numbers in each circle indicate orifice size. 7" W.. - Set pressure / 7 5 / / " W.. - Set pressure / 5 / / 7 OUTLET PRESSURE (PSIG) 8 6 OUTLET PRESSURE (PSIG) 8 6 / / INLET PRESSURE (PSIG) INLET PRESSURE (PSIG) 9 PSIG - Set pressure / / 5 7 / 5 PSIG - Set pressure / 7 5 / / OUTLET PRESSURE (PSIG) 8 6 / OUTLET PRESSURE (PSIG) INLET PRESSURE (PSIG) INLET PRESSURE (PSIG) 9 6

7 -/" Series apacity ata SFH Gas.6 Specific Gravity 7P7.5" to 6" w.c. Set: 6" w.c. roop: " w.c. Max. ompound: " w.c. 7P9 8.5" to " w.c. Set: " w.c. roop: " w.c. 7P.5" to 8" w.c. Set: roop: 6" w.c. 7P to Set: roop:.6 -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /",,6,, 9 55 /,9,55,,, 6,85,,,,, 75,75,,85,,,5 7,,5,9,7,,7,,75,,6,6,,,,5,9,,,5,,,5,9,,,5,, 5,7 5,,,,,9,, 5 5,7 5,,,,,95,, 7,5 6, 6,,,,,55 7, 6, 6, 5,,,,6 9, 7,9 7,5 6, 5,,85,9 5 9,5 7, 7,5 6, 5,5,85,9 9, 8,7 7, 6,,6, 9, 8,6 7,5 6,,55,,75, 9, 7,7 5,9,85,,7 8,9 8, 5,,,, 9, 7,,,, 9, 7,5,, 9,,5 6, 9,,5 5,85 5, 8, 8, -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /",,,,5 5,, 6, 5, 8, 7,6 9,,9,,55,5 6,6 8, 9,5,,5,, 6, 7, 9,,,,55,6 5, 6,5 7,5,,7,,, 5, 6,5 75,,,,9,,5,,5,85,5 5 5,55,,,,75, 5,7 5, 8, 7, 9,,7,6,, 6, 8, 9,6,5,,, 6, 7,6 8,,,9,5,,9 6,5 7,5,,5,,6, 5, 6, 7,,5,,,7,,,5,9,,, 9, 8, 5,,7,, 9, 8, 5,6,,7, 9,5 7,,,, 9, 7,,,9,5 9,6,5 6,, 9,,5,, 5,7 8,,, 5,7 8, -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /" 6,,9,,,,,5 8, 6,65 5,6,7,,,, 5 7, 5,,9,,6,,75 9, 9, 8, 6,,9,,5, 9, 7, 5,9,7,9,5,, 8,7 7, 6,,7,9 5,,5 9,75 8,7 7,6 6,,,9,7,, 9, 7,,,5,9,,9, 9,5 7,,7,,,,6 9, 5,6, 5,,85,, 9,5 6,, 5,6,9,7,9 7,, 5,,85,6 7,, 6, 6,, 9,,7 6 9,6 8, 7, 5, 9,,6 6,,5 5, 8,9 7,7,5 5,,, 8, 8, -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /",,,9,9,,, ,6 5, 5, 5,,5,5,, 5,6,,,7,,,, 7,9, 9,7 6,55 8, 6,55 8,, 5,, 5,,,,6, 5 9,5 7,6, 9,75 6, 7,6 6, 7,6, 6,, 5,,,85,,,,,,, 8, 9, 8, 9,,,9 6,,5,7,5,5,, 8, 9, 7, 8,7 5,,9 6,5,5,9,9 8,, 6 7, 7,,7, 8,9,9 5,5 5,5,85 6,,7 7,5 8, 6, 5,, 6,,7 7,5 8, -/" " 7" /" 5" /" " /",5,,,,,, 7P6 7, 5, 5,,5,7,,, 8,6 7, 6, 5, 5,,5,,6.5 to.5 9,9 8,6 6, 6,7,,5, Set:.5,6 8,7 8, 8, 5,9,,6 roop:.,, 9,7 6,9 5,6,,,,, 7,,,,7, 9, 5,,5 6, 7,5 For optimum performance, regulator should be operated above solid line. For UPSO Models, use only above dashed line P8 5.5" to 8" w.c. Set: 7" roop: " Max. ompound: " w.c. 7P9 8.5" to " w.c. Set: " roop: " w.c. 7P to Set: roop:. 7P to 5 Set: 5 roop: ontact your merican Meter representative for inlet pressures above.

8 " Series apacity ata SFH Gas.6 Specific Gravity For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 7P7,5,,,,6,5 /,5,,,9,,6 5, 9 5,6 5,,,,9,,65,.5" to 6" w.c. 8,9 6, 5,,,,,,6 Set: 6" w.c.,, 8, 5 7, 5,,,9,, roop: " w.c. 6,5,, 8, 6,,,,65 Max. ompound: " w.c. 6,5 5 6,, 9, 6,6,,95 9, 5,7,7 8,,6, 6, 8,5,5, 7,7 5,9 7, 9,6,85,,5 5,85 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 7P8,9,,6,7,, /,,,5,,,6 5,5 75 5,6,,,5,7,,6,5 5.5" to 8" w.c. 8,5 6, 5,,5,6,,,5 Set: 7" w.c.,, 8, 5 5,,,9,, roop: " w.c. 5,7,,5 8, 6,,,,6 Max. ompound: " w.c. 7,5 6, 5 5,,5 9, 6,,,9 9, 9, 5,5, 7,,6, 6, 8,5,,5 7, 5,9 7, 9,6,,,5 5, 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 7P9, 5,,7,,,,,5,7,7,6,,,5 75, 7, 5,7 5,,5,6,,,5 8.5" to " w.c.,5 8,5 7, 5 6,,,,6,, Set: " w.c. 5,,, 8, 6,,,9,6 roop: " w.c. 9, 6, 5 5,, 8, 5,,,9 6 8,, 7,9,, 8, 7,,, 7,, 5,7 9,,,,,,5 5,7 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 7P9,7,5,,,,,,,5,,5, 9, 75, 6, 5,,,,,7,, 8.5" to " w.c.,6 7,6 6, 5 5,6,,6,5,, Set: " w.c. 9,,,6 9, 7, 5,,,,6 roop: " w.c. 9, 6, 5,, 7,9 5,5,7,9 7,7, 9,5 7,,, 7, 5, 9, 5,6, 8,,, 6 7, 9,,5, 5,7 8, For optimum performance, regulator should be operated above solid line. For UPSO Models, use only above dashed line. 8 ontact your merican Meter representative for inlet pressures above.

