1 Reliance Electric VTAC 7 Specifications Volts Volts VARIABLE FREQUENCY DRIVES This specification should be used to detail the requirements for a 1 through 400 HP at 460 Volts and 1 through 100 HP at 208 Volt AC Variable Frequency Drive (VFD). 1.0 GENERAL A single manufacturer of both motors and drives shall provide, coordinate, and start-up a drive package to ensure both proper application of the motor to the control and of the drive package to the driven load. The Variable Frequency Drive shall be manufactured by Reliance Electric Company. A. The standard Variable Frequency Drive (VFD) and all the optional modifications shall mount within a packaged NEMA 1 or NEMA 12 ( Volts, Volts) enclosure. B. Motor and VFD shall be of the same manufacturer. C. VFD shall be current rated at 8 khz carrier frequency for VFD's HP and 4 khz for VFD's HP. In cases where motor audible noise is not critical to the driven equipment, 4 khz may be used in drives above 60 HP. All HP ratings shall meet or exceed Table of the NEC, 3 Phase Motor Full Load Currents. HP, Maximum Current, and Rated Voltage shall appear on the drive nameplate. D. VFD shall not generate damaging transistor pulses at lead lengths up to 500 feet greater than limits set by NEMA MG1 section Minimum rise time at 500 feet shall be.1 microseconds and peak voltage shall remain under 1600 volts per this standard. Motors shall also be designed to withstand this rise time and peak voltage level. 1.1 BASIC DESCRIPTION The VFD shall be a fully digital PWM using very large scale integration (VLSI) techniques as well as surface-mount technology for increased reliability. The VFD shall use two 32-bit microprocessors with 12-bit resolution to allow stepless motor control from 0.1% to 110% of motor base speed.

2 All programmable settings shall be held in non-volatile memory and shall not be affected by power outages, brownouts, power dips, etc. The VFD shall have initial programmable settings intact from the factory without the need of battery backup. the VFD shall not need to be programmed at the job site prior to being able to run a motor, but shall be ready to run a motor as soon as power connections are made. Programming at the job site to accommodate specific local applications requirements, such as frequency avoidance and preset speeds shall be available to the user. VFD multiple motor operation at the same frequency and speed shall be possible as long as the sum of the connected motor full load sine wave currents are less than or equal to 90% of the VFD maximum continuous current rating. Supply and Return Fan horsepower requirements are as stated in schedule documents. All high voltage components within the enclosure shall be isolated with steel or polycarbonate covers. 1.2 CODES/STANDARDS VFD and options shall be c UL* 508 listed. NEMA 12 enclosed VFD shall be UL ä approved for mounting in conditioned air ducts and plenums (UL 1995). The drive and options shall comply with the applicable requirement of the latest standards of ANSI, NEMA, National Electric Code NEC, NEPU-70, IEEE , FCC Part 15 Subpart J, CE 96. VFD manufacturer shall be ISO 9001 certified. 1.3 EXPERIENCE The manufacturer of the VFD described in this specification shall have a minimum of 20 years experience in the design, construction and application of adjustable frequency controls and motors. 1.4 QUALITY ASSURANCE The VFD shall be subject to but not limited to the following quality assurance controls, procedures and tests. A. The VFD's shall be designed, manufactured, and tested in the United States of America. Compliance with this specification shall be stated in writing at time of bid. A minimum 80 % US. content will be considered acceptable. B. During the Design Engineering process for the VFD the following quality assurance controls, procedures and tests shall be implemented. 1. Each new product design shall undergo a 4000 hour pre-production burn-in test. Up to ten units may be used to accumulate this entire time. Each unit shall be temperature cycled between 0 and 50ºC during this time period. 2. Digital integrated circuits shall undergo functional and reliability tests. Regulator circuits must use reliable and compact surface mount construction. These circuits

