Fluid Control Products. A Constant Flow Of Ideas. 2 Way General Purpose Solenoid Valves

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Fluid Control Products. A Constant Flow Of Ideas. 2 Way General Purpose Solenoid Valves"

Transcription

1 Fluid Control Products A Constant Flow Of Ideas 2 Way General Purpose Solenoid Valves

2 T A B L E O F C O N T E N T S Series General Description Pipe Body Material Page 8030 Low Pressure 3/8" - 3/" Brass and Stainless Steel 1 800/8215 High Flow Gas/ High Air Valves 8210 General Service 3/8" - 2 1/2" 3/8" - 3" Aluminum 5 Brass and Stainless Steel 8221 Slow Closing 3/8" - 2 1/2" Brass High Pressure 1/" - 3/" 8225/8280 Sub-Miniature 1/8" Brass and Stainless Steel Brass and Stainless Steel Dispensing/Bib Connection 1/" Plastic /8263 General Service Compact 1/8" - 3/8" Brass and Stainless Steel 27 These solenoid valves have one inlet and one outlet, and are used to permit and shut off fluid flow. Two Types of Operations Apply: Normally Closed Fluid is shut off when the coil is de-energized, flows through the valve when the coil is energized. Normally Open Fluid flows through the valve when the coil is de-energized, shuts off when the coil is energized. Two Types of Constructions Apply: Direct Acting When the solenoid is energized, the core directly opens the orifice of a Normally Closed valve or closes the orifice in a Normally Open valve. The valve will operate at pressures from 0 psi to its rated maximum. The force needed to open the valve is proportional to the orifice size and fluid pressure. As orifice size increases, so does the required force. To open larger orifices without increasing solenoid size, internal pilots are used. Internally Piloted These valves use line pressure to assist operation. When the coil is de-energized (on a Normally Closed valve), the pilot orifice is closed and line pressure is applied to the top of the piston or diaphragm through the bleed orifice, closing the valve. When the coil is energized, the core opens the pilot orifice, relieving pressure from the diaphragm or piston. Line pressure, alone, opens the valve by lifting the diaphragm or piston off the main orifice. See Engineering Section for further details. Standard and Optional Features: Solenoid valves are supplied, as listed, with either Red-Hat II molded epoxy solenoids or Red-Hat solenoids with metal enclosures. Red-Hat II valves are identified by the letter G or H in their catalog numbers; e.g., 8030G16. Many optional features may be added to your valves; e.g., high-temperature Class H molded coils, manual operators, and metering devices. 2 Way/2 Position Valves Flow Diagrams Normally Closed Valve De-Energized Normally Closed Valve Energized Normally Open Valve De-Energized Normally Open Valve Energized

3 qwer Direct Acting Low Pressure Solenoid Valves Brass or Stainless Steel Bodies 3/8" to 3/" NPT NC NO 2/2 SERIES 8030 Features Operate at low pressures: no minimum required; up to 15 psi maximum differential. Normally Closed or Normally Open operation. Widely used for dispensing, collating, gas shutoff, vacuum holding, and tank draining applications. Normally Open valve well suited for venting systems. Construction Valve Parts in Contact with Fluids Body Brass 30 Stainless Steel Seals and Disc Core Tube Core and Plugnut Core Spring NBR 305 Stainless Steel 30F Stainless Steel 302 Stainless Steel Shading Coil Copper Silver Stem PA (Normally Open) % ^ # ) Electrical Watt Rating and Power Consumption Solenoid Enclosures Spare Coil Part Number Standard Coil and AC General Purpose Explosionproof Class of Insulation DC Watts VA Watts Holding VA Inrush AC DC AC DC F F F F F Standard Voltages: 2, 120, 20, 80 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz), 6, 12, 2, 120, 20 volts DC. Must be specified when ordering. Other voltages available when required. Standard: Watertight, Types 1, 2, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalog number.) Nominal Ambient Temperature Ranges: AC: 32 F to 125 F (0 C to 52 C) DC: 32 F to 10 F (0 C to 0 C) Approvals: CSA certified. UL listed, as indicated. FM approved (Normally Closed only except 8030G17 and 8030G67). Meets applicable CE directives. 1

4 8030 Specifications (English units) Operating Pressure Differential (psi) Max. AC Max. DC Pipe (ins.) Orifice (ins.) Cv Flow Factor Min. Air- Inert Gas Water Air- Inert Gas Water AC DC NORMALLY CLOSED (Closed when de-energized) Max. Fluid Temp. F Brass Body Stainless Steel Body Catalog Number Ref. No. UL 2 Listing Catalog Number Ref. No. UL 2 Listing Insulation 1 3/8 3/ G G /F 10.6/F 3/8 3/ G G /F 11.6/F 1/2 7/ G G /F - 1/2 7/ G G /F - 3/ 3/ G /F 11.6/F 3/ 3/ G /F - 3/ 5/ G /F - NORMALLY OPEN (Open when de-energized) 3/8 3/ G /F - 1/2 7/ G /F - 1/2 3/ G /F - 3/ 3/ G /F - Notes: 1 On all 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts. 2 = Safety Shutoff Valve; = General Purpose Valve. Refer to Engineering Section (Approvals) for details. AC DC Specifications (Metric units) Operating Pressure Differential (bar) Max. AC Max. DC Air- Air- Inert Inert Gas Water Gas Water Max. Fluid Temp. C Brass Body Stainless Steel Body Insulation 1 Pipe (ins.) Orifice (mm) Kv Flow Factor (m3/h) Min. AC DC Catalog Number Ref. No. UL 2 Listing Catalog Number Ref. No. UL 2 Listing AC DC NORMALLY CLOSED (Closed when de-energized) 3/ G G /F 10.6/F 3/ G G /F 11.6/F 1/ G G /F - 1/ G G /F - 3/ G /F 11.6/F 3/ G /F - 3/ G /F - NORMALLY OPEN (Open when de-energized) 3/ G /F - 1/ G /F - 1/ G /F - 3/ G /F - Notes: 1 On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts. 2 = Safety Shutoff Valve; = General Purpose Valve. Refer to Engineering Section (Approvals) for details. 2

5 8030 Dimensions: inches (mm) Ref. No. H K L P W 1 ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm IMPORTANT: Valves may be mounted in any position, except for 8030G3 DC. Refs. 1, 2, 3 Refs. 7, 8 3

6 8030 Dimensions: inches (mm) Refs. 9, 10 Refs. 11, 12, 13

7 qwer Direct Acting or Piloted Aluminum Body Solenoid Valves 3/8" to 3" NPT NC NO NC NO 2/2 SERIES Features Lightweight, low-cost valves for air service. Ideal for low pressure applications. Provides high flow, Cv up to 138 (Kv 118). Air and vacuum service. Construction Valve Parts in Contact with Fluids Body Aluminum Seals, Diaphragms, Disc NBR Disc-Holder PA (10.1 and 11.6 watt Normally Open only) Core Guide CA Core Tube 305 Stainless Steel Rider Rings PTFE Core and Plugnut 30F Stainless Steel Springs 302 Stainless Steel Shading Coil Copper % ^ # ) Electrical Watt Rating and Power Consumption Spare Coil Part No. Standard AC Coil and Class of DC VA VA General Purpose Explosionproof Insulation Watts Watts Holding Inrush AC DC AC DC F F B F F Standard Voltages: 2, 120, 20, 80 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz), 6, 12, 2, 120, 20 volts DC. Must be specified when ordering. Other voltages available when required. Solenoid Enclosures Standard: Red-Hat II - Watertight, Types 1, 2, 3, 3S,, and X; Red-Hat - Type I. Optional: Red-Hat II - Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9; Red-Hat - Explosionproof and Raintight, Types 3, 7, and 9. (Except EF8215A0 and EF8215A90, which are suitable for Types 3 and 7 (C and D) only and have a T2B temperature rating code.) To order, add prefix EF to catalog number. Nominal Ambient Temperature Ranges: Red-Hat II/ Red-Hat AC: 32 F to 125 F (0 C to 52 C) Red-Hat II DC: 32 F to 10 F (0 C to 0 C) Red-Hat DC: 32 F to 77 F (0 C to 25 C) (10 F/0 C occasionally) Approvals: 8215 CSA certified. UL listed, as indicated. FM approved (Normally Closed only, except Catalog Numbers 8215A90 and 8215A0). Red-Hat II meets applicable CE directives. 5