9 " Series apacity ata SFH Gas.6 Specific Gravity For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /", 8, 5,5 7,7,6 8,,6 6,9,9 5, 5 5 6,5 6,,6, 7,,5 5, 7,9,5, 8,,, 6,5 8,6,5, 8,,,7,5 6, 7,6,,6 7,,5,,,7, 5,6 6,7 9,,5,,,6,9,,,,7 5, 8, For Models With lue Holder Without OPSO For Models With Silver Holder Without OPSO For Models With Silver Holder With OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 7,6 6, 5, 5 5,,6,6,6,,,, 8,9 8, 7,6 5,9,,,6 5,,6 5,, 7,6 5,,7,9 9, 5,,5,5 9,5 7,,, 6,, 9, 5,6, 7,, 6,7, 6 7, 9,,6,5 5,, 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 5,,6,9 5,,7,5,6, 9, 7, 6, 6,5 5,,,9,,,, 9, 5 9, 6, 5,,,,6 8,5,,, 8, 5,,6, 9, 7,5 5,5,, 7,6 5,,6,7,7 7,, 9, 6,, 6,7 5,9,6, 8,9, 8,, 9,,6 5,6, 6, 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /", 7,6,,, 5, 8,,5,, 5, 6,6 8,6, 5 5 6, 5, 6,6 8,,,, 5, 6,6 8,,,,,5, 5, 8,,,5 9,,,5, 5, 8,,,5 9,,,,,6, 6, 8,,9, 75,,,,9,5, 6, 7,5 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 8, 6, 5, 5, 5,,,,,, 8,6 7, 5 5,,,,,5, 9, 8,7 8,7 6,5 5,,, 5,,,, 8, 7, 5,,9 5,6 5,6, 9,5 6,5,5 6 5,5, 8,9,9, 6,,7 7,5 8, 7P.5" to 8" w.c. Set: roop: 6" w.c. 7P to Set: roop:. 7P6.5 to.5 Set:.5 roop:. 7P to Set: roop:.6 7P to 5 Set: 5 roop: For optimum performance, regulator should be operated above solid line. For UPSO Models, use only above dashed line. 9 ontact your merican Meter representative for inlet pressures above.

10 -/" Series apacity ata SFH Gas.6 Specific Gravity " Series apacity ata SFH Gas.6 Specific Gravity 7P / to Set: roop: 6" w.c. 7P to -/ Set: -/ roop: / 7P -/ to 5 Set: 5 roop: 7P 5 to Set: roop: 7P to 5 Set: 5 roop: ll Models With lue Holder -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /" 5,9,5,5,,9,9, 5,7 7,5 6,,7,,5,9,, 8,7 7, 6, 5,9,5,7,5 8,,9, 7, 6,5,,,5,,6 7,9 7,9 7,65 5,,7, 5 7,5, 9,9 8, 5,5,7,,,75, 9,5,5, 8,,, 6,,5, 5,,,, 9, 5,7, 5, 9, 5,7, 5,6,9,,6 7,, 9,, 7,, 6, 6,,5 9,,6 6 6, 9,,6 8, 8, 5,, 5,9, 5,9, 7,,9 7, 8,5 8,5 ll Models With lue Holder -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /" 6, 5,,,,5,, ,5 5,,9,,,,7 9,5 8, 7,5 6,5 5,5,,7,,, 8, 6, 5,,,7,,,6 9, 8, 7,5 5,5,6, 5 9,,7,7 9, 7,5 5,,6, 5,,5,, 8,9 6,,5, 7,,, 9,5 6,,5, 6,5,6,,5 9, 5,7, 5,, 8,9 5,7, 7,7 5,,,9 7,, 9, 6,7, 7,, 8, 7,5,7 9,6,6 6 6, 9,6,6 6,, 5,9, 5,9, 7,, 7, 8,5 8,5 ll Models With lue Holder -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /", 8, 6,6 6,,,,,,7 9, 7,5 6,,,6,,,, 9, 8, 6,7 5,5,, 5 6,,, 8, 6,7 5,,, 6,,,,7 8,,, 6,7,6, 8,7 6,,, 8, 5,,, 9,5 5,5, 8,9 5,5, 9, 5,5, 9,5 7,,9, 6,7, 9,6 5,7, 6,7, 9, 5, 9,,6 6 6, 9,,6 9,, 5,9, 5,9, 7,,6 7, 8,5 8,5 ll Models With lue Holder -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /", 8,5 6, 5,,,,5 5,7 8,7 7, 6, 5,,7,,5,,5 9, 8, 6,6 5,,5,,,, 8, 6,7 5,,5, 6,,5, 9,7 7,7 5,, 7,7 5,, 9, 7, 5,, 7,6 5,,, 6,6, 9, 5,7, 9,5 6,6, 7,, 9,,6 6 8,, 9,,6 7,,7 5,9 7,,7 5,9, 7,, 7, 8,5 8,5 ll Models With lue Holder -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /",9, 8,5 7, 5,9 5,,,,9, 8,9 7,5 6,,5,, 5,,9, 9,5 7,,9, 7,6,6, 9,7 7,,9, 7,9 5,,, 6,, 9, 5,5, 9,5 6,, 8,, 9,,6 6 8,,5 9,,6 9,5,7 5,9 7,6,7 5,9,5 7,,5 7, 8,5 8,5 For optimum performance, regulator should be operated above solid line. For UPSO Models, use only above dashed line. ontact your merican Meter representative for inlet pressures above.

