Pilot Operated 2 Port Solenoid Valve for Dry Air

Size: px
Start display at page:

Download "Pilot Operated 2 Port Solenoid Valve for Dry Air"

Transcription

1 Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series Series VQ0 VCH VDW VQ LVM High frequency operation possible High speed response 7 ms or less (VQ0), 0 ms or less () (High speed response type without light/surge voltage suppressor at the supply pressure of 0.5 MPa) Long operating life Easy piping with One-touch Fittings Dusttight low jetproof enclosure (IP65) compliant in DIN terminal type. Application: Air-blow, Blow-off of workpiece, etc. 43

2 Pilot Operated For Dry Air Port Solenoid Valve Series VQ0/30 Single Unit [Option] How to Order Valves VQ A G C6 Series/ Orifice diameter Symbol 3 N.C. Series VQ0 Valve type (OUT) Option : None F: With bracket CE-compliant Q CE-compliant Made to Order specifications (Refer to the table below) A: Single unit (IN) Body type Manual override None Note) Slotted locking type B (tool required) Note) Only normally closed DIN terminal in-line style is applicable. L: Type L (VQ0 only) Note) If ordering both options, indicate LF. M: For manifold Note ) G: Grommet Coil voltage 00 VAC (50/60 Hz) 00 VAC (50/60 Hz) 0 VAC (50/60 Hz) 4 VDC VDC Other special voltage Note ) Please consult with SMC for special voltages. Note ) There is polarity for DC voltage (with power-saving circuit type). Y: DIN terminal YO: DIN terminal without connector Electrical entry Electricity circuit Symbol DC voltage With power-saving circuit (With surge voltage suppressor protection circuit) With power-saving circuit Z (With light/surge voltage suppressor protection circuit) Note) High speed response type H (Without energy-saving, light/surge voltage suppressor circuit) Note) H is available only for DC voltage and cannot be energized continuously. Made to Order Specifications Oil-free specifications VQ A 3M VQ A 3M Seal material fluororubber/oil-free specifications VQ A 3 M Note) Not available for manual operation. Port size Symbol Port size C6 C8 C0 C One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø0 One-touch fitting for ø AC voltage With full wave rectifier circuit (With surge voltage suppressor protection circuit) With full wave rectifier circuit (With light/surge voltage suppressor protection circuit) VQ0 X(-Q) X5(-Q) X3(-Q) Please contact SMC for further specifications, delivery and price. Note) Please consult with SMC when using. Not available for manual operation. Seal material fluororubber specifications A 44

3 Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Standard Specifications VQ0 Valve specifications Series Valve construction Fluid Ambient and fluid temperature Lubrication Manual override Impact resistance/vibration resistance Enclosure Internal leakage cm 3 /min Exterior leakage cm 3 /min Mounting orientation Weight VQ0 port poppet pilot operated Note ) Air Note ) 0 to 50 C Not required Note 3) Slotted locking type (tool required) 50/30 m/s Note 4) Note 5) Dustproof 5 or less 5 or less Unrestricted 46 g 80 g Symbol (OUT) (IN) N.C. Electric specifications Coil rated voltage Allowable voltage fluctuation Coil insulation type VDC, 4 VDC, 00 VAC, 0 VAC, 00 VAC ±0% of rated voltage Class B or equivalent Power DC voltage (with power-saving circuit) Inrush:.9 W, Holding: 0.6 W consumption DC voltage (without power-saving circuit).9 W (Current value) AC VA Electrical entry Grommet, DIN terminal Note ) This product is for dry air. Use in clean air, and be sure that drain and oil content does not flow into the product. Note ) Use dry air to prevent condensation when operating at low temperatures. Note 3) Manual override is available only for DIN terminal type. Note 4) Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 000 Hz. Test was performed at both energized and de-energized states to the axis and right angle directions of the main valve and armature (value at the initial state). Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature for both energized and de-energized states (value at the initial state). Note 5) DIN terminal type: Applicable to dusttight and low jetproof (IP65). Characteristic Specifications Series VQ0 Port size ø6 ø8 ø0 ø Flow characteristics C [dm 3 /(s bar)] b Cv Min. operating pressure differential Note 3) 0.0 MPa Max. operating pressure 0.6 MPa 0.5 MPa Note ) Note ) Electricity circuit With power-saving circuit High speed response type With power-saving circuit High speed response type Note ) Response time ON OFF 0 ms or less 5 ms or less 7 ms or less 5 ms or less 5 ms or less 5 ms or less 0 ms or less 5 ms or less VCH VDW VQ LVM Construction Note ) JIS B 8375 (value of DC voltage specifications at 0.5 MPa supply pressure) (Value of high response time is subject to change upon pressure, quality of air.) Note ) It cannot be used when energized continuously. Note 3) If a restrictor (nozzle, etc.) is mounted on the outlet side piping, the pressure differential when ON is smaller. Be sure that the pressure differential does not drop below 0.0 MPa. Additionally, take great care when used for the ejector supply, etc. w e q r t y u Component Parts No Description Solenoid coil Body Fixed armature Armature Return spring Poppet Diaphragm assembly Material Resin Stainless steel Stainless steel Stainless steel NBR H NBR, Resin 45 C

