1 Want to know more? See our Metac video ISOVER Pitched Roof Solutions Insulation, Airtightness and Moisture Management Solutions for Timber Frame Roof Structures PART L TGD F1 Compliant
2 ISOVER Saint Gobain helping you create energy efficient buildings that provide a comfortable, healthy indoor environment using sustainable solutions. Pitched Roof Solutions
3 Pitched Roof Solutions 1 Pitched Roof Application ISOVER Metac and Vario System Great Performance Gentle To Use Good For Our Environment NEW GENERATION MINERAL WOOL INSULATION ISOVER offers one of the safest options for insulating Pitched Roofs both in New Build and Renovation. Metac is a high performance mineral wool insulation slab on a roll which when used with our Vario Airtightness and Moisture Control System offers one of the safest, and thermal and acoustic performing systems on the market. W/mK High Performance thermal insulation 0.034W/mK Excellent Acoustic Performance A1 Fire rating highest rating on the market BS EN No slump during installation and life of the system Friction fits in rafters eliminating any air gaps Vario XtraSafe membrane apply and release function for quick installation Vapour permeable insulation for maximum protection from moisture and condensation issues Metac Insulation can be full filled when used with our Vario system* Excellent Indoor Air Quality Eurofins Gold Comfort Made from Recycled materials up to 86% recycled glass G3 Touch technology, great performance, gentle to use, good for the environment * Please ensure installation is in accordance with roof slate/tile and roof membrane manufacturers guidelines. EN ISO WHERE TO USE 10+ YEARS Residential Non Residential New and Old
4 Pitched Roof Solutions 2 Building Regulations - Republic of Ireland NEW BUILD U VALUES: 0.16 PITCHED ROOF RENOVATION U VALUES: 0.25 PITCHED ROOF The following is a guide to thermal building regulations for new & existing dwellings - comfort and energy savings through effective thermal insulation. Republic of Ireland New Dwellings TGD - Part L Minimum standards for U-Values 0.16 (pitched roof ) 0.21 (walls) 0.16 (attics) 0.20 (fl at roofs) Upper limit for air permeability is 7m3/(h.m2) Average U-Value 1.60 (doors and window s) 0.21 (walls ) 0.21 (floors) 0.21(walls ) 0.21 (floors) For more information you can contact our technical team on free phone (ROI) or go to Republic of Ireland Existing Dwellings TGD - Part L (pitched roof ) (walls ) 0.16 (attics) 0.25 (flat roofs) Minimum standards for U-Values Average U-Value 1.60 (doors and window s) 0. 35/0.55 (walls ) 0.25 (floors) (walls ) (floor s) For more information you can contact our technical team on free phone (ROI) or go to
5 3 Building Regulations - Northern Ireland NEW BUILD U VALUES: 0.20 PITCHED ROOF RENOVATION U VALUES: 0.18 PITCHED ROOF The following is a guide to thermal building regulations for new & existing dwellings - comfort and energy savings through effective thermal insulation. Northern Ireland New Dwellings DFP Technical Booklet F1: (Roofs Pitched) 0.30 (Walls Internal/External Insulation) 0.20 (Roofs Attics) 0.20 (Roofs Flat) Minimum standards for U-Values Upper limit for air permeability is 10m3/(h.m2) Average 2.00 (Doors & Windows) 0.20 (Party Walls) 0.30 (Walls Cavity insulation) 0.30 ( Walls Internal/ External insulation) 0.25 (Floors) 0.30 (Walls Cavity insulation) 0.30 ( Walls Internal/External insulation) 0.25 (Floors) For more information you can contact our technical team on phone (NI) or go to Northern Ireland Existing Dwellings - DFP Technical Booklet F1: */ 0.18 (Roofs Pitched) 0.28*/ 0.30 (Walls Internal/External Insulation) 0.16*/ 0.16 (Roofs Attics) 0.18*/ 0.18 (Roofs Flat) Minimum standards for U-Values These regulations are split across new thermal elements added to an existing dwelling, for example a new extension or dormer & upgraded thermal elements within the existing building. Average 2.00 (Doors & Windows) 0.22*/ 0.25 (Floors) 0.28*/ 0.55 (Walls Cavity insulation) 0.28*/ 0.30 ( Walls Internal/ External insulation) 0.22*/ 0.25 (Floors) 0.28*/ 0.55 (Walls Cavity insulation) 0.28*/ 0.30 ( Walls Internal/External insulation) *figures refer to a new element added to an existing dwelling i.e. extension, dormer etc. For more information you can contact our technical team on phone (NI) or go to Pitched Roof Solutions