3 shall be 100% tested on computer controlled systems. Test equipment must be documented, controlled and calibrated to ISO 9001 standards. 3. Each drive power circuit shall be tested under motor load conditions. While loaded, the output waveform shall be monitored for correct PWM algorithm. Short circuit testing shall be done to UL standards and an AIC rating placed on each controller nameplate. 4. All components utilized with the basic VFD like contactors, overload relays, pushbuttons, pilot devices, and other control devices shall be UL. recognized. These components shall be manufactured by Allen Bradley Company. C. After initial product quality assurance testing, each drive shall be subjected to the following quality control procedures. 1. Every VFD shall be functionally tested under motor load. During this load test the VFD shall be monitored for correct phase current, Phase voltages, and motor speed. Correct Current Limit operation shall be verified by simulating a motor overload. 2. A HYPOT voltage test shall be performed using at least 2715 VDC. Leakage currents during this test must not exceed 100 micro amps. This test insures proper grounding procedures have been followed during manufacturing. 3. Verification of proper factory presets by scrolling through all parameters shall be performed to ensure proper microprocessor settings. The computer port should also verify that the proper factory settings are loaded correctly in the drive. 4. All options shall be functionally tested including operation of a motor in the Bypass mode if supplied. Proper heater coil installation in motor overload, if supplied, shall be verified. D. Quality control systems shall conform to the ISO9001 standard. Under this system, quality assurance for design/development, production, installation and servicing of the proposed manufactures equipment shall be certified ISO9001. Written certification of conformance to this standard shall be supplied at time of bid. 1.5 SERVICE A. The VFD manufacturer shall maintain and staff world-wide service centers. The manufacturers shall have the ability to test both the controller and the motor in these service centers. 1. Start-up shall be included for each VFD provided. 2. The service engineers shall be employed by the manufacturer or be certified by the manufacturer and provide start-up service including physical inspection of drive and connected wiring and final adjustments to meet specified performance requirements. B. Training shall be available on site by employees of the manufacturer and shall be in addition to the start-up serviced. Training shall include system concepts and basic troubleshooting. C. A reasonable supply of spare parts must be kept available for the VFD to meet ordinary repair requirements for the immediate future. In addition, spare parts shall be available within 24 hours of notification through a local Service Center, by the user.

4 2.0 VARIABLE FREQUENCY DRIVE The VFD manufacturer shall provide, at minimum the basic features, adjustments, general options and modifications as specified below. 2.1 BASIC FEATURES The VFD shall have the following basic features: A. All HP 460 Volt VFD's current ratings shall be at 8 khz carrier frequency. No derating of the drive shall be required due to increasing this switching frequency for motor noise reduction An alternate 4 khz HP 460 Volt Wall Mounted Drive may be supplied where motor audible noise is not critical to the installation. VFD's from HP 460 Volt shall maintain current ratings at 4 khz. VFD's from HP 208 Volt shall be rated at 8 khz carrier frequency. Drives that automatically reduce the carrier frequency as load is increased shall not be supplied. Operator controls shall be mounted on the door of the cabinet and consist of a membrane command center which allows manual stop/start, speed control, local/remote status indication, manual or automatic speed control selection, and run/jog selection. In addition, the command center will serve as a means to configure controller parameters such as Min Speed, Max Speed, Acceleration and Deceleration times, Volts/Hz ratio, Torque Boost, Slip Compensation, Overfrequency Limit, and Current Limit. Potentiometers will not be allowed for these settings. The controller shall have an internal means of deactivating keypad parameter adjustments to eliminate unauthorized data entry. B. A slip compensation circuit for accurate 1% speed regulation without the need of a tachometer. C. Adjustable DC braking that is programmable from the command center settable in both amplitude and duration. D. An electronic overload circuit designed to protect an AC motor operated by the VFD output from extended overload operation on an inverse time basis. This Electronic overload shall be ULä and NEC recognized as adequate motor protection. No additional hardware such as motor overload relays or motor thermostats shall be required. E. Automatic and manual torque boosts that are settable within the control to accelerate high inertia fan and pump loads. F. An LED display mounted on the door of the cabinet that digitally indicates: 1. Frequency output 2. Voltage output 3. Current output 4. Motor RPM 5. Input kw 6. Elapsed Time 7. Time Stamped Fault Indication 8. DC Bus Volts

