Low and High Static Pressure Fan Coil Units. VH2N 03 to 27. Technical Brochure. TM VH2N-A.1GB Date : June 2006 Supersedes : None

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Low and High Static Pressure Fan Coil Units. VH2N 03 to 27. Technical Brochure. TM VH2N-A.1GB Date : June 2006 Supersedes : None"

Transcription

1 Low and High Static Pressure Fan Coil Units VH2N 03 to 27 Technical Brochure TM VH2N-A.1GB Date : June 2006 Supersedes : None

2 Design Features Presentation The VH2N fan coil units has been specially designed to meet the job requirements that call for false-ceiling installations and for air distribution by ductwork requiring low and high static pressure (up to 220 Pa for larger units). Casing Fabricated from 1.0 mm thick galvanized sheet steel with the fixing brackets located at the top part of the casing for installation to the ceiling. The condensate drain pan is made from 1.0 mm thick galvanized sheet steel, painted and is externally insulated by 2 mm thick closed cell polyethylene foam, having M1 fire classification. An optional auxiliary drain pan (supplied with valves) can be provided to collect condensates from coils headers. Access to internal components (fan-motor assembly and coils) for service and maintenance works is facilitated by dismantling the central bottom panel of the fan coil unit, without removing the distribution ducts. Fixation The unit is supplied with 4 slotted fixing brackets as standard. Coil compartment It is lined with 10 mm thick closed cell polyethylene foam insulation, having M1 fire classification. It incorporates water coils which are fitted with 1/2"Ø female threaded couplings for units up to model VH2N 10 and with Rc 3/4" to Rc 1"1/4 male threaded couplings for larger units. Coils have 4 or 5 rows and 3+1 or 4+1 rows, respectively available for 2 or 4 pipe systems. Coils are leak tested under water (21 bar) and are suitable for a maximum working pressure of 10 bar. Fan compartment It incorporates a fan-motor assembly of which the fan is composed of double inlet forward curved type aluminium wheels and galvanized sheet steel scrolls. Motor is of direct drive type having 3 or 6 speeds according to the models. Motor is suitable for nominal voltage of 230 V / 1 Ph / 50 Hz and is equipped with a built-in thermal overload protection of automatic reset type. Air filter Filter consists of cleanable synthetic media (sewn on wire frame) having G2 or G3 classification. The G3 synthetic media on a reinforced frame can be supplied as optional. Filter is removable and is easily pulled out downward for cleaning or replacement, after removing the access metal plate. Options and accessories Electric heater for 2-pipe/2-wire system Electric heater consists of sheathed type heating elements equipped with a manual reset and an automatic reset high temperature cutout switches. The electric heater On/Off control, made thanks to a relay, can be mounted as optional. Standard voltage is single phase 230 V. Regulation valves On/Off (thermal type actuator), 2-way or 4-way type for 2-pipe or 4-pipe systems. Valves are not available for model VH2N 27. Valves for models VH2N 03/05/07/10 are supplied mounted, those for models VH2N 15/18/21/24 are supplied loose. Controls Electromechanical, electronic or digital type. Fan speed relay Relay for fan speed control can be mounted as optional for models VH2N 15/18/21/24/27. Integrated fan plenum with or without air filter Fan-motor assembly Electrical box with grommets Cooling and heating coils (4-pipe system) Cooling coil connecting headers equipped with air vent and drain plug Heating coil connecting headers equipped with air vent and drain plug Auxiliary condensate drain pan (optional) Page 2

3 Air Flow Data VH2N 03 - Air Flow (m 3 /h) Speeds V1 V2 V3 V4 V5 V6 Filter External static pressure (Pa) Without G G Without G G Without G G Without G G Without G G Without G G VH2N 05 - Air Flow (m 3 /h) Speeds V1 V2 V3 V4 V5 V6 Filter External static pressure (Pa) Without G G Without G G Without G G Without G G Without G G Without G G Page 3