6 Pitched Roof Solutions 4 Standards and Certification A SELF-SUPPORTING SLAB ON A ROLL IDEAL FOR VERTICAL AND PITCHED APPLICATIONS NO SLUMP DURING INSTALLATION AND LIFE OF THE SYSTEM BREATHABILITY-VARIO MEMBRANE FOR MAXIMUM PROTECTION FROM MOISTURE QUALITY We hold a Quality Management Standard BS EN ISO 9001: 2008 for manufacturing. CE All products are manufactured in accordance with the CE marking requirements under the Construction Products Regulation. PRODUCT STANDARDS All our products are manufactured in accordance with product standard: BS EN 13162: 2008 and BS EN Evaluation of Conformity. BS EN ISO 9001: 2000 ENVIRONMENT INDOOR AIR QUALITY DURABILITY I SOVER is an ISO 14001:2004 (Environmental Management System) accredited manufacturing facility. This accreditation ensures that all products are manufactured to the stringent standards set out by this management system. EN ISO EMS BS EN ISO 9001: Awarded the highest standard in indoor air quality - Eurofins Gold Label The Gold Certificate means that ISOVER mineral wool is certified as an outstanding material in terms of Indoor Air Quality emissions regulations. Fire Performance Euroclass classification of the product is related to the organic content, which cannot increase with time. Thermal conductivity of mineral wool products does not change with time, experience has shown the fibre structure to be stable and the porosity contains no other gases than atmospheric air. (See std EN13162:2012 Annex ZA,Table ZA.1) Will not accelerate corrosion with steel, copper or aluminium. Will not sustain vermin, nor breed or promote fungi or bacteria. EN ISO EMS
7 Control of Condensation and Ventilation ISOVER complies with BS 5250:2011 Code of practice for control of condensation in buildings & ICP 2:2002 Irish Standard for Tiled and Slated Roof Constructions. These are the industry standards to ensure the building fabric is protected from moisture and condensation damage by ensuring adequate vapour control and ventilation measures are installed. The standards cover: Dealing with high moisture levels and condensation to protecting the building fabric. Addressing the risks associated with excessive humidity in buildings, notably mould growth and condensation. Ensuring a sufficiently permeable roof build up i.e. use of an adequate breathable roofing felt in conjunction with an air-open roof covering (e.g. natural slates or concrete tiles not fibre cement). Recommending Best Practice construction, counter-battens above the roof membrane allows for better drainage rain water and can accommodate ventilation under non-air open coverings where ridge and eaves vents are provided over the felt. ISOVER Pitched Roof Solutions - How do they comply with these industry standards? Protecting Building Fabric - Managing moisture vapour Healthy Indoor Air Quality - dealing with mould growth and condensation Energy Savings - Creating an airtight construction Full ISOVER Solution: High performance mineral wool insulation + airtightness, moisture control. 5 Good practice details: Concrete tiles or natural slates (air-open) Slating laths Counter battens (for roof drainage) LR (breathable) roofing felt Full fill ISOVER Metac insulation Vario KM Duplex or XtraSafe Intelligent Airtightness VCL Composite PIR thermal laminate by others* Fibre cement slates (air-closed) Slating laths Counter battens (provides ventilation space) LR (breathable) roofing felt Full fill ISOVER Metac insulation Vario KM Duplex or XtraSafe Intelligent airtightness VCL Composite PIR thermal laminate by others* Concrete tiles or natural slates (air-open) Slating laths LR (breathable) roofing felt Full fill ISOVER Metac insulation Vario KM Duplex or XtraSafe Intelligent airtightness VCL Composite PIR thermal laminate by others* Concrete tiles or natural slates (air-open) Slating laths LR (breathable) roofing felt Full fill ISOVER Metac insulation Vario KM Duplex or XtraSafe Intelligent airtightness VCL Composite PIR thermal laminate by others* *Maximum R-value = 1/3 of total Roof insulation. Pitched Roof Solutions