8 Specifications (English units) Pipe (ins.) Orifice (ins.) Cv Flow Factor Operating Pressure Differential (psi) Min. Max. AC Air-Fuel Gas Max. DC Max. Fluid Temp. F Air-Fuel Gas AC DC Catalog Number Aluminum Body Ref. No Insulation ➁ UL ➄ Listing AC DC NORMALLY CLOSED (Closed when de-energized) 1/8 5/ H /F - 1/ 5/ H /F - 3/8 5/ H /F - 3/8 3/ G /F 11.6/F 3/8 3/ G1 ➀ 1 6.1/F 11.6/F 1/2 3/ G22 13A 10.1/F - 1/2 3/ G /F 11.6/F 1/2 3/ G2 ➀ 1 6.1/F 11.6/F 3/ 3/ G23 13B 10.1/F - 3/ 3/ G /F 11.6/F 3/ 3/ G3 ➀ 3 6.1/F 11.6/F 1 1 5/ B50 ➂ 6 15./F 1.9/B 1 1/ 1 5/ B60 ➂ 6 15./F 1.9/B 1 1/2 1 5/ B70 ➂ 6 15./F 1.9/B 2 2 3/ B80 ➂ 7 15./F 1.9/B 2 1/ A /F A /F - NORMALLY OPEN (Open when de-energized) Notes: 3/8 3/ G /F 11.6/F 1/2 3/ G /F 11.6/F 3/ 3/ G /F 11.6/F 1 1 5/ C /F 1.9/B 1 1/ 1 5/ C /F 1.9/B 1 1/2 1 5/ C /F 1.9/B 2 2 3/ C /F 1.9/B 2 1/ B93 ➃ /F - ➀ Do not use for Fuel Gas. ➁ On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts. ➂ FM Approved Process Control Valves. See Engineering Section (Approvals) for details. ➃ Type 1 enclosure only. ➄ = Safety Shutoff Valve; = General Purpose Valve. Refer to Engineering Section (Approvals) for details. 6

9 Specifications (Metric units) Pipe (ins.) Orifice (mm) Kv Flow Factor (m3/h) Operating Pressure Differential (bar) Min. Max. AC Air-Fuel Gas Max. DC Max. Fluid Temp. C Air-Fuel Gas AC DC Catalog Number Aluminum Body Ref. No Insulation ➁ UL ➄ Listing AC DC NORMALLY CLOSED (Closed when de-energized) 1/ H /F - 1/ H /F - 3/ H /F - 3/ G /F 11.6/F 3/ G1 ➀ 1 6.1/F 11.6/F 1/ G22 13A 10.1/F - 1/ G /F 11.6/F 1/ G2 ➀ 1 6.1/F 11.6/F 3/ G23 13B 10.1/F - 3/ G /F 11.6/F 3/ G3 ➀ 3 6.1/F 11.6/F B50 ➂ 6 15./F 1.9/B 1 1/ B60 ➂ 6 15./F 1.9/B 1 1/ B70 ➂ 6 15./F 1.9/B B80 ➂ 7 15./F 1.9/B 2 1/ A /F A /F - NORMALLY OPEN (Open when de-energized) 3/ G /F 11.6/F 1/ G /F 11.6/F 3/ G /F 11.6/F C /F 1.9/B 1 1/ C /F 1.9/B 1 1/ C /F 1.9/B C /F 1.9/B 2 1/ B93 ➃ /F - Notes: ➀ Do not use for Fuel Gas. ➁ On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts. ➂ FM Approved Process Control Valves. See Engineering Section (Approvals) for details. ➃ Type 1 enclosure only. ➄ = Safety Shutoff Valve; = General Purpose Valve. Refer to Engineering Section (Approvals) for details. 7

10 Dimensions: inches (mm) Ref. No. H K L P W 1 ins mm ins mm ins mm ins mm ➀ ins. 6.8 x mm 17 x ➀ ins. 7.7 x mm 190 x ➀ ins x mm 260 x ins mm ins mm ins mm ins. 6.8 x mm 17 x ins. 6.8 x mm 17 x A ins mm B ins mm ➁ ins. 7. x mm 189 x ➁ ins x mm 260 x IMPORTANT: Valves may be mounted in any position except all DC constructions and those marked ➀, which must be mounted with the solenoid vertical and upright. Constructions marked ➁ must be mounted with the solenoid vertical and upright or horizontal only. Refs. 1-, 9, 10, 13a, 13b Refs. 6, 7, 8, Refs. 11 8

11 qwer Pilot Operated General Service Solenoid Valves Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT NC NO 2/2 SERIES 8210 Features Wide range of pressure ratings, sizes, and resilient materials provide long service life and low internal leakage. High Flow Valves for liquid, corrosive, and air/inert gas service. Industrial applications include: - Car wash - Laundry equipment - Air compressors - Industrial water control - Pumps Construction Valve Parts in Contact with Fluids % ) Body Brass 30 Stainless Steel Seals and Discs Disc-Holder Core Tube Core and Plugnut Springs NBR or PTFE PA 305 Stainless Steel 30F Stainless Steel 302 Stainless Steel Shading Coil Copper Silver Electrical Watt Rating and Power Consumption Spare Coil Part Number Standard Coil and AC General Purpose Explosionproof Class of Insulation DC Watts Watts VA Holding VA Inrush AC DC AC DC F F F F F F H F Standard Voltages: 2, 120, 20, 80 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz). 6, 12, 2, 120, 20 volts DC. Must be specified when ordering. Other voltages available when required. Solenoid Enclosures Standard: Red-Hat II - Watertight, Types 1, 2, 3, 3S,, and X; Red-Hat - Type I. Optional: Red-Hat II - Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9; Red-Hat - Explosionproof and Watertight, Types 3,, X, 7, and 9. (To order, add prefix EF to catalog number, except Catalog Numbers 8210B57, 8210B58, and 8210B59. Valves not available with Explosionproof enclosures.) Nominal Ambient Temperature Ranges: Red-Hat II/ Red-Hat AC: 32 F to 125 F (0 C to 52 C) Red-Hat II DC: 32 F to 10 F (0 C to 0 C) Red-Hat DC: 32 F to 77 F (0 C to 25 C) (10 F/0 C occasionally) Approvals: CSA certified. Red-Hat II meets applicable CE directives. 9

12 8210 Specifications (English units) Operating Pressure Differential (psi) Max. AC Max. DC Pipe Orifice Cv Flow Air- Inert Light 300 Air- Inert Light 300 (ins.) (ins.) Factor Min. Gas Water SSU Gas Water NORMALLY CLOSED (Closed when de-energized), NBR or PTFE ➁ Seating 10 Max. Fluid Temp. F Brass Body Stainless Steel Body Catalog Ref. UL ➄ Catalog Ref. Number No. ➃ Listing Number No. ➃ SSU AC DC Insulation ➆ UL ➄ Listing AC DC 3/8 3/8 1.5 ➀ G73 ➂ 1P 8210G36 ➂ 1P 6.1/F 11.6/F 3/8 5/ G93 5D /F 11.6/F 3/8 5/ G1 6D /F 11.6/F 3/8 5/ G6 5D /F - 1/2 7/ ➀ G15 ➂ 2P 8210G37 ➂ 2P 6.1/F 11.6/F 1/2 5/ G9 5D /F 11.6/F 1/2 5/ G87 7D 17.1/F 11.6/F 1/2 5/ G2 6D /F 11.6/F 1/2 5/ G7 5D /F - 1/2 5/ G227 5D /F 0.6/H 3/ 5/ G88 7D 17.1/F 11.6/F 3/ 3/ G9 9D /F 11.6/F 3/ 3/ G95 8D /F 11.6/F 3/ 3/ G3 11D /F 11.6/F 3/ 3/ B26 ➁ 10P /H 3/ 3/ G26 ➁ 0P F B5 31D D89 15D /H G5 1D 8210G89 5D 16.1/F G 12D /F 11.6/F G27 2P /F G78 3P /F - 1 1/ 1 1/ B55 32D /H 1 1/ 1 1/ G55 3D /F - 1 1/ 1 1/ G8 16D /F 11.6/F 1 1/2 1 1/ B56 33D /H 1 1/2 1 1/ G56 D /F - 1 1/2 1 1/ G22 18D /F 11.6/F 2 1 3/ G100 20P /F 11.6/F 2 1/2 1 3/ G101 21P /F 11.6/F NORMALLY OPEN (Open when de-energized), NBR Seating (PA Disc-Holder, except as noted) 3/8 5/ G33 23D /F 11.6/F 3/8 5/ G11 ➇ ➈ 39D /F 11.6/F 1/2 5/ G3 23D /F 11.6/F 1/2 5/ G30 37D 10.1/F 11.6/F 1/2 5/ G12 ➇ ➈ 39D /F 11.6/F 3/ 3/ G35 25D /F 11.6/F 3/ 5/ G38 38D 10.1/F 11.6/F 3/ 3/ C13 2D /F 3/ 3/ G13 6D /F B57 ➅ ➉ 3D /F D1 26D /F G1 7D /F - 1 1/ 1 1/ B58 ➅ ➉ 35D /F - 1 1/ 1 1/ D18 28D /F 1 1/ 1 1/ G18 8D /F - 1 1/2 1 1/ B59 ➅ ➉ 36D /F - 1 1/2 1 1/ D32 29D /F 1 1/2 1 1/ G32 9D /F / P /F 2 1 3/ G103 50P /F - 2 1/2 1 3/ P /F 2 1/2 1 3/ G10 51P /F - Notes: ➀ 5 psi on Air; 1 psi on Water. ➁ Valve provided with PTFE main disc. ➂ Valve includes UItem (G.E. trademark) piston. ➃ Letter "D" denotes diaphragm construction; "P" denotes piston construction. ➄ Safety Shutoff Valve; General Purpose Valve. Refer to Engineering Section (Approvals) for details. ➅ Valves not available with Explosionproof enclosures. ➆ On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts. ➇ AC construction also has PA seating. ➈ No disc-holder. ➉ Stainless Steel disc-holder. Must have solenoid mounted vertical and upright.

