TURNING AIR INTO SOLUTIONS. SQUARE INLINE CENTRIFUGAL FANS DSI BSI
|
|
- Lawrence Jenkins
- 7 years ago
- Views:
Transcription
1 TURNING AIR INTO SOLUTIONS. SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 March 06
2 SQUARE INLINE CENTRIFUGAL FANS Models DSI BSI Twin City Fan s DSI direct drive and type BSI belt driven square inline fans are specifically designed for duct applications handling relatively clean air, including supply, exhaust and return air systems. These fans offer high efficiency and quiet operation in a compact design that can be mounted in any position (horizontal, vertical or angular). Duct collars are provided for easy mounting without the need for square to round duct transitions. The units can be easily serviced through the side access panels without removing duct connections. DSI Direct Drive Square inline centrifugal units feature high efficient, nonoverloading, backward inclined centrifugal wheels precisely matched to a spun venturi. All wheels are statically and dynamically balanced. Units are manufactured under strict quality assurance standards to insure cataloged performance and years of maintenance-free operation. Square inline fans are not intended for outdoor applications. Variable Speed Control Variable speed control is available on direct drive DSI models. The speed control option allows adjustment of airflow for system balancing. Model DSI Sizes Available in 0 sizes from 080 through 6 Performance Airflow to,800 CFM Static pressure to " w.g. BSI Belt Driven All DSI and BSI models are UL/cUL 70 listed, for electrical, File No. E8680. Twin City Fan & Blower certifies that the Models DSI and BSI shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication and AMCA Publication and comply with the requirements of the AMCA Certified Ratings Program. Model BSI Sizes Available in 9 sizes from 080 through 40 Performance Airflow to 7,400 CFM Static pressure to." w.g. Fan Efficiency Grade (FEG) certification applies to Model DSI Sizes A, AE, 0A, 0AE, 0AN, 0ANE, 6A, 6AE, 6AN and 6ANE and Model BSI, Sizes 080A, 090A, 00A, 0A, 0A, A, A, 0A, 0A, 6A, 6A, 80A, 80A, 0A, 0A, A, A, 4A, 4A, 70A, 70A, 00A, 00A, 0A, 0A, 6A, 6A, 40A, 40A. FS0 For complete product performance, drawings, and available accessories, download Fan Selector at tcf.com. TWIN CITY FAN - CATALOG 40
3 CONSTRUCTION FEATURES Construction DSI BSI Housings - Housing assembly features heavy-gauge galvanized steel construction Removable Side Panels - Removable side panels provide easy access for service and maintenance without the need to remove duct connections. Complete removal of the power assembly is also possible through side access panels. Side panels can provide a 90-degree side discharge. Requires optional side discharge accessory. Duct Collars - Duct collars provide ready attachment to ductwork and eliminate the need for square to round duct transitions. Belt Tube/Bearing Cover - Constructed of heavy gauge galvanized steel, the belt tube and bearing cover enclose the belts, fan sheave and bearings within the airstream (Model BSI). Drive Frame - Motor and drive frame are constructed of heavy gauge galvanized steel. The pivoting motor base makes for simple belt tensioning (Model BSI). Wheel - Backward inclined non-overloading, all-aluminum wheel and hub statically and dynamically balanced to assure long life and quiet operation. Mounting Brackets - Galvanized steel mounting brackets for easy mounting in horizontal or vertical position. Pulleys - Heavy-duty cast iron adjustable pulleys to permit speed variation (Model BSI). Shaft - Precision ground and polished with a first critical speed of at least % of the fan s maximum operating speed (Model BSI). Bearings - All models are furnished with prelubricated cast iron pillow block bearings with zerk fittings, designed for an average life (L-0) of 00,000 hours or more at maximum cataloged operating speeds (Model BSI). Disconnect Switch - Mounted and prewired NEMA- disconnect switch provided as standard for servicing the unit without the danger of an accidental start.