8 Pitched Roof Solutions 6 Pitched Roofs Pitched Roof insulation full filled between rafters + Vario If renovating or converting your attic, Metac easily exceeds renovation regulations! 1 Tiled or slated roof with external counter battens/ ventilation space* 2 ISOVER breathable felt Ecran ISOVER insulation installed between rafters 4 Vario membrane + tapes mm Gyproc WallBoard * Even in instances where there is no external counter batten/ventilation space Metac can still be full filled once used with XtraSafe. Contact our Technical department for more information. 5 4 Insulation in rafters mm Airtightness/Moisture Control Board lining U-value W/m 2 K Metac 180 Vario membrane + tapes 12.5mm Gyproc WallBoard 0.22 Metac 220 Vario membrane + tapes 12.5mm Gyproc WallBoard 0.16 Metac 300 Vario membrane + tapes 12.5mm Gyproc WallBoard 0.13 ISOVER PRODUCTS Metac Roll + Vario System
9 7 Pitched Roof with Internal Counter Batten Insulation full filled between rafters + Vario + internal counter battens 1 Tiled or slated roof with external counter battens/ ventilation space* 2 ISOVER breathable felt Ecran 3 ISOVER insulation installed between rafters 1 4 Vario membrane + tapes 5 ISOVER insulation between counter battens 6 Gyproc WallBoard * Even in instances where there is a non permeable roof finish (fibre cement slates) and no external counter batten/ventilation space Metac can still be full filled once used with XtraSafe. Contact our Technical department for more information. 6 Insulation in rafters mm Insulation in counter batten Airtightness/Moisture Control Board lining U-value W/m 2 K Metac 150 Metac 50 Vario membrane + tapes 12.5mm Gyproc WallBoard 0.18 Metac 180 Metac 50 Vario membrane + tapes 12.5mm Gyproc WallBoard 0.16 Metac 220 Metac 50 Vario membrane + tapes 12.5mm Gyproc WallBoard 0.14 ISOVER PRODUCTS Metac Roll + Vario System Pitched Roof Solutions
10 Pitched Roof Solutions 8 Pitched Roof with Calibel Insulation full filled between rafters + Vario + Calibel ISOVER s Roof Solution is the best possible option to protect timber roof structures, Metac insulation can be fully filled in rafters even in non breathable roof structures the Safer option! When used with Calibel laminate it offers a fully breathable solution with moisture protection for the building fabric! 1 Tiled or slated roof on tiling battens 2 ISOVER breathable felt Ecran 3 ISOVER insulation installed between rafters 1 4 Vario XtraSafe membrane and tapes 5 ISOVER Calibel Insulation in rafters mm Airtightness & moisture control layer Thermal laminate U-value W/m 2 K Metac 150 Vario XtraSafe 42.5 Calibel 0.20 Metac 150 Vario XtraSafe 62.5 Calibel 0.18 Metac 180 Vario XtraSafe 62.5 Calibel 0.16 Metac 220 Vario XtraSafe 62.5 Calibel 0.14 ISOVER PRODUCTS Metac Roll + + Calibel Board Vario System
11 9 Pitched Roof with Thermal Laminate Insulation full filled between rafters + Vario + Thermal Laminate ISOVER Metac can be full filled between rafters with Vario KM Duplex and a thermal laminate, where there are air-open tiles/slates with no counter battens/ventilation space on outside roof structure. 1 Air-open tiles/slates on tiling battens (no ventilation space/ counter-battens) 2 ISOVER breathable roof membrane 1 3 ISOVER insulation installed between rafters 4 Vario KM Duplex membrane and tapes Thermal Laminate If installing in a closed roof construction i.e. Fibre Cement roof tiles with no counter battens on exterior, a 50mm ventilation space must be left between insulation and roof membrane. 4 5 Insulation in rafters mm Airtight layer only Thermal laminate U-value W/m 2 K Metac 150 Vario KM Duplex 32.5mm Thermal laminate 0.20 Metac 150 Vario KM Duplex 42.5mm Thermal laminate 0.18 Metac 150 Vario KM Duplex 62.5mm Thermal laminate 0.15 Metac 180 Vario KM Duplex 72.5mm Thermal laminate 0.13 Metac 220 Vario KM Duplex 72.5 Thermal laminate 0.11 * Refers to a rigid foam insulation material and a 12.5mm plasterboard, please refer to manufacturers guidelines for performance. ISOVER PRODUCTS Metac Roll + Vario System Pitched Roof Solutions