13 8210 Specifications (Metric units) Operating Pressure Differential (bar) Max. AC Max. DC Pipe Orifice Kv Flow Factor Air- Inert Light 300 Air- Inert Light 300 (ins.) (mm) (m3/h) Min. Gas Water SSU Gas Water NORMALLY CLOSED (Closed when de-energized), NBR or PTFE ➁ Seating Max.Fluid Temp. C Brass Body Stainless Steel Body Ref. UL ➄ Catalog Ref. No. ➃ Listing Number No. ➃ SSU AC DC Catalog Number Insulation ➆ UL ➄ Listing AC DC 3/ ➀ G73 ➂ 1P 8210G36 ➂ 1P 6.1/F 11.6/F 3/ G93 5D /F 11.6/F 3/ G1 6D /F 11.6/F 3/ G6 5D /F - 1/ ➀ G15 ➂ 2P 8210G37 ➂ 2P 6.1/F 11.6/F 1/ G9 5D /F 11.6/F 1/ G87 7D 17.1/F 11.6/F 1/ G2 6D /F 11.6/F 1/ G7 5D /F - 1/ G227 5D /F 0.6F 3/ G88 7D 17.1/F 11.6/F 3/ G9 9D /F 11.6/F 3/ G95 8D /F 11.6/F 3/ G3 11D /F 11.6/F 3/ B26 ➁ 10P /H 3/ G26 ➁ 0P F B5 31D D89 15D /H G5 1D 8210G89 5D 16.1/F G 12D /F 11.6/F G27 2P /F G78 3P /F - 1 1/ B55 32D /H 1 1/ G55 3D /F - 1 1/ G8 16D /F 11.6/F 1 1/ B56 33D /H 1 1/ G56 D /F - 1 1/ G22 18D /F 11.6/F G100 20P /F 11.6/F 2 1/ G101 21P /F 11.6/F NORMALLY OPEN (Open when de-energized), NBR Seating (PA Disc-Holder, except as noted) 3/ G33 23D /F 11.6/F 3/ G11 ➇ ➈ 39D /F 11.6/F 1/ G3 23D /F 11.6/F 1/ G30 37D 10.1/F 11.6/F 1/ G12 ➇ ➈ 39D /F 11.6/F 3/ G35 25D /F 11.6/F 3/ G38 38D 10.1/F 11.6/F 3/ C13 2D /F 3/ G13 6D /F B57 ➅ ➉ 3D /F D1 26D /F G1 7D /F - 1 1/ B58 ➅ ➉ 35D /F - 1 1/ D18 28D /F 1 1/ G18 8D /F - 1 1/ B59 ➅ ➉ 36D /F - 1 1/ D32 29D /F 1 1/ G32 9D /F P /F G103 50P /F - 2 1/ P /F 2 1/ G10 51P /F - Notes: ➀ 0.3 bar on Air; 0.0 bar on Water. ➁ Valve provided with PTFE main disc. ➂ Valve includes UItem (G.E. trademark) piston. ➃ Letter "D" denotes diaphragm construction; "P" denotes piston construction. ➄ Safety Shutoff Valve; General Purpose Valve. ➅ Valves not available with Explosionproof enclosures. ➆ On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts. ➇ AC construction also has PA seating. ➈ No disc-holder. ➉ Stainless Steel disc-holder. Refer to Engineering Section (Approvals) for details. Must have solenoid mounted vertical and upright. 11

14 8210 Dimensions: inches (mm) Ref. No. H K L P W 1* ins mm * ins mm ins mm ins mm * ins mm ins mm ins mm * ins mm *➀ ins X mm 133 X * ins mm * ins. 5.3 X mm 136 X * ins mm * ins mm ins mm ins X mm 129 X ins mm ins X mm 166 X ins X mm 209 X ins X mm 166 X ins X mm 179 X ➀ Valves must be mounted with solenoid vertical and upright. * DC dimensions slightly larger. Refs. 1, 2 Ref. 3 W P K L Refs. 5-9, 11, 20, 21, 23, 25, 37,38 H 12

15 8210 Dimensions: inches (mm) 30 ins X mm 209 X ins X mm 133 X ins X mm 15 X ins X mm 15 X ins X mm 176 X ins. 7.3 X mm 186 X ins X mm 1.95 X ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm IMPORTANT: Valves may be mounted in any position, except as noted in specifications table. Refs. 10, 15, 2, Refs. 12, 16, 18 P K H W L Note: Valve must be mounted with solenoid vertical and upright. 13

16 8210 Dimensions: inches (mm) Refs. 39 Refs

17 qwer Pilot Operated Slow Closing Solenoid Valves Brass Body 3/8" to 2 1/2" NPT NC NO 2/2 SERIES 8221 Features Pilot Operated, Normally Open or Normally Closed. Snubber slows disc closing speed to protect system against water hammer damage more effectively than other techniques. Pressure spike due to water hammer reduced to a point eliminating the need for suppressors or other controls in most water systems. Fluid Controls Institute Inc. evaluations have classified these valves: Pipe s FCI-82-1 Class 3 / 8, 1 / 2, 3 / CC 1, 1 1 /, 1 1 / 2, 2, 2 1 / 2 BB % ^ ) Construction Valve Parts in Contact with Fluids Body Disc Seals Core Tube Core and Plugnut Springs Piston Shading Coil Brass NBR PTFE & NBR 305 Stainless Steel 30F Stainless Steel 302 Stainless Steel Stainless Steel or Brass Copper Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Solenoid Enclosures Spare Coil Part No. AC General Purpose Explosionproof DC Watts Watts VA Holding VA Inrush AC DC AC DC F F F Standard Voltages: 2, 120, 20, 80 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz). 6, 12, 2, 120, 20 volts DC. Must be specified when ordering. Other voltages are available when required. Standard: Red-Hat II - Watertight, Types 1, 2, 3, 3S,, and X; Red-Hat - Type I. Optional: Red-Hat II - Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9; Red-Hat - Explosionproof and Raintight, Types 3, 7, and 9. (To order, add prefix EF to catalog number.) Nominal Ambient Temperature Ranges: Red-Hat II/ Red-Hat AC: 32 F to 125 F (0 C to 52 C) Red-Hat II DC: 32 F to 10 F (0 C to 0 C) Red-Hat DC: 32 F to 77 F (0 C to 25 C) (10 F/0 C occasionally) Approvals: CSA certified. UL listed, General Purpose Valves. Red-Hat II meets applicable CE directives. 15