4 OPTIONS/ACCESSORIES 4 6 Belt Guard is a formed galvanized steel guard NEMA R rain proof safety disconnect switch is available to cover the drive assembly on Model BSI. available for positive electrical shutoff of the fan and Belt guard is offered in lieu of motor cover. the protection of service personnel. 4 Motor Cover is a formed galvanized steel cover available on Model BSI to completely cover the motor and drives. Motor cover serves as OSHA belt guard. Extended Lube Lines Exterior mounting zerk fittings are available with lines to the fan shaft bearings (Model BSI) for relubrication from outside the unit. Vibration Isolators Spring or neoprene type vibration isolators are available for ceiling suspended or floor mounted installations. 6 Backdraft Dampers, with automatic or motorized operation, feature felt-edged damper blades for quiet operation. Damper frames are constructed of galvanized steel and blades are constructed of 6-gauge aluminum. All dampers ship loose for field mounting in ductwork. Motorized dampers are recommended for low CFM applications to assure unrestricted airflow. Motorized dampers are available with, 08, 0, 460, 7 or 4 volt service. End switches are available. See dimensional data for sizing. 4 TWIN CITY FAN - CATALOG 40
5 OPTIONS/ACCESSORIES Variable Speed Control Variable speed control is Outlet Guard Inlet and outlet guards are available an optional accessory on all DSI models, to allow the for all models. Guards mount inside the unit and do adjustment of airflow for system balancing. Variable not interfere with the attachment of ductwork. speed controllers are solid-state (Tri-ac) design and are designed to start the motor on high speed for better startup characteristics. Variable speed controls can be shipped separately, factory installed, or field installed on the unit at a later date. Motor must be ODP V, PSC or shaded pole type. Filter Box A filter box containing two inch aluminum wire mesh, removable and washable filters is available for attachment to the fan inlet side. The filter box is constructed of galvanized steel, with duct collars for easy mounting and removable side panels for easy filter cleaning or replacement. Disposable paper filters are also available. One inch filters are available on either type. For filter box pressure drops contact factory. See page 4 for dimensional data. Other Accessories Include: Special Coatings Insulated Housings Aluminum Construction Stainless Steel Hardware NEMA 4 & 7/9 Disconnect Switches
6 SQUARE INLINE CENTRIFUGAL FANS EC Motors Model DSI Overview Twin City Fan offers its own line of custom engineered Electronically Commutated (EC) motors. Electronic commutation is the latest motor technology to be used in direct drive fans. Also known in the industry as Brush Free or Brushless DC, the EC motors utilize an electronic circuitboard to control the functionality of the motor. The motor operates off of single phase AC power, which is converted to DC power within the motor s circuitry. The result is a highly efficient motor, even at part load, with an expanded speed control range and a variety of speed control options from which to choose. EC motors are available in ODP, TENV and TEFC enclosures. Motor Mounted Speed Control Dial DSI Direct Drive With EC Motor Remote Mounted Speed Control Dial Benefits Efficiencies up to 8% Constant efficiency as the motor speed is varied Up to 66% energy savings over traditional PSC motors Performance range comparable to a belt drive fan with reduced maintenance benefits of a direct drive fan 80% usable turndown range as compared with 40% maximum on PSC motors Soft start gives fans smooth, quiet start Lower operating temperatures result in longer life and reduces energy consumption Heavy-duty ball bearings are permanently lubricated Elimination of VFD results in lower initial cost Speed Control Options Motor Mounted Dial A potentiometer is mounted to the motor housing offering full speed control range. Speed adjustment is made with a small flat head screwdriver making system balance simple and easy.also eliminates the need to mount or wire a speed controller. 