12 Pitched Roof Solutions 10 Installation Pitched Roof Measure depth and width of rafters. Then measure the length and width of the building and multiply twice the span of the rafters by the length of the building. Lift Metac into the attic still in its packaging. Measure and cut the roll to fit rafter width leaving 10mm extra on dimension. Unroll and allow full recovery, use a straight edge and sharp insulation knife. Push and friction fit between rafters, keeping flush with rafters. Ensure eaves ventilation is left where required. Metac can be fully filled* between rafters when used with our Vario XtraSafe membrane installed below the insulation with Gyproc Plasterboard to complete the installation - this provides the safest solution to protect timber rafters from moisture damage. To increase the u Value Isover recommends installing 50 x 50mm counter battens filled with 50mm Metac this allows a service zone without need to pierce airtight membrane. Finally use Gyproc plasterboard applied to counter battens to complete the installation. WANT TO KNOW MORE?
13 Technical Academy 11 Technical Training Looking for Technical Advice? Need Training on ISOVER Systems? Practical hands on training & theory courses ISOVER Multi Comfort House; A guide to passive house building in Ireland. Insulation, an overview; theory & practical. A guide to ISOVER insulation systems and on-site practices. Airtightness and moisture management; theory, systems & on-site solutions. Technical advice provided on: Low energy / passive house building. U-Value calculations. Condensation risk analysis. Thermal bridge support and advice. On-site support and detailing. Dry lining & moisture management; theory, systems & on-site solutions. Roof insulation; theory, systems & on-site solutions. Call our Technical Team on today tech.ie@saintgobain.com Pitched Technical Roof Solutions Training
14 Pitched Roof Solutions 12 ISOVER Metac Roll high performance rafter insulation A high performance quality thermal insulation roll designed for a wide range of applications where space is at a premium. PRODUCT FEATURES Thermal Conductivity W/mK Excellent Acoustic Performance Excellent Fire Safety - A1 Fire Rated Vapour permeable breathable insulation Improves energy performance and reduces heating & cooling costs Easy to install. Friction fits between timber stud, joists and rafters with no need for additional fixings Made from recycled glass. Minimal manufacturing and on-site wastage. Low carbon footprint at manufacture and during transport W/mK Product Thickness (mm) Width (mm) Length (mm) Pack Area (m 2 ) Pack Per Pallet Metac G3 Touch Metac G3 Touch Metac G3 Touch Metac G3 Touch x Metac G3 Touch Metac G3 Touch x Metac G3 Touch WHERE TO USE Pitched Roof - Rafters Walls - Internally insulated
15 13 ISOVER Vario System high performance airtightness & moisture control A high performance system consisting of intelligent membranes and accessory products, providing excellent levels of airtightness with unparalleled protection against moisture. PRODUCT FEATURES High performance airtightness and moisture control system Two intelligent membranes to suit a variety of applications Range of accessory products - high performance tapes and sealants Xtra system with easy installation apply and release function no staples required. Product Width (mm) Length (mm) Packaging ISOVER Vario KM Duplex Membrane m 2 / roll ISOVER Vario KB1 Single sided tape rolls = 200 m ISOVER Vario DoubleFit Mastic n/a 310ml 12 cartridges ISOVER Vario MultiTape SL rolls = 250 m ISOVER Vario Protape rolls = 50 m Ecran Integra Roof membrane m 2 /roll ISOVER Vario Xtra Safe Membrane 1.5m m 2 / roll ISOVER Vario Xtra Fix Strip 10mm rolls per pack WHERE TO USE Airtightness Pitched Roof Solutions
16 ISOVER Ireland Unit 4, Kilcarbery Business Park, Nangor Road, Dublin 22 Tel: +353 (0) ISOVER Technical Team ROI Free Phone: NI Phone:
Multi-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
More informationENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.
APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)
More informationAirtight Intelligence
VARIO - Airtight Intelligence The multitasking membrane The Vario System keeps heat in Airtight Intelligence Vario-System keeps draughts out beats present and future regulations saves energy Introducing
More informationRockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
More informationTimber Frame Walls Rethinking Construction
Insulation Fifth Issue November 2007 Timber Frame Walls Rethinking Construction INSULATION BEST PRACTICE FOR THE 21ST CENTURY Summary 9 mm OSB sheathing 3 mm skim coated 15 mm plasterboard Rock or glass
More informationSection 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining
Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationGUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.
GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part
More informationContents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37
Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details
More informationBuilding Regulations for the Conservation of Fuel and Power
Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction
More informationSection 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
More informationThe Pocket Guide To Insulation August 2013
The Pocket Guide To Insulation August 2013 Introduction Knauf Insulation is the UK s leading manufacturer of insulation products, including: Earthwool glass and rock mineral wool Polyfoam ECO extruded
More informationMulti-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX
Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX TECHNICAL CHARACTERISTICS Multi-Foil Reflective Insulation Xfoil Range of insulation is designed to achieve
More informationSection 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01
Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal
More informationRockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
More informationIncluding. Rubershield-Pro. Breather Membrane
Including RubershieldPro Breather Membrane 2 Ruberoid produces a wide range of underslating membranes, primarily to be installed below tiles, slates or metal roofing providing a secondary barrier against
More informationTwiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India
Twiga Insul India's Leading Thermal and Acoustic Insulation Insulating India Insulating India Twiga is the leading manufacturer of glass wool insulation in India, with a twenty-five year track record of
More informationBER Assessors Dwellings Technical Bulletin
BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED
More informationEnergy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
More informationModule 3.7. Thermal bridging
Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal
More informationRoofers Guide to Underslating Membranes
Roofers Guide to Underslating Membranes IKO is a worldwide enterprise, with more than 3000 employees, and manufacturing plants in Canada, the United States, United Kingdom, Belgium, Holland, France and
More informationIntroduction & Principles Issued in support of Junction Details, Parts 1 to 5
Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction
More informationSteel-framed Walls. Insulation
Insulation A4/8 SF AW1192 Issue 4 Nov 2012 Steel-framed Walls Insulation guide Helps achieve a 6-star house energy rating Rigid and flexible Kingspan AIR-CELL solutions available Vapour barrier or vapourpermeable
More information2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
More informationBUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance
More informationSection 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with
Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and
More informationInnovation - High performance roof, wall and floor insulation board. delivering better performance
2010 VERSION 1 IRL High performance roof, wall and floor insulation board Innovation - delivering better performance PRODUCT SPECIFICATION INSTALLATION GUIDE I ve worked with Xtratherm for years, they
More informationBuilding Control Guidance Note
Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationNRG 75 CRF NRG GREENBOARD WALL SYSTEM
NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark
More informationComposite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
More informationMineral fibreglass insulation
Isover MULTIMAX 30 Specification code: MW - EN 13162 - T5 - MU1 - WS - WL(P) - AF r 5 TeChNICaL SPeCIFICaTION Insulating slabs made of Isover fibreglass wool. The production method is based on the fibering