4 Air Flow Data (continued) VH2N 07 - Air Flow (m 3 /h) Speeds V1 V2 V3 V4 V5 Filter External static pressure (Pa) Without G G Without G G Without G G Without G G Without G G VH2N 10 - Air Flow (m 3 /h) Speeds V1 V2 V3 V4 V5 Filter External static pressure (Pa) Without G G Without G G Without G G Without G G Without G G VH2N 15 & 18 - Air Flow (m 3 /h) Speeds V1 V2 V3 V4 Filter External static pressure (Pa) Without G G Without G G Without G G Without G G Page 4

5 Air Flow Data (continued) VH2N 21 - Air Flow (m 3 /h) Speeds V1 V2 V3 V4 Filter External static pressure (Pa) Without G G Without G G Without G G Without G G VH2N 24 - Air Flow (m 3 /h) Speeds V1 V2 V3 Filter External static pressure (Pa) Without G G Without G G Without G G VH2N 27 - Air Flow (m 3 /h) Speeds V1 V2 V3 Filter External static pressure (Pa) Without G G Without G G Without G G Page 5

6 Electric Heating Coil Data Sizes VH2N 03 VH2N 05 VH2N 07 VH2N 10 VH2N 15 VH2N 18 VH2N 21 VH2N 24 VH2N 27 BE BE Capacity (W) BE BE BE Fan Motor Electrical Data Motors absorbed V/1 Ph/50 Hz Sizes Fan speed VH2N 03 VH2N 05 VH2N 07 VH2N 10 V V V V V V Sizes Fan speed VH2N 15 VH2N 18 VH2N 21 VH2N 24 VH2N 27 V V V V (*) Motor maximum absorbed data given for operation with 230 V/1 Ph/50 Hz supply and 0 Pa external static pressure with G2 filter. Page 6

7 Sound Power Levels Lw VH2N 03 Lw in db(a) Fan speed V1 V2 V3 V4 V5 V6 Return * Discharge * Radiated ** VH2N 05 Lw in db(a) Fan speed V1 V2 V3 V4 V5 V6 Return * Discharge * Radiated ** VH2N 07 Lw in db(a) Fan speed V1 V2 V3 V4 V5 Return * Discharge * Radiated ** VH2N 10 Lw in db(a) Fan speed V1 V2 V3 V4 V5 Return * Discharge * Radiated ** VH2N 15, 18, 21 Lw in db(a) Fan speed V1 V2 V3 V4 Return * Discharge * Radiated ** VH2N 24 and 27 Lw in db(a) Fan speed V1 V2 V3 Return * Discharge * Radiated ** (*) Data given for 0 Pa external static pressure. (**) Data given for 50 Pa external static pressure at maximum fan speed. Coil Water Volume Water volume (in litres) Sizes 4 pipes 2 pipes Cooling Heating VH2N VH2N VH2N VH2N VH2N VH2N VH2N VH2N VH2N Page 7

8 Performance Data in Cooling Mode - 2-pipe system VH2N sizes Speed V1 V2 V3 V4 V5 V6 Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Performance data based on : Air : 27 C/19 C (wet bulb), Chilled water : 7/12 C. Units with G2 filter and 50 Pa external static pressure. Performance Data in Cooling Mode - 4-pipe system VH2N sizes Speed V1 V2 V3 V4 V5 V6 Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Air flow m 3 /h P total W P sensible W Performance data based on : Air : 27 C/19 C (wet bulb), Chilled water : 7/12 C. Units with G2 filter and 50 Pa external static pressure. Page 8

9 Performance Data in Heating Mode - 2-pipe system VH2N sizes Speed V1 V2 V3 V4 V5 V Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Performance data based on : - Air : 20 C, entering water : 50 C, water flow same as that in cooling mode. - Units with G2 filter and 50 Pa external static pressure. Performance Data in Heating Mode - 4-pipe system VH2N sizes Speed V1 V2 V3 V4 V5 V Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Air flow m 3 /h P heat W Performance data based on : - Air : 20 C, hot water : 70/60 C. - Units with G2 filter and 50 Pa external static pressure. Page 9