0-0V DC Lead A 6" long control lead is prewired to the motor which accepts a 0-0V DC signal and can be wired into building control systems. Remote Mounted Dial A wall mounted dial allows the fan to be controlled from within the building by sending the motor a 0-0V DC signal. This option includes a V to 4V AC transformer mounted in a NEMA electrical enclosure. 0-0V DC Lead For Building Control Systems ECTEFC Motors Available in & 6 TWIN CITY FAN - CATALOG 40
7 SIDE DISCHARGE OPTIONS Side discharge kits (including panels, mounting collars, and necessary hardware) are available to provide -way, -way, or -way discharges. This option provides exceptional adaptability for any installation, as well as avoiding the system effect of disrupted airflow when the ductwork has to take a 90-degree turn. Configurations RIGHT OPTION FIGURE CONFIGURATION Standard A Rear B Left -Way C Right D Left and Right -Way E Left and Rear F Right and Rear -Way G Left, Right and Rear NOTE: Performance will change depending on the position of the discharge. See correction factor table below. Percentages based on (inline) cataloged performance, but are not AMCA certified. Always check B when selecting motor and fan size. LEFT LEFT FIG. B INLET RIGHT INLET REAR LEFT FIG. C INLET INLET FIG. D FIG. E REAR REAR RIGHT REAR RIGHT INLET INLET LEFT INLET Fig. A FIG. F FIG. G Performance Correction Factors DISCHARGE 0.0" SP.00" SP.0" SP.00" SP AVG. CFM B CFM B CFM B CFM B CFM B -Way 0.7%.0% 4.0% 0.8%.8% 08.% 0.0% 0.%.% 08.7% -Way 4.7% 06.% 8.% 09.7% 0.%.4% 6.8% 4.0% 0.0% 0.7% -Way.% 0.9% 7.4% 09.7%.6%.0% 7.% 4.0% 9.8% 0.7% NOTE: The performance correction factors shown above are not licensed to bear the AMCA Certified Ratings Seal. Duct Openings LEFT AND RIGHT DISCHARGE REAR DISCHARGE/INLET MODEL MODEL DUCT COLLAR DUCT SIZE DUCT COLLAR DUCT SIZE BSI DSI WIDTH HEIGHT REQUIRED WIDTH HEIGHT REQUIRED x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x NOTE: Damper size should be /8" less than duct size required, or same size as duct collar. 7
8 PERFORMANCE DATA DSI 60 Hz EC MOTOR SIZE MTR 080AE /4 090AE /4 PSC MOTOR SIZE 080A MTR MAX. B / / / A 00AE / 00A 0AE /4 0A ANE /4 AN AE, A 0ANE, 0AN 0AE 6ANE 6AE / / / / / / / / / / / / / / * / / * 70. / / A /* 70.7 ** 6AN / / * 70.9 / A * CFM SONE Outlet Area:. ft Outlet Area:.90 ft Outlet Area:.90 ft Outlet Area: 4.8 ft Outlet Area: 4.8 ft * Designates motors that cannot be used with speed controller. ** Performance available with 60 ECODP motors or EC Motor is an Electronically Commutated Motor. 70 ECTEFC motors. 60 maximum. PSC Motor is a Permanent Split Capacitor Motor.. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Performance ratings do not include the effects of appurtenances (accessories).. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard Values shown are for Installation Type B: free inlet hemispherical sone levels. FAN EFF. GRADE N/A N/A N/A N/A N/A FEG6 FEG FEG6 FEG60 FEG60 8 TWIN CITY FAN - CATALOG 40
9 BSI 080A Outlet Area =.7 ft PERFORMANCE DATA Fan Efficiency Grade: FEG0 /4 / / / MAXIMUM MOTOR FRAME SIZE: 4T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation Type B: free inlet hemispherical sone levels. 9
10 PERFORMANCE DATA BSI 090A Outlet Area =.6 ft Fan Efficiency Grade: FEG / / / / MAXIMUM MOTOR FRAME SIZE: 4T BSI 00A Outlet Area =.0 ft / / / / MAXIMUM MOTOR FRAME SIZE: 4T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels. 0 TWIN CITY FAN - CATALOG 40
11 BSI 0A Outlet Area =.67 ft PERFORMANCE DATA / / / / / MAXIMUM MOTOR FRAME SIZE: 4T BSI 0A /4 / / /4 / Outlet Area =.67 ft Fan Efficiency Grade: FEG MAXIMUM MOTOR FRAME SIZE: 4T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels.