11 merican Meter Regulator Parts SERIES LOW PRESSURE REGULTOR PRESSURE SPRINGS.5" to 6" w.c. 7P7 Red 5.5" to 8" w.c. 7P8 Orange 8.5" to " w.c. 7P9 Yellow.5" to 8" w.c. 7P Green to 7P lue.5 to.5 7P6 rown and lue to 7P rown and Green to 5 7P lack and Green SERIES HIGH PRESSURE REGULTOR PRESSURE SPRINGS.5 to 7P rown and White to.5 7P Purple and White.5 to 5 7P Orange and lack 5 to 7P lack to 5 7P Yellow and Green OPSO SHUTOFF SPRINGS " to 8" w.c. 77P75 Red and Purple to 77P76 Red and rown to 77P77 Purple to 5 77P78 Orange and Yellow 5 to 8 77P79 Orange and Green 8 to * 77P78 Orange and Yellow to * 77P79 Orange and Green *To achieve these ranges, reducing ring 766P must be used. / SERIES REGULTOR ORIFIE SIZES Valve Head Size Part Number -/" and " /" 798P -/" and " " 798P -/" and " /" 798P -/" and " 5" 798P -/" and " /" 798P -/" and " 7" 798P5 -/" and " " 798P6 -/" and " -/" 798P7 These orifices are double-sided and work with both OPSO and non-opso Models. REGULTOR REPIR KITS 799K Valve Seat isc 7P7 ody 7P6 iaphragm 7P ody Screw 7P ody Nut 7P Vent Flapper 76P Vent Flapper Retainer 77P Vent Screen 7P8 Isolation Plate (I..) 7P6 Isolation Plate (O..) 7P57 Valve Plunger 7P9 Valve Head Setscrew 7P6 7P6 7P5 Isolation Plate (I..) 7P78 Gasket 79P87 Gasket 79P9 Kit Services:, M,, 8, 8M, 9 799K** Isolation Plate 7P 7P78 7P57 7P9 Kit Services ll Regulators **For use in units built after January, K7** Valve Seat isc 7P7 ody 7P6 Seal Plug 7P7 iaphragm 7P68 ody Screw 7P ody Nut 7P Vent Flapper 76P Vent Flapper Retainer 7876P5 Vent Screen 7P5 Valve Head Setscrew 7P6 7P6 7P5 Gasket 79P9 Kit Services: 8, 8, 8, 85 **For use in units built prior to pril, K5** Valve Seat isc 7P7 ody 7P6 Seal Plug 7P7 iaphragm 7P ody Screw 7P ody Nut 7P Vent Flapper 76P Vent Flapper Retainer 7876P5 Vent Screen 7P5 Valve Head Setscrew 7P6 7P6 7P5 Gasket 79P9 Kit Services: 8, 8, 8, 85 **For use in units built after pril, K6 Valve Seat isc 7P7 ody 7P6 Seal Plug 7P7 iaphragm 7P ody Screw 7P ody Nut 7P Vent Flapper 777P Vent Flapper Retainer 7876P5 Vent Screen 7P Vent Screen Retainer 7876P Isolation Plate (I..) 7P6 Isolation Plate (O..) 7P57 Valve Plunger 7P9 Valve Head Setscrew 7P6 7P6 7P5 Isolation Plate (I..) 7P8 Kit Services: 8, 8, 8, 8M, 85, 85M,, M, 8, 88, 88M, K Valve Seat isc ody Seal Plug Kit Services ll Regulators 7P7 7P6 7P7

12 merican Meter Regulator ssembly Positions Valve Head Position STNR VENT POSITION Valve Head Position STNR VENT POSITION Valve Head Position STNR VENT POSITION STNR VENT POSITION Valve Head Position Full-Open Regulator apacity For sizing downstream relief valves, use the following formulas to determine the regulator full-open capacity: For critical flow rates For sub-critical flows Q =.5 x P G Key: Q = Maximum capacity of regulator = Orifice constant, see table P = absolute pressure (a) P = Outlet absolute pressure (a) h = ifferential pressure (P - P ) G = Specific gravity of gas Q = P h G Orifice /" " 6 /" 5" 6 /" 8 7", ",5 -/",5 STNR VENT POSITION Regulator ssembly Number VLVE HE POSITION * VLVE HE POSITION OPSO VENT POSITION ** ** ** * FOR MOELS USING OPSO ONLY. ** UNLESS OTHERWISE SPEIFIE, VLVE HE POSITION "" WILL E SUPPLIE. STNR VENT POSITION Shipping Weights Net Wgt. escription (Lbs.) -/" x -/" Screwed * 9-/ -/" x -/" Screwed 88 -/ -/" x -/" Screwed * 5-/ -/" x -/" Screwed 8 7-/ " x " Screwed * 9-/ " x " Screwed 88 -/ " x " Screwed * 5-/ " x " Screwed 8 7-/ * ll Models except OPSO. For Flanged Models add -/ lbs. Ordering Information. Model number.. Size of connection: screwed or flanged.. and outlet pressures.. Volume in scfh. 5. Kind of gas and specific gravity. 6. ssembly position. 7. Orifice size. 8. OPSO spring part numbers, if required. omplete Family of Gas Measurement, Pressure Regulation, and Testing Systems Turbine Gas Meters High-performance meters provide accurate measurement of highvolume gas flow. Turbines are available from " to " line sizes and line pressures up to g. See bulletin S 5 for more information. Rotary Gas Meters RPM Series Rotary Meters are designed for commercial and industrial loads to provide accurate flow measurement and outstanding performance in the most adverse conditions. See bulletin S 55 for more information. iaphragm Meters merican Meter s compact, lightweight, aluminumcase meters are designed to provide positive displacement accuracy for industrial or commercial loads. See bulletin S 5 for more information. Pilot-Loaded Regulators PFM industrial regulators are designed for applications requiring medium-to-high capacity, extremely precise outlet-pressure control, and fast response to changing loads. See bulletin S 855 for more information. merican Meter ompany is committed to a program of continuous quality enhancement. ll equipment designed and manufactured by merican Meter ompany benefits from the company s quality assurance standards, which are approved to ISO 9 or ISO 9. merican Meter ompany has a program of continuous product development and improvement; and, therefore, the information in this bulletin is subject to change or modification without notice. MERIN METER Welsh Road uilding One Horsham, P 9- U.S.. Phone: 5- Fax: 5-89 Website: americanmeter.com NIN METER 75 Industrial Road ambridge, Ontario, NH R7 anada Phone: 877/6-66 (toll free) Phone: 59/65-9 Fax: 59/65-97 Website: canadianmeter.com Printed in U.S.. ore 5 5/