4 Series VQ0/30 Dimensions: Series VQ0 In-line Type: Grommet (G) VQA-G- - Mounting holes x ø3. through Bracket mounting holes x ø3. through Light Lead wire length Approx. 300 P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 Dotted line: Bracket mounting style (-F) 46

5 Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Dimensions: Series VQ0 Type L: Grommet (G) VQA-G- -L Light Lead wire length Approx. 300 VCH VDW P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 VQ LVM C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 x ø3. mounting hole Dotted line: Bracket mounting style (-LF) 47 A

6 Series VQ0/30 Dimensions: Series VQ0 In-line Type: DIN terminal (Y) VQA-Y- - Mounting hole x ø3. through Bracket mounting hole x ø3. through Manual override Applicable cable O.D. ø3.5 to ø7.0 mm P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 Dotted line: Bracket mounting style (-F) 48

7 Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Dimensions: Series In-line Type: Grommet (G) VQ3A-G- - Mounting hole x ø4.3 through Bracket mounting hole x ø4.5 through Light Lead wire length Approx. 300 VCH VDW VQ LVM P port C0: One-touch fitting for ø0 C: One-touch fitting for ø C0: One-touch fitting for ø0 C: One-touch fitting for ø Dotted line: Bracket mounting style (-F) 49

8 Series VQ0/30 Dimensions: Series DIN terminal (Y) VQ3A-Y- - Mounting hole x ø4.3 through Bracket mounting hole x ø4.5 through Manual override Applicable cable O.D. ø3.5 to ø7.0 mm P port C0: One-touch fitting for ø0 C: One-touch fitting for ø C0: One-touch fitting for ø0 C: One-touch fitting for ø Dotted line: Bracket mounting style (-F) 430

