MAXI PUMPS 63

Size: px
Start display at page:

Download "MAXI PUMPS 63"

Transcription

1 MAXI PUMPS Cool running clean compact size easy to install environment-friendly PIAB Vacuum Pumps. 62

2 MAXI PUMPS 63

3 MAXI PUMPS MLL - Maxi Pump Aluminum body Noise level db(a) Largest compressed air driven pump on the market, yet comparatively compact and lightweight. Energy Saving (ES) system available. Max. Vacuum Pump Model Vacuum Flow in scfm at different vacuum level (-inhg) at 87 psi (-inhg) PIAB MLL 200/ES MLL 400/ES MLL 800/ES MLL 1200/ES Max. Vacuum Pump model Air Cons. Evacuation time in s/cubic foot to reach different vacuum levels (-inhg) (-inhg) PIAB- (scfm) MLL 200/ES MLL 400/ES MLL 800/ES MLL 1200/ES * For values of vacuum flow and evacuation time at other feed pressures, please see pages CHARACTERISTICS inhg at 87 psi Part Optimum Maximum Weight Sound Number for Pressure Vacuum Temperature lb. Level Material Ordering psi at 87 psi db(a) MLL U inhg -4 to +176 F PPS, aluminum, MLL200ES U inhg -4 to +176 F PPS, aluminum, MLL U inhg -4 to +176 F PPS, aluminum, MLL400ES U inhg -4 to +176 F PPS, aluminum, MLL U inhg -4 to +176 F PPS, aluminum, MLL800ES U inhg -4 to +176 F PPS, aluminum, MLL U inhg -4 to +176 F PPS, aluminum, MLL1200ES U inhg -4 to +176 F PPS, aluminum, * Viton or EPDM optional (i.e. Part No V or E). 64

4 B A CONNECTION SIZES Pump Compressed Air (1) Vacuum (2) Exhaust (3) MLL ID /G 3/ ID/1 1/2 NPT 1.57 ID/Vent MLL ID /G 3/ ID/1 1/2 NPT 2.36 ID/Vent MLL ID /G 3/ ID/2 NPT 2.96 ID/Vent MLL ID /G 3/ ID/2 NPT 3.94 ID/Vent MAXI PUMPS ES ONLY Pump A B C D E F G H I MLL200/ (6.10") 150 (5.91") 50 (1.97") Ø1/2" D=12 M5(8X) Ø90 (3.54") Ø110 (4.33") 67 (2.64") MLL (12.09") 85 (3.35") 55 (2.17") - - M6(8X) Ø140 (5.51") Ø160 (6.30") 72 (2.83") MLL (16.02") 85 (3.35") 55 (2.17") - - ØM6(8X) Ø140 (5.51") Ø160 (6.30") 72 (2.83") ACCESSORIES PSF 1.5 D E C MLL 200/400/800/1200 Recommended Vacuum Filter Filter Assembly Connection Replacement Replacement Part Number Port (NPT) Element Number Element Packed PPSF1.5-X75 1 1/2" PPX75RE3 3 PSF /2" PSF1.5RE 1 PSF2.0 2" PSF2.0RE 1 F G H MLL 200/400/800/1200ES ID size is minimum recommended hose size. G/NPT is shown in actual thread sizes. MLL Pump Seal Kits Nitrile Viton EPDM MLL V E MLL V E MLL V E ENERGY SAVING SYSTEM The PIAB energy saving (ES) system operates on a roughly similar system to that of a thermostat in a heating system. The energy saving achieved by the ES system will be at maximum if the vacuum system is sealed. The ES system is available installed on the ES versions of the MLL Vacuum Pump. B A ➃ Vacuum level adjustment Kits include flap valves, gaskets, and compressed air filters. D E Non-return valve (page 66) I 65

