1 CAT.ES0-6 Direct Operated Port Solenoid Valve For Air, Water, Oil, Steam Reduced power consumption ( specification). W. 8 W W 0. W.. W 6 W New VX Series VX/ /

2 Reduced power consumption Improved corrosion resistance ( specification) VX: 6 W. W VX: 8 W W VX:. W W Special magnetic material adopted Enclosure: Equivalent to IP6 Flame resistance UL9V-0 conformed Flame resistant mold coil material Low-noise construction Improved maintenance performance Special construction enables to reduce the metal noise. ( specification) Maintenance is performed easily due to the threaded assembly. Direct Operated Port Solenoid Valve For Air, Water, Oil, Steam Ne Series VX/ / New Normally Closed (N.C.) / Normally Open (N.O.) / Common (COM.) Material Orifice diameter ø.mm ø.mm ømm ømm VX VX VX /8, / /, /8 /, /8 ody Guide pin C Stainless steel PPS Stainless steel Seal Main valve poppet Fixed sealant NR EPDM F NR EPDM PTFE Fluid Air, Water, Oil, Steam Manifold: Normally Closed (N.C.) / Normally Open (N.O.) / Common (COM.) VVX VVX VVX Orifice diameter ø.mm ø.mm ømm ømm Features (Common SUP/EXH type) IN port OUT port EXH port / /8, / / ody C Material Guide pin Seal PPS Stainless steel NR EPDM Fluid Air, Oil

3 Pilot Operated Port for Zero Differential Pressure Direct Operated Port Pilot Operated Port NewVX// NewVXD// NewVXZ/ For Air, Vacuum, Water, Steam, Oil For Air, Water, Oil For Air, Vacuum, Water, Oil Valve type Orifice dia. mmø Valve type Orifice dia. mmø Valve type Orifice dia. mmø N.C./N.O. /8 to / to 0 N.C./N.O. / to A to 0A 0 to 0 N.C./N.O. / to 0 to Pilot Operated Port Water Hammer Relief, Pilot Operated Port Pilot Operated Port for High Pressure VXP// VXR// VXH For Steam (Air, Water, Oil) For Water, Oil For Air, Water, Oil Valve type Orifice dia. mmø Valve type Orifice dia. mmø Valve type Orifice dia. mmø N.C./N.O. / to A to 0A 0 to 0 N.C./N.O. / to 0 to 0 N.C. / to / 0 Port for Dust Collector (Solenoid type, Air Operated type) Air Operated / Port VXF/, VXFA/ VXA/, VXA/ For Air For Air, Vacuum, Water, Oil The VX series has been renewed as the new VX series, with a new construction. Valve type Orifice dia. mmø N.C. / to / 0 to 0 Valve Port Orifice dia. type size mmø VXA/ N.C./N.O. /8 to / to 0 VXA/ COM. /8 to /8. to Features

4

5 Solenoid Coil Electrical Entry Grommet Conduit DIN terminal Conduit terminal Single Unit Coil: Class, Class H Rated Voltage 00 VAC, 00 VAC, 0 VAC, 0 VAC, 0 VAC, 0 VAC, 8 VAC, V, V Material ody C, Seal NR,, EPDM, PTFE, F Direct Operated Port Solenoid Valve Series VX// For Air, Water, Oil, Steam Valve Normally Closed (N.C.) / Normally closed (N.C.) Normally Open (N.O.) / Normally open (N.O.) Common (COM.) Common (COM.) Orifice dia.. mmø. mmø mmø mmø VX /8 / VX / /8 VX / /8 For Vacuum Pad For Steam For Oil For Water For Air Specifications Manifold Construction Valve Normally closed (N.C.) Normally open (N.O.) Common (COM.) ase Common SUP/EXH type Solenoid Coil Coil: Class, Class H Rated Voltage 00 VAC, 00 VAC, 0 VAC, 0 VAC, 0 VAC, 0 VAC, 8 VAC, V, V Material ody C ase Aluminum Seal NR,, EPDM Electrical Entry Grommet Conduit DIN terminal Conduit terminal Orifice dia. Normally Closed (N.C.) / Normally Open (N.O.) / Common (COM.). mmø. mmø mmø mmø (Common SUP/EXH type) IN port OUT port EXH port VX VX / /8, / / VX Dimensions

6 Common Specifications Standard Specifications Valve specifications Coil specifications Valve construction Withstand pressure (MPa) ody material Seal material Enclosure Environment Rated voltage AC (Class coil, uilt-in full-wave rectifier type) AC (Class H coil) Allowable voltage fluctuation AC (Class coil, Allowable uilt-in full-wave rectifier type) leakage voltage AC (Class H coil) Coil insulation type Electrical entry, Grommet with surge voltage (GS) has a rating of IP0. Direct operated poppet.0 C, NR,, EPDM, PTFE, F Dusttight, Low jetproof (equivalent to IP6)* Location without corrosive or explosive gases 00 VAC, 00 VAC, 0 VAC, 0 VAC, 0 VAC, 0 VAC, 8 VAC V, V ±0% of rated voltage % or less of rated voltage 0% or less of rated voltage % or less of rated voltage Class, Class H Solenoid Coil Specifications Specification VX VX VX Power consumption (W). Temperature rise (C) Note) 60 Note) The values are for an ambient temperature of 0ºC and at the rated voltage. AC Specification (Class coil, uilt-in full-wave rectifier type) Apparent power (VA) Temperature rise (C) Note) VX VX VX There is no difference in the frequency and the inrush and energized apparent power, since a rectifying circuit is used in the AC (Class ). Note) The values are for an ambient temperature of 0ºC and at the rated voltage. AC Specification (Class H coil) Apparent power (VA) Frequency (Hz) Inrush Energized Temperature rise (C) Note) VX VX VX Note) The values are for an ambient temperature of 0ºC and at the rated voltage.

7 All Options (Single Unit) 0 Applicable Fluid Check List VX Fluid and application Air Medium vacuum, Non-leak, Oil-free Water Heated water Oil Note ) Steam (Max.8ºC) Copper-free, Fluoro-free Note ) Others Option symbol Seal material Main valve poppet Fixed sealant Option symbol G M Note, ) V Note, ) G E P A H D N S Q P C K Note, ) If using for other fluids, please consult with SMC. All Options (Manifold) NR NR EPDM F EPDM EPDM F NR NR EPDM PTFE EPDM EPDM PTFE VX 00 Fluid and application Air Medium vacuum, Non-leak, Oil-free Oil Note ) Others ody material/ Shading coil material Note 6) C C C C/Cu /Ag C C/Cu /Ag C/Cu /Ag /Ag C Guide pin material PPS PPS PPS PPS PPS PPS Coil insulation type Note ) Option symbol Option Seal material ody material/ Guide pin Coil insulation symbol Main valve poppet Fixed sealant Shading coil material Note 6) material type Note ) NR NR C PPS V Note, ) C PPS A D E EPDM Aluminum is only available with the material for a manifold base. If using for other fluids, please consult with SMC. EPDM C C/Cu C C/Cu Note ) The leakage amount (0 6 Pa m /s) of V, M options are values when differential pressure is 0. MPa. Note ) V, M and K options are for oil-free treatment. Note ) The dynamic viscosity of the fluid must not exceed 0 mm /s or less. Note ) Coil insulation type Class H: AC spec. only, Class /AC spec.: built-in full-wave rectifier type only Note ) The nuts (non-welded parts) are nickel plated on the C material. Note 6) There is no shading coil attached to spec. or Class /AC spec. PPS PPS H H H H H H Note COM. only COM. only COM. only, Oil-free Dimensions Construction For Vacuum Pad For Steam For Oil For Water For Air Specifications

8 Series VX// For Air /Single Unit (Inert gas, Non-leak, Medium vacuum) / Valve Specifications N.C. N.O. COM. Passage symbol Passage symbol Passage symbol /8 (6A) / (8A) /8 (0A) Orifice diameter Max. operating pressure differential (MPa) (mmø) N.O. COM VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 N.C Note) Weight of grommet type. Add 0 g for conduit, 0 g for DIN terminal, and 60 g for conduit terminal type respectively. Also, add 60 g for VX, 80 g for VX and VX respectively for bracket option. Refer to Glossary on page, for details on the max. operating pressure differential and the max. system pressure C[dm /(s bar)] Flow characteristics b Cv Max. system pressure (MPa).0 Note) Weight (g) Fluid and Ambient Temperature Power source AC Fluid temperature (ºC) Solenoid valve option (symbol), G V, M 0 Note) to 60 0 Note) to 0 0 Note) to 60 0 Note) to 0 Note) Dew point temperature: 0ºC or less Ambient temperature (ºC) 0 to 60 0 to 0 Valve Leakage Internal Leakage / External Leakage Max. operating Leakage rate Seal material pressure differential Air NR, From 0 to less than MPa cm /min or less MPa or more cm /min or less Non-leak, Medium vacuum Note) 0 6 Pa m /sec or less Note) The leakage amount (0 6 Pa m /sec) for the V and M option are values when the differential pressure is 0. MPa.

