MAXI PUMPS 63
|
|
- Scot Lee
- 7 years ago
- Views:
Transcription
1 MAXI PUMPS Cool running clean compact size easy to install environment-friendly PIAB Vacuum Pumps. 62
2 MAXI PUMPS 63
3 MAXI PUMPS MLL - Maxi Pump Aluminum body Noise level db(a) Largest compressed air driven pump on the market, yet comparatively compact and lightweight. Energy Saving (ES) system available. Max. Vacuum Pump Model Vacuum Flow in scfm at different vacuum level (-inhg) at 87 psi (-inhg) PIAB MLL 200/ES MLL 400/ES MLL 800/ES MLL 1200/ES Max. Vacuum Pump model Air Cons. Evacuation time in s/cubic foot to reach different vacuum levels (-inhg) (-inhg) PIAB- (scfm) MLL 200/ES MLL 400/ES MLL 800/ES MLL 1200/ES * For values of vacuum flow and evacuation time at other feed pressures, please see pages CHARACTERISTICS inhg at 87 psi Part Optimum Maximum Weight Sound Number for Pressure Vacuum Temperature lb. Level Material Ordering psi at 87 psi db(a) MLL U inhg -4 to +176 F PPS, aluminum, MLL200ES U inhg -4 to +176 F PPS, aluminum, MLL U inhg -4 to +176 F PPS, aluminum, MLL400ES U inhg -4 to +176 F PPS, aluminum, MLL U inhg -4 to +176 F PPS, aluminum, MLL800ES U inhg -4 to +176 F PPS, aluminum, MLL U inhg -4 to +176 F PPS, aluminum, MLL1200ES U inhg -4 to +176 F PPS, aluminum, * Viton or EPDM optional (i.e. Part No V or E). 64
4 B A CONNECTION SIZES Pump Compressed Air (1) Vacuum (2) Exhaust (3) MLL ID /G 3/ ID/1 1/2 NPT 1.57 ID/Vent MLL ID /G 3/ ID/1 1/2 NPT 2.36 ID/Vent MLL ID /G 3/ ID/2 NPT 2.96 ID/Vent MLL ID /G 3/ ID/2 NPT 3.94 ID/Vent MAXI PUMPS ES ONLY Pump A B C D E F G H I MLL200/ (6.10") 150 (5.91") 50 (1.97") Ø1/2" D=12 M5(8X) Ø90 (3.54") Ø110 (4.33") 67 (2.64") MLL (12.09") 85 (3.35") 55 (2.17") - - M6(8X) Ø140 (5.51") Ø160 (6.30") 72 (2.83") MLL (16.02") 85 (3.35") 55 (2.17") - - ØM6(8X) Ø140 (5.51") Ø160 (6.30") 72 (2.83") ACCESSORIES PSF 1.5 D E C MLL 200/400/800/1200 Recommended Vacuum Filter Filter Assembly Connection Replacement Replacement Part Number Port (NPT) Element Number Element Packed PPSF1.5-X75 1 1/2" PPX75RE3 3 PSF /2" PSF1.5RE 1 PSF2.0 2" PSF2.0RE 1 F G H MLL 200/400/800/1200ES ID size is minimum recommended hose size. G/NPT is shown in actual thread sizes. MLL Pump Seal Kits Nitrile Viton EPDM MLL V E MLL V E MLL V E ENERGY SAVING SYSTEM The PIAB energy saving (ES) system operates on a roughly similar system to that of a thermostat in a heating system. The energy saving achieved by the ES system will be at maximum if the vacuum system is sealed. The ES system is available installed on the ES versions of the MLL Vacuum Pump. B A ➃ Vacuum level adjustment Kits include flap valves, gaskets, and compressed air filters. D E Non-return valve (page 66) I 65
5 MAXI PUMPS ACCESSORIES FOR PUMP MODEL MAXI MLL Exhaust Adapter Central Exhaust is used when a external silencer is desired or if a tube/hose is going to be connected for removing the exhaust. Non return valve for MLL Ø55(8x) (0.22") Ø110 (4.33") Ø124 (4.88") Non return valve for MLL Ø65(8x) (0.26") Ø160 (6.30") Ø174 (6.85") Exhaust Adapter for MLL 15 (0.59") 15 Non return valve External non return valves are made of corrosion resistant material. Technical Data & Part Numbers Type Fits Material Weight Part No. Pump Size oz. Exhaust Adapter 148 MLL Al Exhaust Adapter 300 MLL800 Al Exhaust Adapter 400 MLL1200 Al Non return valve MLL Al, NBR Non return valve MLL Al, NBR (0.59") Part No. L A For Vacuum Pump mm [in] [5.83] MLL 200, MLL [11.80] MLL [15.80] 200 [7.87] MLL (6.06") 45 (1.77") 41.5 (1.63" Ø75 (2.95") 83 (3.27") 66
6 From the PIAB Vacuum Academy How do I turn on/off an MLL Maxi Vacuum Pump using the two remote connection ports? MAXI PUMPS It is easy to control any PIAB pump on/off with an air valve. The amount of compressed air pressure, usually measured in pounds per square inch (psi), determines the amount of vacuum pressure you can achieve from the PIAB Vacuum Pump. Bring compressed air to the MLL Maxi Pump via the main G 3/4" air connection port. This air generates the vacuum pressure and operates the internal valve of the pump. The MLL Maxi Pump has two remote connection ports on its face, labeled (1) and (2). Using a separate 3-way air valve, connect to the remote connection ports as shown on the diagram. Use a signal from the air valve to now start operation of the vacuum pump. Note:The on/off knob on the pump should be in the off position (pushed out). 3-WAY VALVE SIGNAL TO START PUMP 67
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
More informationKNC Model 3666 Automatic Pressure Calibration System
KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory
More informationHYDROSTATIC TEST PUMPS
HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy
More informationMEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
More informationThermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
More informationMACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC
RECOVERY SUPEREVAC 29 RECOVERY 1/4" 4-IN-1 BALL VALVE TOOL For vacuum, charge, cores and recovery 18997 18975 18971 18978 18979 Remove and replace Schrader cores without losing charge. Extra 1/4" side
More informationYELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail
YELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail NEW Valve core tool page 35 EXPANDED LINE Quick couplers page 36 33 1/4" 4-IN-1 BALL VALVE TOOL for vacuum, charge, cores and recovery
More informationWILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP
WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams
More information2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
More informationAir/Vacuum Valves. Removal of Air from Pipelines. Allow the Entry of Air into Pipelines. Application:
/Vacuum Valves Micro-Irrigation and vacuum control is essential to the safety, longevity, efficiency, and performance of an irrigation system. must be allowed to exit pipelines 1) upon startup to prevent
More informationASTM D 2000 - M 5BG 407 A14 B14 E014 E034 F17
Understanding an ASTM D 2000 Call Out The ASTM D 2000 classification provides a system to standardize the properties of rubber materials. This classification was originally developed for use in the automotive
More informationSHOWERS 85-100 SHOWERS
SHOWERS 85-100 85 SHOWERS SHOWER HEADS 87 NEPTUNE 89 SHOWER PANEL SERIES PERFECT TIME SHOWER PANEL SERIES 91 NEPTUNE 1042T 93 PERFECT TIME 1042T 94 NEPTUNE MEDICAL 95 TOUCH SH 1000T 96 NEPTUNE 1032 97
More information3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
More informationSpare Parts Program. Parts, Consumables & Accessories. 800.837.9711 superproductsllc.com
Spare Parts Program Parts, Consumables & Accessories TABLE OF CONTENTS Program Introduction 3 Body 4 5 Boom 5 6 Hydraulic 6 Lights & Accessories 7 Tubes, Nozzles & Hose Fittings 8 11 Vacuum 11 Water 12
More informationHOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS
HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY
More informationNORMAN FILTER COMPANY PRODUCT OVERVIEW
NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100
More informationball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves
2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating
More informationP3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features
P3000 Series Pneumatic Deadweight Testers P3000 Technical Data Features Pressure ranges from Vacuum through 2 000 psi (140 bar) Accuracy better than 0.015 % of reading. (Increased accuracy option of 0.008
More informationThermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special
More informationGRUNDFOS COMMERCIAL BUILDINGS
GRUNDFOS COMMERCIAL BUILDINGS Grundfos provides a full range of gasketed and brazed plate heat exchangers designed for heating, ventilation, air-conditioning and cooling applications. BRAZED PLATE HEAT
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationNDP-50 Specifications
NDP-50 Specifications Port Dimensions Intake & discharge connection: (164 GPM Max.) Polypropylene (PPG) 2" ANSI B16.5 #150 Kynar (PVDF) 2" ANSI B16.5 #150 Aluminum (ADC-12) 2" ANSI B16.5 #150 (with tapped
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationPowers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
More informationAIR LINE VALVES AND GAUGES
AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand
More informationScotch-Weld PUR Easy 250 Adhesive Applicator
Scotch-Weld September, 2014 Product Description PUR Easy 250 Applicator is a self contained pneumatic applicator designed to dispense 1/10 th gallon(300ml) cartridges of 3M PUR adhesives. PURs are a family
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
More informationTypical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
More informationThermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves
More informationTTC-IIS Series Up to 11 LPM Free Flow
66 Up to 11 LPM Free Flow Typical Applications Gas Analysis Anesthesia Monitors CO 2 Monitors Patient Monitoring Wound Therapy Urinalysis Trace Detection Medical/Training Mannequins Degassing Product Specifications
More informationType Function Namur Port size Max. air flow Operating pressure Weight
DRN 3 601/DRN PN 5313 701/PN 611 /DRN 5313 121 128 2.8.4.1.1 2.8.2.3 Seite page oldal 161 PNDRN 531 701 3 601 PNDRN 531 121 3 611 DRN 3 128 PN 531 701 DRN 3 601 BlockPneumatikus form flow regulator vezérlésű
More informationPlate heat exchanger. Applications General heating and cooling duties. Heating by means of steam.