9 Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 How to Order Manifold VVQ 08 3 Series VQ0 Stations 0 station 0 0 stations Option D DO P port/thread type 00N 00T 00F CE-compliant Q CE-compliant Rc 3/8 NPT 3/8 NPTF 3/8 G 3/8 None DIN rail mounting DIN rail mounting (Without DIN rail) How to Order Manifold Assembly Enter the mounting valve and option part numbers under the manifold base part number. <Ordering Example> VVQ-05 (-Q) set Manifold part No. VQM-5G-C6 (-Q) 4 sets Valve part No. (Stations to 4) VQM-5G-C8 (-Q) set Valve part No. (Station 5) is the symbol for assembly. Add a in front of the part numbers for solenoid valves, etc., to be mounted. Stations 3 U side D side Enter together in order, counting from station on the D side. [Option] P How to Order Valves (For Manifold) Series/ Orifice diameter Symbol Series VQ0 3 Valve specifications M Manifold G Y YO Valve Type N.C. (OUT) VQ M G C6 (IN) Electrical entry Grommet DIN terminal DIN terminal (without connector) Note ) Coil voltage 00 VAC (50/60 Hz) 00 VAC 0 VAC 4 VDC VDC Other special voltage Note ) Please consult with SMC for special voltages. Note ) There is polarity for DC voltage (with power-saving circuit type). Electricity circuit Symbol Z H Note) Port size Symbol C6 C8 C0 C DC voltage With power-saving circuit (with surge voltage suppressor protection circuit) With power-saving circuit (with light/surge voltage suppressor protection circuit) High speed response type (without energy-saving, light/surge voltage suppressor circuit) Made to Order specifications Q (Refer to the table below) Port size One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø0 One-touch fitting for ø VQ0 Manual override None B Note) Slotted locking type (tool required) Note) Only normally closed DIN terminal in-line style is applicable. Note) H is available only for DC voltage and cannot be energized continuously. CE-compliant CE-compliant AC voltage With full wave rectifier circuit (with surge voltage suppressor protection circuit) With full wave rectifier circuit (with light/surge voltage suppressor protection circuit) VCH VDW VQ LVM Made to Order Specifications Please contact SMC for further specifications, delivery and price. Oil-free specifications VQ 3 M X (-Q) Note) Please consult with SMC when using. Not available for manual operation. Seal material fluororubber specifications VQ 3 M X5 (-Q) 43 A

10 Series VQ0/30 Dimensions Plug lead unit manifold (VVQ- ) Mounting hole x ø4.5 through C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 x Rc 3/8 DIN rail mounting 4 x M3 x 0.5 Dotted line: DIN rail mounting (-D) Dimensions L L L L3 L4 L5 n Formulas L = (n ) x L = L 0 L3 = L4 0.5 L5 = L. n: Station (Max. 0)

11 Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Dimensions Plug lead unit manifold (VVQ3- ) Mounting hole x ø4.5 through C0: One-touch fitting for ø0 C: One-touch fitting for ø x Rc 3/8 VCH VDW VQ LVM DIN rail mounting 4 x M3 x 0.5 Dotted line: DIN rail mounting (-D) Formulas L = (n ) x L = L 0 L3 = L4 0.5 L5 = L. Dimensions n: Station (Max. 0) L n L L L L L

12 Series VQ0/30 Single Unit Option Bracket assembly (with mounting screws) For fixing this solenoid valve. Type VQ0 Grommet in-line type VQ0 Grommet L type, DIN terminal type DIN terminal L type Bracket assembly AXT835-3A AXT835-3A- AXT835-3A-3 AXT837-3A (Mounting screws, pcs.) M3 x 45 M3 x 40 M3 x 35 M4 x 45 Manifold Option DIN rail AXT00-DR- L.5 (Pitch) Suffix the number from DIN rail dimensions table below. Refer to the dimension drawing for each manifold for L dimension Each manifold can be mounted on a DIN rail. Order with the option symbol -D to specify DIN rail mounting style. The DIN rail is approximately 30 mm longer than the length of manifold. L dimension Series VQ0 Stations No. L Series Stations No L DIN rail mounting bracket VVQZ00-DB-5 This bracket is used for mounting the manifold on the DIN rail. DIN rail mounting bracket is attached on the manifold. set of DIN rail mounting brackets for manifold includes brackets. Blanking plate assembly (with O-ring and mounting screws) Mount a blank plate on valve manifold when a valve is disassembled for maintenance purposes, or when spare valve unit is supposed to be mounted in the future. Series VQ0 Blanking plate assembly AXT835-35A AXT837-35A (O-ring) OR H OR H (Mounting screws, pcs.) M3 x 6 M4 x 6 434