5 MAXI PUMPS ACCESSORIES FOR PUMP MODEL MAXI MLL Exhaust Adapter Central Exhaust is used when a external silencer is desired or if a tube/hose is going to be connected for removing the exhaust. Non return valve for MLL Ø55(8x) (0.22") Ø110 (4.33") Ø124 (4.88") Non return valve for MLL Ø65(8x) (0.26") Ø160 (6.30") Ø174 (6.85") Exhaust Adapter for MLL 15 (0.59") 15 Non return valve External non return valves are made of corrosion resistant material. Technical Data & Part Numbers Type Fits Material Weight Part No. Pump Size oz. Exhaust Adapter 148 MLL Al Exhaust Adapter 300 MLL800 Al Exhaust Adapter 400 MLL1200 Al Non return valve MLL Al, NBR Non return valve MLL Al, NBR (0.59") Part No. L A For Vacuum Pump mm [in] [5.83] MLL 200, MLL [11.80] MLL [15.80] 200 [7.87] MLL (6.06") 45 (1.77") 41.5 (1.63" Ø75 (2.95") 83 (3.27") 66

6 From the PIAB Vacuum Academy How do I turn on/off an MLL Maxi Vacuum Pump using the two remote connection ports? MAXI PUMPS It is easy to control any PIAB pump on/off with an air valve. The amount of compressed air pressure, usually measured in pounds per square inch (psi), determines the amount of vacuum pressure you can achieve from the PIAB Vacuum Pump. Bring compressed air to the MLL Maxi Pump via the main G 3/4" air connection port. This air generates the vacuum pressure and operates the internal valve of the pump. The MLL Maxi Pump has two remote connection ports on its face, labeled (1) and (2). Using a separate 3-way air valve, connect to the remote connection ports as shown on the diagram. Use a signal from the air valve to now start operation of the vacuum pump. Note:The on/off knob on the pump should be in the off position (pushed out). 3-WAY VALVE SIGNAL TO START PUMP 67

NITROUS TRANSFER PUMP INSTRUCTIONS

NITROUS TRANSFER PUMP INSTRUCTIONS NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.

More information

KNC Model 3666 Automatic Pressure Calibration System

KNC Model 3666 Automatic Pressure Calibration System KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory

More information

HYDROSTATIC TEST PUMPS

HYDROSTATIC TEST PUMPS HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy

More information

MEMBRANE VACUUM MINI PUMPS

MEMBRANE VACUUM MINI PUMPS MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The

More information

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC RECOVERY SUPEREVAC 29 RECOVERY 1/4" 4-IN-1 BALL VALVE TOOL For vacuum, charge, cores and recovery 18997 18975 18971 18978 18979 Remove and replace Schrader cores without losing charge. Extra 1/4" side

More information

YELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail

YELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail YELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail NEW Valve core tool page 35 EXPANDED LINE Quick couplers page 36 33 1/4" 4-IN-1 BALL VALVE TOOL for vacuum, charge, cores and recovery

More information

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

Air/Vacuum Valves. Removal of Air from Pipelines. Allow the Entry of Air into Pipelines. Application:

Air/Vacuum Valves. Removal of Air from Pipelines. Allow the Entry of Air into Pipelines. Application: /Vacuum Valves Micro-Irrigation and vacuum control is essential to the safety, longevity, efficiency, and performance of an irrigation system. must be allowed to exit pipelines 1) upon startup to prevent

More information

ASTM D 2000 - M 5BG 407 A14 B14 E014 E034 F17

ASTM D 2000 - M 5BG 407 A14 B14 E014 E034 F17 Understanding an ASTM D 2000 Call Out The ASTM D 2000 classification provides a system to standardize the properties of rubber materials. This classification was originally developed for use in the automotive

More information

SHOWERS 85-100 SHOWERS

SHOWERS 85-100 SHOWERS SHOWERS 85-100 85 SHOWERS SHOWER HEADS 87 NEPTUNE 89 SHOWER PANEL SERIES PERFECT TIME SHOWER PANEL SERIES 91 NEPTUNE 1042T 93 PERFECT TIME 1042T 94 NEPTUNE MEDICAL 95 TOUCH SH 1000T 96 NEPTUNE 1032 97

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

Spare Parts Program. Parts, Consumables & Accessories. 800.837.9711 superproductsllc.com

Spare Parts Program. Parts, Consumables & Accessories. 800.837.9711 superproductsllc.com Spare Parts Program Parts, Consumables & Accessories TABLE OF CONTENTS Program Introduction 3 Body 4 5 Boom 5 6 Hydraulic 6 Lights & Accessories 7 Tubes, Nozzles & Hose Fittings 8 11 Vacuum 11 Water 12