M3 Plate heat exchanger Applications General heating and cooling duties. Heating by means of steam. Standard design The plate heat exchanger consists of a pack of corrugated metal plates with portholes
More informationThermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves
More information% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
More informationBaumann 24003 3 Way Bronze or Stainless Steel Control Valve
Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control
More informationStainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More informationOEM-EP Pressure Controllers
Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable
More informationWATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS
WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS BAT Inc. 7630 Matoaka Road., Sarasota, FL. 34243 (941) 355-0005 fax (941) 355-4683 Heavy Duty Oil Scavenge/Circulation Pump When high temperature and continuous
More informationPowers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat
Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual
More informationPrecision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.
Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009
Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25
More informationVision Engravers and Routers PRE-Installation Guide. 2015 Vision Engraving & Routing Systems
Vision Engravers and Routers PRE-Installation Guide Revised: 8/19/2015 Vision Engravers and Routers PRE-Installation Guide All rights reserved. No parts of this work may be reproduced in any form or by
More informationStainless Steel Valves For the Sanitary Industries
www.swagelok.com Stainless Steel Valves For the Sanitary Industries Sanitary ball valves Manual and pneumatically actuated butterfly valves Disk and ball check valves ir blow check valves ir relief valves
More informationTRANSLATION OF THE ORIGINAL MANUAL
l FLOWMAX PUMPS 08-120 F / 08-120 FT 16-120 F / 16-120 FT TECHNICAL FEATURES TRANSLATION OF THE ORIGINAL MANUAL IMPORTANT : Before assembly and start-up, please read and clearly understand all the documents
More informationMorrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
More informationEurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
More information167D Series Switching Valves
June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are
More informationCAT. 0113-GB MODELS. Series. Flat-face quick-release couplings. UNI EN ISO 9001 Cert. n 2905 ISO/TS 16949
CAT. 0113-GB NEW MODELS Flat-face quick-release couplings UNI EN ISO 9001 Cert. n 2905 ISO/TS 16949 FLAT-FACE QUICK-RELEASE COUPLINGS Features Benefits Applications Flat-face shut-off valves: easy to clean.
More information6 Crankcase Ventilation
6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................
More informationControl blocks for two-hand start ZSB
Key features Function This pneumatic control block for twohand start ZSB is used where a manually started operation, such as the triggering of compressed air cylinders, would otherwise involve danger for
More informationPC1131 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
More informationAIR-AIR PRESSURE MULTIPLIER (BOOSTER)
AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally
More information300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
More informationSunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
More informationPowers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
More informationCheck Valves & Actuated Valves
heck Valves & ctuated Valves & U Series Piston non-return valves rated 6,000 psi & 10,000 psi X Series Piston non-return valves rated 20,000 psi Pneumatic ctuators Pneumatically actuated valves Electric
More informationVC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge
More informationstainless steel pre-assembled manifolds
TECHNICAL CATALOGUE stainless steel pre-assembled manifolds TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and
More informationUsed Fluid Handling Portable Used-Oil Gravity Drains
Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)
More informationProcess Equipment Catalog Pumping Solutions for Process Industries
Process Equipment Catalog Pumping Solutions for Process Industries Proven Quality. Leading Technology. Table of Contents Process Equipment Buyer s Guide Contents Air-Operated Double Diaphragm Pumps Model
More informationMedical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
More informationInstruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.
Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without
More informationPC1130 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
More informationThermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVI is self-acting thermostatic actuator primarily for use for temperature control
More informationMOLECULAR DRAG PUMPS MDP SERIES
MOLECULAR DRAG PUMPS MDP SERIES MOLECULAR DRAG PUMPS MDP SERIES If you need: to replace a rotary vane pump with a dry pump for an application at 10-3 a turbopump that can operate up to 10 a pump that can
More informationItho Products for Hot and Boiling water. product-
Itho Products for Hot and Boiling water product- 2 This booklet provides additional information on the range of hot and boiling water appliances by Itho. The data will allow you to determine which product
More informationROTARY SCREW COMPRESSOR. RMD 30-37 - 45-55 kw
ROTARY SCREW COMPRESSOR RMD - - - 55 kw EN The RMD Coaxial Rotary Compressor high reliability high performance low maintenance is the result of decades of experience in manufacturing design and construction
More informationNUMBER: 08 DD15-10 S.M. REF.: 3.2 ENGINE: DD15 DATE: September 2008
NUMBER: 08 DD15-10 S.M. REF.: 3.2 ENGINE: DD15 DATE: September 2008 SUBJECT: 3.2 OIL PAN PUBLICATION: DDC-SVC-MAN-0002 Oil pan section 3.2 has been updated. Section Change 3.2 Oil Pan Call-outs have been
More informationZA-12. Temperature - Liquidus + 45 o C (81 o C) Vacuum = 90mm
Ragonne Fluidity, Inches Zn-Al Impact 38 34 30 26 22 18 14 No. 3 Zn-Al ZA-8 Liquidius ZA-12 Temperature - Liquidus + 45 o C (81 o C) Vacuum = 90mm Zn-Al (0.01-0.02 percent mg) ZA-27 10 0 2 4 6 8 10 12
More informationCartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)
Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers
More informationABEL EM. Electromechanical. Membrane Pumps. The economical alternative. From the reciprocating positive displacement pump specialist
ABEL EM From the reciprocating positive displacement pump specialist Electromechanical Membrane Pumps. The economical alternative. 3 Membrane Pumps Solids Handling Pumps High Pressure Pumps Marine Pumps
More informationSCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More informationOverheating limit control
Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating
More informationTECHNICAL BULLETIN. Kämmer LinedFlow - 132000 Corrosive Application Valves. Experience In Motion FCD KMENTB3221-01 04/12
TECHNICAL BULLETIN Kämmer LinedFlow - 132000 Corrosive Application Valves FCD KMENTB3221-01 04/12 Experience In Motion Description ¼-inch NPT test port Large guided stem area Bellows seal eliminates stem
More informationWater Pump Replacement
1 of 8 2/5/2008 6:36 AM Document ID# 713637 2001 Cadillac Seville Print Water Pump Replacement Tools Required 1. J 38816-A Water Pump Remover & Installer 2. J 38185 Hose Clamp Pliers
More informationLOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
More informationExcellence through Versatility
Metering Pumps Excellence through Versatility Liquid Metronics Incorporated has been providing quality products and service to the water treatment industry worldwide for over 25 years. Leading the way
More informationShut-off & Lockout Valves 1/4" to 1-1/2" port size
Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout
More informationSingle sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
More informationActuator-Swirl Valve DESCRIPTION
US/Canadian 2007 Sprinter Diesel V6 Dodge Service Manual Swirl Valve Info Actuator-Swirl Valve DESCRIPTION The swirl valve linkage links the swirl valves in the intake manifold to the swirl valve actuator.
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationHydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
More informationS GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR
MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,
More informationNon-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves
Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves Features Top guided design offers high capacity with 0.110 in 2 [0.710 cm 2 ] orifice area.
More informationCONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM
More informationENGINE COOLING SYSTEM
ENGINE COOLING SYSTEM 1988 Toyota Celica 1987-88 TOYOTA Engine Cooling Systems Celica DESCRIPTION The basic liquid cooling system consists of a radiator, water pump, thermostat, cooling fan, pressure cap,
More informationUnico Inverter. Unique and efficient.
Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed
More informationSIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL
SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.
More informationXE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY
XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to
More information15/40/80CN Series Coreless Medium Pressure Filters
//8CN Series Coreless Medium Pressure Filters //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment Pilot
More informationThermoSorb Desiccant Dryers
ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression
More informationLaboratory & Scientific Line. Horizontal Steam Sterilizers
Laboratory & Scientific Line Horizontal Steam Sterilizers Horizontal Steam Sterilizers for Laboratory & Scientific Applications Sterilization in a laboratory environment has its unique requirements. The
More informationHEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
More informationDIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
More informationScraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
More informationBASIS RANGE TMB SERIES
BASIS RANGE SERIES magnetic driven pumps BASIS The pumps belong to Argal s BASIS range and feature, single stage, centrifugal impeller and magnetic drive. The range of pumps includes five models to deliver
More informationModel 4418F. www.amot.com. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve
High Pressure Control Valve Model 4418F Overview The 4418F has been designed specifically for use as an air start valve for diesel engines or as a fuel shut-off valve for gas turbine applications. Its
More information