13 Series VQ0/30 Specific Product Precautions Be sure to read before handling. Refer to front matter 4 for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for Fluid Control Precautions. Warning Selection. Air quality This product is for dry air. Drain, oil, etc. in the air may result in faulty operation. Use clean (dry) air.. Pressure differential If a restrictor (nozzle, etc.) is mounted on the outlet side, the outlet side pressure differential at the inlet side is smaller. Be sure the pressure differential when ON does not drop below 0.0 MPa. Manual Override Warning Regardless of electric signals to the solenoid valve, the manual override is used for switching the main valve. (DIN terminal only.) Push the manual override Slotted locking type (tool required) button with a small flat head screwdriver until it stops. Turn it in the counterclockwise direction at ø to lock the manual. Turn it right to release. LED PUSH Timer circuit TURN LOCK Connection and Electrical Circuit Caution Black ( ) DC Blue (00 VAC) Red (00 VAC) Red (+) DC Blue (00 VAC) Red (00 VAC) With DC voltage power-saving circuit (with polarity) Lead wire color DIN connector Red (+) SOL. Connection and Electrical Circuit Caution Power wave form of power-saving type (Rated voltage at 4 VDC) Applied voltage 4 V 0 V 0 to 0 ms.9 W Power-saving 0.6 W 0 W AC circuit Lead wire color DIN connector Blue (00 VAC), Red (00 VAC) Blue (00 VAC), Red (00 VAC) Caution Valve Mounting When mounting the valve, secure with brackets. When mounting it directly, tighten the mounting screws with the appropriate torque (0.7 to 0.8 N m). Mounting screw Tightening torque 0.7 to 0.8 N m LED When Energizing Continuously for Long Period of Time SOL. Caution When energizing continuously, choose the option of an energysaving circuit specifications. High speed response type (with no energy-saving circuit) cannot be energized continuously. VCH VDW VQ LVM Black ( ) i i i: Inrush current, i: Holding current DC (with power-saving circuit) specifications is designed to reduce the power consumption at holding to achieve powersaving by circuit shown above. Refer to below power wave form. 435

14 Series VQ0/30 Specific Product Precautions Be sure to read before handling. Refer to front matter 4 for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for Fluid Control Precautions. How to Wire DIN Terminal Caution ISO#: Based on DIN 43650C (Pin gap 8 mm) Connection. Loosen the tightening screw and pull the connector off of the solenoid valve.. After removing the tightening screw, divide the terminal block and housing by prying open the slot area of the lower part of the terminal block open with a screwdriver. 3. Loosen the terminal screws of the block and insert stripped lead wires in accordance with the wiring diagram. Secure each wire by re-tightening the terminal screw (In the case of terminal : (+), : (-) DC) 4. Tighten the ground nut to secure the cable wire. Change of electrical entry Wire entry can be changed by mounting the housing in either direction (four directions at every 90 ) after dividing the terminal block and the housing. For the indicator lighted style, be careful not to damage the light with the lead wire of the cable. Precautions Insert a connector straight or pull it out straight, using caution it does not be tilted. Applicable cable Cord O.D.: ø3.5 to ø7 (Reference) 0.5 mm -core and 3-core wire equivalent to JIS C Ground nut Tightening torque.65 to.5 N m Washer Grommet (Rubber) (Voltage symbol) Refer to the following table Tightening torque 0. to 0.5 N m Terminal screw (3 positions) Tightening screw Tightening torque 0.3 to 0.4 N m Housing (Position for light mounting) Terminal block Shaved part DIN Terminal Part No. (Based on DIN) Without indicator light SY With Indicator Light Rated voltage Voltage symbol Part no. 4 VDC VDC 00 VAC 00 VAC 0 VAC 4 V V 00 V 00 V 0 V SY SY SY SY SY DIN Terminal Circuit with Indicator Light AC circuit How to Wire DIN Terminal NL R NL: Neon light R: Resistor Manifold How to Mount/Remove from DIN Rail Caution Removing procedure. Loosen the clamp screw on the A side of both ends of the manifold.. Lift the A side of the manifold off the DIN rail and slide it in the direction of the arrow. Mounting procedure. Hook the mounting hook on the B side of the manifold base to the DIN rail.. Press down side A and mount the end plate on the DIN rail. Tighten the clamp screw on side B of the end plate. (Tightening torque: 0.3 to 0.4 N m). Caution Valve Mounting DC circuit LED R LED: Light emitting diode R: Resistor After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque (0.7 to 0.8 N m). A Manifold mounting screw B Manifold mounting screw 436