9 Direct Operated Port Solenoid Valve Series VX// For Air / Single Unit Refer to Table () shown Valve / ody type 0 Z N.C. / Single unit N.O. / Single unit COM. / Single unit Thread type T F N Rc NPTF G NPT How to Order (Single Unit) VX 0 VX 0 AC/Class coil (uilt-in full-wave rectifier type) Suffix Oil-free spec. 00 VAC 0/60 Hz 00 VAC 0/60 Hz 0 VAC 0/60 Hz 0 VAC 0/60 Hz V 6 8 Refer to Table () shown Orifice diameter Refer to Table () shown Refer to page for ordering coil only. Solenoid valve option Refer to Table () shown Rated voltage V 0 VAC 0/60 Hz 8 VAC 0/60 Hz 0 VAC 0/60 Hz Table () Orifice Diameter Port Size Solenoid valve model VX VX VX 0 (/8) Port 0 (/) symbol () 0 (/) 0 (/8) 0 (/) 0 (/8) Table () Solenoid Valve Option Seal material ody material/ Option Main valve Fixed Shading coil symbol poppet sealant material G M V NR NR C Stainless steel Stainless steel C (. mmø) Guide pin material PPS Refer to Table () shown Orifice symbol (diameter) (. mmø) ( mmø) Coil insulation type Note Note) ( mmø) Non-leak (0 6 Pa m /sec), Medium vacuum (0. Pa.abs), Oil-free Note) The leakage amount (0 6 Pa m /sec) for the V and M option are values when the differential pressure is 0. MPa. Electrical entry (AC/) G -Grommet GS-With grommet surge voltage T -With conduit terminal TS -With conduit terminal and surge voltage TL -With conduit terminal and light TZ -With conduit terminal, surge voltage and light G G R C -Conduit racket None With bracket racket is neither mountable nor removable. uilt-in full-wave rectifier type D -DIN terminal Connector DS -DIN terminal with surge voltage DL -DIN terminal with light DZ -DIN terminal with surge voltage and light DO -For DIN terminal (without connector, gasket is included.) DIN type is available with class only. Refer to Table () for available combinations between each electrical option (S, L, Z) and rated voltage. Surge voltage is integrated into the AC/Class coil, as a standard. Table () Rated Voltage Electrical Option Class Rated voltage S L Z With surge With light and AC/ Voltage With Voltage voltage surge voltage symbol light AC V 00 V 0 V 0 V 0 V 8 V 0 V V V Note) Note) Note ) Option S, Z are not available as surge voltage is integrated into the AC/Class coil, as a standard. Class H coil is not available. For Air Specifications For Water For Oil For Steam For Vacuum Pad Construction Dimensions

10 Series VVX// For Air /Manifold (Inert gas, Non-leak, Medium vacuum) Solenoid Valve for Manifold / Valve Specifications N.C. N.O. COM. Passage symbol Passage symbol Passage symbol Orifice diameter (mmø).. VX-00 VX-00 VX-00 VX-00 VX-00 VX-00 VX-00 VX-00 VX-00 Max. operating pressure differential (MPa) N.C N.O COM C[dm /(s bar)] Refer to Glossary on page for details on the max. operating pressure differential and the max. system pressure..6 Flow characteristics b Cv Max. system pressure (MPa).0 Fluid and Ambient Temperature Power source AC Fluid temperature (ºC) Solenoid valve option (symbol) V 0 Note) to 60 0 Note) to 0 0 Note) to 60 0 Note) to 0 Note) Dew point temperature: 0ºC or less Ambient temperature (ºC) 0 to 60 0 to 0 Valve Leakage Internal Leakage / External Leakage Leakage rate Seal material NR, Max. operating pressure differential From 0 to less than MPa cm /min or less MPa or more cm /min or less Note) The leakage amount (0 6 Pa m /sec) for the V option are values when the differential pressure is 0. MPa. Air Non-leak, Medium vacuum Note) 0 6 Pa m /sec or less 6

11 Direct Operated Port Solenoid Valve Series VVX// For Air / Manifold AC/Class coil (uilt-in full-wave rectifier type) Refer to Table () shown Valve / ody type N.C. / Manifold N.O. / Manifold COM. / Manifold How to Order Manifold ases VVX VVX VVX Manifold base lanking plate part no. For VX: VVX-A- For VX/: VVX-A- How to Order Manifold Assemblies (Example) Enter the valve and blanking plate to be mounted under the manifold base part number. How to Order (Solenoid Valve for Manifold) Seal material F 0 (Individual port) Rc /8 Rc / Common port sizes are all Rc /. Indicating numbers shown below are for common ports. Type SUP port EXH port N.C. N.O. Example VVX-0-00 VAC 0/60 Hz 00 VAC 0/60 Hz 0 VAC 0/60 Hz 0 VAC 0/60 Hz V VX 00 G VX 00 G R Orifice diameter Refer to Table () shown NR Solenoid valve option Refer to Table () shown 6 8 Refer to Table () shown... set VX-00-GR... sets VVX-A... set D side Station Refer to page for ordering coil only. n Rated voltage V 0 VAC 0/60 Hz 8 VAC 0/60 Hz 0 VAC 0/60 Hz Number of manifolds 0 stations 0 0 stations Suffix Z Oil-free spec. is the symbol for mounting. Add an in front of the part numbers for solenoid valves, etc. to be mounted. U side Enter the product s part number in order, counting the st station from the left in the m a n i f o l d arrangement, when viewing the individual port in front. The common port on the Suffix Z Oil-free spec. G -Grommet GS-With grommet surge voltage T -With conduit terminal TS -With conduit terminal and surge voltage TL -With conduit terminal and light TZ -With conduit terminal, surge voltage and light Table () Orifice Diameter Solenoid valve model VX VX VX Table () Solenoid Valve Option Option symbol Seal material ody material Guide pin material V (. mmø) Main valve poppet NR Fixed sealant NR Orifice symbol (diameter) (. mmø) C uilt-in full-wave rectifier type Electrical entry (AC/) C -Conduit D -DIN terminal DS -DIN terminal with surge voltage DL -DIN terminal with light DZ -DIN terminal with surge voltage and light DO -For DIN terminal (without connector, gasket is included.) DIN type is available with class only. Refer to Table () for available combinations between each electrical option (S, L, Z) and rated voltage. Surge voltage is integrated into the AC/Class coil, as a standard. ( mmø) PPS ( mmø) Coil insulation type Note Note) Non-leak (0 6 Pa m / sec), Medium vacuum (0. Pa.abs), Oil-free Aluminum is only available as a material for the manifold base. Note) The leakage amount (0 6 Pa m /sec) for the V option are values when the differential pressure is 0. MPa. Table () Rated Voltage Electrical Option Class Rated voltage S L Z With surge With light and AC/ Voltage With Voltage voltage surge voltage symbol light AC V 00 V 0 V 0 V 0 V 8 V 0 V V V Note) Note) Class H coil is not available. Note) Option S, Z are not available as surge voltage is integrated into the AC/Class coil, as a standard. For Air Specifications For Water For Oil For Steam For Vacuum Pad Construction Dimensions

12 Series VX// For Water /Single Unit / Valve Specifications N.C. N.O. COM. Passage symbol Passage symbol Passage symbol /8 (6A) / (8A) /8 (0A) Orifice Max. operating pressure differential (MPa) diameter (mmø) N.O. COM VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 N.C Note) Weight of grommet type. Add 0 g for conduit, 0 g for DIN terminal, and 60 g for conduit terminal type respectively. Also, add 60 g for VX, 80 g for VX and VX respectively for bracket option. Refer to Glossary on page for details on the max. operating pressure differential and the max. system pressure Flow characteristics Av x 0-6 m Cv converted Max. system pressure (MPa).0 Note) Weight (g) Fluid and Ambient Temperature Valve Leakage Power source AC Note) With no freezing Fluid temperature (ºC) Solenoid valve option (symbol), G, H E, P to 60 to 99 to 0 Ambient temperature (ºC) 0 to 60 0 to 0 Internal Leakage / External Leakage Seal material Max. operating pressure differential NR,, EPDM From 0 to less than MPa MPa or more Leakage rate (Water) 0. cm /min or less 0. cm /min or less 8