Industrial Regulator Series 1800/2000 Instructions and Parts List

Industrial Regulator Series 1800/2000 Instructions and Parts List IMP 8740.3 Industrial Regulator Series 1800/2000 Instructions and Parts List AMC Quality System QMI is Accredited by: ISO 9002 Certified Dutch Council for Accreditation Instructions: Industrial Regulator

More information

1800C and 1800C-HC Series Service Regulators. Technical Bulletin

1800C and 1800C-HC Series Service Regulators. Technical Bulletin and -H Series Service Regulators Technical Bulletin and -H Series Service Regulators 0 Elster American Meter The Series pressure regulators are designed to control natural gas, air, nitrogen, carbon dioxide,

More information

Model 143-6 Residential Service Regulators. R-1303 Rev. 4

Model 143-6 Residential Service Regulators. R-1303 Rev. 4 Model 4-6 Residential Service Regulators R-0 Rev. 4 Model 4-6 Service Regulators equal outstanding performance, utility, and dependability with value. Best Buy, By Far The 4-6 Service Regulator The 4-6

More information

B34 Series Regulator Commercial and Industrial Regulator

B34 Series Regulator Commercial and Industrial Regulator Gas B34 Series Regulator Commercial and Industrial Regulator Applications Appropriate for many commercial and industrial uses such as gas engines, burners, furnaces and boilers. The rapid response of the

More information

Equipment Options Advantages and Disadvantages ALABAMA NATURAL GAS ASSOCIATION. Darin L. Moore, P.E. Elster American Meter

Equipment Options Advantages and Disadvantages ALABAMA NATURAL GAS ASSOCIATION. Darin L. Moore, P.E. Elster American Meter Equipment Options Advantages and Disadvantages ALABAMA NATURAL GAS ASSOCIATION Darin L. Moore, P.E. Elster American Meter KNOWLEDGE, PLANNING AND IMPLEMENTING REDUCES RISK KNOW THE TYPES OF OVERPRESSURE

More information

B34 Commercial & Industrial Regulator. Advanced Metering and Regulation Technology at Work.

B34 Commercial & Industrial Regulator. Advanced Metering and Regulation Technology at Work. IMAC Systems, Inc. 90 Main Street, PO Box 1605 Tullytown, PA 19007 Tel. 1-800-955-4GAS (215) 946-2200 Fax:(215) 943-2984 www.imacsystems.com B34 Commercial & Industrial Regulator Advanced Metering and

More information

043 Service Regulator

043 Service Regulator The 04 Service Regulator is designed to handle a variety of small loads. Use the 04 for industrial or commercial applications. This regulator can also be used for standard residential services: boilers,

More information

Gas Pressure Regulator Series BD 260

Gas Pressure Regulator Series BD 260 Gas Regulator Series BD 260 For Commercial and Industrial Facilities. The BD 260 gas pressure regulator is ideal for deployment at offtake stations in gas systems as well as commercial and industrial facilities.

More information

Types 66R and 66RR Low-Pressure Relief Valves

Types 66R and 66RR Low-Pressure Relief Valves November 2009 Types 66R and 66RR Low-Pressure Relief Valves W1953 W1908 TYPE 66R RELIEF VALVE TYPE 66RR RELIEF VALVE Figure 1. Typical Constructions Introduction Types 66R and 66RR low-pressure throttling

More information

1805 Series Relief Valves

1805 Series Relief Valves October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications May 2016 W8962 Figure 1. Type EZL Pressure Reducing Regulator Features Main Diaphragm The main diaphragm is Nitrile (NBR)

More information

Gas Pressure Regulator Series BD 273

Gas Pressure Regulator Series BD 273 Gas Pressure Regulator Series BD 27 For Special and Indoor Applications. The BD 27 gas pressure regulator is a product series for gas transmission and distribution in offtake stations in commercial and

More information

MODEL 201 225LP 225LP2 225LP4 Safety Relief Valves

MODEL 201 225LP 225LP2 225LP4 Safety Relief Valves Edition GDRV.06 BRYAN DONKIN RMG CANADA LIMITED Serving the Gas Industry WORLDWIDE Applications Specifically designed to protect the downstream system or equipment from over pressure conditions by discharging

More information

OBSOLETE DOCUMENT. CS400 Series Commercial/Industrial Pressure Reducing Regulators. CS400 Series. Instruction Manual Form 5833

OBSOLETE DOCUMENT. CS400 Series Commercial/Industrial Pressure Reducing Regulators. CS400 Series. Instruction Manual Form 5833 Instruction Manual Form 5833 March 2009 Commercial/Industrial Pressure Reducing Regulators Type CS403: CS400 with Integral Monitor Module! Warning Failure to follow these instructions or to properly install