10 Water Pressure Drops - Cooling Mode - 2-pipe system Pressure drop (kpa) 1 VH2N 03 2 VH2N 05 3 VH2N 07 4 VH2N 10 5 VH2N 15 6 VH2N 18 7 VH2N 21 8 VH2N 24 9 VH2N 27 Water flow (x100 l/h) Water Pressure Drops - Heating Mode - 2-pipe system Pressure drop (kpa) 1 VH2N 03 2 VH2N 05 3 VH2N 07 4 VH2N 10 5 VH2N 15 6 VH2N 18 7 VH2N 21 8 VH2N 24 9 VH2N 27 Water flow (x100 l/h) Page 10

11 Water Pressure Drops - Cooling Mode - 4-pipe system 1 VH2N 03 2 VH2N 05 Pressure drop (kpa) 3 VH2N 07 4 VH2N 10 5 VH2N 15 6 VH2N 18 7 VH2N 21 8 VH2N 24 9 VH2N 27 Water flow (x100 l/h) Water Pressure Drops - Heating Mode - 4-pipe system Pressure drop (kpa) 1 VH2N 03 2 VH2N 05 3 VH2N 07 4 VH2N 10 5 VH2N 15 6 VH2N 18 7 VH2N 21 8 VH2N 24 9 VH2N 27 Water flow (x100 l/h) Page 11

12 Dimensional Data and Weight - VH2N 03 Dimensions in mm. Unit size Operating weight Weight definition VH2N kg Unit with 4-row coil, without valve and without control. Page 12

13 Dimensional Data and Weight - VH2N 05, 07 and 10 Unit size A B C D E F G H I J K L M N VH2N VH2N VH2N Dimensions in mm. Unit size Operating weight Weight definition VH2N kg Unit with 4-row coil, without valve and without control. VH2N kg Unit with 4-row coil, without valve and without control. VH2N kg Unit with 5-row coil, without valve and without control. Page 13

14 Dimensional Data and Weight - VH2N 15, 18, 21, 24 and 27 Unit size A B C D E F G H I J K L M N P Q R S T VH2N VH2N VH2N VH2N VH2N Dimensions in mm. Unit size Operating weight Weight definition VH2N kg Unit with 3-row coil, without valve and without control. VH2N kg Unit with 4-row coil, without valve and without control. VH2N kg Unit with 5-row coil, without valve and without control. VH2N kg Unit with 4-row coil, without valve and without control. VH2N kg Unit with 5-row coil, without valve and without control. Page 14

15 Definition of the Service Sides The service side is determined by coil connection side when observer is looking at the unit from the discharge side. LEFT-HAND service side RIGHT-HAND service side Page 15

16 As part of our ongoing product improvement programme, our products are subject to change without prior notice. Non contractual photos. Your distributor : CAC Export Department 42 cours Jean-Jaurès Pons - France Tel. : +33 (0) Fax : +33 (0)

High Static Pressure Ductable Fan Coil Unit Models 07 to 27

High Static Pressure Ductable Fan Coil Unit Models 07 to 27 VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 5.3 to 26.9kW 4.1 to 22.6kW 800 to 4650 m 3 /h VH 1 General Characteristics Presentation The new ducted high static pressure fan coil units

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Packaged Air Conditioner - Water Cooled Vertical Type Model 25

Packaged Air Conditioner - Water Cooled Vertical Type Model 25 Refrigerant R407C CX Packaged Air Conditioner - Water Cooled Vertical Type Model 25 8.0kW CX 25 1 Product Code Model Power supply Product code CX 25 230V / 1 ~ / 50 Hz 7XU012153 CX 25 CX 25 2 CX 25 General

More information

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application 42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code

More information

KOG LN. Low Noise Chilled Water Cassettes Models 9, 12 & to 5.7kW. 1.6 to 4.6kW. 290 to 830 m 3 /h

KOG LN. Low Noise Chilled Water Cassettes Models 9, 12 & to 5.7kW. 1.6 to 4.6kW. 290 to 830 m 3 /h KOG LN Low Noise Chilled Water Cassettes Models 9, 12 & 18 1.7 to 5.7kW 1.6 to 4.6kW 290 to 8 m 3 /h 1 KOG LN 9 / KOG LN 12 / KOG LN 18 Design Features Introduction The new low noise chilled water cassettes

More information

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application (200 to 2000 CFM)