13 Direct Operated Port Solenoid Valve Series VX// For Water / Single Unit, AC/Class H coil AC/Class coil (uilt-in full-wave rectifier type) Refer to Table () shown Valve / ody type 0 N.C. / Single unit N.O. / Single unit COM. / Single unit Z Suffix Oil-free spec. VX VX Orifice diameter Refer to Table () shown How to Order (Single Unit) Solenoid valve option Refer to Table () shown Refer to Table () shown Thread type T F N Rc NPTF G NPT 0 G 0 G R G -Grommet GS-With grommet surge voltage C -Conduit racket None With bracket racket is neither mountable nor removable. uilt-in full-wave rectifier type Electrical entry For Air Specifications For Water For Oil 00 VAC 0/60 Hz 00 VAC 0/60 Hz 0 VAC 0/60 Hz 0 VAC 0/60 Hz V 6 8 Refer to Table () shown Refer to page for ordering coil only. Rated voltage V 0 VAC 0/60 Hz 8 VAC 0/60 Hz 0 VAC 0/60 Hz T -With conduit terminal TS -With conduit terminal and surge voltage TL -With conduit terminal and light TZ -With conduit terminal, surge voltage and light D -DIN terminal Connector DS -DIN terminal with surge voltage DL -DIN terminal with light DZ -DIN terminal with surge voltage and light DO -For DIN terminal (without connector, gasket is included.) DIN type is available with class only. Refer to Table () for available combinations between each electrical option (S, L, Z) and rated voltage. Surge voltage is integrated into the AC/Class coil, as a standard. For Steam For Vacuum Pad Table () Orifice Diameter Port Size Solenoid valve model Orifice symbol (diameter) VX VX VX (. mmø) (. mmø) ( mmø) ( mmø) 0 (/8) Port 0 (/) symbol () Table () Solenoid Valve Option Seal material ody material/ Option Main valve Fixed Shading coil symbol poppet sealant material G E P H NR EPDM 0 (/) 0 (/8) NR EPDM 0 (/) 0 (/8) C C/Cu /Ag Guide pin material PPS Stainless steel PPS Coil insulation type H Note Heated water Table () Rated Voltage Electrical Option Class Rated voltage S L Z With surge With light and AC/ Voltage With Voltage voltage surge voltage symbol light AC AC/ AC 8 6 Rated voltage Voltage symbol V 00 V 0 V 0 V 0 V 8 V 0 V V V Voltage 00 V 00 V 0 V 0 V 0 V 8 V 0 V V V Note) S With surge voltage Class H L With light Note) Note) Option S, Z are not available as surge voltage is integrated into the AC/Class coil, as a standard. Z With light and surge voltage specification is not available. 9 Construction Dimensions

14 Series VX// For Oil /Single Unit / Valve Specifications N.C. N.O. COM. Passage symbol Passage symbol Passage symbol /8 (6A) / (8A) /8 (0A) Orifice Max. operating pressure differential (MPa) diameter (mmø) N.O. COM VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 N.C Note) Weight of grommet type. Add 0 g for conduit, 0 g for DIN terminal, and 60 g for conduit terminal type respectively. Also, add 60 g for VX, 80 g for VX and VX respectively for bracket option. Refer to Glossary on page for details on the max. operating pressure differential and the max. system pressure Flow characteristics Av x 0-6 m Cv converted Max. system pressure (MPa).0 Note) Weight (g) Fluid and Ambient Temperature Valve Leakage Power source AC Fluid temperature (ºC) Solenoid valve option (symbol) A, H D, N Note) to 60 Note) to 0 Note) to 0 Note) Dynamic viscosity: 0 mm /s or less Ambient temperature (ºC) 0 to 60 0 to 0 Internal Leakage / External Leakage Seal material Max. operating pressure differential From 0 to less than MPa MPa or more Leakage rate (Oil) 0. cm /min or less 0. cm /min or less 0

15 Direct Operated Port Solenoid Valve Series VX// For Oil / Single Unit How to Order (Single Unit), AC/Class H coil AC/Class coil (uilt-in full-wave rectifier type) Refer to Table () shown Valve / ody type 0 N.C. / Single unit N.O. / Single unit COM. / Single unit Z Suffix Oil-free spec. VX VX Orifice diameter Refer to Table () shown Solenoid valve option Refer to Table () shown Refer to Table () shown Thread type T F N Rc NPTF G NPT A A 0 G 0 G R G -Grommet GS-With grommet surge voltage C -Conduit racket None With bracket racket is neither mountable nor removable. uilt-in full-wave rectifier type Electrical entry For Air Specifications For Water For Oil 00 VAC 0/60 Hz 00 VAC 0/60 Hz 0 VAC 0/60 Hz 0 VAC 0/60 Hz V 6 8 Refer to Table () shown Refer to page for ordering coil only. Rated voltage V 0 VAC 0/60 Hz 8 VAC 0/60 Hz 0 VAC 0/60 Hz T -With conduit terminal TS -With conduit terminal and surge voltage TL -With conduit terminal and light TZ -With conduit terminal, surge voltage and light D -DIN terminal Connector DS -DIN terminal with surge voltage DL -DIN terminal with light DZ -DIN terminal with surge voltage and light DO -For DIN terminal (without connector, gasket is included.) DIN type is available with class only. Refer to Table () for available combinations between each electrical option (S, L, Z) and rated voltage. Surge voltage is integrated into the AC/Class coil, as a standard. For Steam For Vacuum Pad Table () Orifice Diameter Port Size Solenoid valve model Orifice symbol (diameter) VX VX VX (. mmø) (. mmø) ( mmø) ( mmø) 0 (/8) Port 0 (/) symbol () Table () Solenoid Valve Option Seal material Option Main valve Fixed symbol poppet sealant A H D N 0 (/) 0 (/8) 0 (/) 0 (/8) ody material/ Shading coil material C C/Cu /Ag Guide pin material PPS Stainless steel The additives contained in oil are different depending on the type and manufacturers, so the durability of the seal materials will vary. For details, please consult with SMC. Coil insulation type H Table () Rated Voltage Electrical Option Class Rated voltage S L Z With surge With light and AC/ Voltage With Voltage voltage surge voltage symbol light AC AC/ AC 8 6 Rated voltage Voltage symbol V 00 V 0 V 0 V 0 V 8 V 0 V V V Voltage 00 V 00 V 0 V 0 V 0 V 8 V 0 V V V Note) S With surge voltage Class H L With light Note) Note) Option S, Z are not available as surge voltage is integrated into the AC/Class coil, as a standard. Z With light and surge voltage specification is not available. Construction Dimensions

16 Series VVX// For Oil /Manifold Solenoid Valve for Manifold / Valve Specifications N.C. N.O. COM. Passage symbol Passage symbol Passage symbol Orifice diameter (mmø).. VX-00 VX-00 VX-00 VX-00 VX-00 VX-00 VX-00 VX-00 VX-00 Max. operating pressure differential (MPa) N.C N.O COM Refer to Glossary on page for details on the max. operating pressure differential and the max. system pressure. Av x 0-6 m Cv converted Flow characteristics 0 Max. system pressure (MPa).0 Fluid and Ambient Temperature Valve Leakage Power source AC Fluid temperature (ºC) Solenoid valve option (symbol) A D Note) to 60 Note) to 0 Note) to 0 Note) Dynamic viscosity: 0 mm /s or less Ambient temperature (ºC) 0 to 60 0 to 0 Internal Leakage / External Leakage Seal material Max. operating pressure differential From 0 to less than MPa MPa or more Leakage rate (Oil) 0. cm /min or less 0. cm /min or less