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

Commercial & Industrial Propane Regulators and Meters

Commercial & Industrial Propane Regulators and Meters Commercial & Industrial Propane Regulators and Meters Master Distributor for First Stage Regulators P32* Field adjustable 60 Mesh screen on inlet 1/4 FNPT 250 PSI Excellent stability P37* Patented balance

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

R-1350 Rev. 6. Model 441-S Low Pressure Regulators

R-1350 Rev. 6. Model 441-S Low Pressure Regulators R-1350 Rev. 6 Model 441-S Low Pressure Regulators T H E G A S I N D U S T R Y The Sensus Model 441-S is a balanced valve, spring type gas pressure regulator. It is a general purpose unit that is manufactured

More information

289 Series Spring-Loaded Relief Valves

289 Series Spring-Loaded Relief Valves October 14 89 Series Spring-Loaded Relief Valves W187_1 W1871 TYPE 89L 1 NPT TYPES 89H AND 89HH W187 NPT TYPE 89H W187_ TYPES 89U AND 89A Figure 1. Types 89H, 89L and 89U Relief Valves Introduction The

More information

RB4000 Commercial & Industrial Regulator

RB4000 Commercial & Industrial Regulator RB4000 Commercial & Industrial Regulator Advanced Metering and Regulation Technology at Work Features Direct acting spring-loaded pressure regulator Balanced Valve Design Fluids: Natural gas, propane,

More information

Fundamentals of Pressure Relief Valves

Fundamentals of Pressure Relief Valves Fundamentals of Pressure Relief Valves Ken Ludvigsen Regional Manager Emerson Process Management Regulator Technologies Inc. 310 E. University Dr. McKinney, Texas USA 612 Fundamentals of Pressure Relief

More information

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology Vacuum Applications Vacuum regulators and breakers are widely used in process plants. Conventional regulators and relief valves might be suitable for service if applied correctly. This section provides

More information

MODEL 240 GAS PRESSURE REGULATOR

MODEL 240 GAS PRESSURE REGULATOR Edition GD240.06.USA BRYAN DONKIN RMG USA Serving the Gas Industry WORLDWIDE Applications Primarily utilized for residential, commercial and industrial applications For natural gas and all non-corrosive

More information

FUNDAMENTAL PRINCIPLES OF DIAPHRAGM METERS. Robert Bennett American Meter Company

FUNDAMENTAL PRINCIPLES OF DIAPHRAGM METERS. Robert Bennett American Meter Company FUNDAMENTAL PRINCIPLES OF DIAPHRAGM METERS Robert Bennett American Meter Company INTRODUCTION The first gas company in the U.S., The Gas Light Company of Baltimore, Maryland, founded in 1816, struggled

More information

P630 High Flow Gas Regulator

P630 High Flow Gas Regulator P630 High Flow Gas Regulator Stainless Steel Internals are Standard Steel Units comply with NACE MR0175 Durable Powder Coated Exterior Wide Range of Flow Capacities The P630 is a spring loaded, direct-operated

More information

Type 99 Pressure Reducing Regulator

Type 99 Pressure Reducing Regulator Bulletin 7: February 2016 Type Pressure Reducing Regulator W27 W76 Figure 1. Typical Type Regulator Introduction The Type gas regulators provide a broad capacity for controlled pressure ranges and capacities

More information

J48. Low Pressure Gas Pressure Regulator

J48. Low Pressure Gas Pressure Regulator J48 Low Pressure Gas Pressure Regulator Commissioning Instructions General Arrangements Parts Lists Maintenance Instructions For: J48 MKII Regulator ¾" - 2", J48 MKII Angled Regulator ¾" - 2", J48 MKII

More information

B31 Series Commercial Regulator

B31 Series Commercial Regulator IMAC Systems, Inc. 90 Main Street, PO Box 1605 Tullytown, PA 19007 Tel. 1-800-955-4GAS (215) 946-2200 Fax:(215) 943-2984 www.imacsystems.com B31 Series Commercial Regulator Advanced Metering and Regulation

More information

Governor Gas Regulator

Governor Gas Regulator Governor Gas Regulator ANSI Z21.80a CSA 6.22a-2005 Inlet Pressures 25" W.C. to 5 PSIG Pressures To 2 PSIG Governor Introduction Pietro Fiorentini s Governor line of gas regulators are designed to comply

More information

Service and installation must be performed by a trained/experienced service technician.

Service and installation must be performed by a trained/experienced service technician. CTLOG Service and installation must be performed by a trained/experienced service technician. ll products used with combustible gas must be installed and used strictly in accordance with the instructions

More information

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR

More information

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4

More information

LEVER ACTING DESIGN GAS APPLIANCE PRESSURE REGULATOR

LEVER ACTING DESIGN GAS APPLIANCE PRESSURE REGULATOR LEVER TING DESIGN GS PPLINE PRESSURE REGULTOR S 6. and NSI Z21.18 Design ertified - 25-, 25-5 Maximum Inlet Pressure: NSI Z21.18 ertified - 25-, 25-5...2psi (140 mbar), 5 psi (45 mbar) Maxitrol-tested:

More information

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification... OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3

More information

B42 Series Regulator Residential Regulator

B42 Series Regulator Residential Regulator Gas B42 Series Regulator Residential Regulator Applications Consistent pressure reduction of gas for typical domestic and light commercial applications. Description > The B42 is a spring loaded self-operated

More information

T205VB Series Tank Blanketing Vacuum Breakers

T205VB Series Tank Blanketing Vacuum Breakers Instruction Manual T205VB Series December 2013 T205VB Series Tank Blanketing Vacuum Breakers Table of Contents Introduction...1 Specifications...2 Principle of Operation...2 Installation...5 Startup, Adjustment

More information

ON-OFF FLOAT CONTROL VALVE

ON-OFF FLOAT CONTROL VALVE ON-OFF FLOAT CONTROL VALVE (4 and Smaller) /08 Schematics Opens when float reaches low level stop Closes when float reaches high level stop Low and High Level stop collars are adjustable P/L X Standard