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double 4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

SOLENOID VALVES SERIES

SOLENOID VALVES SERIES CAD drawing data catalog is available. VALVES GENERAL CATALOG SOLENOID VALVES SERIES INDEX SOLENOID VALVES 010 SERIES Features 61 Basic Models and Configuration 62 Specifications 63 Solenoid Valve/Manifold

More information

Direct Operated 3 Port Solenoid Valve For Air, Water, Oil, Steam

Direct Operated 3 Port Solenoid Valve For Air, Water, Oil, Steam CAT.ES0-6 Direct Operated Port Solenoid Valve For Air, Water, Oil, Steam Reduced power consumption ( specification). W. 8 W W 0. W.. W 6 W New VX Series VX/ / Reduced power consumption Improved corrosion

More information

Soft Start-up Valve Series AV2000/3000/4000/5000

Soft Start-up Valve Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV//4/ AV Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Large effective area (mm

More information

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation Air Catch Sensor Series For Workpiece Placement Confirmation No-contact sensor for confirming workpiece placement, with a configuration that is less affected by supply pressure change. Easy-to-set-up LED

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector Series 112/212 Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

BVP70, BVPS70 & BVE70 Series

BVP70, BVPS70 & BVE70 Series BVE70 BVPS70 BVP70 BVP70, BVPS70 & BVE70 Series Pneumatically & Electrically Actuated Tube Compression End Style Valves 2 BVP70, BVPS70 & BVE70 Series Ball Valves Ball Valve - MATERIALS OF CONSTRUCTION

More information

Direct acting 2 port solenoid valve (general purpose valve) NC (normally closed) type Port size: Rc1/8, Rc1/4

Direct acting 2 port solenoid valve (general purpose valve) NC (normally closed) type Port size: Rc1/8, Rc1/4 Direct acting port solenoid valve (general purpose valve) Series NC (normally closed) type Port size: Rc/, Rc/ JIS symbol Common specifications Working fluid Working pressure differential range MPa Max.

More information

Port Solenoid Valve. Series VQZ1000/2000/3000. Compact, High Flow. Power consumption: 0.35 W/0.9 W

Port Solenoid Valve. Series VQZ1000/2000/3000. Compact, High Flow. Power consumption: 0.35 W/0.9 W ort Solenoid Valve Series // Metal Seal Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

1.8 w 101.2. 3 Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

1.8 w 101.2. 3 Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8

PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8 PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8 NC OUT IN 2/2 Series 110 EATURES Compact pilot boxes with direct operated, integrated pilot valves Especially designed

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

100 kpa to 1.0 MPa Both positive pressure and vacuum pressure can be used with one unit!

100 kpa to 1.0 MPa Both positive pressure and vacuum pressure can be used with one unit! In-line Air Filter Series For tubing sizes ø2 and ø3.2, refer to Air Suction Filter/Series on SMC website. Operating pressure range kpa to 1. MPa Both positive pressure and vacuum pressure can be used

More information

SBM TECHNOLOGY PET Blow Valve Block

SBM TECHNOLOGY PET Blow Valve Block Advanced high pressure seal technology Robust, compact & lightweight design Proven & reliable technology Maintenance & service friendly High flow rate exhaust function Minimal dead space volume (< 35ml)

More information

Fluid Control Products. A Constant Flow Of Ideas. 2 Way General Purpose Solenoid Valves

Fluid Control Products. A Constant Flow Of Ideas. 2 Way General Purpose Solenoid Valves Fluid Control Products A Constant Flow Of Ideas 2 Way General Purpose Solenoid Valves T A B L E O F C O N T E N T S Series General Description Pipe Body Material Page 8030 Low Pressure 3/8" - 3/" Brass

More information

RPE3-04. Functional Description HA 4014 09/2013. Directional Control Valves Solenoid Operated. Replaces HA 4014 10/2010