17 Direct Operated Port Solenoid Valve Series VVX// For Oil / Manifold How to Order (Solenoid Valve for Manifold), AC/Class H coil AC/Class coil (uilt-in full-wave rectifier type) Refer to Table () shown Valve / ody type Z How to Order Manifold ases VVX VVX VVX Manifold base N.C. / Manifold N.O. / Manifold COM. / Manifold Suffix Oil-free spec. lanking plate part no. For VX: VVX-A-F For VX/: VVX-A-F (Individual port) Rc /8 Rc / Common port sizes are all Rc /. Indicating numbers shown below are for common ports. Type SUP port EXH port N.C. N.O. Seal material: How to Order Manifold Assemblies (Example) Enter the valve and blanking plate to be mounted under the manifold base part number. Example VVX set VXA-00-GR.. sets VVX-A-F... set D side Station VX A 00 G VX A 00 G R Orifice diameter Refer to Table () shown 0 Suffix Z Oil-free spec. n Solenoid valve option Refer to Table () shown 00 VAC 0/60 Hz 00 VAC 0/60 Hz 0 VAC 0/60 Hz 0 VAC 0/60 Hz V 6 8 Refer to Table () shown Refer to page for ordering coil only. Number of manifolds 0 stations 0 0 stations is the symbol for mounting. Add an in front of the part numbers for solenoid valves, etc. to be mounted. U side Enter the product s part number in order, counting the st station from the left in the manifold arrangement, when viewing the individual port in front. The common port on the right side is plugged. Rated voltage V 0 VAC 0/60 Hz 8 VAC 0/60 Hz 0 VAC 0/60 Hz Table () Orifice Diameter Solenoid valve model VX VX VX A D uilt-in full-wave rectifier type Electrical entry C -Conduit G -Grommet GS-With grommet surge voltage T -With conduit terminal TS -With conduit terminal and surge voltage TL -With conduit terminal and light TZ -With conduit terminal, surge voltage and light DIN type is available with class only. Refer to Table () for available combinations between each electrical option (S, L, Z) and rated voltage. Surge voltage is integrated into the AC/Class coil, as a standard. (. mmø) Orifice symbol (diameter) (. mmø) ( mmø) Table () Solenoid Valve Option Seal material Option Main valve Fixed symbol poppet sealant ody material/ Shading coil material C C/Cu D -DIN terminal DS -DIN terminal with surge voltage DL -DIN terminal with light DZ -DIN terminal with surge voltage and light DO -For DIN terminal (without connector, gasket is included.) ( mmø) Guide pin material PPS Stainless steel Coil insulation type Aluminum is only available as a material for the manifold base. The additives contained in oil are different depending on the type and manufacturers, so the durability of the seal materials will vary. For details, please consult with SMC. Table () Rated Voltage Electrical Entry Electrical Option Rated voltage Class Class H S L Z S L Z AC/ Voltage With surge With With light and With surge With With light and Voltage voltage surge voltage voltage surge voltage symbol light light AC 8 00 V 00 V 0 V 0 V 0 V 8 V 0 V Note) Note) V specification is not 6 V available. Note) Option S, Z are not available as surge voltage is integrated into the AC/Class coil, as a standard. H Dimensions Construction For Vacuum Pad For Steam For Oil For Water For Air Specifications

18 Series VX// For Steam /Single Unit / Valve Specifications COM. Passage symbol /8 (6A) / (8A) /8 (0A) Orifice diameter (mmø)..... VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 VX-0 Max. operating pressure differential (MPa) COM Flow characteristics Av x 0-6 m Cv converted Note) Weight of grommet type. Add 0 g for conduit, 0 g for DIN terminal, and 60 g for conduit terminal type respectively. Also, add 60 g for VX, 80 g for VX and VX respectively for bracket option. Refer to Glossary on page for details on the max. operating pressure differential and the max. system pressure Max. system pressure (MPa).0 Note) Weight (g) Fluid and Ambient Temperature Valve Leakage Power source AC Fluid temperature (ºC) Solenoid valve option (symbol) S, Q 8 Ambient temperature (ºC) 0 to 60 Internal Leakage Seal material F External Leakage Seal material PTFE Leakage rate (Air) 0 cm /min or less Leakage rate (Air) cm /min or less

19 Direct Operated Port Solenoid Valve Series VX// For Steam / Single Unit How to Order (Single Unit) Refer to Table () shown Z Suffix Oil-free spec. Orifice diameter Refer to Table () shown 00 VAC 0/60 Hz 00 VAC 0/60 Hz 0 VAC 0/60 Hz 0 VAC 0/60 Hz Thread type T F N 8 Refer to Table () shown Valve / ody type COM. / Single unit Rc NPTF G NPT Refer to page for ordering coil only. VX S 0 Solenoid valve option Refer to Table () shown Refer to Table () shown Rated voltage 0 VAC 0/60 Hz 8 VAC 0/60 Hz 0 VAC 0/60 Hz G -Grommet GS-With grommet surge voltage T -With conduit terminal TS -With conduit terminal and surge voltage TL -With conduit terminal and light TZ -With conduit terminal, surge voltage and light G C -Conduit racket None With bracket racket is neither mountable nor removable. Electrical entry Refer to Table () for available combinations between each electrical option (S, L, Z) and rated voltage. For Vacuum Pad For Steam For Oil For Water For Air Specifications Table () Orifice Diameter Port Size Solenoid valve model Orifice symbol (diameter) VX VX VX (. mmø) (. mmø) ( mmø) ( mmø) 0 (/8) Port 0 (/) symbol () Table () Solenoid Valve Option Seal material ody material/ Option Main valve Fixed Shading coil symbol poppet sealant material S F Q Solenoid coil: AC/Class H only 0 (/) 0 (/8) PTFE 0 (/) 0 (/8) C/Cu /Ag Guide pin material Stainless steel Coil insulation type H Table () Rated Voltage Electrical Option Class H Rated voltage L AC/ AC Voltage symbol 8 6 Voltage 00 V 00 V 0 V 0 V 0 V 8 V 0 V V V S With surge voltage With light Z With light and surge voltage specification is not available. Construction Dimensions

20 For Vacuum Pad / Single Unit Series VXV// Vacuum circuit side is suited for a large orifice. Supply pressure side is suited for high pressure and a vacuum pad. Construction and dimensions are the same as the VX series. / Valve Specifications N.C. N.O. Passage symbol (example) Passage symbol (example) Orifice diameter (mmø) Port side Port side /8 (6A) / (8A) /8 (0A) VXV0-0 VXV-0 VXV0-0 VXV-0 VXV0-0 VXV0-0 VXV-0 VXV-0 VXV0-0 VXV0-0 VXV-0 VXV-0 Operating pressure (MPa) Port side Port side Low vacuum 0 to Low vacuum 0 to Low vacuum 0 to 0 to 0.9 Low vacuum 0 to 0 to to Low vacuum 0 to Low vacuum 0 to 0 to 0.9 Low vacuum 0 to 0 to 0.9 Low vacuum Flow characteristics Passage: Passage: C[dm / C[dm (s bar)] b Cv / (s bar)] b Cv Note) Weight of grommet type. Add 0 g for conduit, 0 g for DIN terminal, and 60 g for conduit terminal type respectively. Also, add 60 g for VX, 80 g for VX and VX respectively for bracket option. Refer to Glossary on page, for details on the max. operating pressure differential and the max. system pressure. Low vacuum: Up to. x 0 Pa Max. system pressure (MPa).0 Note) Weight (g) Fluid and Ambient Temperature Power source AC Fluid temperature (ºC) 0 Note) to 60 0 Note) to 60 Note ) Dew point temperature: 0C or less Ambient temperature (ºC) 0 to 60 0 to 0 Valve Leakage Internal Leakage / External Leakage Seal material NR, Note) Value when air pressure is applied. Leakage rate Note) Air cm /min or less 6

21 Direct Operated Port Solenoid Valve Series VX// For Vacuum Pad / Single Unit Valve / ody type 0 N.C. / Single unit N.O. / Single unit Z Suffix Oil-free spec. 00 VAC 0/60 Hz 00 VAC 0/60 Hz 0 VAC 0/60 Hz 0 VAC 0/60 Hz V Thread type T F N 6 8 Refer to Table () shown 0 (/8) Port 0 (/) symbol () Rc NPTF G NPT Refer to page for ordering coil only. 0 (/) 0 (/8) 0 (/) 0 (/8) How to Order (Single Unit) Solenoid valve option Refer to Table () shown Rated voltage V 0 VAC 0/60 Hz 8 VAC 0/60 Hz 0 VAC 0/60 Hz Table () Orifice Diameter Port Size Solenoid valve model Orifice symbol (diameter) Note) VXV VXV VXV (./ mmø) (./ mmø) Note) The orifice diameter shown above are for the supply pressure side/ vacuum side port. Table () Solenoid Valve Option Seal material Option ody material symbol A G H AC/Class coil (uilt-in full-wave rectifier type) Refer to Table () shown Main valve poppet NR NR Fixed sealant NR NR VXV VXV Orifice diameter Refer to Table () shown C 0 0 G 0 0 G R Refer to Table () shown Guide pin material PPS Coil insulation type Electrical entry (AC/) G -Grommet GS-With grommet surge voltage T -With conduit terminal TS -With conduit terminal and surge voltage TL -With conduit terminal and light TZ -With conduit terminal, surge voltage and light C -Conduit racket None With bracket racket is neither mountable nor removable. D -DIN terminal Connector DS -DIN terminal with surge voltage DL -DIN terminal with light DZ -DIN terminal with surge voltage and light DO -For DIN terminal (without connector, gasket is included.) DIN type is available with class only. Refer to Table () for available combinations between each electrical option (S, L, Z) and rated voltage. Surge voltage is integrated into the AC/Class coil, as a standard. Table () Rated Voltage Electrical Option Class Rated voltage S L AC/ AC Voltage symbol 8 6 Voltage 00 V 00 V 0 V 0 V 0 V 8 V 0 V V V With surge voltage Note) With light Z With light and surge voltage Note) Note) Option S, Z are not available as surge voltage is integrated into the AC/Class coil, as a standard. Class H coil is not available. uilt-in full-wave rectifier type For Air Specifications For Water For Oil For Steam For Vacuum Pad Construction Dimensions