More information

PRESSURE REGULATOR LOW PRESSURE BACK PRESSURE

PRESSURE REGULATOR LOW PRESSURE BACK PRESSURE PRESSURE REGULATOR LOW PRESSURE BAK PRESSURE APPLIATIONS: ontrol 3 to 20 psig back pressure on low pressure vessels and vent lines of separators, treaters, compressors, and gas gathering systems. EATURES:

More information

RB1700 Series Commercial Regulator

RB1700 Series Commercial Regulator RB1700 Series Commercial Regulator Advanced Metering and Regulation Technology at Work Model Designations Pressure Regulator RB 1700 Benefits -Accurate regulation -Fast response -Easy maintenance -Compact

More information

CL231 Series Regulator Commercial Regulator

CL231 Series Regulator Commercial Regulator Gas CL231 Series Regulator Commercial Regulator Applications The CL231 regulator is designed primarily for use in medium size commercial and industrial installations requiring highly accurate pressure

More information

Vickers. Service Data. Vane Pumps. Vane Type Triple Pump (F3) 3525VQSV10* ***** ******* 20* Released M 2494 S

Vickers. Service Data. Vane Pumps. Vane Type Triple Pump (F3) 3525VQSV10* ***** ******* 20* Released M 2494 S Service ata Vickers Vane Pumps Vane Type Triple Pump (F3) 3525VQSV10* ***** ******* 20* Released 08 01 95 M 2494 S 10 SE rated capacity (V10 cover end cartridge) USgpm Rotor Vane Kit Ring Pin Pin olt olt

More information

J78. Low Pressure Gas Pressure Regulator

J78. Low Pressure Gas Pressure Regulator J78 Low Pressure Gas Pressure Regulator Commissioning Instructions General Arrangements Parts Lists Maintenance Instructions For: J78R Regulator ½, ¾" & 1, J78RS Regulator ½, ¾" & 1" 2 J78: Commissioning

More information

PRESSURE REGULATORS GAS LOW PRESSURE PRESSURE REDUCING

PRESSURE REGULATORS GAS LOW PRESSURE PRESSURE REDUCING GAS LOW PRESSURE PRESSURE REDUCING APPLICATIONS: Low pressure regulator for maintaining vapor pressure on storage tanks, controlling compressor by-pass for gas recirculation and maintaining low pressure

More information

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9) Form TI420-KIT A Watts Industries Co. TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9) DESCRIPTION Thank you for purchasing a Powers kit. The Powers kit you

More information

CHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192.

CHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192. CHAPTER II REGULATOR AND RELIEF DEVICES This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192. BASIC CONCEPT In understanding

More information

Basket Strainers. Flow Rate Vs. Pressure Drop (Clean Screen) Basket Strainers - Flanged Basket Strainers - Threaded

Basket Strainers. Flow Rate Vs. Pressure Drop (Clean Screen) Basket Strainers - Flanged Basket Strainers - Threaded asket Strainers feature top removal of the screen. The screen is in the form of a basket, with a lifting handle, so that all particulate captured and retained by the screen can be easily removed for disposal.

More information

Regulator Product Line

Regulator Product Line Gas Regulator Product Line Overview Designed for accuracy, dependability and safety, Itron gas pressure reducing regulators are for use in natural gas distribution systems as well as industrial applications

More information

B&G Circuit Setter RF Balancing Valves

B&G Circuit Setter RF Balancing Valves B&G Circuit Setter RF Balancing Valves THE RF CIRCUIT SETTER BALANCING VALVES ARE FOR LOW-FLOW APPLICATIONS This Bell & Gossett valve is a triple-purpose balancing instrument with standard sweat (copper)

More information

L627 High Flow LP Gas Regulator

L627 High Flow LP Gas Regulator High Flow LP Gas Regulator Wide of Flow Capacities Durable Powder Coated Exterior Installation Versatility The is a spring loaded, direct-operated LP Gas regulator for high pressure applications in the

More information

1900/P Series. Consolidated * Valves. Safety Relief Valve

1900/P Series. Consolidated * Valves. Safety Relief Valve GE Oil & Gas Technical Specifications 11/2014 Consolidated * s 1900/P Series Safety Relief The 1900/P Safety Relief is designed to be highly adaptable to meet numberous application requirements. Table

More information

Accelerator Model D-2

Accelerator Model D-2 November 25, 2013 Dry 111a 1. description The Viking is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve. An accelerator

More information

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series Gas Appliance Pressure Regulators with integrated gas filter FRI/6 Series CSA Certified ANSI Z21.18 / CSA 6.3 Gas Appliance Pressure Regulator File # 1135455 EU Gas Appliance Directive EN 88-1 CE-0087

More information

B. Provide low pressure steam via a two-parallel full capacity pressure reducing stations with 33/67% pressure reducing valves (PRV s).

B. Provide low pressure steam via a two-parallel full capacity pressure reducing stations with 33/67% pressure reducing valves (PRV s). SECTION 23 22 00 STEAM AND CONDENSATE PIPING AND PUMPS PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish

More information

B34S Series Regulator Medium Duty Commercial and Industrial Regulator

B34S Series Regulator Medium Duty Commercial and Industrial Regulator B34S Series Regulator Medium Duty Commercial and Industrial Regulator Appropriate for many commercial and industrial uses such as gas engines, burners, furnaces and boilers. The rapid response of the B34

More information

AURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM

AURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM UROR 1030 ND 1040 Series SUCTION DIFFUSERS, COMINTION ND TRIPLE DUTY VLVES WWW.URORPUMP.COM UROR 1030 ND 1040 Series Suction Diffusers, Combination and Triple Duty Valves Designed for Direct Mounting on

More information

B38 Series Commercial & Industrial Regulator

B38 Series Commercial & Industrial Regulator B38 Series Commercial & Industrial Regulator Advanced Metering and Regulation Technology at Work Features Interchangeable orifice 78 in 2 of diaphragm area Spring-loaded internal relief valve assembly