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application (200 to 2000 CFM) Turn to the Experts 42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application (200 to 2000 CFM) 42DF 42CG 42DE 42CE 42DC MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER

More information

NEW Air Conditioning

NEW Air Conditioning NEW Including sizes 6 and 7 Cert. n 0/ www.eurovent-certification.com www.certiflash.com Air Conditioning High Pressure Fan Coil Units CONTENTS Sizes Introduction Page Construction features Page Dimensions,

More information

Carisma CRSO. All range is compliant with the new ERP 2013 Regulation (EU) High Pressure Fan Coil Unit with Asynchronous Motor

Carisma CRSO. All range is compliant with the new ERP 2013 Regulation (EU) High Pressure Fan Coil Unit with Asynchronous Motor Carisma CRSO igh Pressure Fan Coil Unit with Asynchronous Motor Range includes air rates (from 375 to 2220 m 3 /h) each equipped with 3 or row coil and with the possibility to add a 1 or 2 row coil for

More information

Mirage over door heater. Features: Electric and LPHW versions. Compact and Versatile. Suitable for mounting up to 3.0m high from finished floor level.

Mirage over door heater. Features: Electric and LPHW versions. Compact and Versatile. Suitable for mounting up to 3.0m high from finished floor level. Features: Electric and LPHW versions. Compact and Versatile Suitable for mounting up to 3.0m high from finished floor level. Recessed or surface mounted. Energy saving controls option available. Available

More information

YGFC. Fan Coil Units. Size: 02 ~ 12 Air Flow: 378 ~ 2524m 3 /h. Ceiling Concealed Type. Vertical Concealed Type. Vertical Exposed Type

YGFC. Fan Coil Units. Size: 02 ~ 12 Air Flow: 378 ~ 2524m 3 /h. Ceiling Concealed Type. Vertical Concealed Type. Vertical Exposed Type YGFC Fan Coil Units Ceiling Concealed Vertical Concealed Vertical Exposed Ceiling Exposed Size: ~ Air Flow: 38 ~ 5m 3 /h Content & Nomenclature CONTENT Design Physical Data Cooling Capacity Heating Capacity

More information

42DW. Horizontal Ducted Fan Coil Units. Nominal cooling capacity kw Nominal heating capacity kw. Features

42DW. Horizontal Ducted Fan Coil Units. Nominal cooling capacity kw Nominal heating capacity kw. Features Horizontal Ducted Fan Coil Units 42DW Nominal cooling capacity 5.5-12.7 kw Nominal heating capacity 7.3-17.9 kw The Carrier 42DW fan coil units offer reliable, economical cooling and heating for light

More information

INSTALLATION MANUAL. Terminals for built-in installation Master type. HWD

INSTALLATION MANUAL. Terminals for built-in installation Master type. HWD INSTALLATION MANUAL Terminals for built-in installation Master type. HWD 0071 0121 Section A TECHNICAL DATA Index page Description of standard unit 25 Technical data HWD 26 Functional spaces 26 Dimensioned

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

F A N C O N V E C T O R R A N G E

F A N C O N V E C T O R R A N G E FAN CONVECTOR RANGE Why Use a Fan Convector? Widely used in buildings such as schools, libraries, churches, hospitals, leisure centres, shops and offices fan convectors have for many years been universally

More information

Chilled Water Fan Coil Unit

Chilled Water Fan Coil Unit Chilled Water Fan Unit Model: HFCF02~HFCF14 Airflow Range: 200~2400m 3 /h Features and Benefits The Best Choice for Comfort The Best Results - Quiet Comfort Low noise permanent split capacitor motor. Metal

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14 Chilled Water Fan Coil Unit Model:HFCA Size 03~4 The Best Choice for Comfort =The Best Results Quiet Comfort Slope coil avoid air flow perpendicular impact Low noise permanent split capacitor motor Metal

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Installation Manual CLIFC Fan & Coil Variable Speed

Installation Manual CLIFC Fan & Coil Variable Speed Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