18 8221 Specifications (English units) Operating Pressure Differential (psi) Max. AC Max. DC Maximum Fluid Temp. F Brass Body Insulation ➂ Pipe (ins.) Orifice (ins.) Cv Flow Factor Min. ➀ Water ➁ Water ➁ AC DC Catalog Number Ref. No. AC DC NORMALLY CLOSED (Closed when de-energized) 3/8 9/ G /F 11.6/F 1/2 9/ G /F 11.6/F 3/ 3/ G /F 11.6/F G /F 11.6/F 1 1/ 1 1/ G /F 11.6/F 1 1/2 1 1/ G /F 11.6/F 2 1 3/ G /F 22.6/F 2 1/2 1 3/ G /F 22.6/F NORMALLY OPEN (Open when de-energized) 3/8 9/ /F 3/8 9/ G /F - 1/2 9/ /F 1/2 9/ G /F - 3/ 3/ /F 3/ 3/ G /F /F G /F - 1 1/ 1 1/ /F 1 1/ 1 1/ G /F - 1 1/2 1 1/ /F 1 1/2 1 1/ G /F / /F 2 1 3/ G /F - 2 1/2 1 3/ /F 2 1/2 1 3/ G /F Notes: ➀ Valves require a 5 psi Minimum Pressure Differential to open. Once open, they remain open with 3 psi differential pressure. ➁ Refer to Steam/Hot Water Valve Series for Hot Water constructions. ➂ On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts. 16

19 8221 Specifications (Metric units) Operating Pressure Differential (bar) Max. AC Max. DC Maximum Fluid Temp. C Brass Body Insulation ➂ Pipe (ins.) Orifice (mm) Kv Flow Factor (m3/h) Min. ➀ Water ➁ Water ➁ AC DC Catalog Number Ref. No. AC DC NORMALLY CLOSED (Closed when de-energized) 3/ G /F 11.6/F 1/ G /F 11.6/F 3/ G /F 11.6/F G /F 11.6/F 1 1/ G /F 11.6/F 1 1/ G /F 11.6/F G /F 22.6/F 2 1/ G /F 22.6/F NORMALLY OPEN (Open when de-energized) 3/ /F 3/ G /F - 1/ /F 1/ G /F - 3/ /F 3/ G /F /F G /F - 1 1/ /F 1 1/ G /F - 1 1/ /F 1 1/ G /F /F G /F - 2 1/ /F 2 1/ G /F - Notes: ➀ Valves require a 0.3 bar Minimum Pressure Differential to open. Once open, they remain open with 0.2 bar differential pressure. ➁ Refer to Steam/Hot Water Valve Series for Hot Water constructions. ➂ On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts. 17

20 8221 Dimensions: inches (mm) Ref. No. H K L P W 1 ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins X mm 133 X ins. 5.1 X mm 137 X ins X mm 166 X ins. 6.7 X mm 16 X ins X mm 179 X ins X mm 209 X ins X mm 209 X IMPORTANT: Valves may be mounted in any position. Refs. 1, 2 Refs. 3, Refs. 5, 6, 7, 11, 12 Refs. 15, 16 Refs. 8, 9, 10, 13, 1 Refs

21 qwer Pilot Operated High Pressure Solenoid Valves Brass or Stainless Steel Bodies 1/" to 3/" NPT NC 2/2 SERIES 8223 Features Rugged piston construction built to withstand pressure ratings of 50 to 1500 psi. Angle body design for high flows. Ideal for high pressure water applications, such as car washes. Mountable in any position. % ) Construction Valve Parts in Contact with Fluids Body Brass 300 Stainless Steel Seals and Disc NBR, PA, PTFE PTFE, NBR Core Tube Core and Plugnut 305 Stainless Steel 30F Stainless Steel Core Spring 302 Stainless Steel Shading Coil Copper Silver Stem PA (Normally Open) Electrical Watt Rating and Power Consumption Spare Coil Part Number Standard Coil and Class of Insulation DC Watts Watts Solenoid Enclosures AC General Purpose Explosionproof VA Holding VA Inrush AC DC AC DC F F Standard Voltages: 2, 120, 20, 80 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz). 6, 12, 2, 120, 20 volts DC. Must be specified when ordering. Other voltages available when required. Standard: Watertight, Types 1, 2, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalog number.) Nominal Ambient Temperature Ranges: AC: 32 F to 125 F (0 C to 52 C) DC: 32 F to 10 F (0 C to 0 C) Approvals: Brass Version CSA certified. Meets applicable CE directives. 19

22 8223 Specifications (English units) Operating Pressure Differential (psi) Max. AC Max. DC Maximum Fluid Temp. F Brass Body Stainless Steel Body Insulation Pipe (ins.) Orifice (ins.) Cv Flow Factor Min. Air- Inert Gas Water Light 300 SSU Air- Inert Gas Water Light 300 SSU AC DC Catalog Number Ref. No. Catalog Number Ref. No. AC DC NORMALLY CLOSED (Closed when de-energized) 1/ 5/ G /F - 1/ 5/ G /F 22.6/F 3/8 5/ G /F 22.6/F 3/8 5/ G /F 22.6/F 1/2 3/ G G /F 22.6/F 3/ 3/ G G /F 22.6/F Specifications (Metric units) Operating Pressure Differential (bar) Max. AC Max. DC Maximum Fluid Temp. C Brass Body Stainless Steel Body Insulation Pipe Orifice Kv Flow Air- Light Oil Air- Light Oil Factor Catalog Catalog (ins.) (mm) (m3/h) Min. Gas Water SSU Gas Water SSU AC DC Number Ref. No. Number Ref. No. AC DC NORMALLY CLOSED (Closed when de-energized) 1/ G /F - 1/ G /F 22.6/F 3/ G /F 22.6/F 3/ G /F 22.6/F 1/ G G /F 22.6/F 3/ G G /F 22.6/F Dimensions: inches (mm) H K L P W Ref. No. 1 ins mm ins mm ins mm ins mm ins mm Refs

23 Direct Acting Sub-Miniature Solenoid Valves Brass, Stainless Steel or Aluminum Bodies 1/8" NPT NC 2/2 SERIES Features Economical, Normally Closed valves for a wide range of OEM applications. Convertable from AC to DC by changing the molded epoxy open frame coil. Individual valves handle mildly aggressive fluids. Group mounted valves (max. 10 valves) have aluminum bodies and built-in manual operators for air service. Mountable in any position. % ^ ) Construction Valve Parts in Contact with Fluids Body Individual Valves Brass Stainless Steel Group Mounted Aluminum Seals and Discs NBR or FKM Core and Plugnut 30F Stainless Steel Core Springs 302 Stainless Steel Shading Coil Copper Electrical Standard Coil and Class of Insulation Solenoid DC Watts Watt Rating and Power Consumption Watts Standard: Molded epoxy open frame solenoid can be converted from AC to DC by simply changing the coil. Optional: 3x DIN 62 coil; 1/2 Threaded Conduit Hub. AC Spare Coil Part Number VA Holding VA Inrush AC DC F Standard Voltages: 2, 120, 20, 80 volts AC, 60 Hz (or 110, 220 volts AC 50 Hz). 6, 12, 2, 120, 20 volts DC. Must be specified when ordering. Other voltages available when required. Nominal Ambient Temperature Ranges: AC: 32 F to 135 F (0 C to 57 C) DC: 32 F to 77 F (0 C to 25 C) Approvals: CSA certified. UL Recognized Component. Meets applicable CE directives. 21

24 Specifications (English units) Operating Pressure Differential (psi) Max. Open Frame Solenoid Pipe Orifice Max. AC Max. DC Fluid Brass Body Stainless Steel Body Temp. F Insulation Cv Flow Air-Inert Light Air-Inert Light (ins.) (ins.) Factor Gas Water 300 SSU Gas Water 300 SSU AC DC Catalog Number Catalog Number AC DC NORMALLY CLOSED (Closed when de-energized), FKM Disc 1/8 3/ U8225B1V U8225B5V 6.3/F 6.9/F 1/8 1/ U8225B2V U8225B6V 6.3/F 6.9/F 1/8 3/ U8225B3V U8225B7V 6.3/F 6.9/F 1/8 1/ U8225BV U8225B8V 6.3/F 6.9/F Operating Pressure Differential (psi) Max. Open Frame Solenoid Pipe Orifice Max. AC Max. DC Fluid Operator Only Sub-Base Construction Cv Flow Temp. F Insulation (ins.) (ins.) Factor Air-Inert Gas Air-Inert Gas AC DC Catalog Number Catalog Number AC DC GROUP MOUNTING -NORMALLY CLOSED (Closed when de-energized), Aluminum Body, NBR Disc 1/8 3/ U8280B1 U8280B2 6.3/F 6.9/F Specifications (Metric units) Operating Pressure Differential (bar) Max. Fluid Open Frame Solenoid Pipe Orifice Kv Flow Max. AC Max DC Temp. C Brass Body Stainless Steel Body Insulation (ins.) (mm) Factor (m3/h) Air-Inert Gas Water Light 300 SSU Air-Inert Gas Water Light 300 SSU AC DC Catalog Number Catalog Number AC DC NORMALLY CLOSED (Closed when de-energized), FKM Disc 1/ U8225B1V U8225B5V 6.3/F 6.9/F 1/ U8225B2V U8225B6V 6.3/F 6.9/F 1/ U8225B3V U8225B7V 6.3/F 6.9/F 1/ U8225BV U8225B8V 6.3/F 6.9/F Max. Operating Pressure Differential (bar) Open Frame Solenoid Fluid Pipe Orifice Kv Flow Max. AC Max. DC Temp C Operator Only Sub-Base Construction Insulation Factor (ins.) (mm) (m3/h) Air-Inert Gas Air-Inert Gas AC DC Catalog Number Catalog Number AC DC GROUP MOUNTING - NORMALLY CLOSED (Closed when de-energized), Aluminum Body, NBR Disc 1/ U8280B1 U8280B2 6.3/F 6.9/F Dimensions: inches (mm) 8225 Series 8280 Series 22