22 For Vacuum Pad / Manifold Series VVXV// Construction and dimensions are the same as those of the VVX series. / Valve Specifications N.C. N.O. Passage symbol (example) Passage symbol (example) Orifice diameter (mmø) Port side Port side.... VXV-00 VXV-00 VXV-00 VXV-00 VXV-00 VXV-00 Operating pressure (MPa) Port side Low vacuum 0 to Low vacuum 0 to 0 to 0.9 Port side 0 to Low vacuum 0 to 0 to 0.9 Low vacuum C[dm / (s bar)] Flow characteristics Passage: Passage: b Cv C[dm / (s bar)] b Refer to Glossary on page for details on the max. operating pressure differential and the max. system pressure. Low vacuum: Up to. x 0 Pa Cv Max. system pressure (MPa).0 Fluid and Ambient Temperature Power source Fluid temperature (ºC) AC 0 Note) to 60 0 Note) to 60 Note ) Dew point temperature: 0C or less Ambient temperature (ºC) 0 to 60 0 to 0 Valve Leakage Internal Leakage / External Leakage Seal material NR, Note) Value when air pressure is applied. Leakage rate Note) Air cm /min or less 8

23 Direct Operated Port Solenoid Valve Series VVXV// For Vacuum Pad / Manifold Valve / ody type AC/Class coil (uilt-in full-wave rectifier type) Refer to Table () shown N.C. / Manifold N.O. / Manifold How to Order Manifold ases VVX VVX VVX 0 (Individual port) Rc /8 Rc / Common port sizes are all Rc /. Indicating numbers shown below are for common ports. Type N.C. N.O. 00 VAC 0/60 Hz 00 VAC 0/60 Hz 0 VAC 0/60 Hz 0 VAC 0/60 Hz V Vacuum side port Manifold base lanking plate part no. For VXV: VVX-A- For VXV/: VVX-A- How to Order Manifold Assemblies (Example) Enter the valve and blanking plate to be mounted under the manifold base part number. How to Order (Solenoid Valve for Manifold) VXV 00 G VXV 00 G R Orifice diameter Refer to Table () shown Solenoid valve option Refer to Table () shown SUP side port Seal material F 6 8 Refer to Table () shown Example VVX set VXV-00-GR.. sets VVX-A... set D side Station Refer to page for ordering coil only. NR n Rated voltage V 0 VAC 0/60 Hz 8 VAC 0/60 Hz 0 VAC 0/60 Hz Number of manifolds 0 stations 0 0 stations Suffix Z Oil-free spec. is the symbol for mounting. Add an in front of the part numbers for solenoid valves, etc. to be mounted. U side Enter the product s part number in order, counting the st station from the left in the manifold arrangement, when viewing the individual port in front. The common port on the right side is plugged. Table () Orifice Diameter Solenoid Orifice symbol (diameter) Note) valve model (./ mmø) (./ mmø) VXV VXV VXV Note) The orifice diameter shows the supply pressure side/vacuum side. Table () Solenoid Valve Option Seal material Option symbol Main valve Fixed poppet sealant ody material NR NR A C Aluminum is only available as a material for the manifold base. Table () Rated Voltage Electrical Option Class Rated voltage S L Z With surge With surge AC/ Voltage With Voltage voltage voltage symbol light AC Suffix Z Oil-free spec. G -Grommet GS-With grommet surge voltage T -With conduit terminal TS -With conduit terminal and surge voltage TL -With conduit terminal and light TZ -With conduit terminal, surge voltage and light V 00 V 0 V 0 V 0 V 8 V 0 V V V Note) uilt-in full-wave rectifier type Electrical entry (AC/) C -Conduit D -DIN terminal DS -DIN terminal with surge voltage DL -DIN terminal with light DZ -DIN terminal with surge voltage and light DO -For DIN terminal (without connector, gasket is included.) DIN type is available with class only. Refer to Table () for available combinations between each electrical option (S, L, Z) and rated voltage. Surge voltage is integrated into the AC/Class coil, as a standard. Note) Guide pin material PPS Coil insulation type Class H coil is not available. Note) Option S, Z are not available as surge voltage is integrated into the AC/Class coil, as a standard. 9 For Air Specifications For Water For Oil For Steam For Vacuum Pad Construction Dimensions

24 Series VX// For Air, Water, Oil, Steam Construction Single unit ody material C, Manifold ase material: Aluminum Manifold body material: C Port (N.C. EXH) (N.O. IN) i w y e t u r q t r q i w y e u! Port (N.C. IN) (N.O. EXH)! Port (N.C. OUT) (N.O. OUT) Port (N.C. (N.O. IN) EXH) o!0 o!!!!!0 Port (N.C. OUT) (N.O. OUT) Port (N.C. EXH) (N.O. IN) Component Parts No. Description ody Tube assembly Note) Armature assembly Return spring Nut 6 Solenoid coil O-ring 8 Clip Guide pin 9 assembly 0 Support spring O-ring Plate Standard C, Cu, C6, PTFE (NR) C Class molded (NR) PPS, C6 (NR) (NR) Material SK Option, Ag, PTFE (, EPDM, F) C/Ni plated Class H molded (, EPDM, PTFE) (, EPDM, F) (, EPDM, PTFE) The materials in parentheses are the seal materials. Note) Cu and Ag are not applicable to the spec and to the AC spec with built-in full-wave rectifier. Component Parts No. Description Manifold body Tube assembly Note) Armature assembly Return spring Nut 6 Solenoid coil O-ring 8 Clip Guide pin 9 assembly 0 Support spring O-ring Plate Gasket ase Standard, C6, PTFE (NR) Material, PTFE (, EPDM, F) C C/Ni plated Class molded Class H molded (NR) (, EPDM) SK PPS, C6 (NR) (, EPDM) (NR) (, EPDM) (NR) C, Cu Aluminum Option (, EPDM) The materials in parentheses are the seal materials. Note) Cu is not applicable to the spec and to the AC spec with built-in full-wave rectifier 0

25 Direct Operated Port Solenoid Valve Series VX// For Air, Water, Oil, Steam / Single Unit Dimensions: Single Unit / ody Material: C, Stainless Steel Normally closed (N.C.): VX0/VX0/VX0 Normally open (N.O.) : VX/VX/VX Common (COM.) : VX/VX/VX Grommet: G K D 00 F Width across flats H C Conduit: C Width across flats H D G/ K 80 F C For Air Specifications E x P A E x P A For Water K E Width across flats H A C Width across flats H E D Q DIN terminal: D Cable ø6 to ø G/ D M x P F Conduit terminal: T N K M x P A F C For Oil For Steam For Vacuum Pad With bracket G/ Construction T Dimensions x ø. Mounting hole R S N.C., N.O., COM. VX VX VX VX Orifice diameter ø., ø., ø ø., ø., ø ø., ø, ø ø., ø, ø P /8 / /, /8 /, /8 (mm) Electrical entry (AC/Class ) Grommet Conduit DIN terminal Conduit terminal K K K M K M N N.C., N.O., COM. VX VX VX VX Orifice diameter ø., ø., ø ø., ø., ø ø., ø, ø ø., ø, ø P /8 / /, /8 /, /8 A 6 8 C D 0 0 E 9 F 9.. H 6 (mm) Electrical entry (, AC/Class H) racket mounting Grommet Conduit DIN terminal Conduit terminal K K K M K M N Q R S T

26 Series VVX// For Air, Oil / Manifold Dimensions Manifold / ase Material Aluminum Normally closed (N.C.) Normally open (N.O.) Common (COM.) VVX/VVX/VVX W N Y Q x øe Mounting hole A X V x øe Mounting hole L L L L R S T H F D side Stations n U side G/ U M Port indication x Rc/ A C D L K L VVX VVX VVX Dimension L L L L n (stations) (mm) VVX VVX VVX A 0 0 C D E F H 6 K L M 9 N 9.. Q Grommet R 9... (mm) Electrical entry (, AC/Class H) Conduit DIN terminal Conduit terminal T T U V W X Y S 0 6 VVX VVX VVX Grommet R 0 6 (mm) Electrical entry (AC/Class ) Conduit DIN terminal Conduit terminal T T U V W X Y S 8..