12 PERFORMANCE DATA BSI A /4 / / /4 / Outlet Area =. ft Fan Efficiency Grade: FEG MAXIMUM MOTOR FRAME SIZE: 4T BSI A /4 / / /4 / Outlet Area =. ft Fan Efficiency Grade: FEG MAXIMUM MOTOR FRAME SIZE: 4T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels. TWIN CITY FAN - CATALOG 40
13 BSI 0A /4 / / /4 / Outlet Area =.90 ft PERFORMANCE DATA Fan Efficiency Grade: FEG MAXIMUM MOTOR FRAME SIZE: 84T BSI 0A / / /4 / Outlet Area =.90 ft Fan Efficiency Grade: FEG MAXIMUM MOTOR FRAME SIZE: 84T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels.
14 PERFORMANCE DATA BSI 6A / / /4 / Outlet Area = 4.8 ft MAXIMUM MOTOR FRAME SIZE: 4T BSI 6A / /4 / Outlet Area = 4.8 ft MAXIMUM MOTOR FRAME SIZE: 4T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels. 4 TWIN CITY FAN - CATALOG 40
15 BSI 80A / / /4 / Outlet Area =.8 ft PERFORMANCE DATA MAXIMUM MOTOR FRAME SIZE: 84T BSI 80A / /4 / Outlet Area =.8 ft MAXIMUM MOTOR FRAME SIZE: 84T. Performance certified is for Installation Type AB Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels.
16 PERFORMANCE DATA BSI 0A / / /4 / Outlet Area = 7.8 ft MAXIMUM MOTOR FRAME SIZE: 84T BSI 0A / /4 / Outlet Area = 7.8 ft MAXIMUM MOTOR FRAME SIZE: 84T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels. 6 TWIN CITY FAN - CATALOG 40
17 BSI A / / /4 / Outlet Area = 8.0 ft PERFORMANCE DATA MAXIMUM MOTOR FRAME SIZE: T BSI A /4 / Outlet Area = 8.0 ft MAXIMUM MOTOR FRAME SIZE: T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels. 7
18 PERFORMANCE DATA BSI 4A / /4 / 7 / Outlet Area = 9.77 ft MAXIMUM MOTOR FRAME SIZE: T BSI 4A / 7 / Outlet Area = 9.77 ft MAXIMUM MOTOR FRAME SIZE: T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels. 8 TWIN CITY FAN - CATALOG 40
19 BSI 70A / /4 / 7 / Outlet Area =. ft PERFORMANCE DATA MAXIMUM MOTOR FRAME SIZE: T BSI 70A / 7 / Outlet Area =. ft Fan Efficiency Grade: FEG MAXIMUM MOTOR FRAME SIZE: T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels. 9
20 PERFORMANCE DATA BSI 00A / 7 / Outlet Area =.44 ft MAXIMUM MOTOR FRAME SIZE: T BSI 00A / 7 / Outlet Area =.44 ft Fan Efficiency Grade: FEG MAXIMUM MOTOR FRAME SIZE: T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels. 0 TWIN CITY FAN - CATALOG 40
21 BSI 0A / 7 / Outlet Area = 6.46 ft PERFORMANCE DATA MAXIMUM MOTOR FRAME SIZE: 6T BSI 0A / 7 / Outlet Area = 6.46 ft Fan Efficiency Grade: FEG MAXIMUM MOTOR FRAME SIZE: 6T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels.
22 PERFORMANCE DATA BSI 6A / 7 / Outlet Area = 7.6 ft Fan Efficiency Grade: FEG MAXIMUM MOTOR FRAME SIZE: 6T BSI 6A / 7 / Outlet Area = 7.6 ft MAXIMUM MOTOR FRAME SIZE: 6T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels. TWIN CITY FAN - CATALOG 40
23 BSI 40A / 7 / Outlet Area =.0 ft PERFORMANCE DATA Fan Efficiency Grade: FEG MAXIMUM MOTOR FRAME SIZE: 6T BSI 40A / 7 / 0 Outlet Area =.0 ft MAXIMUM MOTOR FRAME SIZE: 6T. Performance certified is for Installation Type B: Free inlet, ducted outlet.. Power rating (B) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at.m ( ft.) in a hemispherical free field calculated per AMCA International Standard 0.. Values shown are for installation type B: free inlet hemispherical sone levels.