5 G. The capability of starting into a rotating load regardless of direction without the need of a time delay upon a start command. H. Relay contacts for remote indication of drive fault or motor running for inter-wiring to other user supplied devices. I. An automatic restart circuit which is settable by number of restart attempts and time interval between restarts. J. Three critical frequency avoidance bands, which can be programmed in the field, enable the controller to avoid resonate frequencies of the driven equipment. Each critical frequency avoidance band shall have a bandwidth adjustable via keypad entry of up to 10 Hz. K. Eight programmable preset speeds which will force the VFD to a preset speed upon a user contact closure. This feature shall be set digitally by entering data via the door mounted membrane command center. These shall be utilized for user specified purge functions. L. The VFD shall have the capability of riding though power dips up to 10 seconds without a controller trip depending on load and operating condition. In this extended ride through, the drive shall use the energy generated by the rotating fan as a power source for all electronic circuits. M. Multiple Volts/Hz patterns settable in one Hz increments. N. Jog speed selection. O. RS232 Port for Configuration, Control, and Monitoring. P. An isolated electrical follower capability shall enable the Adjustable Frequency Controller to follow a 0-20mA, 4-20mA or 0-4, 0-8, 0-10 volt DC grounded or ungrounded speed signal. Q. A isolated 0-10 V or 4-20 ma output signals for computer controlled feedback signals shall be selectable for speed or current. R. For ultra-smooth acceleration and deceleration capabilities, the drive shall have a preprogrammed "S" curve ramp which can be activated locally. S. Flux Vector PWM operation with "trip free" circuitry to eliminate nuisance faults. T. IGBT transistors with a selectable carrier frequency between 4 and 8 khz 2.2 PROTECTIVE CIRCUITS AND FEATURES The VFD shall include the following protective circuits and features: 1. Motor current exceeds 200% of drive continuous current rating. 2. Output phase-to-phase short circuit condition.

6 3. Total ground fault under any operating condition. 4. High input line voltage. 5. Low input line voltage. 6. Low input line voltage. 7. Loss of input or output phase. 8. External fault. (This protective circuit shall permit wiring of remote N.C. safety contact to shut down the drive). User supplied end switches, thermal switches, firestats, freeze-stats inputs will be connected to this VFD supplied circuit. 9. Metal oxide varistors for surge suppression shall be provided at the VFD input terminals. 2.3 ADJUSTMENTS The following adjustments shall be provided: A. Maximum frequency (1-120Hz) with factory setting at 60Hz. B. Minimum frequency (5 to 60Hz). C. Acceleration (0.1 to seconds). D. Deceleration (0.1 to seconds). E. Volts/Hz ratio factory set for 460 Volts at 60Hz or 208 Volts at 60 Hz. F. Current limit (50 to 110%) drive continuous rating. 2.4 SERVICE CONDITION The VFD shall be designed and constructed to operate within the following service conditions: A. Suitable for continuous operation at an ambient temperature of 0ºC to 40ºC, elevation up to 3300 feet altitude with a relative humidity to 95% non-condensing. B. AC line variation of -10% to + 10% Voltage and +/-5 Hz Frequency. C. AC line distribution system capacity shall not exceed 30,000 Amps symmetrical available fault current. 2.5 GENERAL OPTIONS AND MODIFICATIONS The following options shall be included as specified in the document: 1. The energy efficient motor manufacturer shall performance-match and guarantee full nameplate horsepower and speed when operated on the specified VFD and also