25 qwer Direct Acting Plastic Body Solenoid Valves Hose Bib, Compression Connection or 1/" Male Flare NC 2/2 SERIES 8260 Features Corrosion resistent plastic bodies. Available with compression fitting ends for metal or plastic tube to save installation cost. Mountable in any position. Dispensing vending construction NSF listed. % & Construction Body Seals and Disc Core Tube Core and Plugnut Springs Shading Coil Valve Parts in Contact with Fluids CA, PA, PP NBR 305 Stainless Steel 30F Stainless Steel 302 Stainless Steel Copper ) Electrical Watt Rating and Power Consumption AC Spare Coil Part Number General Purpose Standard Coil and Class of Insulation DC Watts Watts VA Holding VA Inrush AC DC B F Standard Voltages: 2, 120, 20, 80 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz). 6, 12, 2, 120, 20 volts DC. Must be specified when ordering. Other voltages available when required. Nominal Ambient Temperature Range: AC: 32 F to 125 F (0 C to 52 C) DC: 32 F to 10 F (0 C to 0 C) Solenoid Enclosures Standard: Watertight, Types 1, 2, 3, 3S,, and X. Optional: Open Frame Solenoid, Junction Box enclosures. Approvals: CSA certified. UL Recognized Component. Meets applicable CE directives. 23

26 8260 Specifications (English units) Orifice (ins.) Cv Flow Factor Specifications (Metric units) Operating Pressure Differential (psi) Max. AC Max. DC Max. Fluid Temp. F Plastic Body Insulation ➁ Pipe Connections Air-Inert Gas Water Air-Inert Gas Water AC DC Catalog Number Ref. No. AC DC GENERAL SERVICE CONSTRUCTION - CA Body, Watertight enclosure with leads 1/" Male Flare 9/ G /F 10.6/F Bib for 1/" I.D. Tube 9/ G /F 10.6/F 1/" O.D. ➀ Compression 9/ G /F 10.6/F GENERAL SERVICE CONSTRUCTION - PP Body, Open Frame Solenoid and Spade Terminal Coils 1/" O.D. ➀ Compression 1/ USM /B 6./B 3/ USM /B 6./B 1/ USM /B 6./B 5/ USM /B 6./B DISPENSING VENDING CONSTRUCTION - NSF Listed - PP Body, Open Frame Solenoid and Spade Terminal Coils 1/" O.D. ➀ Compression 1/ USM /B 6./B 3/ USM /B 6./B 1/ USM /B 6./B 5/ USM /B 6./B DISPENSING VENDING CONSTRUCTION - NSF Listed - PA Body, Open Frame Solenoid and Spade Terminal Coils 3/8" O.D. ➀ Compression 5/ USM /B - PA Body, Open Frame Solenoid and Spade Terminal Coils 3/8" O.D. ➀ Compression 5/ USM /B - Notes: ➀ Fittings not supplied with valve. To order, refer to List Price Schedule. Kit No plastic tubing, and Kit No metal tubing. ➁ On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts. Pipe Connections Orifice (mm) Kv Flow Factor (m3/h) Operating Pressure Differential (bar) Max. AC Max. DC Max. Fluid Temp. C Air-Inert Gas Water Air-Inert Gas Water AC DC GENERAL SERVICE CONSTRUCTION - CA Body, Watertight enclosure with leads Plastic Body Catalog Number Insulation ➁ Ref. No. AC DC 1/" Male Flare G /F 10.6/F Bib for 1/" I.D. Tube G /F 10.6/F 1/" O.D. ➀ Compression G /F 10.6/F GENERAL SERVICE CONSTRUCTION - PP Body, Open Frame Solenoid and Spade Terminal Coils "1/" O.D. ➀ Compression USM /B 6./B USM /B 6./B USM /B 6./B USM /B 6./B DISPENSING VENDING CONSTRUCTION - NSF Listed - PP Body, Open Frame Solenoid and Spade Terminal Coils 1/" O.D. ➀ Compression USM /B 6./B USM /B 6./B USM /B 6./B USM /B 6./B DISPENSING VENDING CONSTRUCTION - NSF Listed - PA Body, Open Frame Solenoid and Spade Terminal Coils 3/8" O.D. ➀ Compression USM /B - PA Body, Open Frame Solenoid and Spade Terminal Coils 3/8" O.D. ➀ Compression USM /B - Notes: ➀ Fittings not supplied with valve. To order, refer to List Price Schedule. Kit No plastic tubing, and Kit No metal tubing. ➁ On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts. 2

27 8260 Dimensions: inches (mm) Refs. 1 Refs. 2 Refs. 3 25

28 8260 Dimensions: inches (mm) Refs. 1.31(3.33) 0.8 (20.6) 0.3 (9.5) 1 WIDE x 1 2 THICK TERMINALS 0.98 (25.0) 1.97 (50.0) 0.33 (8.3).13 (3.6) DIA. HOLES x 0.31 (7.9) DEEP, (2) MOUNTING HOLES UNF-2A THREAD (BOTH ENDS) IC.666 (16.9) 1.5 (38.1) 1.88 (7.6) 1.28 (32.5) (NOTE 1).333 (8.).200 (5.0).75 (12.1).170 (.3) DIA. HOLE (2 PLACES) FLOW 2 (50.8) 1 (25.) A. C. CONSTRUCTION SHOWN 0.1 (10.3) (REF) 1 0. (11.1) HEXAGON (BOTH ENDS) 1 16 ORIFICE SIZE SHOWN 0.03 (0.79) 1.15 (29.) 0.9 (22.2) Refs (3.33) 0.8 (20.6) 0.3 (9.5) (6) (0.8) 1 WIDE x 1 2 THICK TERMINALS 0.98 (25.0) 1.97 (50.0) 0.33 (8.3).13 (3.6) DIA. HOLES x 0.31 (7.9) DEEP, (2) MOUNTING HOLES UNF-2A THREAD (BOTH ENDS) 1.5 (38.1) 1.88 (7.6) 1.28 (32.5) (NOTE 1) IC.666 (16.9).333 (8.).200 (5.0).75 (12.1).170 (.3) DIA. HOLE (2 PLACES) FLOW 2 (50.8) 1 (25.) A. C. CONSTRUCTION SHOWN 0.1 (10.3) (REF) 1 0. (11.1) HEXAGON (BOTH ENDS) 1 16 ORIFICE SIZE SHOWN 0.03 (0.79) 1.15 (29.) 0.9 (22.2) 1.31 (33.3) (20.6) (9.53) (6) (0.8) 1 WIDE x 1 2 THICK TERMINALS Refs. 6 (8.3) (27.8) 0. (11.1) (15.1) (7.5) (76) (17.5) BODY SHOWN ONLY (8.7) (Ø 8.7) FLOW 2.3 (62) 1.21 (30.7) (16) UN-2A THREAD (BOTH ENDS) 1 (25.) 2 (51) 2 MOUNTING HOLES 11/32 DEEP, FOR NO. 10 THREADS CUTTING SCREW 26