24 DIMENSIONAL DATA DISCONNECT SWITCH E 0.6 Model DSI, Direct Drive F H G AIRFLOW A D C SQ. DUCT COLLAR B SQ. MODEL DSI EC MOTOR SIZES A B C D E F G H DAMPER SIZE Notes:. All figures are in inches unless noted otherwise.. Average ship weight is for fan and motor assembly.. Dimensions are not to be used for construction. AVG. SHIP WT. (LBS.) SIDE DISCHARGE SIZE 080A 080AE x x A 090AE x x.88 00A 00AE x x.88 0A 0AE x x.88 A/AN AE/ANE x x A/0AN 0AE/ANE x x A/6AN 6AE/ANE x x.88 D-40J Filter Box Assembly SIZE A SQ. B C D E F FILTER FILTER AVG. SHIP SIZE QTY. WT. (LBS.) 080/ x6x x6x 0/ x6x 48 / x0x 8 0/ x0x 00 6/ x0x 0 80/ x0x 0 0/ x6x 4 90 / x6x / x0x x6x 49 70/ x0x / x0x / x6x 84 6/ x0x 80 40/ x0x x6x 6 0 FAN ASSEMBLY REF ONLY (BSI SHOWN) FILTER BOX D-40- B A SQ. C SQ. DUCT ADAPTER AIRFLOW Notes:. All figures are in inches unless noted otherwise.. Filter box option is shipped separately for field installation.. For filter box information, see page. D E F 4 TWIN CITY FAN - CATALOG 40
25 Model BSI, Belt Driven DIMENSIONAL DATA OPTIONAL MOTOR COVER E OPTIONAL BELT GUARD F H J MAX G AIRFLOW A D C SQ. DUCT COLLAR B SQ. MODEL BSI A B C D E F G H J DAMPER SIZE AVG. SHIP WT. (LBS.) SIDE DISCHARGE SIZE 080A x x A x x.88 00A x x.88 0A/0A x x.88 A/A x x A/0A x x A/6A x x.88 80A/80A x x.88 0A/0A x x 7.88 A/A x x A/4A x x.88 70A/70A x x.88 00A/00A x x A/0A x x A/6A x x A/40A x x D-40J Notes:. All figures are in inches unless noted otherwise.. Average ship weight is for fan and motor assembly.. Dimensions are not to be used for construction.
26 TYPICAL SPECIFICATIONS Model DSI Supply or exhaust fans shall be of the direct drive model DSI centrifugal square inline type, as manufactured by Twin City Fan, Minneapolis, Minnesota. PERFORMANCE Performance ratings shall conform to AMCA Standard 0 (fan efficiency grade), (air performance) and (sound performance). Fans shall be tested in accordance with ANSI/AMCA Standard 0 (air performance) and 00 (sound performance) in an AMCA accredited laboratory. Fans shall be licensed to bear the AMCA certified ratings seal for both sound and air, and fan efficiency grade (FEG). Model DSI shall be UL 70 listed. CONSTRUCTION Unit exterior shall be constructed of heavy gauge galvanized steel. The fan housing shall be square in shape and readily attachable to building ductwork. Unit side panels shall be removable for easy access for maintenance and service. The power assembly shall be removable as a complete module through the side access panel. Fan housings shall have universal mounting brackets to accommodate horizontal or vertical installations. Fans shall bear a permanently attached nameplate displaying model and serial number of the unit for future identification. WHEEL Fan wheels shall be of the non-overloading centrifugal backward inclined type, constructed of aluminum and containing a matching inlet venturi for optimum unit performance. Wheels shall be statically and dynamically balanced. MOTOR Motors shall be of the heavy-duty ball bearing type, closely matched to the fan load. A disconnect switch shall be factory installed and wired to the fan motor as standard. All motors shall be UL recognized. ACCESSORIES When specified, accessories such as backdraft damper, belt guard, motor cover, insulated housing, vibration isolators, side discharge, remote lubrication lines, inlet and outlet guards, special coatings, and filter box option shall be provided by Twin City Fan to maintain one source responsibility. FACTORY RUN TEST All fans prior to shipment shall be completely assembled and test run as a unit at operating speed or maximum allowed for the particular construction type. Each wheel shall be statically and dynamically balanced in accordance with ANSI/AMCA "Balance Quality and Vibration Levels for Fans" to Fan Application Category BV-, Balance Quality Grade G6.. Balance readings shall be taken by electronic type equipment in the axial, vertical, and horizontal directions. Records shall be maintained and a written copy shall be available upon request. GUARANTEE The manufacturer shall guarantee the workmanship and materials for its DSI Square Inline Fans for at least one () year from startup or eighteen (8) months from ship date, whichever occurs first. 6 TWIN CITY FAN - CATALOG 40
SECTION 23 34 13. A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.