7 provide as a minimum the mechanical design, electrical design and basic features as follows: 2. All motors shall conform to the latest applicable requirements of NEMA, IEEE, ANSI and NEC standards. 3. Motors shall be of an energy efficient design meeting NEMA efficiency table or a premium efficient design. 4. Motors shall be designed for continuous duty operation, NEMA design B. 5. Open Drip Proof Motors and Totally Enclosed Motors to be furnished with Class F insulation. 6. Motor Insulation System shall conform to all of the requirements of NEMA MG1 part 31 section for peak voltage withstand capability. 7. Stainless steel nameplates with: A. NEMA efficiency index nominal efficiency (MG b) B. AFBMA bearing numbers C. Lubrication instructions B. Isolation Transformer in a NEMA 1 enclosure, for separate mounting, for use on threephase 60Hz input power of the voltage specified to provide three-phase, 60Hz output for the Variable Frequency Drive. C. Complete Contactor ByPass shall be provided to allow motor to be safely transferred from VFD output to the AC line, or from the AC line to the VFD, while the motor is at zero speed. The contactor ByPass shall utilize two motor contactors electrically interlocked. One contactor is to open and close the connection between the VFD output and the motor. The other contactor will open and close the connection between the ByPass power line and the motor, providing "across the line" starting. Motor protection is to be provided in the "ByPass" mode by a bi-metallic Class 20 Smart Motor Protection adjustable overload relay. Relay control logic shall also be included within the VFD enclosure to allow the same "START/STOP" command to operate the motor in either mode. The relay logic shall be 115 Volts. The ByPass circuit shall include a second disconnect installed in the VFD to provide the ability to safely troubleshoot and test the controller, both energized and de-energized, while the motor is running in the "ByPass" mode. A contact closure shall be provided to indicate that the drive is in the "ByPass" mode. A Remote/Local selector switch shall also be provided to transfer control from the keypad to user wired signals. Form "C" Normally Open and Normally Closed contacts shall be provided for both Run and IET/Drive Stopped. The entire ByPass option shall be packaged with the controller enclosure and be mechanically isolated from the VFD. D. Input line fuses shall provide protection for the input rectification circuit using Class J fuses with interrupting rating of 200,000 AIC. The series interrupting rating of the VFD and fuses shall be a minimum of 30,000 AIC and shall be stated in the VFD Instruction Manual as required by UL E. A main input disconnect shall mount within the standard NEMA 1 or NEMA 12 enclosure for positive power disconnect of the VFD. It shall have the capability for door padlocking. F. A three phase 3% impedance Input Line Reactor shall be provided to minimize drive harmonics on the AC line and protect the drive from damaging electrical system transients. G. In units from 1-40 HP a door interlocked main input disconnect shall be provided. This disconnect shall also increase the short circuit interrupting capacity from 30,000 to 85,000

8 amps symmetrical fault current. This high fault current option shall be UL listed and suitable for use on distribution systems feeds up to 4,000 KVA with 5% minimum impedance. To rate the drive at 85,000 AIC, a three phase Line Reactor must be provided with the appropriate disconnect. H. Provide harmonic measurements at the specified Point of Common Coupling (PCC). This study will provide the user with data on the actual power system waveforms. Upstream transformers maximum load current shall be the unity factor for all data supplied in percentages. Data shall include total harmonic voltage and current distortion as required by IEEE standard. Additionally, individual current harmonic data shall be included to the 13th harmonic. I. I/O Expansion Interface Card with the following features: 1. PI regulator for setpoint pressure control 2. Four Isolated 24 VDC programmable digital inputs 3. An additional analog input for speed feedback to PI regulator 4. One Frequency Input (0 to 200 Hz) for digital control of current limit 5. Four programmable Isolated Digital Outputs (24 VDC rated) 6. One Form A output relay rated at 250 VAC or 24 VDC 7. Two NO/NC programmable output relays rated at 250 VAC or 24 VDC Additional control digital and analog signals can be activated through the standard keypad for customized interface with specific Building Automation Systems. J. Johnson Controls Metasys(tm) option card allows direct connection from the VTAC 7 to the Johnson N2 bus architecture. All configuration and control functions can be accessed through this card. Allows direct communication between the VTAC 7 microprocessor and the host Johnson system. Fault diagnostics, start/stop, speed commands, and all drive feedback's shall be available over a single RS485 communication connection. Discrete signals such as ByPass Run or Interlock Open shall also be mapped through the drive terminal strip to the Metasys system. The card shall have the ability to be used in a "monitor only" mode where control shall be from a AHU or similar type controller directly wired to the drive. Reliance document VTAC-409 January 1998 Copyright 2002 Rockwell Automation For more information call