TECHNICAL MANUAL HEAT RECOVERY UNITS URE SERIES

TECHNICAL MANUAL HEAT RECOVERY UNITS URE SERIES TECHNICAL MANUAL HEAT RECOVERY UNITS URE SERIES SUMMARY 1. GENERAL FEATURES 2 2. VERSIONS AND COMPONENTS 2 3. ORIENTATIONS 3 4. NOMINAL TECHNICAL DATA 4 5. AVAILABLE ACCESSORIES 5 6. FAN CHARACTERISTICS

More information

QZSR Fan Coil. Key features. Specifications. Product code example Cassette Unit QZSR, QZSR-13-2-2-1

QZSR Fan Coil. Key features. Specifications. Product code example Cassette Unit QZSR, QZSR-13-2-2-1 Key features Vertical or horizontal installation Cooling ( pipes) Heating ( pipes or electrical heater) Available pressure up to 80 Pa ECM version for low energy consumption In line with innovative trends

More information

Cool Design for Homes and Offices

Cool Design for Homes and Offices AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners

More information

COMFORT LINE. Ductable comfort units. New ductable comfort unit "An innovative solution promoting wellbeing" comfort line...

COMFORT LINE. Ductable comfort units. New ductable comfort unit An innovative solution promoting wellbeing comfort line... New ductable comfort unit "An innovative solution promoting wellbeing" comfort line... n Because it is essential to offer solutions which meet our customers' expectations. n Because we need to develop

More information

Refrigerant R410A. Mini SysAqua DCI. 5.5 to 16.0kW. Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI

Refrigerant R410A. Mini SysAqua DCI. 5.5 to 16.0kW. Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI Refrigerant R4A Mini SysAqua DCI Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI 5.5 to 16.0kW Mini SysAqua DCI 1 Strength Points By introducing the variable speed in our packaged heat pump

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

50 AZs. Packaged Rooftop/Cooling Units. Nominal cooling capacity kw. Features

50 AZs. Packaged Rooftop/Cooling Units. Nominal cooling capacity kw. Features Packaged Rooftop/Cooling Units 0036 Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 50 AZs Nominal cooling capacity

More information

50XJ064, 074, 084, 094, 104 WATER-COOLED VARIABLE AIR VOLUME INDOOR SELF-CONTAINED SYSTEMS

50XJ064, 074, 084, 094, 104 WATER-COOLED VARIABLE AIR VOLUME INDOOR SELF-CONTAINED SYSTEMS 50XJ-3SB 50XJ064, 074, 084, 094, 104 WATER-COOLED VARIABLE AIR VOLUME INDOOR SELF-CONTAINED SYSTEMS PERFORMANCE DATA DIMENSION PRINTS PLENUM DIMENSION PRINT Copyright 2004 Carrier Corporation Syracuse,

More information

MARVAIR COMPAC AIR CONDITIONERS MODELS AVPA & AVPSA EXPLODED VIEW PARTS ID

MARVAIR COMPAC AIR CONDITIONERS MODELS AVPA & AVPSA EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS) 1 Panel, Back (Galvanized) M/04996-SP 2 Door, Front Top M/01294-XXSP 3 4 Door, Front Bottom w/slots 1,2 (shown) Door, Front Bottom w/ext. Fresh Air Hood (not shown)

More information

Air handling unit. REC Temovex 250S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 250S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 25S-EC-RS Experts on indoor climate in low-energy houses RT 25S-EC-RS REC Temovex 25S-EC-RS Made in Sweden ECO2 control system for low-energy and passive houses Comprises: - Air flow boost

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

COMMISSIONING OF HVAC SYSTEMS

COMMISSIONING OF HVAC SYSTEMS FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS

More information

Water Chillers - The range CH and RPW series

Water Chillers - The range CH and RPW series Water Chillers - The range CH and RPW series PIOVAN S.p.A. Cooling Centre 1 (1) Piovan Chiller Range Piovan Spa 03.2004 Modification reserved Water chillers A dedicated Cooling Centre Integration with

More information

The Next Generation Concealed Water Cooled Package Unit. Mon Feb

The Next Generation Concealed Water Cooled Package Unit. Mon Feb The Next Generation Concealed Water Cooled Package Unit Mon Feb 24 2014 Mon Feb 24 2014 Introducing the Next Generation Vertical Water Cooled Package Units Ideal for Apartments and Office Buildings Concealed