More information

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY

More information

NORMAN FILTER COMPANY PRODUCT OVERVIEW

NORMAN FILTER COMPANY PRODUCT OVERVIEW NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100

More information

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves 2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating

More information

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features P3000 Series Pneumatic Deadweight Testers P3000 Technical Data Features Pressure ranges from Vacuum through 2 000 psi (140 bar) Accuracy better than 0.015 % of reading. (Increased accuracy option of 0.008

More information

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special

More information

GRUNDFOS COMMERCIAL BUILDINGS

GRUNDFOS COMMERCIAL BUILDINGS GRUNDFOS COMMERCIAL BUILDINGS Grundfos provides a full range of gasketed and brazed plate heat exchangers designed for heating, ventilation, air-conditioning and cooling applications. BRAZED PLATE HEAT

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

NDP-50 Specifications

NDP-50 Specifications NDP-50 Specifications Port Dimensions Intake & discharge connection: (164 GPM Max.) Polypropylene (PPG) 2" ANSI B16.5 #150 Kynar (PVDF) 2" ANSI B16.5 #150 Aluminum (ADC-12) 2" ANSI B16.5 #150 (with tapped

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

AIR LINE VALVES AND GAUGES

AIR LINE VALVES AND GAUGES AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand

More information

Scotch-Weld PUR Easy 250 Adhesive Applicator

Scotch-Weld PUR Easy 250 Adhesive Applicator Scotch-Weld September, 2014 Product Description PUR Easy 250 Applicator is a self contained pneumatic applicator designed to dispense 1/10 th gallon(300ml) cartridges of 3M PUR adhesives. PURs are a family

More information

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4

More information

Typical Aluminum GFM Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.

More information

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves

More information

TTC-IIS Series Up to 11 LPM Free Flow

TTC-IIS Series Up to 11 LPM Free Flow 66 Up to 11 LPM Free Flow Typical Applications Gas Analysis Anesthesia Monitors CO 2 Monitors Patient Monitoring Wound Therapy Urinalysis Trace Detection Medical/Training Mannequins Degassing Product Specifications

More information

Type Function Namur Port size Max. air flow Operating pressure Weight

Type Function Namur Port size Max. air flow Operating pressure Weight DRN 3 601/DRN PN 5313 701/PN 611 /DRN 5313 121 128 2.8.4.1.1 2.8.2.3 Seite page oldal 161 PNDRN 531 701 3 601 PNDRN 531 121 3 611 DRN 3 128 PN 531 701 DRN 3 601 BlockPneumatikus form flow regulator vezérlésű

More information

Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam.

Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam. M3 Plate heat exchanger Applications General heating and cooling duties. Heating by means of steam. Standard design The plate heat exchanger consists of a pack of corrugated metal plates with portholes

More information

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

Baumann 24003 3 Way Bronze or Stainless Steel Control Valve

Baumann 24003 3 Way Bronze or Stainless Steel Control Valve Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

OEM-EP Pressure Controllers

OEM-EP Pressure Controllers Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable

More information

WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS

WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS BAT Inc. 7630 Matoaka Road., Sarasota, FL. 34243 (941) 355-0005 fax (941) 355-4683 Heavy Duty Oil Scavenge/Circulation Pump When high temperature and continuous

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009 Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25

More information

Vision Engravers and Routers PRE-Installation Guide. 2015 Vision Engraving & Routing Systems

Vision Engravers and Routers PRE-Installation Guide. 2015 Vision Engraving & Routing Systems Vision Engravers and Routers PRE-Installation Guide Revised: 8/19/2015 Vision Engravers and Routers PRE-Installation Guide All rights reserved. No parts of this work may be reproduced in any form or by

More information

Stainless Steel Valves For the Sanitary Industries

Stainless Steel Valves For the Sanitary Industries www.swagelok.com Stainless Steel Valves For the Sanitary Industries Sanitary ball valves Manual and pneumatically actuated butterfly valves Disk and ball check valves ir blow check valves ir relief valves