27 Direct Operated Port Solenoid Valve Series VX// For Air, Water, Oil, Steam Replacement Parts Solenoid coil assembly part no. VX0 Series VX VX VX N G Rated voltage Note) 6 G -Grommet GS-With grommet surge voltage V V T -With conduit terminal TS -With conduit terminal and surge voltage TL -With conduit terminal and light TZ -With conduit terminal, surge voltage and light C -Conduit Electrical entry D -DIN terminal DS -DIN terminal with surge voltage Connector DL -DIN terminal with light DZ -DIN terminal with surge voltage and light DO -For DIN terminal (without connector) Refer to Table () for available combinations between each electrical option and rated voltage. AC/Class H coil VX0 8 Note ) Refer to Table () for available combinations. N G Series VX VX VX Rated voltage Note) 00 VAC 0/60 Hz 00 VAC 0/60 Hz 0 VAC 0/60 Hz 0 VAC 0/60 Hz 0 VAC 0/60 Hz 8 VAC 0/60 Hz 0 VAC 0/60 Hz Note ) Refer to Table () for available combinations. G -Grommet GS-With grommet surge voltage H C -Conduit Z Electrical entry AC/Class coil (uilt-in full-wave rectifier type) VX0 Series VX VX VX G -Grommet T -With conduit terminal TL -With conduit terminal and light N G R Rated voltage Note) 00 VAC 0/60 Hz 00 VAC 0/60 Hz 0 VAC 0/60 Hz 0 VAC 0/60 Hz 0 VAC 0/60 Hz 8 8 VAC 0/60 Hz 0 VAC 0/60 Hz Note ) Refer to Table () for available combinations. C -Conduit Electrical entry D -DIN terminal Connector DL -DIN terminal with light DO -For DIN terminal (without connector) Refer to Table () for available combinations between each electrical option and rated voltage. Surge voltage is integrated into the AC/Class coil, as a standard. Table () Rated Voltage Electrical Option Class Rated voltage L AC/ AC Voltage symbol 8 6 Voltage 00 V 00 V 0 V 0 V 0 V 8 V 0 V V V S With surge voltage Note) With light Z With light and surge voltage Note) Class H L specification is not available. Note) Option S, Z are not available since a surge voltage is integrated into the AC/Class coil, as a standard. When changing coils, AC/ are not interchangeable with each other, and Class and H coils are also not interchangeable with each other. S With surge voltage With light Z With light and surge voltage Dimensions Construction For Vacuum Pad For Steam For Oil For Water For Air Specifications T -With conduit terminal TS -With conduit terminal and surge voltage TL -With conduit terminal and light TZ -With conduit terminal, surge voltage and light Refer to Table () for available combinations between each electrical option and rated voltage.

28 Series VX// For Air, Water, Oil, Steam Replacement Parts Name plate part no. AZ-T-VX Clip part no. Valve model Enter by referring to How to Order For VX VX0N-0 For VX: VX0N-0 For VX: VX0N-0 Clip Name plate Solenoid coil DIN connector part no. Without electrical option With electrical option GDMA GDMA S L Z Electrical option With surge voltage With light With light and surge voltage Refer to Table () for available combinations between each electrical option (S, L, Z) and rated voltage. 6 Rated voltage 00 VAC, 0 VAC 00 VAC, 0 VAC, 0 VAC, 0 VAC V V 8 VAC Gasket part no. for DIN connector VCW0--9-

29 Solenoid Valve Flow Characteristics (How to indicate flow characteristics). Indication of flow characteristics Indication of the flow characteristics in specifications for equipment such as solenoid valve, etc. is depending on Table (). Table () Indication of Flow Characteristics Corresponding equipment Equipment for pneumatics Equipment for controlling process fluids Indication by international standard C, b Av Other indications S Cv Cv Standards conforming to ISO 68: 989 IS 890: 000 IS 890: 000 Equipment: IS 8, 8, 8, 89, 88 ANSI/(NFPA)T..: 990 IEC60--: 99 IS 00: 99 Equipment: IS 8, 8, 8. Equipment for pneumatics. Indication according to the international standards () Standards conforming to ISO 68: 989 : Pneumatic fluid powercomponents using compressible fluids Determination of flow-rate characteristics IS 890: 000 : Pneumatic fluid powercomponents using compressible fluids How to test flow-rate characteristics () Definition of flow characteristics Flow rate characteristics are indicated as a result of a comparison between sonic conductance C and critical pressure ratio b. Sonic conductance C : Values which divide the passing mass flow rate of an equipment in a choked flow condition by the product of the upstream absolute pressure and the density in the standard condition. Critical pressure ratio b : It is the pressure ratio which will turn to the choke flow (downstream pressure/upstream pressure) when it is smaller than this values. (critical pressure ratio) Choked flow : It is the flow in which the upstream pressure is higher than the downstream pressure and where sonic speed in a certain part of an equipment is reached. Gaseous mass flow rate is in proportion to the upstream pressure and not dependent on the downstream pressure. (choked flow) Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 0C, absolute pressure 0. MPa (= 00 kpa = bar), relative humidity 6%. It is stipulated by adding the abbreviation (ANR) after the unit depicting air volume. (standard reference atmosphere) Standard conforming to: ISO 88: 990 Pneumatic fluid powerstandard reference atmosphere, IS 89: 000: Pneumatic fluid powerstandard reference atmosphere () Formula of flow rate It can be indicated by the practical unit as following. When P + 0. b, choked flow P Q = 600 x C (P + 0.) () + t When P + 0. > b, subsonic flow P + 0. P + 0. b P + 0. Q = 600 x C (P + 0.) 9 () b + t Q : Air flow rate [dm /min (ANR)], dm (Cubic decimeter) of SI unit are also allowed to described by l (liter). dm = l.

30 Solenoid Valve Flow Characteristics C Sonic conductance [dm /(s bar)] b Critical pressure ratio [] P Upstream pressure [MPa] P Downstream pressure [MPa] t Temperature [C] Note) Formula of subsonic flow is the elliptic analogous curve. Flow characteristics curve is indicated in the Graph ( For details, please use SMC s Energy Saving Program Example) Obtain the air flow rate for P = 0. [MPa], P = 0. [MPa], t = 0 [C] when a solenoid valve is performed in C = [dm /(s bar)] and b = 0.. According to formula, the maximum flow rate = 600 x x ( ) x Flow rate ratio b = P Equipment C, b 0. P Pressure ratio (P + 0.) / (P + 0.) Graph () Flow characteristics line Q = 600 [dm /min (ANR)] Pressure ratio = = ased on the Graph (), it is going to be if it is read by the pressure ratio as 0.8 and the flow ratio to be b = 0.. Hence, flow rate = Max. flow x flow ratio = 600 x = 0 [dm /min (ANR)] () Test method y attaching a test equipment with the test circuit indicated in Fig. () while maintaining to a certain amount which does not let the upstream pressure go down below 0. MPa, measure the maximum flow to be saturated in the first place. Next, measure this flow rate at 80%, 60%, 0%, 0% and the upstream and downstream pressure. And then, obtain the sonic conductance C from this maximum flow rate. esides that, substitute each data of others for the formula of subsonic flow in order to find b, then obtain the critical pressure ratio b from that average. Pressure gauge or pressure convertor Pressure control equipment ød d Thermometer d ød Differential pressure gauge or differential pressure converter ød Flow control valve Air supply Filter Shut off valve 0d 0d d 0d d Flow meter Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the upstream side Pipe for measuring pressure in the downstream side Fig. () Test circuit based on ISO 68, IS 890 6