29 qwer Direct Acting General Service Solenoid Valves Brass or Stainless Steel Bodies 1/8" to 3/8" NPT NC NO 2/2 SERIES Features Reliable, proven design with high flows. Small poppet valves for tight shutoff. Wide range of elastomers for specialty service. Mountable in any position. Brass body construction for general atmospheres; Stainless Steel for corrosive atmospheres. Construction Valve Parts in Contact with Fluids Body Brass 303/30 Stainless Steel Seals and Discs NBR or Cast UR % ^ # ) Core Tube Core and Plugnut Springs 305 Stainless Steel 30F Stainless Steel 302 Stainless Steel Shading Coil Copper Silver Stem PA (Normally Open) Note: All 1/8" NPT Normally Open valves contain CA. All 1/" NPT Normally Open valves contain PA. Electrical Watt Rating and Power Consumption Spare Coil Part No. Standard Coil and AC General Purpose Explosionproof Class of Insulation DC Watts Watts VA Holding VA Inrush AC DC AC DC F F F Standard Voltages 2, 120, 20, 80 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz). 6, 12, 2, 120, 20 volts DC. Must be specified when ordering. Other voltages available when required Nominal Ambient Temperature Ranges: AC: 32 F to 125 F (0 C to 52 C) DC: 32 F to 10 F (0 C to 0 C) Solenoid Enclosures Standard: Watertight, Types 1, 2, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalog number) Approvals: CSA certified. UL listed, as indicated. Normally Closed Valves FM approved. Meets applicable CE directives. 27

30 Specifications (English units) Operating Pressure Differential (psi) Max. AC Max. DC Max. Fluid Temp. F Brass Body Stainless Steel Body Insulation ➁ Pipe (ins.) Orifice (ins.) Cv Flow Factor Air- Inert Gas Water Lt. 300 SSU Air- Inert Gas Water Lt. 300 SSU AC DC Catalog Number Ref. No. UL ➂ Listing Catalog Number Ref. No. UL ➂ Listing AC DC NORMALLY CLOSED (Closed when de-energized), NBR Disc 1/8 3/ G G /F 10.6/F 1/8 3/ G G /F 10.6/F 1/8 1/ G G /F 10.6/F 1/ 3/ G G /F 10.6/F 1/ 3/ G /F 11.6/F 1/ 3/ G /F - 1/ 3/ G G /F 10.6/F 1/ 1/ G G /F 10.6/F 1/ 1/ G /F 11.6/F 1/ 5/ G G /F 11.6/F 1/ 7/ G G /F 11.6/F 1/ 7/ G G /F 10.6/F 1/ 9/ G /F 11.6/F 1/ 9/ G G /F 22.6/F 1/ 9/ G G /F 10.6/F 3/8 1/ G G /F 10.6/F 3/8 5/ G G /F 11.6/F 3/8 7/ G G /F 11.6/F 3/8 9/ G G /F - NORMALLY OPEN (Open when de-energized), NBR Disc (except where noted) 1/8 1/ G G /F 10.6/F 1/8 3/ G G /F 10.6/F 1/8 1/ G G /F 10.6/F 1/ 3/ G260 ➀ G130 ➀ /F 11.6/F 1/ 3/ G261 ➀ G13 ➀ /F 11.6/F 1/ 1/ G G /F 11.6/F 1/ 5/ G G /F 11.6/F 1/ 7/ G G /F 11.6/F 1/ 9/ G G /F 11.6/F Notes: ➀ Cast UR disc supplied as standard. ➁ On 50 hertz service, the rating for the 6.1/F solenoid is 8.1 watts. ➂ Safety Shutoff Valve; General Purpose Valve. Refer to Engineering Section (Approvals) for details. 28

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

% ^ ) 1.4 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 1.4 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power 4.4 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /4" to " NPT / 3/ Features Molded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Increased ambient

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

High Pressure Solenoid Valves

High Pressure Solenoid Valves High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, & other High Pressure Gases High Pressure Cryogenics Flammable Liquids & Gases

More information

PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8

PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8 PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8 NC OUT IN 2/2 Series 110 EATURES Compact pilot boxes with direct operated, integrated pilot valves Especially designed

More information

Four-Way Valves. Accessories TABLE OF. Rotary and Smart. Actuator Motors

Four-Way Valves. Accessories TABLE OF. Rotary and Smart. Actuator Motors TABLE OF CONTENTS 389 We stock more than 2,000 different ASCO solenoid valves, repair kits, and replacement coils. What we don t stock, we can usually get from the factory within 5 working days! As the

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

High Pressure Solenoid Valves

High Pressure Solenoid Valves High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, Hydrogen & other High Pressure Gases High Pressure Cryogenics Flammable Liquids

More information

2/2-way Solenoid Valve with servo diaphragm

2/2-way Solenoid Valve with servo diaphragm 2/2-way Solenoid Valve with servo diaphragm Type 5282 can be combined with... Pivoted armature pilot drive also with emergency manual override Media separated Circuit function can be modified (NC NO) Adjustable

More information

2/2-way Solenoid Valve for liquids and gases

2/2-way Solenoid Valve for liquids and gases 2/2-way Solenoid Valve for liquids and gases Type 6213EV can be combined with... Coupled spring diaphragm system opened without differential pressure Waterhammer free and low noise HP00 version with increased

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

MICRO-MINIATURE SOLENOID VALVES

MICRO-MINIATURE SOLENOID VALVES MICRO-MINIATURE SOLENOID VALVES MICRO-MINIATURE SOLENOID VALVES General Service Valves Isolation Valves Pinch Valves Manifolds ASCO Scientific is a leading manufacturer of high quality, Micro-Miniature

More information

Valve proving system VPS 504 Series S06 (120Vac) Series S05 (24Vdc)

Valve proving system VPS 504 Series S06 (120Vac) Series S05 (24Vdc) Valve proving system VPS 504 Series S06 (120Vac) Series S05 (24Vdc) Approvals: VPS 504 S06 (120Vac) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (for USA) Technical Information Letter R-15

More information

4 Nuclear Catalog. Nuclear Products Qualified to IEEE Specifications. Solenoid Valves. Check Valves. Pressure & Temperature Switches

4 Nuclear Catalog. Nuclear Products Qualified to IEEE Specifications. Solenoid Valves. Check Valves. Pressure & Temperature Switches 4 Nuclear Catalog Nuclear Products Qualified to IEEE Specifications Solenoid Valves Check Valves Pressure & Temperature Switches Hydramotor Actuators www.ascovalve.com Index Engineering Information 2-8

More information

VALVES N.C. FOR REFRIGERATING SYSTEMS

VALVES N.C. FOR REFRIGERATING SYSTEMS SOLENOID VALVES 11 VALVES N.C. FOR REFRIGERATING SYSTEMS APPLICATIONS The valves illustrated herein are designed for use with refrigerant fluids CFC, HCFC and HFC. OPERATION All valves are normally closed

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series Series VQ0 VCH VDW VQ

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot

More information

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL

More information

Zone Valves and Parts (Honeywell)

Zone Valves and Parts (Honeywell) 28/11/14 B49 Zone Valves - Two Way Fan Coil Zone Valves and Parts (Honeywell) Two-way Fan Coil Valve, the VU53 high pressure zone valves are used to control the flow of hot or chilled water in commercial

More information

Data Sheet. Deluge Valve Model DS Straight Pattern & DA Angle Pattern. A New dimension in Deluge Valve technology. Deluge Valve.