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02

More information

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC

More information

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING PART 1-GENERAL 1.01 DESCRIPTION A. This specification is to cover a complete Variable Frequency motor Drive (VFD) consisting of a pulse width modulated (PWM) inverter designed for use on a standard NEMA

More information

VARIABLE FREQUENCY DRIVES Revised 4/30/2015 23 81 07-1 Mechanical Systems

VARIABLE FREQUENCY DRIVES Revised 4/30/2015 23 81 07-1 Mechanical Systems SECTION 23 81 07 - VARIABLE FREQUENCY DRIVES PART 1 - GENERAL 1.1 SUMMARY A. This section includes all variable frequency drives. All standard and optional features shall be included within the VFD panel

More information

32VFD Variable Frequency Drives for Centrifugal Chillers

32VFD Variable Frequency Drives for Centrifugal Chillers 32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to

More information

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY PowerGate - Cost effective solutions for F 1 Horsepower Rating 001 1-40 HP (208V) 075 1-75 HP (480V) Input Voltage 2V 208-240V 4V 380-480V Disconnect

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

MC Series Drives. Flexible, simple, rugged, robust! Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.

MC Series Drives. Flexible, simple, rugged, robust! Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives. Drives Flexible, simple, rugged, robust! Our promise Commitment to Price Leadership Price leadership is serious business. It takes continuous life cycle management to make price leadership a sustainable

More information

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

GPD 506/P5 Start-up Procedure and Checklist

GPD 506/P5 Start-up Procedure and Checklist GPD 506/P5 Start-up Procedure and Checklist Preparation for GPD506/P5 Drive Start-Up...2 HVAC Start-Up Procedure for GPD 506/P5 WITH Bypass Option:...4 HVAC Start-Up Procedure for GPD 506/P5 WITHOUT Bypass

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930 Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930 Description Firetrol FTA1930 Digital Solid State Starting Fire Pump Controllers feature soft start, soft stop and

More information

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION Please read and understand the product instruction manual before installing, servicing or operating Yaskawa products. Technical content

More information

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications DC3 DC Drives Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications The Reliance Electric DC3 family of drives provides cost-effective variable speed control and operates

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

Z1000 HVAC Drive. 3 HP to 500 HP Fan and Pump Applications. Specifications

Z1000 HVAC Drive. 3 HP to 500 HP Fan and Pump Applications. Specifications Z1000 HVAC Drive 3 HP to 500 HP Fan and Pump Applications The Z1000 variable speed drive is designed for building automation applications such as fans, pumps, and cooling towers through 500 HP. The Z1000

More information

REGAL-BELOIT. Installation and Operation Manual. Variable Speed AC Motor Drives. Micro and PowerWash Series

REGAL-BELOIT. Installation and Operation Manual. Variable Speed AC Motor Drives. Micro and PowerWash Series REGAL-BELOIT Variable Speed AC Motor Drives Micro and PowerWash Series Installation and Operation Manual Manual Number: SB184 TABLE OF CONTENTS 1.0 GENERAL................................................1

More information

MC1000 Series Installation and Operation Manual

MC1000 Series Installation and Operation Manual MC1000 Series Installation and Operation Manual NOTE! The manual covers software version M108314 and above. Refer to parameter 63 for the software version of the drive you are working with. If you are

More information

Transfer Equipment Controls

Transfer Equipment Controls Control Types Manual Transfer Switches Nonautomatic Transfer Switches Automatic Transfer Switches The type of control system for the transfer switch will vary depending on the type of switching equipment

More information

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES 9900A The 9900A UPS system uses the most advanced IGBT in both the converter and inverter with Digital Signal Processor (DSP)

More information

City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION

City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION This Appendix A includes technical documents and specifications for the Toshiba 4200 FA 30 kva Uninterruptable Power

More information

Frequency Converter Fv

Frequency Converter Fv 2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)