31 Solenoid Valve Flow Characteristics. Effective area S () Standards conforming to IS 890: 000: Pneumatic fluid powercomponents using compressible fluids Determination of flow rate characteristics Equipment standards: IS 8: port solenoid valve for pneumatics IS 8: port solenoid valve for pneumatics IS 8: port, port solenoid valve for pneumatics IS 89: Silencer for pneumatics IS 88: Fittings of flexible joint for pneumatics () Definition of flow characteristics Effective area S: is the cross-sectional area having an ideal throttle without friction deduced from the calculation of the pressure changes inside an air tank or without reduced flow when discharging the compressed air in a choked flow, from an equipment attached to the air tank. This is the same concept representing the easy to run through as sonic conductance C (effective area). () Formula of flow rate When P + 0., choked flow P Q = 0 x S (P + 0.) () + t When P + 0. >, subsonic flow P Q = 0 x S (P + 0.) (P P) () + t Conversion with sonic conductance C: S =.0 x C () Q : Air flow rate[dm /min(anr)], dm (cubic decimeter) of SI unit is good to be described by l (liter), too. dm = l S : Effective area [mm ] P : Upstream pressure [MPa] P : Downstream pressure [MPa] t : Temperature [C] Note) Formula for subsonic flow () is only applicable when the critical pressure ratio b is the unknown equipment. In the formula by sonic conductance C (), it is the same formula when b =. () Test method y attaching the equipment for testing with the test circuit shown in Fig. (), discharge air into the atmosphere until the pressure inside the air tank goes down to MPa (0. MPa) from an air tank filled with compressed air of a certain pressure ( MPa) which does not go down below 0.6 MPa. At this time, measure the discharging time and the residual pressure inside the air tank which had been left until it turned to be the normal values, and then determine the effective area S by using the following formula. The volume of air tank should be selected within the specified range by corresponding to the effective area of the equipment being tested. In the case of IS 8, 8, 8, 89, 88, the pressure values are in parentheses and the coefficient of formula is.9. V Ps S =. log0 () (6) t P + 0. T S : Effective area [mm ] V : Air tank capacity [dm ] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Air supply Pressure control equipment Filter Thermometer Shut off valve Pressure switch Control circuit Pressure gauge or pressure converter Timer (Clock) Pressure recorder Solenoid valve Fig. () Test circuit based on IS 890 Power supply Equipment for test Rectifier tube in the upstream side Rectifier tube in the downstream side

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air CAT.EUS0- A -UK Direct Operated Port Solenoid Valve For Water, Oil, Steam, Air New Series VX// Reduction of power consumption ( specification) W. W W W.. W 0. W Low power consumption type: 0. W (Held at

More information

Pilot Operated 2 Port Solenoid Valve For Water, Oil, Air

Pilot Operated 2 Port Solenoid Valve For Water, Oil, Air CT.ES0-9 Pilot Operated Port Solenoid Valve For Water, Oil, ir Reduction of power consumption (DC specification) 6 W.5 W/5.5 W (VXD0 to ) W W (VXD0).5 W 0.5 W New VX D D Series VXD// Solenoid valves for

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series Series VQ0 VCH VDW VQ

More information

Solenoid Valves Flow Characteristics

Solenoid Valves Flow Characteristics Solenoid Valves Flow haracteristics (ow to indicate flow characteristics). Indication of flow characteristics Indication of the flow characteristics in specifications for equipment such as solenoid valve,

More information

Direct acting 2 port solenoid valve (general purpose valve) NC (normally closed) type Port size: Rc1/8, Rc1/4

Direct acting 2 port solenoid valve (general purpose valve) NC (normally closed) type Port size: Rc1/8, Rc1/4 Direct acting port solenoid valve (general purpose valve) Series NC (normally closed) type Port size: Rc/, Rc/ JIS symbol Common specifications Working fluid Working pressure differential range MPa Max.

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

Fluid Control Products. A Constant Flow Of Ideas. 2 Way General Purpose Solenoid Valves

Fluid Control Products. A Constant Flow Of Ideas. 2 Way General Purpose Solenoid Valves Fluid Control Products A Constant Flow Of Ideas 2 Way General Purpose Solenoid Valves T A B L E O F C O N T E N T S Series General Description Pipe Body Material Page 8030 Low Pressure 3/8" - 3/" Brass

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

AB/AG. General purpose direct acting 2, 3 port solenoid valve. (General purpose valve) For air, vacuum, water, oil CONTENTS.

AB/AG. General purpose direct acting 2, 3 port solenoid valve. (General purpose valve) For air, vacuum, water, oil CONTENTS. / (eneral purpose valve) eneral purpose direct acting, 3 port solenoid valve For air, vacuum, water, oil N/ US/ F/ F/ Overview The general purpose valve series enables control of various types of fluids

More information

PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8

PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8 PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8 NC OUT IN 2/2 Series 110 EATURES Compact pilot boxes with direct operated, integrated pilot valves Especially designed

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Soft Start-up Valve Series AV2000/3000/4000/5000

Soft Start-up Valve Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV//4/ AV Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Large effective area (mm

More information

Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve. Oil. MPa. Bracket Standard equipment

Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve. Oil. MPa. Bracket Standard equipment Zero ifferential Pressure Type Pilot Operated Port Solenoid Valve New os ir Water Oil eated water igh temperature oil ompact Lightweight eight Weight %Smaller ( mm) 7%Lighter (, 7 (rass) body) (, esin

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

2/2-way Solenoid Valve for liquids and gases

2/2-way Solenoid Valve for liquids and gases 2/2-way Solenoid Valve for liquids and gases Type 6213EV can be combined with... Coupled spring diaphragm system opened without differential pressure Waterhammer free and low noise HP00 version with increased

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

High Pressure Solenoid Valves

High Pressure Solenoid Valves High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, & other High Pressure Gases High Pressure Cryogenics Flammable Liquids & Gases

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

VALVES N.C. FOR REFRIGERATING SYSTEMS

VALVES N.C. FOR REFRIGERATING SYSTEMS SOLENOID VALVES 11 VALVES N.C. FOR REFRIGERATING SYSTEMS APPLICATIONS The valves illustrated herein are designed for use with refrigerant fluids CFC, HCFC and HFC. OPERATION All valves are normally closed

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector Series 112/212 Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

% ^ ) 1.4 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 1.4 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power 4.4 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /4" to " NPT / 3/ Features Molded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Increased ambient

More information

Direct Operated 2 Port Solenoid Valve New. Height. 10% Smaller. Conventional model. Solenoid coil type

Direct Operated 2 Port Solenoid Valve New. Height. 10% Smaller. Conventional model. Solenoid coil type irect Operated Port Solenoid Valve New Large flow rate low rate 0% ore flow ( ) ody material ir luminum, esin ater/oil/ edium vacuum/steam (rass), Stainless steel ir omparison with S conventional model

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

SOLENOID VALVES SERIES

SOLENOID VALVES SERIES CAD drawing data catalog is available. VALVES GENERAL CATALOG SOLENOID VALVES SERIES INDEX SOLENOID VALVES 010 SERIES Features 61 Basic Models and Configuration 62 Specifications 63 Solenoid Valve/Manifold

More information

2/2-way Solenoid Valve with servo diaphragm

2/2-way Solenoid Valve with servo diaphragm 2/2-way Solenoid Valve with servo diaphragm Type 5282 can be combined with... Pivoted armature pilot drive also with emergency manual override Media separated Circuit function can be modified (NC NO) Adjustable

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D. 1.65 to 9.5 mm

MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D. 1.65 to 9.5 mm MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D. 1.65 to 9.5 mm NC 2/2 Series 284 EATRES Solenoid valve suitable for cutting off the flow of a fluid by pinch or sterile, aseptic, physiological

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

Pilot Operated Pressure Relief Valves Series R4V / R6V

Pilot Operated Pressure Relief Valves Series R4V / R6V Characteristics Series RV / R6V Pilot operated pressure relief valves series RV (DIN 230 Form D) and R6V (DIN 230 Form E) consist of a manually adjusted pilot stage and a seated type main stage. A vent

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

SBM TECHNOLOGY PET Blow Valve Block

SBM TECHNOLOGY PET Blow Valve Block Advanced high pressure seal technology Robust, compact & lightweight design Proven & reliable technology Maintenance & service friendly High flow rate exhaust function Minimal dead space volume (< 35ml)

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series inline Manifold mounting 5 stacking sub-base non plug-in 100 Manual operator 00 Sealed solenoid enclosure Armature 55 56 57

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

3 Way Proportional Pressure Control Valve Nominal diameter 2 Direct operated poppet valves Flange design Low hysteresis

3 Way Proportional Pressure Control Valve Nominal diameter 2 Direct operated poppet valves Flange design Low hysteresis VP0 Way Proportional Pressure Control Valve Nominal diameter Direct operated poppet valves Flange design Low hysteresis Good repeatability High flow capacity at exhaust port Manifold mountable system Compact

More information

24011 series, 3/2 Direct solenoid actuated poppet valve

24011 series, 3/2 Direct solenoid actuated poppet valve 0 series, / > > Port size: / (ISO G or NPT), NAMUR Interface > > Main application: Single and double acting actuators > > TÜV-approval based on type examination DGRL 97//EC and IEC 68, multichannel up

More information

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation Air Catch Sensor Series For Workpiece Placement Confirmation No-contact sensor for confirming workpiece placement, with a configuration that is less affected by supply pressure change. Easy-to-set-up LED

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Process Valves Guide. 2 port valves for various fluids used in a wide variety of applications. Series VX Series VC Series VN. Series SG.