RPE3-04. Functional Description HA 4014 09/2013. Directional Control Valves Solenoid Operated. Replaces HA 4014 10/2010 Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) HA 4014 09/2013 Replaces HA 4014 10/2010 4/3-, 4/2- way directional control valves with solenoid

More information

STC 2S Series Solenoid Valves

STC 2S Series Solenoid Valves STC 2S025-050 Series Solenoid Valves 2S025-050 Series Solenoid Valve Specifications Valve Model 2S025-1/4 2S035-1/4 2S040-3/8 2S050-1/4 2S050-3/8 Valve Type Action 2 Way, Normally Closed (NC) Direct Acting,

More information

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO P-EX01-A Solenoid Valve (with M Connector) Conforming to ISO 1507-1, Large capacity EVS1-01 (Size: 01) EVS1-0 (Size: 0) Light weight Size 01 (-position): 0.6kg Size 0 (-position): 0.18kg Flow rate 1000L/min

More information

Precision Clean Regulator

Precision Clean Regulator Precision Clean Regulator Series V VEX1 SRF VCHR PVQ T High precision, low flow consumption stainless steel regulator 601 Precision Clean Regulator Series High precision, low flow consumption stainless

More information

AB/AG. General purpose direct acting 2, 3 port solenoid valve. (General purpose valve) For air, vacuum, water, oil CONTENTS.

AB/AG. General purpose direct acting 2, 3 port solenoid valve. (General purpose valve) For air, vacuum, water, oil CONTENTS. / (eneral purpose valve) eneral purpose direct acting, 3 port solenoid valve For air, vacuum, water, oil N/ US/ F/ F/ Overview The general purpose valve series enables control of various types of fluids

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Model position position Type of actuation

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

Series ZYY/ZYX. Ejector Valve Unit. Ejector valve unit suitable for vacuum adsorption systems

Series ZYY/ZYX. Ejector Valve Unit. Ejector valve unit suitable for vacuum adsorption systems CT.E831- Ejector Valve Unit Series ZYY/ZYX Nozzle diameters ø.7, ø1. Types S: Standard type : arge flow type Ejector valve unit suitable for vacuum adsorption systems ( combination of solenoid valve for

More information

% ^ ) 1.4 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 1.4 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power 4.4 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /4" to " NPT / 3/ Features Molded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Increased ambient

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Pressure relief valves type ARAM two stage, in line mounting - G 3/4" and G 1 1 /4" threaded ports

Pressure relief valves type ARAM two stage, in line mounting - G 3/4 and G 1 1 /4 threaded ports www.atos.com Table C04520/E Pressure relief valves type ARAM two stage, in line mounting G 3/4" and G 1 1 /4" threaded ports ARAM20/20...E ARAM32.../V ARAM are two stage pressure relief valves with balanced

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Pressure relief valves type AGAM two stage, subplate mounting - ISO 6264 size 10, 20 and 32

Pressure relief valves type AGAM two stage, subplate mounting - ISO 6264 size 10, 20 and 32 www.atos.com Table C06619/E Pressure relief valves type AGAM two stage, subplate mounting ISO 6264 size 10, 20 and 32 1 MODEL CODE AGAM10/11...E AGAM20/.../V AGAM are two stage pressure relief valves with

More information

VALVES N.C. FOR REFRIGERATING SYSTEMS

VALVES N.C. FOR REFRIGERATING SYSTEMS SOLENOID VALVES 11 VALVES N.C. FOR REFRIGERATING SYSTEMS APPLICATIONS The valves illustrated herein are designed for use with refrigerant fluids CFC, HCFC and HFC. OPERATION All valves are normally closed

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A609/E Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls PVPCCH4046 PVPC are variable displacement axial piston pumps for high pressure operation,

More information

2/2-way Solenoid Valve with servo diaphragm

2/2-way Solenoid Valve with servo diaphragm 2/2-way Solenoid Valve with servo diaphragm Type 5282 can be combined with... Pivoted armature pilot drive also with emergency manual override Media separated Circuit function can be modified (NC NO) Adjustable