More information

TRANSLATION OF THE ORIGINAL MANUAL

TRANSLATION OF THE ORIGINAL MANUAL l FLOWMAX PUMPS 08-120 F / 08-120 FT 16-120 F / 16-120 FT TECHNICAL FEATURES TRANSLATION OF THE ORIGINAL MANUAL IMPORTANT : Before assembly and start-up, please read and clearly understand all the documents

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

167D Series Switching Valves

167D Series Switching Valves June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are

More information

CAT. 0113-GB MODELS. Series. Flat-face quick-release couplings. UNI EN ISO 9001 Cert. n 2905 ISO/TS 16949

CAT. 0113-GB MODELS. Series. Flat-face quick-release couplings. UNI EN ISO 9001 Cert. n 2905 ISO/TS 16949 CAT. 0113-GB NEW MODELS Flat-face quick-release couplings UNI EN ISO 9001 Cert. n 2905 ISO/TS 16949 FLAT-FACE QUICK-RELEASE COUPLINGS Features Benefits Applications Flat-face shut-off valves: easy to clean.

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

Control blocks for two-hand start ZSB

Control blocks for two-hand start ZSB Key features Function This pneumatic control block for twohand start ZSB is used where a manually started operation, such as the triggering of compressed air cylinders, would otherwise involve danger for

More information

PC1131 Electric Air Compressor

PC1131 Electric Air Compressor Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

Check Valves & Actuated Valves

Check Valves & Actuated Valves heck Valves & ctuated Valves & U Series Piston non-return valves rated 6,000 psi & 10,000 psi X Series Piston non-return valves rated 20,000 psi Pneumatic ctuators Pneumatically actuated valves Electric

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

stainless steel pre-assembled manifolds

stainless steel pre-assembled manifolds TECHNICAL CATALOGUE stainless steel pre-assembled manifolds TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and

More information

Used Fluid Handling Portable Used-Oil Gravity Drains

Used Fluid Handling Portable Used-Oil Gravity Drains Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)

More information

Process Equipment Catalog Pumping Solutions for Process Industries

Process Equipment Catalog Pumping Solutions for Process Industries Process Equipment Catalog Pumping Solutions for Process Industries Proven Quality. Leading Technology. Table of Contents Process Equipment Buyer s Guide Contents Air-Operated Double Diaphragm Pumps Model

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com. Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

PC1130 Electric Air Compressor

PC1130 Electric Air Compressor Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in

More information

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVI is self-acting thermostatic actuator primarily for use for temperature control

More information

MOLECULAR DRAG PUMPS MDP SERIES

MOLECULAR DRAG PUMPS MDP SERIES MOLECULAR DRAG PUMPS MDP SERIES MOLECULAR DRAG PUMPS MDP SERIES If you need: to replace a rotary vane pump with a dry pump for an application at 10-3 a turbopump that can operate up to 10 a pump that can

More information

Itho Products for Hot and Boiling water. product-

Itho Products for Hot and Boiling water. product- Itho Products for Hot and Boiling water product- 2 This booklet provides additional information on the range of hot and boiling water appliances by Itho. The data will allow you to determine which product

More information

ROTARY SCREW COMPRESSOR. RMD 30-37 - 45-55 kw

ROTARY SCREW COMPRESSOR. RMD 30-37 - 45-55 kw ROTARY SCREW COMPRESSOR RMD - - - 55 kw EN The RMD Coaxial Rotary Compressor high reliability high performance low maintenance is the result of decades of experience in manufacturing design and construction

More information

NUMBER: 08 DD15-10 S.M. REF.: 3.2 ENGINE: DD15 DATE: September 2008

NUMBER: 08 DD15-10 S.M. REF.: 3.2 ENGINE: DD15 DATE: September 2008 NUMBER: 08 DD15-10 S.M. REF.: 3.2 ENGINE: DD15 DATE: September 2008 SUBJECT: 3.2 OIL PAN PUBLICATION: DDC-SVC-MAN-0002 Oil pan section 3.2 has been updated. Section Change 3.2 Oil Pan Call-outs have been