More information

EZR Series Pressure Reducing Regulator

EZR Series Pressure Reducing Regulator EZR Series Pressure Reducing Regulator November 2015 Robust Quiet Operation Thoroughly Tested Exceptional Design W7399 TYPE EZR REGULATOR Internally Actuated W8136 TYPE EZROSX WITH INTEGRAL SLAM-SHUT DEVICE

More information

Type 99 Pressure Reducing Regulator

Type 99 Pressure Reducing Regulator Instruction Manual Form 589 Type 99 February 2016 Type 99 Pressure Reducing Regulator! WARNINg Since a pilot-operated regulator is constructed of both a pilot and a main valve, care should be used not

More information

6350 Series Pilots for Pilot-Operated Pressure Reducing Regulators

6350 Series Pilots for Pilot-Operated Pressure Reducing Regulators Instruction Manual Form 5860 October 2009 6350 Series Pilots 6350 Series Pilots for Pilot-Operated Pressure Reducing Regulators bellows valve plug spring balanced valve plug bleed hole removable vent unbalanced

More information

133 Series Direct-Operated Regulators

133 Series Direct-Operated Regulators 133 Series Direct-Operated Regulators Bulletin 71.1:133 June 13 W1327/IL W63/IL TYPES 133H, 133L, AND 133Z REGULATORS TYPE 133HP REGULATOR Figure 1. 133 Series Direct-Operated Regulators Features Wide

More information

Maintenance Information

Maintenance Information 876124 Edition B April 2013 Pneumatic Filters, Regulators, Lubricators, Filter/Regulators and Combination Units 849XXX Maintenance Information Save These Instructions Product Description The air line Filters,

More information

APCO COMBINATION AIR VALVES

APCO COMBINATION AIR VALVES BULLETIN 3 JULY 014 APCO COMBINATION AIR VALVES Series 1800 Custom Combination Duplex Body Series 140C Standard Combination Single Body www.dezurik.com APCO Combination Air Valves Single Body Double Orifice

More information

Type Y692 Low-Pressure Gas Blanketing Regulator

Type Y692 Low-Pressure Gas Blanketing Regulator Instruction Manual Form 5347 Type Y692 August 2009 Type Y692 Low-Pressure Gas Blanketing Regulator! Warning Failure to follow these instructions or to properly install and maintain this equipment could

More information

Free Floating Lever Drain Traps For Loads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar)

Free Floating Lever Drain Traps For Loads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar) Free Floating ever rain Traps For oads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar) iquid rainers Table -14. Maximum Operating Pressures for Handling ifferent Specific Gravity iquids

More information

PRESSURE REGULATORS GAS BACK PRESSURE

PRESSURE REGULATORS GAS BACK PRESSURE PRESSURE REGULATORS GAS BAK PRESSURE APPLIATION: Vent lines on oil separators, flow treaters, compressor stations, gas gathering systems. PRESSURE RANGE: ast Iron: 5 psig to 125 psig Ductile Iron: 10 psig

More information

Float and Thermostatic Traps Series H, C and X

Float and Thermostatic Traps Series H, C and X Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT

More information

Eaton Filtration, LLC

Eaton Filtration, LLC Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual

More information

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED Domestic and Non-Domestic Meter Regulators G940/G941 - Domestic Meter Regulator Domestic regulator offering high performance in a compact unit. Sizes:

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

Auto Reset Gas Solenoid Valves GV-VMR

Auto Reset Gas Solenoid Valves GV-VMR Page 1 of 5 Description The VMR type valve is a fast opening single-stage solenoid valve, normally closed. This type of device is suitable for air or gas blocking and releasing controls, required in gas

More information

167D Series Switching Valves

167D Series Switching Valves June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are

More information

Type 627F Pilot-Operated Pressure Reducing Regulator

Type 627F Pilot-Operated Pressure Reducing Regulator Instruction Manual Form 5282 Type 627F April 2012 Type 627F Pilot-Operated Pressure Reducing Regulator W5607 W5641 Figure 1. Type 627F Pilot-Operated Pressure Reducing Regulators! WARNING Failure to follow

More information

Series VS1000 Vaporizing, Steam Heated, Single Stage Pressure Regulator INSTALLATION AND OPERATION MANUAL

Series VS1000 Vaporizing, Steam Heated, Single Stage Pressure Regulator INSTALLATION AND OPERATION MANUAL Series VS1000 Vaporizing, Steam Heated, Single Stage Pressure Regulator INSTALLATION AND OPERATION MANUAL Part Number 00-15000009 Revision 0 Copyright May 2005 Advanced Pressure Technology ( AP Tech )

More information

REGULATOR TROUBLESHOOTING: A PRACTICAL GUIDE By Keith D. Webb, P.E.

REGULATOR TROUBLESHOOTING: A PRACTICAL GUIDE By Keith D. Webb, P.E. REGULATOR TROUBLESHOOTING: A PRACTICAL GUIDE By Keith D. Webb, P.E. This paper is intended to establish some solutions for common field problems associated with gas pressure regulators. It addresses existing

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,

More information

Type 1190 Low-Pressure Gas Blanketing Regulator

Type 1190 Low-Pressure Gas Blanketing Regulator Instruction Manual Form 5307 Type 1190 April 2012 Type 1190 Low-Pressure Gas Blanketing Regulator! WARNING Failure to follow these instructions or to properly install and maintain this equipment could

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

TABLE OF CONTENTS. Stainless Steel Air Preparation Products

TABLE OF CONTENTS. Stainless Steel Air Preparation Products Stainless Steel Air Preparation Products Monnier offers a line of particulate filters, coalescing filters, regulators and filter/regulators in 316 Stainless Steel. esigned to withstand caustic solutions,