More information

INSTRUCTION MANUAL PHOENIX DX 3 TO 3500 HP SENSORLESS VECTOR AC DRIVE

INSTRUCTION MANUAL PHOENIX DX 3 TO 3500 HP SENSORLESS VECTOR AC DRIVE INSTRUCTION MANUAL PHOENIX DX 3 TO 3500 HP SENSORLESS VECTOR AC DRIVE Thank You We at US Drives would like to say thank you for purchasing our product. We believe the Phoenix AC Drive Series is the most

More information

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters www.mbesi.com

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters www.mbesi.com 13 Aberdeen Way Elgin, SC 29045 Cell (803) 427-0791 VFD Fundamentals & Troubleshooting 19-Feb-2010 By: Timothy S. Irwin, P.E. Sr. Engineer tsi@mbesi.com Rotating Machinery Diagnostics & Instrumentation

More information

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3 FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3 Instruction Manual D2-3405-2 The information in this manual is subject to change without notice. Throughout this manual, the following

More information

EnVisioneering. www.danfossdrives.com

EnVisioneering. www.danfossdrives.com EnVisioneering As a world leader in components and solutions, Danfoss meets our customers challenges through EnVisioneering. This approach expresses our views on engineering innovation, energy efficiency,

More information

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

PowerFlex 700 and 700H Packaged Drives. Technical Data

PowerFlex 700 and 700H Packaged Drives. Technical Data PowerFlex 700 and 700H Packaged Drives Technical Data Overview The heart of every PowerFlex 700/700H packaged drive package is a PowerFlex Adjustable Frequency Drive. The packaged drives program provides

More information

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits: Variable Frequency Drives (or VFDs) are becoming almost standard part of aquatics equipment room packages. Most VFDs are fairly simple to install and operate however, they are quite complex with respect

More information

August 2004. www.danahermotion.com SECO DC DRIVES. Table of Contents

August 2004. www.danahermotion.com SECO DC DRIVES. Table of Contents SECO DC DRIVES SECO AC/DC DC Drives DRIVES Table of Contents August 2004 www.danahermotion.com Tel : 800 554 8466 Web site : www.danahermotion.com Mechanical and Electro-Mechanical Product Solutions by

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

VLT 6000 HVAC. Contents

VLT 6000 HVAC. Contents Contents Introduction Safety...3 Safety Guidelines...3 Warnings Against Unintended Start...3 Introduction...4 About this manual...4 Assumptions...4 References...4 Trademarks...5 Programming the VLT 6000

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the

More information

UFGS-16261 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS-16261 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 29 23 (April 2006) -------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-16261 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS MICRO SERIES INVERTERS MICRO SERIES INVERTER DRIVES Full feature, ultra-friendly operation. Programs and reads-out in plain English. Intelligent Power Module-IGBT s with a 16 bit Intel microprocessor.

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

Fundamentals of Inverter Fed Motors

Fundamentals of Inverter Fed Motors Fundamentals of Inverter Fed Motors Technical Manual 10/02 MN780 Contents Page The Growing Use Of Inverters.................................................................. 1 How Inverters Affect Motors....................................................................

More information

Variable Speed AC Motor Drives SM-Basic Installation and Operation Manual

Variable Speed AC Motor Drives SM-Basic Installation and Operation Manual ELECTRIC MOTORS, GEARMOTORS AND DRIVES Variable Speed AC Motor Drives SM-Basic Installation and Operation Manual We, EC Declaration of Conformity In accordance with EN45014:1998 Leeson Electric Corporation

More information

THERMAL MANAGEMENT SOLUTIONS

THERMAL MANAGEMENT SOLUTIONS t2000 Series Electronic heat-tracing controller Product Overview /COMMUNICATIONS INTERACE CARRIER REQ TO SEND The DigiTrace heat trace controller is designed to provide the benefits associated with single

More information

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of

More information

Parameter Settings for PowerFlex Drives Using Sine Wave Filters, dv/dt Filters, and Adjustable Voltage