More informationFERMACELL Powerpanel H 2 O for Wet & Moisture affected areas
FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet
More informationRochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture
Rochdale Building Control Guide Approved Document C Site preparation and resistance to contaminants and moisture Dampness is often misdiagnosed within buildings, the approved document deals with prevention
More information!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
More informationFire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
More informationThe Kingspan Insulation Price List 1 st January 2013
Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings
More informationA COMPREHENSIVE GUIDE TO THIN MULTIFOIL INSULATION
2011 Edition ACTIS THIN MULTIFOIL INSULATION A COMPREHENSIVE GUIDE TO THIN MULTIFOIL INSULATION Product Catalogue ROOFS ATTICS FLOORS WALLS EUROPEAN TECHNICAL APPROVAL IN PROCESS Registration N 12.01/12
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationUbiflex. Non-lead flashing system
Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof
More informationROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS
Mercury Building Products Ltd 114 Eckington Road Coal Aston Dronfield Sheffield S18 3AY Tel: 01246 292816 Fax: 01246 292867 e-mail: sales@vaprfree.co.uk danny@vaprfree.co.uk website: www.mercurybuildingproducts.com
More informationPart 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery
Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6
More informationRev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org
Rev 1-12.2013 Code of Practice SIP Technology www.uksips.org What are Structural Insulated Panels (SIPS)? SIPS are prefabricated, high performance, lightweight, building panels that can be used in floors,
More informationManual lifting and handling
Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details
More informationThe WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check
More informationResidential Refurbishment. September 2012. ThermoShell Internal Wall Insulation System Design Guide
Residential Refurbishment September 2012 ThermoShell Internal Wall Insulation System Design Guide The importance of wall insulation in houses Buildings account for 40% of our energy consumption and in
More informationSTEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope
STEEL BUILDINGS IN EUROPE Single-Storey Steel Buildings Part 8: Building Envelope Single-Storey Steel Buildings Part 8: Building Envelope 2 - ii Part 8: Building Envelope emissions
More informationThe Case for Cross Laminated Timber: Part 2
Learning Objectives The Case for Cross Laminated Timber: Part 2 Opportunities and Challenges for a New Class of Timber Product 1. Review answers to common questions regarding the design and construction
More informationINSULATED PITCHED ROOFING
DOW CONSTRUCTION PRODUCTS (a division of the Dow Chemical Company Ltd) INSULATED PITCHED ROOFING Welcome to this RIBA approved CPD self tutorial. First some information about the Dow Chemical Company itself:
More informationImproving thermal insulation of concrete sandwich panel buildings
Improving thermal insulation of concrete sandwich panel buildings Jørgen Munch-Andersen Danish Building Research Institute, Aalborg University LCUBE conference, Vienna 17-18 April 2007 Outline A general
More informationEcoTouch Insulation with PureFiber Technology
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
More informationFire Resistant Systems
Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant
More informationTP10. Insulation RAFTER LEVEL INSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACES BBA BRITISH
Insulation CI/Sfb (27.9) Rn7 M2 Fifth Issue May 2007 TP10 RAFTER LEVEL INSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACES High performance rigid urethane insulation thermal conductivity 0.023 W/m.K
More informationWe care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview
http://upload.wikimedia.org/wikipedia/commons/a/ae/flag_of_the_united_kingdom.svg.0.0 :8 Seite von Environmentally-Friendly Building Products from Renewable Resources Product range overview We care about
More informationDELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
More informationEnvelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
More informationROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.