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

B42 Series Regulator. Advanced Metering and Regulation Technolgy at Work

B42 Series Regulator. Advanced Metering and Regulation Technolgy at Work B Series Regulator Advanced Metering and Regulation Technolgy at Work Features Interchangeable aluminum orifice 1. in of diaphragm area Molded deep convolution diaphragm with o-ring seal Plated steel diaphragm

More information

REPLACEMENT PROCEDURE:

REPLACEMENT PROCEDURE: TOOLS REQUIRED TO INSTALL THIS KIT: ITEM DESCRIPTION: A SCREWDRIVER - PHILIPS SIZE # 2 B SCREWDRIVER - FLAT 1/8 WIDE TIP C 7/8 in WRENCH - OPEN TYPE D 9/16 in WRENCH - OPEN TYPE E 1/2 in WRENCH - OPEN

More information

VML. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80. elektrogas.com EE

VML. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80. elektrogas.com EE VML Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 elektrogas.com EE16-0108 VML Safety solenoid valves for gas Slow opening and fast closing type Contents Description.. Features..

More information

Introduction to Regulators

Introduction to Regulators Instrument engineers agree that the simpler a system is the better it is, as long as it provides adequate control. In general, regulators are simpler devices than control valves. Regulators are self-contained,

More information

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose: PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

MUELLER CORPORATION VALVES

MUELLER CORPORATION VALVES MUELLER CORPORATION VALVES 5. Machine inserted corporation stops were developed by Hieronymus Mueller in conjunction with his development of the drilling and tapping machine used to make pressure taps

More information

Before repairing your toilet, you must determine

Before repairing your toilet, you must determine Before repairing your toilet, you must determine which type of toilet you have. Pressurized Toilets If you have a pressurized toilet, it is recommended that you call a licensed plumbing contractor to repair

More information

Self Operated Pressure Control Valves 5953 and 5954

Self Operated Pressure Control Valves 5953 and 5954 Pagina 1 di 8 7C.400-E Ed. 6 IT - 2010 Self Operated Pressure Control Valves 5953 and 5954 Description Fluxotrol self operated pressure control valves are used for the pressure control of liquids, steam

More information

PROFLEX Control Valves

PROFLEX Control Valves PROFLEX Control Valves Globe Control Valves 3-way Control Valves Pneumatic Diaphragm Actuators, Type T Pneumatic Diaphragm Actuators, Type S Pneumatic Screw-in Temperature Controllers Operating Instruction

More information

1301 Series High-Pressure Regulators

1301 Series High-Pressure Regulators 1301 Series High-Pressure Regulators Bulletin 71.1:1301 December 2013 P10 Figure 1. Type 1301F Regulator Features Durable Stainless Steel Diaphragm For high-outlet pressure applications. Spare Valve Disk

More information

Series 830. Direct Acting Steam PRV. Typical Installation. Selection. Other Series 800 Steam Regulators. Series 810 PRV

Series 830. Direct Acting Steam PRV. Typical Installation. Selection. Other Series 800 Steam Regulators. Series 810 PRV Series 8 Direct Acting Series 8 Direct Acting Other Series 8 Regulators Typical Installation Series 8 supply Series 82 Series 8 Safety ale Strainer Series 8 PRV ondensate Series 8 uced Direct Acting PRV

More information

ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.

ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16. ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.4-1998 - Cast Iron Threaded Fittings ASME/ANSI B16.5-1996 - Pipe

More information

Sizing of Independent Pressure Regulators for Large Propane Systems

Sizing of Independent Pressure Regulators for Large Propane Systems SUPPLEMENT 3 Sizing of Independent Pressure Regulators for Large Propane Systems Editor s Note: Supplement 3 provides guidance to designers and installers of larger propane systems over 5, Btu/hr (147

More information

Model 222S (Galvanized receiver optional) AURORA. 220 Series SINGLE STAGE CONDENSATE AND BOILER FEED PUMPS

Model 222S (Galvanized receiver optional) AURORA. 220 Series SINGLE STAGE CONDENSATE AND BOILER FEED PUMPS Model 222S (Galvanized receiver optional) AURORA 220 Series SINGLE STAGE CONDENSATE AND BOILER FEED PUMPS WWW.AURORAPUMP.COM AURORA 220 Series Single Stage Condensate and Boiler Feed Pumps 2 Introduction

More information

VMM. Multiple safety solenoid valve for gas regulating trains DN32 DN50. VMM402AS30

VMM. Multiple safety solenoid valve for gas regulating trains DN32 DN50.  VMM402AS30 VMM Multiple safety solenoid valve for gas regulating trains DN DN www.elektrogas.com VMMAS0 Certified Quality System Printed in Italy - EE1/05 VMM Multiple safety solenoid valve for gas regulating trains

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 235-11 Pressure Regulator Pressure build-up regulator Valve opens when the upstream pressure drops Pressure reducing valve Valve closes when

More information

Pressure Control for CO 2

Pressure Control for CO 2 Control for CO 2 A range of pressure control valves are available for gaseous CO 2 use in high flow applications. The CO 2 source can be a bulk liquid CO 2 storage tank, a high pressure tank or manifold

More information

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications Instruction Manual Form 5753 Type HSR February 014 Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications P154 TYPE HSR ANGLE BODY P175 TYPE HSR STRAIGHT Figure 1.

More information

Type Y692 Gas Blanketing Regulator System

Type Y692 Gas Blanketing Regulator System Bulletin 7:Y69 Type Y69 Gas Blanketing Regulator System November 14 W930-1 Figure 1. Type Y69 Low-Pressure Gas Blanketing Regulator Introduction An Accu-Pressure Gas Blanketing Regulator System reduces

More information

Technical Data RV

Technical Data RV Technical Data RV.226.00.0101 Technical Data Introduction The Series 226R & 226HR are Low Pressure, Direct Acting, diaphragm operated Relief Valves. Service Conditions Size Model Max. Inlet Outlet Pressure