Process Valves Guide. 2 port valves for various fluids used in a wide variety of applications. Series VX Series VC Series VN. Series SG. Series Series VC Series VN Series VCH Series SG 2 port valves for various fluids used in a wide variety of applications Process s Guide PVLF01A-UK Selection based on the Process Fluid IMPORTANT: When choosing

More information

Precision Clean Regulator

Precision Clean Regulator Precision Clean Regulator Series V VEX1 SRF VCHR PVQ T High precision, low flow consumption stainless steel regulator 601 Precision Clean Regulator Series High precision, low flow consumption stainless

More information

Solenoid Valve, Plastic

Solenoid Valve, Plastic Solenoid Valve, Plastic Construction The EMÜ directly controlled 2/2-way plastic solenoid valve has a high performance coil which is hermetically separated from the medium by means of a flexible PTFE bush.

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6111 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6111 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6111 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Model position position Type of actuation

More information

ompact irect Operated Port Solenoid Valve New RoHS Lightweight ir Medium vacuum Water Body material luminum Resin(PPS) 80g luminum/resin(pps) body New ( ) 00 g onventional 37 body ( ) ir Water ompact 5

More information

BVP70, BVPS70 & BVE70 Series

BVP70, BVPS70 & BVE70 Series BVE70 BVPS70 BVP70 BVP70, BVPS70 & BVE70 Series Pneumatically & Electrically Actuated Tube Compression End Style Valves 2 BVP70, BVPS70 & BVE70 Series Ball Valves Ball Valve - MATERIALS OF CONSTRUCTION

More information

VSNG6 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE

VSNG6 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE VSNG6 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE NFPA D03 MOUNTING INTERFACE ISO 4401-03-02-0-94 (CETOP 4.2-4-03-250) SUBPLATE MOUNTING NFPA D03 ISO 4401-03 (CETOP 03) NG6 Pressure max 4060

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

High Pressure Solenoid Valves

High Pressure Solenoid Valves High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, Hydrogen & other High Pressure Gases High Pressure Cryogenics Flammable Liquids

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

Port Solenoid Valve. Series VQZ1000/2000/3000. Compact, High Flow. Power consumption: 0.35 W/0.9 W

Port Solenoid Valve. Series VQZ1000/2000/3000. Compact, High Flow. Power consumption: 0.35 W/0.9 W ort Solenoid Valve Series // Metal Seal Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

Zone Valves and Parts (Honeywell)

Zone Valves and Parts (Honeywell) 28/11/14 B49 Zone Valves - Two Way Fan Coil Zone Valves and Parts (Honeywell) Two-way Fan Coil Valve, the VU53 high pressure zone valves are used to control the flow of hot or chilled water in commercial

More information

type V46, solenoid or pneumatic operated

type V46, solenoid or pneumatic operated SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function

More information

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4 SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Valves

aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Catalog 095 Warning, Offer of Sale! WARNING FAILURE OR IMPROPER SELECTION

More information

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range) Description The sensors provide excellent results even with difficult-to-detect objects, e.g. small or thin parts, wires or bright metals. A variety of types cover a wide range of individual requirements

More information

Micro Mist Separator with Prefilter AMH Model (1) Rated flow (l/min(anr)) Port size (Nominal size B) Weight (kg)

Micro Mist Separator with Prefilter AMH Model (1) Rated flow (l/min(anr)) Port size (Nominal size B) Weight (kg) Micro Mist Separator with Prefilter AMH Series AMH can separate and remove aerosol state oil mist in compressed air and remove carbon or dust of more than 0.01µm. It should be used as prefilter of compressed

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

Series 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244 According to DIN and US standards

Series 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244 According to DIN and US standards Series 2 Pneumatic Control Valves Type 3244-1 Type 3244-7 Three-way Valve Type 3244 According to DIN US stards Application Mixing or flow-diverting valves designed for use in process engineering industrial

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Pressure Sensors. for neutral and slightly aggressive liquids and gases

Pressure Sensors. for neutral and slightly aggressive liquids and gases 1909P01 Pressure Sensors for neutral and slightly aggressive liquids and gases QBE2003-P QBE2103-P High-precision measuring Measuring range 0 to 60 bar relative Supply voltage AC 24 V / DC 12...33 V or

More information

Proportional pressure relief valve with position feedback (Lvdt AC/AC)

Proportional pressure relief valve with position feedback (Lvdt AC/AC) Proportional pressure relief valve with position feedback (Lvdt AC/AC) RE 29150/07.05 1/10 Type DBETBX Nominal size 6 Unit series 1X Maximum working pressure P 315 bar, T 2 bar Nominal flow rate Q nom

More information

3/2-way pneumatic cartridge solenoid valve

3/2-way pneumatic cartridge solenoid valve 3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as

More information

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback RE 29163/07.05 1/12 Type DBEBE10Z Nominal size 10 Unit series 1X Maximum working pressure A, B,

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

Auto Reset Gas Solenoid Valves GV-VMR

Auto Reset Gas Solenoid Valves GV-VMR Page 1 of 5 Description The VMR type valve is a fast opening single-stage solenoid valve, normally closed. This type of device is suitable for air or gas blocking and releasing controls, required in gas

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

Sporlan V-Series Ruby Seat Solenoid Valves

Sporlan V-Series Ruby Seat Solenoid Valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Sporlan V-Series Ruby Seat Solenoid Valves RACE Catalogue 30-10-8 UK,

More information

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable

More information

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double 4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor

More information

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

SOLENOID VALVE FOR REFRIGERATING SYSTEMS SOLENOID VALVE FOR REFRIGERATING SYSTEMS FROM UALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel uality Range of Products

More information

Valves. Sub-Base Mounted Valves to ISO 5599/2

Valves. Sub-Base Mounted Valves to ISO 5599/2 Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great

More information

Pressure relief valves type ARAM two stage, in line mounting - G 3/4" and G 1 1 /4" threaded ports

Pressure relief valves type ARAM two stage, in line mounting - G 3/4 and G 1 1 /4 threaded ports www.atos.com Table C04520/E Pressure relief valves type ARAM two stage, in line mounting G 3/4" and G 1 1 /4" threaded ports ARAM20/20...E ARAM32.../V ARAM are two stage pressure relief valves with balanced

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A609/E Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls PVPCCH4046 PVPC are variable displacement axial piston pumps for high pressure operation,

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

High-quality pressure transmitter for general industrial applications Model S-10

High-quality pressure transmitter for general industrial applications Model S-10 Electronic pressure measurement High-quality pressure transmitter for general industrial applications Model S-10 WIKA data sheet PE 81.01 for further approvals see page 4 Applications Machine building

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

Form DVA-10 Rev. 6/10

Form DVA-10 Rev. 6/10 Form DVA-10 Rev. 6/10 DASH 1... 5-13 Cutaway Drawing... 6 Color Coding... 3,4,8 Mounting Styles... 5 Electrical Connector Options... 6 Temperature Range... 7 Electrical Specifications... 7 Part Number

More information

BERMAD Waterworks. High Pressure, Booster Pump Control Valve Active Check Valve. 800 Series. Model 840. Features and Benefits

BERMAD Waterworks. High Pressure, Booster Pump Control Valve Active Check Valve. 800 Series. Model 840. Features and Benefits High Pressure, Booster Pump Control Valve Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery

More information

HANDBOOK SOLENOID VALVE FOR REFRIGERATING SYSTEMS AND INDUSTRIAL PURPOSES. ed. 001-VS-ENG 1

HANDBOOK SOLENOID VALVE FOR REFRIGERATING SYSTEMS AND INDUSTRIAL PURPOSES. ed. 001-VS-ENG 1 HANDBOOK SOLENOID VALVE FOR REFRIGERATING SYSTEMS AND INDUSTRIAL PURPOSES 1 INDEX Normally closed solenoid valves for refrigerating systems Normally open solenoid valves for refrigerating systems Coils

More information