Rigid, Semirigid and Flexible Slabs Versatile thermal acoustic insulation slabs ROCKWOOL are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. They are manufactured
More informationIf you are a web registered user of ArlingontPermits.com you may also request an inspection at:
TECHNICAL BULLETIN Community Development & Planning, Building Inspections TOPIC: Permits & Inspections for Roofing Replacement Effective November 1, 2011 Revised This Technical Bulletin will provide contractors
More informationHow To Certify The Scottsdale Construction System
BRE CERTIFICATION LIMITED PRODUCT SCOTTSDALE CONSTRUCTION SYSTEM CERTIFICATE NUMBER 129/07 DATE OF ISSUE December 2007 SUPPLIED BY Scottsdale Construction System Ltd SUMMARY The Scottsdale Construction
More informationKnauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap
Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet
More informationBuilding Control Guidance Note
Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you
More informationCERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES
CERTIFICATE OF APPROVAL No CF 5055 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 1 st Industrial Area,
More informationWestern Red Cedar Shingles Product Guide
Western Red Cedar Shingles Product Guide Western Red Cedar Shingles & Shakes from John Brash are a truly renewable and sustainable roofing and cladding material; with one of the lowest carbon footprints
More informationConservatory warm roof conversion system
Conservatory warm roof conversion system IS YOUR EXISTING CONSERVATORY ROOF: Too hot in summer or too cold in winter? Waste of valuable living space? Unable to relax to watch TV? Transform your conservatory
More informationRoof Insulation Building. Energy. Environment friendly e-library
Roof Insulation Building Codes & Energy Efficiency Environment friendly e-library Building Code Driver Buildings consumer almost 50% of all energy. Experts believe that a 30% increase in building efficiency
More informationUpstand Rooflight Natural Light Translucent Upstand Systems
Insulated Panels CI/SfB (4-) Rh2 October 2008 ROOFLIGHT SYSTEM Upstand Rooflight Natural Light Translucent Upstand Systems Upstand Rooflight Pre-assembled Rooflight System Introduction The Upstand Rooflight
More informationConfort 160. Sliding Systems. Sapa Building System
Confort 160 Sliding Systems Sapa Building System Confort 160 is a high performance thermally insulated sliding window system, with a user-friendly slide action. The system, which has an attractive aesthetic
More informationProRox Slabs (formerly known as RW slabs)
Slabs (formerly known as RW slabs) Versatile thermal acoustic insulation slabs ROCKWOOL's Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. They are
More informationI n s u l a t i o n. Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (47) Ln6 Sixth Issue March 2011 BREATHABLE MEMBRANE FOR UNVENTILATED PITCHED ROOFS AND TIMBER FRAME WALLS Waterproof can be used as a temporary roof covering Non tenting Airtight
More informationThe WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step
More informationThe Pleasance, Edinburgh
Refurbishment Case Study 5 DRAFT The Pleasance, Edinburgh Insulation of coom ceiling, attic space & lightwell 2 nd edition The views expressed in commissioned case studies are those of the authors and
More informationEnergy Efficient Windows
Energy Efficient Windows All properties lose heat through their windows. But energy-efficient glazing keeps your home warmer and quieter as well as reducing your energy bills. That might mean double or
More informationGYPSUM AREA SEPARATION FIREWALLS GA-620-2011
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein
More informationAbstract. 2. Cold Pitched Roofs
Heat and moisture transport between houses and cold lofts - a combination of convection and diffusion Emannuel Essah and Chris Sanders Glasgow Caledonian University Abstract About 80% of domestic pitched
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More information- Version 2 Total R-value calculations for typical building applications
- Version 2 Total R-value calculations for typical building applications - Version 2 Total R-value calculations for typical building applications Acknowledgements Version Date Description 1 Nov 2010 Initial
More informationCardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com
CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can
More informationCITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
More informationThe Real Value of Space