PART 1 GENERAL SECTION 23 34 13 HVAC FANS 1.01 SUMMARY A. Section Includes: 1. Exhaust fans. 2. Transfer fans. B. Related Documents: 1. Drawings and general provisions of the Contract, including General
More informationRecirculating Roof Fans Models ESRMD, ESRMDF and ERD
Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Four-Way Fan Exhaust Supply Mix Recirculate BUILDING VALUE IN AIR. October 2005 Recirculating Roof Fans Exhaust/Supply/Recirculation/Mix Model ESRMD
More informationUPBLAST & HOODED PROPELLER ROOF VENTILATORS
The Industrial Choice. Model D53 / B53 Model HD53 / HB53 UPBLAST & HOODED ELLER ROOF VENTILATORS Direct Drive & Belt Driven Model D53 / B53 Upblast Exhaust Fans Model HD53 / HB53 Hooded Supply & Exhaust
More informationVentilation Solutions Kitchens. fantech
Ventilation Solutions Kitchens 2 Kitchens Today s kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationINSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional
More informationCommercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
More informationCE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationSECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
More informationTube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller
Tube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller Belt Drive Low and High Pressure October 009 Features Page Header Tube Axial Roof Upblast Fans Greenheck belt drive tube axial upblast
More informationSECTION 233000 HVAC AIR DISTRIBUTION
1320 / Talent Community Center 233000-1 HVAC AIR DISTRIBUTION SECTION 233000 HVAC AIR DISTRIBUTION PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Ductwork. 2. Ductwork accessories. 3. Fans. 4. Air
More informationUNIVERSITY OF ROCHESTER DESIGN STANDARDS OCTOBER 18, 2013
SECTION 233416 - CENTRIFUGAL HVAC FANS PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. Fans shall be dynamically balanced and factory-tested and certified in accordance with applicable AMCA test codes. All
More informationAMD-33 Air Measuring Station with VCD-33 Control Damper
Application and esign Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized
More informationGas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
More informationModel 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com
Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022
More informationM7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
More informationVXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
More informationFIRE DAMPER APPLICATION GUIDE
FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire
More informationAMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.