Data Sheet. Deluge Valve Model DS Straight Pattern & DA Angle Pattern. A New dimension in Deluge Valve technology. Deluge Valve. A New dimension in Deluge technology Deluge Typical Applications Petroleum & Refineries Foam Application Power plants & Transformers Gas/LNG storage Tanks Marine/Ships Offshore Platforms Deluge Skid Optional

More information

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems Dynamic Solutions Leadership and Innovation in Valve Products and Valve Systems At ASCO, Valve Performance Begins and Ends With People 4 First of all, it begins with the people we serve. It is from them

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Installation & Maintenance Instructions OPEN-- FRAME, GENERAL PURPOSE, WATERTIG/EXPLOSIONPROOF SOLENOIDS r SERIES 8003G/H 8202G/H (Section1of2) SERVICE NOTICE ASCOr solenoid valves with design change letter

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable

More information

Pressure relief valves type ARAM two stage, in line mounting - G 3/4" and G 1 1 /4" threaded ports

Pressure relief valves type ARAM two stage, in line mounting - G 3/4 and G 1 1 /4 threaded ports www.atos.com Table C04520/E Pressure relief valves type ARAM two stage, in line mounting G 3/4" and G 1 1 /4" threaded ports ARAM20/20...E ARAM32.../V ARAM are two stage pressure relief valves with balanced

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

[2012] STC Valve [FREQUENTLY ASKED QUESTIONS]

[2012] STC Valve [FREQUENTLY ASKED QUESTIONS] [2012] STC Valve [FREQUENTLY ASKED QUESTIONS] Table of Contents Technical Issues... 4 I have a Normally Open (NO) solenoid valve, but if I blow through the valve, it is closed. Did I receive a Normally

More information

V4295A,S; V8295A,S Solenoid Gas Valves

V4295A,S; V8295A,S Solenoid Gas Valves V4295A,S; V8295A,S Solenoid Gas Valves INSTALLATION INSTRUCTIONS FEATURES APPLICATION The electrically operated V4295A, S and V8295A, S Solenoid Gas Valves control the flow of natural and LP (liquefied

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series inline Manifold mounting 5 stacking sub-base non plug-in 100 Manual operator 00 Sealed solenoid enclosure Armature 55 56 57

More information

Direct acting 2 port solenoid valve (general purpose valve) NC (normally closed) type Port size: Rc1/8, Rc1/4

Direct acting 2 port solenoid valve (general purpose valve) NC (normally closed) type Port size: Rc1/8, Rc1/4 Direct acting port solenoid valve (general purpose valve) Series NC (normally closed) type Port size: Rc/, Rc/ JIS symbol Common specifications Working fluid Working pressure differential range MPa Max.

More information

Coil Classification: Class F standard, Class H available Class B standard on V9xx models

Coil Classification: Class F standard, Class H available Class B standard on V9xx models Direct Acting & Pilot Operated Valves 1/8" - 1/2" General Description: Direct Acting and Pilot Operated valves are used in applications for actuation of double acting cylinders and piloting of larger control

More information

Direct Operated 3 Port Solenoid Valve For Air, Water, Oil, Steam

Direct Operated 3 Port Solenoid Valve For Air, Water, Oil, Steam CAT.ES0-6 Direct Operated Port Solenoid Valve For Air, Water, Oil, Steam Reduced power consumption ( specification). W. 8 W W 0. W.. W 6 W New VX Series VX/ / Reduced power consumption Improved corrosion

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid 2- and 3-way Solenoid Valves for Gas and Liquid SV10: Vacuum to 3000 psig SV430: Vacuum to 3000 psig SV20: Vacuum to 6000 psig SV460: Vacuum to 6000 psig SV30: Vacuum to 3000 psig Circle Seal Controls

More information

WELCOME TO MAGNATROL

WELCOME TO MAGNATROL Catalog 6 BULLETIN 6-INDEX WELCOME TO MAGNATROL Process Control Solenoid Valves For Water Oil Air Gas Steam Cryogenics Vacuum Solvents Brine Oxygen Corrosive Fluids Magnatrol Valve Corp. Established 1936

More information

Solenoid Valves Catalogue

Solenoid Valves Catalogue Solenoid Valves Catalogue lcon Solenoid Valve Range US Keeping the World Flowing Contents Section Page Section Page Introduction U Series 4 U Series Exd 6 U/U Series 8 U/U Series Exd 0 68 Series (Cryogenic)

More information

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below: Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees

More information

Application Feature Valve Nominal Liquid Capacity R-22 (in tons)*

Application Feature Valve Nominal Liquid Capacity R-22 (in tons)* EMERSON CLIMATE TECHNOLOGIES-Solenoid Valves & Coils Quick Select Guide Applications Application Feature Valve Nominal Liquid Capacity R-22 (in tons)* Nominal Liquid Capacity R-410A (in tons)* Liquid Line

More information

Max-Air Technology Inc. NAMUR SOLENOID VALVE 4 and NEMA 7. Technical Data. Material

Max-Air Technology Inc. NAMUR SOLENOID VALVE 4 and NEMA 7. Technical Data. Material Technical Data Port connections Inlet and exhaust Outlet DIN connector (NEMA 4 Pictured) NAMUR SOLENOID VALVE NEMAs 4 and NEMA 7 1/4 NPT NAMUR interface 1/2" NPT Pressure Range: 30 to 150 PSI Flow factor:

More information

BERMAD Waterworks. High Pressure, Booster Pump Control Valve Active Check Valve. 800 Series. Model 840. Features and Benefits

BERMAD Waterworks. High Pressure, Booster Pump Control Valve Active Check Valve. 800 Series. Model 840. Features and Benefits High Pressure, Booster Pump Control Valve Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

STC 2P Series Solenoid Valves

STC 2P Series Solenoid Valves STC 2P160-250 Series Solenoid Valves 2P160-250 Series Solenoid Valve Specifications Valve Model 2P160-1/2 2P200-3/4 2P250-1 Valve Type Action 2 Way, Normally Closed (NC) Direct Lift Diaphragm, Uni-Directional

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Series 1, 2 & 6 Options selector. Port 4 = 1/8" NPT 5 = 1/4" NPT (Series 6* only) 7 = #10-32 UNF 8 = 1/4-28 UNF

Series 1, 2 & 6 Options selector. Port 4 = 1/8 NPT 5 = 1/4 NPT (Series 6* only) 7 = #10-32 UNF 8 = 1/4-28 UNF KIP Isolation Valves Ideal for control of corrosive and aggressive media Elastomer diaphragm provides protection from aggressive, corrosive, and gritty media Isolation valves can be equipped with a low

More information

STC 2S Series Solenoid Valves

STC 2S Series Solenoid Valves STC 2S025-050 Series Solenoid Valves 2S025-050 Series Solenoid Valve Specifications Valve Model 2S025-1/4 2S035-1/4 2S040-3/8 2S050-1/4 2S050-3/8 Valve Type Action 2 Way, Normally Closed (NC) Direct Acting,

More information

THE BASICS OF PRESSURE REGULATORS

THE BASICS OF PRESSURE REGULATORS THE BASICS OF PRESSURE REGULATORS Contents The Basics of Pressure Regulators Material Fluid used (gas, liquid, toxic or flammable) Temperature Operating Pressures Flow Requirements Size & Weight Pressure

More information

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each

More information

Solenoid Valves and Their Importance in Refrigeration Systems. October 2007

Solenoid Valves and Their Importance in Refrigeration Systems. October 2007 Solenoid Valves and Their Importance in Refrigeration Systems October 2007 Overview Introduction Solenoid valves play an important role within refrigeration and air conditioning systems, controlling the

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Republic/Manatrol Hydraulic and Pneumatic Control Valves. Catalog HY /US FOR POSITION ONLY

Republic/Manatrol Hydraulic and Pneumatic Control Valves. Catalog HY /US FOR POSITION ONLY Republic/Manatrol Hydraulic and Pneumatic Control Valves Catalog HY14-3000/US FOR POSITION ONLY Republic/Manatrol Valves Hydraulic and Pneumatic Controls WARNING FAILUR OR IMPROPR SLCTION OR IMPROPR US

More information

Pressure relief valves type AGAM two stage, subplate mounting - ISO 6264 size 10, 20 and 32

Pressure relief valves type AGAM two stage, subplate mounting - ISO 6264 size 10, 20 and 32 www.atos.com Table C06619/E Pressure relief valves type AGAM two stage, subplate mounting ISO 6264 size 10, 20 and 32 1 MODEL CODE AGAM10/11...E AGAM20/.../V AGAM are two stage pressure relief valves with

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

Solenoid Valves. For use in Deluge and Preaction Systems With an Electric Release

Solenoid Valves. For use in Deluge and Preaction Systems With an Electric Release Solenoid Valves Bulletin 718 Rev. A Bulletin 718 Rev. A For use in Deluge and Preaction Systems With an Electric Release Features 1. Normally Closed (Energize to Open) 2. 24 VDC (Most Common) 120 VAC -

More information

Sporlan V-Series Ruby Seat Solenoid Valves

Sporlan V-Series Ruby Seat Solenoid Valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Sporlan V-Series Ruby Seat Solenoid Valves RACE Catalogue 30-10-8 UK,

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches 2100 and 2100E Level Switches Product Bulletin Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches Fisher 2100 on-off pneumatic switch and 2100E electric switch sense (shown in figure 1) high

More information

Solenoid and Air Operated Valves. Supporting Fleet Operations for Over 60 Years

Solenoid and Air Operated Valves. Supporting Fleet Operations for Over 60 Years 4 Solenoid and Air Operated Valves Supporting Fleet Operations for Over 60 Years This catalog describes solenoid and air operated valves, representative of those manufactured by ASCO Valve, Inc. to meet