Insulation First Issue May 2015 The Real Value of Space IN COMMERCIAL REAL ESTATE THE IMPACT OF DIFFERING INSULATION SPECIFICATIONS ON THE ROI ASSOCIATED WITH INTERNAL FLOOR AREA Find additional space
More informationFLAT ROOF INSULATION INSULATION ROOFING FLAT. Quick Guide. Quick Guide. Insulation. EcoTherm Insulation UK Sales Team. Insulation
Insulation Insulation Scotland & North England 07824 412579 North West & North Wales 07931 342948 South Wales & West Midlands 07940 546247 Yorkshire & East Midlands 07825 570100 FLAT ROOF INSULATION EcoTherm
More informationEuropean Technical Approval ETA 13/0526
European Technical Approval ETA 13/0526 Trade Name Holder of the approval Website Generic type and use of construction product DOLCEA i3 PCIM S.A. Rue du Péquet 54 5590 Achene (Ciney) Belgium www.isoproc.eu
More informationSample Drawing Package for One and Two Family Dwelling Applications
Sample Drawing Package for One and Two Family Dwelling Applications For a full list of submission requirements, refer to the relevant checklist for your application found on our website: http://vancouver.ca/home-property-development/application-forms-and-checklists.aspx
More informationCHESTERFLEX ROOF WATERPROOFING MEMBRANES
CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED
More informationKINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION
Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: general.enquiries@kil.kingspan.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL
More informationInsulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW
Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They
More informationPB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection
PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,
More informationProviding protection in construction
Providing protection in construction VOLUME 2: WALLS AND FLOORS Contact Information UK office address: DuPont Tyvek Hither Green Trading Estate Clevedon, North Somerset BS21 6XU Tel: 01275 879770 Fax (sales):
More informationThermal Performance of Steel Beam Junctions using Different Connection Methods
Modern methods of construction and prefabrication Sustainable building design Construction and life cycle costing Steel, concrete, timber, masonry and glass construction Construction design guidance and
More informationInterior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer
More informationBuilt-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5
Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,
More informationHow To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
More informationIRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION
IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION Bill Robinson BSc. C. Eng. M. I. Struct. E. Timber Design Services 1 IS440 Timber frame
More informationSIP (STRUCTURAL INSULATED PANEL)
SIP (STRUCTURAL INSULATED PANEL) KINGSPAN TEK ACORN SIP ABSTRACT BUILDING SERVICES Ltd Kingspan TEK is the manufacturer and supplier of the panels and components. Acorn SIP are the Architects who individually
More informationCupa Natural Slate Roofing design and fixing guide
Cupa Natural Slate Roofing design and fixing guide Cupa Natural Slate synonymous with quality Currently the Spanish slate industry is the undisputed market leader in natural slate production, with 90%
More informationThe ISOVER System for Airtightness and Moisture Protection
The ISOVER System for Airtightness and Moisture Protection Introduction Today s modern housing needs to provide much more than basic shelter from the elements it must offer high standards of quality and
More informationfire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors
fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors Roxul Safe n Sound Sound Control and Fire Safety From One Batt Insulation Roxul
More informationPrefabricated building PVC vertical sliding window
Prefabricated building PVC vertical sliding window SLOVENSKO ITALIA ESPAÑA ITALIA The company, we have the pleasure to introduce in this brochure, is an important and dynamic industrial company located
More informationTR31. I n s u l a t i o n. Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Sixth Issue March 2011 TR31 STRUCTURAL INSULATION / FSC CERTIFIED PLYWOOD COMPOSITE FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT UP FELT High performance
More informationMONARPERM 600, MONARPERM PLUS AND MONARPERM TOP (COLD VENTILATED AND WARM NON-VENTILATED)
Icopal Limited Barton Dock Road Stretford Manchester M32 0YL Tel: 0161 865 4444 Fax: 0161 866 9859 e-mail: info.uk@icopal.com website: www.icopal.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL
More information