More information

ZA-12. Temperature - Liquidus + 45 o C (81 o C) Vacuum = 90mm

ZA-12. Temperature - Liquidus + 45 o C (81 o C) Vacuum = 90mm Ragonne Fluidity, Inches Zn-Al Impact 38 34 30 26 22 18 14 No. 3 Zn-Al ZA-8 Liquidius ZA-12 Temperature - Liquidus + 45 o C (81 o C) Vacuum = 90mm Zn-Al (0.01-0.02 percent mg) ZA-27 10 0 2 4 6 8 10 12

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

ABEL EM. Electromechanical. Membrane Pumps. The economical alternative. From the reciprocating positive displacement pump specialist

ABEL EM. Electromechanical. Membrane Pumps. The economical alternative. From the reciprocating positive displacement pump specialist ABEL EM From the reciprocating positive displacement pump specialist Electromechanical Membrane Pumps. The economical alternative. 3 Membrane Pumps Solids Handling Pumps High Pressure Pumps Marine Pumps

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Overheating limit control

Overheating limit control Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating

More information

TECHNICAL BULLETIN. Kämmer LinedFlow - 132000 Corrosive Application Valves. Experience In Motion FCD KMENTB3221-01 04/12

TECHNICAL BULLETIN. Kämmer LinedFlow - 132000 Corrosive Application Valves. Experience In Motion FCD KMENTB3221-01 04/12 TECHNICAL BULLETIN Kämmer LinedFlow - 132000 Corrosive Application Valves FCD KMENTB3221-01 04/12 Experience In Motion Description ¼-inch NPT test port Large guided stem area Bellows seal eliminates stem

More information

Water Pump Replacement

Water Pump Replacement 1 of 8 2/5/2008 6:36 AM Document ID# 713637 2001 Cadillac Seville Print Water Pump Replacement Tools Required 1. J 38816-A Water Pump Remover & Installer 2. J 38185 Hose Clamp Pliers

More information

LOBOY 16 AIR CONDITIONERS

LOBOY 16 AIR CONDITIONERS INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com

More information

Excellence through Versatility

Excellence through Versatility Metering Pumps Excellence through Versatility Liquid Metronics Incorporated has been providing quality products and service to the water treatment industry worldwide for over 25 years. Leading the way

More information

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Shut-off & Lockout Valves 1/4 to 1-1/2 port size Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Actuator-Swirl Valve DESCRIPTION

Actuator-Swirl Valve DESCRIPTION US/Canadian 2007 Sprinter Diesel V6 Dodge Service Manual Swirl Valve Info Actuator-Swirl Valve DESCRIPTION The swirl valve linkage links the swirl valves in the intake manifold to the swirl valve actuator.

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves Features Top guided design offers high capacity with 0.110 in 2 [0.710 cm 2 ] orifice area.

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6. TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM

More information

ENGINE COOLING SYSTEM

ENGINE COOLING SYSTEM ENGINE COOLING SYSTEM 1988 Toyota Celica 1987-88 TOYOTA Engine Cooling Systems Celica DESCRIPTION The basic liquid cooling system consists of a radiator, water pump, thermostat, cooling fan, pressure cap,

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information

SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL

SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.

More information

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to

More information

15/40/80CN Series Coreless Medium Pressure Filters

15/40/80CN Series Coreless Medium Pressure Filters //8CN Series Coreless Medium Pressure Filters //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment Pilot

More information

ThermoSorb Desiccant Dryers

ThermoSorb Desiccant Dryers ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression

More information

Laboratory & Scientific Line. Horizontal Steam Sterilizers

Laboratory & Scientific Line. Horizontal Steam Sterilizers Laboratory & Scientific Line Horizontal Steam Sterilizers Horizontal Steam Sterilizers for Laboratory & Scientific Applications Sterilization in a laboratory environment has its unique requirements. The

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

BASIS RANGE TMB SERIES

BASIS RANGE TMB SERIES BASIS RANGE SERIES magnetic driven pumps BASIS The pumps belong to Argal s BASIS range and feature, single stage, centrifugal impeller and magnetic drive. The range of pumps includes five models to deliver

More information

Model 4418F. www.amot.com. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Model 4418F. www.amot.com. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve High Pressure Control Valve Model 4418F Overview The 4418F has been designed specifically for use as an air start valve for diesel engines or as a fuel shut-off valve for gas turbine applications. Its

More information