Parameter Settings for PowerFlex Drives Using Sine Wave Filters, dv/dt Filters, and Adjustable Voltage Application Technique Parameter Settings for PowerFlex Drives Using Sine Wave Filters, dv/dt Filters, and Adjustable Voltage PowerFlex 750-Series, 700, and 700VC AC Drives Topic Page About This Document

More information

AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS Capacity Technology Inverter Technology Noise Level Operating Temperature Humidity Harmonic Distortion Total DC bus voltage Battery recharge time (After Complete discharge) to 100% charge Crest Factor

More information

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Introduction There is a growing trend in the UPS industry to create a highly efficient, more lightweight and smaller UPS

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch

More information

HVAC DRIVE H300 HVAC Drive for Building Automation

HVAC DRIVE H300 HVAC Drive for Building Automation HVAC DRIVE H300 HVAC Drive for Building Automation 1.0 hp - 450 hp (0.75 kw - 336 kw) 208 V - 230 V 400 V 575 V EMERSON Leading the world in climate technologies CONSIDER IT SOLVED. Emerson s promise to

More information

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600 Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600 Data Bulletin 0600DB1104 03/2012 Retain for future use. Electronic Trip Circuit Breaker Basics 0600DB1104 Table of Contents

More information

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification Assembly 025A0215 600A0942 Rev. A May 14, 2012 025A0215 Brushless DC Motor Controller Page 1 Revision History ECN # Date Rev Description

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

Line Reactors and AC Drives

Line Reactors and AC Drives Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences

More information

vacon x series rugged drives for the real world

vacon x series rugged drives for the real world vacon x series rugged drives for the real world 1 the toughest ac drives on the planet! The and X5 AC Drives are designed for REAL world that is not gentle or forgiving to electronic products. They have

More information

SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /

More information

How To Use The Vacon 0 Machinery

How To Use The Vacon 0 Machinery vacon 0 machinery how would you like your ac drive today? easy adaptation for customer requirements The Vacon 0 Machinery is an extremely compact AC drive for machine builders in the power range from 0.25

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation

More information

FREQUENCY CONTROLLED AC MOTOR DRIVE

FREQUENCY CONTROLLED AC MOTOR DRIVE FREQUENCY CONTROLLED AC MOTOR DRIVE 1.0 Features of Standard AC Motors The squirrel cage induction motor is the electrical motor motor type most widely used in industry. This leading position results mainly

More information

EFC 3600. Frequency converters

EFC 3600. Frequency converters 2 Bosch Rexroth AG Electric Drives and Controls Documentation Compact and complete: space saving side-by-side assembly, plug-in I/O terminals, with brake chopper and mains filter for ultra-simple installation

More information

Siemens Standard Drives. Application Handbook

Siemens Standard Drives. Application Handbook Siemens Standard Drives Application Handbook Martin Brown Siemens Standard Drives Congleton December 1997 1. Introduction....4 1.1 What is a Variable Speed Drive?...4 1.2 The Variable Frequency Inverter...7

More information

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications

More information

Principles of Adjustable Frequency Drives

Principles of Adjustable Frequency Drives What is an Adjustable Frequency Drive? An adjustable frequency drive is a system for controlling the speed of an AC motor by controlling the frequency of the power supplied to the motor. A basic adjustable

More information

A1000 Cheat Sheet (Open Loop Vector)

A1000 Cheat Sheet (Open Loop Vector) A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to

More information

GTEC transfer switch open transition

GTEC transfer switch open transition GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility

More information

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5 White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC

More information

TOSHIBA G9000 80/100/160/225 kva

TOSHIBA G9000 80/100/160/225 kva CORPORATE OFFICE 13131 WEST LITTLE YORK ROAD HOUSTON, TX 77041 PHONE: (713) 466-0277 (800) 231-1412 FACSIMILE: (713) 896-5226 TOSHIBA G9000 80/100/160/225 kva GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8

Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8 Door Mount UPS (Patent Pending) Shelf Mount UPS (Patent Pending) DESCRIPTION: The Always On NDM (door mount) and NSM (shelf mount) Series UPS s are dual conversion online UPS systems provided in slim,