Application and esign Thermal ispersion Air Measuring Station with VC-23 Control amper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationElement D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
More informationLow Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
More informationCooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
More informationMotor Accessories. C-Face Kits for Field Conversion NEMA AC Motors
C-Face Kits for Field Conversion NEMA AC s Features: Complete kits with all hardware necessary for converting Baldor 56 though 449T frame ridgid base motors to C-Face mounting with base. For Baldor conversion,
More informationROOF TOP MOUNTED Air Handler Specification
ROOF TOP MOUNTED Air Handler Specification PART 1: GENERAL (Model RT) Mechanical Specification 1.01 WORK INCLUDED A. Provide complete air handling unit(s) suitable for outdoor installation. Contractor
More informationproduct application guide
Understanding Fan System Effects Fan Application FA/101-99 product application guide A technical bulletin for engineers, contractors and students in the air movement and control industry. The air moving
More informationAIR CONDITIONING PRODUCTS COMPANY
Quality Products Fixed Louvers AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter
More informationCATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB
SPECIFICATIONS CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB Page 1 Powerful VERTEX TM Complete Capture Design rivals the finest island hoods. Compact design allows the choice of many cooktop
More informationHorizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
More informationDirect Gas Fired [Make-Up Air / Displacement Ventilation / Space Heating] System
Section 15622 AA-Series (rev. 04/16/15) Direct Gas Fired [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets
More informationCFM @.0 SP H/M/L AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3 1/8 1468/1209/1063 60 7562/6050/4840 34/31/28 115
Air Circulators High Velocity Floor Fans Circulate Large Volumes of Air Product Specifications Size Spd HP HZ CFM/WATT @.0 SP AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3
More informationD Youville College July 31, 2008 New Academic Building Cannon Design Project No. 002935.00
SECTION 22 6119 - COMPRESSED-AIR EQUIPMENT FOR LABORATORY AND HEALTHCARE PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged, oilless scroll air compressors. 1.2 DEFINITIONS A. Actual Air: Air
More informationJohnson Air-Rotation Systems
AR Series TM Johnson Air-Rotation Systems Solution TM D Series TM FF Series TM 80/20 PR Series TM Johnson Air-Rotation systems announces a major addition to its product line, completing its line of high
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationSECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
More informationEnergy Saving ECM Motors and Fans. 2010 Ventilation Catalogue
Energy Saving ECM s and Fans 2010 Ventilation Catalogue CONTENTS For ellington, sustainability is about delivering products at competitive prices while preserving the environment for future generations.
More informationEVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce
More informationSINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
More informationBC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
More informationFans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011
Fans and Air Handling Units Will Rea and Paul Pilutti February 16 th, 2011 HTS Lunch and Learns Available Online Visit www.htseng.com Engineering Tools Resource Center Contents Fans Fan Curves Fan Laws
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationOWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING
OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING PLEASE READ AND SAVE THESE INSTRUCTIONS - 2 - INTRODUCTION TO THE BIG
More information300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
More informationCentrifugal Fans and Pumps are sized to meet the maximum
Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed
More informationSpecifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
More informationSECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
More informationInstallation Manual CLIFC Fan & Coil Variable Speed
Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation
More informationEDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction
Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to
More informationTECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationInstallation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
More informationWe will discuss common industrial applications with guides for the proper use of electric motors on these.
INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationPerformance Rating of Room Fan- Coils
ANSI/AHRI Standard 440 with Addendum 1 (Formerly ARI Standard 440) 2008 Standard for Performance Rating of Room Fan- Coils ANSI/AHRI STANDARD 440-2008 WITH ADDENDUM 1, PERFORMANCE RATING OF ROOM FAN-COILS
More informationPLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB
OVERVIEW TYPE: GGB All composite construction Rigid extruded upvc aerofoil blade section Integral blade seals for low leakage operation Individual blades driven via reinforced styrene gear wheels in maintenance
More informationPump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationOperation and Installation Manual. Max Series
Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat
More informationSECTION 15732 AIR CONDITIONING UNIT
SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration
More informationsecurity products metric sizes Redefine your comfort zone. www.titus-hvac.com
metric sizes secure lethal objects monitoring areas suicide deterrent Redefine your comfort zone. www.titus-hvac.com humid areas prevents corrosion minimum security medium security maximum security Table
More informationFresh Air Enclosure Cooling Filter Fans
763.576.3200 SPEC-00306 K763.422.2211 COOLING FRESH AIR ENCLOSURE COOLING FILTER FANS Fresh Air Enclosure Cooling Filter Fans TFP SIDE-MOUNT TFP10 215 CFM (365 m3/hr.) TFP6 140 CFM (238 m3/hr.) TFP4 55
More informationOwner s Manual EFX. Explosion-Proof Exhaust Fan. This manual covers installations, maintenance, repair and replacement parts. WARNING!