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series inline Manifold mounting 5 stacking sub-base non plug-in 100 Manual operator 00 Sealed solenoid enclosure Armature 55 56 57

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No. RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in

More information

STC 3S012-020-A Series Solenoid Valves

STC 3S012-020-A Series Solenoid Valves STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

VSNG6 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE

VSNG6 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE VSNG6 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE NFPA D03 MOUNTING INTERFACE ISO 4401-03-02-0-94 (CETOP 4.2-4-03-250) SUBPLATE MOUNTING NFPA D03 ISO 4401-03 (CETOP 03) NG6 Pressure max 4060

More information

Pilot Operated Pressure Relief Valves Series R4V / R6V

Pilot Operated Pressure Relief Valves Series R4V / R6V Characteristics Series RV / R6V Pilot operated pressure relief valves series RV (DIN 230 Form D) and R6V (DIN 230 Form E) consist of a manually adjusted pilot stage and a seated type main stage. A vent

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 OD Tube 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Classification Contact form Mounting method Terminals Rated voltage Model Equipped with operation indicator and diode to absorb coil surge.

Classification Contact form Mounting method Terminals Rated voltage Model Equipped with operation indicator and diode to absorb coil surge. Terminal Relay CSM_G6B-4 ND_DS_E_3_1 Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges,

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Valves. Sub-Base Mounted Valves to ISO 5599/2

Valves. Sub-Base Mounted Valves to ISO 5599/2 Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great

More information

Unpacking. Fitting the camera inside the housing. 290B Outdoor housing. In the box with the 290B housing you will find a small plastic bag containing:

Unpacking. Fitting the camera inside the housing. 290B Outdoor housing. In the box with the 290B housing you will find a small plastic bag containing: Unpacking In the box with the 290B housing you will find a small plastic bag containing: 1 2 4 5 3 No. 1. One large allen key 2. One small allen key 3. Two locking screws 4. Four M8 wall fixings 5. Four

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air CAT.EUS0- A -UK Direct Operated Port Solenoid Valve For Water, Oil, Steam, Air New Series VX// Reduction of power consumption ( specification) W. W W W.. W 0. W Low power consumption type: 0. W (Held at

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

Operator's manual Straight line wiper Ocean Function of panel type Ocean: 2.)Installation: Wiper and cable installation

Operator's manual Straight line wiper Ocean  Function of panel type Ocean: 2.)Installation: Wiper and cable installation Operator's manual Straight line wiper Ocean The Seematz wiper housing consists of sea water resistant aluminium Almg 3. All other metal parts are made of stainless steel or brass. All colored parts are

More information

60% compared to existing model)

60% compared to existing model) ort Solenoid Valve Series VQ000/000 Metal Seal ubber Seal ower saving Standard: 0. W [Option] ohs SJ 0% compared to existing model) High-pressure ( Ma, Metal seal): 0.9 W SV (educed by J SZ VF V S0700

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

E2K-C. Long-distance Capacitive Proximity Sensor. Ordering Information. Sensors. Accessories (Order Separately) Mounting Brackets.

E2K-C. Long-distance Capacitive Proximity Sensor. Ordering Information. Sensors. Accessories (Order Separately) Mounting Brackets. Long-distance Capacitive Proximity Sensor Capacitive Proximity Sensor with Adjustable Sensitivity Detects both metallic and non-metallic objects (glass, lumber, water, oil, plastic, etc.) without direct

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

MGC 1 Multi Gun Control

MGC 1 Multi Gun Control E Operating instructions and Spare Parts List Multi Gun Control GUNS 2 3 4 5 6 7 8 00 90 80 70 60 50 40 30 20 0 kv 000 900 800 700 600 500 400 300 200 00 µa GEMA VOLSTATIC 0 An ITW Company 3 4 Table of

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

3 Way Proportional Pressure Control Valve Nominal diameter 2 Direct operated poppet valves Flange design Low hysteresis

3 Way Proportional Pressure Control Valve Nominal diameter 2 Direct operated poppet valves Flange design Low hysteresis VP0 Way Proportional Pressure Control Valve Nominal diameter Direct operated poppet valves Flange design Low hysteresis Good repeatability High flow capacity at exhaust port Manifold mountable system Compact

More information

3/4/5 Port Solenoid Valves Precautions 1 Be sure to read this before handling.