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS Made in Sweden ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for

More information

DESCRIPTION TECHNICAL GUIDE EMBASSY SERIES SINGLE PACKAGE AIR COOLED AIR CONDITIONERS

DESCRIPTION TECHNICAL GUIDE EMBASSY SERIES SINGLE PACKAGE AIR COOLED AIR CONDITIONERS DESCRIPTION YORK s self-contained air conditioning packages offer a complete line of unit options for indoor, through-the-wall installation for high rise and single story building applications. TECHNICAL

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

42WH Nominal cooling capacity kw Nominal heating capacity kw

42WH Nominal cooling capacity kw Nominal heating capacity kw Hydronic High-Wall-Fan Coil Units 42WH Nominal cooling capacity 1.4-2.1 kw Nominal heating capacity 1.9-3.2 kw These elegant hydronic high-wall units complete the Carrier range of water-cooled indoor units.

More information

High efficiency air/water reversible heat pumps type Geyser Mini Technical information manual

High efficiency air/water reversible heat pumps type Geyser Mini Technical information manual High efficiency air/water reversible heat pumps type Geyser Mini Technical information manual 2 GEYSER MINI Reversible heat pump Index Technical features 120 Basic version general technical data 124 Basic

More information

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay Original HVAC Units: Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue Photo Essay One fan motor draws air from the lower section of the unit,

More information

Stock Fan Coils & Unit Heaters

Stock Fan Coils & Unit Heaters Complete solutions for fan coil applications Stock Fan Coils & Unit Heaters Engineered for flexibility and performance High Quality Fan Coils For Every Application McQuay fan coil units have earned a reputation

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Chilled Water Fan Coil Units. Tailor Your Atmosphere

Chilled Water Fan Coil Units. Tailor Your Atmosphere Chilled Water Fan Coil Units Tailor Your Atmosphere About Us Heating & Air Conditioning Enterprises have recently grouped the names of it s divisions (HACE Royal Temp Golden Star) into (HACE), while preserving

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

PLUG and PLAY VRV Connection

PLUG and PLAY VRV Connection PLUG and PLAY VRV Connection All seasons Perfect c mfort Heating Air Conditioning Applied Systems Refrigeration Pricelist 2010 Air Handling Units for > VRV Indoor units and Air Handling Units on single

More information

1 General description

1 General description Specification SERIES: SyScroll 20-30 Air EVO HP TYPE: Air to water inverter driven heat pump TECHNOLOGY: scroll compressor / inverter driven CAPACITY RANGE: Cool ing 20-35 [kw] Heating 20-34 [kw] 1 1 General

More information

B1HQ SERIES - 14 SEER SINGLE PACKAGED HEAT PUMPS (R-410A, STYLE A,B)

B1HQ SERIES - 14 SEER SINGLE PACKAGED HEAT PUMPS (R-410A, STYLE A,B) www.source1parts.com HVAC SERVICE PARTS B1HQ SERIES - 14 SEER SINGLE PACKAGED HEAT PUMPS (R-410A, STYLE A,B) Supersedes:Nothing 035-23148-001 Rev. A (0212) 1 of 8 74 73 70 72 71 80 76 66 77 68 69 67 78

More information

CADB and CADT-D / DI / DC Series

CADB and CADT-D / DI / DC Series HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

CE8000 Energy Recovery Ventilator

CE8000 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 7000-8500 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel 18-gauge

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

Hotstore Stainless Steel Thermal Store Cylinder

Hotstore Stainless Steel Thermal Store Cylinder Hotstore Stainless Steel Thermal Store Cylinder Installation Guidance and Operating Instructions L318 General: These instructions must be read before undertaking installation or maintenance of Hotstore

More information

Efficient Cooling and Heating. Flexibility Is The Key

Efficient Cooling and Heating. Flexibility Is The Key Lynx Energy efficient fan coil unit Chilled water cooling & hot water heating Waterside control with variable air volume Commercially quiet with excellent acoustics Programmable communication control systems

More information

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

Under sill units. Type FSL-B-ZAS

Under sill units. Type FSL-B-ZAS .1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract

More information

Industrial Dryer Oven

Industrial Dryer Oven Industrial Dryer Oven W/I Style Industrial Dryer Oven ELECTRIC - TOP HEAT CHAMBER GAS - REAR HEAT CHAMBER UL LISTED CONTROL PANEL Standard W/I Ovens to meet the requirements of National Fire Protection

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS. DESCRIPTION FEATURES

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS.   DESCRIPTION FEATURES TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable

More information

squrboxbox heat recovery squrboxbox I technical information

squrboxbox heat recovery squrboxbox I technical information heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution

More information

FBM RANGE. Fitting Instructions and User Guide

FBM RANGE. Fitting Instructions and User Guide FBM RANGE Fitting Instructions and User Guide 1 NOTICE TO INSTALLER These water heater have a built in cold water feed cistern and float valve and can supply a number of hot water outlets. As the hot water

More information

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

CEILING CASSETTE FAN COIL UNIT

CEILING CASSETTE FAN COIL UNIT CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

WALL MOUNTED PACKAGE AIR CONDITIONER

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA, W8A, WA General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists of

More information

Ice Machine Parts List for Series S1600 Models

Ice Machine Parts List for Series S1600 Models SR600A SR60W SR690N SD60A SD603W Ice Machine Parts List for Series S600 Models SD69N SY60A SY60W SY69N S600 Rev 0/0 S600 CONTROL BOX 6 3 7 0 PT3 Control Board (for use with all voltages)...............................................

More information

Zone Valves and Parts (Honeywell)

Zone Valves and Parts (Honeywell) 28/11/14 B49 Zone Valves - Two Way Fan Coil Zone Valves and Parts (Honeywell) Two-way Fan Coil Valve, the VU53 high pressure zone valves are used to control the flow of hot or chilled water in commercial

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

SECTION ROOFTOP HEATING AND COOLING UNITS

SECTION ROOFTOP HEATING AND COOLING UNITS SECTION 15782 PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work

More information

Name: MUB E4 SILEO MULTIBOX Item no.: Version: 50 Hz; 90 airflow

Name: MUB E4 SILEO MULTIBOX Item no.: Version: 50 Hz; 90 airflow MUB 042 500E4 SILEO MULTIBOX Item no. 37901 Document type: Product card Document date: 2016-03-17 Generated by: Systemair Online Catalogue Version: 50 Hz; 90 airflow Description Speed-controllable Modular

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

APPLICATIONS Office Buildings Schools Hospitals Industrial Facilities Hotels A LONG LASTING, TROUBLE-FREE WATER HEATER

APPLICATIONS Office Buildings Schools Hospitals Industrial Facilities Hotels A LONG LASTING, TROUBLE-FREE WATER HEATER 6-120 GALLON CAPACITY, THREE PHASE VOLTAGES UP TO 58 KW, SINGLE PHASE VOLTAGES OVER 6KW Model SE FEATURES Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon alloy

More information

Kälte Klima. Condenserless chillers for indoor installation from 45 kw to 360 kw. Scroll compressors SCLY DE 48

Kälte Klima. Condenserless chillers for indoor installation from 45 kw to 360 kw. Scroll compressors SCLY DE 48 Condenserless chillers for indoor installation from 45 kw to 360 kw Scroll compressors Series: SCLY Leaflet: DE 48 Issue: 03/12 Supersedes: 04/11 Index Identification code Index... pag. 2 Identification

More information

HORIZONTAL AND VERTICAL FAN COIL UNITS

HORIZONTAL AND VERTICAL FAN COIL UNITS Bulletin 6L 1/14 HORIZONTAL AND VERTICAL FAN COIL UNITS P.O. Box 578 Devault, PA 19432 1-800-USA-COIL (1-800-872-2645) FAX: (610)-296-9763 www.usacoil.com Air Handling Units: Fast Shipment, excellent quality,

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

Installation and Servicing Instructions

Installation and Servicing Instructions Installation and Servicing Instructions Alpha Plus Units for Domestic Hot water and Low Pressure or Direct For Technical help or for Service call... ALPHA HELPLINE Tel: 0844 8718764 website:www.alpha-innovation.co.uk

More information

Commercial Electric Water Heater

Commercial Electric Water Heater MODEL SE Commercial Electric Water Heater 6-120 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction Hydrastone cement lining

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data C e i l i n g s u s p e n d e d u n i t E E D E N 2-0 0 FHQ-B8 Indoor Unit Ceiling suspended unit FHQ-B8 TABLE OF CONTENTS FHQ-B8 Features.............................................................