More information

Power Quality. Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost

Power Quality. Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost Power Quality Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost A voltage sag is defined as a decrease in voltage magnitude below 90% of nominal, but not a complete interruption. The typical

More information

SPEEDMASTER MICRO SERIES COMPACT INVERTERS

SPEEDMASTER MICRO SERIES COMPACT INVERTERS SPEEDMASTER MICRO SERIES COMPACT INVERTERS Installation and Operation Manual EC Declaration of Conformity TABLE OF CONTENTS 1.0 GENERAL....................................................... 2 PRODUCT

More information

Commercial Refrigeration Temperature and Defrost Controls

Commercial Refrigeration Temperature and Defrost Controls Commercial Refrigeration Temperature and Defrost Controls UNI-LINE PRODUCT KNOWLEDGE 2010 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys

More information

Products and solutions for lifting systems

Products and solutions for lifting systems Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded

More information

SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion

More information

Variable Speed Drives

Variable Speed Drives Water Circulation Pumps & Circulators Variable Speed Drives The Advantage variable speed AC drives presents the most advanced and user-friendly solutions in the marketplace. Featuring optimal reactions

More information

Speed Control Relays SX2

Speed Control Relays SX2 SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................

More information

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog 2011. www.toshiba.com/ind

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog 2011. www.toshiba.com/ind www.toshiba.com/ind 2011 Toshiba International Corporation Rev. 110504 Industrial Catalog 2011 13131 W. Little York Road Houston, TX 77041 Tel: 713-466-0277 Fax: 713-466-8773 US: 800-231-1412 Canada: 800-872-2792

More information

TR1 Series VFD. Variable Frequency Drives TR1-SLB005-EN

TR1 Series VFD. Variable Frequency Drives TR1-SLB005-EN TR1 Series VFD Variable Frequency Drives October 2003 175R5568 Introduction Trane TR1 Series VFD The most commonly used motor in HVAC installations today is the three-phase, asynchronous AC induction motor,

More information

Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives

Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives User Manual Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives Catalog Number 20A-DG01 Topic Page General Description 2 What Is the DriveGuard Safe Torque Off

More information

Single Phase Soft Starter

Single Phase Soft Starter Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................

More information

Specification Requirements DBL 700MX and 1000MX Series UPS

Specification Requirements DBL 700MX and 1000MX Series UPS Specification Requirements DBL 700MX and 1000MX Series UPS Theory of Operation Upon loss of utility power, the UPS inverter shall continue to provide seamless pure sine-wave AC from the batteries without

More information

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE WHITE PAPER WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE EXPLANATION AND ASSISTANCE FOR APPLYING SOLID STATE SOFT STARTERS IN TRADITIONAL REDUCED VOLTAGE APPLICATIONS Introduction..............................................................2

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE SBP1930-61 FTA1930 Digital Solid State Starting Electric Fire Pump Controllers Product Description Fire Pump Controllers for Business-Critical Continuity

More information

Reliance Electric GV3000/SE Industrial AC Drive

Reliance Electric GV3000/SE Industrial AC Drive Reliance Electric GV3000/SE Industrial AC Drive Multi-Purpose variable speed control of 1-400 HP three-phase motors, with Volts/Hertz or Vector mode operation as standard FLEXIBLE Control Whether you need

More information

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify. SECTION 263354 STATIC UPS TESTING AND COMMISSIONING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes 1. System start-up services. 2. Battery charging. 3. Load bank testing. 4. Battery load testing. 5.

More information

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual Patented Ultra Fast CL Circuit Prevents Demagnetization in PM Motors Installation and Operating Instructions

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fire pumps

More information

Easy to connect - Easy to configure Easy to install

Easy to connect - Easy to configure Easy to install SIMPLE TO USE... CG Drive- SK is an easy drive - easy to connect, easy to configure and easy to install. Easy to connect - All connectors are generously sized and clearly labeled. Easy to configure - The

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information