Heaters for the Harshest Environments Owner s Manual ISO 9001 EFX Explosion-Proof Exhaust Fan This manual covers installations, maintenance, repair and replacement parts. WARNING! READ ALL IMPORTANT NOTICES
More informationSPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION 238221 - BLOWER COIL UNITS
ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION
More informationExplosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
More informationMTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More informationUniversity of Houston Master Construction Specifications Insert Project Name
SECTION 23 62 13 - AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",
More informationTesting Capabilities. Worldwide Designers & Manufacturers of Air Moving Equipment
Testing Capabilities Twin Twin City City Fan Fan Companies, Companies, Ltd. Ltd. Worldwide Designers & Manufacturers of Air Moving Equipment TestingCapabilities Twin City Fan Companies, Ltd. In today s
More informationUM Series UniModule. Pre-assembled, C-face Clutches and Brakes. Original Design Sizes 210 & 215. GEN 2 Design Sizes 50, 100 & 180
re-assembled, C-face Clutches and Brakes UniModules offer the ultimate in Clutch/ Brake performance and convenience. UniModules offer the same performance as EM s without the assembly required. Completely
More informationPOWERS Controls No. 4 Pneumatic Damper Actuator
POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check
More informationNational System of Garage Ventilation s Engineering Guide
National System of Garage Ventilation s Engineering Guide In designing a fume removal system, it is extremely important to determine the following: 1. Type of apparatus to be exhausted (i.e. gasoline,
More informationSingle Package Vertical Air Conditioners. Vert-I-Pak
Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better
More informationOPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
More informationProduct Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
More informationVertical Break Parallel (VBP) / Vertical Break Slant (VBS)
August, 2009 Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) Type VBPA (Aluminum) / Type VBPC (Copper) Type VBSA (Aluminum) / Type VBSC (Copper) PASCOR Air Break Switch Technology PASCOR offers
More informationSPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling.
SPACE COOLERS P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com The leader in packaged Space Cooling. 2 Table of Contents Description Space Cooler from Coil Company. A
More informationA. Section includes air conditioning units, controls and control panels.
SECTION 23 81 23 - COMPUTER-ROOM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes air conditioning units, controls and control panels. 1.2 REFERENCES A. Air-Conditioning, Heating, and
More informationDigi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
More informationTechnical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
More informationPIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
More informationDirect Gas-Fired Indoor and Outdoor Heating and Make-Up Air Units
Direct Gas-Fired Indoor and Outdoor Heating and Make-Up Air Units horizontal configuration vertical configuration 7-150.3 MAY, 2015 Table of Contents Direct-fired make-up units are designed to provide
More informationHVAC Control & Balancing Dampers Models VCD, MBD and RBD
HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* August 1 2013 HVAC Control and Balancing Dampers Commercial Control Dampers are used in buildings to regulate
More informationA. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
More informationTransformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
More informationScraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
More informationFAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com
FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case,
More informationMedical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
More informationCURTAIN TYPE FIRE DAMPERS
URTAIN TYPE FIRE urtain Fire Damper Basics Definition of a Fire Damper: The National Fire Protection Association (NFPA) Standard 9A defines a fire damper as "a device, installed in an air distribution
More informationMAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
More informationICQ Series - square centrifugal
product ICQ Square Centrifugal (TEFC) dimensions mm 280-710 poles & duty 4-8 / up to 4,500 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ
More informationMechanical Rooftop Custom Capabilities
Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition
More informationRadiant Temperature Sensor TY7321
AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationLow Cost. Lower Energy Costs. Higher Efficiency.
HI-E DRY dehumidifiers remove two to three times more water per kilowatt hour of electricity than conventional dehumidifiers. Low Cost. Lower Energy Costs. Higher Efficiency. Therma-Stor designed an efficient,
More informationCORROSION RESISTANT FRP FANS & BLOWERS
CORPORATION CORROSION RESISTANT FRP FANS & BLOWERS Superior Quality High Efficiency Low Noise Level Competitive Pricing Fans in Stock Dedicated to detail, precision and quality control Welcome to M.K.
More informationElegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
More informationUHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual
UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationLSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS
FOR COOLERS ABOVE +34ºF Low silhouette, draw through, high velocity units Capacity from 4,500 to 39,000 BTU/HR./10ºF TD LSA LSE, LSR & LST FOR COOLERS AND FREEZERS FROM -20ºF TO +34ºF Low silhouette, draw
More information