More information

ErP POWERBOX GF FANS - ESTOC TARGE FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

ErP POWERBOX GF FANS - ESTOC TARGE FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR 129 POWERBOX GF FANS - ESTOC TARGE FEATURES Sizes from 355 to 63 mm diameter Air flow up to 4. m 3 /s Static pressures up to 13 Pa Adjustable controllable external rotor motors Multiple outlet orientations

More information

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water 2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

ILLUSTRATED PARTS LIST XTREME ICE MAKER (1230 SERIES) MODEL NO.

ILLUSTRATED PARTS LIST XTREME ICE MAKER (1230 SERIES) MODEL NO. XTREME ICE MAKER (0 SERIES) MODEL NO. 00 00 00 00 00 00 0 XTREME ICE MAKER (0 SERIES) FIGURE. GENERAL ASSEMBLY (AIR CONDENSER SHOWN) 00 Screw TC - HXWS 00000 Screw TC - HXWS 0 (Marine) 0000 Grommet Nut

More information

Manitowoc. Ice Machine Parts List for Series S1400 Models SD1402A SD1403W SD1492N SY1404A SY1405W SY1494N JC1395 S

Manitowoc. Ice Machine Parts List for Series S1400 Models SD1402A SD1403W SD1492N SY1404A SY1405W SY1494N JC1395 S Manitowoc SD02A SD03W SD2N Ice Machine Parts List for Series S00 Models SY0A SY0W SYN JC3 S00 Updated: 3/2 S00 CONTROL BOX 2 2 6 3 0 PT3 Control Board (for use with all voltages)...............................................

More information

Manitowoc. Ice Machine Parts List for Series QDUALC Models QRDUALC QDDUALC QYDUALC CVD1875 CVD2075 QDUALC 1. Updated: 1/12

Manitowoc. Ice Machine Parts List for Series QDUALC Models QRDUALC QDDUALC QYDUALC CVD1875 CVD2075 QDUALC 1. Updated: 1/12 Manitowoc QRDUALC QDDUALC QYDUALC Ice Machine Parts List for Series QDUALC Models CVD CVD0 QDUALC Updated: / QDUALC CONTROL BOX 0, Control Board (for use with all voltages)...............................................

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install

More information

For Models HL, VF and VH Fan Coil Units

For Models HL, VF and VH Fan Coil Units For Models HL, VF and VH Fan Coil Units CONTENTS FCU CONTROL APPS. SELECTION GUIDE Instructions Single Point Power........................................................ 4 Electric Heat............................................................

More information

Valance. Independent Drain Pan. Architectural Enclosure

Valance. Independent Drain Pan. Architectural Enclosure Valance WHAT IS A VALANCE UNIT? Valance heating and cooling units utilize hydronic coils mounted in an architectural enclosure. The units are mounted near the ceiling usually along an outside wall. The

More information

PACKAGE AIR CONDITIONERS REPLACEMENT PARTS MANUAL

PACKAGE AIR CONDITIONERS REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL PACKAGE AIR CONDITIONERS Models: P1142A3 P1148A1 P1148A1-B P1148A1-C P1060A1 P1060A1-B P1060A1-C P1148A1-A/H P1148A1-B/H P1148A1-C/H P1060A1-A/H P1060A1-B/H P106A1-C/H General

More information

FORM NO. H REV. 6 Supersedes Form No. H Rev. 5 AIR HANDLERS

FORM NO. H REV. 6 Supersedes Form No. H Rev. 5 AIR HANDLERS FORM NO. H11-515 REV. 6 Supersedes Form No. H11-515 Rev. 5 AIR HANDLERS Features 11/2 ton [5.3 kw] through 5 ton [17.6 kw] models with Multiflex coils are always just 35 inches [889 mm] tall and 22 inches

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information