More information

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL) HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL) The oil level regulator controls the oil level in the compressor crankcase with a float operated valve. Oil level regulators are designed to attach

More information

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

SECTION DOMESTIC WATER PUMPS

SECTION DOMESTIC WATER PUMPS SECTION 22 11 23 DOMESTIC WATER PUMPS PART 1 - GENERAL 1.1 DESCRIPTION A. Hot water circulating pumps, hot water recirculation pumps, and domestic cold water recirculation pumps. 1.2 RELATED WORK A. Section

More information

Parker One Pneumatic. A complete range of pneumatic system components

Parker One Pneumatic. A complete range of pneumatic system components A complete range of pneumatic system components Catalogue PDE600PNUK March 011 aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

The GDP has the following unit dimensions: 251 B X 235 L X 182 H (mm) (9.9 B X 9.3 L X 7.2 H (inches))

The GDP has the following unit dimensions: 251 B X 235 L X 182 H (mm) (9.9 B X 9.3 L X 7.2 H (inches)) MDE-4168A Global Dispensing Pump Model GDP- 090 Product Specification January 2003 Purpose The purpose of this specification is to provide technical data on the Blackmer Global Dispensing Pump (GDP) Model

More information

Baumann 24003 3 Way Bronze or Stainless Steel Control Valve

Baumann 24003 3 Way Bronze or Stainless Steel Control Valve Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control

More information

PRESSURE REGULATORS GAS LOW PRESSURE PRESSURE REDUCING

PRESSURE REGULATORS GAS LOW PRESSURE PRESSURE REDUCING GAS LOW PRESSURE PRESSURE REDUCING APPLICATIONS: Low pressure regulator for maintaining vapor pressure on storage tanks, controlling compressor by-pass for gas recirculation and maintaining low pressure

More information

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves 2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

ON-OFF FLOAT CONTROL VALVE

ON-OFF FLOAT CONTROL VALVE ON-OFF FLOAT CONTROL VALVE (4 and Smaller) /08 Schematics Opens when float reaches low level stop Closes when float reaches high level stop Low and High Level stop collars are adjustable P/L X Standard

More information

SQUARE D INDUSTRIAL CONTROL PRODUCTS

SQUARE D INDUSTRIAL CONTROL PRODUCTS SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and

More information

VP 150 QT (series 2013)

VP 150 QT (series 2013) PRESSURE RELIEF DEVICE VP 150 QT (series 2013) Features The pressure relief valve VP150QT have been specially designed for use on transformers in which is not admitted any external pollution due to oil

More information

PR*SP - PR*SPU - PILOT OPERATED PRESSURE RELIEF VALVE SERIES

PR*SP - PR*SPU - PILOT OPERATED PRESSURE RELIEF VALVE SERIES CONTINENTAL HYDRAULICS PR*SP - PR*SPU PILOT OPERATED PRESSURE RELIEF VALVE SERIES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM POWERFUL PR*SP - PR*SPU

More information

167D Series Switching Valves

167D Series Switching Valves June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are

More information

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Two normally closed safety shutoff valves in one housing; each with the following approval. CSA Certified ANSI Z21.21

More information

Flow controller with integrated control valve (PN 25) AVQM - return and flow mounting

Flow controller with integrated control valve (PN 25) AVQM - return and flow mounting Data sheet Flow controller with integrated control valve (PN 25) AVQM - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: - AMV 150 1) - AMV(E) 10 1)

More information

Precision Solenoid Valves

Precision Solenoid Valves Precision Solenoid Valves Solenoid Valves for gas General Purpose Valves Specialty Solenoid Valves n Didn t see what you re looking for? Let us review your requirements and chances are we can help solve

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

ISO Star Series Valves A long life (100 to 200 million cycles) precision spool and sleeve directional control air valve

ISO Star Series Valves A long life (100 to 200 million cycles) precision spool and sleeve directional control air valve Section 5 ISO Star Series Valves A long life (100 to 200 million cycles) precision spool and sleeve directional control air valve Contents Features and Benefits............VAL-5-2 Specifications and Technical

More information

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air CAT.EUS0- A -UK Direct Operated Port Solenoid Valve For Water, Oil, Steam, Air New Series VX// Reduction of power consumption ( specification) W. W W W.. W 0. W Low power consumption type: 0. W (Held at

More information

HIGH PERFORMANCE BALL VALVES

HIGH PERFORMANCE BALL VALVES HIGH PERFORMANCE BALL VALVES H-6800 & H-6800 CNG SERIES H-6800 FEATURES Certified for ISO 15848-1:2006(E) On/off-service ball valve with 2-way pattern Diverter-service ball valve with 3-way pattern Stainless

More information

STC 3S012-020-A Series Solenoid Valves

STC 3S012-020-A Series Solenoid Valves STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,

More information

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0. ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)

More information

GW C300 FLUID CONTROL VALVE PRESSURE REGULATING WITH ACTUATOR AND SOLENOID

GW C300 FLUID CONTROL VALVE PRESSURE REGULATING WITH ACTUATOR AND SOLENOID Ni Al Bronze PART NUMBER Super Duplex Titanium 3 64.515.44 64.515.46 64.515.47 4 64.516.44 64.516.46 64.516.47 6 64.517.44 64.517.46 64.517.47 8 64.518.44 64.518.46 64.518.47 10 64.519.44 64.519.46 64.519.47

More information

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to

More information

Types 66R and 66RR Low-Pressure Relief Valves

Types 66R and 66RR Low-Pressure Relief Valves November 2009 Types 66R and 66RR Low-Pressure Relief Valves W1953 W1908 TYPE 66R RELIEF VALVE TYPE 66RR RELIEF VALVE Figure 1. Typical Constructions Introduction Types 66R and 66RR low-pressure throttling

More information

Solenoid valves 6240

Solenoid valves 6240 Solenoid valves 6240 Solenoid valve 6240 The compact power valve Gases, drinking water, hot liquids and steam are the application focuses of the type 6240 piston valve. The body, seals and design were

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

AV5A Air Admittance Valve With Couplings

AV5A Air Admittance Valve With Couplings AVA Air Admittance Valve With Couplings The AVA is manufactured in aluminum alloy. It has a control knob attached to a screwactuated plunger: turn the control knob clockwise to close the valve. A nitrile

More information

Ratio Regulator/ Zero Governor. FRG/6 Series

Ratio Regulator/ Zero Governor. FRG/6 Series Ratio Regulator/ Zero Governor FRG/6 Series CSA Certified ANSI Z21.18 CSA 6.3 CSA Requirement #5.01 Zero Governor and Gas/Air Regulator File # 15406 US and Canadian Models FRG 05/6 FRG 0/6 FRG 10/6 FRG

More information

AB/AG. General purpose direct acting 2, 3 port solenoid valve. (General purpose valve) For air, vacuum, water, oil CONTENTS.

AB/AG. General purpose direct acting 2, 3 port solenoid valve. (General purpose valve) For air, vacuum, water, oil CONTENTS. / (eneral purpose valve) eneral purpose direct acting, 3 port solenoid valve For air, vacuum, water, oil N/ US/ F/ F/ Overview The general purpose valve series enables control of various types of fluids

More information

Pilot Operated Pressure Relief Valves Series R4V / R6V

Pilot Operated Pressure Relief Valves Series R4V / R6V Characteristics Series RV / R6V Pilot operated pressure relief valves series RV (DIN 230 Form D) and R6V (DIN 230 Form E) consist of a manually adjusted pilot stage and a seated type main stage. A vent

More information

BVP70, BVPS70 & BVE70 Series

BVP70, BVPS70 & BVE70 Series BVE70 BVPS70 BVP70 BVP70, BVPS70 & BVE70 Series Pneumatically & Electrically Actuated Tube Compression End Style Valves 2 BVP70, BVPS70 & BVE70 Series Ball Valves Ball Valve - MATERIALS OF CONSTRUCTION

More information

Accumulators and Receivers

Accumulators and Receivers aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Accumulators and Receivers Catalog C-1, October 2007 Page 2 / Catalog

More information

VTA Series Pneumatic Three Way Air Switching Valves

VTA Series Pneumatic Three Way Air Switching Valves FANs 718, 977 Product Bulletin VTA Series Issue Date 0596 VTA Series Pneumatic Three Way Air Switching Valves The VTA Series Three Way Air Switching Valves are designed to switch the flow of air from onesupply

More information