3/4/5 Port Solenoid Valves Precautions 1 Be sure to read this before handling. Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures or temperatures, etc.,

More information

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

DIAMOND Retractable Rodding Robot Model SPRAYROD-R 2004-12-21 2 1 (23) DIAMOND Retractable Rodding Robot Model SPRAYROD-R 2004-12-21 2 2 (23) Table of contents 1 TECHNICAL DESCRIPTION...4 1.1 MAIN DETAILS...5 1.2 COMPONENTS DESCRIPTION...5 1.2.1 Pneumatic

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

24011 series, 3/2 Direct solenoid actuated poppet valve

24011 series, 3/2 Direct solenoid actuated poppet valve 0 series, / > > Port size: / (ISO G or NPT), NAMUR Interface > > Main application: Single and double acting actuators > > TÜV-approval based on type examination DGRL 97//EC and IEC 68, multichannel up

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Long-distance capacitive proximity sensor. Ordering Information EB-74. Sensors. Accessories (Order Separately) Mounting Brackets. Unshielded.

Long-distance capacitive proximity sensor. Ordering Information EB-74. Sensors. Accessories (Order Separately) Mounting Brackets. Unshielded. Long-distance capacitive proximity sensor Capacitive Proximity Sensor with Adjustable Sensitivity Detects both metallic and non-metallic objects (glass, lumber, water, oil, plastic, etc.) without direct

More information

VAL-74. V40/V41 Mini ISO Star Valves 2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO / VDMA Size 18 mm VALVES

VAL-74. V40/V41 Mini ISO Star Valves 2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO / VDMA Size 18 mm VALVES V40/V4 Mini ISO Star Valves 2x/2, /2 and /, Solenoid and Pilot Actuated ISO 407- / VDMA 24 6 Size 8 mm Compact design and high performance Flexible Sub-base system True multipressure system Sandwich regulators

More information

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product 996A106032 TUM 1024 REV. I 11.04.2016 Tranberg AS P.O. Box 8033 N-4068 Stavanger

More information

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

SOLENOID VALVE FOR REFRIGERATING SYSTEMS SOLENOID VALVE FOR REFRIGERATING SYSTEMS FROM UALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel uality Range of Products

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

E2A3. Extra long distance for increased protection and sensing performance. Long Distance Cylindrical Proximity Sensor. Ordering Information

E2A3. Extra long distance for increased protection and sensing performance. Long Distance Cylindrical Proximity Sensor. Ordering Information Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

REMOTE MOUNT SOLENOID DRIVER (0-10 VDC Input Version)

REMOTE MOUNT SOLENOID DRIVER (0-10 VDC Input Version) REMOTE MOUNT SOLENOID DRIVER (0-10 VDC Input Version) Part No.: PCB Board - RSD-PCB-10V-x DIN Rail Mount RSD-DR-10V-x Packaged Driver (board installed in housing assembly) Available with no cable - RSD-SMB-10V-x-00

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

type V46, solenoid or pneumatic operated

type V46, solenoid or pneumatic operated SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function

More information

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables. Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range) Description The sensors provide excellent results even with difficult-to-detect objects, e.g. small or thin parts, wires or bright metals. A variety of types cover a wide range of individual requirements

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

TECHNICAL DATA SHEET 600 Series Electric Actuators

TECHNICAL DATA SHEET 600 Series Electric Actuators TECHNICAL DATA SHEET 600 Series Electric Actuators 2 Otter Court, Raymond, New Hampshire 03077 Tel. (603) 895-4761 FAX (603) 895-6785 www.geminivalve.com DESCRIPTION The 600 Series electric actuators can

More information